Records from 1983 to 2025. Most recent: inspection, 11 December 2025.
Documentation record
Registered dimensions (L × B × D)66.4 ft × 24.0 ft × 10.2 ft
Registered tonnagegross 170 / net 115
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderF B WALKER & SONS INC · PASCAGOULA, MS, UNITED STATES · built 1977
Hull materialSteel
PropulsionDiesel
Hull shapeNot recorded
Hull configurationNot recorded
Hailing portEAST DUBUQUE, IL
Trade endorsementsCoastwise, unrestricted
DocumentationValid · issued 14 May 2026 · expires 30 June 2027
Service, as the file records itTowing Vessel
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it115 - Regulatory (Subpart C or D), Net Ton
170 - Regulatory (Subpart C or D), Gross Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 September 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
Inspection history · 29
11 December 2025
Annual Inspection
Physical examination · Marine Safety Detachment Quad Cities · USCG Heartland District (CGD-H) · Activity 8287400
27 March 2025
Administrative Inspection · Damage Survey
Physical examination · Marine Safety Detachment Quad Cities · USCG Heartland District (CGD-H) · Activity 8101527
18 November 2024
Administrative Inspection · Annual Inspection
Physical examination · Marine Safety Detachment Quad Cities · USCG Heartland District (CGD-H) · Activity 8036606
15 November 2023
Annual Inspection
Physical examination · Marine Safety Detachment Quad Cities · USCG Heartland District (CGD-H) · Activity 7825290
1 March 2023
Bulk Liquid Transfer Monitor
Physical examination · Marine Safety Detachment Quad Cities · USCG Heartland District (CGD-H) · Activity 7644082
16 November 2022
Initial Certification · DAPI Audit
Physical examination · Marine Safety Detachment Quad Cities · USCG Heartland District (CGD-H) · Activity 7595752
18 February 2020
Administrative Inspection
Administrative · Marine Safety Detachment Quad Cities · USCG Heartland District (CGD-H) · Activity 6913099
18 August 2010
Industry Initiated Exam · MTSA Verification
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 3828274
6 June 2006
Security Plan Amendment Review - ASP
Administrative · Marine Safety Center (MSC) · Activity 2671940
9 June 2005
MTSA Verification
Physical examination · MSO Paducah · USCG Heartland District (CGD-H) · Activity 2385298
18 October 2004
Administrative Inspection
Administrative · Marine Safety Center (MSC) · Activity 2223277
23 December 2003
Security Plan Review - ASP
Administrative · Marine Safety Center (MSC) · Activity 1984299
7 June 2000
Type not recorded
No type recorded · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 223477
3 May 2000
Type not recorded
No type recorded · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 224315
18 June 1999
Type not recorded
No type recorded · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 173735
12 October 1998
Type not recorded
No type recorded · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 97064
12 October 1998
Type not recorded
No type recorded · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 223724
26 March 1997
Type not recorded
No type recorded · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 690979
22 February 1997
Type not recorded
No type recorded · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 48551
22 February 1997
Type not recorded
No type recorded · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 401447
4 November 1996
Type not recorded
No type recorded · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 149463
2 March 1996
Type not recorded
No type recorded · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 181543
22 January 1996
Type not recorded
No type recorded · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 14501
22 January 1996
Type not recorded
No type recorded · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 224011
12 May 1995
Type not recorded
No type recorded · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 378649
10 June 1994
Type not recorded
No type recorded · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 690976
5 March 1992
Type not recorded
No type recorded · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 188069
29 March 1983
Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 966542
29 March 1983
Administrative
Administrative · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1336907
10 - Safety of Navigation › N/A - No Subsystem › Bridge Navigation Watch Alarm System (BNWAS)
Issued 11 December 2025
Resolved
A towing vessel with overnight accommodations and alternating watches (shift work), when pulling, pushing or hauling alongside one or more barges, must have a system to detect when its master or mate (pilot) becomes incapacitated. Vessel does not have a pilothouse alerter system installed. 46 CFR 143.450(a)
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 1 April 2026
Resolved 29 May 2026
Resolution: System installed satisfactorily.
07 - Fire Safety › N/A - No Subsystem › Oil accumulation in engine room
Issued 18 November 2024
Resolved
Fueling station on port main deck has sitting which is dripping into engine room overheads. Clean out sitting fuel and re-weld connection.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 2 December 2024
Resolved 14 February 2025
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 18 November 2024
Resolved
Port side fueling station fill pipe in engine room has leaking flange. Renew/tighten flange. All seals and gaskets must be properly maintained to prevent leaks of flammable or combustible liquid, as those terms are defined in 46 CFR subpart 30.10, into the machinery space.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 2 December 2024
Resolved 2 January 2025
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 18 November 2024
Resolved
Steering system hard lines go to flex hose/ram were not secure and were rubbing on the deck. Machinery and electrical systems must be designed and maintained to provide for safe operation of the towing vessel and safety of persons onboard under normal and emergency conditions.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 2 December 2024
Resolved 14 February 2025
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 18 November 2024
Resolved
Electrical panel located in forward engine room missing blanks. Electrical systems and equipment must function properly and minimize system failures and fire and shock hazards.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 2 December 2024
Resolved 6 January 2025
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 16 November 2022
Resolved
The operator of a vessel with a capacity of 250 or more barrels of oil, hazardous material, or liquefied gas as regulated in Table 4 of 46 CFR part 154 shall provide transfer procedures that meet the requirements of this part and part 156 of this chapter for transferring -
Action required: 16 - Rectify deficiencies w/in 14 days
Due 13 December 2022
Resolved 30 November 2022
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 16 November 2022
Resolved
Pressure relief valves must be marked with relief pressure and date of install or last test.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 29 December 2022
Resolved 30 November 2022
Lifesaving
Issued 22 February 1997
Resolved
Operator did not have Coast Guard approved PFD's onboard the vessel.
Condition: Unknown
Due 22 February 1997
Resolved 18 May 2002
Resolution: MISLE Maintenance - Resolved all open deficiencies issued prior to 6/1/1997 where activity was closed and deficiency due date was past