← All vessels
SAFARI ROSE
Passenger (Inspected) · Passenger Ship class · Built 1950s · USCG Southwest District (CGD-SW) · Other hulls named SAFARI ROSE
SAFARI ROSE is a 1959 passenger vessel (inspected). The Coast Guard has recorded 74 inspections since 1985, most recently in July 2025, along with 140 deficiencies, 1 operational control and 2 casualty investigations between 2003 and 2017.
Records from 1985 to 2025. Most recent: inspection, 11 July 2025.
- Built
- 1959
- Last inspected
- 11 July 2025
- Documentation
- Valid · documentation file of 10 September 2026
- Deficiencies
- 140 recorded · 0 without a recorded resolution
- Controls
- None recorded without a removal date
- Casualties
- 2 investigations · 2003–2017
Identity
278393
WDE5075
54844
Flag
UNITED STATES
367361710 (licence lapsed)
Maury page id
psix-54844
Inspections, by type
…with no type recorded8
Years with a record
36 calendar years (1985–2025)
The 74 inspections in the strip above, split by the kind of activity the US
Coast Guard recorded. Years with a record are calendar years in which a record exists, not
years in service. What Maury does not do.
Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 1977.
Documentation record
Registered dimensions (L × B × D)71.5 ft × 18.5 ft × 8.9 ft
Registered tonnagegross 90 / net 61
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderALLIED MARINE CORPORATION · MIAMI, FL, UNITED STATES · built 1959
Hull materialWood
PropulsionDiesel Reduction
Hull shapeNot recorded
Hull configurationNot recorded
Hailing portzephyr cove, NV
Trade endorsementsCoastwise, unrestricted, Fishery, Recreational
DocumentationValid · issued 14 January 2026 · expires 31 January 2027
Service, as the file records itPassenger (Inspected)
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it90 - Regulatory (Subpart C or D), Gross Ton
61 - Regulatory (Subpart C or D), Net Ton
61 - Regulatory (Subpart C or D), Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 September 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
Radio station licence
WDE5075MMSI 367361710 · expired · compulsorily equipped · granted 7 June 2008, cancelled 11 August 2018
WCX8708MMSI not assigned · expired · voluntarily equipped · granted 4 December 1997, cancelled 9 February 2008 · licensed under a name not among this hull’s recorded names (not shown)
FCC Universal Licensing System ship-station file of 6 September 2026, matched to this hull on its
US Official Number. Status and dates are the file’s own. The licensee is not read from the file and is not shown.
A lapsed licence’s MMSI is still the number the vessel transmitted under while it was valid.
Inspection history · 74
11 July 2025
COI Inspection · Deficiency Check
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 8168911
5 May 2022
Annual Inspection · Administrative Inspection
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 7449438
28 April 2021
Annual Inspection · Deficiency Check
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 7173963
6 August 2020
Internal Structural Exam · Annual Inspection
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 7021892
16 May 2019
COI Inspection · Administrative Inspection · Deficiency Check
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 6681438
5 August 2018
Internal Structural Exam · Annual Inspection · Administrative Inspection
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 6501229
1 September 2017
Type not recorded
No type recorded · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 6282029
25 July 2017
Annual Inspection · DAPI Audit
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 6216750
6 June 2017
Drydock Exam · Administrative Inspection · Internal Structural Exam
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 6166259
10 May 2017
Internal Structural Exam · Drydock Extension
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 6146556
30 July 2016
Administrative Inspection
Administrative · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 5962794
22 July 2016
Internal Structural Exam · Drydock Extension
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 5949750
9 June 2016
Annual Inspection
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 5907343
7 May 2012
Administrative Inspection · Annual Inspection
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 4304974
22 July 2011
Deficiency Check · DAPI Audit
Physical examination · USCG Southwest District (dp) · USCG Southwest District (CGD-SW) · Activity 4098493
5 March 2010
Administrative Inspection
Administrative · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 3690707
4 May 2009
Drydock Exam
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 3465450
13 April 2009
COI Inspection · Drydock Extension
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 3450281
2 February 2009
Drydock Extension
Administrative · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 3415980
10 June 2008
Annual Inspection
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 3228017
20 March 2007
Annual Inspection
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 2889100
3 May 2006
Annual Inspection · Deficiency Check
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 2639873
5 May 2005
Annual Inspection
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 2353428
7 April 2004
Deficiency Check · COI Inspection
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 2039300
2 March 2004
Plan Review "T" Boat
Administrative · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 2016542
13 December 2003
Deficiency Check
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1964306
14 November 2003
Administrative Inspection
Administrative · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1947770
27 October 2003
Plan Review "T" Boat
Administrative · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1937298
22 July 2003
Deficiency Check · Examination of Repairs · Plan Review "T" Boat · Damage Survey
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1887008
17 July 2003
Type not recorded
No type recorded · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1853112
17 July 2003
Type not recorded
No type recorded · Station Lake Tahoe · USCG Southwest District (CGD-SW) · Activity 1906305
25 June 2003
Deficiency Check · Administrative Inspection · Inclining Experiment
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1785393
15 April 2003
Hull Examination
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1772259
5 August 2002
COI Inspection
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1657000
14 November 2001
Re-Inspection
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1625805
15 August 2000
Re-Inspection
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1436440
13 April 2000
Hull Examination
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1369608
22 September 1999
Deficiency Check
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1340395
30 August 1999
COI Inspection
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1361083
30 September 1998
Re-Inspection
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1421561
1 October 1997
Re-Inspection
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1462596
17 September 1996
Administrative
Administrative · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1270556
1 August 1996
COI Inspection
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1402280
20 June 1996
Deficiency Check
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1242092
28 March 1996
Deficiency Check
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1402213
9 August 1995
Hull Examination
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 774154
9 August 1995
COI Inspection · Hull Examination
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1400221
17 October 1994
Damage Survey
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1440872
24 September 1994
Type not recorded
No type recorded · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 70397
15 August 1994
Administrative
Administrative · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1177127
29 July 1994
Deficiency Check
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1171939
24 May 1994
COI Inspection
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1409136
12 July 1993
Deficiency Check
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1155533
24 June 1993
Deficiency Check
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1154031
17 June 1993
COI Inspection
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1134720
17 May 1993
Type not recorded
No type recorded · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1373856
24 August 1992
Administrative
Administrative · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 949525
10 July 1992
Deficiency Check
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 946484
25 June 1992
COI Inspection
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1266630
17 March 1992
Hull Examination
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 960110
20 December 1991
Drydock Extension
Administrative · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 961117
26 September 1991
Administrative
Administrative · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1245597
9 August 1991
Type not recorded
No type recorded · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1250386
28 June 1991
COI Inspection
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1247680
13 June 1991
Administrative
Administrative · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1327106
25 October 1990
Type not recorded
No type recorded · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 912775
29 June 1990
Hull Examination · COI Inspection
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 928604
5 March 1990
Administrative
Administrative · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 921011
6 March 1989
COI Inspection
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 890687
5 April 1988
COI Inspection
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1301288
17 March 1987
COI Inspection
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1016078
17 March 1987
Hull Examination
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1016080
10 March 1986
COI Inspection
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1299143
15 March 1985
Type not recorded
No type recorded · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1288331
Deficiency record · 140
07 - Fire Safety › N/A - No Subsystem › Fire pumps and its pipes
Issued 11 July 2025
Resolved
On a vessel of more than 65 feet in length, the minimum capacity of the fire pump must be 50 gpm at a pressure of not less than 60 psi. Fire pump gauge read max of 25 psi during testing.
46 CFR 181.300
07 - Fire Safety › N/A - No Subsystem › Fixed fire extinguishing installation
Issued 11 July 2025
Resolved
A distribution line must extend at least 2" beyond the last orifice and be closed with a cap or plug. Distribution line nearest bottles terminates with discharge horn and is missing 2" piping addition.
46 CFR 181.410
07 - Fire Safety › N/A - No Subsystem › Fire pumps and its pipes
Issued 11 July 2025
Resolved
At each inspection for certification, the owner must be prepared to conduct tests and have the vessel ready for inspection of its fire protection equipment, including the following: operation of the fire main system. Fire main valve in the engine room leaks approximately 1 drop per second when running.
46 CFR 176.810
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 11 July 2025
Resolved
At each inspection for certification of a vessel, the owner shall be prepared to conduct tests and have the vessel ready for inspections of machinery, including the following: Operational test of the means provided for pumping bilges. Bilge pump float switch beneath galley is mounted on a board that allows it to float with rising water. Secure float to the bilge area.
46 CFR 176.804
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Operation of machinery
Issued 11 July 2025
Resolved
At each inspection for certification of a vessel, the owner shall be prepared to conduct tests and have the vessel ready for inspections of machinery, including the following: operation of the main propulsion machinery. Starboard shaft has a continious leak when main engines are off and vessel is idle.
46 CFR 176.804
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 11 July 2025
Resolved
All wiring and cables shall be suitable for marine service and the particular installation used. Live, dead end wires found in lazarette on forward bulkhead beneath hydraulic oil tank and on upper weatherdeck inside old control station.
46 CFR 183.10-20
08 - Alarms › N/A - No Subsystem › Other (alarms)
Issued 11 July 2025
Resolved
At each inspection for certification of a vessel, the owner shall be prepared to conduct tests and have the vessel ready for inspections of machinery, including the following: test of machinery alarms including bilge high level alarms. Lazarette and forepeak high level alarm float switches stick in the raised position and do not operate as designed.
46 CFR 176.804
09 - Working and Living Conditions › 092 - Working Conditions › Safe means of access
Issued 11 July 2025
Resolved
On a vessel on which the number of passengers permitted on upper decks is limited by stability criteria, the max number of passengers allowed on an upper deck must be indicated by a durable marking of at least 1" numbers and letters at the entranceway to that deck. Second deck passenger limitation marking missing.
46 CFR 185.602
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 11 July 2025
Resolved
Battery terminals shall be of the soldered type and all connections shall be made to the battery terminals with permanent type connectors. Battery terminals found with wing nuts.
46 CFR 183.05-20
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 11 July 2025
Resolved
Each 'L' vessel will be equipped with one fire axe located in or adjacent to the pilothouse. Fire axe missing onboard.
46 CFR 181.35-1
01 - Certificates & Documentation › 011 - Ships Certificates › Other (certificates)
Issued 1 June 2022
Resolved
A vessel that is exposed to salt water not more than three months in any 12 month period since the last examination must undergo a drydock examination and an internal structural examination at least once every five years. Vessel has failed to schedule a drydock examination prior to the drydock examination due date as listed on the COI.
46 CFR 176.600(c)(2)
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 5 May 2022
Resolved
A length of fire hose shall be attached to each fire hydrant at all times. Vessels fire hose at #1 fire station was dry rotted, leaking, and needs replaced. 46 CFR 181.15-10(g) OLD T
07 - Fire Safety › N/A - No Subsystem › Fire pumps and its pipes
Issued 5 May 2022
Resolved
All piping, valves, and fittings shall be in accordance with good marine practice and suitable for purpose intended. #2 Fire station on 2nd deck leaks at the fitting and needs repaired. 46 CFR 181.15-5(c) OLD T
07 - Fire Safety › N/A - No Subsystem › Fire pumps and its pipes
Issued 5 May 2022
Resolved
The minimum capacity of the power fire pumps shall be 50GPM at a pressure of not less than 60psi at the pump outlet. Fire pump gauge was only reading 28PSI at the pump outlet. 46 CFR 181.10-1(c) OLD T
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 5 May 2022
Resolved
Construction and arrangement of a vessel must allow the safe operation of the vessel giving consideration to provisions for a seaworthy hull. Multiple areas of the hull need repaired prior to credit drydock.
07 - Fire Safety › N/A - No Subsystem › Means of escape
Issued 5 May 2022
Resolved
All vessels shall be provided with not less than two avenues of escape from all general areas accessible to the passengers. Emergency escape hatch was covered over the aft berthing which prevented it from opening. Crew cut the rug to allow hatch to open. 46 CFR 177.15-1 OLD T
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 28 April 2021
Resolved
"Means provided to aid escape must be suitable for use in emergency conditions." 46 CFR 177.500
Port fwd escape hatch interior deteriorated. Fix by drydock (MAY 2022)
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 28 April 2021
Resolved
"Receptable outlets for tools and similar apparatus must have a grounding connector." 46 CFR 183.370
Outets on upper deck aren't GFI- exposed to the weather Prone to dangerous electric shocks.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Railing, gangway, walkway and means for safe passage
Issued 28 April 2021
Resolved
"Rails must be installed near the periphery of all decks of a vessel accessible to passengers or crew." 46 CFR 177.900
Forward stdb rail deteriorated and unsafe for any weight bearing pressure. Fix by MAY 2022 dry dock.
07 - Fire Safety › N/A - No Subsystem › Fire detection and alarm system
Issued 28 April 2021
Resolved
"An independent modular smoke detecting unit must meet UL 217." 46 CFR 181.450
Modular smoke detector not properly working.
01 - Certificates & Documentation › 013 - Documents › Signs, indications
Issued 28 April 2021
Resolved
Display and distribution of informational material; display and distribution of a community service hot-line telephone number for crewmember assistance. 46 CFR 16.401, 46 CFR 185.212
Display DAPI information for crew member's awareness.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 16 May 2019
Resolved
On a wood vessel of at least 26’ in length, a visual and audible alarm must be provided at the operating station to indicate a high water elvel in each space. Bilge high level alarm in the forward accommodation space is inoperable. Demonstrate proper operation prior to movement. 46CFR182.530 code 60
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 16 May 2019
Resolved
A vessel of more than 19.8m in length must carry a minimum of three life buoys of not less than 24” in diameter. Two of the vessel’s life buoy lines are degraded and need to be replaced. 46CFR180.70(a)(3) code 16
07 - Fire Safety › N/A - No Subsystem › Fixed fire extinguishing installation
Issued 6 August 2018
Resolved
For a fixed fire extinguishing system, all dead-end lines shall extend at least 2 inches beyond the last orifice and shall be closed with cap or plug. The CO2 line currently terminates at the nozzle.
46 CFR 181.20-20(d)
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 6 August 2018
Resolved
At each inspection, the marine inspector shall require that all observed unsafe practices and hazardous situations be corrected. Party lights and ice chest on upper deck are currently "daisy chained" and being run off multiple extension cords.
46 CFR 176.25-50
46 CFR 176.25-50
Operations/Management › Lifesaving › Op Readiness/Maintenance/Inspection
Issued 25 July 2017
Resolved
Vessel did not maintain lifesaving maintenance records. 46CFR185.700
Fire Fighting › Fixed CO2 Fire Extinguishing System › Servicing
Issued 25 July 2017
Resolved
Annual maintenance was overdue by one month, operator misunderstood regulations and believed he had +/- 3 months of the anniversary date to complete the maintenance. 46CFR176.810
Operations/Management › Drug and Alcohol Testing › MIS Submission
Issued 25 July 2017
Resolved
Operating Company failed to submit MIS data for 2016.
Pollution Prevention/Response › Prevention Equipment › Sewage System Tank
Issued 10 May 2017
Resolved
Underside of sewage tank is leaking at a rate of approximately 1 drip per 5 seconds.
Engineering › Diesel Engine (propulsion-reduction gear) › Waste Heat Recovery
Issued 30 July 2016
Resolved
Repair water pump on stabd engine to satisfactiuon of attending Marine Inspector. Vessel is restricted to <20 knot wind condition.
Fire Fighting › Fixed CO2 Fire Extinguishing System › Servicing
Issued 9 June 2016
Resolved
CO2 bottles Hydro dates expired.
Operations/Management › Bilge/Bilge System Management › Control of Oil Mixtures
Issued 9 June 2016
Resolved
Excessive oil in the bilges
Documentation › Logs/Records › Drug Test Records
Issued 22 July 2011
Resolved
Crewmembers not properly trained prior to assuming safety sensitive positions regarding company's drug and alcohol policy in accordance with 46 CFR 16.401.
Documentation › Logs/Records › Drug Test Records
Issued 22 July 2011
Resolved
Copy of latest MIS form not available for review as required by 46 CFR part 16.500.
Lifesaving › Lifefloat › Painter
Issued 10 June 2008
Resolved
Life floats were not attached to vessel (weak links) IAW 180.137 (3).
Lifesaving › Lifejacket/PFD (Type I) › Marking
Issued 10 June 2008
Resolved
One Type I PFD did not have vessels name stenciled on it IAW 199.70 b 3 (i).
Electrical › Lighting (service) › Lighting Fixture
Issued 10 June 2008
Resolved
Two light fixtures in below deck overhead do not have covers over them, leaving light bulbs and wiring exposed.
Engineering › Bilge Water Management System › Pump
Issued 10 June 2008
Resolved
Installed sewage discharge pump was not permanently mounted to vessels structure.
Fire Fighting › Means of Escape › Escape Route Signs
Issued 3 May 2006
Resolved
Properly label fwd escape hatch IAW 46 CFR 185.606
Documentation › Manuals/Policy Documentation › Stability Instructions
Issued 3 May 2006
Resolved
Provide proper signage for passenger count allowed on upper deck IAW stability letter.
Deck/Cargo › Vapor Control Systems › Flame Screens
Issued 3 May 2006
Resolved
Install 30 X 30 mesh flame screens for both Port & Stbd fuel oil vents IAW 46 CFR 182.450 (e).
Personnel › Certificates/Documents/Licenses › Certificate, CPR Course Completion
Issued 3 May 2006
Resolved
Provide proof of completion for CPR/First Aid for crew members.
Electrical › Electrical Distribution System (service) › Outlet Box
Issued 3 May 2006
Resolved
Install cover plate for stbd fire station upper deck remote pump switch.
Lifesaving › Lifejacket/PFD (General) › Storage
Issued 3 May 2006
Resolved
Separate Adult & Child lifejackets IAW 46 CFR 180.25-10
Engineering › Shafting/Propeller Arrangements › Propeller Shaft
Issued 5 May 2005
Resolved
Properly adjust STBD shaft packing.
Electrical › Electric Supply System (service) › Cable
Issued 5 May 2005
Resolved
Properly dead end electrical wires in way of lazarrate and FWD accommodation space.
Documentation › Logs/Records › Logbook (official)
Issued 5 May 2005
Resolved
Provide life saving maintenance log and crew training log.
Fire Fighting › Fixed Fire Detection System › Smoke Detectors
Issued 5 May 2005
Resolved
Prove proper operation of smoke detector in way of STBD aft berthing area.
Lifesaving › Lifefloat › Float Free
Issued 5 May 2005
Resolved
Install spacers between life floats for proper float free arrangement.
Fire Fighting › Remote Fuel Shutoff › General
Issued 5 May 2005
Resolved
Prove proper operation of STBD F/O remote cut out valve.
Electrical › Electric Supply System (service) › Cable
Issued 19 April 2004
Resolved
Properly dead end un-used wires that have been disconnected from distribution panel located in electrical closet, main deck, aft port side of mian salon dining area.
Lifesaving › Lifejacket/PFD (Type III) › Storage
Issued 7 April 2004
Resolved
Install life jacket stowage placards indicating quantity and size of jackets in their respective storage compartments.
Construction/Loadline › Hull
Issued 25 August 2003
Resolved
Submit proposal to repair as new hull in way of fractured planks and broken frames.
Operations/Management
Issued 25 August 2003
Resolved
Conduct U/W examination of vessel and complete full COI inspection after repairs have been completed to the satisfaction of the attending marine inspector.
Construction/Loadline › Structures
Issued 23 May 2003
Resolved
Remove watertight door in collision bulkhead and restore watertight integrity of collision bulkhead prior to carrying over 32 passengers as allowed SEAMS letter dated 2 March 1983. LEGACY COMPONENT DESC: Transverse Bulkhead
Construction/Loadline › Structures
Issued 23 May 2003
Resolved
Renew wasted grounding bolt doubler block in way of galley bilge.
Electrical › Electric Supply System (service)
Issued 23 May 2003
Resolved
Submit plans for modification of vessel's AC and DC electrical system including installation of power inverter.
Fire Fighting › Fixed CO2 Fire Extinguishing System
Issued 23 May 2003
Resolved
Perform operational test of fixed gas fire extinguishing system. LEGACY COMPONENT DESC: Operating Controls
Engineering › Diesel Engine (propulsion-reduction gear)
Issued 23 May 2003
Resolved
Submit plans for the installation of the new engine control system.
Construction/Loadline › Structures
Issued 23 May 2003
Resolved
Submit plans for the installation of the new stair tower to the upper deck (in way of old dry exhaust stack)
Lifesaving › Lifejacket/PFD (Type I)
Issued 23 May 2003
Resolved
Segregate adult and child PFD's.
Engineering › Diesel Engine (propulsion-reduction gear)
Issued 23 May 2003
Resolved
Submit plans for the installation of the new wet exhaust system for the main propulsion engines.
Lifesaving › Lifejacket/PFD (Type I)
Issued 23 May 2003
Resolved
Label location and quantity of all PFD's. LEGACY COMPONENT DESC: Marking
Pollution Prevention/Response › Prevention Equipment
Issued 23 May 2003
Resolved
Install bilge alarm in forward peak bilge. LEGACY COMPONENT DESC: Bilge Monitor
Construction/Loadline › Structures
Issued 23 May 2003
Resolved
Make all subdivision watertight bulkheads watertight. LEGACY COMPONENT DESC: Transverse Bulkhead
Construction/Loadline › Structures
Issued 23 May 2003
Resolved
Make all deck hatches watertight.
Construction/Loadline › Hull
Issued 23 May 2003
Resolved
Install captive chain on aft watertight hatch.
Fire Fighting › Fire Hydrants
Issued 23 May 2003
Resolved
Label Fire station on upper deck. LEGACY COMPONENT DESC: Location/Position
Accommodation/Occupational Safety › Occupational Safety
Issued 23 May 2003
Resolved
Install rail coursings on all handrails as required by 46 CFR 177.900 LEGACY COMPONENT DESC: Deck Rail
Fire Fighting › Portable Dry Chemical Fire Extinguisher
Issued 23 May 2003
Resolved
Mount all fire extinguishers in approved brackets. LEGACY COMPONENT DESC: Mounting Bracket
Lifesaving › Buoyant Apparatus
Issued 23 May 2003
Resolved
Install weak link on vessel's lifefloats and mount lifefloats to ensure float free status.
Accommodation/Occupational Safety
Issued 23 May 2003
Resolved
Relocate emergency instructions.
Lifesaving
Issued 23 May 2003
Resolved
Post lifejacket placard.
Construction/Loadline › Structures
Issued 23 May 2003
Resolved
Make engine room door watertight and install approved dogging devices. LEGACY COMPONENT DESC: Transverse Bulkhead
Fire Fighting › Fixed Fire Detection System
Issued 23 May 2003
Resolved
Install smoke detectors approved for RV use in all ovenight accommodation spaces. Vessel is restricted from carrying passengers in lower accommodation spaces until satisfied. LEGACY COMPONENT DESC: Smoke Detectors
Electrical › Lighting (emergency)
Issued 23 May 2003
Resolved
Submit plans to install emergency lighting in lower accommodation spaces in accordance with 46 CFR 183.432. vessel is restriced from carrying passengers in lower accommodation spaces until satisfied.
Construction/Loadline › Penetrations
Issued 23 May 2003
Resolved
Renew thru hull fitting doubler-block in way of lazzarette port side aft deck drain. LEGACY COMPONENT DESC: Valve Flange
Engineering › Sea-water System (primary cooling)
Issued 23 May 2003
Resolved
Renew "pedro" (non metallic hose connector) in engine room bilge for piping servicing toilet flushing pump. LEGACY COMPONENT DESC: Piping
Accommodation/Occupational Safety › Occupational Safety
Issued 23 May 2003
Resolved
Submit plans for new upper deck railing. LEGACY COMPONENT DESC: Deck Rail
Engineering › Bilge Water Management System
Issued 23 May 2003
Resolved
Restore vessel's bilge piping to forward peak compartment as required by 46 CFR 182.510. LEGACY COMPONENT DESC: Hose
Engineering › Bilge Water Management System
Issued 23 May 2003
Resolved
Install positive shut off valves at hull penetrations for each electric submersible pump. LEGACY COMPONENT DESC: Valve
Engineering › Bilge Water Management System
Issued 23 May 2003
Resolved
Submit plans for all vessel's new electric submersible bilge pumps including indicator lights at operating station that show when the pumps are running in "automatic mode" LEGACY COMPONENT DESC: Pump
Construction/Loadline › Markings
Issued 23 May 2003
Resolved
Install draft markings on hull as required by 46 CFR 185.602. LEGACY COMPONENT DESC: Draft Marks/Indicating System
Lifesaving › Lifebuoys
Issued 23 May 2003
Resolved
Correctly install retro-reflective tape on all lifering buoys.
Navigation › Collision/Grounding Avoidance
Issued 23 May 2003
Resolved
Show proof the vessel's navigation lights comply with 46 CFR 183.420 (UL 1104 standard) or renew with approved lights. LEGACY COMPONENT DESC: Navigation Lights
Accommodation/Occupational Safety › Medical/First Aid
Issued 23 May 2003
Resolved
Provide USCG approved first aid kit as required by 46 CFR 1884.710
Accommodation/Occupational Safety › Cooking Systems
Issued 23 May 2003
Resolved
Post label on stove "Override switch must be secured when wood counters are installed on stove burners" or remove wood counters from vessel.
Engineering › Fuel Oil Service System
Issued 23 May 2003
Resolved
Renew fuel oil lines in engine room as indicated by attending inspector. New hoses must meet of exceed SAE J1942. LEGACY COMPONENT DESC: Hose
Pollution Prevention/Response › Prevention Equipment
Issued 23 May 2003
Resolved
Renew bilge suction "pedro" located under stair tower to lower accommodation space. LEGACY COMPONENT DESC: Oily Mixture Discharge Fixed Piping System
Accommodation/Occupational Safety › Occupational Safety
Issued 23 May 2003
Resolved
Remove obstruction (carpet) from deck above aft accommodation space emergency egress.
Engineering › Pressure Vessel
Issued 23 May 2003
Resolved
Renew pressure/temperature valve from oil fired hot water heater.
Engineering › Fuel Oil Storage/Transfer System
Issued 23 May 2003
Resolved
Show proof fuel oil tanks are vented as required by 46 CFR 182.450 LEGACY COMPONENT DESC: Vent Pipe
Operations/Management › Drills/Instruction
Issued 23 May 2003
Resolved
Conduct U/W drills in presence of marine inspector.
Accommodation/Occupational Safety › Occupational Safety
Issued 23 May 2003
Resolved
Label emergency egress in engine room and ensure egress hatch is watertight.
Documentation › Certificates/Documents
Issued 23 May 2003
Resolved
Post required documents.
Construction/Loadline › Structures
Issued 23 May 2003
Resolved
Submit proposal to repair isolated wood rot in way of stem and lazzarette. Vessel is placed on a 2 year drydock interval until extend of rot has been determined
Construction/Loadline › Structures
Issued 23 May 2003
Resolved
Submit proposal (plans) to install indicator lights at operating station in watertight doors to show the doors are in the closed position. LEGACY COMPONENT DESC: Door
Construction/Loadline › Structures
Issued 23 May 2003
Resolved
Post sign on watertight doors stating "doors must be secured closed when vessel is underway. LEGACY COMPONENT DESC: Door
Fire Fighting › Fixed CO2 Fire Extinguishing System
Issued 23 May 2003
Resolved
Provide means to have all fixed power ventilation servicing engine room automatically shut down upon activation of fixed gas fire extinguishing system. LEGACY COMPONENT DESC: Operating Controls
Engineering
Issued 23 May 2003
Resolved
Provide information on manufacture of vessels mufflers. Specifically, provide proof the mufflers are made from fireproof/ retardant resins.
Construction/Loadline › Structures
Issued 23 May 2003
Resolved
Make all pvc & plastic piping penetrations of required watertight bulkheads comply with the requirements of 46 CFR 182.40-1(a). Submit proposal for this requirement prior to accomplishing requirement. LEGACY COMPONENT DESC: Transverse Bulkhead
Electrical › Lighting (emergency)
Issued 23 May 2003
Resolved
Install junction box for wiring splice for new "E" lightiing in lower accommodation space. LEGACY COMPONENT DESC: Conductor
Electrical › Electrical Distribution System (service)
Issued 23 May 2003
Resolved
Provide circuit protection for the following conductors: Inverter output, both legs of amp guage from shunt, power conductor for 12 VDC junction block, power conductor for 24 VDC junction block for both 24 VDC battery banks, and battery charger conductors at 12 VDC batteries LEGACY COMPONENT DESC: Circuit Breaker
Electrical › Electrical Distribution System (service)
Issued 23 May 2003
Resolved
Provide circuit protection for the following conductors: conductor for DC power to new engine controls, & conductor for 12 VDC power panel to bridge. LEGACY COMPONENT DESC: Circuit Breaker
Electrical › Electrical Distribution System (service)
Issued 23 May 2003
Resolved
Renew conductor to lazarette bridge using 10 AWG marine cable. LEGACY COMPONENT DESC: Cable
Electrical › Electrical Distribution System (service)
Issued 23 May 2003
Resolved
Renew conductor to mathers controls on bridge sizing conductor as required by 46 CFR.183. LEGACY COMPONENT DESC: Cable
Operations/Management
Issued 23 May 2003
Resolved
Install PA system as required by 46 CFR 184. This requirement must be accommplished prior to carrying passengers for hire. As a substitute the vessel's master may provide a portable electric powered bullhorn to satisfy the PA system requirement until a permanent PA can be installed on the vessel.
Operations/Management › Passenger Operations
Issued 5 August 2002
Resolved
Complete new to zone inspection with [name withheld] prior to carrying passengers.
Communications › Audible Communications
Issued 14 November 2001
Resolved
MISSING PA SYSTEM. CORRECTED
Documentation › Certificates/Documents › Certificate of Documentation (CG-1270)
Issued 14 November 2001
Resolved
COD EXPIRED 12/00. RECEIVED RENEWED COD DATED 28 AUG 01, EXP 30 AUG 02.
Lifesaving › Buoyant Apparatus
Issued 14 November 2001
Resolved
DID NOT HAVE 100% LIFESAVING. NEED TO ACQUIRE LIFE FLOATS TO ACCOMODATE 24 ADDITIONAL PERSONS FOR A TOTAL OF 34.
Construction/Loadline
Issued 30 August 1999
Resolved
PROVE SAT OPERATION OF ALL HIGH LEVEL BILGE ALARMS.
Electrical
Issued 30 September 1998
Resolved
REMOVE DEADENDED WIRING FROM PORT MAIN.
Lifesaving
Issued 30 September 1998
Resolved
2 PFD'S NEED RETRO RENEWED.
Navigation
Issued 30 September 1998
Resolved
PROVIDE CURRENT PUBS (COAST PILOT, LIGHT LIST, NAVRULS).
Engineering
Issued 30 September 1998
Resolved
REPAIR OR REPLACE TACHOMETERS IN E/R.
Lifesaving
Issued 30 September 1998
Resolved
REMOVE OIL FROM DRIP PANS BENEATH MAINS.
Unknown
Issued 9 August 1995
Resolved
VESSEL NOT PARTICIPATING IN RANDOM DRUG TESTING PROGRAM.
Fire Fighting
Issued 9 August 1995
Resolved
ALL FIXED AND PORTABLE FIRE EXTINGUISHERS OVERDUE FOR SERVICING. PORTABLE B-II EXTINGUISHERS DUE FOR HYDRO TESTING. TO BE COMPLETED PRIOR TO THE CARRIAGE OF PASSENGERS.
Documentation
Issued 24 May 1994
Resolved
PROVIDE WRITTEN WASTE MANAGEMENT PLAN.
Construction/Loadline
Issued 24 May 1994
Resolved
PROVE OPERATION OF VESSEL UNDERWAY PRIOR TO THE CARRIAGE OF PASSENGERS.
Engineering
Issued 24 May 1994
Resolved
CLEAN MDE DRIP PANS
Lifesaving
Issued 24 May 1994
Resolved
PROPERLY STOW AND LABEL ALL LIFE JACKETS AND STOWAGE AREAS PRIOR TO THE CARRIAGE OF PASSENGERS.
Construction/Loadline
Issued 24 May 1994
Resolved
EFFECT PERMANENT REPAIRS TO PLANKING ON PORT BOW AND PORT BULWARK
Accommodation/Occupational Safety
Issued 24 May 1994
Resolved
ENSURE PROPER OPERATION AND STENCILING OF EMERGENCY ESCAPE HATCH PRIOR TO THE CARRIAGE OF PASSENGERS.
Documentation
Issued 24 May 1994
Resolved
PROVIDE WRITTEN DRUG TESTING PROGRAM IN ACCORDANCE WITH 46 CFR 16.
Lifesaving
Issued 17 June 1993
Resolved
PROVIDE THREE ADDITIONAL HAND HELD RED FLARES AND 3 ADDITIONAL HAND HELD ORGANGE SMOKES, OR 6 COMBINATION FLARE/SMOKES NO LATER THAN 24JUN93.
Documentation
Issued 17 June 1993
Resolved
HAVE FCC INSPECTION CONDUCTED PRIOR TO 17JUL93.
Engineering
Issued 25 June 1992
Resolved
REPAIR BROKEN RECOR FUEL FILTER HOUSING.
Engineering
Issued 25 June 1992
Resolved
DEMONSTRATE PROPER OPERATION OF BOTH MAIN PROPULSION ENGINES.
Electrical
Issued 25 June 1992
Resolved
CHARGE/ REPLACE DEAD GENSET STARTING BATTERY.
Electrical
Issued 25 June 1992
Resolved
REPAIR LOOSE FIXTURES AND WIRING ON MAIN DECK PORT AND STARBOARD.
Fire Fighting
Issued 25 June 1992
Resolved
SHOW PROOF OF HYDROSTATIC TEST DATE ON FIXED CO2 SYSTEM.
Navigation
Issued 25 June 1992
Resolved
REPAIR SHIPS HORN.
Lifesaving
Issued 25 June 1992
Resolved
LIMITED TO 26 PASSENGERS UNTIL SUCH TIME AS SATISFACTORY NUMBER OF PFD'S ARE PROVIDED.
Unknown
Issued 5 April 1988
Resolved
PROVIDE RELIEF VALVE FOR A/R IN ENGINEROOM.
Documentation
Issued 17 March 1987
Resolved
POST EMERGENCY CHECKLIST.
Engineering
Issued 17 March 1987
Resolved
REPAIR AS NEW BONDING STRAPS FROM COUPLING TO PROP SHAFTS, PORT AND STARBOARD, UNDER DECK AREA OF FORWARD PASSENGER'S CABINS.
Engineering
Issued 17 March 1987
Resolved
INSTALL STOP NUTS ON STARBOARD SHAFT COUPLING, 6:00 POSITION, IN AREA BELOWFORWARD PASSENGER CABIN DECKING.
Documentation
Issued 17 March 1987
Resolved
CORRECT VESSEL DOCUMENT TO REFLECT CURRENT ADDRESS OF OWNERS; TO READ: 10900 N.E. 4TH ST. BELLEVUE, WA 98004
Casualty record · 2
17 July 2003Routine · role: Involved in a Marine Casualty · serious marine incident, as classified · activity 1853112
1 September 2017Routine · role: Involved in a Marine Casualty · serious marine incident, as classified · 1 injured · activity 6282029
Each line is an incident investigation the Coast Guard recorded with this hull among the vessels involved, with the date and the classification the Coast Guard gave it, and the bridge, lock or dam the investigation names where it names one. Involvement is not fault. The investigation narrative is not published. Source: IIR, through 2026.
Ownership record
The Coast Guard's documentation record for this hull -- the Abstract of Title,
with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National
Vessel Documentation Center, files it here with its date, and every reader of this page gets it.