MAURY USCG vessel records Sign in
← All vessels

VIKING SEAHORSE

VIKING SEAHORSE is a 1983 offshore supply vessel. The Coast Guard has recorded 32 inspections since 1983, most recently in July 1995, along with 78 deficiencies.

Records from 1983 to 1995. Most recent: inspection, 21 July 1995.

Built
1983
Last inspected
21 July 1995
Documentation
Not in the documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

8207549 View on MarineTraffic leaves Maury; a third-party site, nothing from it is stored here
Flag
BELIZE
—
Maury page id
psix-54780

Inspections, by type

…with no type recorded5
Years with a record 12 calendar years (1983–1995)
The 32 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

This record may be incomplete: the most recent inspection recorded for this vessel was 31 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Offshore class in Maury's sources begin in 1978.

Documentation record

Tonnage as PSIX records it275 - Regulatory (Subpart C or D), Gross Ton
187 - Regulatory (Subpart C or D), Net Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.

Radio station licence

No FCC ship-station licence is recorded against this Official Number in the file of 6 September 2026. That is a fact about the licence file, not about the radio.

A report is not offered for this hull: Its record holds only 2 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. Reports.

Inspection history · 32

21 July 1995 Administrative
Administrative · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 880470
17 August 1994 Hull Examination
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 843031
15 February 1994 MARPOL Annex V Examination · Re-Inspection
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1165807
19 October 1993 Deficiency Check
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1157330
18 August 1993 Deficiency Check
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 825922
12 February 1993 COI Inspection
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 833454
21 November 1991 Re-Inspection
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 961422
19 September 1991 Deficiency Check
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 936857
28 July 1991 Hull Examination
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1308192
24 July 1991 Administrative
Administrative · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1253969
7 June 1991 Administrative
Administrative · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 937287
7 June 1991 Administrative
Administrative · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 937427
28 February 1991 Deficiency Check
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1237643
11 December 1990 Administrative
Administrative · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1236463
25 November 1990 COI Inspection
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 908249
6 August 1990 Hull Examination
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1234599
6 December 1989 Re-Inspection
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 921283
3 August 1989 Deficiency Check
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 907859
8 December 1988 COI Inspection
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1037271
8 December 1988 MARPOL Annex II Examination
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1346218
11 January 1988 Re-Inspection
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1011627
10 January 1988 MARPOL Annex II Examination
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1013016
22 July 1987 Hull Examination
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1028903
26 June 1987 Deficiency Check
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1320391
20 January 1987 Type not recorded
No type recorded · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1007065
12 January 1987 COI Inspection · Drydock Extension
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1315592
12 January 1987 Administrative
Administrative · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1318536
30 January 1986 Re-Inspection
Physical examination · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1301085
15 January 1985 Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 979593
25 April 1984 Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 973097
24 March 1983 Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1275125
18 February 1983 Type not recorded
No type recorded · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1277749

Deficiency record · 78

Lifesaving
Issued 17 August 1994 Resolved
SERVICE BOTH LIFERAFTS AND SEND COPY OF CERTIFICATES TO [name withheld].
Condition: Unknown
Due 19 December 1994
Resolved 19 December 1994
Deck/Cargo
Issued 17 August 1994 Resolved
PROVIDE PROPER SIZE ANCHOR CHAIN FOR PORT ANCHOR. (1 1/4" TO 1 1/2")
Condition: Unknown
Due 30 October 1994
Resolved 18 May 2002
Resolution: MISLE Maintenance - Resolved all open deficiencies issued prior to 6/1/1997 where activity was closed and deficiency due date was past
Navigation
Issued 17 August 1994 Resolved
PROVIDE AN UPGRADED CLASS A EPIRB OR DOCUMENTATION THAT INSTALLED EPIRB MEETS CURRENT FCC STANDARDS.
Condition: Unknown
Due 30 October 1994
Resolved 18 May 2002
Resolution: MISLE Maintenance - Resolved all open deficiencies issued prior to 6/1/1997 where activity was closed and deficiency due date was past
Fire Fighting
Issued 17 August 1994 Resolved
PROVE PROPER OPERATION OF FIREPUMP PRESSURE GAUGE ON BRIDGE.
Condition: Unknown
Due 30 October 1994
Resolved 18 May 2002
Resolution: MISLE Maintenance - Resolved all open deficiencies issued prior to 6/1/1997 where activity was closed and deficiency due date was past
Navigation
Issued 15 February 1994 Resolved
PROVIDE UP TO DATE NOTICE TO MARINERS (1994).
Condition: Unknown
Due 15 February 1994
Resolved 15 February 1994
Navigation
Issued 15 February 1994 Resolved
PROVIDE A COPY OF LIGHT LISTS FOR WEST AFRICA.
Condition: Unknown
Due 15 February 1994
Resolved 15 February 1994
Navigation
Issued 15 February 1994 Resolved
PROVE PROPER OPERATION OF PORT RUNNING LIGHT RELAY ON IND PANEL.
Condition: Unknown
Due 15 February 1994
Resolved 15 February 1994
Unknown
Issued 15 February 1994 Resolved
PROVIDE A COPY OF 33CFR01-199 FOR VESSEL.
Condition: Unknown
Due 15 February 1994
Resolved 15 February 1994
Lifesaving
Issued 15 February 1994 Resolved
PROVIDE DOCUMENTATION ON CLASS A EPIRB TO SHOW THAT IT HAS BEEN UPGRADED TOMEET CURRENT FCC STANDARDS.
Condition: Unknown
Due 15 February 1994
Resolved 15 February 1994
Fire Fighting
Issued 15 February 1994 Resolved
PROVIDE ONE B-II FIRE EXTINGUISHER FOR PAINT LOCKER.
Condition: Unknown
Due 15 February 1994
Resolved 15 February 1994
Unknown
Issued 15 February 1994 Resolved
REPLACE PLUGS FOR FIXED OIL CONTAINMENT ON DECK.
Condition: Unknown
Due 15 February 1994
Resolved 15 February 1994
Lifesaving
Issued 15 February 1994 Resolved
MAKE PROPER CONNECTION TO EMERGENCY BATTERY FOR THE GEN ALARM.
Condition: Unknown
Due 15 February 1994
Resolved 15 February 1994
Lifesaving
Issued 15 February 1994 Resolved
PROVIDE BATTERY FOR EMBARKATION LIGHTS.
Condition: Unknown
Due 15 February 1994
Resolved 15 February 1994
Engineering
Issued 15 February 1994 Resolved
PROVE PROPER OPERATION OF PORT MDE REMOTE SHUTDOWN.
Condition: Unknown
Due 15 February 1994
Resolved 15 February 1994
Fire Fighting
Issued 15 February 1994 Resolved
PROVE PROPER OPERATION OF FIRE PUMP PRESSURE GAUGE ON BRIDGE.
Condition: Unknown
Due 15 February 1994
Resolved 15 February 1994
Engineering
Issued 12 February 1993 Resolved
PROVE PROPER OPERATION OF PILOT HOUSE MAIN DIESEL ENGINE SHUTDOWNS.
Condition: Unknown
Due 12 February 1993
Resolved 12 February 1993
Fire Fighting
Issued 12 February 1993 Resolved
REPLACE FIRE PUMP GAUGE LOCATED ON BRIDGE AND PROVE PROPER OPERATION.
Condition: Unknown
Due 12 February 1993
Resolved 12 February 1993
Lifesaving
Issued 12 February 1993 Resolved
PROVIDE THREE (03) COAST GUARD APPROVED TYPE I LIFE PRESERVERS. TOTAL PERSONS ALLOWED ON BOARD IS FIFTEEN (15).
Condition: Unknown
Due 20 July 1993
Resolved 20 July 1993
Navigation
Issued 12 February 1993 Resolved
PROVIDE PUBLICATION. "LAWS GOVERNING MARINE INSPECTION".
Condition: Unknown
Due 12 February 1993
Resolved 12 February 1993
Lifesaving
Issued 12 February 1993 Resolved
PROVIDE TWO (02) D.O.T. APPROVED AIR BOTTLES FOR SELF-CONTAINED BREATHING APPARATUS.
Condition: Unknown
Due 20 July 1993
Resolved 20 July 1993
Engineering
Issued 12 February 1993 Resolved
REPLACE INOPERATIVE LAMPS LOCATED IN ENGINE ROOM AND BRIDGE AUTOMATION ALARM PANELS.
Condition: Unknown
Due 20 July 1993
Resolved 20 July 1993
Documentation
Issued 12 February 1993 Resolved
PROVIDE AND USE IN ACCORDANCE WITH INSTRUCTIONS OIL RECORD BOOK.
Condition: Unknown
Due 20 July 1993
Resolved 20 July 1993
Engineering
Issued 12 February 1993 Resolved
INSTALL COAST GUARD APPROVED RELIEF VALVE ON STBD ENGINE ROOM AIR RECEIVER,MAWP SETTING OF VALVE MUST NOT EXCEED 200 PSI. TEST OPERATION OF VALVE.
Condition: Unknown
Due 20 July 1993
Resolved 20 July 1993
Fire Fighting
Issued 12 February 1993 Resolved
REPAIR MINOR WEEPS (2) ON THE NEW SECTION OF FIRE MAIN PIPING IN THE FWD TUNNEL. ALL ITEMS #1 THRU 14 ARE TO BE COMPLETED. FAX RESULTS TO [name withheld] FAX #[phone withheld].
Condition: Unknown
Due 20 July 1993
Resolved 20 July 1993
Engineering
Issued 12 February 1993 Resolved
PROVE PROPER OPERATION OF BOTH MAIN DIESEL ENGINE LUBE OIL SHUT DOWNS.
Condition: Unknown
Due 20 July 1993
Resolved 20 July 1993
Electrical
Issued 12 February 1993 Resolved
REPLACE AND PROVE PROPER OPERATION OF #1 SHIP SERVICE GENERATOR ELECTRICAL SWITCHBOARD SELECTOR SWITCH.
Condition: Unknown
Due 20 July 1993
Resolved 20 July 1993
Electrical
Issued 12 February 1993 Resolved
PROVE PROPER OPERATION OF #1 SHIP SERVICE GENERATOR LUBE OIL FAILURE ALARM.
Condition: Unknown
Due 20 July 1993
Resolved 20 July 1993
Navigation
Issued 12 February 1993 Resolved
PROVE PROPER OPERATION OF ENGINE ROOM CALL BELL AND LIGHT (SOUND POWER PHONE SYSTEM).
Condition: Unknown
Due 20 July 1993
Resolved 20 July 1993
Navigation
Issued 12 February 1993 Resolved
PROVIDE UP-TO-DATE (NEW) CHARTS FOR VESSELS' OPERATING AREA.
Condition: Unknown
Due 12 February 1993
Resolved 12 February 1993
Electrical
Issued 28 February 1991 Resolved
REPAIR OIL LEAK FOR GOVERNOR DRIVE STBD GENERATOR._x001C_ _x001C_ _x001C_ _x001C_
Condition: Unknown
Due 28 February 1991
Resolved 28 February 1991
Electrical
Issued 28 February 1991 Resolved
REPAIR OF REPLACE TACHOMETER FOR STBD GENERATOR._x001C_ _x001C_ _x001C_ _x001C_
Condition: Unknown
Due 28 February 1991
Resolved 28 February 1991
Fire Fighting
Issued 28 February 1991 Resolved
REPLACE THREE (3) ALL PURPOSE FIRE NOZZLES PRIOR TO SAILING._x001C_ _x001C_ _x001C_ _x001C_
Condition: Unknown
Due 28 February 1991
Resolved 28 February 1991
Fire Fighting
Issued 28 February 1991 Resolved
REPLACE TWO (2) 1 1/2"-50' UL APPROVED FIRE HOSES PRIOR TO SAILING._x001C_ _x001C_ _x001C_ _x001C_
Condition: Unknown
Due 28 February 1991
Resolved 28 February 1991
Fire Fighting
Issued 25 November 1990 Resolved
REPAIR OR REPLACE PRESSURE GAUGE ON FIRE PUMP.
Condition: Unknown
Due 25 November 1990
Resolved 25 November 1990
Navigation
Issued 25 November 1990 Resolved
REPAIR OR REPLACE TELEPHONE ON BRIDGE FOR INTERNAL COMMUNICATIONS SYSTEM - SOUND POWERED.
Condition: Unknown
Due 25 November 1990
Resolved 25 November 1990
Electrical
Issued 25 November 1990 Resolved
PROVE PROPER OPERATION OF OVERSPEED TRIPS ON BOTH GENERATORS.
Condition: Unknown
Due 25 November 1990
Resolved 25 November 1990
Construction/Loadline
Issued 25 November 1990 Resolved
REPLACE ALL THREE WATERTIGHT DOORS IN ENGINE ROOM WITH CLASS 1 DOORS.
Condition: Unknown
Due 25 November 1990
Resolved 25 November 1990
Engineering
Issued 25 November 1990 Resolved
REPAIR OR REPLACE BOTH RELIEF VALVES ON THE STARTING AIR PRESSURE VESSELS.
Condition: Unknown
Due 25 November 1990
Resolved 25 November 1990
Documentation
Issued 25 November 1990 Resolved
PROVIDE CURRENT RULES OF THE ROAD AND SAILING DIRECTIONS.
Condition: Unknown
Due 25 November 1990
Resolved 25 November 1990
Fire Fighting
Issued 25 November 1990 Resolved
REPLACE ALL CO2 FIRE EXTINGUISHERS IN ENGINE ROOM WITH PROPER HYDRO-DATES- STATIONS #5, 6 AND STBD ESCAPE TRUNK.
Condition: Unknown
Due 25 November 1990
Resolved 25 November 1990
Fire Fighting
Issued 25 November 1990 Resolved
REPLACE FIRE EXTINGUISHER AT STATION 7.
Condition: Unknown
Due 25 November 1990
Resolved 25 November 1990
Lifesaving
Issued 25 November 1990 Resolved
REPLACE FOUR CG APPROVED LIFE PRESERVERS.
Condition: Unknown
Due 25 November 1990
Resolved 25 November 1990
Fire Fighting
Issued 25 November 1990 Resolved
REPLACE ONE 50' -1 1/2 UL APPROVED FIRE HOSE.
Condition: Unknown
Due 25 November 1990
Resolved 25 November 1990
Deck/Cargo
Issued 6 August 1990 Resolved
REPLACE OR REPAIR ALL FOUR BULK TANK RELIEF VALVES AND PROVIDE TEST RESULTS TO [name withheld].
Condition: Unknown
Due 6 August 1990
Resolved 6 August 1990
Engineering
Issued 6 August 1990 Resolved
REPLACE BOTH PORT AND STARBOARD TAILSHAFTS BY NOT LATER THAN 31JUL91.
Condition: Unknown
Due 6 August 1990
Resolved 6 August 1990
Electrical
Issued 6 December 1989 Resolved
INSTALL GLOBES FOR LIGHT FIXTURE IN THE AFT STEERING COMPARTMENT.
Condition: Unknown
Due 6 December 1989
Resolved 6 December 1989
Electrical
Issued 6 December 1989 Resolved
PROVIDE (2) TWO GLOBES FOR LIGHTS ON FORWARD MAIN DECK GALLEY ENTRANCE.
Condition: Unknown
Due 6 December 1989
Resolved 6 December 1989
Electrical
Issued 6 December 1989 Resolved
REPAIR OVERHEAD LIGHT IN CREWS HEAD, AND INSTALL A LIGHT SWITCH FOR IT.
Condition: Unknown
Due 6 December 1989
Resolved 6 December 1989
Construction/Loadline
Issued 6 December 1989 Resolved
PROVIDE A COVER FOR THE STOVE LIGHTS AND REPAIR THE FAN OVER THE STOVE.
Condition: Unknown
Due 6 December 1989
Resolved 6 December 1989
Electrical
Issued 6 December 1989 Resolved
REPAIR OVERHEAD LIGHT IN GALLEY NEXT TO BULKHEAD.
Condition: Unknown
Due 6 December 1989
Resolved 6 December 1989
Construction/Loadline
Issued 6 December 1989 Resolved
SECURLY FASTEN THE ACTYLINE GAS BOTTLES ON PORT FORWARD MAIN DECK.
Condition: Unknown
Due 6 December 1989
Resolved 6 December 1989
Fire Fighting
Issued 6 December 1989 Resolved
REPLACE THE WASTED PAINT LOCKER MOUNTING BRACKET FOR THE FIXED CO2 SYSTEM.
Condition: Unknown
Due 6 December 1989
Resolved 6 December 1989
Deck/Cargo
Issued 8 December 1988 Resolved
MAKE AVAILABLE FOR INTERNAL AND EXTERNAL EXAMINAITON ALL (4) FOUR DRY BULK TANKS AND (2) TWO SHIPS SERVICE AIR RECEIVERS.
Condition: Unknown
Due 8 December 1988
Resolved 8 December 1988
Deck/Cargo
Issued 8 December 1988 Resolved
MAKE AVAILABLE FOR/TEST ALL (4) FOUR DRY BULK TANK RELIEF VALVES.
Condition: Unknown
Due 8 December 1988
Resolved 8 December 1988
Electrical
Issued 8 December 1988 Resolved
INSTALL PROTECTIVE GUARD FOR FAN BELT ON STARBOARD GENERATOR.
Condition: Unknown
Due 8 December 1988
Resolved 8 December 1988
Deck/Cargo
Issued 8 December 1988 Resolved
INSTALL PROTECTIVE GUARD ON BALLAST PUMP SHAFT IN ENGINE ROOM.
Condition: Unknown
Due 8 December 1988
Resolved 8 December 1988
Engineering
Issued 8 December 1988 Resolved
INSTALL PROTECTIVE GUARDS FOR SIGHT GLASSES ON PORT AND STARBOARD GENERATORCOOLANT TNAK.
Condition: Unknown
Due 8 December 1988
Resolved 8 December 1988
Accommodation/Occupational Safety
Issued 8 December 1988 Resolved
REPLACE PORT S/S AIR RECEIVER RELIEF VALVE.
Condition: Unknown
Due 8 December 1988
Resolved 8 December 1988
Engineering
Issued 8 December 1988 Resolved
MAKE OPERABLE AVIBLE ALARMS OR BRIDGE AND ENGINE ROOM, ALARM PANELS FOR GENERATORS AND MAIN ENGINES.
Condition: Unknown
Due 8 December 1988
Resolved 8 December 1988
Electrical
Issued 8 December 1988 Resolved
REPLACE LIGHT SOCKET IN CENTER 110V LIGHT IN AFTER STEERING COMPARTMENT.
Condition: Unknown
Due 8 December 1988
Resolved 8 December 1988
Electrical
Issued 8 December 1988 Resolved
INSTALL BACKING FOR CIRCUIT BREAKERS IN 480 VAC PANEL NUMBER F 418 IN ENGINE ROOM IN WAY OF GENERATOR BOARD.
Condition: Unknown
Due 8 December 1988
Resolved 8 December 1988
Lifesaving
Issued 8 December 1988 Resolved
HYDROSTATICALLY TEST VESSELS SELF CONTAINED BREATHING APPARATUS AND SPARE BOTTLE.
Condition: Unknown
Due 8 December 1988
Resolved 8 December 1988
Fire Fighting
Issued 11 January 1988 Resolved
MOUNT PORTABLE FIRE EXTINGUISHER IN STARBOARD ENGINEROOM EMERGENCY ESCAPE TRUNK IN APPROVED BRACKET.
Condition: Unknown
Due 11 January 1988
Resolved 11 January 1988
Unknown
Issued 11 January 1988 Resolved
MAKE PERMANENT REPAIRS TO BILGE PUMP DISCHARGE PIPING THAT HAS BEEN SOFT- PATCHED.
Condition: Unknown
Due 11 January 1988
Resolved 11 January 1988
Navigation
Issued 11 January 1988 Resolved
PROVE PROPER OPERATION OF PORT RADAR.
Condition: Unknown
Due 11 January 1988
Resolved 11 January 1988
Navigation
Issued 11 January 1988 Resolved
PROVE PROPER OPERATION OF FATHOMETER DIGITAL READOUT.
Condition: Unknown
Due 11 January 1988
Resolved 11 January 1988
Electrical
Issued 11 January 1988 Resolved
MAKE PERMANENT INSTALLATION OF WIRING TO SALT WATER SANITARY PUMP PRESSURE SWITCH.
Condition: Unknown
Due 11 January 1988
Resolved 11 January 1988
Navigation
Issued 11 January 1988 Resolved
PROVE PROPER OPERATION OF STARBOARD SHAFT TACHOMETER AT ENGINEROOM AND BRIDGE STATIONS.
Condition: Unknown
Due 11 January 1988
Resolved 11 January 1988
Electrical
Issued 11 January 1988 Resolved
PROVE PROPER OPERATION OF NO. 1 AND NO. 2 SHIP'S SERVICE GENERATOR TACHOMETER.
Condition: Unknown
Due 11 January 1988
Resolved 11 January 1988
Electrical
Issued 11 January 1988 Resolved
PROVE PROPER OPERATION OF NO. 1 AND NO. 2 SHIP'S SERVICE GENERATOR OVERSPEED TRIP.
Condition: Unknown
Due 11 January 1988
Resolved 11 January 1988
Electrical
Issued 11 January 1988 Resolved
PROVE PROPER OPERATION OF SHIP'S SERVICE GENERATOR SWITCHBOARD FREQUENCY METER, NO. 2 AMP METER, AND NO. 2 VOLTAGE METER.
Condition: Unknown
Due 11 January 1988
Resolved 11 January 1988
Electrical
Issued 11 January 1988 Resolved
INSTALL FLAME SHIELD FOR NO. 1 SHIP'S SERVICE GENERATOR RACOR FUEL OIL FILTER/SEPARATOR.
Condition: Unknown
Due 11 January 1988
Resolved 11 January 1988
Electrical
Issued 11 January 1988 Resolved
INSTALL GLOBES AND GUARDS THROUGHOUT ENGINEERING SPACES.
Condition: Unknown
Due 11 January 1988
Resolved 11 January 1988
Fire Fighting
Issued 11 January 1988 Resolved
MAKE PERMANENT REPAIRS TO ELECTRICAL FIRE PUMP SUCTION PIPING AT STRAINER IN BILGE.
Condition: Unknown
Due 11 January 1988
Resolved 11 January 1988
Lifesaving
Issued 12 January 1987 Resolved
SUBMIT DOCUMENTATION THAT BOTH LIFERAFTS HAVE BEEN SERVICED BY A COAST GUARD APPROVED FACILITIY AND INSTALLED ON VESSEL NOT LATER THAN 31 MARCH 1987 TO [name withheld].
Condition: Unknown
Due 12 January 1987
Resolved 12 January 1987
Engineering
Issued 12 January 1987 Resolved
INSTALL AN AUDIBLE ALARM FOR THE ENGINE ROOM MACHINERY SAFETIES.
Condition: Unknown
Due 12 January 1987
Resolved 12 January 1987
Construction/Loadline
Issued 12 January 1987 Resolved
CROP OUT AND RENEW IN KIND BUCKED BULWARK STARBOARD SIDE 01 DECK IN WAY OF 2 STIFFERS OPPOSITE LADDER.
Condition: Unknown
Due 12 January 1987
Resolved 12 January 1987
Deck/Cargo
Issued 12 January 1987 Resolved
SUBMIT PLANS TO [name withheld] FOR THE INSTALLATION OF BULKTANK RELIEF TANK VALVES ON ALL 4 TANKS NLT 28FEB87 AND UPON APPROVAL YET NLT 30JUN87 INSTALL SAME AND DEMONSTRATE THE VALVES TO SATISFACTION OF COAST GUARD INSPECTOR.
Condition: Unknown
Due 12 January 1987
Resolved 12 January 1987

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.