Records from 1984 to 1995. Most recent: inspection, 31 July 1995.
A report is not offered for this hull: Its record holds only 2 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. Reports.
Inspection history · 38
31 July 1995
Administrative
Administrative · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 873577
4 November 1994
Plan Review "T" Boat
Administrative · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 868409
24 August 1994
Administrative
Administrative · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1173901
19 July 1994
Deficiency Check · COI Inspection
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1171782
20 May 1994
Hull Examination
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1435491
14 December 1993
Deficiency Check
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 850065
15 July 1993
COI Inspection
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 846474
3 February 1993
Deficiency Check
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 827291
27 November 1992
Hull Examination · Deficiency Check
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 832745
2 October 1992
Deficiency Check
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1246001
22 July 1992
COI Inspection
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 951940
17 April 1992
Administrative
Administrative · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1269256
8 October 1991
Deficiency Check
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1251791
31 July 1991
COI Inspection
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1245806
18 June 1991
Hull Examination
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1199406
20 May 1991
Administrative
Administrative · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 916719
17 October 1990
Deficiency Check
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 900113
6 August 1990
COI Inspection
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 921173
24 July 1990
Deficiency Check
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1230560
30 June 1990
Type not recorded
No type recorded · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 926235
18 April 1990
Type not recorded
No type recorded · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 929316
15 February 1990
Deficiency Check
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 927793
2 February 1990
Administrative
Administrative · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 931486
5 January 1990
Deficiency Check
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1240892
27 November 1989
Hull Examination
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 929894
23 August 1989
COI Inspection · Deficiency Check
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1208101
24 July 1989
Type not recorded
No type recorded · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 889268
5 June 1989
Type not recorded
No type recorded · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1204686
23 November 1988
Hull Examination
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1035856
22 August 1988
Deficiency Check
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1346874
27 May 1988
Deficiency Check · COI Inspection
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1196605
27 November 1987
Hull Examination
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1312391
16 June 1987
Type not recorded
No type recorded · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1312228
9 June 1987
Administrative
Administrative · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1028550
31 December 1986
Administrative
Administrative · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1310296
29 June 1985
Deficiency Check
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1299476
16 April 1985
Type not recorded
No type recorded · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1290099
23 November 1984
Type not recorded
No type recorded · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 976582
Documentation
Issued 19 July 1994
Resolved
PROVIDE PROOF OF COMPLIANCE WITH DRUG TESTING PROGRAM PRIOR TO SAILING
Condition: Unknown
Due 18 August 1994
Resolved 18 October 1994
Lifesaving
Issued 19 July 1994
Resolved
PROVIDE AND POST EMERGENCY CHECKOFF LIST PRIOR TO SAILING.
Condition: Unknown
Due 18 August 1994
Resolved 18 October 1994
Lifesaving
Issued 19 July 1994
Resolved
PROVIDE INDICATOR LIGHT FOR QAWTD IN AFT BERTHING
Condition: Unknown
Due 18 August 1994
Resolved 18 October 1994
Construction/Loadline
Issued 19 July 1994
Resolved
MAKE WATERTIGHT MAIN DECK OVER CREWS BERTHING, STBD SIDE
Condition: Unknown
Due 18 August 1994
Resolved 18 October 1994
Construction/Loadline
Issued 19 July 1994
Resolved
PROVE WATERTIGHTNESS OF MAIN DECK ABOVE LAZARETTE IN FOLLOWING AREAS: (A) PORT SIDE, APPROX. 6 IN. INBOARD OF HULL & DECK JOINT, BETWEEN 4TH & 5TH FRAMES FROM AFT (B) STBD SIDE, IWO BULWARKS 4TH FRAME FROM AFT UP TO THE FORWARD WATERTIGHT BULKHEAD. ISSUE DATE: 18OCT94
Condition: Unknown
Due 18 November 1994
Resolved 18 May 2002
Resolution: MISLE Maintenance - Resolved all open deficiencies issued prior to 6/1/1997 where activity was closed and deficiency due date was past
Lifesaving
Issued 19 July 1994
Resolved
PROVIDE BATTERIES AND PROVE OPERATION OF STBD B/A WATERLIGHT PRIOR TO SAILING
Condition: Unknown
Due 18 August 1994
Resolved 18 October 1994
Lifesaving
Issued 19 July 1994
Resolved
SECURE ONE SIDE OF B/A SEAPAINTER WEAK LINK TO THE VESSEL PRIOR TO SAILING
Condition: Unknown
Due 18 August 1994
Resolved 18 October 1994
Lifesaving
Issued 19 July 1994
Resolved
PROVIDE FOUR ADDITIONAL PENDANTS PROPERLY MADE UP INTO HANKS FOR EACH B/A PRIOR TO SAILING
Condition: Unknown
Due 18 August 1994
Resolved 18 October 1994
Engineering
Issued 19 July 1994
Resolved
PROVIDE LABEL FOR EMERGENCY FUEL SHUTOFF VALVES ON OUTSIDE OF DOOR IN SPACEAFT OF PILOT HOUSE
Condition: Unknown
Due 18 August 1994
Resolved 18 October 1994
Accommodation/Occupational Safety
Issued 19 July 1994
Resolved
REMOVE "GAS" LABEL FROM FRESH WATER FILL, STBD SIDE
Condition: Unknown
Due 18 August 1994
Resolved 18 October 1994
Construction/Loadline
Issued 19 July 1994
Resolved
MAKE WATERTIGHT HULL AND DECK JOINT, CREWS BERTHING, PORTSIDE, BETWEEN 4TH AND 5TH FRAME FROM AFT
Condition: Unknown
Due 18 August 1994
Resolved 18 October 1994
Electrical
Issued 19 July 1994
Resolved
PROVIDE EMERGENCY LIGHTING SYSTEM, AUTOMATICALLY ACTUATED IN THE EVENT OF POWER FAILURE
Condition: Unknown
Due 25 November 1994
Resolved 18 May 2002
Resolution: MISLE Maintenance - Resolved all open deficiencies issued prior to 6/1/1997 where activity was closed and deficiency due date was past
Construction/Loadline
Issued 20 May 1994
Resolved
PROVIDE A WRITTEN STATEMENT TO [name withheld] ATTESTING TO PROPER OPERATION OF PROPULSION, STEERING AND BILGE PUMPING SYSTEMS AS WELL AS LACKOF EXCESSIVE LEAKAGE BELOW THE WATERLINE FOLLOWING VESSEL'S POST-DRYDOCKINGRETURN TO THE WATER.
Condition: Unknown
Due 8 June 1994
Resolved 12 July 1994
Construction/Loadline
Issued 20 May 1994
Resolved
TREAT AND FILL SMALL WORM DAMAGED AREAS OF KEEL SHOE AT BUTTS OF SHOE JOINTS.
Condition: Unknown
Due 24 May 1994
Resolved 2 June 1994
Construction/Loadline
Issued 20 May 1994
Resolved
SISTER OR REPLACE FIRST FRAME STARBOARD SIDE IN FOREPEAK DUE TO EXTENSIVE WET ROT ON FRAME HEAD.
Condition: Unknown
Due 20 June 1994
Resolved 10 August 1994
Construction/Loadline
Issued 20 May 1994
Resolved
RESTRICT OPERATION OF THE VESSEL TO A LAKE, BAYS & SOUNDS ROUTE UNTIL SUCH TIME AS THE FOLLOWING CRACKED FRAMES ARE SISTERED OR REPLACED: AFT BERTHINGPORTSIDE - 3RD & 6TH FRAMES FROM FWD BULKHEAD/STBDSIDE - 1ST & 3RD FRAMES._x001C_MID-BERTHING STBDSIDE - 1ST, 3DR, 7TH & 8TH FRAMES FROM FWD BULKHEAD. CONT'
Condition: Unknown
Due 20 May 1995
Resolved 18 May 2002
Resolution: MISLE Maintenance - Resolved all open deficiencies issued prior to 6/1/1997 where activity was closed and deficiency due date was past
Construction/Loadline
Issued 20 May 1994
Resolved
DETERMINE SOURCE OF DECK LEAK ABOVE FIRST FRAME STARBOARD SIDE AND MAKE SUITABLE RESTORATION OF WATERTIGHTNESS.
Condition: Unknown
Due 20 June 1994
Resolved 10 August 1994
Electrical
Issued 15 July 1993
Resolved
CONDUCT OPERATIONAL TEST ON PORT GENERATOR. INDUCTOR HAS BEEN REPLACED. (PRIOR TO REPAIR SHEEN WOULD OCCUR).
Condition: Unknown
Due 15 July 1993
Resolved 15 July 1993
Construction/Loadline
Issued 27 November 1992
Resolved
PROPERLY FASTEN STARBOARD SECTION OF HANDRAIL WHERE LOOSE.
Condition: Unknown
Due 27 November 1992
Resolved 27 November 1992
Construction/Loadline
Issued 27 November 1992
Resolved
REMOVE AFT THREE FEET OF WORMSHOE AND REPLACE AS PER ORIGINAL. (WHERE PREVIOUSLY COVERED WITH LEAD) ITEM TO BE INSPECTED PRIOR TO GOING BACK IN WATER.
Condition: Unknown
Due 1 December 1992
Resolved 1 December 1992
Construction/Loadline
Issued 27 November 1992
Resolved
PROPERLY FASTEN FWD STBD SECTION OF BULWARK WHERE LOOSE.
Condition: Unknown
Due 27 November 1992
Resolved 27 November 1992
Lifesaving
Issued 22 July 1992
Resolved
PROVIDE TWO ADDITIONAL ADULT PFDs. VESSEL IS RESTRICTED TO CARRYING 51 ADULTS UNTIL CLEARED.
Condition: Unknown
Due 22 July 1992
Resolved 22 July 1992
Lifesaving
Issued 22 July 1992
Resolved
PROPERLY LABEL CHILDREN'S PFD STORAGE COMPARTMENT TO READ "6 CHILDREN'S LIFE PRESERVERS."
Condition: Unknown
Due 22 July 1992
Resolved 22 July 1992
Fire Fighting
Issued 22 July 1992
Resolved
PROVIDE A SPANNER WRENCH FOR EACH FIRE STATION.
Condition: Unknown
Due 22 July 1992
Resolved 22 July 1992
Construction/Loadline
Issued 22 July 1992
Resolved
REPAIR WOOD FRAME MOUNTING TO AFT HATCH IN THE VESSEL'S LAZARETTE.
Condition: Unknown
Due 22 July 1992
Resolved 22 July 1992
Accommodation/Occupational Safety
Issued 18 June 1991
Resolved
HYDROSTATICALLY TEST AIR RECEIVER/PRESSURE VESSEL AT 1 1/4 TIMES MAXIMUM ALLOWABLE WORKING PRESSURE.
Condition: Unknown
Due 18 June 1991
Resolved 18 June 1991
Navigation
Issued 17 October 1990
Resolved
DURING NEXT INSPECTION BUT NO LATER THAN 06AUG91 PRESSURE VESSEL MUST BE EITHER INTERNALLY EXAMINED OR HYDROSTATICALLY TESTED TO THE SATISFACTION OFTHE ATTENDING INSPECTOR.
Condition: Unknown
Due 17 October 1990
Resolved 17 October 1990
Fire Fighting
Issued 6 August 1990
Resolved
VESSEL MUST PROVIDE ONE ADDITIONAL BII FIRE EXTINGUISHER IN THE LIVING SPACES.
Condition: Unknown
Due 6 August 1990
Resolved 6 August 1990
Construction/Loadline
Issued 6 August 1990
Resolved
VESSEL MUST INSTALL SECURING DEVICE FOR THE FORWARD HATCH.
Condition: Unknown
Due 6 August 1990
Resolved 6 August 1990
Fire Fighting
Issued 6 August 1990
Resolved
VESSEL MUST PROVIDE SUCTION HOSE AND DISCHARGE HOSE FOR THE PORTABLE HAND FIRE PUMP. THE SUCTION HOSE SHALL BE OF A LENGTH TO REACH THE WATER LINE FROM THE MAIN DECK. THE DISCHARGE HOSE SHALL BE OF A LENGTH FOR EFFECTIVE FIRE FIGHTING.
Condition: Unknown
Due 6 August 1990
Resolved 6 August 1990
Construction/Loadline
Issued 6 August 1990
Resolved
VESSEL MUST LABEL BOTH INTERIOR AND EXTERIOR OF ESCAPE HATCHES FROM ENGINE ROOM.
Condition: Unknown
Due 6 August 1990
Resolved 6 August 1990
Lifesaving
Issued 6 August 1990
Resolved
VESSEL MUST PROVIDE 14 REPLACEMENT ADULT PFD'S TO REPLACE THOSE REJECTED. REJECTED 11 DUE TO NORMAL WEAR, 4 AS THEY WERE NOT USCG APPROVED. VESSEL RESTRICTED TO 39 PASSENGERS UNTIL THIS REQUIREMENT IS MET.
Condition: Unknown
Due 6 August 1990
Resolved 6 August 1990
Navigation
Issued 30 June 1990
Resolved
PROVIDE FCC RADIOTELEPHONY CERTIFICATE.
Condition: Unknown
Due 30 June 1990
Resolved 30 June 1990
Accommodation/Occupational Safety
Issued 23 August 1989
Resolved
6 COMPLETE INSTALLATION OF AFT TOILET.
Condition: Unknown
Due 23 August 1989
Resolved 23 August 1989
Accommodation/Occupational Safety
Issued 23 August 1989
Resolved
8 MODIFY ESCAPE HATCHES PER APPROVED PLAN.
Condition: Unknown
Due 23 August 1989
Resolved 23 August 1989
Fire Fighting
Issued 23 August 1989
Resolved
2 INSTALL ONE ADDITIONAL FIRE HYDRANT TO PROVIDE A TOTAL OF 2.
Condition: Unknown
Due 23 August 1989
Resolved 23 August 1989
Fire Fighting
Issued 23 August 1989
Resolved
3 PROVIDE LINED FIRE HOSE AS PER 46CFR181.15-10.
Condition: Unknown
Due 23 August 1989
Resolved 23 August 1989
Engineering
Issued 23 August 1989
Resolved
4 PROVIDE BILGE PIPING TO LAZARETTE PER 46CFR182.25.
Condition: Unknown
Due 23 August 1989
Resolved 23 August 1989
Construction/Loadline
Issued 23 August 1989
Resolved
5 CAP THE THROUGH HULL FITTING ON THE PORT SIDE OF ENGINE ROOM.
Condition: Unknown
Due 23 August 1989
Resolved 23 August 1989
Documentation
Issued 23 August 1989
Resolved
1 PROVIDE AND POST PERMANENT STABILITY LETTER.
Condition: Unknown
Due 23 August 1989
Resolved 23 August 1989
Fire Fighting
Issued 27 May 1988
Resolved
SERVICE ALL FIRE EXTINGUISHERS.
Condition: Unknown
Due 27 May 1988
Resolved 27 May 1988
Engineering
Issued 27 May 1988
Resolved
REPAIR OIL PRESSURE GAGE IN PILOTHOUSE FOR PORT ENGINE.
Condition: Unknown
Due 27 May 1988
Resolved 27 May 1988
Electrical
Issued 27 May 1988
Resolved
CONDUCT OPERATIONAL TEST OF GENERATOR.
Condition: Unknown
Due 27 May 1988
Resolved 27 May 1988
Construction/Loadline
Issued 27 May 1988
Resolved
REPLACE DRY ROTTED SHEER CLAMP AGAINST TRANSOM.
Condition: Unknown
Due 27 May 1988
Resolved 27 May 1988
Construction/Loadline
Issued 27 May 1988
Resolved
REPLACE 4 BROKEN RIBS IN WAY OF E/R PORT SIDE AND PORT & STBD BERTHING AFT OF E/R.
Condition: Unknown
Due 27 May 1988
Resolved 27 May 1988
Lifesaving
Issued 27 May 1988
Resolved
PROVIDE 9 ADULT AND 4 CHILD PFD'S TO BRING TOTAL ONBOARD TO 53 ADULT AND 6 CHILD.
Condition: Unknown
Due 27 May 1988
Resolved 27 May 1988
Construction/Loadline
Issued 27 May 1988
Resolved
TREAT AND COAT HULL SCRAPE FWD STBD SIDE.
Condition: Unknown
Due 27 May 1988
Resolved 27 May 1988
Lifesaving
Issued 27 May 1988
Resolved
INSTALL PENDANTS ON BUOYANT APPARATUS.
Condition: Unknown
Due 27 May 1988
Resolved 27 May 1988
Lifesaving
Issued 27 May 1988
Resolved
ATTACH THE TWO BUOYANT APPARATUS TOGETHER.
Condition: Unknown
Due 27 May 1988
Resolved 27 May 1988
Engineering
Issued 27 May 1988
Resolved
REPLACE FLAME SCREENS ON FUEL TANK VENTS.
Condition: Unknown
Due 27 May 1988
Resolved 27 May 1988
Fire Fighting
Issued 27 May 1988
Resolved
INSTALL AND TEST FIRE PUMP WITH 2 HYDRANTS,50' X 1 1/2 " HOSE AT EACH HYDRANT.
Condition: Unknown
Due 27 May 1988
Resolved 27 May 1988
Lifesaving
Issued 27 May 1988
Resolved
INSTALL PROPER SIZE WEAK LINK FOR BUOYANT APPARATUS.
Condition: Unknown
Due 27 May 1988
Resolved 27 May 1988
Engineering
Issued 27 May 1988
Resolved
REPLACE PLASTIC BILGE PIPING IN E/R WITH METALLIC PIPING.
Condition: Unknown
Due 27 May 1988
Resolved 27 May 1988
Construction/Loadline
Issued 27 May 1988
Resolved
INSTALL PROPER BKHD PENETRATION AS PER 46CFR182.40 FOR PLASTIC MSD PIPING PENETRATING AFT BKHD OF E/R.
Condition: Unknown
Due 27 May 1988
Resolved 27 May 1988
Construction/Loadline
Issued 27 November 1987
Resolved
REPLACE IN-KIND FOUR BROKEN RIBS IN WAY OF E/R PORT SIDE, AND P/S BERTHING AFT OF E/R.
Condition: Unknown
Due 27 November 1987
Resolved 27 November 1987
Construction/Loadline
Issued 27 November 1987
Resolved
TREAT AND COAT HULL SCRAPE ON FWD STBD SIDE OF EXTERIOR HULL.
Condition: Unknown
Due 27 November 1987
Resolved 27 November 1987
Construction/Loadline
Issued 27 November 1987
Resolved
REPLACE IN-KIND THE AFT PORT DECK, SHEER CLAMP, AND GUSSET WHICH IS DRY ROTTED.
Condition: Unknown
Due 27 November 1987
Resolved 27 November 1987
Engineering
Issued 16 April 1985
Resolved
REMOVE SIGHT GLASS ON STARBOARD FUEL OIL TANK.
Condition: Unknown
Due 16 April 1985
Resolved 16 April 1985
Documentation
Issued 16 April 1985
Resolved
CONDUCT A STABILITY TEST OR REQUEST AN EXEMPTION IN WRITING.
Condition: Unknown
Due 16 April 1985
Resolved 16 April 1985
Lifesaving
Issued 16 April 1985
Resolved
PROVIDE 8 ADULT PFD'S.
Condition: Unknown
Due 16 April 1985
Resolved 16 April 1985
Engineering
Issued 16 April 1985
Resolved
INSTALL EMERGENCY FUEL SHUTOFFS.
Condition: Unknown
Due 16 April 1985
Resolved 16 April 1985