← All vessels
SITEAM MARS
SITEAM MARS is a 1982 tank ship. The Coast Guard has recorded 75 inspections since 1984, most recently in May 2006, along with 43 deficiencies and 4 operational controls.
Records from 1984 to 2006. Most recent: inspection, 17 May 2006.
- Built
- 1982
- Last inspected
- 17 May 2006
- Documentation
- Not in the documentation file of 10 September 2026
- Deficiencies
- 43 recorded · 0 without a recorded resolution
- Controls
- None recorded without a removal date
Identity
7926253 View on MarineTraffic leaves Maury; a third-party site, nothing from it is stored here
V7FL4
54793
Flag
MARSHALL ISLANDS
—
Maury page id
psix-54793
Inspections, by type
…with no type recorded49
Years with a record
23 calendar years (1984–2006)
The 75 inspections in the strip above, split by the kind of activity the US
Coast Guard recorded. Years with a record are calendar years in which a record exists, not
years in service. What Maury does not do.
This record may be incomplete: the most recent inspection recorded for this vessel was 20 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Tank Ship class in Maury's sources begin in 1980.
Documentation record
Tonnage as PSIX records it24330 - Regulatory (Subpart C or D), Gross Ton
24330 - Convention (Subpart B), Gross Ton
13501 - Regulatory (Subpart C or D), Net Ton
13501 - Convention (Subpart B), Net Ton
42010 - Dead Weight, Ton
52044 - Displacement, Ton
24330 - Convention (Subpart B), Gross Ton
13501 - Regulatory (Subpart C or D), Net Ton
13501 - Convention (Subpart B), Net Ton
42010 - Dead Weight, Ton
52044 - Displacement, Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.
Radio station licence
No FCC ship-station licence is recorded against this Official Number in the file of
6 September 2026. That is a fact about the licence file, not about the radio.
Inspection history · 75
17 May 2006
Type not recorded
No type recorded · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 2651759
13 February 2006
ISPS II Exam · MARPOL Annex V Examination · Ballast Water Examination · MARPOL Annex I Examination · COC-CHEM Annual · MARPOL Annex II Examination
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 2583834
28 February 2005
Type not recorded
No type recorded · MSO PORTLAND MAINE · USCG Northeast District (CGD-NE) · Activity 2300949
31 January 2005
COC-CHEM Renew · ISPS III Exam · Ballast Water Examination
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 2282631
21 August 2004
Deficiency Check
Physical examination · Resident Inspection Office St. Croix · USCG Southeast District (CGD-SE) · Activity 2172074
13 August 2004
ISPS II Exam
Physical examination · Resident Inspection Office St. Croix · USCG Southeast District (CGD-SE) · Activity 2165000
25 February 2004
Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 2014452
25 February 2004
Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 2036021
18 February 2004
Certificate of Compliance · MARPOL Annex I Examination
Physical examination · Resident Inspection Office St. Croix · USCG Southeast District (CGD-SE) · Activity 2007170
12 February 2003
Security Inspection
Physical examination · Marine Safety Unit Victoria · USCG Heartland District (CGD-H) · Activity 1743817
27 January 2003
Certificate of Compliance
Administrative · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 1736077
3 January 2003
Type not recorded
No type recorded · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1762795
9 May 2002
Deficiency Check
Physical examination · MSO SAVANNAH · USCG Southeast District (CGD-SE) · Activity 1614734
8 May 2002
Administrative Inspection
Administrative · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 1614599
8 January 2002
Annual Inspection
Physical examination · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 1477626
31 January 2001
Type not recorded
No type recorded · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 286606
31 January 2001
Letter of Compliance (Initial/Renewal)
Administrative · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 1057595
26 February 2000
Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 275276
19 January 1999
Type not recorded
No type recorded · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 424529
19 January 1999
Letter of Compliance (Initial/Renewal)
Administrative · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 1029371
21 December 1998
Type not recorded
No type recorded · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 129333
27 July 1998
Type not recorded
No type recorded · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 418363
22 January 1998
Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 411973
3 November 1997
Type not recorded
No type recorded · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 444553
27 June 1997
Type not recorded
No type recorded · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 405024
30 January 1997
Type not recorded
No type recorded · MSO SAVANNAH · USCG Southeast District (CGD-SE) · Activity 399987
30 January 1997
Letter of Compliance (Initial/Renewal)
Administrative · MSO SAVANNAH · USCG Southeast District (CGD-SE) · Activity 1101241
7 October 1996
Type not recorded
No type recorded · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 396138
25 December 1995
Type not recorded
No type recorded · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 386244
25 December 1995
Letter of Compliance (Initial/Renewal)
Administrative · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 875456
11 September 1995
Type not recorded
No type recorded · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 198413
11 September 1995
Type not recorded
No type recorded · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 756841
30 November 1994
Deficiency Check
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1179209
28 November 1994
Type not recorded
No type recorded · MSD CONCORD · USCG Southwest District (CGD-SW) · Activity 372656
28 November 1994
Type not recorded
No type recorded · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 865622
16 August 1994
Type not recorded
No type recorded · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 369573
28 March 1994
Deficiency Check
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1432782
6 March 1994
Type not recorded
No type recorded · MSO WILMINGTON · USCG East District (CGD-E) · Activity 364935
25 February 1994
Type not recorded
No type recorded · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 1165651
19 February 1994
Type not recorded
No type recorded · COTP LONG ISLAND SOUND · USCG Northeast District (CGD-NE) · Activity 478558
12 February 1994
Deficiency Check
Physical examination · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 1164785
29 September 1993
Certificate of Compliance
Administrative · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 841908
5 December 1992
Type not recorded
No type recorded · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 354836
5 December 1992
Certificate of Compliance
Administrative · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 1387299
5 December 1991
Type not recorded
No type recorded · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 647839
21 November 1991
Type not recorded
No type recorded · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 472122
21 November 1991
Certificate of Compliance
Administrative · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 1387238
18 January 1991
Certificate of Compliance
Administrative · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 1225311
25 September 1990
Type not recorded
No type recorded · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 474860
8 May 1990
Type not recorded
No type recorded · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 336990
8 May 1990
Deficiency Check
Physical examination · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 912825
3 May 1990
Administrative
Administrative · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1211028
15 February 1990
Type not recorded
No type recorded · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 445015
4 February 1990
Deficiency Check
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 980076
3 February 1990
Type not recorded
No type recorded · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 475787
15 September 1989
Certificate of Compliance
Administrative · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1195873
1 July 1989
Type not recorded
No type recorded · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 437674
24 June 1989
Type not recorded
No type recorded · COTP NEW YORK · USCG Northeast District (CGD-NE) · Activity 331027
6 April 1989
Type not recorded
No type recorded · COTP NEW YORK · USCG Northeast District (CGD-NE) · Activity 524347
23 August 1988
Type not recorded
No type recorded · COTP HOUSTON · USCG Heartland District (CGD-H) · Activity 463594
23 August 1988
Type not recorded
No type recorded · MIO HOUSTON · USCG Heartland District (CGD-H) · Activity 1039248
1 June 1988
Type not recorded
No type recorded · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 442683
26 August 1987
Certificate of Compliance · MARPOL Annex II Examination
Physical examination · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1030633
21 August 1987
Type not recorded
No type recorded · THE UNKNOWN UNIT · Activity 1338267
7 July 1987
Type not recorded
No type recorded · COTP NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 317125
11 February 1987
Type not recorded
No type recorded · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 314548
21 January 1987
Type not recorded
No type recorded · COTP HOUSTON · USCG Heartland District (CGD-H) · Activity 313832
28 August 1986
Type not recorded
No type recorded · COTP NEW YORK · USCG Northeast District (CGD-NE) · Activity 311120
28 August 1986
Type not recorded
No type recorded · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1335991
27 July 1986
Type not recorded
No type recorded · COTP NEW HAVEN · USCG Northeast District (CGD-NE) · Activity 534209
27 February 1986
Type not recorded
No type recorded · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 466522
31 July 1985
Type not recorded
No type recorded · COTP NEW HAVEN · USCG Northeast District (CGD-NE) · Activity 453526
31 July 1985
Type not recorded
No type recorded · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1298222
12 March 1985
Type not recorded
No type recorded · COTP NEW HAVEN · USCG Northeast District (CGD-NE) · Activity 436857
3 December 1984
Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 976209
Deficiency record · 43
Deck/Cargo › Cargo Stowage › General
Issued 18 February 2004
Resolved
Make permanent repairs to the three conduit junction boxes near amidships of the vessel. They are fractured and not considered safe for atmosphere. LEGACY COMPONENT DESC: Electrical Conduit Boxes
Engineering › Freshwater System (air cooling) › Hose
Issued 18 February 2004
Resolved
Make permanent repairs to the discharge line of the #2 air cooler for the main diesel engine.
Pollution Prevention/Response › Prevention Equipment › Oily Mixture Discharge Fixed Piping System
Issued 18 February 2004
Resolved
Make permanent repairs to the ODME line forward on the 2 deck in pump room. Has a pin hole leak. LEGACY COMPONENT DESC: Oily Mixture Discharge Fixed Piping System
Pollution Prevention/Response › Prevention Equipment › Cargo Monitor/Control System
Issued 18 February 2004
Resolved
Prove proper operation of ODME to the satisfaction of class and prior to departure.
Deck/Cargo › Holds/Tanks › Hatch
Issued 18 February 2004
Resolved
Make permanent repairs to the A60 boundary up forward of the Power Pack Room. The stuffing compound needs to be renewed. To the satisfaction of class and prior to depart of port.
Engineering › Freshwater Generation System › Piping
Issued 18 February 2004
Resolved
Make permanent repairs to the piping in the main space. Upper catwalk on the centerline port side.
Deck/Cargo › Inert Gas System
Issued 8 January 2002
Resolved
IGS SYSTEM WAS UNABLE TO MAINTAIN PROPER OXYGEN LEVELS AND REGULATE HIGH PRESSURE IN SERVICE LINES. REPAIR TO SATISFACTION OF CALSS. SOLAS 74 AMEND II-2 REG 62 LEGACY COMPONENT DESC: PURGE VALVE
Pollution Prevention/Response › Prevention Equipment
Issued 8 January 2002
Resolved
FOUND VARIOUS SOFT PATCHES AND THE SEWAGE PUMP WA FOUND LEAKING SEWAGE ON THE DECK INSIDE A CONTAINMENT. REPAIR TO SATISFACTION OF CLASS. MARPOL 73/78 ANNEX IV. A CONDITION OF CLASS WAS ISSUED. LEGACY COMPONENT DESC: Marine Sanitation Device, Type II
Deck/Cargo › Holds/Tanks
Issued 8 January 2002
Resolved
HIGH AND OVERFILL ALARMS FOR VARIOUS CARGO TANKS, WERE NOT OPERATING PROPERLY AT THE 98% SETTING. REPAIR TO SATISFACTION OF CLASS. 46cfr39.30.1 LEGACY COMPONENT DESC: Tank Level Monitoring Device
Lifesaving
Issued 31 January 2001
Resolved
Insufficiant amount of rations in the Port/Stbd lifeboats IAW SOLAS 74 III/11 (xii). Provide invoice.
Deck/Cargo
Issued 31 January 2001
Resolved
Unable to test high level and overfill alarms IAW BCH 4.14. Prove proper operation to the satisfaction of the attending USCG Marine Inspector or provide written procedures as to how to ensure a level of safety when discharging cargo and not overfilling any other tank.
Lifesaving
Issued 31 January 2001
Resolved
Broken lifeline beckets on port/stbd lifeboats IAW SOLAS 74 III/11 (viii). Repair to the satisfaction of the attending USCG Marine Inspector.
Deck/Cargo
Issued 31 January 2001
Resolved
High level and overfill alarms are not marked IAW 33 CFR 155.480 and 46 CFR39.20-7. Correct to the satisfaction of the attending USCG Marine Inspector.
Fire Fighting
Issued 19 January 1999
Resolved
MAKE PERMENANT REPAIRS TO #1 FIRE MAIN ON DISCHARGE SIDE AND SUCTION SIDE OF #1 FIRE PUMP IN WAY OF BILGE EDUCTOR TO THE SATISFACTION OF CLASS SOCIETY PRIOR TO NEXT U.S. ENTRY.
Engineering
Issued 21 December 1998
Resolved
Excessive and uneven wear on the cam shaft lobes. When the cams were shifted to reverse the engine, valve timing was altered enough to prevent ignition of fuel inside the cylinder.
Deck/Cargo
Issued 22 January 1998
Resolved
HIGH LEVEL ALARMS REQUIRED BY 46 CFR 153 TABLE 1 AND .409 FOR CARGOES ON THE VESSEL'S COF NOT INSTALLED. REQUIRED INSTALLATION PRIOR TO CARRYING THOSE CARGOES IN U.S. WATERS.
Deck/Cargo
Issued 25 December 1995
Resolved
PROVE PROPER OPERATION OF INERT GAS SYSTEM IAW 46 CFR 32.53-70 (b) (3), (4), (5) and 32.53-75 (b) TO ATTENDING USCG MARINE INSPECTOR OR CLASS SOCIETY TEST REPORT PRIOR TO NEXT U.S. PORT.
Deck/Cargo
Issued 28 November 1994
Resolved
Prior to departure from San Francisco Bay, Have vessel classification society visit the vessel and make recommendations for permanent repairs to leaking on deck steam piping near the Port side cargo manifolds. Provide afaxed copy of surveyor's report for clearance.
Lifesaving
Issued 28 November 1994
Resolved
Prior to departure from San Francisco Bay, demonstrate that the required amount of life preserver water lights are aboard.
Fire Fighting
Issued 28 November 1994
Resolved
Prior to departure from San Francisco Bay, have vessel's classification society visit vessel and make recommendations for repairs to leaking fire main piping near the starboard side of the No. 5 center cargo hatch. Provide a faxed copy of surveyors report for clearance.
Lifesaving
Issued 28 November 1994
Resolved
Prior to departure from San Francisco Bay, Demonstrate proper operation of the Port side aft ring buoy water light.
Deck/Cargo
Issued 25 February 1994
Resolved
PROVIDE A HIGH LEVEL ALARM THAT CAN BE SEEN AND HEARD ON THE MAIN DECK PER 46 CFR153.409, OR REMOVE THISE CARGOES FROM THE CERTIFICATE OF FITNESS REQUIRING SAME(NOT ASSOCIATED WITH VCS BUT NOTED).
Unknown
Issued 25 February 1994
Resolved
PROVIDE VAPOR PRESSURE DROP VS. TRANSFER RATE GRAPH/CHART INCLUDED WITH OILTRANSFER PROCEDURES.
Documentation
Issued 25 February 1994
Resolved
PROVIDE OIL TRANSFER PROCEDURES WITH A COMPLERTE VAPOR CONTROL SYSTEM DESCRIPTION IAW 33CFR155.750.
Unknown
Issued 25 February 1994
Resolved
PROVIDE VAPOR PRESSURE DROP CALCULATIONS FOR 50% AIR/VAPOR MIX AND VAPOR GROWTH RATE APPLICABLE FOR CARGO TRANSFERS REQUIRING VCS. IAW 46CFR39.30- 1(b)(2).
Unknown
Issued 25 February 1994
Resolved
PROVIDE VAPOR PRESSURE DROP CALCULATIONS FOR MAXIMUM AND LESSER TRANSFER RATES FROM THE MOST REMOTE CARGO TANK IAW 46CFR39.30-1(b)(1).
Documentation
Issued 29 September 1993
Resolved
PROVIDE COPIES OF RENEWED CLASS DEFICIENCIES.
Deck/Cargo
Issued 29 September 1993
Resolved
DEMONSTRATE PROPER OPERATIONAL TEST OF OIL CONTENT MONITOR, DEMONSTRATE PROPER ALARM FUNCTIONS, STARTING INTERLOCK AND AUTO STOP VALVE TO USCG AT NEXT U. S. PORT.
Lifesaving
Issued 29 September 1993
Resolved
MAKE PERMANENT REPAIRS TO LEAKS IN STEAM PIPES ON DECK PRIOR TO NEXT U. S. VOYAGE.
Electrical
Issued 29 September 1993
Resolved
DEMONSTRATE PROPER OPERATIONAL TEST OF AUTOMATIC START OF EMERGENCY GENERATOR.
Documentation
Issued 29 September 1993
Resolved
PROVIDE DNV CLASS REPORT FOR ARPA INSTALLATION AND GYRO COMPASS SERVICING.
Documentation
Issued 29 September 1993
Resolved
PROVIDE PORTABLE FIRE EXTINGUISHING REPORT.
Documentation
Issued 29 September 1993
Resolved
PROVIDE COPY OF SCBA SERVICE REPORT.
Documentation
Issued 29 September 1993
Resolved
PROVIDE COPY OF LIFERAFT SERVICING REPORT.
Documentation
Issued 29 September 1993
Resolved
PROVIDE SERVICING REPORT OF LEL AND TOXIC GAS INDICATORS AND PROVIDE PROPERCALIBRATING MEDIUMS.
Deck/Cargo
Issued 15 September 1989
Resolved
PROVIDE SUITABLE TOXIC GAS METERS PRIOR TO LOADING NEXT TOXIC CARGO.
Fire Fighting
Issued 15 September 1989
Resolved
PROVIDE FIRE FIGHTING FOAM THAT MEETS MANUFACTURER'S SPECIFICATIONS PRIOR TO LOADING NEXT FLAMMABLE CARGO.
Deck/Cargo
Issued 15 September 1989
Resolved
PROVE HYDROSTATIC TEST OF CARGO HOSES PRIOR TO NEXT USE.
Deck/Cargo
Issued 15 September 1989
Resolved
MAKE PERMANENT REPAIRS TO LEAKS IN CARGO STEAM HEATING LINES PRIOR TO LOADING TOXIC OR FLAMMABLE CARGOES.
Accommodation/Occupational Safety
Issued 15 September 1989
Resolved
MAKE PERMANENT AREPAIRS TO LEAK IN EYE WASH/SHOWER STATION FORWARD OF PORT SIDE TRANSFER MANIFOLD.
Deck/Cargo
Issued 11 February 1987
Resolved
VSL DID NOT HAVE TOXIC VAPOR DETECTOR TUBES FOR ETHYLENE DICHLORIDE A VIOLATION OF 46 CFR 153.526
Deck/Cargo
Issued 28 August 1986
Resolved
TOXIC VAPOR DECTECTORS FOR BENZENE AND ETHYLENE DICLORIDE NOT ON BOARD (46 CFR 153.526).
Deck/Cargo
Issued 28 August 1986
Resolved
THE WARNING SIGN REQUIRED BY 46 CFR 153.1060(C) WAS NOT DISPLAYED.
Ownership record
The Coast Guard's documentation record for this hull -- the Abstract of Title,
with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National
Vessel Documentation Center, files it here with its date, and every reader of this page gets it.