SAFARI ROSE is a 1959 passenger vessel (inspected). The Coast Guard has recorded 74 inspections since 1985, most recently in July 2025, along with 140 deficiencies, 1 operational control and 2 casualty investigations between 2003 and 2017.

Records from 1985 to 2025. Most recent: inspection, 11 July 2025.

Built
1959
Last inspected
11 July 2025
Documentation
Valid · documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

WDE5075
Flag
UNITED STATES
367361710 (licence lapsed)
Maury page id
psix-54844

Inspections, by type

…with no type recorded8
Years with a record 36 calendar years (1985–2025)
The 74 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 1977.

Documentation record

Registered dimensions (L × B × D)71.5 ft × 18.5 ft × 8.9 ft
Registered tonnagegross 90 / net 61
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderALLIED MARINE CORPORATION · MIAMI, FL, UNITED STATES · built 1959
Hull materialWood
PropulsionDiesel Reduction
Hull shapeNot recorded
Hull configurationNot recorded
Hailing portzephyr cove, NV
Trade endorsementsCoastwise, unrestricted, Fishery, Recreational
DocumentationValid · issued 14 January 2026 · expires 31 January 2027
Service, as the file records itPassenger (Inspected)
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it90 - Regulatory (Subpart C or D), Gross Ton
61 - Regulatory (Subpart C or D), Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 September 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.

Radio station licence

WDE5075MMSI 367361710 · expired · compulsorily equipped · granted 7 June 2008, cancelled 11 August 2018
WCX8708MMSI not assigned · expired · voluntarily equipped · granted 4 December 1997, cancelled 9 February 2008 · licensed under a name not among this hull’s recorded names (not shown)
FCC Universal Licensing System ship-station file of 6 September 2026, matched to this hull on its US Official Number. Status and dates are the file’s own. The licensee is not read from the file and is not shown. A lapsed licence’s MMSI is still the number the vessel transmitted under while it was valid.

Inspection history · 74

11 July 2025 COI Inspection · Deficiency Check
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 8168911
5 May 2022 Annual Inspection · Administrative Inspection
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 7449438
28 April 2021 Annual Inspection · Deficiency Check
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 7173963
6 August 2020 Internal Structural Exam · Annual Inspection
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 7021892
16 May 2019 COI Inspection · Administrative Inspection · Deficiency Check
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 6681438
5 August 2018 Internal Structural Exam · Annual Inspection · Administrative Inspection
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 6501229
1 September 2017 Type not recorded
No type recorded · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 6282029
25 July 2017 Annual Inspection · DAPI Audit
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 6216750
6 June 2017 Drydock Exam · Administrative Inspection · Internal Structural Exam
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 6166259
10 May 2017 Internal Structural Exam · Drydock Extension
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 6146556
30 July 2016 Administrative Inspection
Administrative · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 5962794
22 July 2016 Internal Structural Exam · Drydock Extension
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 5949750
9 June 2016 Annual Inspection
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 5907343
7 May 2012 Administrative Inspection · Annual Inspection
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 4304974
22 July 2011 Deficiency Check · DAPI Audit
Physical examination · USCG Southwest District (dp) · USCG Southwest District (CGD-SW) · Activity 4098493
5 March 2010 Administrative Inspection
Administrative · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 3690707
4 May 2009 Drydock Exam
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 3465450
13 April 2009 COI Inspection · Drydock Extension
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 3450281
2 February 2009 Drydock Extension
Administrative · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 3415980
10 June 2008 Annual Inspection
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 3228017
20 March 2007 Annual Inspection
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 2889100
3 May 2006 Annual Inspection · Deficiency Check
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 2639873
5 May 2005 Annual Inspection
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 2353428
7 April 2004 Deficiency Check · COI Inspection
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 2039300
2 March 2004 Plan Review "T" Boat
Administrative · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 2016542
13 December 2003 Deficiency Check
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1964306
14 November 2003 Administrative Inspection
Administrative · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1947770
27 October 2003 Plan Review "T" Boat
Administrative · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1937298
22 July 2003 Deficiency Check · Examination of Repairs · Plan Review "T" Boat · Damage Survey
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1887008
17 July 2003 Type not recorded
No type recorded · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1853112
17 July 2003 Type not recorded
No type recorded · Station Lake Tahoe · USCG Southwest District (CGD-SW) · Activity 1906305
25 June 2003 Deficiency Check · Administrative Inspection · Inclining Experiment
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1785393
15 April 2003 Hull Examination
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1772259
5 August 2002 COI Inspection
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1657000
14 November 2001 Re-Inspection
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1625805
15 August 2000 Re-Inspection
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1436440
13 April 2000 Hull Examination
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1369608
22 September 1999 Deficiency Check
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1340395
30 August 1999 COI Inspection
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1361083
30 September 1998 Re-Inspection
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1421561
1 October 1997 Re-Inspection
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1462596
17 September 1996 Administrative
Administrative · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1270556
1 August 1996 COI Inspection
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1402280
20 June 1996 Deficiency Check
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1242092
28 March 1996 Deficiency Check
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1402213
9 August 1995 Hull Examination
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 774154
9 August 1995 COI Inspection · Hull Examination
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1400221
17 October 1994 Damage Survey
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1440872
24 September 1994 Type not recorded
No type recorded · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 70397
15 August 1994 Administrative
Administrative · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1177127
29 July 1994 Deficiency Check
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1171939
24 May 1994 COI Inspection
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1409136
12 July 1993 Deficiency Check
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1155533
24 June 1993 Deficiency Check
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1154031
17 June 1993 COI Inspection
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1134720
17 May 1993 Type not recorded
No type recorded · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1373856
24 August 1992 Administrative
Administrative · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 949525
10 July 1992 Deficiency Check
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 946484
25 June 1992 COI Inspection
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1266630
17 March 1992 Hull Examination
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 960110
20 December 1991 Drydock Extension
Administrative · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 961117
26 September 1991 Administrative
Administrative · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1245597
9 August 1991 Type not recorded
No type recorded · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1250386
28 June 1991 COI Inspection
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1247680
13 June 1991 Administrative
Administrative · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1327106
25 October 1990 Type not recorded
No type recorded · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 912775
29 June 1990 Hull Examination · COI Inspection
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 928604
5 March 1990 Administrative
Administrative · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 921011
6 March 1989 COI Inspection
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 890687
5 April 1988 COI Inspection
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1301288
17 March 1987 COI Inspection
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1016078
17 March 1987 Hull Examination
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1016080
10 March 1986 COI Inspection
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1299143
15 March 1985 Type not recorded
No type recorded · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1288331

Deficiency record · 140

07 - Fire Safety › N/A - No Subsystem › Fire pumps and its pipes
Issued 11 July 2025 Resolved
On a vessel of more than 65 feet in length, the minimum capacity of the fire pump must be 50 gpm at a pressure of not less than 60 psi. Fire pump gauge read max of 25 psi during testing. 46 CFR 181.300
Condition: Invalid
Action required: 50 - Rectify deficiencies w/in 30 days
Due 11 August 2025
Resolved 25 August 2025
Resolution: Witnessed satisfactory test of fire pump. Pressure was above 60psi.
07 - Fire Safety › N/A - No Subsystem › Fixed fire extinguishing installation
Issued 11 July 2025 Resolved
A distribution line must extend at least 2" beyond the last orifice and be closed with a cap or plug. Distribution line nearest bottles terminates with discharge horn and is missing 2" piping addition. 46 CFR 181.410
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 11 August 2025
Resolved 4 August 2026
Resolution: Verified correction.
07 - Fire Safety › N/A - No Subsystem › Fire pumps and its pipes
Issued 11 July 2025 Resolved
At each inspection for certification, the owner must be prepared to conduct tests and have the vessel ready for inspection of its fire protection equipment, including the following: operation of the fire main system. Fire main valve in the engine room leaks approximately 1 drop per second when running. 46 CFR 176.810
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 25 July 2025
Resolved 28 July 2025
Resolution: Accepted video of correction.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 11 July 2025 Resolved
At each inspection for certification of a vessel, the owner shall be prepared to conduct tests and have the vessel ready for inspections of machinery, including the following: Operational test of the means provided for pumping bilges. Bilge pump float switch beneath galley is mounted on a board that allows it to float with rising water. Secure float to the bilge area. 46 CFR 176.804
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 25 July 2025
Resolved 28 July 2025
Resolution: Accepted photo for correction.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Operation of machinery
Issued 11 July 2025 Resolved
At each inspection for certification of a vessel, the owner shall be prepared to conduct tests and have the vessel ready for inspections of machinery, including the following: operation of the main propulsion machinery. Starboard shaft has a continious leak when main engines are off and vessel is idle. 46 CFR 176.804
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 25 July 2025
Resolved 28 July 2025
Resolution: Accepted video of correction.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 11 July 2025 Resolved
All wiring and cables shall be suitable for marine service and the particular installation used. Live, dead end wires found in lazarette on forward bulkhead beneath hydraulic oil tank and on upper weatherdeck inside old control station. 46 CFR 183.10-20
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 25 July 2025
Resolved 28 July 2025
Resolution: Accepted photo of correction.
08 - Alarms › N/A - No Subsystem › Other (alarms)
Issued 11 July 2025 Resolved
At each inspection for certification of a vessel, the owner shall be prepared to conduct tests and have the vessel ready for inspections of machinery, including the following: test of machinery alarms including bilge high level alarms. Lazarette and forepeak high level alarm float switches stick in the raised position and do not operate as designed. 46 CFR 176.804
Condition: Design Flaw
Action required: 16 - Rectify deficiencies w/in 14 days
Due 25 July 2025
Resolved 28 July 2025
Resolution: Accepted video of correction.
09 - Working and Living Conditions › 092 - Working Conditions › Safe means of access
Issued 11 July 2025 Resolved
On a vessel on which the number of passengers permitted on upper decks is limited by stability criteria, the max number of passengers allowed on an upper deck must be indicated by a durable marking of at least 1" numbers and letters at the entranceway to that deck. Second deck passenger limitation marking missing. 46 CFR 185.602
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 25 July 2025
Resolved 22 August 2025
Resolution: Accepted photo of signage.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 11 July 2025 Resolved
Battery terminals shall be of the soldered type and all connections shall be made to the battery terminals with permanent type connectors. Battery terminals found with wing nuts. 46 CFR 183.05-20
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 25 July 2025
Resolved 28 July 2025
Resolution: Accepted photo of correction.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 11 July 2025 Resolved
Each 'L' vessel will be equipped with one fire axe located in or adjacent to the pilothouse. Fire axe missing onboard. 46 CFR 181.35-1
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 25 July 2025
Resolved 28 July 2025
Resolution: Accepted photo of axe.
01 - Certificates & Documentation › 011 - Ships Certificates › Other (certificates)
Issued 1 June 2022 Resolved
A vessel that is exposed to salt water not more than three months in any 12 month period since the last examination must undergo a drydock examination and an internal structural examination at least once every five years. Vessel has failed to schedule a drydock examination prior to the drydock examination due date as listed on the COI. 46 CFR 176.600(c)(2)
Action required: 60 - Rectify deficiencies prior to movement
Resolved 26 April 2025
Resolution: MI attended vessel for drydock inspection 26APR2025.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 5 May 2022 Resolved
A length of fire hose shall be attached to each fire hydrant at all times. Vessels fire hose at #1 fire station was dry rotted, leaking, and needs replaced. 46 CFR 181.15-10(g) OLD T
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Resolved 5 May 2022
Resolution: Vessel procured a sufficient replacement firehose.
07 - Fire Safety › N/A - No Subsystem › Fire pumps and its pipes
Issued 5 May 2022 Resolved
All piping, valves, and fittings shall be in accordance with good marine practice and suitable for purpose intended. #2 Fire station on 2nd deck leaks at the fitting and needs repaired. 46 CFR 181.15-5(c) OLD T
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 4 June 2022
Resolved 11 July 2025
Resolution: Verified station is not leaking.
07 - Fire Safety › N/A - No Subsystem › Fire pumps and its pipes
Issued 5 May 2022 Resolved
The minimum capacity of the power fire pumps shall be 50GPM at a pressure of not less than 60psi at the pump outlet. Fire pump gauge was only reading 28PSI at the pump outlet. 46 CFR 181.10-1(c) OLD T
Condition: Invalid
Action required: 50 - Rectify deficiencies w/in 30 days
Due 4 June 2022
Resolved 11 July 2025
Resolution: Conducted tested and reissued 835.
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 5 May 2022 Resolved
Construction and arrangement of a vessel must allow the safe operation of the vessel giving consideration to provisions for a seaworthy hull. Multiple areas of the hull need repaired prior to credit drydock.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Resolved 26 April 2025
Resolution: MI attended vessel at drydock 26APR2025 verifying satisfactory repairs to hull.
07 - Fire Safety › N/A - No Subsystem › Means of escape
Issued 5 May 2022 Resolved
All vessels shall be provided with not less than two avenues of escape from all general areas accessible to the passengers. Emergency escape hatch was covered over the aft berthing which prevented it from opening. Crew cut the rug to allow hatch to open. 46 CFR 177.15-1 OLD T
Condition: Placed in Improper Service
Action required: 10 - Deficiency Rectified
Resolved 5 May 2022
Resolution: Crew cut rug so the escape hatch would open.
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 28 April 2021 Resolved
"Means provided to aid escape must be suitable for use in emergency conditions." 46 CFR 177.500 Port fwd escape hatch interior deteriorated. Fix by drydock (MAY 2022)
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 31 May 2022
Resolved 11 July 2025
Resolution: Verified condition of hatch.
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 28 April 2021 Resolved
"Receptable outlets for tools and similar apparatus must have a grounding connector." 46 CFR 183.370 Outets on upper deck aren't GFI- exposed to the weather Prone to dangerous electric shocks.
Condition: Design Flaw
Action required: 16 - Rectify deficiencies w/in 14 days
Due 12 May 2021
Resolved 11 May 2021
Resolution: Provided pictures of upgraded outlets to GFI receptacles.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Railing, gangway, walkway and means for safe passage
Issued 28 April 2021 Resolved
"Rails must be installed near the periphery of all decks of a vessel accessible to passengers or crew." 46 CFR 177.900 Forward stdb rail deteriorated and unsafe for any weight bearing pressure. Fix by MAY 2022 dry dock.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 31 May 2022
Resolved 26 April 2025
Resolution: MI attended vessel at drydock 26APR2025 verifying satisfactory repairs to rail.
07 - Fire Safety › N/A - No Subsystem › Fire detection and alarm system
Issued 28 April 2021 Resolved
"An independent modular smoke detecting unit must meet UL 217." 46 CFR 181.450 Modular smoke detector not properly working.
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Resolved 28 April 2021
Resolution: Resolved during inspection. Replaced batteries.
01 - Certificates & Documentation › 013 - Documents › Signs, indications
Issued 28 April 2021 Resolved
Display and distribution of informational material; display and distribution of a community service hot-line telephone number for crewmember assistance. 46 CFR 16.401, 46 CFR 185.212 Display DAPI information for crew member's awareness.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 12 May 2021
Resolved 29 April 2021
Resolution: Provided photos of DAPI requirements posted in the office.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 16 May 2019 Resolved
On a wood vessel of at least 26’ in length, a visual and audible alarm must be provided at the operating station to indicate a high water elvel in each space. Bilge high level alarm in the forward accommodation space is inoperable. Demonstrate proper operation prior to movement. 46CFR182.530 code 60
Condition: Damaged By Earlier Event
Action required: 60 - Rectify deficiencies prior to movement
Due 16 May 2019
Resolved 17 May 2019
Resolution: Witnessed proper operaiton of alarm. Failure was due to grounding, reviewed repairs.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 16 May 2019 Resolved
A vessel of more than 19.8m in length must carry a minimum of three life buoys of not less than 24” in diameter. Two of the vessel’s life buoy lines are degraded and need to be replaced. 46CFR180.70(a)(3) code 16
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 30 May 2019
Resolved 17 May 2019
Resolution: Operator provided proof of purchase for new liferings.
07 - Fire Safety › N/A - No Subsystem › Fixed fire extinguishing installation
Issued 6 August 2018 Resolved
For a fixed fire extinguishing system, all dead-end lines shall extend at least 2 inches beyond the last orifice and shall be closed with cap or plug. The CO2 line currently terminates at the nozzle. 46 CFR 181.20-20(d)
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 6 September 2018
Resolved 15 October 2018
Resolution: 2 inch piping extension was installed.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 6 August 2018 Resolved
At each inspection, the marine inspector shall require that all observed unsafe practices and hazardous situations be corrected. Party lights and ice chest on upper deck are currently "daisy chained" and being run off multiple extension cords. 46 CFR 176.25-50 46 CFR 176.25-50
Condition: Placed in Improper Service
Action required: 50 - Rectify deficiencies w/in 30 days
Due 6 September 2018
Resolved 15 October 2018
Resolution: Party lights taken out of service and extension cords were disconnected.
Operations/Management › Lifesaving › Op Readiness/Maintenance/Inspection
Issued 25 July 2017 Resolved
Vessel did not maintain lifesaving maintenance records. 46CFR185.700
Condition: Improper/Lack of Maintenance
Due 25 July 2017
Resolved 25 July 2017
Resolution: Discussed proper procedures with the CAPT.
Fire Fighting › Fixed CO2 Fire Extinguishing System › Servicing
Issued 25 July 2017 Resolved
Annual maintenance was overdue by one month, operator misunderstood regulations and believed he had +/- 3 months of the anniversary date to complete the maintenance. 46CFR176.810
Condition: Improper/Lack of Maintenance
Due 27 July 2017
Resolved 26 July 2017
Resolution: Received documentation for vsl rep proving completion of overdue installed firefighting system maintenance.
Operations/Management › Drug and Alcohol Testing › MIS Submission
Issued 25 July 2017 Resolved
Operating Company failed to submit MIS data for 2016.
Due 10 April 2018
Resolved 10 April 2018
Resolution: Forwarded to Investigations Shop for Enforcement
Pollution Prevention/Response › Prevention Equipment › Sewage System Tank
Issued 10 May 2017 Resolved
Underside of sewage tank is leaking at a rate of approximately 1 drip per 5 seconds.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 31 May 2017
Resolved 24 October 2018
Resolution: No leaks detected as of 08AUG2018.
Engineering › Diesel Engine (propulsion-reduction gear) › Waste Heat Recovery
Issued 30 July 2016 Resolved
Repair water pump on stabd engine to satisfactiuon of attending Marine Inspector. Vessel is restricted to <20 knot wind condition.
Condition: Design Flaw
Action required: 705 - Other - as specified
Due 6 August 2016
Resolved 3 August 2016
Fire Fighting › Fixed CO2 Fire Extinguishing System › Servicing
Issued 9 June 2016 Resolved
CO2 bottles Hydro dates expired.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 10 June 2016
Resolved 10 June 2016
Operations/Management › Bilge/Bilge System Management › Control of Oil Mixtures
Issued 9 June 2016 Resolved
Excessive oil in the bilges
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 10 June 2016
Resolved 10 June 2016
Resolution: Oil removed
Documentation › Logs/Records › Drug Test Records
Issued 22 July 2011 Resolved
Crewmembers not properly trained prior to assuming safety sensitive positions regarding company's drug and alcohol policy in accordance with 46 CFR 16.401.
Due 21 August 2011
Resolved 27 October 2011
Resolution: DER faxed DAPI copy of EAP training roster
Documentation › Logs/Records › Drug Test Records
Issued 22 July 2011 Resolved
Copy of latest MIS form not available for review as required by 46 CFR part 16.500.
Due 21 August 2011
Resolved 18 August 2011
Resolution: DER faxed DAPI copy of latest MIS form.
Lifesaving › Lifefloat › Painter
Issued 10 June 2008 Resolved
Life floats were not attached to vessel (weak links) IAW 180.137 (3).
Condition: Improper Installation
Due 10 June 2008
Resolved 10 June 2008
Resolution: Vessel owner corrected deficiency same day.
Lifesaving › Lifejacket/PFD (Type I) › Marking
Issued 10 June 2008 Resolved
One Type I PFD did not have vessels name stenciled on it IAW 199.70 b 3 (i).
Action required: 705 - Other - as specified
Due 10 June 2008
Resolved 10 June 2008
Electrical › Lighting (service) › Lighting Fixture
Issued 10 June 2008 Resolved
Two light fixtures in below deck overhead do not have covers over them, leaving light bulbs and wiring exposed.
Action required: 705 - Other - as specified
Due 10 June 2008
Resolved 10 June 2008
Engineering › Bilge Water Management System › Pump
Issued 10 June 2008 Resolved
Installed sewage discharge pump was not permanently mounted to vessels structure.
Action required: 705 - Other - as specified
Due 10 June 2008
Resolved 10 June 2008
Fire Fighting › Means of Escape › Escape Route Signs
Issued 3 May 2006 Resolved
Properly label fwd escape hatch IAW 46 CFR 185.606
Due 10 June 2006
Resolved 31 May 2006
Documentation › Manuals/Policy Documentation › Stability Instructions
Issued 3 May 2006 Resolved
Provide proper signage for passenger count allowed on upper deck IAW stability letter.
Due 10 June 2006
Resolved 31 May 2006
Deck/Cargo › Vapor Control Systems › Flame Screens
Issued 3 May 2006 Resolved
Install 30 X 30 mesh flame screens for both Port & Stbd fuel oil vents IAW 46 CFR 182.450 (e).
Due 10 June 2006
Resolved 8 June 2006
Personnel › Certificates/Documents/Licenses › Certificate, CPR Course Completion
Issued 3 May 2006 Resolved
Provide proof of completion for CPR/First Aid for crew members.
Due 10 June 2006
Resolved 8 June 2006
Electrical › Electrical Distribution System (service) › Outlet Box
Issued 3 May 2006 Resolved
Install cover plate for stbd fire station upper deck remote pump switch.
Due 10 June 2006
Resolved 10 May 2006
Lifesaving › Lifejacket/PFD (General) › Storage
Issued 3 May 2006 Resolved
Separate Adult & Child lifejackets IAW 46 CFR 180.25-10
Due 10 June 2006
Resolved 10 May 2006
Engineering › Shafting/Propeller Arrangements › Propeller Shaft
Issued 5 May 2005 Resolved
Properly adjust STBD shaft packing.
Action required: 705 - Other - as specified
Resolved 5 May 2005
Electrical › Electric Supply System (service) › Cable
Issued 5 May 2005 Resolved
Properly dead end electrical wires in way of lazarrate and FWD accommodation space.
Action required: 705 - Other - as specified
Resolved 5 May 2005
Documentation › Logs/Records › Logbook (official)
Issued 5 May 2005 Resolved
Provide life saving maintenance log and crew training log.
Action required: 705 - Other - as specified
Resolved 5 May 2005
Fire Fighting › Fixed Fire Detection System › Smoke Detectors
Issued 5 May 2005 Resolved
Prove proper operation of smoke detector in way of STBD aft berthing area.
Action required: 705 - Other - as specified
Resolved 5 May 2005
Lifesaving › Lifefloat › Float Free
Issued 5 May 2005 Resolved
Install spacers between life floats for proper float free arrangement.
Action required: 705 - Other - as specified
Resolved 5 May 2005
Fire Fighting › Remote Fuel Shutoff › General
Issued 5 May 2005 Resolved
Prove proper operation of STBD F/O remote cut out valve.
Action required: 705 - Other - as specified
Resolved 5 May 2005
Electrical › Electric Supply System (service) › Cable
Issued 19 April 2004 Resolved
Properly dead end un-used wires that have been disconnected from distribution panel located in electrical closet, main deck, aft port side of mian salon dining area.
Action required: 705 - Other - as specified
Resolved 19 April 2004
Lifesaving › Lifejacket/PFD (Type III) › Storage
Issued 7 April 2004 Resolved
Install life jacket stowage placards indicating quantity and size of jackets in their respective storage compartments.
Action required: 705 - Other - as specified
Resolved 20 April 2004
Construction/Loadline › Hull
Issued 25 August 2003 Resolved
Submit proposal to repair as new hull in way of fractured planks and broken frames.
Action required: 705 - Other - as specified
Due 31 October 2003
Resolved 25 August 2003
Operations/Management
Issued 25 August 2003 Resolved
Conduct U/W examination of vessel and complete full COI inspection after repairs have been completed to the satisfaction of the attending marine inspector.
Action required: 705 - Other - as specified
Due 31 October 2003
Resolved 20 April 2004
Construction/Loadline › Structures
Issued 23 May 2003 Resolved
Remove watertight door in collision bulkhead and restore watertight integrity of collision bulkhead prior to carrying over 32 passengers as allowed SEAMS letter dated 2 March 1983. LEGACY COMPONENT DESC: Transverse Bulkhead
Action required: 705 - Other - as specified
Due 1 August 2003
Resolved 13 December 2003
Resolution: Vessel granted exemption letter to keep atertight door, but must install audible/visual alarm at operating station to indicate door position. Door to remain closed at all times passengers on board.
Construction/Loadline › Structures
Issued 23 May 2003 Resolved
Renew wasted grounding bolt doubler block in way of galley bilge.
Action required: 701 - Prior to carriage of passengers/cargo
Due 1 August 2003
Resolved 9 July 2003
Electrical › Electric Supply System (service)
Issued 23 May 2003 Resolved
Submit plans for modification of vessel's AC and DC electrical system including installation of power inverter.
Action required: 701 - Prior to carriage of passengers/cargo
Due 1 August 2003
Resolved 9 July 2003
Resolution: Conducted a line by line review of the entire system. see requirements 48 through 53
Fire Fighting › Fixed CO2 Fire Extinguishing System
Issued 23 May 2003 Resolved
Perform operational test of fixed gas fire extinguishing system. LEGACY COMPONENT DESC: Operating Controls
Action required: 701 - Prior to carriage of passengers/cargo
Due 1 August 2003
Resolved 9 July 2003
Engineering › Diesel Engine (propulsion-reduction gear)
Issued 23 May 2003 Resolved
Submit plans for the installation of the new engine control system.
Action required: 701 - Prior to carriage of passengers/cargo
Due 1 August 2003
Resolved 9 July 2003
Construction/Loadline › Structures
Issued 23 May 2003 Resolved
Submit plans for the installation of the new stair tower to the upper deck (in way of old dry exhaust stack)
Action required: 701 - Prior to carriage of passengers/cargo
Due 1 August 2003
Resolved 9 July 2003
Lifesaving › Lifejacket/PFD (Type I)
Issued 23 May 2003 Resolved
Segregate adult and child PFD's.
Action required: 701 - Prior to carriage of passengers/cargo
Due 1 August 2003
Resolved 9 July 2003
Engineering › Diesel Engine (propulsion-reduction gear)
Issued 23 May 2003 Resolved
Submit plans for the installation of the new wet exhaust system for the main propulsion engines.
Action required: 701 - Prior to carriage of passengers/cargo
Due 1 August 2003
Resolved 30 July 2003
Lifesaving › Lifejacket/PFD (Type I)
Issued 23 May 2003 Resolved
Label location and quantity of all PFD's. LEGACY COMPONENT DESC: Marking
Action required: 701 - Prior to carriage of passengers/cargo
Due 1 August 2003
Resolved 9 July 2003
Pollution Prevention/Response › Prevention Equipment
Issued 23 May 2003 Resolved
Install bilge alarm in forward peak bilge. LEGACY COMPONENT DESC: Bilge Monitor
Action required: 701 - Prior to carriage of passengers/cargo
Due 1 August 2003
Resolved 9 July 2003
Resolution: Added to existing bilge alarm panel using 14 AWG marine grade wiring.
Construction/Loadline › Structures
Issued 23 May 2003 Resolved
Make all subdivision watertight bulkheads watertight. LEGACY COMPONENT DESC: Transverse Bulkhead
Action required: 705 - Other - as specified
Due 1 August 2003
Resolved 13 December 2003
Construction/Loadline › Structures
Issued 23 May 2003 Resolved
Make all deck hatches watertight.
Action required: 701 - Prior to carriage of passengers/cargo
Due 1 August 2003
Resolved 9 July 2003
Construction/Loadline › Hull
Issued 23 May 2003 Resolved
Install captive chain on aft watertight hatch.
Action required: 701 - Prior to carriage of passengers/cargo
Due 1 August 2003
Resolved 9 July 2003
Fire Fighting › Fire Hydrants
Issued 23 May 2003 Resolved
Label Fire station on upper deck. LEGACY COMPONENT DESC: Location/Position
Action required: 701 - Prior to carriage of passengers/cargo
Due 1 August 2003
Resolved 9 July 2003
Accommodation/Occupational Safety › Occupational Safety
Issued 23 May 2003 Resolved
Install rail coursings on all handrails as required by 46 CFR 177.900 LEGACY COMPONENT DESC: Deck Rail
Action required: 701 - Prior to carriage of passengers/cargo
Due 1 August 2003
Resolved 9 July 2003
Fire Fighting › Portable Dry Chemical Fire Extinguisher
Issued 23 May 2003 Resolved
Mount all fire extinguishers in approved brackets. LEGACY COMPONENT DESC: Mounting Bracket
Action required: 701 - Prior to carriage of passengers/cargo
Due 1 August 2003
Resolved 9 July 2003
Lifesaving › Buoyant Apparatus
Issued 23 May 2003 Resolved
Install weak link on vessel's lifefloats and mount lifefloats to ensure float free status.
Action required: 701 - Prior to carriage of passengers/cargo
Due 1 August 2003
Resolved 9 July 2003
Accommodation/Occupational Safety
Issued 23 May 2003 Resolved
Relocate emergency instructions.
Action required: 701 - Prior to carriage of passengers/cargo
Due 1 August 2003
Resolved 9 July 2003
Lifesaving
Issued 23 May 2003 Resolved
Post lifejacket placard.
Action required: 701 - Prior to carriage of passengers/cargo
Due 1 August 2003
Resolved 9 July 2003
Resolution: Issued a placard to owner.
Construction/Loadline › Structures
Issued 23 May 2003 Resolved
Make engine room door watertight and install approved dogging devices. LEGACY COMPONENT DESC: Transverse Bulkhead
Action required: 701 - Prior to carriage of passengers/cargo
Due 1 August 2003
Resolved 9 July 2003
Resolution: Accepted existing dogging device with new gasket.
Fire Fighting › Fixed Fire Detection System
Issued 23 May 2003 Resolved
Install smoke detectors approved for RV use in all ovenight accommodation spaces. Vessel is restricted from carrying passengers in lower accommodation spaces until satisfied. LEGACY COMPONENT DESC: Smoke Detectors
Action required: 705 - Other - as specified
Due 1 August 2003
Resolved 9 July 2003
Electrical › Lighting (emergency)
Issued 23 May 2003 Resolved
Submit plans to install emergency lighting in lower accommodation spaces in accordance with 46 CFR 183.432. vessel is restriced from carrying passengers in lower accommodation spaces until satisfied.
Action required: 705 - Other - as specified
Due 1 August 2003
Resolved 9 July 2003
Construction/Loadline › Penetrations
Issued 23 May 2003 Resolved
Renew thru hull fitting doubler-block in way of lazzarette port side aft deck drain. LEGACY COMPONENT DESC: Valve Flange
Action required: 705 - Other - as specified
Due 1 August 2003
Resolved 13 December 2003
Engineering › Sea-water System (primary cooling)
Issued 23 May 2003 Resolved
Renew "pedro" (non metallic hose connector) in engine room bilge for piping servicing toilet flushing pump. LEGACY COMPONENT DESC: Piping
Action required: 705 - Other - as specified
Due 1 August 2003
Resolved 20 April 2004
Accommodation/Occupational Safety › Occupational Safety
Issued 23 May 2003 Resolved
Submit plans for new upper deck railing. LEGACY COMPONENT DESC: Deck Rail
Action required: 705 - Other - as specified
Due 1 August 2003
Resolved 9 July 2003
Engineering › Bilge Water Management System
Issued 23 May 2003 Resolved
Restore vessel's bilge piping to forward peak compartment as required by 46 CFR 182.510. LEGACY COMPONENT DESC: Hose
Action required: 705 - Other - as specified
Due 1 August 2003
Resolved 13 December 2003
Engineering › Bilge Water Management System
Issued 23 May 2003 Resolved
Install positive shut off valves at hull penetrations for each electric submersible pump. LEGACY COMPONENT DESC: Valve
Action required: 705 - Other - as specified
Due 1 August 2003
Resolved 13 December 2003
Engineering › Bilge Water Management System
Issued 23 May 2003 Resolved
Submit plans for all vessel's new electric submersible bilge pumps including indicator lights at operating station that show when the pumps are running in "automatic mode" LEGACY COMPONENT DESC: Pump
Action required: 705 - Other - as specified
Due 1 August 2003
Resolved 20 April 2004
Construction/Loadline › Markings
Issued 23 May 2003 Resolved
Install draft markings on hull as required by 46 CFR 185.602. LEGACY COMPONENT DESC: Draft Marks/Indicating System
Action required: 705 - Other - as specified
Due 30 April 2005
Resolved 13 December 2003
Lifesaving › Lifebuoys
Issued 23 May 2003 Resolved
Correctly install retro-reflective tape on all lifering buoys.
Action required: 705 - Other - as specified
Due 1 August 2003
Resolved 9 July 2003
Navigation › Collision/Grounding Avoidance
Issued 23 May 2003 Resolved
Show proof the vessel's navigation lights comply with 46 CFR 183.420 (UL 1104 standard) or renew with approved lights. LEGACY COMPONENT DESC: Navigation Lights
Action required: 705 - Other - as specified
Due 1 August 2003
Resolved 20 April 2004
Accommodation/Occupational Safety › Medical/First Aid
Issued 23 May 2003 Resolved
Provide USCG approved first aid kit as required by 46 CFR 1884.710
Action required: 705 - Other - as specified
Due 1 August 2003
Resolved 20 April 2004
Accommodation/Occupational Safety › Cooking Systems
Issued 23 May 2003 Resolved
Post label on stove "Override switch must be secured when wood counters are installed on stove burners" or remove wood counters from vessel.
Action required: 705 - Other - as specified
Due 1 August 2003
Resolved 9 July 2003
Engineering › Fuel Oil Service System
Issued 23 May 2003 Resolved
Renew fuel oil lines in engine room as indicated by attending inspector. New hoses must meet of exceed SAE J1942. LEGACY COMPONENT DESC: Hose
Action required: 705 - Other - as specified
Due 1 August 2003
Resolved 13 December 2003
Pollution Prevention/Response › Prevention Equipment
Issued 23 May 2003 Resolved
Renew bilge suction "pedro" located under stair tower to lower accommodation space. LEGACY COMPONENT DESC: Oily Mixture Discharge Fixed Piping System
Action required: 705 - Other - as specified
Due 1 August 2003
Resolved 13 December 2003
Accommodation/Occupational Safety › Occupational Safety
Issued 23 May 2003 Resolved
Remove obstruction (carpet) from deck above aft accommodation space emergency egress.
Action required: 705 - Other - as specified
Due 1 August 2003
Resolved 20 April 2004
Engineering › Pressure Vessel
Issued 23 May 2003 Resolved
Renew pressure/temperature valve from oil fired hot water heater.
Action required: 705 - Other - as specified
Due 1 August 2003
Resolved 13 December 2003
Engineering › Fuel Oil Storage/Transfer System
Issued 23 May 2003 Resolved
Show proof fuel oil tanks are vented as required by 46 CFR 182.450 LEGACY COMPONENT DESC: Vent Pipe
Action required: 705 - Other - as specified
Due 1 August 2003
Resolved 20 April 2004
Operations/Management › Drills/Instruction
Issued 23 May 2003 Resolved
Conduct U/W drills in presence of marine inspector.
Action required: 701 - Prior to carriage of passengers/cargo
Due 1 August 2003
Resolved 9 July 2003
Accommodation/Occupational Safety › Occupational Safety
Issued 23 May 2003 Resolved
Label emergency egress in engine room and ensure egress hatch is watertight.
Action required: 705 - Other - as specified
Due 1 August 2003
Resolved 9 July 2003
Documentation › Certificates/Documents
Issued 23 May 2003 Resolved
Post required documents.
Action required: 705 - Other - as specified
Due 1 August 2003
Resolved 13 December 2003
Construction/Loadline › Structures
Issued 23 May 2003 Resolved
Submit proposal to repair isolated wood rot in way of stem and lazzarette. Vessel is placed on a 2 year drydock interval until extend of rot has been determined
Action required: 705 - Other - as specified
Due 30 April 2005
Resolved 20 April 2004
Resolution: Vessel given drydock credit and placed into drydock dates in accordance with 46 CFR 176.600.
Construction/Loadline › Structures
Issued 23 May 2003 Resolved
Submit proposal (plans) to install indicator lights at operating station in watertight doors to show the doors are in the closed position. LEGACY COMPONENT DESC: Door
Action required: 705 - Other - as specified
Due 1 August 2003
Resolved 20 April 2004
Construction/Loadline › Structures
Issued 23 May 2003 Resolved
Post sign on watertight doors stating "doors must be secured closed when vessel is underway. LEGACY COMPONENT DESC: Door
Action required: 705 - Other - as specified
Due 1 August 2003
Resolved 9 July 2003
Fire Fighting › Fixed CO2 Fire Extinguishing System
Issued 23 May 2003 Resolved
Provide means to have all fixed power ventilation servicing engine room automatically shut down upon activation of fixed gas fire extinguishing system. LEGACY COMPONENT DESC: Operating Controls
Action required: 705 - Other - as specified
Due 1 August 2003
Resolved 9 July 2003
Engineering
Issued 23 May 2003 Resolved
Provide information on manufacture of vessels mufflers. Specifically, provide proof the mufflers are made from fireproof/ retardant resins.
Action required: 705 - Other - as specified
Due 9 August 2003
Resolved 27 August 2003
Resolution: See attached fax
Construction/Loadline › Structures
Issued 23 May 2003 Resolved
Make all pvc & plastic piping penetrations of required watertight bulkheads comply with the requirements of 46 CFR 182.40-1(a). Submit proposal for this requirement prior to accomplishing requirement. LEGACY COMPONENT DESC: Transverse Bulkhead
Action required: 705 - Other - as specified
Due 30 April 2005
Resolved 20 April 2004
Electrical › Lighting (emergency)
Issued 23 May 2003 Resolved
Install junction box for wiring splice for new "E" lightiing in lower accommodation space. LEGACY COMPONENT DESC: Conductor
Action required: 705 - Other - as specified
Due 9 August 2003
Resolved 13 December 2003
Electrical › Electrical Distribution System (service)
Issued 23 May 2003 Resolved
Provide circuit protection for the following conductors: Inverter output, both legs of amp guage from shunt, power conductor for 12 VDC junction block, power conductor for 24 VDC junction block for both 24 VDC battery banks, and battery charger conductors at 12 VDC batteries LEGACY COMPONENT DESC: Circuit Breaker
Action required: 705 - Other - as specified
Due 9 August 2003
Resolved 27 April 2004
Electrical › Electrical Distribution System (service)
Issued 23 May 2003 Resolved
Provide circuit protection for the following conductors: conductor for DC power to new engine controls, & conductor for 12 VDC power panel to bridge. LEGACY COMPONENT DESC: Circuit Breaker
Action required: 705 - Other - as specified
Due 9 August 2003
Resolved 20 April 2004
Electrical › Electrical Distribution System (service)
Issued 23 May 2003 Resolved
Renew conductor to lazarette bridge using 10 AWG marine cable. LEGACY COMPONENT DESC: Cable
Action required: 705 - Other - as specified
Due 9 August 2003
Resolved 13 December 2003
Electrical › Electrical Distribution System (service)
Issued 23 May 2003 Resolved
Renew conductor to mathers controls on bridge sizing conductor as required by 46 CFR.183. LEGACY COMPONENT DESC: Cable
Action required: 705 - Other - as specified
Due 9 August 2003
Resolved 20 April 2004
Operations/Management
Issued 23 May 2003 Resolved
Install PA system as required by 46 CFR 184. This requirement must be accommplished prior to carrying passengers for hire. As a substitute the vessel's master may provide a portable electric powered bullhorn to satisfy the PA system requirement until a permanent PA can be installed on the vessel.
Action required: 705 - Other - as specified
Due 9 August 2003
Resolved 20 April 2004
Operations/Management › Passenger Operations
Issued 5 August 2002 Resolved
Complete new to zone inspection with [name withheld] prior to carrying passengers.
Condition: Unknown
Action required: 705 - Other - as specified
Resolved 20 April 2004
Communications › Audible Communications
Issued 14 November 2001 Resolved
MISSING PA SYSTEM. CORRECTED
Due 14 January 2002
Resolved 7 May 2002
Documentation › Certificates/Documents › Certificate of Documentation (CG-1270)
Issued 14 November 2001 Resolved
COD EXPIRED 12/00. RECEIVED RENEWED COD DATED 28 AUG 01, EXP 30 AUG 02.
Action required: 701 - Prior to carriage of passengers/cargo
Due 14 November 2001
Resolved 14 December 2001
Resolution: RENEWED COD.
Lifesaving › Buoyant Apparatus
Issued 14 November 2001 Resolved
DID NOT HAVE 100% LIFESAVING. NEED TO ACQUIRE LIFE FLOATS TO ACCOMODATE 24 ADDITIONAL PERSONS FOR A TOTAL OF 34.
Action required: 701 - Prior to carriage of passengers/cargo
Due 14 December 2001
Resolved 3 June 2002
Construction/Loadline
Issued 30 August 1999 Resolved
PROVE SAT OPERATION OF ALL HIGH LEVEL BILGE ALARMS.
Condition: Unknown
Due 10 September 1999
Resolved 22 September 1999
Electrical
Issued 30 September 1998 Resolved
REMOVE DEADENDED WIRING FROM PORT MAIN.
Condition: Unknown
Due 30 November 1998
Resolved 3 December 1998
Lifesaving
Issued 30 September 1998 Resolved
2 PFD'S NEED RETRO RENEWED.
Condition: Unknown
Due 30 November 1998
Resolved 3 December 1998
Navigation
Issued 30 September 1998 Resolved
PROVIDE CURRENT PUBS (COAST PILOT, LIGHT LIST, NAVRULS).
Condition: Unknown
Due 30 November 1998
Resolved 3 December 1998
Engineering
Issued 30 September 1998 Resolved
REPAIR OR REPLACE TACHOMETERS IN E/R.
Condition: Unknown
Due 30 November 1998
Resolved 3 December 1998
Lifesaving
Issued 30 September 1998 Resolved
REMOVE OIL FROM DRIP PANS BENEATH MAINS.
Condition: Unknown
Due 30 November 1998
Resolved 3 December 1998
Unknown
Issued 9 August 1995 Resolved
VESSEL NOT PARTICIPATING IN RANDOM DRUG TESTING PROGRAM.
Condition: Unknown
Due 9 August 1995
Resolved 9 August 1995
Fire Fighting
Issued 9 August 1995 Resolved
ALL FIXED AND PORTABLE FIRE EXTINGUISHERS OVERDUE FOR SERVICING. PORTABLE B-II EXTINGUISHERS DUE FOR HYDRO TESTING. TO BE COMPLETED PRIOR TO THE CARRIAGE OF PASSENGERS.
Condition: Unknown
Due 9 August 1995
Resolved 9 August 1995
Documentation
Issued 24 May 1994 Resolved
PROVIDE WRITTEN WASTE MANAGEMENT PLAN.
Condition: Unknown
Due 29 July 1994
Resolved 29 July 1994
Construction/Loadline
Issued 24 May 1994 Resolved
PROVE OPERATION OF VESSEL UNDERWAY PRIOR TO THE CARRIAGE OF PASSENGERS.
Condition: Unknown
Due 29 July 1994
Resolved 29 July 1994
Engineering
Issued 24 May 1994 Resolved
CLEAN MDE DRIP PANS
Condition: Unknown
Due 29 July 1994
Resolved 29 July 1994
Lifesaving
Issued 24 May 1994 Resolved
PROPERLY STOW AND LABEL ALL LIFE JACKETS AND STOWAGE AREAS PRIOR TO THE CARRIAGE OF PASSENGERS.
Condition: Unknown
Due 29 July 1994
Resolved 29 July 1994
Construction/Loadline
Issued 24 May 1994 Resolved
EFFECT PERMANENT REPAIRS TO PLANKING ON PORT BOW AND PORT BULWARK
Condition: Unknown
Due 29 July 1994
Resolved 29 July 1994
Accommodation/Occupational Safety
Issued 24 May 1994 Resolved
ENSURE PROPER OPERATION AND STENCILING OF EMERGENCY ESCAPE HATCH PRIOR TO THE CARRIAGE OF PASSENGERS.
Condition: Unknown
Due 29 July 1994
Resolved 29 July 1994
Documentation
Issued 24 May 1994 Resolved
PROVIDE WRITTEN DRUG TESTING PROGRAM IN ACCORDANCE WITH 46 CFR 16.
Condition: Unknown
Due 29 July 1994
Resolved 29 July 1994
Lifesaving
Issued 17 June 1993 Resolved
PROVIDE THREE ADDITIONAL HAND HELD RED FLARES AND 3 ADDITIONAL HAND HELD ORGANGE SMOKES, OR 6 COMBINATION FLARE/SMOKES NO LATER THAN 24JUN93.
Condition: Unknown
Due 24 June 1993
Resolved 24 June 1993
Documentation
Issued 17 June 1993 Resolved
HAVE FCC INSPECTION CONDUCTED PRIOR TO 17JUL93.
Condition: Unknown
Due 13 July 1993
Resolved 13 July 1993
Engineering
Issued 25 June 1992 Resolved
REPAIR BROKEN RECOR FUEL FILTER HOUSING.
Condition: Unknown
Due 15 July 1992
Resolved 10 July 1992
Engineering
Issued 25 June 1992 Resolved
DEMONSTRATE PROPER OPERATION OF BOTH MAIN PROPULSION ENGINES.
Condition: Unknown
Due 15 July 1992
Resolved 10 July 1992
Electrical
Issued 25 June 1992 Resolved
CHARGE/ REPLACE DEAD GENSET STARTING BATTERY.
Condition: Unknown
Due 15 July 1992
Resolved 10 July 1992
Electrical
Issued 25 June 1992 Resolved
REPAIR LOOSE FIXTURES AND WIRING ON MAIN DECK PORT AND STARBOARD.
Condition: Unknown
Due 15 July 1992
Resolved 10 July 1992
Fire Fighting
Issued 25 June 1992 Resolved
SHOW PROOF OF HYDROSTATIC TEST DATE ON FIXED CO2 SYSTEM.
Condition: Unknown
Due 15 July 1992
Resolved 10 July 1992
Navigation
Issued 25 June 1992 Resolved
REPAIR SHIPS HORN.
Condition: Unknown
Due 15 July 1992
Resolved 10 July 1992
Lifesaving
Issued 25 June 1992 Resolved
LIMITED TO 26 PASSENGERS UNTIL SUCH TIME AS SATISFACTORY NUMBER OF PFD'S ARE PROVIDED.
Condition: Unknown
Due 15 July 1992
Resolved 10 July 1992
Unknown
Issued 5 April 1988 Resolved
PROVIDE RELIEF VALVE FOR A/R IN ENGINEROOM.
Condition: Unknown
Due 5 April 1988
Resolved 5 April 1988
Documentation
Issued 17 March 1987 Resolved
POST EMERGENCY CHECKLIST.
Condition: Unknown
Due 17 March 1987
Resolved 17 March 1987
Engineering
Issued 17 March 1987 Resolved
REPAIR AS NEW BONDING STRAPS FROM COUPLING TO PROP SHAFTS, PORT AND STARBOARD, UNDER DECK AREA OF FORWARD PASSENGER'S CABINS.
Condition: Unknown
Due 17 March 1987
Resolved 17 March 1987
Engineering
Issued 17 March 1987 Resolved
INSTALL STOP NUTS ON STARBOARD SHAFT COUPLING, 6:00 POSITION, IN AREA BELOWFORWARD PASSENGER CABIN DECKING.
Condition: Unknown
Due 17 March 1987
Resolved 17 March 1987
Documentation
Issued 17 March 1987 Resolved
CORRECT VESSEL DOCUMENT TO REFLECT CURRENT ADDRESS OF OWNERS; TO READ: 10900 N.E. 4TH ST. BELLEVUE, WA 98004
Condition: Unknown
Due 17 March 1987
Resolved 17 March 1987

Casualty record · 2

17 July 2003Routine · role: Involved in a Marine Casualty · serious marine incident, as classified · activity 1853112
1 September 2017Routine · role: Involved in a Marine Casualty · serious marine incident, as classified · 1 injured · activity 6282029
Each line is an incident investigation the Coast Guard recorded with this hull among the vessels involved, with the date and the classification the Coast Guard gave it, and the bridge, lock or dam the investigation names where it names one. Involvement is not fault. The investigation narrative is not published. Source: IIR, through 2026.

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.