M/V CUTTYHUNK

M/V CUTTYHUNK is a 1983 passenger vessel (inspected). The Coast Guard has recorded 22 inspections since 2016, most recently in March 2026, along with 39 deficiencies.

Records from 2016 to 2026. Most recent: inspection, 10 March 2026.

Built
1983
Last inspected
10 March 2026
Documentation
Expired · documentation file of 10 August 2026
Controls
None recorded without a removal date

Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 2016.

Inspection record

Last inspected 10 March 2026
Operational controls None recorded without a removal date
Years with a record 11 calendar years (2016–2026)
Every line above is a count of records the US Coast Guard wrote, or a date it recorded. A blank resolution means none was recorded in this data; it does not establish that a deficiency is outstanding. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Identity

WDC9609
Flag
UNITED STATES
Maury page id
psix-54805

Documentation record

Registered dimensions (L × B × D)76.6 ft × 22.1 ft × 7.4 ft
Registered tonnagegross 78 / net 53
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderGULF CRAFT INC · PATTERSON, LA, UNITED STATES · built 1983
Hull materialAluminum
PropulsionDiesel Reduction
Hull shapeUNSPECIFIED
Hull configurationUNSPECIFIED
Hailing portNEW BEDFORD, MA
Trade endorsementsCoastwise, unrestricted
DocumentationExpired · issued 30 June 2004
Service, as the file records itPassenger (Inspected)
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it53 - Regulatory (Subpart C or D), Net Ton
78 - Regulatory (Subpart C or D), Gross Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 August 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
Vessel history report

A report is not offered for this hull. Its record holds only 2 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. What a sparse-record report looks like.

Inspection history · 22

10 March 2026 COI Inspection · Administrative Inspection
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 8322868
17 April 2025 Annual Inspection · Deficiency Check
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 8101208
5 February 2025 Administrative Inspection
Administrative · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 8075005
14 November 2024 Drydock Exam · Internal Structural Exam
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 8025705
16 April 2024 Annual Inspection · Deficiency Check · Internal Structural Exam
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 7873616
13 April 2023 Deficiency Check · Annual Inspection
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 7657931
17 November 2022 Drydock Exam · Internal Structural Exam · Deficiency Check
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 7590748
14 March 2022 Deficiency Check · Annual Inspection
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 7411560
2 November 2021 Deficiency Check · Examination of Repairs
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 7344733
5 April 2021 Internal Structural Exam · Drydock Exam
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 7146206
23 March 2021 COI Inspection · Internal Structural Exam
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 7146194
9 October 2020 Damage Survey · Deficiency Check
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 7077128
13 July 2020 Deficiency Check
Physical examination · Marine Safety Unit New Bedford · USCG Northeast District (CGD-NE) · Activity 7005075
19 May 2020 Drydock Exam
Physical examination · Marine Safety Unit New Bedford · USCG Northeast District (CGD-NE) · Activity 6955231
24 February 2020 Internal Structural Exam · In-Service Inspection · DAPI Audit · Annual Inspection · Drydock Extension · Examination of Repairs
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 6904016
1 April 2019 Annual Inspection · DAPI Audit
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 6653843
27 August 2018 Deficiency Check · Administrative Inspection
Physical examination · Navigation Center · Activity 6524292
27 March 2018 DAPI Audit · Deficiency Check · Annual Inspection
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 6370629
24 October 2017 Internal Structural Exam · Drydock Exam · Deficiency Check
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 6291095
6 April 2017 Internal Structural Exam · Annual Inspection · Deficiency Check
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 6109430
28 March 2016 Examination of Repairs · COI Inspection · Deficiency Check · Drydock Exam · Administrative Inspection · Internal Structural Exam
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 5830764
18 February 2016 Administrative Inspection · Deadweight Survey · Examination of Repairs
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 5822718

Deficiency record · 39

07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 10 March 2026 Resolved
The discharge ends of fuel tank vent pipes must be fitted with removable flame screens or flame arresters. The flame screens must consist of a single screen of corrosion resistant wire of at least 30 × 30 mesh. The flame screens or flame arresters must be of such size and design as to prevent reduction in the net cross sectional area of the vent pipe and permit cleaning or renewal of the flame screens or arrester elements. Renew the flame screen on the stbd side fuel vent.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 25 March 2026
Resolved 26 March 2026
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 10 March 2026 Resolved
Electrical equipment and installations must be suitable for the roll, pitch, and vibration of the vessel underway. Mount the electrical outlet located inside the galley cabinetry on the stbd side of the vessel.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 10 April 2026
Resolved 23 March 2026
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 10 March 2026 Resolved
Each connection to a conductor or terminal part of a conductor must be made within an enclosure. Remove or place within an enclosure, the marine cable located inside the galley cabinetry on the port side of the vessel.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 10 April 2026
Resolved 23 March 2026
02 - Structural Conditions › N/A - No Subsystem › Beams, frames, floors-op. damage
Issued 10 March 2026 Resolved
At each inspection for certification of a vessel, the owner or managing operator shall have the vessel ready for inspections of the hull structure including all accessible parts of the interior of the hull. Grind and reweld the identified cracked weld on the side shell in the fwd void, stbd side, 1st longitudinal from the deck, bay 1 from aft.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 10 April 2026
Resolved 23 March 2026
10 - Safety of Navigation › N/A - No Subsystem › Charts
Issued 17 April 2025 Resolved
As appropriate for the intended voyage, a vessel must carry adequate and up-to-date Charts. Charts were outdated.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 1 May 2025
Resolved 24 April 2025
01 - Certificates & Documentation › 012 - Crew Certificates › Certificate for medical first aid
Issued 16 April 2024 Resolved
To qualify for an MMC an applicant must meet the medical and physical standards in this section. Master did not possess a valid medical certificate. Provide a valid medical certificate prior to serving as master of the vessel. 46 CFR 10.215(a)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 30 April 2024
Resolved 17 April 2024
Resolution: Provided photo evidence of medical certificates. All sat.
01 - Certificates & Documentation › 011 - Ships Certificates › Other (certificates)
Issued 16 April 2024 Resolved
The Bridge-to-Bridge Act and regulations of this part apply to the following vessels in the navigable waters of the United States: every power driven vessel of 20 meters or over in length while navigating. Vessel's FCC Bridge-to-Bridge Certificate was expired. Provide valid Bridge-to-Bridge Certificate to the satisfaction of the attending USCG Marine Inspector. 47 CFR 80.1001(a)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 30 April 2024
Resolved 17 April 2024
Resolution: Provided photo evidence of valid FCC certificate. All sat.
01 - Certificates & Documentation › 011 - Ships Certificates › Other (certificates)
Issued 16 April 2024 Resolved
The provisions of Part III of Title III of the Communication Act require US vessels which transport more than six passengers for hire[...]to carry a radiotelephone installation complying with this subpart. Vessel's FCC Safety Radiotelephony Certificate was expired. Provide valid Safety Radiotelephony Certificate to the satisfaction of the attending USCG Marine Inspector. 47 CFR 80.901
Action required: 16 - Rectify deficiencies w/in 14 days
Due 30 April 2024
Resolved 17 April 2024
Resolution: Provided photo evidence of valid FCC Certificate. All sat.
10 - Safety of Navigation › N/A - No Subsystem › Nautical publications
Issued 16 April 2024 Resolved
As appropriate for the intended voyage, a vessel must carry adequate and up-to-date charts of large enough scale to make safe navigation possible. Vessel's charts were not up-to-date. Provide up-to-date charts of the vessel's operating area to the satisfaction of the attending USCG Marine Inspector. 46 CFR 184.420
Action required: 16 - Rectify deficiencies w/in 14 days
Due 30 April 2024
Resolved 18 April 2024
Resolution: Vessel provided photos of valid nautical chart for their operating area. All sat.
05 - Radio Communications › N/A - No Subsystem › VHF EPIRB
Issued 16 April 2024 Resolved
Each vessel that operates on the high seas, or that operates beyond three miles from the coastline of the Great Lakes, must have on board a FCC Type Accepted Category 1, 406 MHz EPIRB, installed to automatically float free and activate. Vessel's EPIRB hydrostatic release was expired. Vessel restricted to within 3 NM until a valid hydrostatic release has been installed to the satisfaction of the attending USCG Marine Inspector. 35 CFR 180.64
Action required: 705 - Other - as specified
Resolved 17 April 2024
Resolution: Provided photo evidence of proper EPIRB Installation. All sat.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 13 April 2023 Resolved
The number and identification of the items stowed inside, and their sizes, must be marked in clearly legible letters and numbers (at least 2" high) on each container for life jackets. No markings indicating number and size of life jackets stowed in the passenger seating boxes were applied.
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Due 27 April 2023
Resolved 13 April 2023
Resolution: Crew applied appropriate markings prior to completion of the inspection.
05 - Radio Communications › N/A - No Subsystem › Satellite EPIRB 406MHz/1.6GHz
Issued 13 April 2023 Resolved
The EPIRB's battery must be replaced after it is used, or before the date required by FCC regulations, whichever comes sooner. The EPIRB battery was expired upon inspection of the component. Replace the expired battery within 14 days.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 27 April 2023
Resolved 14 April 2023
Resolution: Operator provided photograph and receipt from Hercules Lifesaving in New Bedford, MA, attesting to replacement of the expired EPIRB battery.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 17 May 2022 Resolved
All ducts shall be of rigid permanent construction or fire proof material and reasonable gas tight from end to end. Holes were found in both port and starboard machinery space ventilation ducts proving closures ineffective in the event of a fire.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 31 May 2022
Resolved 24 May 2022
Resolution: Operator provided photos satisfactorily showing repair.
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 17 May 2022 Resolved
At each initial and subsequent inspection for certifications, the marine inspector shall examine all accessible internal structures of the vessel. Void #2 ("basement") identified fractured welds in the frame head bracket that connects the frame head to the shear strake. Frames 13 and 17 on port side, and frame 15 on starboard. Crew to inspect min of weekly, report any changes, repair at next dry-dock.
Action required: 705 - Other - as specified
Resolved 13 January 2023
Resolution: All repairs made. Images uploaded.
02 - Structural Conditions › N/A - No Subsystem › Beams, frames, floors-op. damage
Issued 5 April 2021 Resolved
#2 void space has cracked weld on the top longitudinal, starboard side aft of the space.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 1 November 2021
Resolved 2 November 2021
Resolution: Cracked weld was re-welded
02 - Structural Conditions › N/A - No Subsystem › Beams, frames, floors-op. damage
Issued 5 April 2021 Resolved
#2 void has a crack in the 2nd frame aft of the collision bulkhead, port side.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 1 November 2021
Resolved 2 November 2021
Resolution: Frame crack re-welded
11 - Life Saving Appliances › N/A - No Subsystem › Operational readiness of lifesaving appliances
Issued 23 March 2021 Resolved
Each vessel that operates on a limited coastwise route must be provided with lifesaving that will accommodate passengers onboard. Vessel is down one (1) IBA due to annual servicing. Vessel passenger count is reduced to seventy four (74) until IBA is placed back into service and to the satisfaction of an attending marine inspector.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 6 April 2021
Resolved 5 April 2021
Resolution: IBA serviced and installed satisfactorily aboard vessel. Reviewed servicing report, Sat.
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 23 March 2021 Resolved
The owner/operator must provide satisfactory evidence of annual fire fighting service. Provide service report from servicing agency.
Action required: 10 - Deficiency Rectified
Due 23 March 2021
Resolved 23 March 2021
Resolution: Provided annual fire fighting servicing report to MI.
11 - Life Saving Appliances › N/A - No Subsystem › Maintenance of Life Saving Appliances
Issued 23 March 2021 Resolved
The owner/operator must ensure servicing of IBA as required by 46 CFR 185.730. Provide annual servicing report from an approved facility.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 6 April 2021
Resolved 5 April 2021
Resolution: Provided evidence of servicing of IBA's.
09 - Working and Living Conditions › 091 - Living Conditions › Electrical devices
Issued 23 March 2021 Resolved
Electrical equipment must be installed and maintained to protect passengers, crew, from electrical hazards. Close openings in electrical outlet in main cabin as discussed.
Action required: 10 - Deficiency Rectified
Due 23 March 2021
Resolved 23 March 2021
Resolution: Closed openings in electrical outlet.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 23 March 2021 Resolved
Machinery and equipment installed on each vessel must be suitable for the vessel and its operation for the purpose intended. Repair/fix leak at bilge pump in engine room stbd main.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 6 April 2021
Resolved 27 March 2021
Resolution: Master opened pump casing and inspected. All sat. Installed new gasket and permatex. Operationally tested, sat. MI accepted pictures (documents) to clear.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 23 March 2021 Resolved
Non-conductive mats shall be provided on deck in front of switchboards. Provide non-conductive matting.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 6 April 2021
Resolved 23 March 2021
Resolution: Provided non-conductive matting on the deck in front of switchbaord. Accepted picture top clear (see docs).
02 - Structural Conditions › N/A - No Subsystem › Beams, frames, floors-corrosion
Issued 23 March 2021 Resolved
Two fractured fillet welds in forepeak, stbd side IWO sheer round bar to side shell. Repair not later than next dry dock
Action required: 705 - Other - as specified
Due 5 April 2021
Resolved 5 April 2021
Resolution: Repaired fractured weld to satisfaction of MI.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Auxiliary engine
Issued 1 April 2019 Resolved
EXHAUST PIPE FOR GENERATOR HOED IN ENGINE ROOM. PTC TEMP REPAIR TO SAT OF [name withheld] 50.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 11 April 2019
Resolved 1 May 2019
Resolution: RENEWED WITH NEW SECTION OF PIPE, STAINLESS.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Auxiliary engine
Issued 1 April 2019 Resolved
NEW GENERATOR INSTALLED, 40DEG C RATED VICE REQD 50 DEG C, PROVIDE WIEGHT OF OLD VS NEW. NEW GENERATOR TO BE RATED AT 50 DEG C.
Condition: Design Flaw
Action required: 50 - Rectify deficiencies w/in 30 days
Due 11 May 2019
Resolved 1 May 2019
Resolution: OBTAINED NEW DATA PLATE, MANF CONFIRMED GENERATOR COULD BE RATED AT 50DEG C AMBIENT DUE TO WINDING INSULATION.
10 - Safety of Navigation › N/A - No Subsystem › Magnetic compass
Issued 1 April 2019 Resolved
REPAIR MAGNETIC COMPASS LIGHT, NOT OPERATIONAL. MAINTAIN PORTABLE RED LIGHT AT OPERATING STATION.
Condition: Damaged By Earlier Event
Action required: 16 - Rectify deficiencies w/in 14 days
Due 25 April 2019
Resolved 1 May 2019
Resolution: RE-WIRED.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 1 April 2019 Resolved
MARK CAPACITY OF UPPER DECK AT 50 IAW VSL STABILITY LTR.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 25 April 2019
Resolved 1 May 2019
Resolution: MARKED.
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 1 April 2019 Resolved
WELDS FRACTURED, RAILING/BULWARK WELDS IWO BRACKETS; PORT EMBARKATION, AFT STBD CORNER, PORT FOWARD BRACKET DEFLECTED/STRAIGHTEN.
Condition: Damaged By Earlier Event
Action required: 50 - Rectify deficiencies w/in 30 days
Due 11 May 2019
Resolved 1 May 2019
Resolution: REPAIRED
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 1 April 2019 Resolved
BULWARK "BRACKET", PORT EMBARKATION DOOR FRACTURED;accepted temporary repair until next scheduled dry-dock, or until deemed unfit for service(further fractures) whichever occurs first.
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Due 16 December 2019
Resolved 20 May 2020
Resolution: Replaced in kind.
10 - Safety of Navigation › N/A - No Subsystem › Automatic Identification System (AIS)
Issued 27 August 2018 Resolved
Vsl is broadcasting: NAME with Vsl type precursor (NAME must not include Vsl type precursors, e.g. F/V, M/V) and incomplete dimension information (AIS Antenna Position “X” equals 0).
Condition: Invalid
Action required: 705 - Other - as specified
Due 27 September 2018
Resolved 21 September 2018
Navigation › Collision/Grounding Avoidance › Navigation Lights
Issued 27 March 2018 Resolved
Replace anchor lens
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 10 April 2018
Resolved 10 April 2018
Resolution: New lens installed.
Fire Fighting › Fire Main › Condition
Issued 27 March 2018 Resolved
Found discharge pipe with soft patches, repair / replace pipe.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 27 April 2018
Resolved 10 April 2018
Resolution: installed new piping.
Accommodation/Occupational Safety › Occupational Safety › Deck Rail
Issued 6 November 2017 Resolved
Weld cracked welds and stanchions marked forward at bow.
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Resolved 7 December 2017
Resolution: All deck railing was properly welded/replaced in kind.
Deck/Cargo › Holds/Tanks › Hatch
Issued 6 November 2017 Resolved
Replace safety line for watertight hatch for entrance of lazzarette.
Action required: 705 - Other - as specified
Due 6 December 2017
Resolved 6 December 2017
Resolution: Safety line for hatch was replaced and installed.
Pollution Prevention/Response › Prevention Equipment › Sewage System Piping
Issued 6 November 2017 Resolved
Properly secure vent pipe for black water tank located in lazzarette, use consistent material.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 6 December 2017
Resolved 6 December 2017
Resolution: New vent piping system was installed for black water tank located in Laz.
Documentation › Certificates/Documents › Permit, Other
Issued 6 April 2017 Resolved
Provide a certified marine chemist certificate for the lazarette space and make available for inspection.
Action required: 705 - Other - as specified
Due 7 April 2017
Resolved 11 April 2017
Operations/Management › Pollution › Control of Discharge of Sewage
Issued 6 April 2017 Resolved
Find source of H2S in the lazarette space and make adequate repairs to eliminate.
Action required: 701 - Prior to carriage of passengers/cargo
Due 6 April 2017
Resolved 7 April 2017
Documentation › Certificates/Documents › Certificate of Inspection
Issued 28 March 2016 Resolved
Prior to carrying passengers, complete th COI exam. COI expired 3/26/2016.
Action required: 705 - Other - as specified
Due 28 March 2016
Resolved 4 April 2016
Stability › Incline Test › General
Issued 28 March 2016 Resolved
Obtain a new stability letter or verify the existing letter is still valid by completing a deadweight survey and submit to MSC. Until the results have are returned the vessel is limited to 100 total persons and 10,000 lbs cargo.
Action required: 705 - Other - as specified
Due 28 April 2016
Resolved 1 March 2017

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.