Records from 1984 to 1990. Most recent: inspection, 25 November 1990.
A report is not offered for this hull: Its record holds only 2 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. Reports.
Inspection history · 17
25 November 1990
Type not recorded
No type recorded · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 909864
7 November 1990
Administrative
Administrative · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1219648
24 March 1989
Type not recorded
No type recorded · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1040678
21 November 1988
Administrative
Administrative · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 893391
24 September 1988
COI Inspection
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 891120
11 February 1988
Administrative
Administrative · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1030154
30 September 1987
Re-Inspection
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1326514
30 July 1987
Administrative
Administrative · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1334662
12 July 1987
Hull Examination
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1331920
14 April 1987
Drydock Extension
Administrative · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1017058
25 March 1987
Administrative
Administrative · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1325882
30 December 1986
Deficiency Check
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1309642
19 September 1986
COI Inspection
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1321033
27 February 1986
Type not recorded
No type recorded · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1298641
22 September 1985
Re-Inspection
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 988841
27 April 1985
Credit Drydock
Administrative · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 991330
18 December 1984
Type not recorded
No type recorded · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 977537
Lifesaving
Issued 24 September 1988
Resolved
REPLACE OUTDATED ROCKETS AND PRIMERS FOR LINE THROWING APPLIANCE.
Condition: Unknown
Due 24 September 1988
Resolved 24 September 1988
Lifesaving
Issued 24 September 1988
Resolved
REPLACE ALL DOOR GASKETS AND COXSWAINS WINDOW IN LIFEBOAT NO.2.
Condition: Unknown
Due 24 September 1988
Resolved 24 September 1988
Fire Fighting
Issued 24 September 1988
Resolved
HYDRO OUTDATED SCBA BOTTLE.
Condition: Unknown
Due 24 September 1988
Resolved 24 September 1988
Fire Fighting
Issued 24 September 1988
Resolved
SUBMIT REVISED FIRE PLAN THAT INDICATES ACTUAL LOCATIONS AND NUMBERS OF FIRE DAMPERS AND ALL INSTALLED ALARM BELLS AND INDICATORS.
Condition: Unknown
Due 4 December 1988
Resolved 18 May 2002
Resolution: MISLE Maintenance - Resolved all open deficiencies issued prior to 6/1/1997 where activity was closed and deficiency due date was past
Electrical
Issued 24 September 1988
Resolved
REPLACE LOW VOLTAGE BATTERIES FOR CO2 SYSTEM ALARMS.
Condition: Unknown
Due 24 September 1988
Resolved 24 September 1988
Lifesaving
Issued 24 September 1988
Resolved
[withheld — contains personal information; the deficiency system, dates, and resolution status are shown above]
Condition: Unknown
Due 24 September 1988
Resolved 24 September 1988
Deck/Cargo
Issued 24 September 1988
Resolved
CONDUCT AND PROVIDE TEST CERTIFICATES FOR PORT AND STARBOARD CRANE QUADRENNIAL PROOF LOAD TEST.
Condition: Unknown
Due 24 September 1988
Resolved 24 September 1988
Electrical
Issued 24 September 1988
Resolved
INSTALL CLASS 1 DIVISION 2 TYPE GENERAL ALARM BELL IN MUD PIT ROOM AND REMOVE NON-CLOSED ROTATING BEACON FROM SPACE.
Condition: Unknown
Due 24 September 1988
Resolved 24 September 1988
Fire Fighting
Issued 24 September 1988
Resolved
HYDROSTATICALLY TEST OR REPLACE ALL OUT OF DATE PORTABLE CO2 FIRE EXTINGUISHERS AND DRY CHEMICAL PROPELLENT CHARGES.
Condition: Unknown
Due 24 September 1988
Resolved 24 September 1988
Electrical
Issued 24 September 1988
Resolved
REPLACE 24 VOLT BATTERY CHARGER TO EMERGENCY GENERATOR STARTING BATTERIES WITH A 36 VOLT CHARGER.
Condition: Unknown
Due 24 September 1988
Resolved 24 September 1988
Lifesaving
Issued 24 September 1988
Resolved
HAVE SERVICED AND REINSTALL LIFERAFTS AND HYDROSTATIC RELEASES FOR SAME.
Condition: Unknown
Due 24 September 1988
Resolved 24 September 1988
Lifesaving
Issued 24 September 1988
Resolved
REPLACE ALL THROW OVER LIFERAFTS W/DAVIT LAUNCHED LIFERAFTS.
Condition: Unknown
Due 4 April 1989
Resolved 18 May 2002
Resolution: MISLE Maintenance - Resolved all open deficiencies issued prior to 6/1/1997 where activity was closed and deficiency due date was past
Documentation
Issued 12 July 1987
Resolved
MAKE AVAILABLE AND POST A HAZARDOUS LOCATION PLAN. THE PLAN MUST IDENTIFY THE AREAS AS PER 46 CFR 108.171.
Condition: Unknown
Due 12 July 1987
Resolved 12 July 1987
Construction/Loadline
Issued 27 April 1985
Resolved
COMPLETE PERMANENT REPAIRS AND HOSE TEST MAIN DECK PLATE INSERT OVER ENGINEROOM.
Condition: Unknown
Due 27 April 1985
Resolved 27 April 1985
Fire Fighting
Issued 27 April 1985
Resolved
RELOCATE BOTH HELODECK FIRE STATIONS AWAY FROM THE IMMEDIATE PROXIMITY OF THE LANDING CIRCLE.
Condition: Unknown
Due 27 April 1985
Resolved 27 April 1985
Construction/Loadline
Issued 27 April 1985
Resolved
PROVIDE FLAME SCREENS ON ALL VENTS SERVING VOID NO. 4 STBD UNTIL CLEANED OFALL FUEL OIL AND FUMES.
Condition: Unknown
Due 27 April 1985
Resolved 27 April 1985
Construction/Loadline
Issued 27 April 1985
Resolved
MAKE SAFE FOR INTERNAL EXAMINATION VOID NO. 4 STBD TO DETECT AND REPAIR AS NECESSARY THE SOURCE OF FUEL OIL LEAK.
Condition: Unknown
Due 27 April 1985
Resolved 27 April 1985
Construction/Loadline
Issued 27 April 1985
Resolved
PROVIDE ABS APPROVED DRAWING OF ACTUAL MODIFICATION OF SPUD CAN BRACEWORK, WHICH WAS NOT ACCOMPLISHED ACCORDING TO APPROVED DRAWINGS.
Condition: Unknown
Due 27 April 1985
Resolved 27 April 1985