MAURY USCG vessel records
← All vessels

DIXIE BELLE

DIXIE BELLE is a 1983 passenger vessel (inspected). The Coast Guard has recorded 10 inspections since 2019, most recently in April 2026, along with 29 deficiencies and 1 casualty investigation in 2010.

Records from 2010 to 2026. Most recent: inspection, 16 April 2026.

Built
1983
Last inspected
16 April 2026
Documentation
Expired · documentation file of 10 August 2026
Controls
None recorded without a removal date

Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 2016.

Inspection record

Last inspected 16 April 2026
Operational controls None recorded without a removal date
Years with a record 7 calendar years (2019–2026)
Every line above is a count of records the US Coast Guard wrote, or a date it recorded. A blank resolution means none was recorded in this data; it does not establish that a deficiency is outstanding. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Identity

Flag
UNITED STATES
Maury page id
psix-54829

Documentation record

Registered dimensions (L × B × D)51.5 ft × 20.0 ft × 4.5 ft
Registered tonnagegross 68 / net 68
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderR R & R A REYNOLDS INC · LONG BEACH, CA, UNITED STATES · built 1983
Hull materialSteel
PropulsionGasoline Outboard
Hull shapeShip
Hull configurationMonohull
Hailing portLAKE HAVASU CITY, AZ
Trade endorsementsCoastwise, unrestricted
DocumentationExpired · issued 30 June 2004
Service, as the file records itPassenger (Inspected)
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it68 - Simplified, Gross Ton
68 - Simplified, Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 August 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
Vessel history report
Every record for this hull, in one document — $299

Every recorded inspection, 2016 to 2026 for this class, in one chronology · every deficiency, with system, dates and resolution · operational controls imposed and removed · every name this hull has been recorded under · the vessels it was inspected alongside, and when · how its record compares with hulls of similar age and size, as a fact about the population and never a judgement about this vessel.

Read one first, in full: a forty-year chronology · a hull that changed operators four times · the sparse case, shown as an example, not for sale.

This report is in development and is not for sale yet. There is no date, and nothing is charged. Leave an email and we will tell you when it exists, once.

Inspection history · 10

16 April 2026 Drydock Exam · Internal Structural Exam · Deficiency Check
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 8350029
7 January 2026 COI Inspection
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 8283979
6 January 2025 Annual Inspection
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 8050984
16 January 2024 Annual Inspection
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 7860004
22 May 2023 In-Service Inspection
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 7701007
7 September 2022 Annual Inspection · Administrative Inspection
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 7542602
26 October 2021 DAPI Audit · Initial Certification · Deficiency Check · COI Inspection
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 7335736
1 September 2021 COI Inspection
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 7285040
15 June 2021 In-Service Inspection · Simplified Stability Test
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 7256437
8 July 2019 Construction Oversight
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 6766791

Deficiency record · 29

11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 7 January 2026 Resolved
A vessel must have one or more ring life buoys. Marine Inspector found the ring life buoy's line no longer serviceable. 46 CFR 180.70 (a)
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 21 January 2026
Resolved 26 February 2026
Resolution: Vessel added new life ring
11 - Life Saving Appliances › N/A - No Subsystem › Distress flares
Issued 7 January 2026 Resolved
Distress signals: Lakes, bays, and sounds, and rivers routes. A vessel on a lakes, bays, and sounds, or rivers route must carry: Three hand red flare distress signals approved in accordance with § 160.021 in subchapter Q of this chapter and three hand orange smoke distress signals approved in accordance with § 160.037 in subchapter Q of this chapter Marine Inspector found two expired hand flares. 46 CFR 180.68 (b)(1)(2)
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 21 January 2026
Resolved 26 February 2026
Resolution: Vessel has correct amount of flares
09 - Working and Living Conditions › 092 - Working Conditions › Warning notices
Issued 7 January 2026 Resolved
On a vessel on which the number of passengers permitted on upper decks is limited by stability criteria, as indicated by the vessel's stability letter, the maximum number of passengers allowed on an upper deck must be indicated by a durable marking of at least 25 millimeters (1 inch) numbers and letters at the entrance to that deck. 46 CFR 185.602 (g)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 21 January 2026
Resolved 26 February 2026
Resolution: Vessel operator installed sign
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 7 January 2026 Resolved
Each child size life jacket must be stowed in a location that is appropriately marked and separated from adult life jackets so the child size life jackets are not mistaken for adult life jackets. Marine Inspector found child life jackets not separate from adult life jackets. 46 CFR 180.78 (a)(5)
Condition: Design Flaw
Action required: 16 - Rectify deficiencies w/in 14 days
Due 21 January 2026
Resolved 26 February 2026
Resolution: Operator seperated lifejackets
07 - Fire Safety › N/A - No Subsystem › Fire detection and alarm system
Issued 7 September 2022 Resolved
46 CFR 181.420(a)(2) - The fixed gas extinguishing system must be operable from outside the space. The safety pin was installed in the system, rendering the remote operation cable disabled. Fixed on the spot.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 7 September 2022
Resolution: Fixed on the spot
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 7 September 2022 Resolved
The water heater is not fitted with a nameplate, and operating specifications could not be found. Demonstrate compliance with 46 CFR 182.320(a) by submitting specifications showing that the water heater’s capacity and heat input are below 120 gallons and 200,000 BTU/hr and that it is listed under UL 174 or UL 1453.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 7 October 2022
Resolved 14 September 2022
Resolution: Owner provided manufacturer spec sheet showing capacity and heat input are below 120 gallons and 200,000 BTU/hr and that it is UL approved. [name withheld]
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 7 September 2022 Resolved
46 CFR 183.220 - Remove all power strips onboard that are not suitable for service in a marine environment to the satisfaction of the attending marine inspector.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 7 October 2022
Resolved 6 January 2025
Resolution: Power strips removed.
04 - Emergency Systems › N/A - No Subsystem › Emergency source of power - Emergency generator
Issued 7 September 2022 Resolved
46 CFR 183.310(a)(1)(i) - Demonstrate that the fire pump and bilge pump are operable from a secondary source of power.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 7 October 2022
Resolved 6 January 2025
Resolution: Fire pump and bilge pump operational.
04 - Emergency Systems › N/A - No Subsystem › Emergency fire pump and its pipes
Issued 7 September 2022 Resolved
46 CFR 181.300(e) - Troubleshoot and repair intermittent failures on bridge remote fire pump start switch
Action required: 50 - Rectify deficiencies w/in 30 days
Due 7 October 2022
Resolved 14 September 2022
Resolution: Relay was tightened, testing onboard from remote switch in the pilothouse was satisfactory. [name withheld]
10 - Safety of Navigation › N/A - No Subsystem › Lights, shapes, sound-signals
Issued 7 September 2022 Resolved
33 CFR 86.01 - Troubleshoot and repair intermittent failures on compressor powering the ship’s horn
Action required: 50 - Rectify deficiencies w/in 30 days
Due 7 October 2022
Resolved 6 January 2025
Resolution: Ships horn operational.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 7 September 2022 Resolved
46 CFR 185.604(f) - All containers which are designated for storage of PFDs must be labeled with the number and identification of the PFDs stowed inside. Containers for child-sized PFDs must be labeled accordingly and segregated.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 7 October 2022
Resolved 6 January 2025
Resolution: PFD' labeled and stored properly.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Machinery space openings
Issued 7 September 2022 Resolved
46 CFR 176.800(a) - Access to the aft machinery and water tank spaces is currently made with a strip of tape on the hatch cover. Modify the hatch cover to facilitate easy access.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 7 October 2022
Resolved 6 January 2025
Resolution: Hatch modified.
11 - Life Saving Appliances › N/A - No Subsystem › Operational readiness of lifesaving appliances
Issued 7 September 2022 Resolved
46 CFR 180.70(d) - Renew the battery in the ring buoy float light. Perform an operational test of the light to the satisfaction of the attending marine inspector.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 7 October 2022
Resolved 14 September 2022
Resolution: Battery installed and light working as designed - [name withheld]
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 7 September 2022 Resolved
46 CFR 183.354(b) - Modify the battery installation such that it is protected from falling objects
Action required: 50 - Rectify deficiencies w/in 30 days
Due 7 October 2022
Resolved 6 January 2025
Resolution: Batteries protected from falling objects.
07 - Fire Safety › N/A - No Subsystem › Fixed fire extinguishing installation
Issued 26 October 2021 Resolved
Pre-engineered fixed gas fire extinguishing system installed must be capable of manual actuation from outside the space in addition to automatic heat activation. Properly install manual pull cable and mark with directions to activate system.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 23 November 2021
Resolution: Received tech report from Arizona West Fire & Safety attesting to installation and testing of manual pull cable.
07 - Fire Safety › N/A - No Subsystem › Fixed fire extinguishing installation
Issued 26 October 2021 Resolved
Pre-engineered fixed gas fire extinguishing system installed must automatically shut down all power ventilation fans and engines that draw intake air from the space protected and be provided with a means to reset fans/engines. Properly install shutdown and reset devices for fans and generator. Provide 3rd party servicing report of proper operation.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 23 November 2021
Resolution: Received tech report from Arizona West Fire & Safety attesting to testing of pressure switch for generator and blower shutdown.
04 - Emergency Systems › N/A - No Subsystem › Water level indicator
Issued 26 October 2021 Resolved
An unmanned machinery space bilge subject to flooding from sea water piping within the space must be provided with a visual and audible alarm at the operating station to indicate high water level. Properly install an intrinsically safe bilge high water alarm in the generator space.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 23 November 2021
Resolution: Received picture and video of working bilge alarm.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 26 October 2021 Resolved
Provide 56 adult & 09 child Type I lifejackets. Pax count reduced to 79 adults & 05 children. Update 11/4 - all children lifejackets on board. Update 11/23 - 40 additional adult lifejackets on board. Update 12/13 - 16 additional adult lifejackets on board.
Action required: 705 - Other - as specified
Resolved 13 December 2021
Resolution: Spoke with POC. All lifejackets marked and on board. Picture added to vessel file.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 26 October 2021 Resolved
Add master to random drug testing program or shared agreement from other company's program.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 26 November 2021
Resolved 23 November 2021
Resolution: Received proof of new USCG Consortium, master's pre-employment testing and full active random testing pool
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 26 October 2021 Resolved
Mark both stairwells to upper deck "Max Passengers 54."
Action required: 50 - Rectify deficiencies w/in 30 days
Due 26 November 2021
Resolved 4 November 2021
Resolution: Recieved pictures of max passengers 54 at each stairwell.
10 - Safety of Navigation › N/A - No Subsystem › Magnetic compass
Issued 26 October 2021 Resolved
Install illuminated magnetic compass. Illumination required prior to nighttime/reduced visibility ops.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 26 November 2021
Resolved 4 November 2021
Resolution: Received picture of illuminated magnetic compass.
10 - Safety of Navigation › N/A - No Subsystem › Charts
Issued 26 October 2021 Resolved
Provide chart of Lake Havasu.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 26 November 2021
Resolved 23 November 2021
Resolution: Lake Havasu map provided.
11 - Life Saving Appliances › N/A - No Subsystem › Distress flares
Issued 26 October 2021 Resolved
Provide watertight case for/marked “Distress Signals.”
Action required: 50 - Rectify deficiencies w/in 30 days
Due 26 November 2021
Resolved 4 November 2021
Resolution: Received picture.
11 - Life Saving Appliances › N/A - No Subsystem › Other (life saving)
Issued 26 October 2021 Resolved
Renew blocks for rescue platform.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 26 November 2021
Resolved 4 November 2021
Resolution: Received picture of new blocks installed.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 26 October 2021 Resolved
Provide portable hand bilge pump with sufficient hose length. (5 Gallons per minute capacity)
Action required: 50 - Rectify deficiencies w/in 30 days
Due 26 November 2021
Resolved 23 November 2021
Resolution: Picture of hand pump and 25' hose provided.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 26 October 2021 Resolved
Make lip for battery box to prevent battery acid from leaking onto deck.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 26 November 2021
Resolved 29 November 2021
Resolution: Picture received.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 26 October 2021 Resolved
Add additional length (50’) of anchor line.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 26 November 2021
Resolved 4 November 2021
Resolution: Received picture.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Covers (hatchway-, portable-, tarpaulins, etc.)
Issued 26 October 2021 Resolved
Seal deck hatches to make weathertight.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 26 November 2021
Resolved 23 November 2021
Resolution: Pictures of sealed hatches received.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 26 October 2021 Resolved
Provide ring life buoy light for one ring buoy with 3’ line & spring loaded clip. Prior to night ops.
Action required: 705 - Other - as specified
Resolved 29 November 2021
Resolution: Picture received.

Casualty record · 1

22 August 2010Routine · role: Involved in a Marine Casualty · activity 3835213
Each line is an incident investigation the Coast Guard recorded with this hull among the vessels involved, with the date and the classification the Coast Guard gave it. Involvement is not fault. The investigation narrative is not published. Source: IIR, through 2026.

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.