MAURY USCG vessel records
← All vessels

JODY - 102

JODY - 102 is a 1957 tank barge. The Coast Guard has recorded 23 inspections since 1982, most recently in January 1999, along with 5 deficiencies.

Records from 1982 to 1999. Most recent: inspection, 22 January 1999.

Built
1957
Last inspected
22 January 1999
Documentation
Not in the documentation file of 10 August 2026
Controls
None recorded without a removal date

This record may be incomplete: the most recent inspection recorded for this vessel was 27 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Barge class in Maury's sources begin in 1972.

Inspection record

Last inspected 22 January 1999
…with no type recorded6
Operational controls None recorded without a removal date
Years with a record 14 calendar years (1982–1999)
Every line above is a count of records the US Coast Guard wrote, or a date it recorded. A blank resolution means none was recorded in this data; it does not establish that a deficiency is outstanding. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Identity

Flag
UNITED STATES
Maury page id
psix-54814

Documentation record

Tonnage as PSIX records it79 - Regulatory (Subpart C or D), Net Ton
79 - Regulatory (Subpart C or D), Gross Ton
This hull's Official Number is not in the NVDC file dated 10 August 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.
Vessel history report
Every record for this hull, in one document — $299

Every recorded inspection, 1972 to 2026 for this class, in one chronology · every deficiency, with system, dates and resolution · operational controls imposed and removed · every name this hull has been recorded under · the vessels it was inspected alongside, and when · how its record compares with hulls of similar age and size, as a fact about the population and never a judgement about this vessel.

Read one first, in full: a forty-year chronology · a hull that changed operators four times · the sparse case, shown as an example, not for sale.

This report is in development and is not for sale yet. There is no date, and nothing is charged. Leave an email and we will tell you when it exists, once.

Inspection history · 23

22 January 1999 Administrative
Administrative · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 788631
18 December 1998 Examination of Repairs
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1457590
8 November 1996 COI Inspection
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1354025
17 January 1996 Examination of Repairs · Hull Examination · Deficiency Check
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1463931
19 December 1995 Re-Inspection
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1377578
18 May 1995 Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 758083
5 May 1995 Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 201097
10 November 1994 COI Inspection
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1429969
10 January 1994 Deficiency Check
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1169345
27 October 1993 Hull Examination · Re-Inspection
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1362869
17 November 1992 COI Inspection
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1135773
14 November 1991 Re-Inspection
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 934704
15 November 1990 COI Inspection · Hull Examination
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1214335
23 June 1987 Administrative
Administrative · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1006182
30 April 1987 Administrative
Administrative · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1333064
23 April 1986 Deficiency Check
Physical examination · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1310938
17 March 1986 Re-Inspection
Physical examination · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1016240
17 March 1986 Re-Inspection
Physical examination · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1021284
16 March 1986 Re-Inspection
Physical examination · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1021119
10 April 1985 Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1287534
27 March 1985 Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 982690
28 March 1983 Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 967803
30 June 1982 Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 967852

Deficiency record · 5

Construction/Loadline
Issued 19 December 1995 Resolved
Vessel is not authorized to carry cargo until the drydock, internal structural exam and cargo tank internal exam have been accomplished to attending inspector's satisfaction.
Condition: Unknown
Due 19 December 1995
Resolved 19 December 1995
Documentation
Issued 19 December 1995 Resolved
Post Oil Transfer Procedures on vessel.
Condition: Unknown
Due 19 December 1995
Resolved 19 December 1995
Deck/Cargo
Issued 19 December 1995 Resolved
Hydrostatic test cargo pump discharge/hose assemblies/pressure gage to 1.5 times MAWP.
Condition: Unknown
Due 19 December 1995
Resolved 19 December 1995
Documentation
Issued 19 December 1995 Resolved
Provide documentation that stability information for vessel is available inaccordance with 33 CFR 155.245.
Condition: Unknown
Due 19 December 1995
Resolved 19 December 1995
Construction/Loadline
Issued 10 November 1994 Resolved
CROP AND RENEW AS ORIGINAL WASTED BOTTOM LONGITUDINALS IN STERN VOID.
Condition: Unknown
Due 10 November 1994
Resolved 10 November 1994

Ownership record