A report is not offered for this hull: Its record holds only 2 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. Reports.
Fire Fighting
Issued 16 July 1993
Resolved
INSTALL OPERATING INSTRUCTIONS AT ALL FIXED FIREFIGHTING ACTUATION STATIONS.
Condition: Unknown
Due 16 July 1993
Resolved 16 July 1993
Lifesaving
Issued 16 July 1993
Resolved
INSTALL CHEMICAL LIGHT ON TOP LIFEPRESERVER AT PORT DAVIT LAUNCHED RAFT STATION.
Condition: Unknown
Due 16 July 1993
Resolved 16 July 1993
Lifesaving
Issued 16 July 1993
Resolved
PLACE YELLOW RETRIEVAL LINE ON CABLE AND DAVIT FOR DAVIT LAUNCHED RAFT STATIONS AS SHOWN ON INSTRUCTION PLACARDS.
Condition: Unknown
Due 16 July 1993
Resolved 16 July 1993
Lifesaving
Issued 16 July 1993
Resolved
PROPERLY PAINT BRAKE LEVER HANDLE PER INSTRUCTION PLACARDS ON BOTH DAVIT LAUNCHED RAFT STATIONS.
Condition: Unknown
Due 16 July 1993
Resolved 16 July 1993
Lifesaving
Issued 16 July 1993
Resolved
TEST HYDROSTATIC RELEASES FOR LIFERAFTS #1, 3, AND 4 WHICH ARE OVERDUE FOR TESTING.
Condition: Unknown
Due 16 July 1993
Resolved 16 July 1993
Documentation
Issued 16 July 1993
Resolved
UPDATE LIFESAVING PLAN TO SHOW ADDITION OF 3RD LIFEBOAT.
Condition: Unknown
Due 16 July 1993
Resolved 16 July 1993
Electrical
Issued 16 July 1993
Resolved
INSTALL GLOBES AND GUARDS AS NEEDED IN REEFER/FREEZERS.
Condition: Unknown
Due 16 July 1993
Resolved 16 July 1993
Electrical
Issued 16 July 1993
Resolved
MAKE EMERGENCY BATTERY OPERATED LIGHT OUTSIDE COMPANY OFFICE OPERATE AT FULL INTENSITY (WEAK).
Condition: Unknown
Due 16 July 1993
Resolved 16 July 1993
Electrical
Issued 16 July 1993
Resolved
REPLACE CRACKED EXPLOSION PROOF PLUG AT CEMENTING UNIT.
Condition: Unknown
Due 16 July 1993
Resolved 16 July 1993
Lifesaving
Issued 16 July 1993
Resolved
REPLACE FLOAT STROBE LIGHTS AT RING BOUY AT BASE OF PORT STAIRWAY ON QUARTERS (LENSE BROKEN OFF) AND BY PORT LIFEBOAT (PINS MISSING).
Condition: Unknown
Due 16 July 1993
Resolved 16 July 1993
Lifesaving
Issued 16 July 1993
Resolved
HYDROSTATICALLY TEST SCBA BOTTLE AT HELO DECK.
Condition: Unknown
Due 16 July 1993
Resolved 16 July 1993
Engineering
Issued 16 July 1993
Resolved
INSTALL DRIP PANS FOR FUEL NOZZLES AT ALL REFUELING STATIONS (ie STBD CRANE, OLD WIRELINE AREA TOP OF QUARTERS).
Condition: Unknown
Due 16 July 1993
Resolved 16 July 1993
Construction/Loadline
Issued 16 July 1993
Resolved
REPLACE BROKEN GLASS IN WINDOW IN RADIO ROOM.
Condition: Unknown
Due 16 July 1993
Resolved 16 July 1993
Construction/Loadline
Issued 16 July 1993
Resolved
MAKE REPAIRS TO KNIFE EDGE PLATING AT BOTTOM OF WATERTIGHT DOOR IN UNUSED MESS DECK WHERE WASTED THROUGH.
Condition: Unknown
Due 16 July 1993
Resolved 16 July 1993
Lifesaving
Issued 16 July 1993
Resolved
REPAIR ON/OFF KNOB ON ONE SCBA AND ARRANGE REGULATOR PROPERLY ON OTHER SCBAIN STBD EMERGENCY FIREMAN'S LOCKER.
Condition: Unknown
Due 16 July 1993
Resolved 16 July 1993
Lifesaving
Issued 16 July 1993
Resolved
REPLACE CHEMICAL LIGHT ON TOP LIFE PRESERVER AT STBD DAVIT LAUNCHED RAFT STATION.
Condition: Unknown
Due 16 July 1993
Resolved 16 July 1993
Accommodation/Occupational Safety
Issued 16 July 1993
Resolved
INSTALL METALLIC HOSES ON DRYER VENTS.
Condition: Unknown
Due 16 July 1993
Resolved 16 July 1993
Engineering
Issued 16 July 1993
Resolved
PROVE PROPER OPERATION OF SIGHTGLASS SELF-CLOSING VALVES ON MAIN GENERATOR DAYTANK AND SETTLING TANK AND EMERGENCY GENERATOR DAYTANK.
Condition: Unknown
Due 16 July 1993
Resolved 16 July 1993
Electrical
Issued 16 July 1993
Resolved
ADJUST EMERGENCY GENERATOR OVERSPEED TO TRIP AT NOT MORE THAN 15% ABOVE RATED SPEED.
Condition: Unknown
Due 16 July 1993
Resolved 16 July 1993
Engineering
Issued 16 July 1993
Resolved
REPLACE FUEL OIL SUPPLY AND RETURN HOSES ON EMERGENCY GENERATOR.
Condition: Unknown
Due 16 July 1993
Resolved 16 July 1993
Accommodation/Occupational Safety
Issued 16 July 1993
Resolved
MAKE AVAILABLE FOR INTERNAL INSPECTION BULK AIR, START AIR, RIG AIR, AND DRILL FLOOR AIR RECEIVERS AND RESPECTIVE RELIEF VALVES FOR TESTING.
Condition: Unknown
Due 16 July 1993
Resolved 16 July 1993
Electrical
Issued 16 July 1993
Resolved
REPLACE CRACKED EYS FITTING AT EXPLOSION PROOF BOX FOR FAN/HTR ON DRILL FLOOR.
Condition: Unknown
Due 16 July 1993
Resolved 16 July 1993
Electrical
Issued 16 July 1993
Resolved
REPLACE MISSING EYS FITTINGS IN MUD PIT ROOM ELECTRICAL BOX UNDER PA SPEAKER.
Condition: Unknown
Due 16 July 1993
Resolved 16 July 1993
Electrical
Issued 16 July 1993
Resolved
REMOVE "SO" TYPE ELECTRICAL CABLE IN MUD PIT ROOM FORWARD BULKHEAD.
Condition: Unknown
Due 16 July 1993
Resolved 16 July 1993
Fire Fighting
Issued 16 July 1993
Resolved
SERVICE B-V FIRE EXTINGUISHERS IN MUDPUMP ROOM AND BY SHALE SHAKER HOUSE.
Condition: Unknown
Due 16 July 1993
Resolved 16 July 1993
Accommodation/Occupational Safety
Issued 16 July 1993
Resolved
REPLACE PRESSURE RELIEF VALVES ON SANITARY AND POTABLE WATER TANKS WITH ONES RATED EQUAL TO OR LESS THAN 100 PSI.
Condition: Unknown
Due 16 July 1993
Resolved 16 July 1993
Accommodation/Occupational Safety
Issued 16 July 1993
Resolved
REPLACE HOT WATER HEATER RELIEF VALVES (PRESSURE/TEMPERATURE) WITH ONES RATED AT OR BELOW 100 PSI AND AT OR BELOW 210 DEGREES FAHRENHEIT, OR OPEN TANKS FOR INTERNAL INSPECTION.
Condition: Unknown
Due 16 July 1993
Resolved 16 July 1993
Electrical
Issued 16 July 1993
Resolved
REPLACE AIR STARTER HOSE ON #3 MAIN GENERATOR.
Condition: Unknown
Due 16 July 1993
Resolved 16 July 1993
Electrical
Issued 16 July 1993
Resolved
REPLACE FUEL OIL RETURN HOSE ON #2 MAIN GENERATOR.
Condition: Unknown
Due 16 July 1993
Resolved 16 July 1993
Fire Fighting
Issued 22 July 1992
Resolved
FREE-UP AND PROPERLY MARK ALL FIRE DAMPERS FORWARD OF AND ON TOP OF THE HOUSE.
Condition: Unknown
Due 1 August 1992
Resolved 10 August 1992
Engineering
Issued 22 July 1992
Resolved
PLACE A "DEAD MAN" NOZZLE ON THE CEMENTING UNIT REFUELING HOSE.
Condition: Unknown
Due 1 August 1992
Resolved 10 August 1992
Electrical
Issued 22 July 1992
Resolved
REPAIR EMERGING BATTERY POWERED LIGHTS IN THE ENGINEER'S OFFICE, MUD PUMP ROOM AFT, AND WELD SHOP.
Condition: Unknown
Due 1 August 1992
Resolved 10 August 1992
Electrical
Issued 22 July 1992
Resolved
INSTALL BLANK OR SPARE BREAKER IN LIGHT PANEL LCII.
Condition: Unknown
Due 1 August 1992
Resolved 10 August 1992
Fire Fighting
Issued 22 July 1992
Resolved
PROPERLY MOUNT FIRE EXTINGUISHER #31 IN THE STBD GALLEY.
Condition: Unknown
Due 1 August 1992
Resolved 10 August 1992
Lifesaving
Issued 22 July 1992
Resolved
REPLACE FADED LIFESAVING PLAN IN THE MAIN DECK CORRIDOR.
Condition: Unknown
Due 1 August 1992
Resolved 10 August 1992
Electrical
Issued 22 July 1992
Resolved
REPLACE MISSING GLOBES ON LIGHTS IN LINEN LOCKER ON SECOND DECK.
Condition: Unknown
Due 1 August 1992
Resolved 10 August 1992
Lifesaving
Issued 1 August 1991
Resolved
Missing portable ladder for each lifeboat/capsule (2)._x001C_ _x001C_ _x001C_ _x001C_
Condition: Unknown
Due 1 August 1991
Resolved 1 August 1991
Lifesaving
Issued 15 August 1989
Resolved
CONDUCT WEIGHT TEST ON THE PORT AND STARBOARD LIFE-CAPSULES AND PROVIDE DOCUMENTATION OF SUBJECT TEST.
Condition: Unknown
Due 15 August 1989
Resolved 15 August 1989
Electrical
Issued 15 August 1989
Resolved
TEST AND CALIBRATE ALL HYDROGEN SULFIDE GAS PROBES LOCATED IN ALL CLAS- SIFIED LOCATIONS, PROVIDE DOCUMENTATION OF OF SUBJECT TEST.
Condition: Unknown
Due 15 August 1989
Resolved 15 August 1989
Unknown
Issued 26 July 1988
Resolved
PROVIDE IN DATE LIGHTS FOR SURVIVAL SUITS AS NECESSARY.
Condition: Unknown
Due 26 July 1988
Resolved 26 July 1988
Unknown
Issued 26 July 1988
Resolved
PROVIDE IN DATE LIGHTS FOR LIFE JACKETS AS NECESSARY.
Condition: Unknown
Due 26 July 1988
Resolved 26 July 1988
Unknown
Issued 26 July 1988
Resolved
ADD RETROREFLECTIVE MATERIAL FOR ALL LIFE JACKETS AND SURVIVAL SUITS.
Condition: Unknown
Due 26 July 1988
Resolved 26 July 1988
Unknown
Issued 26 July 1988
Resolved
PROVIDE AN IN DATE CERTIFICATE OF FINANCIAL RESPONSIBILITY.
Condition: Unknown
Due 26 July 1988
Resolved 26 July 1988
Unknown
Issued 26 July 1988
Resolved
POST AN EQUIPMENT LIST FOR STARBOARD LIFEBOAT (LIFEBOAT #2).
Condition: Unknown
Due 26 July 1988
Resolved 26 July 1988
Unknown
Issued 26 July 1988
Resolved
SERVICE 3 EACH AIR BOTTLES ON LIFEBOAT NO. 2.
Condition: Unknown
Due 26 July 1988
Resolved 26 July 1988
Unknown
Issued 26 July 1988
Resolved
PROVIDE A BOARDING LADDER FOR LIFEBOAT NO. 2.
Condition: Unknown
Due 26 July 1988
Resolved 26 July 1988
Unknown
Issued 26 July 1988
Resolved
REPLACE CONDENSED MILK ON LIFEBOAT NO. 2.
Condition: Unknown
Due 26 July 1988
Resolved 26 July 1988
Unknown
Issued 26 July 1988
Resolved
PROVIDE U.S. COAST GUARD APPROVED FIRST AID KIT FOR LIFEBOAT NO. 2.
Condition: Unknown
Due 26 July 1988
Resolved 26 July 1988
Unknown
Issued 26 July 1988
Resolved
SERVICE ONE AIR BOTTLE FOR LIFEBOAT NO. 1.
Condition: Unknown
Due 26 July 1988
Resolved 26 July 1988
Accommodation/Occupational Safety
Issued 14 September 1987
Resolved
MAKE OPERABLE THE MARINE SANITATION DEVICE FOR THE RIG.
Condition: Unknown
Due 14 September 1987
Resolved 14 September 1987
Deck/Cargo
Issued 14 September 1987
Resolved
PROVIDE EVIDENCE OF ANNUAL SERVICE INSPECTION FOR STAARBOARD FORWARD CRANE AT FRAME 6.
Condition: Unknown
Due 14 September 1987
Resolved 14 September 1987
Lifesaving
Issued 14 September 1987
Resolved
DAVIT LAUNCHED INFLATABLE LIFERAFTS TO BE PROPERLY SET-UP AND MADE READY FOR OPERATION AND INSTRUCTIONS POSTED, ONE PER RAFT. INSURE FLOAT FREE ARRANGEMENT IS MAINTAINED.
Condition: Unknown
Due 14 September 1987
Resolved 14 September 1987
Lifesaving
Issued 14 September 1987
Resolved
REPLACE BROKEN WINDOW IN BOTH LIFEBOATS.
Condition: Unknown
Due 14 September 1987
Resolved 14 September 1987
Construction/Loadline
Issued 14 September 1987
Resolved
REPAIR OR REPLACE BROKEN DOGS ON DECK HATCH COVERS LOCATED STARBOARD SIDE AMIDSHIP.
Condition: Unknown
Due 14 September 1987
Resolved 14 September 1987
Deck/Cargo
Issued 14 September 1987
Resolved
REPLACE BROKEN DOGGING GEAR AND THOSE SHOWING EVIDENCE OF NECKING DOWN OR BULK STORAGE TANKS.
Condition: Unknown
Due 14 September 1987
Resolved 14 September 1987