MAURY USCG vessel records
← All vessels

BARGE 500-2

Built
1983
Last inspected
13 March 2026
Documentation
Valid · NVDC file of 10 August 2026
Controls
None recorded without a removal date

Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Miscellaneous Vessel class in Maury's sources begin in 2016.

Inspection record

Last inspected 13 March 2026
…with no type recorded3
Operational controls None recorded without a removal date
Years with a record 11 calendar years (2016–2026)
Every line above is a count of records the US Coast Guard wrote, or a date it recorded. A blank resolution means none was recorded in this data; it does not establish that a deficiency is outstanding. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Identity

WBM6504
Flag
UNITED STATES
Maury page id
psix-54775

Documentation record

Registered dimensions (L × B × D)400.0 ft × 105.0 ft × 20.0 ft
Registered tonnagegross 7,171 / net 7,171
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderFMC CORP MARINE & RAIL EQUIP DIV · PORTLAND, OR, UNITED STATES · built 1983
Hull materialSteel
PropulsionNone
Hull shapeUNSPECIFIED
Hull configurationUNSPECIFIED
Hailing portSAN FRANCISCO, CA
Endorsements, as the file codes themcw_un, reg
DocumentationValid · issued 17 June 2026 · expires 31 July 2027
Service, as the file records itOil Recovery
Hull formbarge (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it7171 - Regulatory (Subpart C or D), Net Ton
7171 - Regulatory (Subpart C or D), Gross Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 August 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
Professional
The full record for this vessel

Behind this panel: 44 inspections, each with its date, unit and type; 43 deficiencies with the resolution recorded against each; operational controls, none recorded without a removal date; no tow-unit appearances recorded; no other recorded names; the documentation record: dimensions, tonnage, builder, hailing port and endorsements. Every line is a record the Coast Guard wrote; the counts above are the same counts as in the summary, and they are free.

Professional is $39 a month or $299 a year, or $19.99 a month locked for life at the founding rate, for the first 200 subscribers. It unlocks every detail section on every vessel page, fleet watch tied to your account, and ownership records on request. Already a subscriber? Sign in.

Maury does not score, rate or grade vessels, at any price.

Vessel history report
Every record for this hull, in one document — $299

Every recorded inspection, 1972 to 2026, in one chronology · every deficiency, with system, dates and resolution · operational controls imposed and removed · every name this hull has been recorded under · the vessels it was inspected alongside, and when · how its record compares with hulls of similar age and size, as a fact about the population and never a judgement about this vessel.

Read one first, in full: a forty-year chronology · a hull that changed operators four times · the sparse case, shown as an example, not for sale.

This report is in development and is not for sale yet. There is no date, and nothing is charged. Leave an email and we will tell you when it exists, once.

Inspection history · 44

13 March 2026 Annual Inspection · MTSA/ISPS Verification · Administrative Inspection · Deficiency Check
Physical examination · Marine Safety Unit Valdez · USCG Arctic District (CGD-A) · Activity 8314748
10 October 2025 Internal Structural Exam · Underwater Inspection in lieu of Drydock · Cargo Tank Internal
Physical examination · Marine Safety Unit Valdez · USCG Arctic District (CGD-A) · Activity 8254669
22 May 2025 Deficiency Check
Physical examination · Marine Safety Unit Valdez · USCG Arctic District (CGD-A) · Activity 8140982
15 May 2025 Deficiency Check
Physical examination · Marine Safety Unit Valdez · USCG Arctic District (CGD-A) · Activity 8136632
31 March 2025 Deficiency Check · MTSA/ISPS Verification · COI Inspection
Physical examination · Marine Safety Unit Valdez · USCG Arctic District (CGD-A) · Activity 8102665
2 January 2025 Administrative Inspection
Administrative · Marine Safety Unit Valdez · USCG Arctic District (CGD-A) · Activity 8056893
5 September 2024 Deficiency Check · In-Service Inspection · Administrative Inspection
Physical examination · Detached Duty Office Seward · USCG Arctic District (CGD-A) · Activity 7997461
26 June 2024 Deficiency Check
Physical examination · Marine Safety Unit Valdez · USCG Arctic District (CGD-A) · Activity 7943251
22 May 2024 Damage Survey
Physical examination · Marine Safety Unit Valdez · USCG Arctic District (CGD-A) · Activity 7922008
15 April 2024 MTSA/ISPS Verification · Annual Inspection · Deficiency Check
Physical examination · Marine Safety Unit Valdez · USCG Arctic District (CGD-A) · Activity 7895489
11 December 2023 Deficiency Check
Physical examination · Marine Safety Unit Valdez · USCG Arctic District (CGD-A) · Activity 7837776
28 June 2023 Deficiency Check · Administrative Inspection
Physical examination · Marine Safety Unit Valdez · USCG Arctic District (CGD-A) · Activity 7727454
14 June 2023 Administrative Inspection · Periodic Inspection
Physical examination · Marine Safety Unit Valdez · USCG Arctic District (CGD-A) · Activity 7715387
13 February 2023 Underwater Inspection in lieu of Drydock · Internal Structural Exam · Cargo Tank Internal · Drydock Exam
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 7631284
31 October 2022 Administrative Inspection
Administrative · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 7590761
22 June 2022 Deficiency Check
Physical examination · Marine Safety Unit Valdez · USCG Arctic District (CGD-A) · Activity 7484465
16 June 2022 Administrative Inspection
Administrative · Marine Safety Unit Valdez · USCG Arctic District (CGD-A) · Activity 7479695
25 May 2022 Administrative Inspection
Administrative · Marine Safety Unit Valdez · USCG Arctic District (CGD-A) · Activity 7459303
25 April 2022 In-Service Inspection
Physical examination · Marine Safety Unit Valdez · USCG Arctic District (CGD-A) · Activity 7438178
24 March 2022 Annual Inspection · Administrative Inspection
Physical examination · Marine Safety Unit Valdez · USCG Arctic District (CGD-A) · Activity 7419114
13 January 2022 Type not recorded
No type recorded · Marine Safety Unit Valdez · USCG Arctic District (CGD-A) · Activity 7388522
25 February 2021 Administrative Inspection · Annual Inspection
Physical examination · Marine Safety Unit Valdez · USCG Arctic District (CGD-A) · Activity 7146513
7 December 2020 Cargo Tank Internal · Underwater Inspection in lieu of Drydock · Internal Structural Exam
Physical examination · Marine Safety Unit Valdez · USCG Arctic District (CGD-A) · Activity 7111753
19 October 2020 Deficiency Check
Physical examination · Marine Safety Unit Valdez · USCG Arctic District (CGD-A) · Activity 7081672
28 September 2020 Deficiency Check
Physical examination · Marine Safety Unit Valdez · USCG Arctic District (CGD-A) · Activity 7067330
23 September 2020 Deficiency Check · Damage Survey
Physical examination · Marine Safety Unit Valdez · USCG Arctic District (CGD-A) · Activity 7063913
23 September 2020 Type not recorded
No type recorded · Marine Safety Unit Valdez · USCG Arctic District (CGD-A) · Activity 7066977
17 September 2020 Administrative Inspection
Administrative · Marine Safety Unit Valdez · USCG Arctic District (CGD-A) · Activity 7060173
29 June 2020 COI Inspection
Physical examination · Marine Safety Unit Valdez · USCG Arctic District (CGD-A) · Activity 6985873
26 May 2020 Administrative Inspection
Administrative · Commandant (CG-CVC) · Activity 6960813
18 April 2020 Administrative Inspection
Administrative · Marine Safety Unit Valdez · USCG Arctic District (CGD-A) · Activity 6940883
28 February 2019 Deficiency Check · Annual Inspection
Physical examination · Marine Safety Unit Valdez · USCG Arctic District (CGD-A) · Activity 6638389
21 February 2019 Construction Oversight
Physical examination · Marine Safety Unit Valdez · USCG Arctic District (CGD-A) · Activity 6645424
21 June 2018 Administrative Inspection
Administrative · Marine Safety Unit Valdez · USCG Arctic District (CGD-A) · Activity 6451808
28 March 2018 Annual Inspection
Physical examination · Marine Safety Unit Valdez · USCG Arctic District (CGD-A) · Activity 6381538
22 January 2018 Drydock Exam · Internal Structural Exam
Physical examination · Marine Safety Unit Portland OR · USCG Northwest District (CGD-NW) · Activity 6341745
28 September 2017 Administrative Inspection
Administrative · Marine Safety Unit Valdez · USCG Arctic District (CGD-A) · Activity 6277527
16 May 2017 Annual Inspection · Deficiency Check
Physical examination · Marine Safety Unit Valdez · USCG Arctic District (CGD-A) · Activity 6148866
28 October 2016 Type not recorded
No type recorded · Marine Safety Unit Valdez · USCG Arctic District (CGD-A) · Activity 6032003
2 June 2016 Deficiency Check
Physical examination · Marine Safety Unit Valdez · USCG Arctic District (CGD-A) · Activity 5895778
26 May 2016 Deficiency Check
Physical examination · Marine Safety Unit Valdez · USCG Arctic District (CGD-A) · Activity 5887907
21 April 2016 Damage Survey · Deficiency Check
Physical examination · Marine Safety Unit Valdez · USCG Arctic District (CGD-A) · Activity 5860310
2 March 2016 Annual Inspection
Physical examination · Marine Safety Unit Valdez · USCG Arctic District (CGD-A) · Activity 5825755
8 February 2016 Underwater Inspection in lieu of Drydock · Internal Structural Exam
Physical examination · Marine Safety Unit Valdez · USCG Arctic District (CGD-A) · Activity 5811728

Deficiency record · 43

13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Auxiliary engine
Issued 7 April 2025 Resolved
Each generator prime mover must have an over speed device that is independent of the normal operating governor. So that the speed cannot exceed the maximum rated speed by more than 15%. Crew is unable to test the over speed. CVC-WI-011(1) allows for this to only be tested every 5 years. 46 CFR 111.12-1(b)
Condition: Design Flaw
Action required: 50 - Rectify deficiencies w/in 30 days
Due 7 May 2025
Resolved 22 May 2025
Resolution: Overspeed protection tested satisfactory.
04 - Emergency Systems › N/A - No Subsystem › Emergency, lighting, batteries and switches
Issued 7 April 2025 Resolved
At least one (emergency) light in each space where a person may be maintaining, repairing, or operating equipment. Vessel does not have any emergency lighting in the engineering space on board. 46 CFR 112.15-1(f)
Condition: Design Flaw
Action required: 50 - Rectify deficiencies w/in 30 days
Due 7 May 2025
Resolved 9 April 2025
Resolution: Elight has been installed.
07 - Fire Safety › N/A - No Subsystem › Division - decks, bulkheads and penetrations
Issued 7 April 2025 Resolved
Bulkheads of galleys, paint and lamp lockers shall be of "A" Class construction. The paint locker's door was busted and would not close as intended. No flammable materials shall be kept in this space until repaired/ replaced. 46 CFR 32.57-10(b)
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Due 7 April 2025
Resolved 7 April 2025
Resolution: Replaced paint locker
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Auxiliary engine
Issued 7 April 2025 Resolved
Prime movers must meet section 58.01-5 and 46 CFR subpart 58.10. The number 1 generator was out of commission, and unable to test. 46 CFR 111.12-1
Action required: 50 - Rectify deficiencies w/in 30 days
Due 7 May 2025
Resolved 22 May 2025
Resolution: Tested generator, all sat
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 31 March 2025 Resolved
During each inspection or re-inspection for certification, all wing voids, rakes, cofferdams and other void spaces on tank barges must be opened and checked from on-deck for the presence of water. Unable to open aft rakes due to water on deck. O/O shall make voids available for inspection. 46 CFR 31.10-21(b)
Condition: Design Flaw
Action required: 50 - Rectify deficiencies w/in 30 days
Due 7 May 2025
Resolved 9 April 2025
Resolution: Inspected the aft rakes. All Sat
02 - Structural Conditions › N/A - No Subsystem › Openings to cargo area, doors, ... scuttles
Issued 5 September 2024 Resolved
No extensive alterations involving the safety of a tank vessel either in regard to hull or machinery shall be made without the approval of the Commandant. Before such alterations are carried out, copies of plans and specifications for the work involved shall be forwarded to the Officer in Charge, Marine Inspection, in whose zone the repairs will be made, for submission to Headquarters for approval. Manholes and hatches are being installed in forward voids and cargo tanks 1C/2C without CG approved plans. 46CFR31.10-25
Action required: 50 - Rectify deficiencies w/in 30 days
Due 5 October 2024
Resolved 1 October 2024
Resolution: MSC review complete under letter C1-2303672.
11 - Life Saving Appliances › N/A - No Subsystem › Other (life saving)
Issued 15 April 2024 Resolved
Each rescue boat must be marked with the (home) port on the stern. Vessel had old home port listed on vessel. 46 CFR 199.176(a)(1)ii
Condition: Invalid
Action required: 50 - Rectify deficiencies w/in 30 days
Due 15 May 2024
Resolved 17 April 2024
Resolution: Boat was painted
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 15 April 2024 Resolved
Each outlet or junction box must be suitable for the environment in which it is installed. Junction box found IWO Port side cable run on deck was found to have a broken cover with a plastic bag wrapped around it. 46 CFR 111.81-1(f)
Action required: 50 - Rectify deficiencies w/in 30 days
Due 15 May 2024
Resolved 16 April 2024
Resolution: Fixed
11 - Life Saving Appliances › N/A - No Subsystem › Helicopter landing and pick-up area
Issued 15 April 2024 Resolved
Each helicopter deck must be marked with; (i) The unit's identification. (ii) A continuous line 40 centimeters (16") wide on hte perimeter; and (iii) Aiming circles as may be appropriate considering deck configuration, helicopter type and operational requirements. (b) All markings must be in a contrasting color. Correct prior to flight ops. 46 CFR 108.241 NVIC 9-81
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 16 June 2024
Resolved 23 April 2024
Resolution: Helicopter pad was painted
07 - Fire Safety › N/A - No Subsystem › Fixed fire extinguishing installation
Issued 15 April 2024 Resolved
Vessels of 1,000 GT requiring a fire main system shall be able to deliver water at approximately 50 psi. One of the fire stations located closest to the helipad was clogged. Crew was able to clear system after inspectors departed. 46 CFR 95.10-5 (b)&(c)
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 15 April 2024
Resolved 15 April 2024
Resolution: Cleared out clogged line
01 - Certificates & Documentation › 012 - Crew Certificates › Medical certificate
Issued 14 June 2023 Resolved
A person may not employ or engage an individual in a position required to hold an MMC unless that individual maintains a current medical certificate. One of the Able Seaman's medical certificate was expired. Vessel is no-sailed until the full compliment of crew is on board. 46 CFR 15.401(c)
Condition: Invalid
Action required: 60 - Rectify deficiencies prior to movement
Due 14 June 2023
Resolved 14 June 2023
Resolution: Vessel brought on a new crew member.
01 - Certificates & Documentation › 011 - Ships Certificates › Tonnage certificate
Issued 14 June 2023 Resolved
If an international Tonnage Certificate is not issued for a vessel measured under this part, the RO must issue a U.S. Tonnage Certificate. Vessel could not locate a tonnage cert. 46 CFR 69.69(b)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 28 June 2023
Resolved 11 December 2023
Resolution: Received ITC
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 14 June 2023 Resolved
It shall be the duty of the owner, master or person in charge, to see that the vessel's firefighting equipment is at all times ready for use. 04 hose nozzles were found defective. 46 CFR 97.15-60 (a)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 28 June 2023
Resolved 23 August 2023
Resolution: Sent text with pictures of new nozzels
04 - Emergency Systems › N/A - No Subsystem › Emergency, lighting, batteries and switches
Issued 14 June 2023 Resolved
Emergency lighting and power systems are to be operated and inspected at least once a week. The majority of the emergency lights did not operate when the vessel went dark, nor when tested locally. 46 CFR 97.15-30 (a)
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 28 June 2023
Resolved 28 June 2023
Resolution: Vessel rep provided requsition and reciept of 24 batteries for emergency lights.
08 - Alarms › N/A - No Subsystem › Fire alarm
Issued 14 June 2023 Resolved
Fire detection and alarm system must notify crew and passengers of a fire when appropriate. All the fire detectors inspected were expired by over a year. 46 CFR 95.05-1 (a) 46 CFR 76.27-5(e)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 28 June 2023
Resolved 28 June 2023
Resolution: All smoke detectors were replaced.
01 - Certificates & Documentation › 013 - Documents › Fire control plan - all
Issued 14 June 2023 Resolved
Fire control plans required by 97.36-1 shall be kept up to date. Vessel has multiple versions of the FCP. 46 CFR 97.36-1 (c)
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Due 28 June 2023
Resolved 28 June 2023
Resolution: Old fire control plans were removed. Only one fire control plan remains onboard.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 14 June 2023 Resolved
It shall be the duty of the owner, master or person in charge, to see that the vessel's firefighting equipment is at all times ready for use. One fire extinguisher was found, requiring servicing. 46 CFR 97.15-60 (a)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 28 June 2023
Resolved 28 June 2023
Resolution: Under-charged fire extinguisher in crew room 8-a was replaced with a new one.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 14 June 2023 Resolved
At least one-half the total number of lifebuoys on a vessel must be fitted with a self activating light. One light was found to not operate as intended. 46 CFR 199.70 (a) 3 ii
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 28 June 2023
Resolved 15 June 2023
Resolution: Crew fixed the wires
11 - Life Saving Appliances › N/A - No Subsystem › Immersion suits
Issued 14 June 2023 Resolved
Each immersion suite marked in such as to identify the person or vessel. Suite discovered to have old name on it. 46 CFR 199.70(c) 3
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 28 June 2023
Resolved 15 June 2023
Resolution: suite isnowmarked with vessel name
15 - Safety Management Systems (ISM) › N/A - No Subsystem › Maintenance of the ship and equipment
Issued 14 June 2023 Resolved
Every tank ship shall have the name marked upon each bow and upon the stern, and the home port shall also be marked upon the stern. Vessel does not have the correct home port listed. 46 CFR 32.05-10
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 14 July 2023
Resolved 23 October 2023
Resolution: THe COD was issued with the correct hailing port. Now an amended COI will be issued.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 14 June 2023 Resolved
Each lifebuoy must be marked with the name of the vessel and the name of the port. Lifebuoy's had wrong port. 46 CFR 199.70 (a) 3
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 14 July 2023
Resolved 28 June 2023
Resolution: Re-marked all liferings with Valdez, AK as homeport.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 14 June 2023 Resolved
Containers, brackets, racks and other similar stowage locations for lifesaving equipment must be marked with symbols in accordance with IMO Resolution A 760(18) indicating the device stowed in that location. Lifesaving equipment was not marked properly. 46 CFR 199.178(a)
Action required: 50 - Rectify deficiencies w/in 30 days
Due 14 July 2023
Resolved 23 October 2023
Resolution: provided to pictures of new signs.
15 - Safety Management Systems (ISM) › N/A - No Subsystem › Other (ISM)
Issued 14 June 2023 Resolved
With the totality of deficiencies found, an internal audit into the emergency systems(maintenance & testing), along with Security shall be completed. 46 CFR 31.10
Action required: 50 - Rectify deficiencies w/in 30 days
Due 14 July 2023
Resolved 28 June 2023
Resolution: Vessel provided internal audit, complete with findings and lessons learned.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Auxiliary engine
Issued 25 April 2022 Resolved
When alteration or repair of boilers, pressure vessels, machinery, safety valves or piping systems becomes necessary, the work shall be done under the cognizance of the Officer in Charge Marine Inspection. It shall be done in accordance with the regulations in effect at the time such vessel or installation was contracted for or built (whichever is latest), or in accordance with the regulations in effect for new construction. Casualty on #1 Auxiliary Generator requires repair and/or replacement of unit. Repair/replace unit.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 26 May 2022
Resolved 22 June 2022
08 - Alarms › N/A - No Subsystem › General alarm
Issued 24 March 2022 Resolved
General emergency alarm signal must be located in a machinery space. General alarm and light in generator space did not work. Until general alarm is repaired, post a crew member outside generator space anytime someone enters space to be so they can alert them in the event of general alarm.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 25 April 2022
Resolved 7 April 2022
Resolution: New alert system was installed for GE in generator connex box
07 - Fire Safety › N/A - No Subsystem › Fire-dampers
Issued 23 September 2020 Resolved
Generator room fire dampener doors are rusted, do not close properly or are missing. Make proper repairs prior to departure.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 23 September 2020
Resolution: New dampener plate was installed were it was missing and all other dampener plates moved freely with added securing locks installed.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 23 September 2020 Resolved
As a result of a fire in STBD generator windings a total loss of the generator has occurred. Prove proper operation of STDB generator in the presence of a USCG Marine Inspector.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 23 October 2020
Resolved 19 October 2020
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 23 September 2020 Resolved
Provide extra fire extinguishers on deck and secured in the vicinity of generator pack used as the back up generator.
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 23 October 2020
Resolved 19 October 2020
07 - Fire Safety › N/A - No Subsystem › Fire pumps and its pipes
Issued 29 June 2020 Resolved
Make starboard fire pump operational. 46 CFR 31.10-18(f)
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Due 20 July 2020
Resolved 28 September 2020
Resolution: Conducted satisfactory test of #2 fire pump.
11 - Life Saving Appliances › N/A - No Subsystem › Other (life saving)
Issued 28 February 2019 Resolved
AFFIX ON EACH SIDE OF RESCUE BOAT THE NAME OF THE VESSEL IN BLOCK LETTERING AND THE NAME OF THE HOME PORT ON THE STERN OF THE VESSEL TO COMPLY WITH 46 CFR 67.123. IAW 46 CFR 199.176(a)(1)(i) AND (ii)
Action required: 50 - Rectify deficiencies w/in 30 days
Due 1 April 2019
Resolved 15 March 2019
Fire Fighting › Fire Pumps › Power Source
Issued 28 September 2017 Resolved
Make #1 fire pump operational.
Condition: Invalid
Action required: 705 - Other - as specified
Due 5 October 2017
Resolved 30 September 2017
Engineering › Diesel Engine (auxiliary) › Piping (exhaust)
Issued 2 June 2017 Resolved
Repair exhasut leak on #1 generator.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 16 June 2017
Resolved 8 June 2017
Engineering › Diesel Engine (auxiliary) › Cylinder
Issued 2 June 2017 Resolved
repair oil leak on #1 generator.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 16 June 2017
Resolved 16 June 2017
Construction/Loadline › Structures › Machinery Space Opening
Issued 2 June 2017 Resolved
Repair leak in the generator that is allowing water to enter.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 16 June 2017
Resolved 8 June 2017
Construction/Loadline › Structures › Machinery Space Opening
Issued 2 June 2017 Resolved
Remove all standing water within the generator space.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 9 June 2017
Resolved 8 June 2017
Engineering › Diesel Engine (auxiliary) › Emergency shutdown
Issued 2 June 2017 Resolved
Label shutdowns for generators #1 & #2, located outside of the generator space.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 9 June 2017
Resolved 8 June 2017
Accommodation/Occupational Safety › Occupational Safety › Tripping/Falling Hazard
Issued 2 June 2017 Resolved
Secure refrigerators to prevent falling in heavy seas.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 9 June 2017
Resolved 8 June 2017
Communications › Alarms/Indicators › General Alarm
Issued 2 June 2017 Resolved
Label visual general alarms in the generator space.
Condition: Invalid
Action required: 705 - Other - as specified
Due 9 June 2017
Resolved 8 June 2017
Communications › Visual Communication › Warning Sign (radio room)
Issued 2 June 2017 Resolved
remove CO2 placard from the generator space.
Condition: Invalid
Action required: 705 - Other - as specified
Due 9 June 2017
Resolved 8 June 2017
Engineering › Fuel Oil Service System › Valve
Issued 2 June 2017 Resolved
Make clear operating instructions for the main fuel tank emergency shutoff to indicate open and closed.
Condition: Invalid
Action required: 705 - Other - as specified
Due 9 June 2017
Resolved 8 June 2017
Fire Fighting › Fire Pumps › Pumpshaft
Issued 16 May 2017 Resolved
Make #2 fire pump operational.
Condition: Invalid
Action required: 705 - Other - as specified
Due 8 June 2017
Resolved 2 June 2017
Fire Fighting › Fire Main › Condition
Issued 26 May 2016 Resolved
Crop and renew pin hole leaks on fire main. 46 CFR 30.01-10
Action required: 705 - Other - as specified
Due 8 June 2016
Resolved 2 June 2016
Construction/Loadline › Hull › Bracket
Issued 21 April 2016 Resolved
Make proper repairs to port deck crane pedestal prior to use.
Action required: 705 - Other - as specified
Due 21 April 2016
Resolved 22 April 2016

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.