MAURY USCG vessel records Sign in
← All vessels

ROSE LUMMIS

ROSE LUMMIS is a 1953 passenger vessel (inspected). The Coast Guard has recorded 41 inspections since 1985, most recently in August 2026, along with 92 deficiencies and 1 casualty investigation in 2017.

Records from 1985 to 2026. Most recent: inspection, 20 August 2026.

Built
1953
Last inspected
20 August 2026
Documentation
Valid · documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

WDA9552
Flag
UNITED STATES
366866440, 367734370 (licence lapsed)
Maury page id
psix-54858

Inspections, by type

…with no type recorded4
Years with a record 27 calendar years (1985–2026)
The 41 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 1977.

Documentation record

Registered dimensions (L × B × D)49.2 ft × 13.0 ft × 3.2 ft
Registered tonnagegross 14 / net 9
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderKELLY SHOP INC · JEFFERSONVILLE, IN, UNITED STATES · built 1953
Hull materialSteel
PropulsionDiesel Reduction
Hull shapeNot recorded
Hull configurationNot recorded
Hailing portSODUS BAY, NY
Trade endorsementsCoastwise, unrestricted
DocumentationValid · issued 18 August 2026 · expires 31 August 2027
Service, as the file records itPassenger (Inspected)
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it14 - Regulatory (Subpart C or D), Gross Ton
9 - Regulatory (Subpart C or D), Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 September 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.

Radio station licence

WDI8005MMSI 367734370 · expired · compulsorily equipped · granted 17 May 2016, cancelled 27 June 2026
WDA9552MMSI 366866440 · expired · compulsorily equipped · granted 22 August 2002, cancelled 27 October 2012
FCC Universal Licensing System ship-station file of 6 September 2026, matched to this hull on its US Official Number. Status and dates are the file’s own. The licensee is not read from the file and is not shown. A lapsed licence’s MMSI is still the number the vessel transmitted under while it was valid.

Inspection history · 41

20 August 2026 In-Service Inspection
Physical examination · Sector Eastern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 8468810
17 July 2026 Annual Inspection
Physical examination · Sector Eastern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 8445576
22 August 2025 In-Service Inspection
Physical examination · Sector Eastern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 8215947
7 May 2025 Drydock Exam · Administrative Inspection · COI Inspection · Internal Structural Exam
Physical examination · Sector Eastern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 8133114
2 July 2024 Administrative Inspection · Annual Inspection
Physical examination · Marine Safety Unit Sturgeon Bay · USCG Great Lakes District (CGD-GL) · Activity 7955441
28 June 2023 Administrative Inspection · Annual Inspection
Physical examination · Marine Safety Unit Sturgeon Bay · USCG Great Lakes District (CGD-GL) · Activity 7727399
5 May 2023 Damage Survey
Physical examination · Marine Safety Unit Sturgeon Bay · USCG Great Lakes District (CGD-GL) · Activity 7681914
16 May 2022 Annual Inspection · Administrative Inspection
Physical examination · Marine Safety Unit Sturgeon Bay · USCG Great Lakes District (CGD-GL) · Activity 7452737
26 May 2021 Administrative Inspection · COI Inspection
Physical examination · Marine Safety Unit Sturgeon Bay · USCG Great Lakes District (CGD-GL) · Activity 7220314
20 April 2021 Internal Structural Exam · Examination of Repairs · Drydock Exam
Physical examination · Marine Safety Unit Sturgeon Bay · USCG Great Lakes District (CGD-GL) · Activity 7179299
8 April 2021 Administrative Inspection
Administrative · Marine Safety Unit Sturgeon Bay · USCG Great Lakes District (CGD-GL) · Activity 7173844
16 July 2020 Annual Inspection
Physical examination · Marine Safety Unit Sturgeon Bay · USCG Great Lakes District (CGD-GL) · Activity 7008763
6 March 2019 Administrative Inspection · Annual Inspection
Physical examination · Marine Safety Unit Sturgeon Bay · USCG Great Lakes District (CGD-GL) · Activity 6684227
10 May 2018 Annual Inspection · Administrative Inspection
Physical examination · Marine Safety Unit Sturgeon Bay · USCG Great Lakes District (CGD-GL) · Activity 6418011
8 May 2018 Administrative Inspection
Administrative · Marine Safety Unit Sturgeon Bay · USCG Great Lakes District (CGD-GL) · Activity 6409432
11 July 2017 Administrative Inspection
Administrative · Marine Safety Unit Sturgeon Bay · USCG Great Lakes District (CGD-GL) · Activity 6208925
21 June 2017 Type not recorded
No type recorded · Marine Safety Unit Sturgeon Bay · USCG Great Lakes District (CGD-GL) · Activity 6204224
10 May 2017 Annual Inspection
Physical examination · Marine Safety Unit Sturgeon Bay · USCG Great Lakes District (CGD-GL) · Activity 6143764
1 January 2017 Administrative Inspection
Administrative · Marine Safety Unit Sturgeon Bay · USCG Great Lakes District (CGD-GL) · Activity 6123987
12 November 2015 Administrative Inspection
Administrative · Sector Eastern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 5761959
7 October 2015 DAPI Audit · Damage Survey · Deficiency Check · Hull Examination · COI Inspection · Plan Review "T" Boat · Administrative Inspection · Simplified Stability Test · Examination of Repairs
Physical examination · Marine Safety Unit Sturgeon Bay · USCG Great Lakes District (CGD-GL) · Activity 5769637
18 June 2014 Simplified Stability Test · Administrative Inspection
Physical examination · Sector Eastern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 4892333
15 December 2011 Administrative Inspection
Administrative · Sector Eastern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 4209488
3 September 2010 DAPI Audit · Annual Inspection
Physical examination · Sector Eastern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 3928489
7 April 2009 Drydock Exam
Physical examination · Sector Eastern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 3451530
7 July 2008 Re-Inspection
Physical examination · Sector Eastern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 3260757
24 May 2007 Deficiency Check · Re-Inspection
Physical examination · Sector Eastern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 2939894
1 June 2006 Deficiency Check · COI Inspection
Physical examination · Sector Eastern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 2664967
26 May 2006 Administrative Inspection
Administrative · Sector Eastern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 2659856
14 September 2005 Administrative Inspection
Administrative · Sector Eastern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 2492530
14 September 2004 Hull Examination · Periodic Inspection
Physical examination · MSO BUFFALO · USCG Great Lakes District (CGD-GL) · Activity 2269132
15 August 2003 Annual Inspection
Physical examination · MSO BUFFALO · USCG Great Lakes District (CGD-GL) · Activity 1874292
9 August 2002 COI Inspection · Simplified Stability Test · Hull Examination
Physical examination · MSO BUFFALO · USCG Great Lakes District (CGD-GL) · Activity 1658879
14 September 1989 Administrative
Administrative · MSO BUFFALO · USCG Great Lakes District (CGD-GL) · Activity 1346070
4 May 1989 Hull Examination
Physical examination · MSO BUFFALO · USCG Great Lakes District (CGD-GL) · Activity 1203519
9 June 1988 COI Inspection
Physical examination · MSO BUFFALO · USCG Great Lakes District (CGD-GL) · Activity 1200642
7 July 1987 Re-Inspection
Physical examination · MSO BUFFALO · USCG Great Lakes District (CGD-GL) · Activity 1012933
5 September 1986 Type not recorded
No type recorded · MSO BUFFALO · USCG Great Lakes District (CGD-GL) · Activity 1338514
8 May 1986 Re-Inspection
Physical examination · MSO BUFFALO · USCG Great Lakes District (CGD-GL) · Activity 998344
20 June 1985 Type not recorded
No type recorded · MSO BUFFALO · USCG Great Lakes District (CGD-GL) · Activity 1304323
11 April 1985 Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1290900

Deficiency record · 92

13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 20 August 2026 Resolved
Propulsion machinery must be capable of operating at a constant marine load under such requirements. Port engine overheated while underway due to worn raw water impeller. Repair to the satisfaction of attending Marine Inspector. 46 CFR 182.000
Condition: Damaged By Earlier Event
Action required: 701 - Prior to carriage of passengers/cargo
Due 30 August 2026
Resolved 20 August 2026
Resolution: Received objective evidence of repair.
01 - Certificates & Documentation › 011 - Ships Certificates › USCG Certificate of Documentation (COD)
Issued 17 July 2026 Resolved
Vessel's Certificate of Documentation was found expired. renew COD.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 29 July 2026
01 - Certificates & Documentation › 011 - Ships Certificates › Cargo Ship Safety Radio (including exemption)
Issued 17 July 2026 Resolved
[withheld — contains personal information; the deficiency system, dates, and resolution status are shown above]
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 29 July 2026
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 11 June 2025 Resolved
Life ring and life jackets were not marked with the vessels name. Each life jacket, immersion suit, and ring life buoy must be marked in clearly legible block capital letters with the vessel's name.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 25 July 2025
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 11 June 2025 Resolved
Life ring was missing line. At least one ring life buoy must be fitted with a lifeline. If more than one ring life buoy is carried, at least one must not have a lifeline attached. Each lifeline on a ring life buoy must:(1) Be buoyant;(2) Be of at least 18.3 meters (60 feet) in length;(3) Be non-kinking;(4) Have a diameter of at least 7.9 millimeters (5/16 inch);(5) Have a breaking strength of at least 5 kilo-newtons (1,124 pounds); and(6) Be of a dark color if synthetic, or of a type certified to be resistant to deterioration from ultraviolet light.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 25 July 2025
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 11 June 2025 Resolved
Floating waterlight battery was expired and missing lanyard. A vessel must carry one floating waterlight, unless limited to daytime operation. Each floating waterlight must be attached to the lanyard with a corrosion restant clip. Each ring life buoy with a floating waterlight must have a lanyard of at least 910 millimeters (3 feet) in length, but not more than 1,830 millimeters (6 feet), securing the waterlight around the body of the ring life buoy.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 25 July 2025
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 11 June 2025 Resolved
Stowage of life jackets. Life jackets must be stored in convenient places distributed throughout accommodation spaces. Each child size life jacket must be stowed in a location that is appropriately marked and separated from adult life jackets so the child size life jackets are not mistaken for adult life jackets.
Action required: 701 - Prior to carriage of passengers/cargo
Due 11 June 2025
Resolved 25 July 2025
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 11 June 2025 Resolved
Life jacket donning placard. Placards containing instructions for the donning and use of the life jackets aboard the vessel must be posted in conspicuous places that are regularly accessible and visible to the crew and passengers.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 25 July 2025
11 - Life Saving Appliances › N/A - No Subsystem › Distress flares
Issued 11 June 2025 Resolved
Distress signals were expired. Lakes, bays, and sounds, and rivers routes. A vessel on a lakes, bays, and sounds, or rivers route must carry:(1) Three hand red flare distress signals approved in accordance with § 160.021 in subchapter Q of this chapter, or other standard specified by the Commandant; and(2) Three hand orange smoke distress signals approved in accordance with § 160.037 in subchapter Q of this chapter, or other standard specified by the Commandant.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 25 July 2025
04 - Emergency Systems › N/A - No Subsystem › Functionality of Safety Systems
Issued 11 June 2025 Resolved
Crew training and drill log was not completed. Emergency instructions were not available. Passenger safety orientation has not been completed. Ensure applicable requirements of 46 CFR Part 185 has been reviewed, understood and completed. https://www.ecfr.gov/current/title-46/part-185
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 25 July 2025
09 - Working and Living Conditions › 091 - Living Conditions › Medical Equipment
Issued 11 June 2025 Resolved
First aid kit with required contents was not complete or contained expired items. A vessel must carry either a first-aid kit that meets the requirements in 46 CFR 199.175(b)(10) or a kit with equivalent contents and instructions. For equivalent kits, the contents must be stowed in a suitable, watertight container that is marked “First-Aid Kit”. A first-aid kit must be easily visible and readily available to the crew.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 25 July 2025
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 11 June 2025 Resolved
Vessel had 2 fire buckets. A vessel not required to have a power driven fire pump by § 181.300 must have at least three 9.5 liter (21/2 gallon) buckets, with an attached lanyard satisfactory to the cognizant OCMI, placed so as to be easily available during an emergency. The words “FIRE BUCKET” must be stenciled
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 25 July 2025
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 11 June 2025 Resolved
Portable fire extinguisher must be installed and mounted at the operating station.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 25 July 2025
07 - Fire Safety › N/A - No Subsystem › Fire detection and alarm system
Issued 11 June 2025 Resolved
Fire and heat detection system must be serviced and operable. Fire extinguishing equipment installed on a vessel in excess of the requirements of §§ 181.400 and 181.500 must be designed, constructed, installed, and maintained in accordance with a recognized industry standard acceptable to the Commandant (CG-ENG-4)
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 25 July 2025
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 11 June 2025 Resolved
A section of exhaust was not protected. The part of the exhaust system between the point of cooling water injection and the engine manifold must be water-jacketed or effectively insulated and protected in compliance with §§ 177.405(b) and 177.970 of this chapter. 46 CFR 177.970 Piping, including valves, pipe fittings and flanges, conveying vapor, gas, or liquid, the temperature of which exceeds 65.5 °C (150 °F), must be suitably insulated where necessary to prevent injuries.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 25 July 2025
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 11 June 2025 Resolved
Dead ended electrical wires were found in the wheel house. Each connection to a conductor or terminal part of a conductor must be made within an enclosure and have either:(1) A pressure type connector on each conductor;(2) A solder lug on each conductor;(3) A splice made with a pressure type connector to a flexible lead or conductor; or(4) A splice that is soldered, brazed, or welded to a flexible lead or conductor.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 25 July 2025
18 - Maritime Labour Convention (Not Applicable to PSC Exams conducted in the U.S.) › N/A - No Subsystem › Other (Conditions of employment)
Issued 11 June 2025 Resolved
Drug and Alcohol Program is not in place. A drug and alcohol program must be established by the marine employer in accordance with the requirements of 46 CFR Part 16 and 49 CFR Part 40
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 25 July 2025
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 11 June 2025 Resolved
Electrical distribution bus panel in engine space was not protected. Electrical equipment on a vessel must be installed and maintained to:(a) Provide services necessary for safety under normal and emergency conditions;(b) Protect passengers, crew, other persons, and the vessel from electrical hazards, including fire,caused by or originating in electrical equipment, and electrical shock;(c) Minimize accidental personnel contact with energized parts; and(d) Prevent electrical ignition of flammable vapors.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 25 July 2025
01 - Certificates & Documentation › 012 - Crew Certificates › Certificates for master and officers
Issued 11 June 2025 Resolved
Except as provided by § 15.725, no vessel may be navigated unless it has in its service and onboard the crew complement required by the COI.No vessel subject to inspection under 46 U.S.C. 3301 will be navigated unless it is under the direction and control of an individual who holds an appropriate officer endorsement on their MMC.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 25 July 2025
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 11 June 2025 Resolved
An unauthorized repair was discovered on the port side shell near the waterline in the interior void space. Determine the extent of damage and repair in that area and develop a proper repair proposal.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 25 July 2025
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 2 July 2024 Resolved
Portable fire extinguishers need annual servicing.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 25 July 2025
04 - Emergency Systems › N/A - No Subsystem › Man Overboard Drill (MOB)
Issued 2 July 2024 Resolved
The vessels crew was not present during the inspection. Drills must be conducted in the presence of a CG MI prior to carrying passengers.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 25 July 2025
04 - Emergency Systems › N/A - No Subsystem › Man Overboard Drill (MOB)
Issued 28 June 2023 Resolved
MOB and fire drills need to be conducted prior to carrying passengers.
Condition: Invalid
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 13 October 2023
Resolution: Vessel not currently operating. Moved deficiency to special note.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Scuppers, inlets and discharges
Issued 5 May 2023 Resolved
Threads on aft drain plug through hull fitting are corroded. Renew through hull fitting and ensure watertight integrity.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 9 May 2023
Resolution: Drain plug was cut out and renewed.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Gauges, thermometers, etc
Issued 16 July 2020 Resolved
The stbd main engine's RPM gauge is not functioning. Make repairs or replacements as necessary to prove proper function of an installed RPM guage.
Condition: Damaged By Earlier Event
Action required: 16 - Rectify deficiencies w/in 14 days
Due 30 July 2020
Resolved 23 July 2020
Resolution: RPM gauge reported as repaired and fully functional as per the Captain under the authority of his license.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 16 July 2020 Resolved
The aft engine room bilge alarm is mounted in place with a plastic zip tie. Provide secure and permanent means to fix the bilge alarm in place to ensure proper operation.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 30 July 2020
Resolved 17 July 2020
Resolution: Pics received showing the alarm properly mounted in a permanent fashion.
Electrical › Electrical Distribution System (service) › Circuit Breaker
Issued 8 August 2016 Resolved
As per 46 CFR 183.380(m); For AC systems, circuit breakers must conform to the requirements of UL 489. Current AC breakers meet ABYC standards and are UL 1077 rated which are not acceptable for this installation. Install circuit breakers that meet UL 489.
Condition: Design Flaw
Action required: 705 - Other - as specified
Due 31 August 2016
Resolved 31 August 2016
Resolution: New breakers that meet UL489 installed.
Electrical › Electrical Distribution System (service) › Fuse
Issued 8 August 2016 Resolved
As per 46 CFR 183.380(l); Fuses must be of the cartridge type only and be listed by Underwriters Laboratories (UL) or other independent laboratory recognized by the commandant. Current fuses are not of the cartridge type. Install cartridge type fuses that are UL listed.
Condition: Design Flaw
Action required: 705 - Other - as specified
Due 15 August 2016
Resolved 1 September 2016
Resolution: Current installation accepted with conditions. Added note to MISLE and uploaded OCMI letter dated 29AUG2016.
Engineering › Steering Gear System › Rudder Angle Indicator
Issued 17 May 2016 Resolved
Rudder indicator at operating station not operable. Prove proper operation of rudder indicator to attending CG marine inspector.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 17 June 2016
Resolved 8 June 2016
Resolution: Witnessed proper operation of steering gear and rudder angle indicator.
Fire Fighting › Fixed Fire Detection System › Heat Detectors
Issued 17 May 2016 Resolved
Fire detection system was not installed in machinery space. Install adequate fire detection system and prove proper operation to attending cg marine inspector.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 17 June 2016
Resolved 8 June 2016
Resolution: Witnessed proper operation of fire detection system.
Lifesaving › Lifebuoys › Self-igniting Lights
Issued 3 September 2010 Resolved
Vessel limited to daylight operations only until operating waterlight is provided.
Action required: 705 - Other - as specified
Due 17 September 2010
Resolved 8 September 2010
Resolution: Replaced battery
Lifesaving › Lifejacket/PFD (General) › Quantity
Issued 3 September 2010 Resolved
Vessel is limited to no more than 50 persons until 3 additional adult PFD's are provided.
Action required: 705 - Other - as specified
Due 31 March 2011
Resolved 2 June 2011
Resolution: updated to no more than 47 persons until 6 pfd''s are provided.
Lifesaving › Lifejacket/PFD (General) › Storage
Issued 3 September 2010 Resolved
Properly label pfd stowage with type and quantity.
Action required: 705 - Other - as specified
Due 17 September 2010
Resolved 8 September 2010
Accommodation/Occupational Safety › Occupational Safety › Rubbish/Waste Materials
Issued 3 September 2010 Resolved
Remove rags from engine space and clean up residual oil.
Action required: 705 - Other - as specified
Due 17 September 2010
Resolved 8 September 2010
Fire Fighting › Fire Bucket › Lanyard
Issued 3 September 2010 Resolved
Install lanyard on fire bucket.
Action required: 705 - Other - as specified
Due 17 September 2010
Resolved 8 September 2010
Construction/Loadline › Hull › Hull Plating
Issued 7 April 2009 Resolved
Make proper weld repairs to transom to include removing fuel line and weld hole.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 29 April 2009
Engineering › Shafting/Propeller Arrangements › Propeller (fixed pitch)
Issued 7 April 2009 Resolved
Repair/Replace stbd prop
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 29 April 2009
Engineering › Shafting/Propeller Arrangements › Stern Tube Bearing
Issued 7 April 2009 Resolved
Install new strut bearings
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 29 April 2009
Stability › Unintentional Flooding › General
Issued 7 April 2009 Resolved
Replumb all sea valves to be installed directly on thru-hull fittings.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 29 April 2009
Fire Fighting › Combustible Materials › Insulation
Issued 7 April 2009 Resolved
Remove "sound proofing" on engine hatches. Any installed soundproofing must be iaw 46cfr177.500(c)(4) and meet 46cfr164.009
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 4 May 2009
Stability › Unintentional Flooding › General
Issued 7 April 2009 Resolved
Install/Replace thru-hull fittings (Nylon) with material comparable to hull materials.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 29 April 2009
Engineering › Steering Gear System › Rudder
Issued 7 April 2009 Resolved
Replace bolts in rudder/tiller with grade 5> bolts.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 29 April 2009
Operations/Management › Drug and Alcohol Testing › EAP Training Requirements
Issued 7 July 2008 Resolved
Provide EAP info and required Annual training.
Action required: 705 - Other - as specified
Due 14 July 2008
Resolved 23 July 2008
Accommodation/Occupational Safety › Medical/First Aid › Medicine Chest
Issued 7 July 2008 Resolved
Replace expired items in first aid kit.
Action required: 705 - Other - as specified
Due 14 July 2008
Resolved 23 July 2008
Engineering › Fuel Oil Service System › Filter
Issued 7 July 2008 Resolved
Repair Fuel leak on Port Main engine fuel filter.
Action required: 705 - Other - as specified
Due 14 July 2008
Resolved 23 July 2008
Documentation › Markings/Placards › Garbage Placard
Issued 24 May 2007 Resolved
properly post all required documents, placards and signage within 30 days
Due 24 June 2007
Resolved 26 June 2007
Resolution: All required documents, placards, and signage was posted.
Electrical › Electrical Distribution System (service) › Wiring
Issued 24 May 2007 Resolved
remove all dead end wires from pilot house, properly secure all existing wires within 30 days
Due 24 June 2007
Resolved 26 June 2007
Resolution: All dead end wires were properly secured.
Electrical › Electrical Distribution System (service) › Distribution Panel Bus
Issued 24 May 2007 Resolved
close off openings in electrical boxes at aft end of cabin. Install cover on 110 volt distribution panel within 30 days
Due 24 June 2007
Resolved 26 June 2007
Resolution: Openings were closed off, and covers were installed on 110 volt distribution panel.
Accommodation/Occupational Safety › Medical/First Aid › Medicine Chest
Issued 24 May 2007 Resolved
renew expired items in first aid kit within 30 days
Due 24 June 2007
Resolved 26 June 2007
Resolution: Expired items renewed in first aid kit.
Lifesaving › Lifejacket/PFD (Type I) › Quantity
Issued 24 May 2007 Resolved
replace 2 missing child size life preservers within 30 days. Vessel limited to 4 children on board
Due 24 June 2007
Resolved 26 June 2007
Resolution: 2 child-sized life preservers replaced. Vessel can carry 6 children on board.
Fire Fighting › Portable Dry Chemical Fire Extinguisher › Mounting Bracket
Issued 24 May 2007 Resolved
properly install fire extinguishers on approved brackets within 30 days
Due 24 June 2007
Resolved 26 June 2007
Resolution: installed fire extinguishers on approved brackets properly installed.
Navigation › Collision/Grounding Avoidance › Navigation Lights
Issued 24 May 2007 Resolved
install anchor light within 30 days
Due 24 June 2007
Resolved 26 June 2007
Resolution: Anchor light installed.
Electrical › Electric Supply System (service) › Battery Conductor
Issued 24 May 2007 Resolved
properly secure battery cables at port engine within 30 days
Due 24 June 2007
Resolved 26 June 2007
Resolution: Battery cables secured on port engine.
Engineering › Lubricating Oil Service System › Cooler
Issued 24 May 2007 Resolved
repair broken mounting for starboard main engine oil cooler within 30 days
Due 24 June 2007
Resolved 26 June 2007
Resolution: Broken mounting repaired for stbd main engine oil cooler.
Engineering › Fuel Oil Service System › Piping
Issued 24 May 2007 Resolved
properly secure fuel oil piping at forward end of engine space within 30 days
Due 24 June 2007
Resolved 26 June 2007
Resolution: Fuel oil piping secured properly.
Communications › Public Address System › Loudspeaker
Issued 24 May 2007 Resolved
prove proper operation of public address system within 30 days
Due 24 June 2007
Resolved 26 June 2007
Resolution: PA system properly operating.
Construction/Loadline › Structures › Door
Issued 24 May 2007 Resolved
install coming at aft doorway as per approved plans within 30 days. Vessel is restricted to protected waters until corrected
Due 24 June 2007
Resolved 26 June 2007
Resolution: Coming installed at aft doorway. Vessel no longer restricted to protected waters.
Operations/Management › Drug and Alcohol Testing › Recordkeeping
Issued 24 May 2007 Resolved
provide documentation of compliance with drug/alcohol testing requirements within 30 days
Due 24 June 2007
Resolved 26 June 2007
Resolution: Documentation of compliance w/ drug/alcohol testing provided.
Operations/Management › Drug and Alcohol Testing › Employee Coverage
Issued 1 June 2006 Resolved
Prior to operation provide list of employees enrolled in drug testing program.
Action required: 705 - Other - as specified
Due 1 July 2006
Resolved 22 June 2006
Fire Fighting › Fixed Halon Fire Extinguishing System › Operating Controls
Issued 1 June 2006 Resolved
Prior to operation prove proper operation of engine shutdown for installed halon system.
Action required: 705 - Other - as specified
Due 1 July 2006
Resolved 9 June 2006
Resolution: Vessel is old T and engine compartment is sheated in metal, making this fixed system not required. Owner was advised that if installed it must be serviced and the bottle needs to be installed properly (vertically and not horizontally as it is currently).
Fire Fighting › Fixed Halon Fire Extinguishing System › Operating Controls
Issued 1 June 2006 Resolved
Install Halon system controls and shutdowns to comply with the requirements of 46CFR181.420.
Action required: 705 - Other - as specified
Due 1 July 2006
Resolved 9 June 2006
Resolution: Vessel is old T and engine compartment is sheated in metal, making this fixed system not required. Owner was advised that if installed it must be serviced and the bottle needs to be installed properly (vertically and not horizontally as it is currently).
Lifesaving › Lifebuoys › Serviceable
Issued 1 June 2006 Resolved
Prior to operating provide new ring buoy.
Action required: 705 - Other - as specified
Due 1 July 2006
Resolved 9 June 2006
Lifesaving › Lifebuoys › Self-igniting Lights
Issued 1 June 2006 Resolved
Install corrosion resistant clip on waterlight halyard.
Action required: 705 - Other - as specified
Due 1 July 2006
Resolved 9 June 2006
Lifesaving › Lifejacket/PFD (General) › Quantity
Issued 1 June 2006 Resolved
Vessel is limited to 48 adult persons and 4 persons less than 90 pounds (child size) until correct number of Type I PFD's are provided as per COI. O/O requested deferring to next season prior to operating due to low passenger numbers this season.
Action required: 705 - Other - as specified
Due 1 March 2007
Resolved 24 May 2007
Resolution: Adult life preservers are onboard as per COI. Child size life preservers found deficient, CG- 835 written during inspection on 24 May 07.
Construction/Loadline › Penetrations › Pipe Flange
Issued 1 June 2006 Resolved
Properly cap old generator exhaust and fuel line.
Action required: 705 - Other - as specified
Due 1 July 2006
Resolved 9 June 2006
Electrical › Electrical Distribution System (service) › Switch
Issued 1 June 2006 Resolved
Properly repair port engine shutdown solinoid.
Action required: 705 - Other - as specified
Due 1 July 2006
Resolved 22 June 2006
Navigation › Collision/Grounding Avoidance › Navigation Lights
Issued 1 June 2006 Resolved
Vessel is limited to daytime operations only until port and stbd running lights are replaced.
Action required: 705 - Other - as specified
Due 1 July 2006
Resolved 22 June 2006
Resolution: rcvd fax of receipt for purchase of nav lights.
Fire Fighting › Portable Dry Chemical Fire Extinguisher › Mounting Bracket
Issued 1 June 2006 Resolved
Properly mount dry chemical fire extinguisher with approved bracket.
Action required: 705 - Other - as specified
Due 1 July 2006
Resolved 9 June 2006
Documentation › Manuals/Policy Documentation › Emergency Instructions
Issued 1 June 2006 Resolved
Tailor emergency procedures to vessel.
Action required: 705 - Other - as specified
Due 1 July 2006
Resolved 22 June 2006
Navigation › Piloting/Steering › Marine Charts
Issued 1 June 2006 Resolved
Provide current charts, light list and coast pilot for operating area.
Action required: 705 - Other - as specified
Due 1 July 2006
Resolved 9 June 2006
Operations/Management › Drills/Instruction › Man Overboard Recovery
Issued 1 June 2006 Resolved
Prior to carrying passengers provide means to retrieve helpless person from the water.
Action required: 705 - Other - as specified
Due 1 July 2006
Resolved 22 June 2006
Stability › Watertight Integrity › Coaming
Issued 1 June 2006 Resolved
Install minimum 3" coaming to comply with protected waters route. Vessel is limited to Sodus Bay and Erie Canal.
Action required: 705 - Other - as specified
Due 9 July 2006
Resolved 22 June 2006
Resolution: Owner installed 3" coaming on portside access door. Rear door has no coaming due to already having a reduced vertical height so it cannot remain open while underway as per agreement with BUFMS [name withheld], Chief.
Personnel › Certificates/Documents/Licenses › License, Master
Issued 14 September 2005 Resolved
Provide on board original masters license, stability letter, COI, and COD.
Action required: 701 - Prior to carriage of passengers/cargo
Due 14 September 2005
Resolved 1 June 2006
Operations/Management › Drills/Instruction › Man Overboard Recovery
Issued 14 September 2004 Resolved
Demonstrate emergency drills prior to the satisfaction of the attending CG Marine Inspector prior to commerical operation
Action required: 701 - Prior to carriage of passengers/cargo
Due 14 September 2004
Resolved 1 June 2006
Operations/Management › Bilge/Bilge System Management › Control of Excess Water
Issued 14 September 2004 Resolved
Prove proper operation of bilge monitoring equipment.
Action required: 701 - Prior to carriage of passengers/cargo
Due 14 September 2004
Resolved 1 June 2006
Engineering › Diesel Engine (propulsion-direct drive) › Crankcase
Issued 14 September 2004 Resolved
Prove proper operation of main engine and controlling of vessel while u/w.
Action required: 701 - Prior to carriage of passengers/cargo
Due 14 September 2004
Resolved 1 June 2006
Navigation › Collision/Grounding Avoidance › Navigation Lights
Issued 14 September 2004 Resolved
Paint port and starboard running light shields flat back and remove paint from lens as well as prove proper operation
Action required: 701 - Prior to carriage of passengers/cargo
Due 14 September 2004
Resolved 22 June 2006
Documentation › Logs/Records › Logbook (official)
Issued 14 September 2004 Resolved
Provide logs for inspection attesting to crew training and system maintance.
Action required: 701 - Prior to carriage of passengers/cargo
Due 14 September 2004
Resolved 22 June 2006
Fire Fighting › Fire Bucket › Availability
Issued 14 September 2004 Resolved
Provide 3 fire buckets.
Action required: 701 - Prior to carriage of passengers/cargo
Due 14 September 2004
Resolved 1 June 2006
Fire Fighting › Fixed Gas Fire Extinguishing System › Operating Controls
Issued 14 September 2004 Resolved
Provide documentation attesting to annual servicing of installed fire extinguishers
Action required: 701 - Prior to carriage of passengers/cargo
Due 14 September 2004
Resolved 22 June 2006
Electrical › Electrical Distribution System (service) › Wiring
Issued 14 September 2004 Resolved
Metal wire ties required IWO engine compartment.
Action required: 701 - Prior to carriage of passengers/cargo
Due 14 September 2004
Resolved 1 June 2006
Electrical › Electric Generation Source (service) › Power Requirement
Issued 14 September 2004 Resolved
Provide electrical one line diagram and prove proper operation of gen set prior to commercial operation.
Action required: 701 - Prior to carriage of passengers/cargo
Due 14 September 2004
Resolved 1 June 2006
Resolution: Generator removed from vessel.
Operations/Management › Navigation Safety › Navigation Underway, General
Issued 15 August 2003 Resolved
Provide current chart of the Oswego harbor area. LEGACY COMPONENT DESC: Carriage of Charts and Publications
Condition: Unknown
Due 15 September 2003
Resolved 22 June 2006
Fire Fighting › Portable CO2 Fire Extinguisher › Number
Issued 15 August 2003 Resolved
Provide an additional B-II fire extinguisher.
Condition: Unknown
Due 15 September 2003
Resolved 1 June 2006
Electrical › Electrical Distribution System (service) › Wiring
Issued 15 August 2003 Resolved
Provide a one-line diagram of the electrical system.
Condition: Unknown
Due 15 September 2003
Resolved 14 September 2004
Resolution: Cleared requirement and re-issued under this act.
Electrical › Electric Generation Source (service)
Issued 9 August 2002 Resolved
Electrical generator cannot be used. Prove proper operation of entire AC system prior to operation. LEGACY COMPONENT DESC: Generator
Due 4 October 2002
Resolved 15 August 2003
Electrical › Electric Generation Source (service)
Issued 9 August 2002 Resolved
Provide one line diagram for electrical DC system. LEGACY COMPONENT DESC: Number of Sources
Due 4 October 2002
Resolved 15 August 2003
Engineering › Lubricating Oil Service System
Issued 9 August 2002 Resolved
Replace leaking oil fill cap for straboard engine. LEGACY COMPONENT DESC: Inlet
Due 4 October 2002
Resolved 15 August 2003
Engineering › Diesel Engine (propulsion/auxiliary-electric)
Issued 9 August 2002 Resolved
Prove proper synchronized operation of both tachometers. LEGACY COMPONENT DESC: Overspeed Device
Due 4 October 2002
Resolved 15 August 2003
Accommodation/Occupational Safety › Other Accommodation Spaces
Issued 9 August 2002 Resolved
Remove carpet in maindeckarea. Ensure all flooor coverings comply with 46 CFR 177.410 and 46 CFR 116. LEGACY COMPONENT DESC: Recreation Space
Due 4 October 2002
Resolved 15 August 2003
Accommodation/Occupational Safety
Issued 7 July 1987 Resolved
AFT HAND RAIL TO 01 DECK HAS BROKEN WELD. WILL CALL UPON COMPLETION.
Condition: Unknown
Due 7 July 1987
Resolved 7 July 1987
Electrical
Issued 7 July 1987 Resolved
MAIN ENGINE GAUGES INSTALLED BUT NOT OPERATIONAL. WILL CALL WHEN COMPLETED.
Condition: Unknown
Due 7 July 1987
Resolved 7 July 1987

Casualty record · 1

21 June 2017Routine · role: Involved in a Marine Casualty · serious marine incident, as classified · 1 injured · activity 6204224
Each line is an incident investigation the Coast Guard recorded with this hull among the vessels involved, with the date and the classification the Coast Guard gave it, and the bridge, lock or dam the investigation names where it names one. Involvement is not fault. The investigation narrative is not published. Source: IIR, through 2026.

Recorded names · 1

RIVER TYME (2017). Names as the Coast Guard recorded them in incident records, with the years they appear; some are renames and some are spelling variants.

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.