TRITON PATRIOT

TRITON PATRIOT is a 1969 offshore supply vessel. The Coast Guard has recorded 70 inspections since 1983, most recently in October 2025, along with 95 deficiencies, 1 operational control and 5 casualty investigations between 2002 and 2025.

Records from 1983 to 2025. Most recent: inspection, 8 October 2025.

Built
1969
Last inspected
8 October 2025
Documentation
Valid · documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

7030731 View on MarineTraffic leaves Maury; a third-party site, nothing from it is stored here
WDL4381
Flag
UNITED STATES
368027980
Maury page id
psix-54754

Inspections, by type

…with no type recorded24
Years with a record 32 calendar years (1983–2025)
The 70 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Offshore class in Maury's sources begin in 1978.

Documentation record

Registered dimensions (L × B × D)156.6 ft × 38.0 ft × 13.0 ft
Registered tonnagegross 145 / net 98
ITC dimensions (L × B × D)156.6 ft × 38.0 ft × 13.0 ft
ITC tonnagegross 713 / net 213
BuilderAMERICAN MARINE CORP · NEW ORLEANS, LA, UNITED STATES · built 1969
Hull materialSteel
PropulsionDiesel Reduction
Hull shapeNot recorded
Hull configurationNot recorded
Hailing portMORGAN CITY, LA
Trade endorsementsCoastwise, unrestricted, Registry
DocumentationValid · issued 24 April 2026 · expires 30 April 2027
Service, as the file records itOffshore Supply Vessel
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it213 - Convention (Subpart B), Net Ton
98 - Regulatory (Subpart C or D), Net Ton
713 - Convention (Subpart B), Gross Ton
145 - Regulatory (Subpart C or D), Gross Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 September 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.

Radio station licence

WDL4381MMSI 368027980 · active · compulsorily equipped · granted 5 February 2020, expires 5 February 2030
WDK7031MMSI 368027980 · cancelled · compulsorily equipped · granted 9 March 2019, cancelled 3 February 2020
WDJ9642MMSI 368027980 · cancelled · compulsorily equipped · granted 20 March 2018, cancelled 27 February 2019 · licensed under a name not among this hull’s recorded names (not shown)
WDH6087MMSI 366802920 · expired · compulsorily equipped · granted 30 July 2014, cancelled 5 October 2024 · licensed under a name not among this hull’s recorded names (not shown)
WDA3846MMSI 366802920 · cancelled · compulsorily equipped · granted 11 January 2011, cancelled 28 July 2014
WDA2367MMSI not assigned · expired · voluntarily equipped · granted 26 September 2000, cancelled 27 November 2010
WCY9325MMSI not assigned · expired · voluntarily equipped · granted 10 March 1999, cancelled 16 May 2009 · licensed under a name not among this hull’s recorded names (not shown)
FCC Universal Licensing System ship-station file of 6 September 2026, matched to this hull on its US Official Number. Status and dates are the file’s own. The licensee is not read from the file and is not shown. A lapsed licence’s MMSI is still the number the vessel transmitted under while it was valid.

Inspected as a tow unit · 1

The Coast Guard recorded this vessel and the following in the same inspection activity — normally a tug and the barges in its tow. A recreational or unclassed hull in the same activity is held and not published, so it does not appear here: these lists are a floor, not a complete manifest.

WILLOW RIVER Offshore Supply Vessel · MISLE 293799 · 9 April 2002 · activity 1612082

Inspection history · 70

8 October 2025 Annual Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 8248940
26 April 2025 Damage Survey
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 8120734
26 April 2025 Type not recorded
No type recorded · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 8128813
24 February 2025 Internal Structural Exam · Drydock Exam
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 8083422
21 May 2024 Annual Inspection · Deficiency Check
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 7916179
7 March 2024 In-Service Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 7875737
31 October 2023 Damage Survey
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 7818626
30 October 2023 Type not recorded
No type recorded · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 7820801
26 April 2023 Drydock Exam · Internal Structural Exam
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 7675791
3 February 2023 Drydock Extension
Administrative · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 7644064
11 May 2022 Annual Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 7448203
4 March 2021 Periodic Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 7150613
6 January 2021 Administrative Inspection
Administrative · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 7120479
11 March 2020 Administrative Inspection · Commercial Dive Inspection · Annual Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 6924475
18 February 2020 Administrative Inspection · Hull Examination · Drydock Exam · Internal Structural Exam
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 6910481
20 August 2019 In-Service Inspection · Annual Inspection · Administrative Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 6789725
15 April 2019 Administrative Inspection
Administrative · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 6663080
4 September 2018 Type not recorded
No type recorded · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 6531529
23 May 2018 COI Inspection · Administrative Inspection · Commercial Dive Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 6422161
9 April 2018 Administrative Inspection · Hull Examination · Drydock Exam · Internal Structural Exam
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 6388149
19 October 2017 Administrative Inspection
Administrative · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 6291211
30 March 2016 Drydock Extension · Administrative Inspection
Administrative · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 5844341
20 October 2015 Annual Inspection · Commercial Dive Inspection · MTSA/ISPS Verification
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 5747536
12 June 2014 Administrative Inspection · Deficiency Check · Internal Structural Exam · COI Inspection · MTSA Verification · Hull Examination
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 4887790
25 March 2009 Re-Inspection · Commercial Dive Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 3454384
30 July 2008 Internal Structural Exam · Drydock Exam · MTSA Verification
Physical examination · Marine Safety Unit Port Arthur · USCG Heartland District (CGD-H) · Activity 3228909
23 May 2008 Periodic Inspection · MTSA Verification
Physical examination · Marine Safety Unit Lake Charles · USCG Heartland District (CGD-H) · Activity 3214745
12 March 2007 MTSA Verification · Re-Inspection · Examination of Repairs
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 2886109
7 April 2006 Internal Structural Exam · Commercial Dive Inspection · Hull Examination
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 2616667
27 February 2006 COI Inspection
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 2591492
23 February 2006 Drydock Extension
Administrative · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 2590596
13 October 2005 Damage Survey
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 2513953
12 October 2005 Type not recorded
No type recorded · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 2513033
26 May 2005 Re-Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 2368191
19 July 2004 Deficiency Check
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 2138601
16 July 2004 MTSA Verification
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 2135348
28 May 2004 Re-Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 2080644
20 July 2003 Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1860779
10 June 2003 Re-Inspection · Hull Examination
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1802439
5 March 2003 Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1753037
6 July 2002 Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1645241
30 May 2002 Annual Inspection
Physical examination · MIDET HARVEY CANAL DETAIL · USCG Heartland District (CGD-H) · Activity 1622704
9 April 2002 Damage Survey
Physical examination · MIDET HARVEY CANAL DETAIL · USCG Heartland District (CGD-H) · Activity 1604113
9 April 2002 Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1612082
1 March 2001 Hull Examination · COI Inspection
Physical examination · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 1457904
1 September 2000 Inclining Experiment · COI Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1399490
30 November 1999 Type not recorded
No type recorded · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 766225
10 November 1999 Type not recorded
No type recorded · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 810327
9 November 1999 Type not recorded
No type recorded · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 211526
1 November 1999 Deficiency Check
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 803385
10 August 1999 Type not recorded
No type recorded · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 496940
5 August 1999 Re-Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1391076
6 August 1998 COI Inspection · Hull Examination
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1438783
7 August 1996 Type not recorded
No type recorded · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 667084
27 July 1996 Type not recorded
No type recorded · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 393733
22 July 1996 Type not recorded
No type recorded · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 44343
21 October 1994 Type not recorded
No type recorded · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 667085
18 September 1994 Type not recorded
No type recorded · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 1180688
8 April 1994 Uninspected Other
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1354672
18 March 1994 Type not recorded
No type recorded · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 212513
18 March 1994 Type not recorded
No type recorded · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 231087
15 September 1992 Type not recorded
No type recorded · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 21582
10 July 1987 Administrative
Administrative · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1321582
8 March 1987 Administrative
Administrative · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1331369
2 February 1987 Administrative
Administrative · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1003572
26 February 1986 Re-Inspection
Physical examination · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 997063
8 March 1985 Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1287390
15 October 1984 Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1282560
19 April 1984 Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 973099
24 February 1983 Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 966074

Deficiency record · 95

13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 8 October 2025 Resolved
The inspection for certification shall insure that the vessel’s main and auxiliary machinery, is in satisfactory condition and fit for the service for which it is intended. -Starboard main engine had continuous oil leak on the outboard side while online. -Starboard generator governor failed once generators were paralleled resulting in a loss of power. 46 CFR 126.430
Action required: 60 - Rectify deficiencies prior to movement
Due 8 October 2025
Resolved 10 October 2025
Resolution: Tested port generator twice, starting generator and taking the load. Added technician report to documents.
02 - Structural Conditions › N/A - No Subsystem › Stability/strength/loading information and instruments
Issued 8 October 2025 Resolved
The vessel's stability letter sets forth conditions of operation. The stability letter states that the bilges and voids shall be kept pumped to minimum content at all times and draft shall not exceed 11 feet. -Engine room bilges were filled with excessive water and oil. - Passage way to engine room has excessive oily water. - MI's unable to verify stern draft marking. 46 CFR 170.120(a)
Action required: 17 - Rectify deficiencies prior to departure
Due 8 October 2025
Resolved 9 October 2025
Resolution: The excessive engine room oil/ water, and passageway oil/ water were removed via vacuum truck (2,000 gal). The stern draft marking was visible, drafting 10’ 6”
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 8 October 2025 Resolved
Electric installations on vessels must ensure protection of crew, other persons, and the vessel from electrical hazards. Machinery space had numerous motor controllers, electrical containments, outlet faceplates & dead end wires which were not properly secured and exposed the electrical equipment as a hazard. 46 CFR 111.01
Action required: 16 - Rectify deficiencies w/in 14 days
Due 22 October 2025
Resolved 10 October 2025
Resolution: Witnessed all electrical deficiencies repaired.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 8 October 2025 Resolved
The inspection for certification shall be such as to insure that the vessel’s main and auxiliary machinery, is in satisfactory condition and fit for the service for which it is intended. Port main engine’s RPM gauge was non-functional at the time of inspection and "T" handle to access fuel shut off valve was missing. 46 CFR 126.430
Action required: 16 - Rectify deficiencies w/in 14 days
Due 22 October 2025
Resolved 9 October 2025
Resolution: The port MDE gauge was found functional, and a ‘t’ handle to access the remote fuel shuts was obtained and put into place.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 8 October 2025 Resolved
Each battery must be secured to protect against shifting or vibration of the vessel, and free from exposure to splash or spray of water. 02 batteries in the engine room did not have covers protecting them and 01 battery in the steering gear room was unsecured. 46 CFR 129.350(b)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 22 October 2025
Resolved 10 October 2025
Resolution: Batteries bolted and properly secured.
11 - Life Saving Appliances › N/A - No Subsystem › Launching arrangements for rescue boats
Issued 8 October 2025 Resolved
Each fall used with a launching appliance must be renewed either when necessary because of deterioration or after the passage of not more than 5 years, whichever occurs earlier. -Vessel did not documentation for last weight test for davit. 46 131.550(b)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 22 October 2025
Resolved 9 October 2025
Resolution: Documentation was provided.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 8 October 2025 Resolved
Each portable or temporary electric cord must be constructed and used in compliance with the requirements of 46 CFR 111.60-13. The extension cord ran though the PVHO room to supply power to deep freeze should be removed and the deep freeze connection made to a permanent outlet. 46 CFR 129.340(q)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 22 October 2025
Resolved 9 October 2025
Resolution: The extension cord had been removed, and an outlet added with the deep freeze plugged directly into the outlet.
08 - Alarms › N/A - No Subsystem › Steering gear alarm
Issued 8 October 2025 Resolved
Visible and audible alarms must be installed at the pilothouse to indicate loss of power to the steering motor or for control of the main steering gear. This indicator for the #02 steering motor was extinguished. 46 CFR 130.460
Action required: 50 - Rectify deficiencies w/in 30 days
Due 7 November 2025
Resolved 9 October 2025
Resolution: Verified that the visual indicator for the 02 steering motor was operable. The steering gear pump run indicators were also made operable.
11 - Life Saving Appliances › N/A - No Subsystem › Rescue boats
Issued 8 October 2025 Resolved
Each propeller on a rescue boat must be fitted with a propeller guard with a maximum opening of 3in. on all sides on which a person is likely to be exposed. -The rescue boat did not have a propeller guard. 46 CFR 133.135(a)46 CFR 160.156-7(11)
Action required: 50 - Rectify deficiencies w/in 30 days
Due 7 November 2025
Resolved 15 October 2025
Resolution: Received photo of gurad installed.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 8 October 2025 Resolved
Inspections of lifesaving equipment shall be carried out during each inspection to include the proper condition of flotation equipment such as lifebuoys. A starboard lifebuoy and light were found zip tied to deck railing and should be properly remounted and in IAW the general arrangement plan. 46 CFR 133.45 (b)
Action required: 50 - Rectify deficiencies w/in 30 days
Due 7 November 2025
Resolved 9 October 2025
Resolution: The starboard lifebuoy found zip tied was properly remounted.
11 - Life Saving Appliances › N/A - No Subsystem › Rescue boats
Issued 8 October 2025 Resolved
The following must be plainly marked or painted on each side of the bow of each rescue boat. The number of persons the boat will hold. The number of persons were not marked on either side of the rescue boat. 46 CFR 131.855(b)
Action required: 50 - Rectify deficiencies w/in 30 days
Due 7 November 2025
Resolved 9 October 2025
Resolution: Both sides of the rescue boat were marked with the total number of persons.
05 - Radio Communications › N/A - No Subsystem › MF/HF Radio installation
Issued 8 October 2025 Resolved
Each vessel must comply with 47 CFR part 80. Based on route, vessel must have a DSC-capable single sideband (SSB) radiotelephone or MF/HF radio. Vessel is not equipped with either. 46 CFR 130.210
Action required: 50 - Rectify deficiencies w/in 30 days
Due 7 November 2025
Resolved 9 October 2025
Resolution: A third party technician (Rhodes Marine) installed an MF/HF radio. GPS & MMSI were input, and the radio operable on e-power.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Doors
Issued 8 October 2025 Resolved
A Class-1 door may be installed if the vessel’s pilothouse contains a visual indicator showing the door open or closed. Not indicators were on the bridge. 46 CFR 174.210(c)
Action required: 50 - Rectify deficiencies w/in 30 days
Due 7 November 2025
Resolved 10 October 2025
Resolution: 02 sensors were added. Indicator on bridge worked properly.
04 - Emergency Systems › N/A - No Subsystem › Water level indicator
Issued 8 October 2025 Resolved
Visible and audible alarms must be installed at the pilothouse to indicate high bilge-level alarms. The alarm for the starboard machinery space was found inoperable but was renewed during MI attendance and verified in satisfactory operation. 46 CFR1 30.460
Action required: 10 - Deficiency Rectified
Due 8 October 2025
Resolved 8 October 2025
Resolution: The alarm for the starboard machinery space was found inoperable but was renewed during MI attendance and verified in satisfactory operation.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 27 April 2025 Resolved
Electrical equipment on a vessel must be designed, installed, and maintained to provide services necessary for safety under normal and emergency conditions. Vessel experienced a complete loss of power. 705- Vessel must transit under tow to Port Fourchon to undergo damage assessment and repair. Vessel may not depart Port Fourchon until OCMI inspector has cleared the deficiency.
Action required: 705 - Other - as specified
Resolved 28 April 2025
Resolution: Vessel rep emailed a technician report for a new mag pick up for port generator and a new headgasket on stbd generator.
11 - Life Saving Appliances › N/A - No Subsystem › Rescue boats
Issued 21 May 2024 Resolved
Each OSV must carry at least one rescue boat that is approved under series 160.156. Vessel did not have CG approved rescue boat onboard. Rescue Boat servicing records reflected that of another rescue boat that was onboard the vessel in the past. Vessel also did not have required equipment onboard the rescue boat. Vessel must install approved rescue boat with required equipment.
Condition: Invalid
Action required: 17 - Rectify deficiencies prior to departure
Resolved 22 May 2024
Resolution: Approved Rescue boat onboard and tested.
10 - Safety of Navigation › N/A - No Subsystem › Bridge operation
Issued 21 May 2024 Resolved
After loading, but before departure, and at other times necessary to assure the safety of the vessel, the master shall verify that the vessel complies with requirements in it's stability letter. The vessel may not leave port until it is in compliance with it's stability letter. Vessel's stability letter stated that their current draft shall not exceed 11 feet, however draft readings were 11'0 (forward) and 11'7 (aft).
Condition: Placed in Improper Service
Action required: 17 - Rectify deficiencies prior to departure
Resolved 22 May 2024
Resolution: Verified drafts were in compliance with the Stability letter.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Doors
Issued 21 May 2024 Resolved
Class-1 watertight doors shall be able to withstand a head of water equivalent to the depth from the sill of the door to the bulkhead deck. The four watertight doors in the engine room (forward, port, starboard, and rudder room) were out of adjustment and could not close water- tight.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 22 May 2024
Resolution: Verified WTD's sealed.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Machinery space openings
Issued 21 May 2024 Resolved
Bulkheads in each machinery space must be watertight. Shore tie power cable is run through the starboard side bulkhead of the engine room and the penetration is not watertight.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 22 May 2024
Resolution: Verified opening sealed.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 21 May 2024 Resolved
Each OSV must be equipped with portable fire extinguishers. Portable fire extinguisher in the forward port side of the engine room were missing.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 22 May 2024
Resolution: Verified extinguiser in place.
10 - Safety of Navigation › N/A - No Subsystem › Magnetic compass
Issued 21 May 2024 Resolved
Each vessel must be fitted with a compass suitable for the intended service of the vessel. Except aboard a limited to daytime operation, the compass must be illuminated. Vessel's compass was not illuminated.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Resolved 22 May 2024
Resolution: Light replaced.
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 21 May 2024 Resolved
Each portable fire extinguisher must be marked with a number and its stowage location marked with the same number. Portable fire extinguishers and their locations were not marked.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 22 May 2024
Resolution: Stations and equipmet marked.
07 - Fire Safety › N/A - No Subsystem › Remote Means of control (opening,pumps,ventilation,etc.) Machinery spaces
Issued 21 May 2024 Resolved
Each OSV must have, at the pilothouse, the ability to monitor the pressure in the fire main. Vessel's fire main pressure gauge was inoperable.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 22 May 2024
Resolution: Verified pilothouse gauge operable.
99 - Other › N/A - No Subsystem › Other (MARPOL operational)
Issued 21 May 2024 Resolved
Nothing in this part shall be construed as limiting the inspector from making such tests or inspections as he or she deems necessary to be assured of the safety and seaworthiness of the vessel. Sewage lid at the sewage lift station was not properly sealed.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 22 May 2024
Resolution: Lid sealed.
09 - Working and Living Conditions › 092 - Working Conditions › Other (accident prevention)
Issued 21 May 2024 Resolved
Electrical equipment on a vessel must be designed installed and maintained to protect crew members, offshore workers, and the vessel from electrical hazards, including fire, caused by or originating in electrical equipment and electrical shock. An extension cord was used to power the comms system for the PVHOs.
Condition: Placed in Improper Service
Action required: 17 - Rectify deficiencies prior to departure
Resolved 22 May 2024
Resolution: Outlets installed near devices.
07 - Fire Safety › N/A - No Subsystem › Ventilation
Issued 21 May 2024 Resolved
Vent outlets from all tanks which may emit flammable or combustible vapors must be fitted with a single screen of corrosion-resistant wire. #1, #2 port and #1 stbd vents were missing flame screens.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 22 May 2024
Resolution: Screens put in place.
04 - Emergency Systems › N/A - No Subsystem › Emergency, lighting, batteries and switches
Issued 21 May 2024 Resolved
Emergency lighting must be marked with a letter “E” at least 13 millimeters high. Several emergency lighting fixtures were not marked.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 22 May 2024
Resolution: Verified markings.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 21 May 2024 Resolved
Each distribution panel or switchboard must be totally enclosed, of the dead-end type and if accessible from the rear must be constructed to prevent a person’s accidental contact with energized parts. Engine room switchboard had an exposed panel under the interlock bar and the chamber room distribution panel had two exposed panels.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 22 May 2024
Resolution: Covers installed.
09 - Working and Living Conditions › 091 - Living Conditions › Other (crew and accommodation)
Issued 21 May 2024 Resolved
Ensure that such vessel is equipped with a vessel master key control system, manual or electronic, which provides controlled access to all copies of the vessel’s master key. Vessel currently has locks on doors and a key box on the bridge but does not have a master key control program implemented.46 USC 3106
Condition: Invalid
Action required: 50 - Rectify deficiencies w/in 30 days
Due 21 June 2024
Resolved 18 June 2024
Resolution: Non key type knobs installed.
07 - Fire Safety › N/A - No Subsystem › Remote Means of control (opening,pumps,ventilation,etc.) Machinery spaces
Issued 26 April 2023 Resolved
Fuel shutoff valves would not close. Vessel did not have correct size T-Handle on board and the locations of the shutoffs were not labeled.
Action required: 17 - Rectify deficiencies prior to departure
Due 11 July 2023
Resolved 12 July 2023
Resolution: MI witnessed the valves opening and closing properly. Vessel crew put correct T-Handle in the immediate vicinity of the vaves and properly marked the valves.
04 - Emergency Systems › N/A - No Subsystem › Emergency, lighting, batteries and switches
Issued 26 April 2023 Resolved
04 Emergency lights were inoperable.
Action required: 10 - Deficiency Rectified
Due 11 July 2023
Resolved 11 July 2023
Resolution: Vessel vrew replaced the 04 lights.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 26 April 2023 Resolved
Nonconductive matting was missing from the switchboard.
Action required: 10 - Deficiency Rectified
Due 11 July 2023
Resolved 11 July 2023
Resolution: Vessel rerplaced the matting.
09 - Working and Living Conditions › 092 - Working Conditions › Safe means of access Deck - hold/tank, etc.
Issued 26 April 2023 Resolved
Vessel was missing safety chains on the back deck.
Action required: 17 - Rectify deficiencies prior to departure
Due 11 July 2023
Resolved 12 July 2023
Resolution: Vessel replaced the chains.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 26 April 2023 Resolved
02 fire stations did not have the required spanner wrenches.
Action required: 17 - Rectify deficiencies prior to departure
Due 11 July 2023
Resolved 12 July 2023
Resolution: Vessel rep provided new spanner wrenches for the 02 fire stations.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Auxiliary engine
Issued 4 March 2021 Resolved
Generator prime movers must meet 46 CFR 58.01-5 & 46 CFR 58.1. Stbd generator prime mover had leaking and praying fluid at exhaust manifold. 46 CFR 111.12-1
Action required: 50 - Rectify deficiencies w/in 30 days
Due 4 April 2021
Resolved 8 March 2021
Resolution: Vsl rep provided receipt of new gasket and photo evidence of its install.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 11 March 2020 Resolved
(b) Protect crew members, offshore workers, and the vessel from electrical hazards, including fire, caused by or originating in electrical equipment and electrical shock; the dive shack had a knife edge style switch operating at 400 amps installed without any protective guard. Remove and install proper circuit breaker or install a cover to prevent shock.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 11 April 2020
Resolution: Replaced knife edge with an approved breaker.
11 - Life Saving Appliances › N/A - No Subsystem › Launching arrangements for rescue boats
Issued 11 March 2020 Resolved
(a) Each davit for a rescue boat must be approved under approval series 160.132 with a winch approved under approval series 160.115 (e) Each rescue boat launching appliance must be fitted with a powered winch motor. (f) Each rescue boat launching appliance must be capable of hoisting the rescue boat when loaded with its full rescue boat complement of persons and equipment at a rate of not less than 0.3 meters per second (59 feet per minute). The rescue boat davit is a hand operated davit and winch. Replace davit and winch to ensure it is CG approved under approval series listed above.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 20 November 2020
Resolved 4 March 2021
Resolution: Completed weight test of new davit installation.
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 11 March 2020 Resolved
(4) Nonmetallic flexible hose may be used in lube oil, fuel oil and fluid power systems only where flexibility is required and in lengths not exceeding 30 inches. Several fuel hoses exceeded 30 inches, remove and install hoses 30 inches in length or less.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 11 April 2020
Resolution: Shortened the length of all fuel hoses.
Construction/Loadline › Structures › Scuttle
Issued 30 March 2016 Resolved
Forepeak access scuttle ring needs to be replaced at next DD.
Action required: 705 - Other - as specified
Due 23 June 2016
Resolved 21 August 2019
Resolution: Ring was replaced and inspected.
Communications › Alarms/Indicators › Bilge Alarm
Issued 20 October 2015 Resolved
No bilge alarm in the rudder room
Condition: Invalid
Action required: 15 - Rectify deficiencies by next port
Due 21 October 2015
Resolved 20 October 2015
Resolution: Installed bilge high level sensor in the rudder room
Engineering › Fuel Oil Service System › Piping
Issued 20 October 2015 Resolved
Leaking fuel piping on STBD main engine
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 20 October 2015
Resolved 20 October 2015
Resolution: Leak was repaired
Engineering › Fuel Oil Service System › Piping
Issued 20 October 2015 Resolved
Fuel priming piping required bracketing to stabilize
Condition: Improper Installation
Action required: 17 - Rectify deficiencies prior to departure
Due 20 October 2015
Resolved 20 October 2015
Resolution: Installed appropriate bracketing to secure piping.
Pollution Prevention/Response › Prevention Equipment › Oily Water Separator (15 ppm)
Issued 20 October 2015 Resolved
OWS oil content meter inoperalbe, instructed vessel master not to use OWS until repairs have been made and witnessed by a CG MI.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 21 October 2015
Resolved 30 March 2016
Resolution: Company replaced oil content meter. Witnessed proper operation of OWS.
Fire Fighting › Fixed Fire Detection System › Smoke Detectors
Issued 20 October 2015 Resolved
smoke detectors not operational on bridge and one accomodation space
Condition: Invalid
Action required: 17 - Rectify deficiencies prior to departure
Due 20 October 2015
Resolved 21 October 2015
Resolution: Provided operational smoke detectors.
Lifesaving › Inflatable Liferafts › Hydrostatic Release Unit
Issued 31 July 2014 Resolved
Hydros for liferafts were expired. Renew hydro units on liferafts.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 31 July 2014
Lifesaving › Lifebuoys › Markings (ship name/port)
Issued 31 July 2014 Resolved
Ensure name change is painted on all lifebouys
Due 7 August 2014
Resolved 4 August 2014
Engineering › Pressure Vessel › Maximum Allowable Working Pressure
Issued 12 June 2014 Resolved
Conduct Hydrostatic test on pressure vessels prior to use.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 12 June 2014
Lifesaving › Rescue Boat › Propulsion Engine
Issued 12 June 2014 Resolved
Rescue boat engine would not continue to run under load. Rescue boat is inop.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 5 August 2014
Lifesaving › Line-Throwing Appliances › Lines
Issued 25 March 2009 Resolved
Provide 500' of messenger line for line throwing gun.
Action required: 705 - Other - as specified
Due 25 April 2009
Resolved 25 March 2009
Fire Fighting › Fixed Fire Detection System › Smoke Detectors
Issued 25 March 2009 Resolved
Provide smoke detector on main deck between galley and berthing area.
Action required: 705 - Other - as specified
Due 25 April 2009
Resolved 25 March 2009
Documentation › Certificates/Documents › Certificate of Inspection
Issued 23 February 2006 Resolved
Vessel has exceeded its drydock exam interval. Vessel has been granted a 30 day drydock extension. Vessel must be made available for inspection before 25 Mar 06.
Action required: 705 - Other - as specified
Due 25 March 2006
Resolved 7 April 2006
Resolution: Dry dock completed.
Lifesaving › Launching Appliances
Issued 28 May 2004 Resolved
The M/V [name withheld] shall not operate until an approved rescue boat davit is installed as per 46 CFR 133.160. LEGACY COMPONENT DESC: Davit
Action required: 17 - Rectify deficiencies prior to departure
Resolved 10 June 2004
Resolution: issued new 835
Lifesaving › Launching Appliances › Davit
Issued 28 May 2004 Resolved
INSTALL RESCUE BOAT DAVIT AS PER 46 CFR 133.160. VESSEL MAY OPERATE USING THE INSTALLED DECK CRANE, MODEL # CTB-25-2-70, AS THE RESCUE BOAT LAUNCHING DEVICE UNTIL AN APPROVED RESCUE BOAT DAVIT IS INSTALLED. RESCUE BOAT MUST BE ABLE TO BE LAUNCHED WITHIN 5 MINUTES OF REPORT OF MOB. LEGACY COMPONENT DESC: Davit
Action required: 705 - Other - as specified
Due 10 July 2004
Resolved 19 July 2004
Engineering › Diesel Engine (propulsion-reduction gear)
Issued 10 June 2003 Resolved
CONDUCT OVERSPEED TEST TO BOTH MAIN DIESEL ENGINES IN THE PRESENCE OF A CG MARINE INSPECTOR.
Due 10 July 2003
Resolved 11 June 2003
Resolution: OBSERVED OPERATIONAL TEST
Lifesaving › Launching Appliances
Issued 10 June 2003 Resolved
SUBMIT REQUEST TO COMMANDANT G-MSE FOR AN EQUIVALENT FOR RESCUE BOAT DAVIT. LEGACY COMPONENT DESC: Davit
Due 25 August 2003
Resolved 16 June 2004
Resolution: Cleared this requirement and issued another requirement to replace davit with approved davit.
Navigation › Piloting/Steering
Issued 10 June 2003 Resolved
PROVIDE TABLE PRIOR TO DEPARTURE FROM PORT LEGACY COMPONENT DESC: Compass Deviation Table
Action required: 17 - Rectify deficiencies prior to departure
Due 11 June 2003
Resolved 12 June 2003
Resolution: Received copy of deviation table.
Operations/Management › Equipment Service/Testing › EPIRB
Issued 10 June 2003 Resolved
SUBMIT AUTOMATION TEST PROCEDURES TO OCMI FOR APPROVAL. RETURNED FIRST SUBMISSION FOR REVISION.
Due 25 August 2003
Resolved 26 May 2005
Lifesaving › Rescue Boat
Issued 10 June 2003 Resolved
PROVIDE RETRO REFLECTIVE MATERIAL PER 46CFR 131.855
Due 18 June 2003
Resolved 11 June 2003
Resolution: OBSERVED MARKINGS
Engineering › Fuel Oil Storage/Transfer System
Issued 10 June 2003 Resolved
PROVE PROPER OPERATION OF EMERGENCY SHUTDOWN OF PRIMARY AND SECONDARY FUEL TRANSFER PUMPS. LEGACY COMPONENT DESC: Pump
Action required: 705 - Other - as specified
Due 18 June 2003
Resolved 11 June 2003
Resolution: OBSERVED PROPER OPERATION.
Lifesaving › Launching Appliances
Issued 10 June 2003 Resolved
PROVIDE RESULTS OF WEIGHT TEST. LEGACY COMPONENT DESC: Davit
Action required: 17 - Rectify deficiencies prior to departure
Due 11 June 2003
Resolved 12 June 2003
Resolution: Received loat test results conducted by southern crane & hydraulic. test sat.
Lifesaving › Inflatable Liferafts
Issued 30 May 2002 Resolved
Provide an additional liferaft on the port side to bring the total capacity available on each side to at least 100 percent of the total number of persons on board.
Due 30 June 2002
Resolved 7 June 2002
Lifesaving › Inflatable Liferafts
Issued 29 May 2002 Resolved
Service outdated loferafts.
Due 30 June 2002
Resolved 7 June 2002
Lifesaving
Issued 29 May 2002 Resolved
Provide water light for required number of reing buoys.
Due 30 June 2002
Resolved 7 June 2002
Engineering › Diesel Engine (propulsion-reduction gear)
Issued 29 May 2002 Resolved
Prove all alarms and shutdown on main diesel engines and ship service generators and proper operation.
Due 30 June 2002
Resolved 7 June 2002
Engineering › Steering Gear System
Issued 29 May 2002 Resolved
Prove steering gear.
Due 30 June 2002
Resolved 7 June 2002
Fire Fighting › Fire Hydrants
Issued 29 May 2002 Resolved
Make all fire station, hoses and nozzle compatible. LEGACY COMPONENT DESC: Condition
Due 30 June 2002
Resolved 7 June 2002
Fire Fighting › Portable Dry Chemical Fire Extinguisher
Issued 29 May 2002 Resolved
Provide and install the proper number and type fire extinguishers on board the vessel. LEGACY COMPONENT DESC: Condition
Due 30 June 2002
Resolved 7 June 2002
Engineering › Diesel Engine (propulsion-reduction gear)
Issued 29 May 2002 Resolved
Provide and install lagging around turbo charger and exhaust on both main engines.
Due 30 June 2002
Resolved 7 June 2002
Engineering › Diesel Engine (auxiliary)
Issued 29 May 2002 Resolved
Repair fuel leaks on the starboard ship service generator.
Due 30 June 2002
Resolved 7 June 2002
Stability › Watertight Integrity
Issued 29 May 2002 Resolved
Provide and install gaskets for both water tight doors in engine room leading to main deck. LEGACY COMPONENT DESC: WTD''''s
Due 30 June 2002
Resolved 7 June 2002
Personnel › Training
Issued 29 May 2002 Resolved
Complete abandon ship, man overboard and fire drills. LEGACY COMPONENT DESC: Familiarization Training
Due 30 June 2002
Resolved 7 June 2002
Electrical › Lighting (emergency)
Issued 29 May 2002 Resolved
Prove emergency lighting.
Due 30 June 2002
Resolved 7 June 2002
Documentation › Logs/Records
Issued 29 May 2002 Resolved
Provide life saving equipment maintenance record. LEGACY COMPONENT DESC: Logbook/Record (unofficial)
Due 30 June 2002
Resolved 7 June 2002
Stability › Watertight Integrity
Issued 29 May 2002 Resolved
Replace broken port light cover dog in the captains state room and replace gasket in port light covers in crewsd state rooms. LEGACY COMPONENT DESC: Port light covers and dogs.
Due 30 June 2002
Resolved 7 June 2002
Construction/Loadline › Hull
Issued 9 April 2002 Resolved
Provide NDT inspection report of port anchor pocket to Coast Guard prior to getting u/w.
Condition: Damaged By Earlier Event
Due 10 April 2002
Resolved 10 April 2002
Engineering
Issued 5 August 1999 Resolved
DEMONSTRATE PROPER OPERATION OF ENGINEERING AND FIRE DETECTION AUTOMATION SYSTEMS TO THE SATISFACTION OF THE ATTENDING MARINE INSPECTOR.
Condition: Unknown
Due 5 August 1999
Resolved 5 August 1999
Electrical
Issued 5 August 1999 Resolved
DEMONSTRATE PROPER OPERATION OF BOTH GENERATOR OVERSPEEDS AND REVERSE POWERRELAYS.
Condition: Unknown
Due 5 August 1999
Resolved 5 August 1999
Lifesaving
Issued 27 July 1996 Resolved
VSL IS IN COMPLETE DISREPAIR. MAIN DECK AND ALL SPACES ARE IN COMPLETE DISORDER PRESENTING MANY ELECTRICAL AND FIRE HAZARDS TO THE CREW AND VSL.
Condition: Unknown
Due 14 December 1998
Resolved 14 December 1998
Engineering
Issued 27 July 1996 Resolved
[withheld — contains personal information; the deficiency system, dates, and resolution status are shown above]
Condition: Unknown
Due 30 July 1996
Resolved 22 January 1997
Documentation
Issued 27 July 1996 Resolved
COMPLY WITH CHEMICAL TESTING REQUIREMENTS IN 46 CFR 16._x001C_ _x001C_ _x001C_ _x001C_
Condition: Unknown
Due 14 December 1998
Resolved 14 December 1998
Documentation
Issued 27 July 1996 Resolved
UPDATE VSL CERTIFICATE OF DOCUMENTATION._x001C_ _x001C_ _x001C_ _x001C_
Condition: Unknown
Due 14 December 1998
Resolved 14 December 1998
Navigation
Issued 27 July 1996 Resolved
PROVIDE A COPY OF INLAND NAV RULES
Condition: Unknown
Due 14 December 1998
Resolved 14 December 1998
Navigation
Issued 27 July 1996 Resolved
PROVIDE CHARTS FOR OPERATING AREAS._x001C_ _x001C_ _x001C_ _x001C_
Condition: Unknown
Due 14 December 1998
Resolved 14 December 1998
Documentation
Issued 27 July 1996 Resolved
PROVIDE VALID RADIO STATION LICENSE_x001C_ _x001C_ _x001C_ _x001C_
Condition: Unknown
Due 14 December 1998
Resolved 14 December 1998
Construction/Loadline
Issued 27 July 1996 Resolved
HULL SEVERLY WASTED IN MANY AREAS--INTERNAL BALLAST TANKS WASTED THRU DRAINING WATER INTO E/R; MAIN DECK HATCH COVERS WASTED THRU; STRUCTURAL DAMGE ON PORT BOW AS A RESULT OF COLLISION WITH DOCK IN HAITI; & STDB MAIN DECK ACCESS TO E/R HOLED/WASTED THRU COMPROMISING WEATHER TIGHT INTEGRITY.
Condition: Unknown
Due 14 December 1998
Resolved 14 December 1998
Electrical
Issued 27 July 1996 Resolved
REPAIR ALL ELECTRICAL WIRING/CONNECTIONS IAW GOOD MARINE PRACTICE TO PREVENT TO REDUCE THE RISK OF FIRE AS A RESULT OF POOR ELECTRICAL SYSTEM MANTENANCE._x001C_ _x001C_
Condition: Unknown
Due 14 December 1998
Resolved 14 December 1998
Construction/Loadline
Issued 27 July 1996 Resolved
PUMP BILGES TO REMOVE ACCUMULAITON OF WASTE OIL IN THE BILGES, WHICH PRESENTS A FIRE HAZARD._x001C_ _x001C_ _x001C_
Condition: Unknown
Due 30 July 1996
Resolved 22 January 1997
Engineering
Issued 27 July 1996 Resolved
PROVIDE CONTAINMENT AROUND FUEL OIL TRANSFER STATION._x001C_ _x001C_ _x001C_ _x001C_
Condition: Unknown
Due 14 December 1998
Resolved 14 December 1998
Fire Fighting
Issued 27 July 1996 Resolved
PROVIDE REQUIRED NUMBER OF SERVICED/UPDATED FIRE EXTINGUISHERS._x001C_ _x001C_ _x001C_ _x001C_
Condition: Unknown
Due 30 July 1996
Resolved 22 January 1997
Engineering
Issued 27 July 1996 Resolved
PROVIDE FUEL OIL TRANSFER PROCEDURES._x001C_ _x001C_ _x001C_ _x001C_
Condition: Unknown
Due 14 December 1998
Resolved 14 December 1998
Navigation
Issued 27 July 1996 Resolved
PROVIDE REQUIRED NAVIGATION LIGHTS PRIOR TO GETTING UNDERWAY._x001C_ _x001C_ _x001C_ _x001C_
Condition: Unknown
Due 14 December 1998
Resolved 14 December 1998
Documentation
Issued 27 July 1996 Resolved
[withheld — contains personal information; the deficiency system, dates, and resolution status are shown above]
Condition: Unknown
Due 14 December 1998
Resolved 14 December 1998
Lifesaving
Issued 27 July 1996 Resolved
PROVIDE REQUIRED #/TYPE OF PFDs FOR CREW._x001C_ _x001C_ _x001C_ _x001C_
Condition: Unknown
Due 14 December 1998
Resolved 14 December 1998
Lifesaving
Issued 27 July 1996 Resolved
PROVIDE REQUIRED #/TYPE OF WORKVESTs FOR CREW._x001C_ _x001C_ _x001C_ _x001C_
Condition: Unknown
Due 14 December 1998
Resolved 14 December 1998
Lifesaving
Issued 27 July 1996 Resolved
APPLY VSL NAME AND RETRO TAPE ON ALL LIFESAVING EQUIPMENT._x001C_ _x001C_ _x001C_ _x001C_
Condition: Unknown
Due 14 December 1998
Resolved 14 December 1998

Casualty record · 5

6 July 2002Significant Marine Casualty · role: Involved in a Marine Casualty · serious marine incident, as classified · 1 dead · activity 1645241
12 October 2005Routine · role: Involved in a Marine Casualty · activity 2513033
2 September 2012Routine · role: Involved in a Marine Casualty · activity 4461334
30 October 2023Routine · role: Involved in a Marine Casualty · activity 7820801
26 April 2025Routine · role: Involved in a Marine Casualty · activity 8128813
Each line is an incident investigation the Coast Guard recorded with this hull among the vessels involved, with the date and the classification the Coast Guard gave it, and the bridge, lock or dam the investigation names where it names one. Involvement is not fault. The investigation narrative is not published. Source: IIR, through 2026.

Recorded names · 2

MR. FRED (2002–2005), MR FRED (2012). Names as the Coast Guard recorded them in incident records, with the years they appear; some are renames and some are spelling variants.

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.