MAURY USCG vessel records Sign in
← All vessels

HURRICANE

HURRICANE is a 1945 mobile offshore drilling unit. The Coast Guard has recorded 2 inspections since 1984, most recently in September 1986, along with 15 deficiencies.

Records from 1984 to 1986. Most recent: inspection, 12 September 1986.

Built
1945
Last inspected
12 September 1986
Documentation
Not in the documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

5348574 View on MarineTraffic leaves Maury; a third-party site, nothing from it is stored here
Flag
SINGAPORE
—
Maury page id
psix-54774

Inspections, by type

…with no type recorded2
Years with a record 2 calendar years (1984–1986)
The 2 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

This record may be incomplete: the most recent inspection recorded for this vessel was 40 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Offshore class in Maury's sources begin in 1978.

Documentation record

Tonnage as PSIX records it5508 - Regulatory (Subpart C or D), Gross Ton
3653 - Regulatory (Subpart C or D), Net Ton
10536 - Dead Weight, Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.

Radio station licence

No FCC ship-station licence is recorded against this Official Number in the file of 6 September 2026. That is a fact about the licence file, not about the radio.

A report is not offered for this hull: Its record holds only 1 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. Reports.

Inspection history · 2

12 September 1986 Type not recorded
No type recorded · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1308121
27 October 1984 Type not recorded
No type recorded · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 976183

Deficiency record · 15

Unknown
Issued 27 October 1984 Resolved
WEIGHT TEST BOTH PORT AND STARBOARD LIFEBOATS.
Condition: Unknown
Due 31 July 1985
Resolved 18 May 2002
Resolution: MISLE Maintenance - Resolved all open deficiencies issued prior to 6/1/1997 where activity was closed and deficiency due date was past
Unknown
Issued 27 October 1984 Resolved
DRILL FLOOR ELECTRICAL BOXES IN THE CONTROL STAND SHALL BE MADE SUITABLE FOR THE HAZARDOUS LOCATION
Condition: Unknown
Due 27 October 1984
Resolved 27 October 1984
Unknown
Issued 27 October 1984 Resolved
ALL 6 "P" TANKS ARE TO BE FITTED WITH APPROVED RELIEF VALVES SET NOT TO EXCEED THE MAWP OF THE TANKS.
Condition: Unknown
Due 31 July 1985
Resolved 18 May 2002
Resolution: MISLE Maintenance - Resolved all open deficiencies issued prior to 6/1/1997 where activity was closed and deficiency due date was past
Unknown
Issued 27 October 1984 Resolved
REPLACE THE BATTERIES TO THE KOOMEY BOP EMERGENCY 115 VOLT DC BATTERY OPERATED SYSTEM. TEST SATISFACTORILY.
Condition: Unknown
Due 31 July 1985
Resolved 18 May 2002
Resolution: MISLE Maintenance - Resolved all open deficiencies issued prior to 6/1/1997 where activity was closed and deficiency due date was past
Unknown
Issued 27 October 1984 Resolved
PROVE ALL WATERTIGHT DOOR INDICATOR ELECTRICAL BOXES WITHIN THE MUD PIT AREA ARE SUITABLE FOR THE HAZARDOUS LOCATION.
Condition: Unknown
Due 31 July 1985
Resolved 18 May 2002
Resolution: MISLE Maintenance - Resolved all open deficiencies issued prior to 6/1/1997 where activity was closed and deficiency due date was past
Unknown
Issued 27 October 1984 Resolved
TEST THE SIX REMAINING HIGH PRESSURE TENSIONER SYSTEM AIR RECEIVER RELIEF VALVES.
Condition: Unknown
Due 31 July 1985
Resolved 18 May 2002
Resolution: MISLE Maintenance - Resolved all open deficiencies issued prior to 6/1/1997 where activity was closed and deficiency due date was past
Unknown
Issued 27 October 1984 Resolved
VESSEL DRYDOCKING HAS BEEN EXTENDED DUE TO THE VESSEL LAY-UP STATUS. THE VESSEL SHALL BE DRYDOCKED PRIOR TO THE VESSEL DEPARTING FROM THE PORT OF SINGAPORE.
Condition: Unknown
Due 31 July 1985
Resolved 18 May 2002
Resolution: MISLE Maintenance - Resolved all open deficiencies issued prior to 6/1/1997 where activity was closed and deficiency due date was past
Unknown
Issued 27 October 1984 Resolved
HYDROSTATICALLY TEST OR INTERNALLY EXAMINE THE 11 RISER TENSIONER SYSTEM AIR RECEIVER.
Condition: Unknown
Due 31 July 1985
Resolved 18 May 2002
Resolution: MISLE Maintenance - Resolved all open deficiencies issued prior to 6/1/1997 where activity was closed and deficiency due date was past
Unknown
Issued 27 October 1984 Resolved
THE MUD PUMP COMPARTMENT SHALL BE ISOLATED FROM THE ACTIVE MUD PIT ROOM BY AN AIR LOCK OR THE ELECTRICAL EQUIPMENT WITHIN THE MUD PUMP COMPARTMENT SHALL BE MADE SUITABLE FOR THE HAZARDOUS LOCATION AS PER 46CFR108.175.
Condition: Unknown
Due 31 July 1985
Resolved 18 May 2002
Resolution: MISLE Maintenance - Resolved all open deficiencies issued prior to 6/1/1997 where activity was closed and deficiency due date was past
Unknown
Issued 27 October 1984 Resolved
CONDUCT A FIRE AND ABANDON SHIP DRILL.
Condition: Unknown
Due 31 July 1985
Resolved 18 May 2002
Resolution: MISLE Maintenance - Resolved all open deficiencies issued prior to 6/1/1997 where activity was closed and deficiency due date was past
Unknown
Issued 27 October 1984 Resolved
CG-835 ITEM 1 ISSUED BY [name withheld], HI DATED 12JAN84 REMAINS UNSATISFACTORY. THE GENERAL ALARM BELLS ARE 24 VOLT CROUSE HINDS AND MUST BE UL, FM, OR CSA APPROVED.
Condition: Unknown
Due 31 July 1985
Resolved 18 May 2002
Resolution: MISLE Maintenance - Resolved all open deficiencies issued prior to 6/1/1997 where activity was closed and deficiency due date was past
Unknown
Issued 27 October 1984 Resolved
THE KELLY HOSE IS TO HYDROSTATICALLY TESTED TO THE MAWP OF THE SYSTEM.
Condition: Unknown
Due 31 July 1985
Resolved 18 May 2002
Resolution: MISLE Maintenance - Resolved all open deficiencies issued prior to 6/1/1997 where activity was closed and deficiency due date was past
Unknown
Issued 27 October 1984 Resolved
REPLACE ALL OUTDATED LINE THROWING APPLIANCE IMPULSE ROCKETS.
Condition: Unknown
Due 31 July 1985
Resolved 18 May 2002
Resolution: MISLE Maintenance - Resolved all open deficiencies issued prior to 6/1/1997 where activity was closed and deficiency due date was past
Unknown
Issued 27 October 1984 Resolved
REPLACE ALL OUTDATED HAND-HELD RED PARCHUTE FLARES.
Condition: Unknown
Due 31 July 1985
Resolved 18 May 2002
Resolution: MISLE Maintenance - Resolved all open deficiencies issued prior to 6/1/1997 where activity was closed and deficiency due date was past
Unknown
Issued 27 October 1984 Resolved
ALL LIFEBOAT EQUIPMENT SHALL BE STRIPPED FROM BOTH LIFEBOATS FOR INSPECTION. CHANGE THE DIESEL FUEL IN BOTH MOTOR LIFEBOATS. OPERATIONALLY TEST THE DAVITS FOR BOTH LIFEBOATS IN THE PRESENCE OF A COAST GUARD INSPECTOR.
Condition: Unknown
Due 31 July 1985
Resolved 18 May 2002
Resolution: MISLE Maintenance - Resolved all open deficiencies issued prior to 6/1/1997 where activity was closed and deficiency due date was past

Ownership record