OCEAN MASTER VIII

OCEAN MASTER VIII is a 1983 mobile offshore drilling unit. The Coast Guard has recorded 35 inspections since 1983, most recently in May 2005, along with 83 deficiencies.

Records from 1983 to 2005. Most recent: inspection, 24 May 2005.

Built
1983
Last inspected
24 May 2005
Documentation
Not in the documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

WCX2080
Flag
UNITED STATES
368370000 (licence lapsed)
Maury page id
psix-54853

Inspections, by type

…with no type recorded5
Years with a record 13 calendar years (1983–2005)
The 35 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

This record may be incomplete: the most recent inspection recorded for this vessel was 21 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Offshore class in Maury's sources begin in 1978.

Documentation record

Tonnage as PSIX records it2826 - Regulatory (Subpart C or D), Gross Ton
1780 - Regulatory (Subpart C or D), Net Ton
5117 - Dead Weight, Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.

Radio station licence

WCX2080MMSI 368370000 · expired · compulsorily equipped · granted 13 January 1997, cancelled 17 March 2007
FCC Universal Licensing System ship-station file of 6 September 2026, matched to this hull on its US Official Number. Status and dates are the file’s own. The licensee is not read from the file and is not shown. A lapsed licence’s MMSI is still the number the vessel transmitted under while it was valid.

A report is not offered for this hull: Its record holds only 2 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. Reports.

Inspection history · 35

24 May 2005 Deficiency Check
Physical examination · Activities Europe · Activity 2366717
26 May 1998 Administrative
Administrative · Activities Europe · Activity 791588
20 May 1998 Administrative
Administrative · Activities Europe · Activity 790614
14 March 1998 Re-Inspection · Inclining Experiment
Physical examination · Activities Europe · Activity 1424543
6 February 1998 Deficiency Check
Physical examination · Activities Europe · Activity 1107668
17 October 1997 Administrative
Administrative · Activities Europe · Activity 1111071
26 February 1997 Administrative
Administrative · Activities Europe · Activity 1098541
31 January 1997 Deficiency Check
Physical examination · Activities Europe · Activity 1101572
20 January 1997 Deadweight Survey · Hull Examination · COI Inspection
Physical examination · Activities Europe · Activity 1357857
27 May 1995 MARPOL Annex V Examination · COI Inspection · Deficiency Check
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 874683
29 October 1994 Hull Examination · MARPOL Annex V Examination
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1174726
29 October 1994 Hull Examination · MARPOL Annex V Examination
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1175696
15 July 1994 Deficiency Check
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 864648
17 May 1994 Drydock Extension · MARPOL Annex V Examination · Re-Inspection
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1180124
29 June 1993 Deficiency Check
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1152620
8 May 1993 COI Inspection
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1152897
6 January 1993 Administrative
Administrative · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 829043
15 September 1992 Deficiency Check
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1259564
14 September 1992 Type not recorded
No type recorded · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 949129
30 June 1992 Deficiency Check
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1264511
1 June 1992 Hull Examination · Deficiency Check
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 948439
20 May 1992 Administrative
Administrative · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 959160
29 April 1992 Re-Inspection
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 957678
2 August 1991 Administrative
Administrative · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1244952
12 April 1991 COI Inspection
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1211336
25 November 1990 Type not recorded
No type recorded · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 919254
11 April 1990 Administrative
Administrative · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 918241
9 April 1990 Re-Inspection
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1230624
9 April 1989 Deficiency Check · COI Inspection
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1235604
7 April 1989 Hull Examination
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1037816
11 May 1987 Administrative
Administrative · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1329035
14 April 1987 Administrative
Administrative · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1323635
16 May 1985 Type not recorded
No type recorded · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 982389
15 May 1985 Type not recorded
No type recorded · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1293753
5 April 1983 Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 966674

Deficiency record · 83

Documentation › Certificates/Documents › Certificate of Documentation (CG-1270)
Issued 14 March 1998 Resolved
Provide MIO Europe with proof of a valid Certificate of Documentation._x001C_ (Vessel may not operate until above requirement is cleared).
Condition: Unknown
Due 14 May 1998
Resolved 24 May 2005
Resolution: VESSEL REFLAGGED TO MARSHALL ISLANDS ALL DEF''S CLEARED.
Electrical › Electric Generation Source (emergency) › Switch
Issued 14 March 1998 Resolved
Repair Emergency shutdown to Emergency Generator.
Condition: Unknown
Due 14 May 1998
Resolved 24 May 2005
Resolution: VESSEL REFLAGGED TO MARSHALL ISLANDS ALL DEF''S CLEARED.
Engineering › Diesel Engine (auxiliary) › Air Silencer
Issued 14 March 1998 Resolved
Reduce fire main pressure to 125 PSI.
Condition: Unknown
Due 14 May 1998
Resolved 24 May 2005
Resolution: VESSEL REFLAGGED TO MARSHALL ISLANDS ALL DEF''S CLEARED.
Electrical › Electrical Distribution System (emergency) › Busway
Issued 14 March 1998 Resolved
Install regulator and pressure gauge to Main Engine Alarm Panel on drill floor.
Condition: Unknown
Due 14 May 1998
Resolved 24 May 2005
Resolution: VESSEL REFLAGGED TO MARSHALL ISLANDS ALL DEF''S CLEARED.
Documentation
Issued 17 October 1997 Resolved
As per G-MSC-1 letter dated 18SEP97 conduct an inclining experiment OR submit to G-MSC-1 information to substantiate an indisputably conservative estimate of vertical center of gravity (VCG).
Condition: Unknown
Due 17 October 1997
Resolved 17 October 1997
Engineering
Issued 20 January 1997 Resolved
Test overspeed, low-lube oil and reverse power trips/alarms on #1 and #2 generators. OIM may fax statment of satisfactory test to MIO Europe in order to clear this requirement.
Condition: Unknown
Due 20 January 1997
Resolved 20 January 1997
Engineering
Issued 20 January 1997 Resolved
Test rig shutdown from control room and drill floor. OIM may fax statementto MIO Europe attesting to satisfactory operation in order to clear this requirement.
Condition: Unknown
Due 20 January 1997
Resolved 20 January 1997
Lifesaving
Issued 27 May 1995 Resolved
CONDUCT END FOR END OF BOTH LIFEBOAT FALLS AND CONDUCT WEIGHT TEST OR REPLACE FALLS AND CONDUCT WEIGHT TEST, INCLUDING LIFERAFT FALLS.
Condition: Unknown
Due 2 June 1995
Resolved 2 June 1995
Fire Fighting
Issued 27 May 1995 Resolved
SERVICE FIXED FIRE EXTINGUISHING EQUIPMENT.
Condition: Unknown
Due 2 June 1995
Resolved 2 June 1995
Fire Fighting
Issued 27 May 1995 Resolved
REPLACE DEFECTIVE DRY CHEMICAL (PORTABLE) EXTINGUISHER PORT SIDE SKID AREA;SERVICE ALL PORTABLES.
Condition: Unknown
Due 2 June 1995
Resolved 2 June 1995
Unknown
Issued 29 October 1994 Resolved
PROVIDE UNDER WATER HULL SURVEY VIDEO AND REPORT FROM NAVAL DIVERS.
Condition: Unknown
Due 29 October 1994
Resolved 29 October 1994
Documentation
Issued 17 May 1994 Resolved
PROVIDE LTR STATING OFFSHORE INSTALLATION MGR DESIGNATED.
Condition: Unknown
Due 25 October 1994
Resolved 25 October 1994
Lifesaving
Issued 17 May 1994 Resolved
PROVIDE 7 ADDITIONAL COAST GUARD APPROVED LIFE JACKETS INCLUDING LIGHTS, WHISTLE & VESSEL NAME. VSL'S TOTAL PERSONS ALLOWED IS REDUCED TO 82 TILL REQT CLEARED._x001C_
Condition: Unknown
Due 13 September 1994
Resolved 13 September 1994
Deck/Cargo
Issued 17 May 1994 Resolved
PROVE THAT VSL IS NOT REQUIRED TO CARRY ANCHORS.
Condition: Unknown
Due 17 May 1994
Resolved 17 May 1994
Documentation
Issued 17 May 1994 Resolved
PROVIDE ORIGINAL ABS CLASSIFICATION CERTIFICATE.
Condition: Unknown
Due 17 May 1994
Resolved 17 May 1994
Documentation
Issued 17 May 1994 Resolved
PROVIDE/PROVE FOUR CERTIFIED LIFEBOATMEN AS PER COI.
Condition: Unknown
Due 17 May 1994
Resolved 17 May 1994
Fire Fighting
Issued 17 May 1994 Resolved
PROVIDE/PROVE HYDRO DATES ON ALL SIX B-V SEMI PORTABLE FIRE EXTINGUISHERS ON HELO DECK AREA.
Condition: Unknown
Due 17 May 1994
Resolved 17 May 1994
Navigation
Issued 17 May 1994 Resolved
PROVER PROPER OPERATION OF EMERGENCY RADIO.
Condition: Unknown
Due 25 October 1994
Resolved 25 October 1994
Lifesaving
Issued 1 June 1992 Resolved
REINSTALL ALL DOOR LATCHES IN THE ACCOMMODATION SPACES AND DOORS LEADING TOWEATHER DECKS._x001C_ _x001C_ REQT REISSUED TO REPLACE ONE ORIGINALLY ISSUED ON 29APR92._x001C_
Condition: Unknown
Due 1 June 1992
Resolved 1 June 1992
Construction/Loadline
Issued 1 June 1992 Resolved
CROP AND RENEW TO GOOD METAL BOTTOM PLATING AND SIDESHELL THAT IS SET-IN IN#13 DRILL WATER TANK. THIS ITEM IS TO BE CLEARED BY THE SUBMITTAL OF A COPYOF THE ABS REPAIR SURVEY REPORT._x001C_ _x001C_
Condition: Unknown
Due 1 June 1992
Resolved 1 June 1992
Documentation
Issued 1 June 1992 Resolved
PROVIDE COPY OF DIVING REPORT FOR UNDERWAY SURVEY CONDUCTED BETWEEN 30MAY AND 1 JUNE 1992.
Condition: Unknown
Due 28 September 1992
Resolved 28 September 1992
Unknown
Issued 29 April 1992 Resolved
PROVIDE VESSEL'S CONSTRUCTION PORTFOLIO FOR U.S. COAST GUARD REVIEW, DURINGNEXT DRYDOCK EXAMINATION.
Condition: Unknown
Due 29 April 1992
Resolved 29 April 1992
Electrical
Issued 29 April 1992 Resolved
INSTALL ELECTRICAL GRADE MATTING FOR SWITCHBOARDS IN THE CONTROL ROOM AND EMERGENCY GEN. ROOM AS PER 46 CFR 111.30.11.
Condition: Unknown
Due 29 April 1992
Resolved 29 April 1992
Lifesaving
Issued 29 April 1992 Resolved
REPLACE MISSING FWD. LIMIT SWITCH ACTIVATING ROD FOR PORT LIFE BOAT DAVIT AND PROVE PROPER OPERATION OF SAME, TO THE SATISFACTION OF ATTENDING USCG INSPECTOR.
Condition: Unknown
Due 29 April 1992
Resolved 29 April 1992
Construction/Loadline
Issued 29 April 1992 Resolved
ADJUST AND CONDUCT A CHALK TEST ON THE FOLLOWING DOORS: (1) WATERTIGHT DOOR BY FIRE STA.2, (2)WATERTIGHT DOOR BY #1 GEN. (3)WATERTIGHT DOOR BY #3 GEN. FROM PUMPROOM (4)ALL 3 MUD PIT DOORS. CHALK TEST TO BE DONE TO THE SATISFACTION OF ATTENDING USCG INSPECTOR.
Condition: Unknown
Due 29 April 1992
Resolved 29 April 1992
Fire Fighting
Issued 29 April 1992 Resolved
REPLACE ALL FIRE HOSES THAT ARE NOT UL LISTED WITH UL LISTED FIREHOSES.
Condition: Unknown
Due 29 April 1992
Resolved 29 April 1992
Electrical
Issued 29 April 1992 Resolved
PROVE PROPER OPERATION OF OVERSPEED TRIP, LOW LUBE OIL AND HIGH TEMP. TRIPSINCLUDING REVERSE POWER RELAY FOR #4 GEN., TO THE SATISFACTION OF ATTENDINGUSCG INSPECTOR.
Condition: Unknown
Due 29 April 1992
Resolved 29 April 1992
Construction/Loadline
Issued 29 April 1992 Resolved
CROP AND RENEW TO GOOD METAL IN WAY OF SET-IN, #13 DRILL WATER TANK WHERE SIDESHELL MEETS THE BOTTOM PLATE, BAY 2. REPAIRS TO BE IN ACCORDANCE WITH_x001C_CONSTRUCTION PORTFOLIO AND TO THE SATISFACTION OF USCG INSPECTOR, DURING NEXT DRYDOCKING EXAM. BUT NO LATER THAN 30JUL92.
Condition: Unknown
Due 29 April 1992
Resolved 29 April 1992
Accommodation/Occupational Safety
Issued 29 April 1992 Resolved
INSTALL "MAN LOCKED IN FREEZER" ALARM TO SOUND IN A NORMALLY MANNED SPACE IN ACCORDANCE WITH 46 CFR 113.45, AND PROVE PROPER OPERATION TO SATISFACTION OF ATTENDING USCG INSPECTOR.
Condition: Unknown
Due 29 April 1992
Resolved 29 April 1992
Lifesaving
Issued 29 April 1992 Resolved
PROVIDE THE FOLLOWING FOR THE PORT LIFEBOAT: LIGHT FOR COMPASS, 2 HEAVING LINES, 5 LBS OF RATIONS AND 59 PACKETS OF WATER. ALL ABOVE ITEMS ARE TO BE U.S. COAST GUARD APPROVED.
Condition: Unknown
Due 29 April 1992
Resolved 29 April 1992
Lifesaving
Issued 29 April 1992 Resolved
PROVIDE THE FOLLOWING FOR THE STBD LIFEBOAT: LIGHT FOR COMPASS, 21 LBS OF RATIONS AND 63 PACKETS OF WATER.
Condition: Unknown
Due 29 April 1992
Resolved 29 April 1992
Lifesaving
Issued 29 April 1992 Resolved
[withheld — contains personal information; the deficiency system, dates, and resolution status are shown above]
Condition: Unknown
Due 29 April 1992
Resolved 29 April 1992
Fire Fighting
Issued 29 April 1992 Resolved
REINSTALL ALL DOOR LATCHES IN THE ACCOMMODATION SPACES AND DOORS LEADING TOWEATHER DECKS.
Condition: Unknown
Due 29 April 1992
Resolved 29 April 1992
Unknown
Issued 29 April 1992 Resolved
REPLACE MISSING PA SYSTEM LOUDSPEAKER OUTBOARD OF #1 GEN. AND PROVE PROPER OPERATION OF SAME, TO THE SATISFACTION OF ATTENDING USCG INSPECTOR.
Condition: Unknown
Due 29 April 1992
Resolved 29 April 1992
Lifesaving
Issued 29 April 1992 Resolved
PROVIDE H2S TEST GAS AND PROVE PROPER OPERATION OF H2S ALARM SYSTEM, TO THESATISFACTION OF ATTENDING USCG INSPECTOR.
Condition: Unknown
Due 22 May 1992
Resolved 22 May 1992
Fire Fighting
Issued 29 April 1992 Resolved
HAVE ALL PORTABLE FIRE EXTINGUISHERS HYDROTESTED AND REFILLED AT A U.S. DOTAPPROVED FACILITY. PROVIDE [name withheld] A COPY OF HYDRO TEST CERTIFICATE,NO LATER THAN 30 MAY 92.
Condition: Unknown
Due 29 April 1992
Resolved 29 April 1992
Lifesaving
Issued 12 April 1991 Resolved
PROVIDE 44LBS OF CONDENSED MILK AND ONE ADDITIONAL BOATHOOK IN THE PORT ANDSTARBOARD LIFEBOATS. THE ABOVE REQUIREMENT MAY BE MET BY PROVIDING [name withheld] WITH COPIES OF THE INVOICES FOR THE ABOVE ITEMS AND A SIGNED STATEMENT BY THE [name withheld] ARRIVAL AND INSTALLATION.
Condition: Unknown
Due 12 April 1991
Resolved 12 April 1991
Lifesaving
Issued 12 April 1991 Resolved
RENEW PORT AND STARBOARD LIFEBOAT FALLS AND PORT AND STARBOARD LIFERAFT DAVIT FALLS. THE ABOVE REQQUIREMENT MAY BE MET BY PROVIDE [name withheld] WITH COPIES OF THE WIRE ROPE CERTIFICATES AND A SIGNED STATEMENT BY THE [name withheld] INSTALLATION.
Condition: Unknown
Due 12 April 1991
Resolved 12 April 1991
Documentation
Issued 12 April 1991 Resolved
PROVIDE DOCUMENTATION THAT A CRANE RECORD BOOK IS BEING MAINTAINED ABOARD THE VESSEL AS OUTLINED IN 46 CFR109.437. THE ABOVE REQUIREMENT MAY BE MET BY PROVIDING [name withheld] WITH A COPY OF THE ABOVE RECORD BOOK.
Condition: Unknown
Due 12 April 1991
Resolved 12 April 1991
Lifesaving
Issued 12 April 1991 Resolved
PROVIDE ONE 1,500 FT AUXILIARY LINE WITH A MINIMUM BREAKING STRENGTH OF AT LEAST 9,000 PDS FOR THE LINE-THROWING APPLIANCE. THE ABOVE REQUIREMENT MAY BE MET BY PROVIING [name withheld] WITH AN INVOICE COPY FOR THE LINE & A SIGNEDSTATEMENT BY THE [name withheld] TO THE FACT THAT THE LINE IS ON THE VSL.
Condition: Unknown
Due 12 April 1991
Resolved 12 April 1991
Navigation
Issued 12 April 1991 Resolved
PROVIDE A DUMMY LOAD TO ALLOW PROPER TESTING OF THE PORTABLE EMERGENCY RADIO. THE ABOVE REQUIREMENT MAY BE MET BY PROVIDING [name withheld] WITH A COPY OF THE INVOICE AND A SIGNED STATEMENT BY THE [name withheld] TO THE FACT THAT THE ABOVE ITEM IS ON THE VESSEL.
Condition: Unknown
Due 12 April 1991
Resolved 12 April 1991
Documentation
Issued 12 April 1991 Resolved
PROVIDE DOCUMENTATION ON THE PORT AND DATE THE VESSEL CONSTRUCTION PORTFOLIO WAS APPROVED BY THE USCG. THE ABOVE REQUIREMENT MAY BE MET BY PROVIDING [name withheld] WITH A COPY OF THE APPROVAL STAMP.
Condition: Unknown
Due 12 April 1991
Resolved 12 April 1991
Fire Fighting
Issued 12 April 1991 Resolved
PROVE PROPER OPERATION OF THE GENERAL ALARM BEELL IN THE MUD PIT ROOM; THISBELL LOCATED IN A CLASSIFIED AREA AND IS REQUIRED TO BE RATED CLLASS 1 DIV 1. ABOVE REQUIREMENT TO BE MADE TO THE STAISFACTION OF AN ATTENDING USCG MARINE INSPECTOR.
Condition: Unknown
Due 12 April 1991
Resolved 12 April 1991
Electrical
Issued 12 April 1991 Resolved
PROVE PROPER OPERATION OF NUMBER ONE AND TWO MAIN SERVICE GENERATORS DIESELOVERSPEED TRIPS TO THE SATISFATION OF AN ATTENDING USCG MARINE INSPECTOR.
Condition: Unknown
Due 12 April 1991
Resolved 12 April 1991
Accommodation/Occupational Safety
Issued 12 April 1991 Resolved
INSTALL A 50MAWP RELIEF VALVE,CAPABLE OF BEING HAND RELIEVED, ON BULK TANK #16896. NOT TO BE PRESSURIZED UNTIL RELIEF VALVE IS INSTALLED. THE ABOVE REQUIREMENT MAY BE MET BY PROVIDING [name withheld] WITH A COPY OF THE VALVE INVOICE AND A SIGNED STATEMENT BY THE BARGE [name withheld] THAT THE ABOVE
Condition: Unknown
Due 12 April 1991
Resolved 12 April 1991
Accommodation/Occupational Safety
Issued 12 April 1991 Resolved
PROVE PROPER OPERATION OF THE METHANE AND H2S DETECTION SYSTEM TO THE SATISFACTION OF AN ATTENDING USCG MARINE INSPECTOR.
Condition: Unknown
Due 12 April 1991
Resolved 12 April 1991
Documentation
Issued 12 April 1991 Resolved
PROVIDE DOCUMENTATION, IN WRITING, DESIGNATING THE PERSON IN CHARGE AND ALLCRANE OPERATORS AS OUTLINED IN 46 CFR 109.107 AND 46 CFR 109.527. THE ABOVE REQUIREMENT MAY BE MET BY PROVIDING [name withheld] WITH SIGNED COPIES OF THE DESIGNATION LETTERS.
Condition: Unknown
Due 12 April 1991
Resolved 12 April 1991
Documentation
Issued 12 April 1991 Resolved
PROVIDE A COPY OF THE CURRENT DOCUMENT OF CERTIFICATION DECAL TO [name withheld].
Condition: Unknown
Due 12 April 1991
Resolved 12 April 1991
Documentation
Issued 12 April 1991 Resolved
PROVIDE A COPY OF THE CURRENT CARGO GEAR CERTIFICATE TO [name withheld].
Condition: Unknown
Due 12 April 1991
Resolved 12 April 1991
Fire Fighting
Issued 12 April 1991 Resolved
HYDROSTATICALLY TEST,AT A DOT APPROVED FACILITY,THE NITROGEN CYLINDERS FOR THE 3 HELO DECK SEMI-PORTABLE FIRE EXTINGUISHERS. THE ABOVE REQUIREMENT MAYBE MET BY PROVIDING [name withheld] WITH A COPY OF THE HYDRO CERTIFICATE & A SIGNEDSTATEMENT BY THE [name withheld] ARE ON THE VSL AND REINSTALL
Condition: Unknown
Due 12 April 1991
Resolved 12 April 1991
Lifesaving
Issued 12 April 1991 Resolved
DAVIT LAUNCHED LIFERAFTS NUMBER 3 AND 4 TO BE SERVICED AT AN APPROVED LIFERAFT SERVICING FACILITY IN THE PRESENCE OF AN ATTENDING MARINE INSPECTOR. THE ABOVE REQUIREMENT MAY BE MET BY PROVIDING [name withheld] WITH COPIES OF THE SERVICING REPORT.
Condition: Unknown
Due 12 April 1991
Resolved 12 April 1991
Lifesaving
Issued 9 April 1990 Resolved
PROVIDE FOR HYDROSTATIC TESTING AT AN APPROVED D.O.T. FACILITY OF ALL SIX (6) PORT AND STARBOARD LIFEBOAT AIR BOTTLES.
Condition: Unknown
Due 9 April 1990
Resolved 9 April 1990
Fire Fighting
Issued 9 April 1990 Resolved
HAVE ALL VESSELS 15LB CO2 PORTABLES HYDROSTATICALLY TESTED AT APPROVED D.O.T. FACILITY.
Condition: Unknown
Due 9 April 1990
Resolved 9 April 1990
Fire Fighting
Issued 9 April 1990 Resolved
PROPERLY MOUNT WITH USCG APPROVED MARINE TYPE BRACKETS (2) TWO 15LB CO2 BOTTLES PORT SIDE OF CONTROL ROOM UPPER DECK.
Condition: Unknown
Due 9 April 1990
Resolved 9 April 1990
Fire Fighting
Issued 9 April 1990 Resolved
HAVE ALL OF VESSELS PORTABLE, SEMI-PORTABLE AND FIXED FIRE EXTINGUISHERS AND SYSTEMS SERVICED AND TESTED. UPON COMPLETION, [name withheld] TO BE PROVIDED WITH SATISFACTORY CERTIFICATES.
Condition: Unknown
Due 9 April 1990
Resolved 9 April 1990
Accommodation/Occupational Safety
Issued 9 April 1990 Resolved
REPAIR DRILLERS CONSOUL PURGE AIR SYSTEM TO PROPER OPERATION.
Condition: Unknown
Due 9 April 1990
Resolved 9 April 1990
Electrical
Issued 9 April 1990 Resolved
PROVE PROPER OPERATION OF REVERSE POWER RELAYS ON GENERATORS (3) THREE, (4) FOUR, AND (5) FIVE OR EMERGENCY GENERATOR.
Condition: Unknown
Due 9 April 1990
Resolved 9 April 1990
Lifesaving
Issued 9 April 1990 Resolved
RENEW BOTH EXPIRED SELF ACTIVATING SMOKE SIGNALS, APPROVED UNDER 46 CFR 160.057 AT THE LAUNCHABLE RING BUOY STATIONS.
Condition: Unknown
Due 9 April 1990
Resolved 9 April 1990
Electrical
Issued 9 April 1989 Resolved
PROVE PROPER OPERATION OF ALL H2S AND COMBUSTIBLE GAS SENSORS AND ALARMS.
Condition: Unknown
Due 9 April 1989
Resolved 9 April 1989
Accommodation/Occupational Safety
Issued 9 April 1989 Resolved
MAKE PERMANENT REPAIRS TO RAW WATER COOLING FIXED PIPING FOR A/C COMPRESSORS, STARBOARD SACK STORES.
Condition: Unknown
Due 9 April 1989
Resolved 9 April 1989
Lifesaving
Issued 9 April 1989 Resolved
RENEW 12 CG APPROVED RED PARACHUTE FLARES IN THE CONTROL ROOM.
Condition: Unknown
Due 9 April 1989
Resolved 9 April 1989
Lifesaving
Issued 9 April 1989 Resolved
RENEW 4 CARTRIDGES AND 4 ROCKET PROJECTILES FOR LINE THROWING GUN.
Condition: Unknown
Due 9 April 1989
Resolved 9 April 1989
Fire Fighting
Issued 9 April 1989 Resolved
PROVIDE FOR EACH OF THE TWO FIREMEN'S OUTFITS AN OXYGEN AND EXPLOSIVE METERLISTED BY UNDERWRITER'S LABORATORIES INC. OR FACTORY MUTUAL AS EXPLOSION PROOF AND A SELF-CONTAINED BREATHING APPARATUS.
Condition: Unknown
Due 9 April 1989
Resolved 9 April 1989
Lifesaving
Issued 9 April 1989 Resolved
PROVE PROPER OPERATION OF EMBARKATION LADDERS.
Condition: Unknown
Due 9 April 1989
Resolved 9 April 1989
Construction/Loadline
Issued 9 April 1989 Resolved
PROVE PROPER OPERATION OF MUD PIT ROOM DOOR CLOSURE DEVICES.
Condition: Unknown
Due 9 April 1989
Resolved 9 April 1989
Lifesaving
Issued 9 April 1989 Resolved
PROVIDE FOLLOWING EQUIP FOR STBD MOTOR L/B: LIGHTS ON LIFEJACKETS, ASPIRIN,COMPASS LIGHTSTICKS,132 QTS WATER,88 LBS PROVISIONS,44 LBS SWEETENED COND MILK,FLASHLIGHT,FISHING KIT,12 RED FLARES EA. PARACHUTE & HANDHELD,2 FLOAT-ING ORANGE SMOKE SIGNALS ALL CG APPROVED,VSL NAME ON L/J & SERVICE COMPASS.
Condition: Unknown
Due 9 April 1989
Resolved 9 April 1989
Lifesaving
Issued 9 April 1989 Resolved
PROVIDE EQUIP FOR PORT MOTOR L/B:LIFEJACKET LIGHTS&WHISTLES,ASPIRIN,COMPASSLIGHTSTICKS,FLASHLIGHT,FISHING KIT,12 RED FLARES EA.PARACHUTE & HANDHELD,2 FLOATING ORANGE SMOKE SIGNALS,132QTS WATER,88LBS PROVISIONS,44LBS SWEETENEDCOND.MILK ALL CG APPROVED.SERVICE COMPASS & AFT PORTABLE FIRE EXTINGUISHER.
Condition: Unknown
Due 9 April 1989
Resolved 9 April 1989
Lifesaving
Issued 9 April 1989 Resolved
SERVICE ALL INFLATABLE LIFERAFTS.
Condition: Unknown
Due 9 April 1989
Resolved 9 April 1989
Lifesaving
Issued 9 April 1989 Resolved
REPLACE SIX (6) RING BUOYS.
Condition: Unknown
Due 9 April 1989
Resolved 9 April 1989
Construction/Loadline
Issued 9 April 1989 Resolved
REPAINT ALL VESSEL HULL MARKINGS.
Condition: Unknown
Due 9 April 1989
Resolved 9 April 1989
Lifesaving
Issued 9 April 1989 Resolved
PROVIDE 110 CG APPROVED LIGHTS FOR LIFEJACKETS.
Condition: Unknown
Due 9 April 1989
Resolved 9 April 1989
Lifesaving
Issued 9 April 1989 Resolved
RENEW BOTH EXPIRED SELF-ACTIVATING SMOKE SIGNALS, APPROVED UNDER 46 CFR 160.057 AT THE LAUNCHABLE RING BUOY STATIONS.
Condition: Unknown
Due 9 April 1989
Resolved 9 April 1989
Documentation
Issued 7 April 1989 Resolved
PROVIDE DIVERS REPORT FOR UNDERWATER HULL SURVEY TO [name withheld],
Condition: Unknown
Due 7 April 1989
Resolved 7 April 1989
Lifesaving
Issued 16 May 1985 Resolved
RENEW BOTH EXPIRED SELF ACTIVATING SMOKE SIGNALS (APPROVED UNDER 46 CFR 160.057) AT THE LAUNCHABLE RING BUOY STATIONS.
Condition: Unknown
Due 16 May 1985
Resolved 16 May 1985
Fire Fighting
Issued 16 May 1985 Resolved
PROVIDE FOR EACH OF THE 2 FIREMAN'S OUTFITS AN OXYGEN METER LISTED BY FM/ CSA/UL AS EXPLOSION PROOF.
Condition: Unknown
Due 16 May 1985
Resolved 16 May 1985
Accommodation/Occupational Safety
Issued 16 May 1985 Resolved
A RELIEF VALVE MEETING THE REQUIREMENTS OF 46 CFR 54.15 SHALL BE INSTALLED ON EACH OF THE (2) SANITARY HEAD TANKS.
Condition: Unknown
Due 16 May 1985
Resolved 16 May 1985
Lifesaving
Issued 16 May 1985 Resolved
EITHER PROVIDE ON BOARD THE VESSEL 12 HAND-HELD ROCKET PROPELLED, PARACHUTERED FLARES (MEETING 46 CFR 160.36) OR PROVIDE ON BOARD THE U.S. COAST GUARD APPROVED GUN (46 CFR 160.028/10/2) FOR THIS RED PARACHUTE DISTRESS FLARES (PRESENTLY ON BOARD).
Condition: Unknown
Due 16 May 1985
Resolved 16 May 1985
Unknown
Issued 5 April 1983 Resolved
(REQUIREMENT 2 CONTINUED) HAVE BEEN PURGED WITH A MINIMUM OF FOUR AIR CHANGES AS PER NFPA 496 PART 23.
Condition: Unknown
Due 5 April 1983
Resolved 5 April 1983
Lifesaving
Issued 5 April 1983 Resolved
PROVIDE FOUR MORE QUARTS OF DRINKING WATER IN THE STARBOARD LIFEBOAT FOR A TOTAL OF NINE QUARTS PER PERSON AS PER 46 CFR 94.20-15(JJ).
Condition: Unknown
Due 5 April 1983
Resolved 5 April 1983
Unknown
Issued 5 April 1983 Resolved
THE FOLLOWING DEFICIENCIES PERTAIN TO THE VESSEL OCEAN MASTER VIII, DN654598.
Condition: Unknown
Due 5 April 1983
Resolved 5 April 1983
Electrical
Issued 5 April 1983 Resolved
PROVIDE ENGINE ALARMS FOR MAIN GENERATORS AND THE EMERGENCY GENERATOR AS REQUIRED BY 46 CFR 111.10-5 AND 112.50-1 AND UNTIL SUCH ALARMS ARE
Condition: Unknown
Due 5 April 1983
Resolved 5 April 1983
Unknown
Issued 5 April 1983 Resolved
(REQUIREMENT 1 CONTINUED) INSTALLED AND OPERATIONAL, A CONTINUOUS LIVE WATCH PER ENGINE ON THE LINE SHALL BE PROVIDED
Condition: Unknown
Due 5 April 1983
Resolved 5 April 1983
Electrical
Issued 5 April 1983 Resolved
REPAIR OR REPLACE THE TIME DELAY PRESSURE SWITCH WHICH ASSURES AIR PURGED ENCLOSURES ON THE DRILL FLOOR CANNOT BE ENERGIZED UNTIL SUCH ENCLOSURES
Condition: Unknown
Due 5 April 1983
Resolved 5 April 1983

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.