Records from 1985 to 1993. Most recent: inspection, 15 June 1993.
A report is not offered for this hull: Its record holds only 2 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. Reports.
Inspection history · 10
15 June 1993
Administrative
Administrative · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1132959
5 January 1990
Type not recorded
No type recorded · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 911725
9 September 1989
Administrative
Administrative · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1203419
2 August 1988
Type not recorded
No type recorded · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1341451
7 August 1987
Excursion Permit
Administrative · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1028787
15 July 1987
Deficiency Check
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1019476
25 May 1987
Re-Inspection
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1027320
5 April 1986
COI Inspection
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1001497
8 December 1985
Examination of Repairs · Credit Drydock
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 988134
23 June 1985
Type not recorded
No type recorded · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1288766
Electrical
Issued 25 May 1987
Resolved
SUBMIT ELECTRICAL PLANS ON SHORE TIE HOOK UP RECEPTICALS.
Condition: Unknown
Due 25 May 1987
Resolved 25 May 1987
Engineering
Issued 25 May 1987
Resolved
RENEW P/S FUEL TANK VENT TUBING.
Condition: Unknown
Due 25 May 1987
Resolved 25 May 1987
Engineering
Issued 25 May 1987
Resolved
PROVIDE ADDITIONAL MEANS OF SUPPORT FOR BILGE SUCTION LINE ARR'T IN WAY OF AFTER LAZARETTE AND BELOW GALLEY DECK.
Condition: Unknown
Due 25 May 1987
Resolved 25 May 1987
Accommodation/Occupational Safety
Issued 25 May 1987
Resolved
PROVIDE MEANS TO PROPERLY SUPPORT ACCESS LADDER TO GALLEY COMPARTMENT.
Condition: Unknown
Due 25 May 1987
Resolved 25 May 1987
Lifesaving
Issued 25 May 1987
Resolved
RENEW GRABLINES ON 15 MAN LIFEFLOAT.
Condition: Unknown
Due 25 May 1987
Resolved 25 May 1987
Electrical
Issued 25 May 1987
Resolved
PROVIDE JUNCTION BOX FOR MAIN MAST LIGHT WIREING SYSTEM.
Condition: Unknown
Due 25 May 1987
Resolved 25 May 1987
Construction/Loadline
Issued 25 May 1987
Resolved
PROVIDE INCREASED SUPPORT TO VESSELS SAFETY RAIL STANCHIONS ON MAIN DECK. THESE INCLUDE THE FIRST FOUR STANCHIONS ON BOTH PORT AND STARBOARD SIDE.
Condition: Unknown
Due 25 May 1987
Resolved 25 May 1987
Construction/Loadline
Issued 8 December 1985
Resolved
REPAIR ROTTEN PLANK AMIDSHIP STBD EIGHTH PLANK FROM KEEL,10 FEEET FWD OF STBD SHAFT LOG.
Condition: Unknown
Due 8 December 1985
Resolved 8 December 1985
Construction/Loadline
Issued 8 December 1985
Resolved
REPAIR ROTTEN PLANK ALONG L CLAMP.
Condition: Unknown
Due 8 December 1985
Resolved 8 December 1985
Construction/Loadline
Issued 8 December 1985
Resolved
REPAIR ROTTEN PLANK PORT SIDE ALONG GROUND PLATE
Condition: Unknown
Due 8 December 1985
Resolved 8 December 1985
Construction/Loadline
Issued 8 December 1985
Resolved
SUBMIT A PROPOSAL FOR THE FOLLOWING ITEMS FOUND IN DRYDOCK INSPECTION: (A) REPAIRS TO FRAMES IN FORWARD HEAD, CABIN, AND BERTHING UNDER CHART ROOM(B) REPAIRS TO PORT STERN CORNER POST.
Condition: Unknown
Due 8 December 1985
Resolved 8 December 1985
Construction/Loadline
Issued 8 December 1985
Resolved
REPAIR ROTTEN PLANK STBD FWD OF FIRST THROUGH HULL 4"X1"
Condition: Unknown
Due 8 December 1985
Resolved 8 December 1985
Lifesaving
Issued 23 June 1985
Resolved
PROVIDE 23 ADDITIONAL ADULT AND 7 CHILD LIFE PRESERVERS. VSL IS NOT TO OPERATE WITH MORE THAN 30 PERSONS ON BOARD UNTIL ABOVE PFD'S ARE ON BOARD.
Condition: Unknown
Due 23 June 1985
Resolved 23 June 1985
Accommodation/Occupational Safety
Issued 23 June 1985
Resolved
PERMANANTLY INSTALL COMPANIONWAY LADDER INTO THE AFT CABIN INCLUDING A HANDRAIL.
Condition: Unknown
Due 23 June 1985
Resolved 23 June 1985
Electrical
Issued 23 June 1985
Resolved
INSTALL A BELT GUARD ON THE 110/220 VOLT GENERATOR.
Condition: Unknown
Due 23 June 1985
Resolved 23 June 1985