Records from 1983 to 1985. Most recent: inspection, 22 February 1985.
A report is not offered for this hull: Its record holds only 2 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. Reports.
Lifesaving
Issued 22 February 1985
Resolved
REPAIR ALL ESCAPE LADDERS SO THAT THEY REACH THE WATER LEVEL AT THE VESSELSLIGHTEST DRAFT: REF, 46 CFR 108.525.
Condition: Unknown
Due 22 June 1985
Resolved 18 May 2002
Resolution: MISLE Maintenance - Resolved all open deficiencies issued prior to 6/1/1997 where activity was closed and deficiency due date was past
Electrical
Issued 22 February 1985
Resolved
REMOVE PLASTIC TIE WRAPS USED TO SUPPORT WIRING IN NON SUPPORTED CABLE RUNSAND REPLACE WITH STEEL STRAPPING. 46 CFR 110.10(1EEE STD 45).
Condition: Unknown
Due 22 June 1985
Resolved 18 May 2002
Resolution: MISLE Maintenance - Resolved all open deficiencies issued prior to 6/1/1997 where activity was closed and deficiency due date was past
Documentation
Issued 22 February 1985
Resolved
PROVIDE THE RIG WITH A VALID IOPP CERTIFICATE. SEND A COPY OF THE CERTIFI-CATE TO THE MARINE INSPECTION OFFICE NEW ORLEANS, UPON ISSUANCE. 46 CFR 151.19
Condition: Unknown
Due 22 June 1985
Resolved 18 May 2002
Resolution: MISLE Maintenance - Resolved all open deficiencies issued prior to 6/1/1997 where activity was closed and deficiency due date was past
Unknown
Issued 22 February 1985
Resolved
MAKE AVAILABLE FOR INTERNAL EXAMINATION BY A COAST GUARD INSPECTOR, THE NUMBER 1 AND 2 BULK TANKS. 46 CFR 54.
Condition: Unknown
Due 22 June 1985
Resolved 18 May 2002
Resolution: MISLE Maintenance - Resolved all open deficiencies issued prior to 6/1/1997 where activity was closed and deficiency due date was past
Unknown
Issued 22 February 1985
Resolved
THE FOLLOWING DEFICIENCIES PERTAIN TO THE FOREIGN MODU LOUISIANA VIN: LN160071.
Condition: Unknown
Due 22 June 1985
Resolved 18 May 2002
Resolution: MISLE Maintenance - Resolved all open deficiencies issued prior to 6/1/1997 where activity was closed and deficiency due date was past
Construction/Loadline
Issued 22 February 1985
Resolved
REPAIR THE WASTED DOOR FRAME TO THE PORT GENERATOR ROOM WEATHER TIGHT DOOR.46 CFR 108.113.
Condition: Unknown
Due 22 June 1985
Resolved 18 May 2002
Resolution: MISLE Maintenance - Resolved all open deficiencies issued prior to 6/1/1997 where activity was closed and deficiency due date was past
Navigation
Issued 24 February 1984
Resolved
PROVIDE THREE (3) BLACK BALL DAY SHAPES FOR THE VESSEL (SIGNAL FOR "AGROUND").
Condition: Unknown
Due 24 March 1984
Resolved 18 May 2002
Resolution: MISLE Maintenance - Resolved all open deficiencies issued prior to 6/1/1997 where activity was closed and deficiency due date was past
Fire Fighting
Issued 24 February 1984
Resolved
PROVIDE SPANNER WRENCHES FOR FIRE STATIONS ONE AND TWO.
Condition: Unknown
Due 24 March 1984
Resolved 18 May 2002
Resolution: MISLE Maintenance - Resolved all open deficiencies issued prior to 6/1/1997 where activity was closed and deficiency due date was past
Electrical
Issued 24 February 1984
Resolved
PROVIDE ILLUMIATION AT THE WATER FOR LIFERAFTS NUMBER FOUR (4) AND SEVEN (7). THESE LIGHTS ARE TO BE CONNECTED TO AN EMERGENCY SOURCE OF POWER.
Condition: Unknown
Due 24 March 1984
Resolved 18 May 2002
Resolution: MISLE Maintenance - Resolved all open deficiencies issued prior to 6/1/1997 where activity was closed and deficiency due date was past
Unknown
Issued 24 February 1984
Resolved
(REQ. 6 CONTINUE) ON THOSE AREAS OVER DOORWAYS AND ARCHWAYS WHERE PERSONNELTRANSIT.
Condition: Unknown
Due 24 March 1984
Resolved 18 May 2002
Resolution: MISLE Maintenance - Resolved all open deficiencies issued prior to 6/1/1997 where activity was closed and deficiency due date was past
Unknown
Issued 24 February 1984
Resolved
PROVIDE DOCUMENTATION ON THE FORKLIFT TO SHOW THAT IT IS SUITABLE FOR USE IN A CLASSIFIED LOCATION.
Condition: Unknown
Due 24 March 1984
Resolved 18 May 2002
Resolution: MISLE Maintenance - Resolved all open deficiencies issued prior to 6/1/1997 where activity was closed and deficiency due date was past
Electrical
Issued 24 February 1984
Resolved
REMOVE THE DEADEND WIRE LOCATED AT THE PORT SIDE MAIN DECK LEVEL NEAR THE SANITARY TANK.
Condition: Unknown
Due 24 March 1984
Resolved 18 May 2002
Resolution: MISLE Maintenance - Resolved all open deficiencies issued prior to 6/1/1997 where activity was closed and deficiency due date was past
Accommodation/Occupational Safety
Issued 24 February 1984
Resolved
TEST THE RELIEF VALVE AND INTERNALLY EXAMINE THE DRILL FLOOR AIR RECEIVER.
Condition: Unknown
Due 24 March 1984
Resolved 18 May 2002
Resolution: MISLE Maintenance - Resolved all open deficiencies issued prior to 6/1/1997 where activity was closed and deficiency due date was past
Construction/Loadline
Issued 24 February 1984
Resolved
REPAIR THE NUMBER ONE (1) BALLAST PUMP GASKET.
Condition: Unknown
Due 24 March 1984
Resolved 18 May 2002
Resolution: MISLE Maintenance - Resolved all open deficiencies issued prior to 6/1/1997 where activity was closed and deficiency due date was past
Electrical
Issued 24 February 1984
Resolved
REPAIRTHE REVERSE POWER PROTECTION DEVICES ON THE MAIN GENERATORS.
Condition: Unknown
Due 24 March 1984
Resolved 18 May 2002
Resolution: MISLE Maintenance - Resolved all open deficiencies issued prior to 6/1/1997 where activity was closed and deficiency due date was past
Unknown
Issued 24 February 1984
Resolved
INSTALL FLAME SCREENS ON THE THREE STARBOARD FUEL OIL AND LUBE OIL VENTS LOCATED IN THE ENGINE ROOM.
Condition: Unknown
Due 24 March 1984
Resolved 18 May 2002
Resolution: MISLE Maintenance - Resolved all open deficiencies issued prior to 6/1/1997 where activity was closed and deficiency due date was past
Unknown
Issued 24 February 1984
Resolved
REPAIR GUARD FOR AIR TUGGER AT BOP STACK.
Condition: Unknown
Due 23 March 1984
Resolved 18 May 2002
Resolution: MISLE Maintenance - Resolved all open deficiencies issued prior to 6/1/1997 where activity was closed and deficiency due date was past
Unknown
Issued 24 February 1984
Resolved
THE FOLLOWING DEFICIENCIES PERTAIN TO THE FOREIGN MODU LOUISIANA, LN160071.
Condition: Unknown
Due 23 March 1984
Resolved 18 May 2002
Resolution: MISLE Maintenance - Resolved all open deficiencies issued prior to 6/1/1997 where activity was closed and deficiency due date was past
Electrical
Issued 24 February 1984
Resolved
REMOVE THE PLASTIC TIE WRAPS USED TO SUPPORT WIRING IN NON-SUPPORTED CABLE RUNS, AND REPLACE WITH STEEL STRAPPING. EMPHASIS SHOUL BE INITIALLY PLACED
Condition: Unknown
Due 24 March 1984
Resolved 18 May 2002
Resolution: MISLE Maintenance - Resolved all open deficiencies issued prior to 6/1/1997 where activity was closed and deficiency due date was past
Electrical
Issued 24 February 1984
Resolved
LABEL ALL THE EMERGENCY LIGHTING ON THE VESSEL WITH A RED "E".
Condition: Unknown
Due 24 March 1984
Resolved 18 May 2002
Resolution: MISLE Maintenance - Resolved all open deficiencies issued prior to 6/1/1997 where activity was closed and deficiency due date was past
Unknown
Issued 2 September 1983
Resolved
THE FOLLOWING DEFICIENCY PERTAINS TO THE MODU LOUISIANA, LN160071.
Condition: Unknown
Due 2 September 1983
Resolved 2 September 1983
Unknown
Issued 20 June 1983
Resolved
THE FOLLOWING DEFICIENCY PERTAINS TO THE VESSEL LOUISIANA, LN160071.
Condition: Unknown
Due 20 June 1983
Resolved 20 June 1983
Electrical
Issued 20 June 1983
Resolved
MAKE ELECTRICAL CONNECTIONS ON DRAWWORKS MOTORS SUITABLE FOR THE HAZARDOUS LOCATION.
Condition: Unknown
Due 20 June 1983
Resolved 20 June 1983
Unknown
Issued 17 February 1983
Resolved
HAVE CRANES CERTIFIED BY A RECOGNIZED INSPECTION AGENCY (ABS OR ICGB) PRIOR TO 25MAR83.
Condition: Unknown
Due 10 April 1983
Resolved 17 February 1983
Unknown
Issued 17 February 1983
Resolved
PROVIDE COAST GUARD APPROVED OPERATIONS MANUAL PRIOR TO 24OCT83
Condition: Unknown
Due 24 October 1984
Resolved 17 February 1983
Unknown
Issued 17 February 1983
Resolved
(REQ. 7 CONTINUED) AVAILABLE FOR INTERNAL EXAM OR HYDROSTATIC TEST AT 1 1/4THE MAWP. IN ADDITON ENSURE THE RELIEF VALVE FOR THIS AIR RECEIVER IS SET
Condition: Unknown
Due 1 June 1983
Resolved 17 February 1983
Unknown
Issued 17 February 1983
Resolved
AT OR BELOW THE MAWP AND HAVE THIS RELIEF VALVE AVAILABLE FOR INSPECTION.
Condition: Unknown
Due 1 June 1983
Resolved 17 February 1983
Unknown
Issued 17 February 1983
Resolved
DRYDOCK RIG OR MAKE AVAILABLE FOR SPECIAL EXAMINATION IN LIEU OF DRYDOCKINGPRIOR TO 25OCT83.
Condition: Unknown
Due 25 October 1983
Resolved 17 February 1983
Lifesaving
Issued 17 February 1983
Resolved
PROVIDE ONE ADDITIONAL OXYGEN METER PRIOR TO 25MAR83.
Condition: Unknown
Due 10 April 1983
Resolved 17 February 1983
Unknown
Issued 17 February 1983
Resolved
PROVIDE LOADLINE OR FREEBOARD ASSIGNMENT PRIOR TO 25OCT83.
Condition: Unknown
Due 25 October 1983
Resolved 17 February 1983
Documentation
Issued 17 February 1983
Resolved
PROVIDE COAST GUARD ACCEPTED FIRE CONTROL/LIFESAVING PLAN & HAZARDOUS LOCATIONS PLAN PRIOR TO 25OCT83.
Condition: Unknown
Due 25 October 1983
Resolved 17 February 1983
Unknown
Issued 17 February 1983
Resolved
PROVIDE DOCUMENTATION OF THE MAXIMUM ALLOWABLE WORKING PRESSURE FOR THE DRILL FLOOR AIR RECEIVER. UPON THIS DETERMINATION MAKE THE AIR RECEIVER
Condition: Unknown
Due 1 June 1983
Resolved 17 February 1983