MAURY USCG vessel records Sign in
← All vessels

BONITO II

BONITO II is a 1983 mobile offshore drilling unit. The Coast Guard has recorded 25 inspections since 1983, most recently in June 1996, along with 81 deficiencies.

Records from 1983 to 1996. Most recent: inspection, 21 June 1996.

Built
1983
Last inspected
21 June 1996
Documentation
No Operation - PM · documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

WTQ4119
Flag
UNITED STATES
—
Maury page id
psix-54787

Inspections, by type

…with no type recorded12
Years with a record 11 calendar years (1983–1996)
The 25 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

This record may be incomplete: the most recent inspection recorded for this vessel was 30 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Offshore class in Maury's sources begin in 1978.

Documentation record

Registered dimensions (L × B × D)180.0 ft × 175.0 ft × 24.3 ft
Registered tonnagegross 4,580 / net 4,580
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderINGALLS SHIPBUILDING DIV. · PASCAGOULA, MS, UNITED STATES · built 1983
Hull materialSteel
PropulsionNone
Hull shapeNot recorded
Hull configurationNot recorded
Hailing portPHILADELPHIA, PA
Trade endorsementsRegistry
DocumentationNo Operation - PM · issued 14 July 1989
Service, as the file records itMobile Offshore Drilling Unit
Hull formbarge (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it4580 - Regulatory (Subpart C or D), Gross Ton
4580 - Regulatory (Subpart C or D), Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 September 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.

Radio station licence

No FCC ship-station licence is recorded against this Official Number in the file of 6 September 2026. That is a fact about the licence file, not about the radio.

A report is not offered for this hull: Its record holds only 2 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. Reports.

Inspection history · 25

21 June 1996 Letter of Compliance (Initial/Renewal)
Administrative · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1357695
14 March 1996 Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 69886
16 October 1995 Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 112153
12 June 1995 Letter of Compliance (Initial/Renewal)
Administrative · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1371102
6 March 1995 Administrative
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 860168
6 February 1995 Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 643650
30 January 1995 Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 115545
17 November 1994 Type not recorded
No type recorded · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 1174628
9 June 1994 Letter of Compliance (Initial/Renewal)
Administrative · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 1467419
19 November 1990 Administrative
Administrative · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1297604
7 June 1990 Administrative
Administrative · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1214921
16 May 1990 Type not recorded
No type recorded · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1218352
1 March 1990 Hull Examination · Re-Inspection
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1231713
4 March 1989 COI Inspection
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1349987
25 October 1988 Administrative
Administrative · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1199770
28 April 1988 Type not recorded
No type recorded · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1350991
20 January 1988 Re-Inspection · Hull Examination
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1018018
28 May 1987 Deficiency Check
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1316157
4 April 1987 Drydock Extension · COI Inspection
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1012931
5 March 1986 Re-Inspection
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 996613
7 April 1985 Type not recorded
No type recorded · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1286193
23 February 1985 Type not recorded
No type recorded · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 978027
5 May 1984 Type not recorded
No type recorded · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1283208
28 February 1983 Type not recorded
No type recorded · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1279710
23 February 1983 Type not recorded
No type recorded · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1276319

Deficiency record · 81

Construction/Loadline
Issued 21 June 1996 Resolved
MAKE WATERTIGHT STUFFING TUBE FITTING ABOVE WATERTIGHT DOOR TO CO2 STORAGE ROOM.
Condition: Unknown
Due 21 July 1996
Resolved 18 May 2002
Resolution: MISLE Maintenance - Resolved all open deficiencies issued prior to 6/1/1997 where activity was closed and deficiency due date was past
Fire Fighting
Issued 21 June 1996 Resolved
REPLACE WASTED FIREMAIN PIPING ABOVE SHAKER HOUSE SERVICING FIRE STATION #15.
Condition: Unknown
Due 5 July 1996
Resolved 18 May 2002
Resolution: MISLE Maintenance - Resolved all open deficiencies issued prior to 6/1/1997 where activity was closed and deficiency due date was past
Electrical
Issued 21 June 1996 Resolved
REPAIR/REPLACE BROKEN SWITCH FOR SACKROOM VENTILATION FAN.
Condition: Unknown
Due 21 July 1996
Resolved 18 May 2002
Resolution: MISLE Maintenance - Resolved all open deficiencies issued prior to 6/1/1997 where activity was closed and deficiency due date was past
Electrical
Issued 21 June 1996 Resolved
PROVIDE SUPPORTS FOR JUNCTION BOXES IN SHAKER HOUSE.
Condition: Unknown
Due 21 July 1996
Resolved 18 May 2002
Resolution: MISLE Maintenance - Resolved all open deficiencies issued prior to 6/1/1997 where activity was closed and deficiency due date was past
Engineering
Issued 21 June 1996 Resolved
PERFORM ANNUAL HYDROSTATIC TESTING OF ALL FUEL OIL TRANSFER HOSES.
Condition: Unknown
Due 21 July 1996
Resolved 18 May 2002
Resolution: MISLE Maintenance - Resolved all open deficiencies issued prior to 6/1/1997 where activity was closed and deficiency due date was past
Electrical
Issued 21 June 1996 Resolved
SERVICE ALL BATTERIES ON TOP OF QUARTERS.
Condition: Unknown
Due 21 July 1996
Resolved 18 May 2002
Resolution: MISLE Maintenance - Resolved all open deficiencies issued prior to 6/1/1997 where activity was closed and deficiency due date was past
Fire Fighting
Issued 21 June 1996 Resolved
FREE UP ALL VENTILATION CLOSURES TO PAINT LOCKER.
Condition: Unknown
Due 21 July 1996
Resolved 18 May 2002
Resolution: MISLE Maintenance - Resolved all open deficiencies issued prior to 6/1/1997 where activity was closed and deficiency due date was past
Construction/Loadline
Issued 21 June 1996 Resolved
REPLACE BROKEN DOG & GASKET ON MAINDECK WATERTIGHT HATCH TO SACK ROOM.
Condition: Unknown
Due 21 July 1996
Resolved 18 May 2002
Resolution: MISLE Maintenance - Resolved all open deficiencies issued prior to 6/1/1997 where activity was closed and deficiency due date was past
Documentation
Issued 21 June 1996 Resolved
PROVIDE AN APPROVED CONSTRUCTION PORTFOLIO.
Condition: Unknown
Due 21 July 1996
Resolved 18 May 2002
Resolution: MISLE Maintenance - Resolved all open deficiencies issued prior to 6/1/1997 where activity was closed and deficiency due date was past
Accommodation/Occupational Safety
Issued 21 June 1996 Resolved
REPLACE WASTED HANDRAIL BY LIFERAFT #3.
Condition: Unknown
Due 21 July 1996
Resolved 18 May 2002
Resolution: MISLE Maintenance - Resolved all open deficiencies issued prior to 6/1/1997 where activity was closed and deficiency due date was past
Lifesaving
Issued 21 June 1996 Resolved
PROVIDE OPERATING INSTRUCTIONS FOR BOTH LIFERAFT DAVITS.
Condition: Unknown
Due 21 July 1996
Resolved 18 May 2002
Resolution: MISLE Maintenance - Resolved all open deficiencies issued prior to 6/1/1997 where activity was closed and deficiency due date was past
Lifesaving
Issued 21 June 1996 Resolved
PERFORM ANNUAL PROOF LOAD TEST ON BOTH LIFERAFT DAVIT HOOKS.
Condition: Unknown
Due 21 July 1996
Resolved 18 May 2002
Resolution: MISLE Maintenance - Resolved all open deficiencies issued prior to 6/1/1997 where activity was closed and deficiency due date was past
Electrical
Issued 21 June 1996 Resolved
INSTALL A BATTERY POWERED EMERGENCY LIGHT IN CHANGE ROOM ON 1ST LEVEL OF QUARTERS.
Condition: Unknown
Due 21 July 1996
Resolved 18 May 2002
Resolution: MISLE Maintenance - Resolved all open deficiencies issued prior to 6/1/1997 where activity was closed and deficiency due date was past
Electrical
Issued 21 June 1996 Resolved
PLACE ON EMERGENCY BUS CIRCUIT 1 OVERHEAD LIGHT IN 1ST LEVEL PORTSIDE _x001C_ QUARTERS TOILET & SHOWER ROOM.
Condition: Unknown
Due 21 July 1996
Resolved 18 May 2002
Resolution: MISLE Maintenance - Resolved all open deficiencies issued prior to 6/1/1997 where activity was closed and deficiency due date was past
Documentation
Issued 21 June 1996 Resolved
PROVIDE A COAST GUARD APPROVED EMERGENCY EVACUATION PLAN.
Condition: Unknown
Due 21 July 1996
Resolved 18 May 2002
Resolution: MISLE Maintenance - Resolved all open deficiencies issued prior to 6/1/1997 where activity was closed and deficiency due date was past
Deck/Cargo
Issued 21 June 1996 Resolved
PERFORM ANNUAL PROOF LOAD TEST & QUADRENNIAL PROOF LOAD TEST ON ALL CRANES.
Condition: Unknown
Due 21 July 1996
Resolved 18 May 2002
Resolution: MISLE Maintenance - Resolved all open deficiencies issued prior to 6/1/1997 where activity was closed and deficiency due date was past
Fire Fighting
Issued 21 June 1996 Resolved
PROVE PROPER OPERATION OF FIRE DAMPENER FOR REPLENISHMENT AIR ON 2ND LEVEL OF QUARTERS PORTSIDE.
Condition: Unknown
Due 21 July 1996
Resolved 18 May 2002
Resolution: MISLE Maintenance - Resolved all open deficiencies issued prior to 6/1/1997 where activity was closed and deficiency due date was past
Lifesaving
Issued 21 June 1996 Resolved
REPAIR/REPLACE FORWARD LIMIT SWITCH TO LIFEBOAT #2.
Condition: Unknown
Due 21 July 1996
Resolved 18 May 2002
Resolution: MISLE Maintenance - Resolved all open deficiencies issued prior to 6/1/1997 where activity was closed and deficiency due date was past
Navigation
Issued 21 June 1996 Resolved
PROVE PROPER OPERATION OF FOGHORN.
Condition: Unknown
Due 21 July 1996
Resolved 18 May 2002
Resolution: MISLE Maintenance - Resolved all open deficiencies issued prior to 6/1/1997 where activity was closed and deficiency due date was past
Fire Fighting
Issued 21 June 1996 Resolved
PROVIDE PANTS FOR ALL FIREMAN'S OUTFITS.
Condition: Unknown
Due 5 July 1996
Resolved 18 May 2002
Resolution: MISLE Maintenance - Resolved all open deficiencies issued prior to 6/1/1997 where activity was closed and deficiency due date was past
Electrical
Issued 21 June 1996 Resolved
REPAIR/REPLACE OVERSPEED DEVICE ON EMERGENCY GENERATOR.
Condition: Unknown
Due 21 July 1996
Resolved 18 May 2002
Resolution: MISLE Maintenance - Resolved all open deficiencies issued prior to 6/1/1997 where activity was closed and deficiency due date was past
Accommodation/Occupational Safety
Issued 21 June 1996 Resolved
REPAIR/REPLACE AUTOMATIC DOOR CLOSURES ON 1ST & 3RD LEVELS OF QUARTERS STAIR WELL.
Condition: Unknown
Due 21 July 1996
Resolved 18 May 2002
Resolution: MISLE Maintenance - Resolved all open deficiencies issued prior to 6/1/1997 where activity was closed and deficiency due date was past
Electrical
Issued 21 June 1996 Resolved
REPAIR TOTAL RIG SHUTDOWN SO THAT #2 & #3 GENERATORS ALSO SHUTDOWN.
Condition: Unknown
Due 21 July 1996
Resolved 18 May 2002
Resolution: MISLE Maintenance - Resolved all open deficiencies issued prior to 6/1/1997 where activity was closed and deficiency due date was past
Electrical
Issued 21 June 1996 Resolved
REPAIR/REPLACE CONTROL SWITCH FOR ENGINEROOM SUPPLY & EXHAUST FANS.
Condition: Unknown
Due 21 July 1996
Resolved 18 May 2002
Resolution: MISLE Maintenance - Resolved all open deficiencies issued prior to 6/1/1997 where activity was closed and deficiency due date was past
Electrical
Issued 21 June 1996 Resolved
PROVIDE MANUFACTURER'S DATA PLATE ON #2 GENERATOR SET.
Condition: Unknown
Due 21 July 1996
Resolved 18 May 2002
Resolution: MISLE Maintenance - Resolved all open deficiencies issued prior to 6/1/1997 where activity was closed and deficiency due date was past
Electrical
Issued 21 June 1996 Resolved
PROVIDE BLANKS OR BREAKERS FOR CIRCUIT BREAKER PANEL IN SCR ROOM.
Condition: Unknown
Due 21 July 1996
Resolved 18 May 2002
Resolution: MISLE Maintenance - Resolved all open deficiencies issued prior to 6/1/1997 where activity was closed and deficiency due date was past
Electrical
Issued 21 June 1996 Resolved
REPAIR/REPLACE EMERGENCY LIGHT BETWEEN #2 & #3 GENERATORS.
Condition: Unknown
Due 21 July 1996
Resolved 18 May 2002
Resolution: MISLE Maintenance - Resolved all open deficiencies issued prior to 6/1/1997 where activity was closed and deficiency due date was past
Deck/Cargo
Issued 21 June 1996 Resolved
TEST SAFETY RELIEF VALVES ON FOLLOWING AIR RECEIVERS: COLD START, RIG AIR, & DRILL FLOOR.
Condition: Unknown
Due 21 July 1996
Resolved 18 May 2002
Resolution: MISLE Maintenance - Resolved all open deficiencies issued prior to 6/1/1997 where activity was closed and deficiency due date was past
Deck/Cargo
Issued 21 June 1996 Resolved
PROVIDE SAFETY RELIEF VALVE OR REMOVE STOP VALVE AT BULK TANK COMPRESSOR.
Condition: Unknown
Due 21 July 1996
Resolved 18 May 2002
Resolution: MISLE Maintenance - Resolved all open deficiencies issued prior to 6/1/1997 where activity was closed and deficiency due date was past
Documentation
Issued 12 June 1995 Resolved
Provide on board an approved Shipboard Oil Pollution Emergency Plan as required by regulation 26 of MARPOL.
Condition: Unknown
Due 12 June 1995
Resolved 12 June 1995
Lifesaving
Issued 16 May 1990 Resolved
PROVIDE ONE ADDITIONAL 25 PERSON DAVIT LAUNCED INFLATABLE LIFERAFT WITH CURRENT SERVICE DATE (VESSEL TOTAL CAPACITY 100 PERSON). VESSEL LIMITED TO 75 PERSON TOTAL UNTIL COMPLETED. ADVISE [name withheld] RAFT IS INSTALLED.
Condition: Unknown
Due 16 May 1990
Resolved 16 May 1990
Lifesaving
Issued 1 March 1990 Resolved
RENEW STBD LIFEBOAT EMBARKATION FLOODLIGHT LENSE COVER.
Condition: Unknown
Due 1 March 1990
Resolved 1 March 1990
Electrical
Issued 1 March 1990 Resolved
REPAIR AND PROVE OPERATION OF ENGINE ALARM PANEL INDICATORS FOR ENGINE #1 AND 2 OVERSPEED TRIPS.
Condition: Unknown
Due 1 March 1990
Resolved 1 March 1990
Lifesaving
Issued 1 March 1990 Resolved
PROVIDE TWO ROW OARS, ONE STEERING OAR AND ONE BOAT HOOK FOR PORT LIFEBOAT.
Condition: Unknown
Due 1 March 1990
Resolved 1 March 1990
Navigation
Issued 1 March 1990 Resolved
REPAIR AND PROVE OPERATION OF PORT OBSTRUCTION LIGHT.
Condition: Unknown
Due 1 March 1990
Resolved 1 March 1990
Electrical
Issued 1 March 1990 Resolved
INSTALL METALLIC CABLE STRAPS FOR CABLE SUPPORT IN SHALE SHAKER AREA AND DRILL FLOOR.
Condition: Unknown
Due 1 March 1990
Resolved 1 March 1990
Electrical
Issued 1 March 1990 Resolved
REPAIR AND PROVE OPERATION OF EMERGENCY GENERATOR LOW LUBE OIL TRIP INDICATOR.
Condition: Unknown
Due 1 March 1990
Resolved 1 March 1990
Electrical
Issued 1 March 1990 Resolved
REPAIR AND PROVE OPERATION ENGINE ROOM EMERGENCY BATTERY POWERED LIGHT IN WAY OF EXIT TO SACK ROOM.
Condition: Unknown
Due 1 March 1990
Resolved 1 March 1990
Accommodation/Occupational Safety
Issued 1 March 1990 Resolved
REPAIR THE INSTALLED COMBUSTIBLE GAS DETECTION SYSTEM SENSORS IN THE FOLLOWING ZONES: #1 & 4 (OLD SYSTEM) & #2 & 8 (NEW SYSTEM). PROVE OPERATIONOF SENSORS AND REPORT SAME TO [name withheld].
Condition: Unknown
Due 1 March 1990
Resolved 1 March 1990
Accommodation/Occupational Safety
Issued 1 March 1990 Resolved
REPAIR AND PROVE OPERATIONS OF INSTALLED H2S DETECTION SYSTEM SENSORS IN THE FOLLOWING ZONES: # 4, 7, 8 & 15.
Condition: Unknown
Due 1 March 1990
Resolved 1 March 1990
Lifesaving
Issued 1 March 1990 Resolved
PROVIDE TWO ADDITIONAL (4 TOTAL) 25 PERSON DAVIT LAUNCHED INFLATABLE LIFE- RAFTS, WHICH ARE WITHIN SERVICE DATES. VESSEL LIMITED TO 69 TOTAL PERSONS UNTIL COMPLETED. ADVISE [name withheld] AS TO CHANGES IN NUMBER OF LIFERAFTS ON BOARD.
Condition: Unknown
Due 1 March 1990
Resolved 1 March 1990
Lifesaving
Issued 1 March 1990 Resolved
RENEW ALL FOUR LINE THROWING APPARATUS ROCKETS (2 BUOYANT & 2 NON-BUOYANT).
Condition: Unknown
Due 1 March 1990
Resolved 1 March 1990
Fire Fighting
Issued 1 March 1990 Resolved
PROVIDE COPY OF FOAM SAMPLE ANALYSIS.
Condition: Unknown
Due 1 March 1990
Resolved 1 March 1990
Fire Fighting
Issued 1 March 1990 Resolved
REINSTALL THE MISSING (#20) FIXED DRY CHEMICAL FIRE EXTINGUISHER FOR THE INBOARD GALLEY GRILL. THIS GRILL IS NOT TO BE UTILIZED FOR COOKING UNTIL COMPLETED.
Condition: Unknown
Due 1 March 1990
Resolved 1 March 1990
Construction/Loadline
Issued 1 March 1990 Resolved
PROVIDE COPY OF FINAL DIVE REPORT INCLUDING VIDEO TAPE OF UNDERWATER SURVEYAND WRITTEN REPORT OF N.D.T.
Condition: Unknown
Due 1 March 1990
Resolved 1 March 1990
Documentation
Issued 4 March 1989 Resolved
PROVIDE A COPY OF THE USCG APPROVED UPDATED OPERATING MANUAL PER 46 CFR 109.121(C), THE REQUIREMENTS OF WHICH BECAME EFFECTIVE 1 JULY 1989.
Condition: Unknown
Due 4 March 1989
Resolved 4 March 1989
Navigation
Issued 4 March 1989 Resolved
DEMONSTRATE PROPER OPERATION OF THE STARBOARD OBSTRUCTION LIGHT.
Condition: Unknown
Due 4 March 1989
Resolved 4 March 1989
Construction/Loadline
Issued 4 March 1989 Resolved
REPAINT 16 INCH, PERIMETER STRIPE, AIMING CIRCLES ON THE HELO-DECK.
Condition: Unknown
Due 4 March 1989
Resolved 4 March 1989
Unknown
Issued 4 March 1989 Resolved
REPLACE AND DEMONSTRATE SATISFACTORY OPERATION OF RELIEF VALVE FOR DRILL FLOOR AIR RECEIVER. VALVE IS TO BE ASME APPROVED AND SET FOR LESS THAN 200 PSI.
Condition: Unknown
Due 4 March 1989
Resolved 4 March 1989
Lifesaving
Issued 4 March 1989 Resolved
PROVIDE ONE SERVICED 25 PERSON LIFERAFT TO REPLACE AN OUTDATED LIFERAFT, SER. NO. 25MMUS 12/32.
Condition: Unknown
Due 4 March 1989
Resolved 4 March 1989
Electrical
Issued 4 March 1989 Resolved
INSTALL A FLASHING RED GENERAL ALARM LIGHT IN THE MUD PIT ROOM. ELECTRICALINSTALLATION TO BE EXPLOSION-PROOF AND BE OF UL APPROVED EQUIPMENT. THIS SYSTEM MUST BE SUPPLIED FROM THE EMERGENCY SOURCE OF POWER THROUGH A RELAY THAT IS OPERATED BY THE GENERAL ALARM SYSTEM.
Condition: Unknown
Due 4 March 1989
Resolved 4 March 1989
Documentation
Issued 4 March 1989 Resolved
PROVIDE A COPY OF VESSEL'S DOCUMENTATION CERTIFICATE TO USCG MARINE SAFETY OFFICE HONOLULU, HAWAII.
Condition: Unknown
Due 4 March 1989
Resolved 4 March 1989
Unknown
Issued 4 March 1989 Resolved
DEMONSTRATE PROPER CALIBRATION OF H2S AND COMBUSTIBLE GAS DETECTION SYSTEMS.
Condition: Unknown
Due 4 March 1989
Resolved 4 March 1989
Electrical
Issued 4 March 1989 Resolved
INSTALL END BELL AND DEMONSTRATE SATISFACTORY OVERSPEED, REVERSE POWER, ANDLOW LUBE OIL ALARMS AND TRIPS FOR THE #3 DIESEL GENERATOR.
Condition: Unknown
Due 4 March 1989
Resolved 4 March 1989
Lifesaving
Issued 20 January 1988 Resolved
PROVIDE 2 USCG APPROVED SMOKE DISTRESS SIGNALS FOR LIFEBOAT #1.
Condition: Unknown
Due 20 January 1988
Resolved 20 January 1988
Lifesaving
Issued 20 January 1988 Resolved
PROVIDE 2 USCG APPROVED SMOKE DISTRESS SIGNALS AND 12 USCG APPROVED PARACHUTE DISTRESS FLARES FOR LIFEBOAT #2.
Condition: Unknown
Due 20 January 1988
Resolved 20 January 1988
Lifesaving
Issued 20 January 1988 Resolved
SERVICE THE 25 PERSON LIFERAFT FOR STATION #3.
Condition: Unknown
Due 20 January 1988
Resolved 20 January 1988
Lifesaving
Issued 20 January 1988 Resolved
PROVIDE A USCG APPROVED SMOKE SIGNAL FOR THE RING BUOY LOCATED ABOVE THE DRILL FLOOR SHED.
Condition: Unknown
Due 20 January 1988
Resolved 20 January 1988
Construction/Loadline
Issued 20 January 1988 Resolved
CONDUCT AN UNDERWATER EXAMINATION OF ALL 3 SPUD CANS IN THE PRESENCE OF A COAST GUARD INSPECTOR, UTILIZING AN ADEQUATE COLOR VIDEO SYSTEM AND RECORDER.
Condition: Unknown
Due 20 January 1988
Resolved 20 January 1988
Fire Fighting
Issued 20 January 1988 Resolved
PROVIDE A 3 CELL EXPLOSION PROOF FLASHLIGHT FOR BOTH FIREMAN'S OUTFITS.
Condition: Unknown
Due 20 January 1988
Resolved 20 January 1988
Construction/Loadline
Issued 20 January 1988 Resolved
PROVE PROPER OPERATION OF THE OILY WATER SEPARATOR AND BILGE MONITOR; PROVIDE A COPY OF THE USCG TYPE APPROVAL FOR THE UNIT.
Condition: Unknown
Due 20 January 1988
Resolved 20 January 1988
Documentation
Issued 20 January 1988 Resolved
PROVIDE AND POST THE STABILITY LETTER DATED 30AUG83 AS REFERENCED ON THE CERTIFICATE OF INSPECTION. ALSO PROVIDE THE USCG APPROVED OPERATING MANUALWHICH IS REFERENCED IN THE 30AUG83 STABILITY LETTER.
Condition: Unknown
Due 20 January 1988
Resolved 20 January 1988
Lifesaving
Issued 20 January 1988 Resolved
THE TOTAL NUMBER OF PERSONS ALLOWED ONBOARD THE RIG IS REDUCED TO 75 WHENEVER 1 OF THE 25 PERSON LIFERAFTS IS OFF THE RIG FOR ANNUAL SERVICING.
Condition: Unknown
Due 20 January 1988
Resolved 20 January 1988
Lifesaving
Issued 28 May 1987 Resolved
THE TOTAL NUMBER OF PERSONS ALLOWED IS REDUCED TO (69) WHEN (1) OF THE 25 PERSON INFLATABLE LIFERAFTS IS OFF THE RIG FOR SERVICING.
Condition: Unknown
Due 28 May 1987
Resolved 28 May 1987
Deck/Cargo
Issued 4 April 1987 Resolved
CONDUCT INTERNAL EXAMINATION OR HYDROSTATIC TEST OF THE RIG FLOOR AIR RECEIVER AND DEMONSTRATE THE ASSOCIATED RELIEF VALVE.
Condition: Unknown
Due 4 April 1987
Resolved 4 April 1987
Unknown
Issued 4 April 1987 Resolved
MAKE AVAILABLE FOR INTERNAL INSPECTION BY A COAST GUARD INSPECTOR, DRY BULK"P" TANKS NUMBER 1,2, & 3 AND BARITE TANKS NUMBER 1 & 3.
Condition: Unknown
Due 4 April 1987
Resolved 4 April 1987
Lifesaving
Issued 4 April 1987 Resolved
CONDUCT ANNUAL SERVICING OF INFLATABLE LIFERAFTS; SERIAL NUMBERED MMUS5 ANDMMUS6.
Condition: Unknown
Due 4 April 1987
Resolved 4 April 1987
Electrical
Issued 23 February 1985 Resolved
REPAIR PA/INTERCOM STATION IN PORT CRANE CAB.
Condition: Unknown
Due 23 February 1985
Resolved 23 February 1985
Construction/Loadline
Issued 23 February 1985 Resolved
REPOSITION MAIN SEA VALVE SO THAT IT IS ACCESSIBLE TO BE OPENED FOR INSPECTION.
Condition: Unknown
Due 23 February 1985
Resolved 23 February 1985
Construction/Loadline
Issued 23 February 1985 Resolved
EFFECT PERMANENT REPAIRS TO DAMAGE OF HULL IN WAY OF DRILL WATER TANK #4 PORT SIDE AFT AT TURN OF BILGE AND SIDESHELL INCLUDING HULL PLATING, ALL SIDE FRAMES AND LONGITUDINALS.
Condition: Unknown
Due 23 February 1985
Resolved 23 February 1985
Lifesaving
Issued 23 February 1985 Resolved
REPLACE EXISTING TEMPORARY L/R #1 WITH A DAVIT LAUNCHED L/R.
Condition: Unknown
Due 23 February 1985
Resolved 23 February 1985
Navigation
Issued 23 February 1985 Resolved
REPAIR OBSTRUCTION LIGHTS/FLASHING UNIT SO AS TO FLASH MORSE "V".
Condition: Unknown
Due 23 February 1985
Resolved 23 February 1985
Lifesaving
Issued 23 February 1985 Resolved
PROVIDE TWO ADDITIONAL EMBARKATION LADDERS FOR #1 & #2 LIFEBOATS.
Condition: Unknown
Due 23 February 1985
Resolved 23 February 1985
Electrical
Issued 23 February 1985 Resolved
REPAIR/RESET #3 GENERATOR OVERSPEED TRIP TO SHUTDOWN AT 1380 RPM.
Condition: Unknown
Due 23 February 1985
Resolved 23 February 1985
Deck/Cargo
Issued 23 February 1985 Resolved
REPAIR DIESEL OIL TRANSFER EMERGENCY SHUTDOWN SYSTEM. PRESENTLY NONE OF THE ACTIVATION BUTTONS ARE OPERABLE.
Condition: Unknown
Due 23 February 1985
Resolved 23 February 1985
Accommodation/Occupational Safety
Issued 23 February 1985 Resolved
PROVIDE EXPLOSION PROOF ALARM/ROTATING BEACONS IN MUD PIT AND MUD PUMP ROOMS SIGNALING LOSS OF VENTILATION IN SAME.
Condition: Unknown
Due 23 February 1985
Resolved 23 February 1985
Accommodation/Occupational Safety
Issued 23 February 1985 Resolved
PROVIDE RAILING ON MAIN DECK, STERN, BENEATH DRILL FLOOR.
Condition: Unknown
Due 23 February 1985
Resolved 23 February 1985
Deck/Cargo
Issued 5 May 1984 Resolved
PROVIDE AN APPROVED COPY OF THE VESSEL'S OPERATING MANUAL.
Condition: Unknown
Due 5 May 1984
Resolved 5 May 1984
Documentation
Issued 28 February 1983 Resolved
SUBMIT TO [name withheld] DISTRICT (MMT), THE RESULTS AND NECESSARY SUPPORTING DATA TO PROVE SISTER UNIT STABILITY AS PER 46 CFR 108
Condition: Unknown
Due 28 February 1983
Resolved 28 February 1983
Documentation
Issued 28 February 1983 Resolved
CONDUCTED ON MODU GLOMAR MAIN PASS I(O.N. 647709, INGALLS HULL 6401) ON 02 MAY 1982 TEMP. STABILITY LTTR EXPIRES ON 18 JUNE 1983.
Condition: Unknown
Due 28 February 1983
Resolved 28 February 1983
Unknown
Issued 28 February 1983 Resolved
NEW INSTALLATIONS CHANGES OR MODIFICATIONS TO PLANS ARE REQUIRED TO BE SUBMITTED FOR APPROVAL.
Condition: Unknown
Due 28 February 1983
Resolved 28 February 1983

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.