Records from 1983 to 2003. Most recent: inspection, 29 December 2003.
A report is not offered for this hull: Its record holds only 2 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. Reports.
Inspection history · 44
29 December 2003
Security Plan Review - VSP
Administrative · Marine Safety Center (MSC) · Activity 1971436
23 April 2003
COI Inspection · Hull Examination · Internal Structural Exam
Physical examination · Activities Europe · Activity 1732875
14 March 2002
Annual Inspection
Physical examination · Activities Europe · Activity 1483594
4 July 2001
Hull Examination · Re-Inspection
Physical examination · Activities Europe · Activity 1362330
3 May 2000
COI Inspection
Physical examination · Activities Europe · Activity 1440309
5 July 1999
Re-Inspection
Physical examination · Activities Europe · Activity 1131569
29 May 1998
Hull Examination · COI Inspection
Physical examination · Activities Europe · Activity 1368782
16 June 1997
Re-Inspection
Physical examination · Activities Europe · Activity 777372
8 April 1997
Administrative
Administrative · Activities Europe · Activity 1097473
10 August 1996
Hull Examination
Physical examination · Activities Europe · Activity 1354000
30 April 1996
COI Inspection
Physical examination · Activities Europe · Activity 1083239
12 October 1994
Deficiency Check
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 870265
12 July 1994
Deficiency Check
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 865875
28 April 1994
COI Inspection · MARPOL Annex V Examination
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1171707
1 March 1994
Deficiency Check
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1165134
5 August 1993
Administrative
Administrative · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 846686
2 July 1993
Hull Examination
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 847748
21 January 1993
Re-Inspection
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1149230
17 April 1992
Deficiency Check
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 958163
3 March 1992
COI Inspection
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1263912
18 October 1991
Deficiency Check
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1247743
15 October 1991
Deficiency Check
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 941259
26 July 1991
Hull Examination
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1311003
11 February 1991
Re-Inspection
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1249561
11 February 1991
Administrative
Administrative · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1312611
17 January 1991
Type not recorded
No type recorded · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 934942
7 January 1991
Administrative
Administrative · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1214478
18 December 1990
Type not recorded
No type recorded · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 928620
16 May 1990
Administrative
Administrative · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1237071
25 April 1990
Administrative
Administrative · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1216435
5 March 1990
COI Inspection
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1223144
25 February 1989
Re-Inspection
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1200338
10 January 1989
Administrative
Administrative · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 887091
10 December 1988
Hull Examination
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1037275
9 February 1988
COI Inspection
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1328580
25 September 1987
Re-Inspection
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1017792
25 September 1987
MARPOL Annex II Examination
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1326643
20 July 1986
Credit Drydock
Administrative · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1305328
20 February 1986
COI Inspection
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1295025
17 January 1986
Type not recorded
No type recorded · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1307505
10 January 1984
Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1279984
23 December 1983
Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 971291
14 April 1983
Type not recorded
No type recorded · MSO Mobile · USCG Heartland District (CGD-H) · Activity 963568
14 April 1983
Type not recorded
No type recorded · MSO Mobile · USCG Heartland District (CGD-H) · Activity 969653
Personnel › Certificates/Documents/Licenses
Issued 2 July 2003
Resolved
[withheld — contains personal information; the deficiency system, dates, and resolution status are shown above]
Condition: Placed in Improper Service
Due 2 August 2003
Resolved 11 August 2003
Electrical › Electrical Distribution System (service)
Issued 2 July 2003
Resolved
Repair motor controller for STBD engine room supply ventilation. LEGACY COMPONENT DESC: Switch
Condition: Placed in Improper Service
Due 2 July 2003
Resolved 2 July 2003
Electrical › Electrical Distribution System (service)
Issued 2 July 2003
Resolved
Repair motor controller for sewage pump. LEGACY COMPONENT DESC: Junction Box
Condition: Improper/Lack of Maintenance
Due 11 August 2003
Resolved 11 August 2003
Deck/Cargo › Cargo Transfer/Lightering (liquid)
Issued 2 July 2003
Resolved
Provide proof of Hydro for Cargo and Fuel transfer hoses. LEGACY COMPONENT DESC: Transfer Hose
Condition: Improper/Lack of Maintenance
Due 2 August 2003
Resolved 11 August 2003
Documentation › Safety Management System
Issued 2 July 2003
Resolved
Have annual hydro of cargo hoses and fuel transfer hoses placed on annual maintenance schedule and provide proof to [name withheld] DESC: Reports and Analysis Procedures
Condition: Improper Installation
Due 2 August 2003
Resolved 11 August 2003
Lifesaving › Lifejacket/PFD (General)
Issued 2 July 2003
Resolved
Post lifejacket donning instructions in accommodations spaces. LEGACY COMPONENT DESC: Instructions
Condition: Improper/Lack of Maintenance
Due 2 August 2003
Resolved 11 August 2003
Construction/Loadline › Structures › Longitudinal Bulkhead
Issued 2 July 2003
Resolved
Crop and insert 18" x 18" in way of #1 stbd ballast tank in way of frame #17.
Condition: Improper/Lack of Maintenance
Due 2 July 2003
Resolved 2 July 2003
Navigation › Piloting/Steering
Issued 2 July 2003
Resolved
Provide statement from Master stating vessel Compass deviation has been correctly updated. LEGACY COMPONENT DESC: Compass Deviation Table
Condition: Improper/Lack of Maintenance
Due 2 August 2003
Resolved 11 August 2003
Construction/Loadline › Hull › Transverse Frame
Issued 23 April 2003
Resolved
Crop and renew wasted aft bulkhead as marked in port aft peak tank to port aft void
Condition: Improper/Lack of Maintenance
Due 30 June 2003
Resolved 30 June 2003
Construction/Loadline › Structures
Issued 23 April 2003
Resolved
Crop and renew wasted sounding pipe in port aft peak tank LEGACY COMPONENT DESC: sounding pipe
Condition: Improper/Lack of Maintenance
Due 30 June 2003
Resolved 30 June 2003
Construction/Loadline › Structures
Issued 23 April 2003
Resolved
Crop and renew wasted bulkhead in engine room port side to void space in way of emergency escape and oily water separator. LEGACY COMPONENT DESC: Longitudinal Bulkhead
Condition: Improper/Lack of Maintenance
Due 30 June 2003
Resolved 30 June 2003
Construction/Loadline › Hull › Longitudinal Frame
Issued 23 April 2003
Resolved
Crop and renew wasted frames 15 and 16 in #1 stbd ballast tank.
Condition: Improper/Lack of Maintenance
Due 30 June 2003
Resolved 30 June 2003
Construction/Loadline › Hull
Issued 23 April 2003
Resolved
crop and renew wasted deck longs #23 and #27 in overhead of #2 stbd ballast tank. LEGACY COMPONENT DESC: Transverse Frame
Condition: Improper/Lack of Maintenance
Due 30 June 2003
Resolved 30 June 2003
Construction/Loadline › Structures
Issued 23 April 2003
Resolved
Crop and renew wasted bottom of exhaust trunking on stbd side from approximately frame #31 to #40. LEGACY COMPONENT DESC: Exhaust trunking
Condition: Improper/Lack of Maintenance
Due 30 June 2003
Resolved 30 June 2003
Construction/Loadline › Structures
Issued 23 April 2003
Resolved
Crop and renew wasted bottom of exhaust trunking on stbd side from approximately frame #56 to #60. LEGACY COMPONENT DESC: exhaust trunking
Condition: Improper/Lack of Maintenance
Due 30 June 2003
Resolved 30 June 2003
Construction/Loadline › Structures
Issued 23 April 2003
Resolved
Gouge and weld fracture on exhaust trunk in way of forward port bit approximately frame 38. LEGACY COMPONENT DESC: exhaust trunking
Condition: Improper/Lack of Maintenance
Due 30 June 2003
Resolved 30 June 2003
Engineering › Fuel Oil Service System › Gauge
Issued 23 April 2003
Resolved
Remove temporary sight glass on port fuel day tank and correctly pipe tank level indicator on both port and stbd side.
Condition: Improper Installation
Due 30 June 2003
Resolved 30 June 2003
Engineering › Fuel Oil Service System › Piping
Issued 23 April 2003
Resolved
Repair fuel oil leaks in piping to winch engine. ( in engine room above WTD.)
Condition: Improper/Lack of Maintenance
Due 27 July 2003
Resolved 1 July 2003
Construction/Loadline › Structures › Deck Plating
Issued 23 April 2003
Resolved
Crop and renew wasted overhead deck in #2 ballast tan at approximately frame 27.5 in way of stbd deck locker approx 2' x2' insert.
Condition: Improper/Lack of Maintenance
Due 30 June 2003
Resolved 30 June 2003
Electrical › Electrical Distribution System (service)
Issued 23 April 2003
Resolved
Repair loose wires to motor controllers in bow thruster space. Wires are loose into the bottoms of boxes and need to be properly secured. LEGACY COMPONENT DESC: Wiring
Condition: Improper/Lack of Maintenance
Due 27 July 2003
Resolved 1 July 2003
Construction/Loadline › Structures › Longitudinal Bulkhead
Issued 23 April 2003
Resolved
Crop and renew wasted centerline bulkhead in #2 ballast tank between frame 27-29.
Condition: Improper/Lack of Maintenance
Due 30 June 2003
Resolved 30 June 2003
Accommodation/Occupational Safety › Occupational Safety
Issued 23 April 2003
Resolved
Provide copy of ultrasonic thickness readings taken by Global Marine. LEGACY COMPONENT DESC: UT reports
Condition: Unknown
Due 27 July 2003
Resolved 1 July 2003
Deck/Cargo › Mooring/Anchoring
Issued 23 April 2003
Resolved
Crop and renew wasted area in Stbd hawser pipe. LEGACY COMPONENT DESC: Hawser Pipe
Condition: Improper/Lack of Maintenance
Due 30 June 2003
Resolved 30 June 2003
Electrical › Lighting (service) › Lighting Feeder
Issued 23 April 2003
Resolved
Repair wire to light fixture in Stbd anchor chain locker.
Condition: Improper/Lack of Maintenance
Due 27 July 2003
Resolved 1 July 2003
Lifesaving › Launching Appliances › Davit
Issued 23 April 2003
Resolved
Provide suitable davit and engine for rescue boat as outlined in EURMI policy letter dated 07 Feb 02. (Copy left with Vessel)
Condition: Damaged By Earlier Event
Due 30 June 2003
Resolved 30 June 2003
Construction/Loadline › Structures
Issued 23 April 2003
Resolved
Aft main deck is holed and wasted beyond allowable limits. stbd side of centerline is to cropped and renewed from frame 40 to stern. LEGACY COMPONENT DESC: Deck Plating
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 30 June 2003
Resolved 30 June 2003
Construction/Loadline › Structures
Issued 23 April 2003
Resolved
Aft main deck port side of centerline is to be cropped and renewed from frame 49 to stern. LEGACY COMPONENT DESC: Deck Plating
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 30 June 2003
Resolved 30 June 2003
Construction/Loadline › Structures › Deck Plating
Issued 23 April 2003
Resolved
Ultrasonic reading are to be taken on aft main deck area from frame 40 to 44 from centerline to port side and provide to MIO Europe for further evaluation.
Condition: Improper/Lack of Maintenance
Due 30 June 2003
Resolved 30 June 2003
Lifesaving › Lifeboat Equipment
Issued 23 April 2003
Resolved
Provide proof of EPIRB registration. LEGACY COMPONENT DESC: Radar Transponder
Condition: Improper/Lack of Maintenance
Due 2 August 2003
Resolved 11 August 2003
Fire Fighting › Fire Pumps
Issued 23 April 2003
Resolved
Repair leaking fire pump discharge valve. LEGACY COMPONENT DESC: Valves
Condition: Improper Installation
Due 2 August 2003
Resolved 11 August 2003
Electrical › Lighting (emergency)
Issued 6 March 2002
Resolved
Port and starboard liferaft embarkation lights not operational. Trouble shot, repair, and prove proper operation of embarkation lights. LEGACY COMPONENT DESC: Lighting Fixture
Condition: Improper/Lack of Maintenance
Due 21 March 2002
Resolved 19 March 2002
Communications › Radio Communications
Issued 6 March 2002
Resolved
EPIRB NOT OPERATIONAL LEGACY COMPONENT DESC: EPIRB
Condition: Unknown
Action required: 17 - Rectify deficiencies prior to departure
Due 14 September 2002
Resolved 14 March 2002
Resolution: substitute EPRIB placed onboard
Lifesaving › Lifebuoys
Issued 6 March 2002
Resolved
Properly afix retro-reflective tape to ringbouys.
Condition: Improper/Lack of Maintenance
Due 21 March 2002
Resolved 19 March 2002
Resolution: received fax from the vessel master stating item corrected.
Electrical › Lighting (service)
Issued 6 March 2002
Resolved
Side screens missing from stern light. Provide proper screens for stern lights. LEGACY COMPONENT DESC: Lighting Fixture
Condition: Improper Installation
Due 21 September 2002
Resolved 19 March 2002
Resolution: replaced
Construction/Loadline
Issued 3 May 2000
Resolved
Prove proper operation of both engineroom watertight hatches, loacted on the weather deck. Hinges, locking mechanism, wasted steel trunk, bent covers etc. This item shall be completed prior to vsl sailing.
Condition: Unknown
Due 15 May 2000
Resolved 15 May 2000
Fire Fighting
Issued 3 May 2000
Resolved
Provide proper international shore connection.
Condition: Unknown
Due 14 June 2000
Resolved 14 June 2000
Engineering
Issued 3 May 2000
Resolved
Install proper CG approved relief valves on both enginerrom air receivers.
Condition: Unknown
Due 14 June 2000
Resolved 14 June 2000
Engineering
Issued 29 May 1998
Resolved
PROVIDE ONBOARD PROPER "UV" TYPE PRESSURE VESSEL RELIEF VALVES FOR PORT ANDSTBD ENGINE ROOM AIR RECIEVERS.
Condition: Unknown
Due 30 June 1998
Resolved 30 June 1998
Documentation
Issued 29 May 1998
Resolved
[withheld — contains personal information; the deficiency system, dates, and resolution status are shown above]
Condition: Unknown
Due 30 June 1998
Resolved 30 June 1998
Documentation
Issued 30 April 1996
Resolved
PROVIDE ON BOARD ONE GARBAGE PLAN AND PLACARD.
Condition: Unknown
Due 1 July 1996
Resolved 23 May 1996
Engineering
Issued 30 April 1996
Resolved
RENEW PRESSURE RELIEF VALVE ON PORT ENGINE ROOM AIR RECIEVER WITH PROPER ASME "UV" TYPE 200 PSI VALVE.
Condition: Unknown
Due 1 July 1996
Resolved 23 May 1996
Lifesaving
Issued 30 April 1996
Resolved
RENEW OR SERVICE OUTDATED EPIRB HYDROSTATIC RELEASE.
Condition: Unknown
Due 30 April 1996
Resolved 30 April 1996
Fire Fighting
Issued 28 April 1994
Resolved
HYDRO TEST ALL PORTABLE CO2 FIRE EXTINQUISHERS, OR PROVIDE DOCUMENTATION THAT VERIFY PORTABLE CO2 EXTINQUISHER HYDRO OF 2/91 WAS CONDUCTED BY AUTHORIZED U.S. DOT FACILITY.
Condition: Unknown
Due 28 April 1994
Resolved 28 April 1994
Unknown
Issued 28 April 1994
Resolved
PROVIDE HAND RELEAVING DEVICE FOR (2) BULK TANKS RELIEF VALVES.
Condition: Unknown
Due 28 April 1994
Resolved 28 April 1994
Fire Fighting
Issued 21 January 1993
Resolved
PROVE PROPER OPERATION OF FIRE SYSTEM PRESSURE GAUGE AT FWD PILOT HOUSE._x001C_ _x001C_ _x001C_ _x001C_
Condition: Unknown
Due 21 January 1993
Resolved 21 January 1993
Navigation
Issued 21 January 1993
Resolved
REPAIR/REPLACE GYRO REPEATER AND PROVE PROPER OPERATION._x001C_ _x001C_ _x001C_ _x001C_
Condition: Unknown
Due 21 January 1993
Resolved 21 January 1993
Electrical
Issued 21 January 1993
Resolved
REPLACE FAULTY RPM GAUGES FOR BOTH SHIP SERVICE DIESEL GENERATORS._x001C_ _x001C_ _x001C_ _x001C_
Condition: Unknown
Due 21 January 1993
Resolved 21 January 1993
Construction/Loadline
Issued 21 January 1993
Resolved
MAKE PERMANENT REPAIRS TO WASTED BILGE/BALLAST PIPING ON DISCHARGE SIDE OF PUMP IN ENGINE ROOM._x001C_ _x001C_ _x001C_
Condition: Unknown
Due 21 January 1993
Resolved 21 January 1993
Engineering
Issued 21 January 1993
Resolved
PROVE PROPER OPERATION OF BOTH MAIN DIESEL ENGINE LUBE OIL SHUTDOWNS/ALARMS._x001C_ _x001C_ _x001C_
Condition: Unknown
Due 21 January 1993
Resolved 21 January 1993
Engineering
Issued 21 January 1993
Resolved
REPAIR OIL LEAK PORT MAIN DIESEL ENGINE EXHAUST PIPING AND REPLACE OIL SOAKED EXHAUST LAGGING._x001C_ _x001C_ _x001C_
Condition: Unknown
Due 21 January 1993
Resolved 21 January 1993
Navigation
Issued 21 January 1993
Resolved
PROVIDE DEVIATION TABLE._x001C_ _x001C_ _x001C_ _x001C_
Condition: Unknown
Due 21 January 1993
Resolved 21 January 1993
Electrical
Issued 21 January 1993
Resolved
PROVE PROPER OPERATION OF ELECTRICAL SWITCH BOARD SLIDE BAR TO PREVENT BOTHGENERATOR CIRCUIT BREAKERS FROM BEING ENERGIZED AT THE SAME TIME._x001C_ _x001C_ _x001C_
Condition: Unknown
Due 21 January 1993
Resolved 21 January 1993
Deck/Cargo
Issued 21 January 1993
Resolved
REPLACE 3 OF THE DRY MUD TANK RELIEF VALVES THAT HAVE 1 1/2" INLET. INLET MUST BE 2"._x001C_ _x001C_ _x001C_
Condition: Unknown
Due 21 January 1993
Resolved 21 January 1993
Fire Fighting
Issued 21 January 1993
Resolved
SERVICE PORTABLE ENGINEROOM. FIRE EXTINGUISHERS #6 & #7, AND HYDRO PAINT LOCKER FIRE EXTINGUISHER._x001C_ _x001C_ _x001C_
Condition: Unknown
Due 21 January 1993
Resolved 21 January 1993
Engineering
Issued 21 January 1993
Resolved
REPLACE ERODED EMERGENCY ELECTRICAL SHUTDOWN SWITCH ON STBD DECK FOR FUEL/OIL TRANSFER PUMP._x001C_ _x001C_ _x001C_
Condition: Unknown
Due 21 January 1993
Resolved 21 January 1993
Navigation
Issued 21 January 1993
Resolved
REPAIR/REPLACE STARBOARD RADAR AND PROVE PROPER OPERATION._x001C_ _x001C_ _x001C_ _x001C_
Condition: Unknown
Due 21 January 1993
Resolved 21 January 1993
Navigation
Issued 3 March 1992
Resolved
MAKE PERMANENT REPAIRS TO ENGINE ROOM STEERING GEAR RUDDER DIRECTION INDICATOR.
Condition: Unknown
Due 29 April 1992
Resolved 29 April 1992
Electrical
Issued 3 March 1992
Resolved
MAKE PERMANENT REPAIRS TO PORT AND STARBOARD S/S GENERATORS TACHOMETERS.
Condition: Unknown
Due 29 April 1992
Resolved 29 April 1992
Fire Fighting
Issued 15 October 1991
Resolved
PROVIDE ANNUAL SERVICING FOR ALL PORTABLE FIRE EXTINGUISHERS.
Condition: Unknown
Due 15 October 1991
Resolved 15 October 1991
Fire Fighting
Issued 11 February 1991
Resolved
REPLACE FIRE PUMP GAUGE LOCATED IN ENGINE ROOM.
Condition: Unknown
Due 30 August 1991
Resolved 30 August 1991
Fire Fighting
Issued 11 February 1991
Resolved
PROVIDE ANNUAL SERVICING FOR ALL PORTABLE FIRE EXTINGUISHERS.
Condition: Unknown
Due 11 February 1991
Resolved 11 February 1991
Fire Fighting
Issued 11 February 1991
Resolved
PROVIDE TWO (02) DOT APPROVED AIR BOTTLES FOR SELF-CONTAINED BREATHING APPARATUS LOCATED ON BRIDGE.
Condition: Unknown
Due 11 February 1991
Resolved 11 February 1991
Lifesaving
Issued 11 February 1991
Resolved
REPLACE BATTERY FOR EPIRB.
Condition: Unknown
Due 9 September 1991
Resolved 9 September 1991
Fire Fighting
Issued 11 February 1991
Resolved
PROVIDE ONE ADDITIONAL SELF-CONTAINED BREATHING APPARATUS IN ACCORDANCE WITH 46CFR 96-35-10.
Condition: Unknown
Due 11 February 1991
Resolved 11 February 1991
Lifesaving
Issued 11 February 1991
Resolved
PROVIDE TWO (02) COAST GUARD APPROVED SMOKE SIGNALS FOR RING LIFE BUOYS IN ACCORDANCE WITH 46 CFR 94.43-5.
Condition: Unknown
Due 11 February 1991
Resolved 11 February 1991
Documentation
Issued 11 February 1991
Resolved
PROVIDE CURRENT TIDE TABLES AND RULES OF THE ROAD.
Condition: Unknown
Due 11 February 1991
Resolved 11 February 1991
Fire Fighting
Issued 5 March 1990
Resolved
HAVE HYDROSTATICALLYTESTED ALL PORTABLE 15 LB CO2 & PAINT LOCKER 15 LB CO2 BOTTLES OR REPLACE SAME AT ADOT APPROVED FACILITY.
Condition: Unknown
Due 5 March 1990
Resolved 5 March 1990
Lifesaving
Issued 5 March 1990
Resolved
REPLACE ALL OUT DATED HANDHELD RED FLARES AND LINE THROWING GUN CARTRIDGES.
Condition: Unknown
Due 5 March 1990
Resolved 5 March 1990
Lifesaving
Issued 5 March 1990
Resolved
REPLACE ALL OUT DATED LIFE PRESERVER LIGHTS AND FIX (3) THREE BUCKLES.
Condition: Unknown
Due 5 March 1990
Resolved 5 March 1990
Fire Fighting
Issued 5 March 1990
Resolved
HAVE SERVICED ALL PORTABLE FIRE EXTINGUISHERS ON BOARD.
Condition: Unknown
Due 5 March 1990
Resolved 5 March 1990
Electrical
Issued 5 March 1990
Resolved
HAVE PORT & STBD BRIDGE EMERGENCY BATTERY BOXES LINED WITH LEAD OR FIBERGLASS AND INSTALL FLAME SCREENS ON VENTS.
Condition: Unknown
Due 5 March 1990
Resolved 5 March 1990
Documentation
Issued 5 March 1990
Resolved
OBTAIN FOR VESSEL COPIES OF 46 CFR SUBCHAPTERS I, F & E.
Condition: Unknown
Due 5 March 1990
Resolved 5 March 1990
Engineering
Issued 10 December 1988
Resolved
MAKE PERMANENT REPAIRS TO FOWARD PEAK TANK BILGE SUCTION VALVE REACH ROD. WHEN REPAIRS ARE COMPLETE THE MASTER MUST INFORM THE [name withheld] LETTER.
Condition: Unknown
Due 10 December 1988
Resolved 10 December 1988
Unknown
Issued 23 December 1983
Resolved
THE FOLLOWING DEFICIENCY PERTAIN TO THE VESSEL LODRIGUE TIDE DN655327.
Condition: Unknown
Due 23 December 1983
Resolved 23 December 1983
Unknown
Issued 23 December 1983
Resolved
(REQUIREMENTS D-1 CONTINUED) FRAMES AND THE DETALS SHOWING DECK PLATE PENETRATION FOR THE TOW PIN BOX.
Condition: Unknown
Due 23 December 1983
Resolved 23 December 1983
Construction/Loadline
Issued 23 December 1983
Resolved
PROVIDE STRUCTURAL DRAWINGS SHOWING THE TOW PIN INSTALLATION. THESE DRAW- INGS CONTAIN WELDING DETAILS SHOWING TOW PIN BOX CONNECTION TO EXISTING
Condition: Unknown
Due 23 December 1983
Resolved 23 December 1983
Deck/Cargo
Issued 14 April 1983
Resolved
PRIOR TO UTILIZING THE VESSEL'S LIQUID MUD SYSTEM AND IN ANY EVENT NOT LATER THAN 14 MAY 1983, SUBMIT "AS BUILT" PLANS OF THE LIQUID MUD AND FUEL
Condition: Unknown
Due 14 April 1983
Resolved 14 April 1983
Deck/Cargo
Issued 14 April 1983
Resolved
SUBMIT TO COGNIZANT OFFICER IN CHARGE, MARINE INSPECTION, UPDATED FUEL OIL AND LIQUID MUD OIL TRANSFER PROCEDURES AS APPLICABLE.
Condition: Unknown
Due 14 April 1983
Resolved 14 April 1983
Deck/Cargo
Issued 14 April 1983
Resolved
UNAUTHORIZED MODIFICATIONS MADE TO EXISTING LIQUID MUD AND FUEL PIPING SYSTEMS WHICH ALLOW INTERCONNECTION OF THE SYSTEMS FOR THE PURPOSE OF
Condition: Unknown
Due 14 April 1983
Resolved 14 April 1983
Deck/Cargo
Issued 14 April 1983
Resolved
PRIOR TO UTILIZING THE VESSEL'S LIQUID MUD SYSTEM ALL REVISED INSTALLATIONSSHALL BE TO THE SATISFACTION OF THE COGNIZANT OFFICER IN CHARGE MARINE
Condition: Unknown
Due 14 April 1983
Resolved 14 April 1983