MAURY USCG vessel records Sign in
← All vessels

SHANGRI-LA

SHANGRI-LA is a 2000 passenger vessel (inspected). The Coast Guard has recorded 60 inspections since 2000, most recently in August 2025, along with 115 deficiencies, 1 operational control and 1 casualty investigation in 2005.

Records from 2000 to 2025. Most recent: inspection, 13 August 2025.

Built
2000
Last inspected
13 August 2025
Documentation
Valid · documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

WDL7393
Flag
UNITED STATES
367453610
Maury page id
psix-5481

Inspections, by type

…with no type recorded4
Years with a record 24 calendar years (2000–2025)
The 60 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 1977.

Documentation record

Registered dimensions (L × B × D)64.0 ft × 31.0 ft × 7.0 ft
Registered tonnagegross 36 / net 28
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderGOLD COAST YACHTS INC · ST CROIX USVI · built 2000
Hull materialFRP (Fiberglass)
PropulsionAuxiliary Sail
Hull shapeShip
Hull configurationTwin Hull
Hailing portLAHAINA MAUI, HI
Trade endorsementsCoastwise, unrestricted
DocumentationValid · issued 1 December 2025 · expires 31 December 2026
Service, as the file records itPassenger (Inspected)
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it28 - Simplified, Net Ton
36 - Simplified, Gross Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 September 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.

Radio station licence

WDL7393MMSI 367453610 · active · compulsorily equipped · granted 26 August 2020, expires 26 August 2030 · licensed under a name not among this hull’s recorded names (not shown)
WDF4591MMSI 367453610 · expired · compulsorily equipped · granted 21 May 2010, cancelled 25 July 2020
WCZ7646MMSI not assigned · expired · compulsorily equipped · granted 18 April 2000, cancelled 19 June 2010
FCC Universal Licensing System ship-station file of 6 September 2026, matched to this hull on its US Official Number. Status and dates are the file’s own. The licensee is not read from the file and is not shown. A lapsed licence’s MMSI is still the number the vessel transmitted under while it was valid.

Inspection history · 60

13 August 2025 COI Inspection · Deficiency Check
Physical examination · OP location-Sector Honolulu Prevention Department- Wailuku · USCG Oceania District (CGD-O) · Activity 8208843
31 January 2025 Deficiency Check · Damage Survey
Physical examination · OP location-Sector Honolulu Prevention Department- Wailuku · USCG Oceania District (CGD-O) · Activity 8073278
9 September 2024 Drydock Exam · Examination of Repairs
Physical examination · OP location-Sector Honolulu Prevention Department- Kailua Kona · USCG Oceania District (CGD-O) · Activity 7997389
28 August 2024 Deficiency Check · Annual Inspection
Physical examination · OP location-Sector Honolulu Prevention Department- Wailuku · USCG Oceania District (CGD-O) · Activity 7992354
15 December 2023 DAPI Audit
Administrative · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 7840353
21 November 2023 Deficiency Check · Annual Inspection
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 7827905
30 March 2023 Deficiency Check · Administrative Inspection
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 7659494
12 October 2022 Deficiency Check · Annual Inspection
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 7576044
8 September 2022 Drydock Exam
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 7557434
18 February 2022 Administrative Inspection
Administrative · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 7398243
18 October 2021 Deficiency Check · Annual Inspection
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 7335025
16 September 2020 Drydock Exam · In-Service Inspection · Internal Structural Exam
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 7067104
28 August 2020 Deficiency Check · COI Inspection
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 7044264
21 October 2019 Deficiency Check · Annual Inspection
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 6839115
9 October 2019 In-Service Inspection · Administrative Inspection
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 6831831
29 August 2019 Administrative Inspection · Annual Inspection
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 6799255
28 November 2018 Construction Oversight · Administrative Inspection
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 6588380
4 October 2018 Administrative Inspection · Construction Oversight
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 6555852
2 October 2018 Annual Inspection · Administrative Inspection
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 6554298
7 September 2018 Drydock Exam · Administrative Inspection
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 6549637
9 April 2018 Deficiency Check
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 6388323
2 February 2018 Administrative Inspection · Deficiency Check
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 6348702
19 January 2018 Administrative Inspection · Deficiency Check
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 6340680
28 November 2017 Administrative Inspection · Annual Inspection
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 6315206
18 October 2016 Administrative Inspection · Annual Inspection · DAPI Audit
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 6031045
13 September 2016 Drydock Exam · Internal Structural Exam · Administrative Inspection
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 6261394
2 September 2015 Administrative Inspection · DAPI Audit · COI Inspection
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 5230598
22 October 2014 DAPI Audit · Annual Inspection
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 5010142
18 January 2012 Deficiency Check · DAPI Audit · Annual Inspection
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 4226910
21 October 2010 Deficiency Check
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 3874909
9 September 2010 Drydock Exam · Internal Structural Exam
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 3809696
3 September 2010 DAPI Audit · COI Inspection
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 3844637
2 December 2009 Deficiency Check · Annual Inspection · DAPI Audit
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 3643351
6 April 2009 Type not recorded
No type recorded · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 3447464
23 March 2009 Type not recorded
No type recorded · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 3441039
27 January 2009 Deficiency Check
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 3401234
20 November 2008 Hull Examination · Deficiency Check · In-Service Inspection
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 3370027
14 November 2008 Annual Inspection · DAPI Audit · Deficiency Check
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 3363089
24 September 2008 Administrative Inspection · Internal Structural Exam · Drydock Extension
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 3332058
7 November 2007 Annual Inspection
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 3095034
3 October 2006 Deficiency Check · Hull Examination
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 2798659
12 September 2005 COI Inspection
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 2490583
9 May 2005 Deficiency Check
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 2353618
13 February 2005 Type not recorded
No type recorded · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 2302300
24 November 2004 Annual Inspection
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 2247548
17 September 2004 Deficiency Check · Hull Examination
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 2278286
4 November 2003 Annual Inspection
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1941478
26 November 2002 Deficiency Check
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1711376
6 November 2002 Annual Inspection
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1701837
5 September 2002 Hull Examination
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1671935
18 June 2002 Deficiency Check
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1633557
7 May 2002 Drydock Extension
Administrative · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1613752
17 April 2002 Type not recorded
No type recorded · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1605974
28 January 2002 Deficiency Check
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1605156
6 November 2001 Re-Inspection
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1379621
10 October 2000 Deficiency Check
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1067746
19 September 2000 Deficiency Check
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1067745
14 September 2000 Plan Review "T" Boat · COI Inspection
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1376645
31 May 2000 Hull Examination
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1059752
31 May 2000 Plan Review "T" Boat · Hull Examination
Physical examination · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 1369767

Deficiency record · 115

99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 13 August 2025 Resolved
The owner shall be prepared to conduct tests and have the vessel ready for inspection of the following: On a sailing vessel all spars, standing rigging, running rigging, blocks, fittings, and sails. Support/chaffing plate for starboard superior diamond stay found with cathodic corrosion causing plate to bend and pull away from mast. Operator shall be required to follow recommendation of 3rd party rigging survey report dated 8/10/2025 to replace standing rigging and turnbuckles no later than October 1, 2025, remove all diamond chain plates for inspection/replacement when the mast is on the ground and coordinate with USCG to receive a 6-yr mast-out inspection credit accordance with USCG NVIC 02-16. 46 CFR 176.802(a)(3)
Action required: 705 - Other - as specified
Due 1 October 2025
Resolved 23 September 2025
Resolution: Mast un-stepped and rigging renewed by 3rd party surveyor [name withheld]
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 13 August 2025 Resolved
No marine employer shall engage or employ any individual to serve as a crew member unless the individual passes a chemical test for dangerous drugs for that employer. Employer did not have pre-employment test results and proof of drug awareness training for 02 crew members. Provide satisfactory proof that all crew members have passed pre-employment testing and completed drug awareness training prior to those individuals serving in a crew member role on the vessel. 46 CFR 16.210(a)
Action required: 50 - Rectify deficiencies w/in 30 days
Due 10 September 2025
Resolved 23 September 2025
Resolution: Pre employment training and drug testing completed for (01) new employee and provided to CG. The second crew member identified was never hired by company.
09 - Working and Living Conditions › 092 - Working Conditions › Anchoring devices
Issued 31 January 2025 Resolved
A vessel must be fitted with ground tackle and mooring lines necessary for the vessel to be safely anchored or moored. Vessel reported broken anchor chain during storm. Anchor chain requires replacement. 46 CFR 183.400
Action required: 17 - Rectify deficiencies prior to departure
Due 11 February 2025
Resolved 10 February 2025
Resolution: Vessel replaced anchor chain with new 3/8" stainless G4 rating. 300ft chain.
07 - Fire Safety › N/A - No Subsystem › Fixed fire extinguishing installation
Issued 28 August 2024 Resolved
The following spaces must be equipped with a fixed gas fire extinguishing system in compliance with 181.410: A space containing machinery powered be gasoline. Fixed gas fire extinguishing system (Fireboy) for port amidship generator space. Provide a certified technician service report & demonstrate all shutdowns, alarms, and overrides to the attending USCG marine inspector. 46 CFR 181.400(a)(4)
Action required: 705 - Other - as specified
Due 13 December 2024
Resolved 23 September 2025
Resolution: Gen System non-operational and out of service. No fire extinguishing system required while system in out of service. All wiring to gen disconnected and fuel removed.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Auxiliary engine
Issued 28 August 2024 Resolved
Machinery and equipment installed on each vessel must be suitable for the vessel and its operation and for the purpose intended. Generator inoperable from start up panel. Make generator operational as designed. 46 CFR 182.100
Action required: 705 - Other - as specified
Due 13 December 2024
Resolved 23 September 2025
Resolution: Gen System non-operational, unserviceable and removed from operations. The HVAC and water maker which was serviced by the generator remain inoperable.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 28 August 2024 Resolved
The owner shall be prepared to conduct tests and have the vessel ready for inspection of the following: On a sailing vessel all spars, standing rigging, running rigging, blocks, fittings, and sails. Support/chaffing plate for starboard superior diamond stay found with cathodic corrosion causing plate to bend and pull away from mast. Operator shall schedule a 3rd party rigging surveyor to adequately assess the safe condition of their sail rigging system in accordance with USCG NVIC 02-16, provide the survey report prior to operating under sail. 46 CFR 176.802(a)(3)
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 1 October 2024
Resolution: Aluminum doublber plate serve as spacers to keep stainless through bar from migrating port to starboard. No issues from current set up as per 3rd party rigging surveyor. Report attached.
09 - Working and Living Conditions › 091 - Living Conditions › Medical Equipment
Issued 28 August 2024 Resolved
A vessel must carry either a first-aid kit approved under approval series 160.041 or a kit with equivalent contents and instructions. First aid kit is incomplete with expired contents. Provide USCG-approved kit or a kit that complies with the list in 46 CFR 160.041. 46 CFR 184.710
Action required: 50 - Rectify deficiencies w/in 30 days
Due 27 September 2024
Resolved 14 October 2024
Resolution: New approved first aid kit installed on vessel
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 28 August 2024 Resolved
The owner shall submit the following plans,that are applicable to the vessel as determined by the OCMI: On sailing vessels: (i) Masts, including integration into the ship's structure; and (ii) Rigging plan showing sail areas and centers of effort as well as the arrangement, dimensions, and connections of the standing rigging. Provide complete updated 2024 Rigging PMP for vessel. 46 CFR 177.202(b)(12)
Action required: 50 - Rectify deficiencies w/in 30 days
Due 27 September 2024
Resolved 1 October 2024
Resolution: Received updated PMP YR 2024
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 28 August 2024 Resolved
Electrical equipment must be installed to protect from electrical hazards. Grounding wires broken on single side band antenna and mast radio/lighting require proper reattachment. Conduit for mast wiring also broken exposing wiring. Requires replacement. 46 CFR 183.200
Action required: 50 - Rectify deficiencies w/in 30 days
Due 27 September 2024
Resolved 14 October 2024
Resolution: New conduit installed, and grounding wires renewed.
18 - Maritime Labour Convention (Not Applicable to PSC Exams conducted in the U.S.) › N/A - No Subsystem › Ship's occupational safety and health policies and programmes
Issued 28 August 2024 Resolved
Each EAP education program must include display and distribution of informational material; a community service hot-line telephone number for crew member assistance, and display and distribution of the employer's policy regarding drug and alcohol use in the workplace. Service hot-line numbers required to be posted on vessel. 46 CFR 16.401
Action required: 50 - Rectify deficiencies w/in 30 days
Due 27 September 2024
Resolved 14 October 2024
Resolution: EAP service hotline installed onboard.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Operation of machinery
Issued 21 November 2023 Resolved
All machinery and equipment must be installed and maintained in such a manner as to afford adequate protection from causing fire, explosion, machinery failure, and personnel injury. Exhaust leak located on port engine exhaust system. Repair exhaust piping to provide leak free exhaust system from port engine. 46 CFR 182.100
Action required: 17 - Rectify deficiencies prior to departure
Resolved 30 November 2023
Resolution: Leak free exhaust provided.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Operation of machinery
Issued 21 November 2023 Resolved
All machinery and equipment must be installed and maintained in such a manner as to afford adequate protection from causing fire, explosion, machinery failure, and personnel injury. Stuffing box starboard side shaft leaking. Make starboard shaft stuffing box leak free. 46 CFR 182.100
Action required: 17 - Rectify deficiencies prior to departure
Resolved 30 November 2023
Resolution: Shaft stuffing box made leak free.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 21 November 2023 Resolved
Portable and semi-portable extinguishers must be inspected and maintained in accordance with NFPA 10. The owner or managing operator must provide satisfactory evidence of the required servicing to the marine inspector. 46 CFR 176.810(b)(1)
Action required: 17 - Rectify deficiencies prior to departure
Resolved 1 December 2023
Resolution: Portable fire extinguishers serviced.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Operation of machinery
Issued 21 November 2023 Resolved
Machinery and equipment installed on each vessel must be suitable for the vessel and its operation and for the purpose intended. Generator was not operational. Make generator operational as designed. 46 CFR 182.100
Action required: 50 - Rectify deficiencies w/in 30 days
Due 21 December 2023
Resolved 4 March 2024
Resolution: Generator operational.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 21 November 2023 Resolved
[withheld — contains personal information; the deficiency system, dates, and resolution status are shown above]
Action required: 50 - Rectify deficiencies w/in 30 days
Due 21 December 2023
Resolved 15 December 2023
Resolution: Completed satisfactory DAPI audit.
01 - Certificates & Documentation › 011 - Ships Certificates › Other (certificates)
Issued 21 November 2023 Resolved
The owner or managing operator of a vessel shall ensure that the vessel complies with the laws and regulations applicable to the vessel and that the vessel is otherwise satisfactory for the intended service. The inspection may include an inspection of the following items: Certificates issued by the FCC. FCC Safety Radio Certificate not valid. Provide inspection and valid FCC Safety Radio Certificate. 46 CFR 176.402
Action required: 50 - Rectify deficiencies w/in 30 days
Due 21 December 2023
Resolved 4 March 2024
Resolution: Safety Radio Cert provided.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 21 November 2023 Resolved
The OCMI may require the vessel to get underway. Get underway in presence of marine inspector to conduct drills. 46 CFR 176.404(a)
Action required: 17 - Rectify deficiencies prior to departure
Resolved 19 December 2023
Resolution: Drills conducted.
05 - Radio Communications › N/A - No Subsystem › VHF EPIRB
Issued 21 November 2023 Resolved
Vessel is required to ensure the EPIRB's battery is replaced after it is used, or before the date required by FCC regulations in 47 CFR part 80, whichever comes sooner. Vessel's EPIRB battery was past its expiration date. Replace battery to satisfaction of attending Coast Guard Marine Inspector. Vessel restricted to within three mile of shore. 46 CFR 185.728
Action required: 705 - Other - as specified
Resolved 19 December 2023
Resolution: New EPIRB provided.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 21 November 2023 Resolved
The EPIRB test required shall be logged or otherwise documented monthly. Vessel unable to provide log for EPIRB tests. Provide monthly EPIRB test log. 46 CFR 185.728(c)
Action required: 50 - Rectify deficiencies w/in 30 days
Due 21 December 2023
Resolved 19 December 2023
Resolution: EPIRB test logged.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 21 November 2023 Resolved
Firefighting drills and training shall be logged or otherwise documented for review by the Coast Guard upon request. The drill entry shall include the following information: Date of the drill and training; and general description of the drill scenario and training topics. Vessel unable to provide logs for fire fighting drills and training. 46 CFR 185.524(d)
Action required: 50 - Rectify deficiencies w/in 30 days
Due 21 December 2023
Resolved 19 December 2023
Resolution: Drills logged.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 21 November 2023 Resolved
A vessel must be provided with a satisfactory arrangement for draining any watertight compartment, other than small buoyancy compartments, under all practicable conditions. Bilge system inoperable in starboard midship. Make bilge pumps operate as designed from bilge float. 46 CFR 182.500 (a)
Action required: 17 - Rectify deficiencies prior to departure
Resolved 30 November 2023
Resolution: Bilge pump operates from bilge float switch.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 21 November 2023 Resolved
Conditions of operations as may be determined by the cognizant Officer in Charge Marine Inspection (OCMI). Grills on vessel built of general purpose resin must have a dedicated 40-B:C fire extinguisher and grill shall be installed so that it can be jettisoned from the vessel with a single action while on fire, such as a pull cable to detach it from the deck railing. See Work Instruction 46 for details. 46 CFR 176.103
Action required: 50 - Rectify deficiencies w/in 30 days
Due 21 December 2023
Resolved 19 December 2023
Resolution: Grill removed.
10 - Safety of Navigation › N/A - No Subsystem › Nautical publications
Issued 21 November 2023 Resolved
[withheld — contains personal information; the deficiency system, dates, and resolution status are shown above]
Action required: 50 - Rectify deficiencies w/in 30 days
Due 21 December 2023
Resolved 12 December 2023
Resolution: Pubs provided.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 21 November 2023 Resolved
In systems and applications where flexible hoses are permitted to be clamped: Double hose clamping is required where practicable. Missing double hose clamps on bilge suction and discharge. Provide double hose clamps on all bilge lines. 46 CFR 182.410 (d) (1)
Action required: 50 - Rectify deficiencies w/in 30 days
Due 21 December 2023
Resolved 30 November 2023
Resolution: Double hose clamps provided.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Operation of machinery
Issued 21 November 2023 Resolved
Shutoff valves, installed so as to close against the fuel flow, must be fitted in the fuel supply lines at the tank connection. The shutoff valve at the tank must be manually operable from outside the compartment in which the valve is located. The vessel's port fuel shutoff valve was not fully operable. Service and prove proper operation of the port fuel shutoff valve. 46 CFR 182.455(b)(4)
Action required: 17 - Rectify deficiencies prior to departure
Resolved 30 November 2023
Resolution: Fuel shut off operational.
07 - Fire Safety › N/A - No Subsystem › Fire detection and alarm system
Issued 21 November 2023 Resolved
All fiber reinforced plastic vessels constructed with general purpose resins must be fitted with a smoke activated fire detection system of an approved type (meeting 46 CFR 181.450), installed in accordance with 76.27 in subchapter H of this chapter in accommodation spaces and service spaces. Vessel does not have interconnected fire detection system for required spaces. Interconnected fire detection system must be in compliance with 46 CFR 181.450. Provide approved interconnected fire detection system and install to the satisfaction of the attending marine inspector. 46 CFR 177.410(c)(3)(ii)
Action required: 50 - Rectify deficiencies w/in 30 days
Due 21 December 2023
Resolved 4 March 2024
Resolution: Smoke activated fire detection system operational.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 30 March 2023 Resolved
The cognizant OCMI may require that a vessel and its equipment undergo any additional test or inspection deemed reasonable and necessary to determine that the vessel and its equipment are suitable for the service in which they are to be employed. Annual inspection completed on 12 Oct 2022 with deficiency issued to provide full rigging inventory of all old and new rigging components, inspections, and rigging details. Ensure to log all inspections in accordance with vessel PMP. Keep copy of PMP on board vessel at all times and submit revised version of PMP to [name withheld] The deficiency from 12 Oct 2022 has not been cleared. Updated and accurate PMP has not been provided. The vessel shall not fly sails after 31 March 2023 with passengers onboard until a third party rig inspection is completed IAW NVIC 02-16. 46 CFR 176.840
Action required: 705 - Other - as specified
Resolved 5 April 2023
Resolution: PMP provided.
05 - Radio Communications › N/A - No Subsystem › VHF EPIRB
Issued 12 October 2022 Resolved
Vessel that operates on the high seas must have on board a FCC EPIRB installed to automatically float free. Hydrostatic release was expired. Provide valid hydrostatic release. Vessel restricted to operating within three miles from land. 46 CFR 180.64
Action required: 705 - Other - as specified
Resolved 17 November 2022
Resolution: New EPIRB hydrostatic release provided.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 12 October 2022 Resolved
Each ring buoy with floating light must have lanyard of at least 3 ft but not more than 6 ft. Lanyard for ring buoy floating light too long. Provide lanyard of proper length. 46 CFR 180.70
Action required: 50 - Rectify deficiencies w/in 30 days
Due 12 November 2022
Resolved 17 November 2022
Resolution: Proper line provided for ring buoy.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 12 October 2022 Resolved
Each life jacket must be marked with type 1 retro reflective material. 13 life jackets had worn/aged retro reflective materials. Provide new retro reflective materiel for 13 life jackets. 46 CFR 185.604(h)
Action required: 50 - Rectify deficiencies w/in 30 days
Due 12 November 2022
Resolved 17 November 2022
Resolution: Retro tape provided for lifejackets.
11 - Life Saving Appliances › N/A - No Subsystem › Other (life saving)
Issued 12 October 2022 Resolved
The name of the vessel must be marked on each side of the life float. The The number of persons capacity must be marked on each life float. Name of vessel and number missing from each life float. Provide vessel name and number capacity. 46 CFR 185.604(a) 46 CFR 185.604(e)
Action required: 50 - Rectify deficiencies w/in 30 days
Due 12 November 2022
Resolved 17 November 2022
Resolution: Name provided on life floats.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 12 October 2022 Resolved
Each ring life buoy must be marked with retro reflective material. Worn/aged retro reflective materials on ring. Provide new retro reflective materiel for ring buoy. 46 CFR 185.604(i)
Action required: 50 - Rectify deficiencies w/in 30 days
Due 12 November 2022
Resolved 17 November 2022
Resolution: Retro tape provided for ring buoy.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 12 October 2022 Resolved
The fuel shutoff valve at the tank must be manually operable from outside the compartment in which the valve is located. Fuel shutoff would not fully close. Provide fully operational fuel shutoff. 46 CFR 182.455(b)(4)
Action required: 17 - Rectify deficiencies prior to departure
Resolved 17 October 2022
Resolution: Fuel shutoff fully operational.
11 - Life Saving Appliances › N/A - No Subsystem › Other (life saving)
Issued 12 October 2022 Resolved
The number and identification of the items stowed inside and their sizes, must be marked in clearly legible letters and number on each container for life jackets. Marking for life jacket storage missing. Provide marking for life jacket stowage. 46 CFR 185.604(f)
Action required: 50 - Rectify deficiencies w/in 30 days
Due 12 November 2022
Resolved 27 October 2022
07 - Fire Safety › N/A - No Subsystem › Fixed fire extinguishing installation
Issued 12 October 2022 Resolved
A pre-engineered fixed gas fire extinguishing system must be installed in accordance with the manufactures instructions. Port side engine room pre-engineered fixed gas fire extinguishing system was discharged during inspection. Provide new pre-engineered fixed gas fire extinguishing system for port side engine room. 46 CFR 181.420(a)
Action required: 17 - Rectify deficiencies prior to departure
Resolved 12 October 2022
Resolution: New bottle installed.
10 - Safety of Navigation › N/A - No Subsystem › Nautical publications
Issued 12 October 2022 Resolved
[withheld — contains personal information; the deficiency system, dates, and resolution status are shown above]
Action required: 50 - Rectify deficiencies w/in 30 days
Due 17 December 2022
Resolved 19 March 2023
Resolution: Nav pubs provided.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 12 October 2022 Resolved
Sail Rigging Preventative Maintenance Plan (PMP) must be updated and onboard vessel at all times. PMP not currently updated. Provide full rigging inventory of all old and new rigging components, inspections, and rigging details. Ensure all to log all inspections in accordance with vessel PMP. Keep copy of PMP on board vessel at all times and submit revised version of PMP to [name withheld]. 46 CFR 176.802
Action required: 50 - Rectify deficiencies w/in 30 days
Due 17 December 2022
Resolved 5 April 2023
Resolution: PMP Provided.
07 - Fire Safety › N/A - No Subsystem › Fire detection and alarm system
Issued 18 October 2021 Resolved
All Fiber Reinforced Plastic(FRP) vessels constructed with general purpose resins must be fitted with a smoke activated fire detection system of an approved type. Due to generator on vessel being non operational, fire detection system is non operational. AC systems that rely on generator are not operational including general alarm, fire detection, emergency lighting. Repair generator and perform function tests on all systems that run on AC prior to taking passengers. 46 CFR 177.410(c)(3)
Action required: 17 - Rectify deficiencies prior to departure
Resolved 27 October 2021
Resolution: Generator repaired. Fire detection and emergency lighting operational.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 18 October 2021 Resolved
A visual indicator must be provided at the operating station to indicate when any automatic bilge pump is operating. Mid ship port and starboard bilge pump indication not operational at operating station. Provide operational auto bilge indicators. 46 CFR 182.530(c)
Action required: 50 - Rectify deficiencies w/in 30 days
Due 18 November 2021
Resolved 27 November 2021
Resolution: New wiring installed. Operational.
09 - Working and Living Conditions › 092 - Working Conditions › Warning notices
Issued 18 October 2021 Resolved
All escape hatches used by means of escape must be marked on both side in clearly legible 2 inch letter "EMERGENCY EXIT, KEEP CLEAR". Interior emergency escape marking in both port and starboard state room missing. Provide proper emergency escape marking. 46 CFR 185. 606
Action required: 50 - Rectify deficiencies w/in 30 days
Due 18 November 2021
Resolved 18 November 2021
Resolution: Escape hatches marked.
07 - Fire Safety › N/A - No Subsystem › Fixed fire extinguishing installation
Issued 18 October 2021 Resolved
A pre-engineered fixed gas fire extinguishing system must be installed in accordance with the manufacturers instructions. New Fire Boy bottle of 400 CUFT installed while COI states 475 CUFT and old bottle was 475 CUFT. Drawings also indicate the original bottle was 475 CUFT. Area of engine rooms could not be confirmed. Provide drawings/plans of engine room area to confirm pre-engineered system of 400 CUFT will cover space. 46 CFR 181.420
Action required: 17 - Rectify deficiencies prior to departure
Resolved 27 October 2021
Resolution: Drawing of cubic foot submitted. Space has been measured and is 396 cubic foot.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 18 October 2021 Resolved
A vessel with more that one passenger deck and a vessel with overnight accommodations must have the public address system operable from the operating station. PA system not operational. Provide operational PA system. 46 CFR 184.610(c)
Action required: 50 - Rectify deficiencies w/in 30 days
Due 18 November 2021
Resolved 27 November 2021
Resolution: New speakers installed. Operational.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 18 October 2021 Resolved
At each inspection the owner shall be prepared to have the vessel ready for inspection of the standing rigging in accordance with their Preventative Maintenance Plan. Furler disassembly to inspect standing rigging has not been completed in this calendar year. Make standing forestay rigging ready for inspection and provide report of condition. 46 CFR 176.802
Action required: 50 - Rectify deficiencies w/in 30 days
Due 18 November 2021
Resolved 14 November 2021
Resolution: Furler disassembled and inspected IAW PMP.
01 - Certificates & Documentation › 013 - Documents › Signs, indications
Issued 28 August 2020 Resolved
Emergency instruction list missing. Post emergency instruction list.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 28 September 2020
Resolved 3 November 2020
Resolution: Emergency list posted.
01 - Certificates & Documentation › 013 - Documents › Signs, indications
Issued 28 August 2020 Resolved
Waste management plan missing. Post waste management plan.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 28 September 2020
Resolved 3 November 2020
Resolution: Waste management plan provided.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 28 August 2020 Resolved
Alcohol testing devices expired. Provide valid alcohol testing devices.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 28 September 2020
Resolved 3 November 2020
Resolution: Alcohol testing device provided.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 28 August 2020 Resolved
Life jacket storage marking missing. Provide marking for both child and adult storage of life jackets.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 28 September 2020
Resolved 3 November 2020
Resolution: Markings provided.
11 - Life Saving Appliances › N/A - No Subsystem › Maintenance of Life Saving Appliances
Issued 28 August 2020 Resolved
Lens/Light for 01 life float removed from service. Provide 01 new life float light with a lanyard of at least 18 feet in length.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 28 September 2020
Resolved 16 November 2020
Resolution: New lens and line provided.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 28 August 2020 Resolved
Portable and pre-engineered fixed fire fighting have not been serviced in past year. Provide service certificate of fire fighting appliances.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 28 September 2020
Resolved 3 November 2020
Resolution: Servicing conducted.
10 - Safety of Navigation › N/A - No Subsystem › Magnetic compass
Issued 28 August 2020 Resolved
Compass light not operational. Provide compass light.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 28 September 2020
Resolved 28 September 2020
Resolution: Compass light was replaced and is operational.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 28 August 2020 Resolved
Current Light list, Coast Pilot, and Tide Tables not on vessel. Provide local extracts of publications for area to be transited.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 28 September 2020
Resolved 3 November 2020
Resolution: Pubs provided.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 28 August 2020 Resolved
Oil change pump hot-wired onto vessel battery. Remove unapproved wiring that leads directly from battery to final load source.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 28 September 2020
Resolved 3 November 2020
Resolution: Oil change pump and wiring removed.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 28 August 2020 Resolved
Natural ventilation has mechanical closure that is not allowing for full closure. Make repairs to natural ventilation closures to ensure full closure of natural ventilation.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 28 September 2020
Resolved 28 September 2020
Resolution: Aft port and starboard deck air closures caps where replaced and are able to fully close.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 28 August 2020 Resolved
Running rust noted where chain plate meets port side of furler. Remove paint for further visual exam. NDT Dye-pen may need to be performed to rule out cracking based on visual inspection. Complete at upcoming dry dock.
Action required: 705 - Other - as specified
Resolved 28 September 2020
Resolution: Cleaned and examined chain plate on port side of furler. No deficiencies found, NDT not required.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 28 August 2020 Resolved
Sail Rigging Preventative Maintenance Plan (PMP) not being utilized as designed. Daily, weekly, monthly, and semi-annual inspections not being conducted and/or logged as plan states in the past year. Provide full rigging survey at upcoming dry dock. Provide full rigging inventory of all old and new rigging components. Begin to log all inspections in accordance with vessel PMP. Complete at upcoming dry dock.
Action required: 705 - Other - as specified
Resolved 17 December 2020
Resolution: PMP provided. Log provided.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 9 October 2019 Resolved
Port engine shutdown solenoid failed to secure engine. Repair/renew solenoid in accordance with 46 CFR 176.804(b)
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 21 October 2019
Resolution: Port engine shutdown solenoid operated correctly. Fireboy system secured engine when tested.
07 - Fire Safety › N/A - No Subsystem › Means of escape
Issued 9 October 2019 Resolved
Port and stbd forward berth overhead emergency escapes lacked sufficient means of access. Provide satisfactory ladder in accordance with 46 CFR 177.500(j). Passengers are not allowed in forward berths.
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 10 November 2019
Resolved 28 September 2020
Resolution: Satisfactory ladder provided.
07 - Fire Safety › N/A - No Subsystem › Means of escape
Issued 9 October 2019 Resolved
Interior side of escape hatches in forward and aft port/stbd accommodation spaces were not marked. Mark in accordance with 46 CFR 185.606.
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 10 November 2019
Resolved 28 September 2020
Resolution: Markings provided.
07 - Fire Safety › N/A - No Subsystem › Fixed fire extinguishing installation
Issued 9 October 2019 Resolved
Generator compartment Fireboy did not secure generator when tested. Prove correct operation of Fireboy in accordance with 46 CFR 181.420.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 10 November 2019
Resolved 28 September 2020
Resolution: Fire Boy testing completed. All sat.
07 - Fire Safety › N/A - No Subsystem › Fire-dampers
Issued 29 August 2019 Resolved
Port and stbd engine compartment ventilation closures did not close completely. Prove correct operation in accordance with 46 CFR 176.810.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 21 October 2019
Resolution: Port and stbd engine ventilation closures were satisfactory.
Lifesaving › Lifejacket/PFD (General) › Quantity
Issued 28 November 2017 Resolved
Vessel has only 52 satisfactory PFDs. Limited to 52 total persons in accordance with 46CFR 180.71.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Resolved 19 January 2018
Resolution: PFDs provided.
Fire Fighting › Fixed Fire Detection System › Alarms
Issued 28 November 2017 Resolved
Fire detection system required by 46CFR 177.410(3) is inoperable. Rounds of spaces serviced by system must be conducted every 15 minutes while passengers are onboard.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 19 February 2018
Resolved 9 April 2018
Resolution: Fire detection panel installed.
Documentation › Certificates/Documents › FCC Safety Radiotelephony Certificate
Issued 28 November 2017 Resolved
Safety Certificate required by 47 CFR is expired. Provide current certificate onboard.
Condition: Invalid
Due 19 February 2018
Resolved 2 February 2018
Resolution: Certificate provided.
Fire Fighting › Fixed Fire Detection System › Smoke Detectors
Issued 2 September 2015 Resolved
Smoke detection system need to operate properly.
Due 2 October 2015
Resolved 18 October 2016
Resolution: Smoke detection system is operating properly however it continues to be fail randomly. Vessel is not aloud to carry passengers overnight until system is more reliable. Vessel owner is looking into new system.
Engineering › Bilge Water Management System › Pump
Issued 2 September 2015 Resolved
All bilge pumps must be UL listed or CG approved.
Due 9 September 2015
Resolved 18 October 2016
Resolution: All bilge pump are UL listed.
Lifesaving › Hand Flares › Quantity
Issued 2 September 2015 Resolved
Vessel must have proper number of distress signals (12).
Due 9 September 2015
Resolved 9 September 2015
Resolution: Vessel has required number of flares.
Navigation › Piloting/Steering › US Coast Pilot
Issued 2 September 2015 Resolved
Provide an up to date coast pilot and light list.
Due 2 October 2015
Resolved 17 October 2015
Resolution: Vessel provided new pubs.
Lifesaving › Buoyant Apparatus › Floating Electric Waterlight
Issued 18 January 2012 Resolved
Renew batteries in BA and Life Float Water lights.
Action required: 705 - Other - as specified
Due 27 January 2012
Resolved 31 January 2012
Communications › Radio Communications › EPIRB
Issued 18 January 2012 Resolved
Renew battery. Prior to vsl operating beyond 3NM from shore.
Action required: 705 - Other - as specified
Resolved 31 January 2012
Engineering › Bilge Water Management System › Pump
Issued 18 January 2012 Resolved
Prove operation of auto bilge pump indicator lights for mid-ship voids both port and stbd.
Action required: 705 - Other - as specified
Due 27 January 2012
Resolved 31 January 2012
Construction/Loadline › Structures › Superstructure
Issued 18 January 2012 Resolved
Provide written documentation recording maintenance, inspection, and replacement of standing rigging components.
Action required: 705 - Other - as specified
Due 27 January 2012
Resolved 2 August 2012
Documentation › Safety Management System › Essential Sailing Instructions Documentation
Issued 9 September 2010 Resolved
Provide proof of completed in house inspection of rigging report/survey to the satisfaction of the attending USCG Marine Inspector prior to receiving credit for dry-dock.
Action required: 705 - Other - as specified
Due 21 October 2010
Resolved 20 October 2010
Resolution: Recived self inspection program and checksheets. Recived 3rd party inspection rpt.
Navigation › Piloting/Steering › US Coast Pilot
Issued 2 December 2009 Resolved
UPDATE COAST PILOT AND LIGHT LIST
Condition: Unknown
Action required: 705 - Other - as specified
Due 2 January 2010
Resolved 4 February 2010
Documentation › Markings/Placards › Lifejacket Placard
Issued 2 December 2009 Resolved
PROVIDE LIFEJACKET DONNNIG PLACARD.
Condition: Unknown
Action required: 705 - Other - as specified
Due 2 January 2010
Resolved 4 February 2010
Navigation › Piloting/Steering › Compass Deviation Table
Issued 2 December 2009 Resolved
PROVIDE COMPASS DEVIATION TABLE.
Condition: Unknown
Action required: 705 - Other - as specified
Due 2 January 2010
Resolved 19 February 2010
Accommodation/Occupational Safety › Medical/First Aid › Medicine Chest
Issued 2 December 2009 Resolved
UPDATE FIRST AID KIT INVENTORY.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 2 January 2010
Resolved 19 February 2010
Lifesaving › Lifefloat › Painter
Issued 2 December 2009 Resolved
REPAIR PAINTER HOUSING
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 2 January 2010
Resolved 4 February 2010
Lifesaving › Lifejacket/PFD (Type I) › Condition
Issued 2 December 2009 Resolved
PROVIDE 2 ADULT PFD's
Condition: Unknown
Action required: 705 - Other - as specified
Due 7 December 2009
Resolved 3 December 2009
Engineering › Fuel Oil Storage/Transfer System › Hose
Issued 2 December 2009 Resolved
REPLACE ALL FLEXIBLE FUEL HOSE IN EXCESS OF 30" WITH NON FERROUS METALLIC PIPING OR SAE J 1942 FUEL HOSE ASSEMBLIES.
Condition: Design Flaw
Action required: 705 - Other - as specified
Due 2 January 2010
Resolved 3 December 2009
Construction/Loadline › Penetrations › Valve Flange
Issued 20 November 2008 Resolved
Conduct sea trails and prove proper operation of rigging. Prior to completion of credit dry-dock.
Condition: Unknown
Action required: 705 - Other - as specified
Due 30 December 2008
Resolved 15 December 2008
Stability › Intact Righting Energy › General
Issued 20 November 2008 Resolved
Provide rigging report, including detailed description of the rig and associated gear. Including manufacturers purchase and installation dates of all components. Prior to completion of credit dry-dock.
Condition: Unknown
Action required: 705 - Other - as specified
Due 31 December 2008
Resolved 27 January 2009
Lifesaving › Lifejacket/PFD (Type I) › Quantity
Issued 14 November 2008 Resolved
PROVIDE 3 ADULT PFD's.
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Due 14 December 2008
Resolved 16 December 2008
Lifesaving › Lifefloat › Float Free
Issued 14 November 2008 Resolved
RERIG PAINTER SYSTEM ON LIFE FLOATS.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 17 December 2008
Resolved 16 December 2008
Fire Fighting › Fixed Gas Fire Extinguishing System › Quantity of Gas
Issued 14 November 2008 Resolved
RENEW FIRE FIGHTING CERTIFICATE.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 17 December 2008
Resolved 16 December 2008
Personnel › Training › First Aid/CPR
Issued 14 November 2008 Resolved
RENEW CPR AND FIRST AID QUALIFICATION.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 14 December 2008
Resolved 16 December 2008
Electrical › Lighting (emergency) › Lighting Fixture
Issued 14 November 2008 Resolved
PROVE STBD. EMERGENCY LIGHTING.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 14 December 2008
Resolved 16 December 2008
Accommodation/Occupational Safety › Medical/First Aid › Medicine Chest
Issued 12 September 2005 Resolved
Update meds in first aid kit as needed.
Due 12 October 2005
Resolved 10 October 2005
Fire Fighting › Fixed Gas Fire Extinguishing System › Quantity of Gas
Issued 12 September 2005 Resolved
Recharge port fixed fire extinguishing supply bottle.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 14 September 2005
Communications › Radio Communications › EPIRB
Issued 12 September 2005 Resolved
re-new EPIRB battery.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 14 September 2005
Electrical › Lighting (emergency) › Lighting Fixture
Issued 12 September 2005 Resolved
Prove emergency lighting STBD side
Action required: 705 - Other - as specified
Due 23 September 2005
Resolved 23 September 2005
Fire Fighting › Fixed Fire Detection System › Control Valve
Issued 12 September 2005 Resolved
Prove vent shutdownds for fixed firefighting system.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 14 September 2005
Lifesaving › Lifefloat › Retroreflective Material
Issued 12 September 2005 Resolved
Renew retroflective material on lifefloats as needed.
Due 12 October 2005
Resolved 12 October 2005
Lifesaving › Lifejacket/PFD (Type I) › Retroreflective Material
Issued 12 September 2005 Resolved
Renew retroflective tape on two adult PFD's.
Due 12 October 2005
Resolved 10 October 2005
Operations/Management › Drills/Instruction › Man Overboard Recovery
Issued 12 September 2005 Resolved
Post emergency instructions.
Due 12 October 2005
Resolved 10 October 2005
Fire Fighting › Fixed CO2 Fire Extinguishing System › Operating Controls
Issued 24 November 2004 Resolved
Install second fixed fire system override for other hull - systems must be independent.
Condition: Design Flaw
Action required: 705 - Other - as specified
Due 30 January 2005
Resolved 30 January 2005
Resolution: Deficiencies Found and Corrected
Pollution Prevention/Response › Prevention Equipment › Bilge Monitor
Issued 24 November 2004 Resolved
Prove proper operation of bilge pump alarms - (stbd aft) and install alarms in port and stbd center compartment.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 30 January 2005
Resolved 30 January 2005
Resolution: Inpected Satisfactory
Fire Fighting › Fire Bucket › Capacity
Issued 24 November 2004 Resolved
Provide 3 proper fire buckets.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 30 January 2005
Resolved 30 January 2005
Resolution: Inspected Satisfactory
Documentation › Logs/Records › Logbook/Record (unofficial)
Issued 24 November 2004 Resolved
Start and maintain lifesaving equip maintenance log.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 24 November 2004
Resolved 30 January 2005
Resolution: Inspected Satisfactory
Lifesaving › Launching Appliances › Release Mechanism
Issued 24 November 2004 Resolved
Replace hydro-static release for EPIRB.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 30 November 2004
Resolved 30 January 2005
Resolution: Inspected Satisfactory
Navigation › Collision/Grounding Avoidance › Navigation Lights
Issued 4 November 2003 Resolved
Starboard navigation light not operating properly. Light was fixed prior to end of inspection and tested SAT.
Condition: Unknown
Due 4 November 2003
Resolved 4 November 2003
Operations/Management › Drug and Alcohol Testing › Testing, Random
Issued 4 November 2003 Resolved
Company shall stop notifying employees 24 hour in advance to drug testing. Notified operations manager Michelle at [phone withheld].
Condition: Improper Installation
Due 4 November 2003
Resolved 4 November 2003
Engineering › Electric Propulsion System › Battery
Issued 4 November 2003 Resolved
Provide battery covers for batteries located in port and starboard engine spaces and generator space.
Condition: Unknown
Due 20 November 2003
Resolved 24 November 2004
Fire Fighting › Fixed Gas Fire Extinguishing System
Issued 6 November 2002 Resolved
Provide fixed fire extinguisher servicing report.
Condition: Unknown
Due 29 November 2002
Resolved 26 November 2002
Navigation › Piloting/Steering
Issued 6 November 2002 Resolved
Provide CG light list. LEGACY COMPONENT DESC: Coast Guard Light List
Condition: Unknown
Due 29 November 2002
Resolved 26 November 2002
Lifesaving › Hand Flares
Issued 6 November 2002 Resolved
Provide (1) orange day flare IAW 46CFR180.68. LEGACY COMPONENT DESC: Quantity
Condition: Unknown
Due 29 November 2002
Resolved 26 November 2002
Stability › Watertight Integrity
Issued 5 September 2002 Resolved
Install hinged dead covers per 46 CFR 179.350
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 5 October 2002
Resolved 4 November 2003
Fire Fighting › Ventilation Systems
Issued 7 May 2002 Resolved
Replace handle and prove proper operation of stbd engine room closure vent IAW 46CFR182.465(h). LEGACY COMPONENT DESC: Duct Hatches
Condition: Unknown
Due 21 May 2002
Resolved 25 June 2002
Fire Fighting › Ventilation Systems
Issued 17 April 2002 Resolved
Replace handle and prove proper operation of stbd engineroom vent closure. LEGACY COMPONENT DESC: closure
Condition: Improper/Lack of Maintenance
Due 21 May 2002
Resolved 18 June 2002
Lifesaving
Issued 6 November 2001 Resolved
Provide 2 CG approved adult life jackets IAW 46CFR180.71 NLT 13NOV01. Vessel restricted to carrying not more than 53 total adult persons until corrected.
Condition: Unknown
Due 13 November 2001
Resolved 28 January 2002
Resolution: CORRECTED.
Fire Fighting
Issued 6 November 2001 Resolved
Provide proof of NFPA servicing for port E/R and genset space fixed fire fighting systems IAW 46 CFR 176.810 NLT 13NOV01.
Condition: Unknown
Due 13 November 2001
Resolved 28 January 2002
Resolution: CORRECTED.
Documentation
Issued 6 November 2001 Resolved
Provide proof of FCC Radio Operator [name withheld] 46CFR184.502 NLT 6DEC01.
Condition: Unknown
Due 28 December 2001
Resolved 28 January 2002
Resolution: CORRECTED.
Electrical
Issued 14 September 2000 Resolved
PROVIDE EMERGENCY LIGHTING IAW 46CFR183.432 NO LATER THAN 01OCT00. VESSEL MAY NOT ALLOW PASSENGERS BELOW THE MAIN DECK WHEN OPERATING AT NIGHT UNTIL CORRECTED.
Condition: Unknown
Due 26 June 2001
Resolved 26 June 2001
Documentation
Issued 14 September 2000 Resolved
PROVIDE PROOF OF FCC RADIO OPERATOR'S PERMIT IAW 46CFR184.502 NLT 21SEP00.
Condition: Unknown
Due 26 June 2001
Resolved 26 June 2001
Documentation
Issued 14 September 2000 Resolved
PROVIDE ALL DOCUMENTS TO COMPLETE A COMPANY DRUG TEST AUDIT IAW 46CFR16 PRIOR TO CARRYING PASSENGERS, AND NLT 21SEP00.
Condition: Unknown
Due 26 June 2001
Resolved 26 June 2001
Documentation
Issued 14 September 2000 Resolved
PROVIDE PROOF THAT TRAINING HAS BEEN CONDUCTED AND LOGGED IAW 46CFR185.420 PRIOR TO CARRYING PASSENGERS AND NO LATER THAN 21SEP00.
Condition: Unknown
Due 26 June 2001
Resolved 26 June 2001

Casualty record · 1

13 February 2005Routine · role: Involved in a Marine Casualty · serious marine incident, as classified · 1 injured · activity 2302300
Each line is an incident investigation the Coast Guard recorded with this hull among the vessels involved, with the date and the classification the Coast Guard gave it, and the bridge, lock or dam the investigation names where it names one. Involvement is not fault. The investigation narrative is not published. Source: IIR, through 2026.

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.