DIXIE BELLE

DIXIE BELLE is a 1983 passenger vessel (inspected). The Coast Guard has recorded 52 inspections since 1986, most recently in April 2026, along with 101 deficiencies and 1 casualty investigation in 2010.

Records from 1986 to 2026. Most recent: inspection, 16 April 2026.

Built
1983
Last inspected
16 April 2026
Documentation
Expired · documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

Flag
UNITED STATES
—
Maury page id
psix-54829

Inspections, by type

…with no type recorded4
Years with a record 33 calendar years (1986–2026)
The 52 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 1977.

Documentation record

Registered dimensions (L × B × D)51.5 ft × 20.0 ft × 4.5 ft
Registered tonnagegross 68 / net 68
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderR R & R A REYNOLDS INC · LONG BEACH, CA, UNITED STATES · built 1983
Hull materialSteel
PropulsionGasoline Outboard
Hull shapeShip
Hull configurationMonohull
Hailing portLAKE HAVASU CITY, AZ
Trade endorsementsCoastwise, unrestricted
DocumentationExpired · issued 30 June 2004
Service, as the file records itPassenger (Inspected)
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it68 - Simplified, Gross Ton
68 - Simplified, Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 September 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.

Radio station licence

No FCC ship-station licence is recorded against this Official Number in the file of 6 September 2026. That is a fact about the licence file, not about the radio.

Inspection history · 52

16 April 2026 Drydock Exam · Internal Structural Exam · Deficiency Check
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 8350029
7 January 2026 COI Inspection
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 8283979
6 January 2025 Annual Inspection
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 8050984
16 January 2024 Annual Inspection
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 7860004
22 May 2023 In-Service Inspection
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 7701007
7 September 2022 Annual Inspection · Administrative Inspection
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 7542602
26 October 2021 DAPI Audit · Initial Certification · Deficiency Check · COI Inspection
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 7335736
1 September 2021 COI Inspection
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 7285040
15 June 2021 In-Service Inspection · Simplified Stability Test
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 7256437
8 July 2019 Construction Oversight
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 6766791
27 March 2014 Construction Oversight · Administrative Inspection
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 4973749
27 September 2011 Administrative Inspection
Administrative · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 4155828
29 November 2010 Internal Structural Exam · Hull Examination
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 3899084
3 February 2010 Annual Inspection · DAPI Audit
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 3677749
20 January 2009 Annual Inspection
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 3389056
22 January 2008 COI Inspection
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 3126626
13 March 2006 Annual Inspection
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 2597217
12 January 2006 Hull Examination
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 2560718
7 February 2005 Annual Inspection
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 2283956
13 February 2004 Deficiency Check
Physical examination · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 2006113
20 January 2004 Annual Inspection
Physical examination · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 1994364
23 January 2003 COI Inspection
Physical examination · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 1734542
22 January 2002 Deficiency Check · Re-Inspection
Physical examination · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 1480529
23 August 2001 Deficiency Check
Physical examination · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 1071470
20 June 2001 Type not recorded
No type recorded · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 1067987
22 March 2001 Re-Inspection
Physical examination · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 1448263
23 January 2001 Hull Examination
Physical examination · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 1403291
9 February 2000 COI Inspection
Physical examination · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 1393342
20 March 1999 Deficiency Check
Physical examination · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 1113474
26 January 1999 Re-Inspection
Physical examination · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 1455666
4 February 1998 Re-Inspection
Physical examination · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 1418299
25 March 1997 Deficiency Check · COI Inspection
Physical examination · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 1409660
10 June 1996 Deficiency Check
Physical examination · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 1186662
26 March 1996 Re-Inspection
Physical examination · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 1417924
7 December 1995 Hull Examination
Physical examination · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 1462481
12 January 1995 Re-Inspection
Physical examination · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 1396240
5 July 1994 Deficiency Check
Physical examination · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 1171880
28 June 1994 Type not recorded
No type recorded · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 651746
23 May 1994 Deficiency Check
Physical examination · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 1169654
31 March 1994 COI Inspection
Physical examination · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 859901
30 March 1994 Type not recorded
No type recorded · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 664133
26 March 1994 Type not recorded
No type recorded · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 220138
29 March 1993 Re-Inspection
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 842121
30 March 1992 Re-Inspection
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 948214
10 April 1991 Administrative
Administrative · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1246170
3 April 1991 Hull Examination · COI Inspection
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1218008
3 April 1990 Re-Inspection
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1226837
4 April 1989 Re-Inspection
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 900505
30 March 1988 COI Inspection
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1301289
14 April 1987 Re-Inspection
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1311973
1 October 1986 Credit Drydock
Administrative · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1313111
29 January 1986 COI Inspection
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1292385

Deficiency record · 101

11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 7 January 2026 Resolved
A vessel must have one or more ring life buoys. Marine Inspector found the ring life buoy's line no longer serviceable. 46 CFR 180.70 (a)
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 21 January 2026
Resolved 26 February 2026
Resolution: Vessel added new life ring
11 - Life Saving Appliances › N/A - No Subsystem › Distress flares
Issued 7 January 2026 Resolved
Distress signals: Lakes, bays, and sounds, and rivers routes. A vessel on a lakes, bays, and sounds, or rivers route must carry: Three hand red flare distress signals approved in accordance with § 160.021 in subchapter Q of this chapter and three hand orange smoke distress signals approved in accordance with § 160.037 in subchapter Q of this chapter Marine Inspector found two expired hand flares. 46 CFR 180.68 (b)(1)(2)
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 21 January 2026
Resolved 26 February 2026
Resolution: Vessel has correct amount of flares
09 - Working and Living Conditions › 092 - Working Conditions › Warning notices
Issued 7 January 2026 Resolved
On a vessel on which the number of passengers permitted on upper decks is limited by stability criteria, as indicated by the vessel's stability letter, the maximum number of passengers allowed on an upper deck must be indicated by a durable marking of at least 25 millimeters (1 inch) numbers and letters at the entrance to that deck. 46 CFR 185.602 (g)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 21 January 2026
Resolved 26 February 2026
Resolution: Vessel operator installed sign
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 7 January 2026 Resolved
Each child size life jacket must be stowed in a location that is appropriately marked and separated from adult life jackets so the child size life jackets are not mistaken for adult life jackets. Marine Inspector found child life jackets not separate from adult life jackets. 46 CFR 180.78 (a)(5)
Condition: Design Flaw
Action required: 16 - Rectify deficiencies w/in 14 days
Due 21 January 2026
Resolved 26 February 2026
Resolution: Operator seperated lifejackets
07 - Fire Safety › N/A - No Subsystem › Fire detection and alarm system
Issued 7 September 2022 Resolved
46 CFR 181.420(a)(2) - The fixed gas extinguishing system must be operable from outside the space. The safety pin was installed in the system, rendering the remote operation cable disabled. Fixed on the spot.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 7 September 2022
Resolution: Fixed on the spot
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 7 September 2022 Resolved
The water heater is not fitted with a nameplate, and operating specifications could not be found. Demonstrate compliance with 46 CFR 182.320(a) by submitting specifications showing that the water heater’s capacity and heat input are below 120 gallons and 200,000 BTU/hr and that it is listed under UL 174 or UL 1453.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 7 October 2022
Resolved 14 September 2022
Resolution: Owner provided manufacturer spec sheet showing capacity and heat input are below 120 gallons and 200,000 BTU/hr and that it is UL approved. [name withheld]
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 7 September 2022 Resolved
46 CFR 183.220 - Remove all power strips onboard that are not suitable for service in a marine environment to the satisfaction of the attending marine inspector.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 7 October 2022
Resolved 6 January 2025
Resolution: Power strips removed.
04 - Emergency Systems › N/A - No Subsystem › Emergency source of power - Emergency generator
Issued 7 September 2022 Resolved
46 CFR 183.310(a)(1)(i) - Demonstrate that the fire pump and bilge pump are operable from a secondary source of power.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 7 October 2022
Resolved 6 January 2025
Resolution: Fire pump and bilge pump operational.
04 - Emergency Systems › N/A - No Subsystem › Emergency fire pump and its pipes
Issued 7 September 2022 Resolved
46 CFR 181.300(e) - Troubleshoot and repair intermittent failures on bridge remote fire pump start switch
Action required: 50 - Rectify deficiencies w/in 30 days
Due 7 October 2022
Resolved 14 September 2022
Resolution: Relay was tightened, testing onboard from remote switch in the pilothouse was satisfactory. [name withheld]
10 - Safety of Navigation › N/A - No Subsystem › Lights, shapes, sound-signals
Issued 7 September 2022 Resolved
33 CFR 86.01 - Troubleshoot and repair intermittent failures on compressor powering the ship’s horn
Action required: 50 - Rectify deficiencies w/in 30 days
Due 7 October 2022
Resolved 6 January 2025
Resolution: Ships horn operational.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 7 September 2022 Resolved
46 CFR 185.604(f) - All containers which are designated for storage of PFDs must be labeled with the number and identification of the PFDs stowed inside. Containers for child-sized PFDs must be labeled accordingly and segregated.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 7 October 2022
Resolved 6 January 2025
Resolution: PFD' labeled and stored properly.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Machinery space openings
Issued 7 September 2022 Resolved
46 CFR 176.800(a) - Access to the aft machinery and water tank spaces is currently made with a strip of tape on the hatch cover. Modify the hatch cover to facilitate easy access.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 7 October 2022
Resolved 6 January 2025
Resolution: Hatch modified.
11 - Life Saving Appliances › N/A - No Subsystem › Operational readiness of lifesaving appliances
Issued 7 September 2022 Resolved
46 CFR 180.70(d) - Renew the battery in the ring buoy float light. Perform an operational test of the light to the satisfaction of the attending marine inspector.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 7 October 2022
Resolved 14 September 2022
Resolution: Battery installed and light working as designed - [name withheld]
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 7 September 2022 Resolved
46 CFR 183.354(b) - Modify the battery installation such that it is protected from falling objects
Action required: 50 - Rectify deficiencies w/in 30 days
Due 7 October 2022
Resolved 6 January 2025
Resolution: Batteries protected from falling objects.
07 - Fire Safety › N/A - No Subsystem › Fixed fire extinguishing installation
Issued 26 October 2021 Resolved
Pre-engineered fixed gas fire extinguishing system installed must be capable of manual actuation from outside the space in addition to automatic heat activation. Properly install manual pull cable and mark with directions to activate system.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 23 November 2021
Resolution: Received tech report from Arizona West Fire & Safety attesting to installation and testing of manual pull cable.
07 - Fire Safety › N/A - No Subsystem › Fixed fire extinguishing installation
Issued 26 October 2021 Resolved
Pre-engineered fixed gas fire extinguishing system installed must automatically shut down all power ventilation fans and engines that draw intake air from the space protected and be provided with a means to reset fans/engines. Properly install shutdown and reset devices for fans and generator. Provide 3rd party servicing report of proper operation.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 23 November 2021
Resolution: Received tech report from Arizona West Fire & Safety attesting to testing of pressure switch for generator and blower shutdown.
04 - Emergency Systems › N/A - No Subsystem › Water level indicator
Issued 26 October 2021 Resolved
An unmanned machinery space bilge subject to flooding from sea water piping within the space must be provided with a visual and audible alarm at the operating station to indicate high water level. Properly install an intrinsically safe bilge high water alarm in the generator space.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 23 November 2021
Resolution: Received picture and video of working bilge alarm.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 26 October 2021 Resolved
Provide 56 adult & 09 child Type I lifejackets. Pax count reduced to 79 adults & 05 children. Update 11/4 - all children lifejackets on board. Update 11/23 - 40 additional adult lifejackets on board. Update 12/13 - 16 additional adult lifejackets on board.
Action required: 705 - Other - as specified
Resolved 13 December 2021
Resolution: Spoke with POC. All lifejackets marked and on board. Picture added to vessel file.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 26 October 2021 Resolved
Add master to random drug testing program or shared agreement from other company's program.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 26 November 2021
Resolved 23 November 2021
Resolution: Received proof of new USCG Consortium, master's pre-employment testing and full active random testing pool
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 26 October 2021 Resolved
Mark both stairwells to upper deck "Max Passengers 54."
Action required: 50 - Rectify deficiencies w/in 30 days
Due 26 November 2021
Resolved 4 November 2021
Resolution: Recieved pictures of max passengers 54 at each stairwell.
10 - Safety of Navigation › N/A - No Subsystem › Magnetic compass
Issued 26 October 2021 Resolved
Install illuminated magnetic compass. Illumination required prior to nighttime/reduced visibility ops.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 26 November 2021
Resolved 4 November 2021
Resolution: Received picture of illuminated magnetic compass.
10 - Safety of Navigation › N/A - No Subsystem › Charts
Issued 26 October 2021 Resolved
Provide chart of Lake Havasu.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 26 November 2021
Resolved 23 November 2021
Resolution: Lake Havasu map provided.
11 - Life Saving Appliances › N/A - No Subsystem › Distress flares
Issued 26 October 2021 Resolved
Provide watertight case for/marked “Distress Signals.”
Action required: 50 - Rectify deficiencies w/in 30 days
Due 26 November 2021
Resolved 4 November 2021
Resolution: Received picture.
11 - Life Saving Appliances › N/A - No Subsystem › Other (life saving)
Issued 26 October 2021 Resolved
Renew blocks for rescue platform.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 26 November 2021
Resolved 4 November 2021
Resolution: Received picture of new blocks installed.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 26 October 2021 Resolved
Provide portable hand bilge pump with sufficient hose length. (5 Gallons per minute capacity)
Action required: 50 - Rectify deficiencies w/in 30 days
Due 26 November 2021
Resolved 23 November 2021
Resolution: Picture of hand pump and 25' hose provided.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 26 October 2021 Resolved
Make lip for battery box to prevent battery acid from leaking onto deck.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 26 November 2021
Resolved 29 November 2021
Resolution: Picture received.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 26 October 2021 Resolved
Add additional length (50’) of anchor line.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 26 November 2021
Resolved 4 November 2021
Resolution: Received picture.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Covers (hatchway-, portable-, tarpaulins, etc.)
Issued 26 October 2021 Resolved
Seal deck hatches to make weathertight.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 26 November 2021
Resolved 23 November 2021
Resolution: Pictures of sealed hatches received.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 26 October 2021 Resolved
Provide ring life buoy light for one ring buoy with 3’ line & spring loaded clip. Prior to night ops.
Action required: 705 - Other - as specified
Resolved 29 November 2021
Resolution: Picture received.
Lifesaving › Lifejacket/PFD (Type I) › Condition
Issued 22 January 2008 Resolved
Replace (26) adult lifejackets so a total of 125 serviceable adult lifejackets are onboard. Ensure lifejackets that are replaced are USCG approved Type-1. Vessel is restricted to carry not more than 99 total persons until corrected.
Due 7 February 2008
Resolved 4 February 2008
Electrical › Electrical Distribution System (service)
Issued 20 January 2004 Resolved
Properly wire sewage discharge pump to switch and distribution panel. LEGACY COMPONENT DESC: Wiring
Due 20 February 2004
Resolved 11 February 2004
Resolution: Sewage pump rewired properly
Lifesaving › Lifejacket/PFD (General)
Issued 20 January 2004 Resolved
Provide proper liefe jacket donning placard. LEGACY COMPONENT DESC: Donning Placard
Due 20 February 2004
Resolved 11 February 2004
Resolution: New placard installed.
Lifesaving › Lifebuoys
Issued 20 January 2004 Resolved
Renew float light battery. LEGACY COMPONENT DESC: Self-igniting Lights
Due 20 February 2004
Resolved 11 February 2004
Resolution: New battery installed
Electrical › Electrical Distribution System (service)
Issued 10 January 2002 Resolved
Use butt connectors on wire connections, (bilge alarm, vapor detector, radio, etc.) LEGACY COMPONENT DESC: Wiring
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 1 February 2002
Resolved 30 January 2002
Engineering › Generator (propulsion/auxiliary-electric)
Issued 10 January 2002 Resolved
Provide proper exhaust blower ignition interlock switch for generator space. LEGACY COMPONENT DESC: Contactor Circuitry
Condition: Placed in Improper Service
Action required: 705 - Other - as specified
Due 1 February 2002
Resolved 30 January 2002
Documentation
Issued 22 March 2001 Resolved
POST STABILITY LETTER IN PILOTHOUSE IAW 46CFR 176.306
Condition: Unknown
Due 14 May 2001
Resolved 14 May 2001
Electrical
Issued 22 March 2001 Resolved
COVER BLANK SPACE IN GENERATOR SPACE POWER PANEL.
Condition: Unknown
Due 14 May 2001
Resolved 14 May 2001
Navigation
Issued 22 March 2001 Resolved
OBTAIN ANCHOR LIGHT IAW COLREGS. MUST BE COMPLETED BEFORE CARRYING PASSENGERS.
Condition: Unknown
Due 14 May 2001
Resolved 14 May 2001
Lifesaving
Issued 22 March 2001 Resolved
RENEW EYE DRESSING, WIRE SPLINT, TRIANGULAR BANDAGE, IODINE, AND BURN DRESSING.
Condition: Unknown
Due 22 March 2001
Resolved 22 March 2001
Electrical
Issued 23 January 2001 Resolved
Install metalic piping for generator sea water cooling suction. Install cutout valve for toilet water suction IAW 46CFR181.420 & 710. Complete prior to carrying passengers.
Condition: Unknown
Due 23 January 2001
Resolved 23 January 2001
Construction/Loadline
Issued 23 January 2001 Resolved
Renew identified hull plating as discussed during dry dock examination. Repairs to made to the satisfaction of USCG marine inspector. See MINS forexact plate requirements.
Condition: Unknown
Due 23 January 2001
Resolved 23 January 2001
Documentation
Issued 23 January 2001 Resolved
Provide 1999 drug test reports and employee list.
Condition: Unknown
Due 23 January 2001
Resolved 23 January 2001
Electrical
Issued 23 January 2001 Resolved
Provide electrical specifications and installation drawings for new A/C unit.
Condition: Unknown
Due 23 January 2001
Resolved 23 January 2001
Construction/Loadline
Issued 23 January 2001 Resolved
Provide visual bilge alarms at operating station.
Condition: Unknown
Due 23 January 2001
Resolved 23 January 2001
Engineering
Issued 23 January 2001 Resolved
Provide proposal for manufacturing of new gasoline tanks and install new tanks IAW 46CFR 182.440, 182.445, 182.450, 182.455. Complete prior to carrying passengers.
Condition: Unknown
Due 23 January 2001
Resolved 23 January 2001
Engineering
Issued 23 January 2001 Resolved
Install remote fuel shut offs for fuel tanks. Complete before carrying passengers.
Condition: Unknown
Due 23 January 2001
Resolved 23 January 2001
Engineering
Issued 9 February 2000 Resolved
Install proper supply fitting on fuel tank.
Condition: Unknown
Due 9 February 2000
Resolved 9 February 2000
Lifesaving
Issued 9 February 2000 Resolved
Mount fume detection sensors.
Condition: Unknown
Due 9 February 2000
Resolved 9 February 2000
Construction/Loadline
Issued 9 February 2000 Resolved
Install valve at start of plastic piping from bilge system to sewaqge tank.
Condition: Unknown
Due 9 February 2000
Resolved 9 February 2000
Electrical
Issued 9 February 2000 Resolved
Remove all household type wiring from vessel. (Main power panel, generator room.)
Condition: Unknown
Due 9 February 2000
Resolved 9 February 2000
Electrical
Issued 9 February 2000 Resolved
Remove hose from over generator panel.
Condition: Unknown
Due 9 February 2000
Resolved 9 February 2000
Documentation
Issued 9 February 2000 Resolved
Provide drug testing program information.
Condition: Unknown
Due 9 February 2000
Resolved 9 February 2000
Electrical
Issued 9 February 2000 Resolved
Renew generator R/W cooling line and fitting.
Condition: Unknown
Due 9 February 2000
Resolved 9 February 2000
Lifesaving
Issued 26 January 1999 Resolved
Provide 26 additional adult life jackets.
Condition: Unknown
Due 26 January 1999
Resolved 26 January 1999
Lifesaving
Issued 26 January 1999 Resolved
Provide 7 additional child life jackets.
Condition: Unknown
Due 26 January 1999
Resolved 26 January 1999
Navigation
Issued 26 January 1999 Resolved
Provide emergency broadcast plaque near radio.
Condition: Unknown
Due 26 January 1999
Resolved 26 January 1999
Electrical
Issued 26 January 1999 Resolved
Seal generator compartmant.
Condition: Unknown
Due 26 January 1999
Resolved 26 January 1999
Lifesaving
Issued 4 February 1998 Resolved
Provide additional Ring Buoy for stern of vessel. Buoy does not have to have light or line attached.
Condition: Unknown
Due 13 February 1998
Resolved 13 February 1998
Accommodation/Occupational Safety
Issued 4 February 1998 Resolved
PROVIDE WASTE PLAN FOR VESSEL.
Condition: Unknown
Due 13 February 1998
Resolved 13 February 1998
Fire Fighting
Issued 4 February 1998 Resolved
Provide proper closures for vents on fixed firefighting spaces.
Condition: Unknown
Due 13 February 1998
Resolved 13 February 1998
Lifesaving
Issued 4 February 1998 Resolved
PROVIDE PASSENGER COUNT TO A SHORESIDE LOCATION.
Condition: Unknown
Due 13 February 1998
Resolved 13 February 1998
Lifesaving
Issued 4 February 1998 Resolved
Provide complete first aid kit and remove expired medicines.
Condition: Unknown
Due 13 February 1998
Resolved 13 February 1998
Lifesaving
Issued 25 March 1997 Resolved
RENEW LIFERING BUOY LINE
Condition: Unknown
Due 14 April 1997
Resolved 14 April 1997
Lifesaving
Issued 25 March 1997 Resolved
POST LIFEJACKET PLACARD
Condition: Unknown
Due 14 April 1997
Resolved 14 April 1997
Fire Fighting
Issued 25 March 1997 Resolved
HAVE ON BOARD 3 FIREBUCKETS
Condition: Unknown
Due 14 April 1997
Resolved 14 April 1997
Documentation
Issued 25 March 1997 Resolved
PROVIDE LOGS FOR CREW TRAINING, AND LIFESAVING INSPECTIONS
Condition: Unknown
Due 14 April 1997
Resolved 14 April 1997
Accommodation/Occupational Safety
Issued 25 March 1997 Resolved
RELOCATE MSD VENTS
Condition: Unknown
Due 14 April 1997
Resolved 14 April 1997
Electrical
Issued 25 March 1997 Resolved
REPAIR WIRING UNDER CONSOLE
Condition: Unknown
Due 14 April 1997
Resolved 14 April 1997
Lifesaving
Issued 25 March 1997 Resolved
LABEL EMERGENCY DISTRESS CONTAINER
Condition: Unknown
Due 14 April 1997
Resolved 14 April 1997
Deck/Cargo
Issued 25 March 1997 Resolved
INSTALL CABLE CLAMPS ON FWD BOOM CORRECTLY
Condition: Unknown
Due 25 March 1997
Resolved 25 March 1997
Construction/Loadline
Issued 25 March 1997 Resolved
RENEW FLEXIBLE HOSE ON BILGE SUCTION LINE IN WAY OF FOREPEAK VOID
Condition: Unknown
Due 14 April 1997
Resolved 14 April 1997
Construction/Loadline
Issued 25 March 1997 Resolved
INSTALL SCREWS IN MAIN DECK ACCESS PLATES AND MAKE W/T
Condition: Unknown
Due 14 April 1997
Resolved 14 April 1997
Engineering
Issued 25 March 1997 Resolved
INSTALL INTERLOK DEVICE ON START CIRCUIT OF GENERATOR ENGINE TO PREVENT STARTER ENGAGE WITHOUT VENT BLOWER OPERATION
Condition: Unknown
Due 14 April 1997
Resolved 14 April 1997
Navigation
Issued 26 March 1996 Resolved
Horn obstructs fwd white nav light. Remove horn or light to new location toclear obstruction.
Condition: Unknown
Due 26 March 1996
Resolved 26 March 1996
Navigation
Issued 26 March 1996 Resolved
Replace broken aft white navigation light lens.
Condition: Unknown
Due 26 March 1996
Resolved 26 March 1996
Construction/Loadline
Issued 7 December 1995 Resolved
PROPERLY RENEW REACH ROD, VALVE AND 6 INCHES OF BILGE PIPING LOCATED IN THENUMBER ONE STARBOARD VOID JUST AFT OF THE COLLISION BULKHEAD.
Condition: Unknown
Due 7 December 1995
Resolved 3 January 1996
Construction/Loadline
Issued 7 December 1995 Resolved
PROPERLY CLAD WELD ALL PITS IN HULL WITH GREATER THAN 25 PERCENT WASTEAGE OF HULL MATERIAL
Condition: Unknown
Due 7 December 1995
Resolved 3 January 1996
Construction/Loadline
Issued 12 January 1995 Resolved
Remove flex hose (outboard of sea valve) from bilge overboard discharge.
Condition: Unknown
Due 12 January 1995
Resolved 12 January 1995
Construction/Loadline
Issued 12 January 1995 Resolved
Renew marine sanitation device overboard discharge with metallic through- hull fitting and install a valve.
Condition: Unknown
Due 12 January 1995
Resolved 12 January 1995
Accommodation/Occupational Safety
Issued 31 March 1994 Resolved
MAKE PERMANENT REPAIRS TO THE BROKEN STEP TREADS FOR THE PORT AND STARBOARDSTAIRWAYS.
Condition: Unknown
Due 31 March 1994
Resolved 31 March 1994
Lifesaving
Issued 31 March 1994 Resolved
PROVIDE 6 ORANGE SMOKE DISTRESS SIGNALS (FLARES).
Condition: Unknown
Due 31 March 1994
Resolved 31 March 1994
Navigation
Issued 31 March 1994 Resolved
PROVIDE LOCKING NUTS FOR OUTBOARD MOTOR'S STEERING CONNECTING RODS.
Condition: Unknown
Due 30 April 1994
Resolved 16 May 1994
Electrical
Issued 31 March 1994 Resolved
PROVIDE A SPLASH SHIELD OVER THE PANEL BOX IN THE GENERATOR ROOM.
Condition: Unknown
Due 30 April 1994
Resolved 16 May 1994
Fire Fighting
Issued 31 March 1994 Resolved
PROPERLY MARK CABINET CONTAINING FIRE PUMP REMOTE OPERATION SWITCH.
Condition: Unknown
Due 30 April 1994
Resolved 16 May 1994
Electrical
Issued 31 March 1994 Resolved
REMOVE ROMEX TYPE WIRING FOR REMOTE FIRE PUMP SWITCH AND PROPERLY INSTALL MARINE GRADE WIRING.
Condition: Unknown
Due 30 April 1994
Resolved 16 May 1994
Lifesaving
Issued 31 March 1994 Resolved
MOVE RING BUOY WITH LIGHT TO VICINITY OF PILOTHOUSE.
Condition: Unknown
Due 30 April 1994
Resolved 16 May 1994
Fire Fighting
Issued 29 March 1993 Resolved
PROVIDE A REMOTE START/STOP SWITCH FOR THE FIRE PUMP. SWITCH MUST BE_x001C_ LOCATED OUTSIDE THE MACHINERY SPACE. _x001C_ _x001C_ _x001C_
Condition: Unknown
Due 29 March 1993
Resolved 29 March 1993
Unknown
Issued 29 March 1993 Resolved
[withheld — contains personal information; the deficiency system, dates, and resolution status are shown above]
Condition: Unknown
Due 29 March 1993
Resolved 29 March 1993
Electrical
Issued 3 April 1990 Resolved
LINE BATTERY BOX WITH A CORROSION RESISTANT LINING.
Condition: Unknown
Due 3 April 1990
Resolved 3 April 1990
Lifesaving
Issued 3 April 1990 Resolved
PROVIDE 6 HAND HELD RED FLARES AND 6 HAND HELD ORANGE SMOKE DISTRESS SIGNALS.
Condition: Unknown
Due 3 April 1990
Resolved 3 April 1990
Electrical
Issued 3 April 1990 Resolved
REMOVE SOLID CONDUCTOR CABLE ON MSD PUMP AND REWIRE WITH APPROVED STRANDED CABLE.
Condition: Unknown
Due 3 April 1990
Resolved 3 April 1990
Lifesaving
Issued 3 April 1990 Resolved
PROVIDE OPERABLE WATERLIGHT TO RING BUOY.
Condition: Unknown
Due 3 April 1990
Resolved 3 April 1990
Electrical
Issued 3 April 1990 Resolved
PERMANENTLY HARDWIRE FIRE/BILGE PUMP IN WAY OF PRESENT PLUG IN.
Condition: Unknown
Due 3 April 1990
Resolved 3 April 1990
Documentation
Issued 3 April 1990 Resolved
PROVIDE PROOF OF CURRENT FCC STATION LICENSE.
Condition: Unknown
Due 3 April 1990
Resolved 3 April 1990
Fire Fighting
Issued 4 April 1989 Resolved
PROVIDE INSTRUCTIONS FOR OPERATION OF FUEL TANK SPACE AND MACHINERY SPACE FIXED CO2 SYSTEMS IAW 46 CFR 181.20-15.
Condition: Unknown
Due 4 April 1989
Resolved 4 April 1989
Engineering
Issued 4 April 1989 Resolved
RENEW FUEL HOSES FROM TANKS TO FUEL FILTERS WHERE DETERIORATED.
Condition: Unknown
Due 4 April 1989
Resolved 4 April 1989
Electrical
Issued 4 April 1989 Resolved
PROVIDE A SUITABLE BATTERY BOX INSTALLATION FOR 12V BATTERY BANK WITH AN ACID-RESISTANT LINING IAW 46 CFR 183.05-20.
Condition: Unknown
Due 4 April 1989
Resolved 4 April 1989
Navigation
Issued 4 April 1989 Resolved
PROVE PROPER OPERATION OF VESSEL'S WHISTLE PRIOR TO CARRYING PASSENGERS.
Condition: Unknown
Due 4 April 1989
Resolved 4 April 1989
Fire Fighting
Issued 4 April 1989 Resolved
PROVIDE ON BOARD 2 BII EXTINGUISHERS FOR EACH ACCOMMODATION SPACE IAW 46 CFR 181.30-1 IN PLACE OF EXISTING BI EXTINGUISHERS.
Condition: Unknown
Due 4 April 1989
Resolved 4 April 1989
Fire Fighting
Issued 4 April 1989 Resolved
PROVIDE PROOF OF ANNUAL WEIGHING/SERVICING OF FUEL TANK SPACE AND MACHINERYSPACE FIXED CO2 SYSTEM; THIS IS TO BE COMPLETED PRIOR TO CARRYING PASSENGERS.
Condition: Unknown
Due 4 April 1989
Resolved 4 April 1989
Electrical
Issued 4 April 1989 Resolved
PERMANENTLY SECURE GENERATOR SPACE VENT FAN MOTOR WHERE ADRIFT.
Condition: Unknown
Due 4 April 1989
Resolved 4 April 1989

Casualty record · 1

22 August 2010Routine · role: Involved in a Marine Casualty · activity 3835213
Each line is an incident investigation the Coast Guard recorded with this hull among the vessels involved, with the date and the classification the Coast Guard gave it, and the bridge, lock or dam the investigation names where it names one. Involvement is not fault. The investigation narrative is not published. Source: IIR, through 2026.

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.