LLOYD NOBLE is a 1983 mobile offshore drilling unit. The Coast Guard has recorded 52 inspections since 1983, most recently in March 1996, along with 62 deficiencies.

Records from 1983 to 1996. Most recent: inspection, 11 March 1996.

Built
1983
Last inspected
11 March 1996
Documentation
Not in the documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

Flag
UNITED STATES
—
Maury page id
psix-54773

Inspections, by type

…with no type recorded20
Years with a record 14 calendar years (1983–1996)
The 52 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

This record may be incomplete: the most recent inspection recorded for this vessel was 30 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Offshore class in Maury's sources begin in 1978.

Documentation record

Tonnage as PSIX records it4783 - Regulatory (Subpart C or D), Gross Ton
4783 - Regulatory (Subpart C or D), Net Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.

Radio station licence

KZQEMMSI not assigned · expired · voluntarily equipped · granted 14 November 1991, cancelled 14 November 1996 · licensed under a name not among this hull’s recorded names (not shown)
FCC Universal Licensing System ship-station file of 6 September 2026, matched to this hull on its US Official Number. Status and dates are the file’s own. The licensee is not read from the file and is not shown. A lapsed licence’s MMSI is still the number the vessel transmitted under while it was valid.

A report is not offered for this hull: Its record holds only 2 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. Reports.

Inspection history · 52

11 March 1996 Administrative
Administrative · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1077492
19 December 1995 Administrative
Administrative · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 884128
24 July 1995 Deficiency Check
Physical examination · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 1428508
12 July 1995 Administrative
Administrative · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1079253
28 June 1995 Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 881663
17 May 1995 Re-Inspection
Physical examination · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1357165
20 December 1994 Administrative
Administrative · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 844268
6 December 1994 Administrative
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1139389
2 December 1994 Administrative
Administrative · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 869803
30 September 1994 Deficiency Check
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 870943
14 June 1994 Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 676942
23 May 1994 Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 75297
8 April 1994 COI Inspection
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1410946
6 December 1993 Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 849596
1 November 1993 Deficiency Check
Physical examination · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 836543
20 September 1993 Administrative
Administrative · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 844128
7 September 1993 Hull Examination
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 852211
7 September 1993 Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1460655
23 April 1993 Re-Inspection
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1136925
23 October 1992 Type not recorded
No type recorded · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 945932
1 April 1992 COI Inspection
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 942953
22 February 1992 Administrative
Administrative · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1318678
10 February 1992 Administrative
Administrative · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1254879
18 November 1991 Deficiency Check
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 943541
12 September 1991 Hull Examination
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 942270
23 August 1991 Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1258841
9 July 1991 Deficiency Check
Physical examination · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1253673
20 May 1991 Re-Inspection
Physical examination · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 1231930
10 May 1991 Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1215871
14 August 1990 Hull Examination
Physical examination · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 911129
15 May 1990 COI Inspection
Physical examination · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 1241031
6 March 1990 Type not recorded
No type recorded · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 924677
6 March 1990 Type not recorded
No type recorded · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 925477
25 January 1990 Re-Inspection
Physical examination · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 920030
1 May 1989 Administrative
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1343341
23 January 1989 COI Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1209825
30 June 1988 Administrative
Administrative · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1340497
17 May 1988 Administrative
Administrative · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1349798
1 April 1988 Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 993913
1 March 1988 Re-Inspection
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1029438
9 February 1988 Hull Examination
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1020612
21 July 1987 Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1337032
16 January 1987 Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1007152
13 January 1987 COI Inspection
Physical examination · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1313583
26 March 1986 Re-Inspection
Physical examination · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1309484
30 July 1985 Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1290564
20 May 1985 Type not recorded
No type recorded · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 982869
19 March 1985 Type not recorded
No type recorded · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 982478
23 January 1985 Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 979364
9 February 1984 Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 971124
26 January 1984 Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1279102
29 January 1983 Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 966604

Deficiency record · 62

Accommodation/Occupational Safety
Issued 17 May 1995 Resolved
REPAIR/REPLACE AUTOMATIC DOOR CLOSURE IN STAIR TOWER.
Condition: Unknown
Due 17 May 1995
Resolved 17 May 1995
Electrical
Issued 17 May 1995 Resolved
REPAIR EMERGENCY SHUT-DOWN HANDLE TO EMERGENCY GENERATOR.
Condition: Unknown
Due 17 July 1995
Resolved 28 June 1995
Electrical
Issued 17 May 1995 Resolved
REMOVE/REPAIR 3M TEMPORARY SPLICE WIRE IN MUDPUMP ROOM STARBOARD SIDE.
Condition: Unknown
Due 17 June 1995
Resolved 28 June 1995
Fire Fighting
Issued 17 May 1995 Resolved
REPLACE DISCHARGE LINE FROM HALON BOTTLE NO.4 IN SACK ROOM.
Condition: Unknown
Due 17 May 1995
Resolved 17 May 1995
Accommodation/Occupational Safety
Issued 17 May 1995 Resolved
REPAIR/RENEW SALT WATER DISCHARGE LINE AND VALVE FROM AIR COMPRESSOR NO.2.
Condition: Unknown
Due 17 July 1995
Resolved 28 June 1995
Electrical
Issued 17 May 1995 Resolved
REPAIR EMERGENCY FUEL SHUT-OFF VALVE TO EMERGENCY GENERATOR.
Condition: Unknown
Due 17 July 1995
Resolved 28 June 1995
Fire Fighting
Issued 17 May 1995 Resolved
CROP AND RENEW FIRE MAIN PIPE (CEMENT PUMP ROOM) FROM NO.2 FIRE PUMP.
Condition: Unknown
Due 17 May 1995
Resolved 17 May 1995
Fire Fighting
Issued 17 May 1995 Resolved
CROP AND RENEW FIRE MAIN PIPE (B.J. ROOM) BY EMERGENCY LIGHT OVERHEAD.
Condition: Unknown
Due 17 May 1995
Resolved 17 May 1995
Documentation
Issued 17 May 1995 Resolved
PROVIDE ONBOARD THE APPROVED FIRE CONTROL AND HAZARDOUS LOCATION PLANS.
Condition: Unknown
Due 17 May 1995
Resolved 17 May 1995
Fire Fighting
Issued 17 May 1995 Resolved
CROP AND RENEW FIRE MAIN PIPE (OVER HEAD) ON NO.1 FIRE PUMP.
Condition: Unknown
Due 17 May 1995
Resolved 17 May 1995
Accommodation/Occupational Safety
Issued 17 May 1995 Resolved
CROP AND RENEW SALT WATER MAIN PIPING (APPROX. 18" IN DIA.) IN AIR COMPRESSOR.
Condition: Unknown
Due 17 May 1995
Resolved 17 May 1995
Electrical
Issued 30 September 1994 Resolved
CHANGE DIRECTION OF SWING ON BOTH MUD PIT ROOM DOORS TO COMPLY WITH 46 CFR 111.105-33(F)(3)(i).
Condition: Unknown
Due 18 October 1994
Resolved 18 October 1994
Deck/Cargo
Issued 8 April 1994 Resolved
PROVIDE UL/FM LABEL FOR RIG FORKLIFT.
Condition: Unknown
Due 8 April 1994
Resolved 8 April 1994
Deck/Cargo
Issued 8 April 1994 Resolved
PROVIDE OIL TRANSFER PROCEDURES AND HYDRO DATE FOR OIL TRANSFER HOSE.
Condition: Unknown
Due 8 April 1994
Resolved 8 April 1994
Fire Fighting
Issued 8 April 1994 Resolved
HYDRO-TEST HALON AND N2 CYLINDERS FOR ENGINE ROOM.
Condition: Unknown
Due 8 April 1994
Resolved 8 April 1994
Electrical
Issued 8 April 1994 Resolved
PROVE PROPER OPERATION OF MUD PIT ROOM VENTILATION REMOTE SHUTDOWN.
Condition: Unknown
Due 8 April 1994
Resolved 8 April 1994
Lifesaving
Issued 8 April 1994 Resolved
RENEW AND PROVE PROPER OPERATION OF BOTH MUD PIT ROOM DOORS
Condition: Unknown
Due 8 April 1994
Resolved 8 April 1994
Unknown
Issued 7 September 1993 Resolved
REDUCE ALLOWED MANNING TO 58 PERSONS TOTAL UNTIL DAMAGED 58 PERSON SURVIVALCAPSULE IS REPAIRED AND RETURNED TO MODU.
Condition: Unknown
Due 15 November 1993
Resolved 1 November 1993
Construction/Loadline
Issued 7 September 1993 Resolved
IN ORDER TO RECEIVE FULL DRYDOCK CREDIT, UNIT MUST COMPLETE INTERNAL STRUCTURAL AND EXTERIOR HULL EXAM.
Condition: Unknown
Due 7 September 1993
Resolved 7 September 1993
Lifesaving
Issued 7 September 1993 Resolved
MAKE PERMANENT REPAIRS TO HULL OF DAMAGED 58 PERSON SURVIVAL CAPSULE.
Condition: Unknown
Due 15 November 1993
Resolved 1 November 1993
Lifesaving
Issued 12 September 1991 Resolved
REINSTALL AND PROVE OPERATION OF QUICK-RELEASE DEVICES FOR RING BUOYS._x001C_
Condition: Unknown
Due 12 September 1991
Resolved 12 September 1991
Lifesaving
Issued 12 September 1991 Resolved
REINSTALL PORT FORWARD, STBD FORWARD AND STARBOARD AFT LIFEBOAT DAVITS. FOLLOWING INSTALLATION, CONDUCT SATISFACTORY WEIGHT TEST OF DAVITS TO SATISFACTION OF A COAST GUARD MARINE INSPECTOR._x001C_
Condition: Unknown
Due 12 September 1991
Resolved 12 September 1991
Unknown
Issued 20 May 1991 Resolved
PROVE PROPER OPERATION OF DRILL FLOOR AIR RECEIVER RELIEF VALVE.
Condition: Unknown
Due 20 May 1991
Resolved 20 May 1991
Fire Fighting
Issued 20 May 1991 Resolved
PROVE PROPER OPERATION OF FIXED FIRE EXTINGUISHING SYSTEMS
Condition: Unknown
Due 20 May 1991
Resolved 20 May 1991
Construction/Loadline
Issued 14 August 1990 Resolved
CLEAN AND PRESENT FOR INSPECTION THE SPUD CAN HIGH STRESS CONNECTIONS.
Condition: Unknown
Due 14 August 1990
Resolved 14 August 1990
Engineering
Issued 25 January 1990 Resolved
RENEW ENGINEROOM VENTILATION REMOTE SHUTDOWN EMERGENCY SWITCHES LOCATED ON RIG'S AMIDSHIP AREA AND THOSE LOCATED ON THE DRILL FLOOR.
Condition: Unknown
Due 25 January 1990
Resolved 25 January 1990
Electrical
Issued 25 January 1990 Resolved
RENEW THE EMERGENCY GENERATOR HIGH TEMPERATURE ALARM SENDING UNIT.
Condition: Unknown
Due 25 January 1990
Resolved 25 January 1990
Lifesaving
Issued 25 January 1990 Resolved
EXERCISE THE PORT AND STARBOARD LIFEBOATS IN THE WATER.
Condition: Unknown
Due 25 January 1990
Resolved 25 January 1990
Electrical
Issued 25 January 1990 Resolved
EFFECT REPAIRS AND SATISFACTORY TEST THE LOST OF AIR PURGE ALARM ON THE DRILLERS CONSOLE.
Condition: Unknown
Due 25 January 1990
Resolved 25 January 1990
Electrical
Issued 25 January 1990 Resolved
CLEAN AND SATISFACTORY TEST THE HAZARDOUS GAS SENSOR PROBES LOCATED IN THE SHALE SHAKER AND MUD PIT ROOMS.
Condition: Unknown
Due 25 January 1990
Resolved 25 January 1990
Engineering
Issued 25 January 1990 Resolved
RENEW GENERATOR PRIME MOVERS REMOTE SHUTDOWN EMERGENCY SWITCHES LOCATED ON RIG'S AMIDSHIP AREA AND THOSE LOCATED ON THE DRILL FLOOR.
Condition: Unknown
Due 25 January 1990
Resolved 25 January 1990
Construction/Loadline
Issued 23 January 1989 Resolved
ADJUST AS NECESSARY THE QUICK ACTING WATERTIGHT DOORS BELOW THE MAIN DECK TO SEAL PROPERLY. CHALK TEST TO ENSURE EQUAL PRESSURE ON THE KNIFE EDGE. (SOME HINGE PINS MAY NEED TO BE REPLACED)
Condition: Unknown
Due 23 January 1989
Resolved 23 January 1989
Deck/Cargo
Issued 23 January 1989 Resolved
REPLACE THE RELIEF VALVE ON THE DRILL FLOOR AIR RECEIVER. SET PRESSURE AT 150 PSI.
Condition: Unknown
Due 23 January 1989
Resolved 23 January 1989
Lifesaving
Issued 23 January 1989 Resolved
MAKE OPERABLE QUARTERS VENTILATION SHUTDOWN ON SECOND AND THIRD DECK. (SHUNT ON ORDER)
Condition: Unknown
Due 23 January 1989
Resolved 23 January 1989
Lifesaving
Issued 23 January 1989 Resolved
ADD GENERAL ALARM BELL IN MUD PIT.
Condition: Unknown
Due 23 January 1989
Resolved 23 January 1989
Lifesaving
Issued 23 January 1989 Resolved
ADD GENERAL ALARM BELL AT PORTSIDE MAIN DECK. NO OTHERS COULD BE HEARD ON THE MAIN DECK FROM THAT AREA.
Condition: Unknown
Due 23 January 1989
Resolved 23 January 1989
Deck/Cargo
Issued 23 January 1989 Resolved
PROVIDE AN ASME APPROVED RELIEF VALVE FOR THE BULK SYSTEM DOWN LINE FROM THE REGULATOR.
Condition: Unknown
Due 23 January 1989
Resolved 23 January 1989
Engineering
Issued 23 January 1989 Resolved
CORRECT THE BAD BEARING IN THE #1 BILGE PUMP.
Condition: Unknown
Due 23 January 1989
Resolved 23 January 1989
Fire Fighting
Issued 23 January 1989 Resolved
PROVIDE EITHER FIREMANS PANTS FOR THE WASTE COATS ON BOARD OR PROVIDE 3/4 LENGTH COATS FOR THE FIREMAN'S OUTFITS.
Condition: Unknown
Due 23 January 1989
Resolved 23 January 1989
Deck/Cargo
Issued 23 January 1989 Resolved
TEST THE RIG SHUTDOWN IN THE PRESENCE OF A COAST GUARD INSPECTOR.
Condition: Unknown
Due 23 January 1989
Resolved 23 January 1989
Electrical
Issued 23 January 1989 Resolved
FILL ALL EYES FITTINGS WITH CORRECT SEALANT MATERIAL.
Condition: Unknown
Due 23 January 1989
Resolved 23 January 1989
Electrical
Issued 23 January 1989 Resolved
REPLACE WASTED EMBARKATION LIGHT BY STBD LIFEBOAT.
Condition: Unknown
Due 23 January 1989
Resolved 23 January 1989
Electrical
Issued 23 January 1989 Resolved
PRIOR TO DRILLING MAKE AN OPERABLE ALL GAS DETECTORS ON DRILL FLOOR, SHALE SHAKER AREA AND MUD PITS.
Condition: Unknown
Due 23 January 1989
Resolved 23 January 1989
Electrical
Issued 1 March 1988 Resolved
PROVE SATISFACTORY OPERATION OF THE PURGING SYSTEM TO THE DRILLER'S CONSOLEON THE DRILL FLOOR, VISUAL AND AUDIBLE ALARM.
Condition: Unknown
Due 1 March 1988
Resolved 1 March 1988
Accommodation/Occupational Safety
Issued 13 January 1987 Resolved
TEST IN THE PRESENCE OF A MARINE INSPECTOR, THE THREE AIR RECEIVER RELIEF VALVES.
Condition: Unknown
Due 13 January 1987
Resolved 13 January 1987
Electrical
Issued 13 January 1987 Resolved
REPAIR AND TEST IN THE PRESENCE OF A MARINE INSPECTOR ALL THREE MAIN GENERATOR LUBE OIL SHUTDOWN ALARMS.
Condition: Unknown
Due 13 January 1987
Resolved 13 January 1987
Electrical
Issued 13 January 1987 Resolved
REPAIR AND TEST THE AUTOMATIC BUS TRANSFER ON THE EMERGENCY GENERATOR.
Condition: Unknown
Due 13 January 1987
Resolved 13 January 1987
Construction/Loadline
Issued 30 July 1985 Resolved
MAKE EFFECTIVE REPAIRS TO THE TRANSVERSE CRACK AT THE TOP OF THE BOTTOM VERTICLE WELD SIDE "A" CHORD BOW LEG.
Condition: Unknown
Due 30 July 1985
Resolved 30 July 1985
Construction/Loadline
Issued 30 July 1985 Resolved
MAKE EFFECTIVE REPAIRS TO THE DIAGONAL CRACK AT THE TOP OF THE BOTTOM VERTICLE WELD SIDE "B" CHORD BOW LEG.
Condition: Unknown
Due 30 July 1985
Resolved 30 July 1985
Construction/Loadline
Issued 30 July 1985 Resolved
MAKE EFFECTIVE REPAIRS TO THE TRANSVERSE CRACK AT THE TOP OF THE BOTTOM VERTICLE WELD SIDE "A" CHORD PORT LEG.
Condition: Unknown
Due 30 July 1985
Resolved 30 July 1985
Construction/Loadline
Issued 30 July 1985 Resolved
SUBMIT A PROPOSAL OF REPAIR TO THE TRANSVERSE CRACK ON LOWER EDGE OF BOTTOMVERTICLE WELD SIDE "A" CHORD BOW LEG.
Condition: Unknown
Due 30 July 1985
Resolved 30 July 1985
Construction/Loadline
Issued 30 July 1985 Resolved
MAKE EFFECTIVE REPAIRS TO THE TRANSVERSE CRACK ON LOWER EDGE OF BOTTOM VERTICLE WELD SIDE "A" CHORD BOW LEG.
Condition: Unknown
Due 30 July 1985
Resolved 30 July 1985
Electrical
Issued 23 January 1985 Resolved
PROVIDE NON HEAT SENSITIVE FUEL OIL DAY TANK SUPPLY VALVES 46 CFR 56.50-60
Condition: Unknown
Due 23 January 1985
Resolved 23 January 1985
Deck/Cargo
Issued 23 January 1985 Resolved
PROVIDE A HAND LIFTING DEVICE FOR THE P TANKS RELIEF VALVES 46 CFR 54.15-10.
Condition: Unknown
Due 23 January 1985
Resolved 23 January 1985
Fire Fighting
Issued 23 January 1985 Resolved
PROVIDE GENERAL ALARMS SUITABLE FOR HAZARDOUS LOCATIONS APPROVED BY A TEST-ING LABORATORY. 46 CFR 111.10.
Condition: Unknown
Due 23 January 1985
Resolved 23 January 1985
Accommodation/Occupational Safety
Issued 23 January 1985 Resolved
PROVIDE REMOTE VENTILATION SHUTDOWN SWITCHES FOR HAZARDOUS LOCATION ON THE DRILL FLOOR APPROVED BY A TESTING LABORATORY 46 CFR 111.105.
Condition: Unknown
Due 23 January 1985
Resolved 23 January 1985
Unknown
Issued 23 January 1985 Resolved
THE FOLLOWING DEFICIENCIES PERTAIN TO THE VESSEL, PENROD 91, DN654067 AND ARE TO BE COMPLIED WITH BY 23 FEB 85.
Condition: Unknown
Due 23 January 1985
Resolved 23 January 1985
Lifesaving
Issued 23 January 1985 Resolved
RENEW 12 EACH PARACHUTE FLARES IN #1 LIFEBOAT 46 CFR 108.503.
Condition: Unknown
Due 23 January 1985
Resolved 23 January 1985
Unknown
Issued 26 January 1984 Resolved
PROVIDE TWO OXYGEN/EXPLOSIVE METERS FOR THE FIREMEN'S OUTFITS.
Condition: Unknown
Due 26 January 1984
Resolved 26 January 1984
Unknown
Issued 26 January 1984 Resolved
ENSURE THE PROPER OPERATION OF THE LOW LUBE OIL SHUTDOWN ON THE EMERGENCY GENERATOR.
Condition: Unknown
Due 26 January 1984
Resolved 26 January 1984
Unknown
Issued 26 January 1984 Resolved
UPON COMPLETION OF COAST GUARD REVIEW, PROVIDE A STAMPED COPY OF THE VESSEL'S FIRE AND SAFETY CONTROL PLAN.
Condition: Unknown
Due 26 January 1984
Resolved 26 January 1984
Unknown
Issued 26 January 1984 Resolved
THE FOLLOWING DEFICIENCIES ARE FOR THE PENROD 91, DN654067.
Condition: Unknown
Due 26 January 1984
Resolved 26 January 1984

Ownership record