Records from 1984 to 2007. Most recent: inspection, 25 July 2007.
A report is not offered for this hull: Its record holds only 2 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. Reports.
Inspection history · 93
25 July 2007
COC-MODU Annual
Type not classified · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 3007370
6 July 2007
Administrative Inspection
Administrative · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 2985936
26 September 2006
Type not recorded
No type recorded · Marine Safety Unit Port Arthur · USCG Heartland District (CGD-H) · Activity 2789078
31 July 2006
COC-MODU Renew
Type not classified · Marine Safety Unit Port Arthur · USCG Heartland District (CGD-H) · Activity 2728010
8 November 2005
COC-MODU Annual
Type not classified · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 2530614
19 October 2005
Administrative Inspection
Administrative · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 2517664
29 July 2004
Reflagging & Initial Certification
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 2157755
4 February 2004
Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 2009476
12 January 2004
Re-Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 2002129
24 March 2003
Administrative Inspection
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1762245
20 March 2003
Administrative Inspection
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1760075
23 January 2003
Hull Examination · Re-Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1734750
21 September 2002
Administrative Inspection
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1678444
4 September 2002
Administrative Inspection
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1670629
7 June 2002
Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1671063
26 October 2001
COI Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1410686
22 September 2001
Administrative
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1073586
29 July 2001
Administrative
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1070071
20 May 2001
Administrative
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1063810
16 April 2001
Hull Examination
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1405159
24 February 2001
Administrative
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1059455
6 January 2001
Administrative
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1056817
30 October 2000
Re-Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1465604
20 June 2000
Administrative
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 819576
11 May 2000
Administrative
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 818174
17 March 2000
Administrative
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 818319
14 February 2000
Administrative
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 816174
13 January 2000
Administrative
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1045514
23 November 1999
Administrative
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 810110
25 October 1999
COI Inspection
Physical examination · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1466086
22 September 1999
Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1339470
23 August 1999
Administrative
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1114469
25 July 1999
Administrative
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1104483
17 June 1999
Administrative
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 878750
21 May 1999
Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 100783
3 November 1998
Re-Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1469873
28 July 1998
Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 25005
28 July 1998
Administrative
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 795507
28 April 1998
Hull Examination
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1449047
4 November 1997
COI Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1416586
20 May 1997
Administrative
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1102286
7 March 1997
Administrative
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1096809
10 January 1997
Deficiency Check
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1098296
9 December 1996
Re-Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1392575
6 September 1996
Administrative
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1254632
30 August 1996
Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1419654
14 May 1996
Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1088178
24 April 1996
Hull Examination
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1414620
29 December 1995
Administrative
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1185729
26 December 1995
Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1183817
9 November 1995
Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 884282
9 November 1995
COI Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1357389
11 September 1995
Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 879405
17 July 1995
Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1186571
5 January 1995
Re-Inspection
Physical examination · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1389977
16 March 1994
Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 656028
22 February 1994
Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 72545
8 February 1994
Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1163213
7 February 1994
Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 120166
17 November 1993
COI Inspection
Physical examination · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 849076
17 November 1993
Administrative
Administrative · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 853367
20 September 1993
Administrative
Administrative · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 842332
6 August 1993
Administrative
Administrative · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 844254
19 July 1993
Deficiency Check
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1158662
15 April 1993
Hull Examination · Examination of Repairs
Physical examination · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 829079
30 March 1993
Type not recorded
No type recorded · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1145439
31 October 1992
Re-Inspection
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1137059
29 October 1992
Type not recorded
No type recorded · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 960254
14 September 1992
Type not recorded
No type recorded · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1259933
26 July 1992
Type not recorded
No type recorded · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 183784
8 July 1992
Deficiency Check
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 957626
18 November 1991
COI Inspection · Hull Examination
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1261664
20 September 1991
COI Inspection
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1250019
14 August 1991
Administrative
Administrative · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 932573
11 January 1991
Administrative
Administrative · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1232871
29 November 1990
Type not recorded
No type recorded · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 901458
11 November 1990
Re-Inspection
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 923093
8 August 1990
Administrative
Administrative · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 923567
13 April 1990
Administrative
Administrative · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1233639
8 February 1990
Administrative
Administrative · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1227097
20 September 1989
COI Inspection · Hull Examination
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 905282
18 September 1989
Administrative
Administrative · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1351987
21 March 1989
Administrative
Administrative · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1352788
17 March 1989
Administrative
Administrative · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1032413
14 October 1988
Re-Inspection
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 888018
6 May 1988
Deficiency Check
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1351036
1 March 1988
Administrative
Administrative · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1334518
11 November 1987
Hull Examination
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1018906
17 October 1987
COI Inspection · Deficiency Check
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1018112
5 December 1986
Administrative
Administrative · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1309022
3 December 1986
Administrative
Administrative · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1328682
3 January 1985
Type not recorded
No type recorded · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 978435
7 November 1984
Type not recorded
No type recorded · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1284618
Fire Fighting › Structural - A Class Divisions › Doors
Issued 31 July 2006
Resolved
Class "A" doors in stair tower need adjustment to shut and latch automatically. Repair or adjust to the satisfaction of flag state.
Action required: 705 - Other - as specified
Due 1 September 2006
Resolved 25 July 2007
Accommodation/Occupational Safety › Ventilation › General
Issued 31 July 2006
Resolved
Mud pit room door edges wasted. Repair or replace mud pit doors to the satisfaction of flag state.
Action required: 705 - Other - as specified
Due 1 September 2006
Resolved 25 July 2007
Lifesaving › Lifeboat › Markings
Issued 31 July 2006
Resolved
Lifeboat international orange paint severely weathered. Repair/paint lifeboats to the satisfaction of flag state.
Action required: 705 - Other - as specified
Due 1 September 2006
Resolved 25 July 2007
Engineering › Pressure Vessel › Shell Plate
Issued 8 November 2005
Resolved
Provide proof of satisfactory inspection of all pressure vessels.
Action required: 705 - Other - as specified
Due 1 December 2005
Resolved 18 January 2006
Fire Fighting › Fire Main › Material
Issued 1 November 2005
Resolved
Replace nonmetallic expansion joint on fire pump #1 vertical riser
Due 15 November 2005
Resolved 3 November 2005
Resolution: Item replaced
Construction/Loadline
Issued 16 April 2001
Resolved
CONDUCT LEG TO CAN EXAM (NDE) AND CAN SWIM-BY. SUBMIT COPY OF DIVER'S REPORT AND VIDEO TO THE [name withheld].
Condition: Unknown
Due 16 April 2001
Resolved 16 April 2001
Construction/Loadline
Issued 16 April 2001
Resolved
MAKE MASTER DUMP VALVE AVAILABLE FOR INSPECTION.
Condition: Unknown
Due 16 April 2001
Resolved 16 April 2001
Construction/Loadline
Issued 30 October 2000
Resolved
CROP AND RENEW WASTED AND HOLED HANDRAILS AND GRATINGS THROUGHOUT RIG AS NECESSARY.
Condition: Unknown
Due 18 December 2000
Resolved 19 December 2000
Fire Fighting
Issued 30 October 2000
Resolved
PROVIDE GENERAL ALARM BELL IN SMOKE SHACK.
Condition: Unknown
Due 14 December 2000
Resolved 14 December 2000
Unknown
Issued 30 October 2000
Resolved
CROP AND RENEW WASTED AND HOLED OVERHEAD IN SHALE SHAKERS.
Condition: Unknown
Due 30 October 2000
Resolved 30 October 2000
Electrical
Issued 30 October 2000
Resolved
CONDUCT SEMI-ANNUAL LOAD TEST ON EMERGENCY BATTERIES AND PROPERLY LOG.
Condition: Unknown
Due 18 December 2000
Resolved 19 December 2000
Electrical
Issued 25 October 1999
Resolved
In all three crane cabs remove dead end wires or terminate wires in metal junction box.
Condition: Unknown
Due 4 November 1999
Resolved 4 November 1999
Electrical
Issued 25 October 1999
Resolved
Remove or repair electrical receptacle on drill floor, old BOP hook-up.
Condition: Unknown
Due 4 November 1999
Resolved 4 November 1999
Electrical
Issued 25 October 1999
Resolved
Re-label emergency generator shutdown in emergency generator room.
Condition: Unknown
Due 4 November 1999
Resolved 4 November 1999
Electrical
Issued 25 October 1999
Resolved
ensure proper operation of low lube oil shut down on number 2 generator.
Condition: Unknown
Due 4 November 1999
Resolved 4 November 1999
Unknown
Issued 3 November 1998
Resolved
HYDROSTATICALLY TEST, CONDUCT NDE OR REPLACE AIR RECEIVER THAT SERVICES THEDRILL FLOOR.
Condition: Unknown
Due 3 November 1998
Resolved 3 November 1998
Lifesaving
Issued 3 November 1998
Resolved
CONDUCT 1.1 LIFEBOAT RELEASE GEAR TEST OF BOTH LIFEBOATS OR ALTERNATE TEST SUBJECT TO THE APPROVAL OF THE LOCAL OCMI.
Condition: Unknown
Due 3 November 1998
Resolved 3 November 1998
Fire Fighting
Issued 3 November 1998
Resolved
CROP AND RENEW AS ORIGINAL CO2 PIPING WHERE WASTED IN THE MUD PITS._x001C_ _x001C_ _x001C_ _x001C_
Condition: Unknown
Due 3 November 1998
Resolved 3 November 1998
Construction/Loadline
Issued 28 April 1998
Resolved
CONDUCT NDE OF CRITICAL LEG TO CAN CONNECTIONS. CONDUCT UNDERWATER SWIM-BY_x001C_ON LOWER CANS. SUBMIT COPY OF ALL REPORTS AND DIVERS UNDERWATER VIDEO TO_x001C_ [name withheld].
Condition: Unknown
Due 28 April 1998
Resolved 28 April 1998
Construction/Loadline
Issued 28 April 1998
Resolved
CROP AND RENEW PRE-LOAD TANK COVER GASKET INNER RINGS THROUGHOUT RIG AS NECESSARY.
Condition: Unknown
Due 28 April 1998
Resolved 28 April 1998
Construction/Loadline
Issued 28 April 1998
Resolved
CROP AND RENEW MUD DUMP LINE "T" WHERE DOUBLER IS INSTALLED (VOID #12).
Condition: Unknown
Due 28 April 1998
Resolved 28 April 1998
Construction/Loadline
Issued 28 April 1998
Resolved
DE-SCALE AND INSPECT THROUGH-BULKHEAD PENETRATIONS BETWEEN PRE-LOAD TANK_x001C_ #28S AND DRILL WATER TANK #26S.
Condition: Unknown
Due 28 April 1998
Resolved 28 April 1998
Lifesaving
Issued 4 November 1997
Resolved
REPAIR HULL FRACTURES ON LIFEBOAT NO. 2. REPAIR PORT QUARTER HANDRAIL BRACKET ON LIFEBOAT NO. 1.
Condition: Unknown
Due 4 November 1997
Resolved 4 November 1997
Electrical
Issued 4 November 1997
Resolved
INSTALL SAFETY RELIEF VALVE BETWEEN DISCHARGE AND ISOLATION VALVE ON COLD START COMPRESSOR.
Condition: Unknown
Due 4 November 1997
Resolved 4 November 1997
Lifesaving
Issued 4 November 1997
Resolved
CROP AND RENEW WASTED MUD PIT ROOM DECK PLATING.
Condition: Unknown
Due 4 November 1997
Resolved 4 November 1997
Documentation
Issued 9 December 1996
Resolved
REVISE FIRE CONTROL AND SAFETY PLAN. SUBMIT REVISED PLAN TO COGNIZANT OCMI FOR APPROVAL. INCLUDE REMOVAL OF FIXED FOAM SYSTEM / HELO FUELING STATION AND INCREASE IN LIFERAFT CAPACITY.
Condition: Unknown
Due 9 December 1996
Resolved 9 December 1996
Fire Fighting
Issued 9 December 1996
Resolved
REPLACE BOOTS FOR FIREMAN'S OUTFIT.
Condition: Unknown
Due 9 December 1996
Resolved 9 December 1996
Fire Fighting
Issued 9 December 1996
Resolved
MAKE REPAIRS TO FIREFIGHTING SYSTEMS IN ACCORDANCE WITH TOTAL SAFETY REPORT, DATED 07NOV96.
Condition: Unknown
Due 9 December 1996
Resolved 9 December 1996
Lifesaving
Issued 9 December 1996
Resolved
RENEW LIFEBOAT FALLS PRIOR TO 02MAR97.
Condition: Unknown
Due 9 December 1996
Resolved 9 December 1996
Accommodation/Occupational Safety
Issued 9 December 1996
Resolved
REPAIR/REPLACE BUNK LIGHTS THROUGHOUT RIG.
Condition: Unknown
Due 9 December 1996
Resolved 9 December 1996
Electrical
Issued 9 December 1996
Resolved
REPLACE JACKET WATER BLOCK HEATER ON EMERGENCY GENERATOR.
Condition: Unknown
Due 9 December 1996
Resolved 9 December 1996
Accommodation/Occupational Safety
Issued 9 December 1996
Resolved
PLACE 100 PSI SAFETY RELIEF VALVES ON ALL HOT WATER HEATERS.
Condition: Unknown
Due 9 December 1996
Resolved 9 December 1996
Construction/Loadline
Issued 24 April 1996
Resolved
PERFORM UNDERWATER INSPECTION OF SPUD CANS AND CRITICAL CONNECTIONS TO SATISFACTION OF ATTENDING COAST GUARD INSPECTOR AT NEXT RIG MOVE.
Condition: Unknown
Due 24 April 1996
Resolved 24 April 1996
Deck/Cargo
Issued 9 November 1995
Resolved
PROVIDE UT READINGS OF BULK TANK, SER. #16336, IN ORDER TO DETERMINE AS- BUILT SHELL THICKNESS AND DEPTH OF PITTING. SUBMIT REPAIR PROPOSAL AS NECESSARY PER NVIC 11-92.
Condition: Unknown
Due 9 November 1995
Resolved 9 November 1995
Lifesaving
Issued 9 November 1995
Resolved
REPAIR BROKEN WINDOW ON PORT SIDE OF MUD PIT ROOM.
Condition: Unknown
Due 5 December 1995
Resolved 5 December 1995
Electrical
Issued 9 November 1995
Resolved
PROVE PROPER OPERATION OF LOSS OF PURGE PRESSURE ALARM FOR TOP DRIVE TV MONITOR
Condition: Unknown
Due 27 November 1995
Resolved 27 November 1995
Fire Fighting
Issued 9 November 1995
Resolved
REPAIR LEAKING VALVES AT ALL FIRE STATIONS AS NEEDED.
Condition: Unknown
Due 27 November 1995
Resolved 27 November 1995
Fire Fighting
Issued 9 November 1995
Resolved
RENEW NOZZLE AT FIRE STATION #9.
Condition: Unknown
Due 27 November 1995
Resolved 27 November 1995
Lifesaving
Issued 9 November 1995
Resolved
REPAIR OR REPLACE COMPASS IN #2 LIFEBOAT.
Condition: Unknown
Due 27 November 1995
Resolved 27 November 1995
Accommodation/Occupational Safety
Issued 9 November 1995
Resolved
PROVIDE COPY OF ASME U-1 CERTIFICATE FOR BULK TANK SERIAL #16336.
Condition: Unknown
Due 27 November 1995
Resolved 27 November 1995
Lifesaving
Issued 9 November 1995
Resolved
MAKE BOTH MUD PIT ROOM DOORS CLOSE GAS TIGHT.
Condition: Unknown
Due 5 December 1995
Resolved 5 December 1995
Fire Fighting
Issued 9 November 1995
Resolved
RENEW FIRE MAIN EXTENSION HOSE BELOW CANTILEVER.
Condition: Unknown
Due 27 November 1995
Resolved 27 November 1995
Documentation
Issued 17 November 1993
Resolved
PROVIDE UPDATED LOADLINE CERTIFICATE AND VERIFY HULL MARKINGS.
Condition: Unknown
Due 23 November 1993
Resolved 14 December 1993
Lifesaving
Issued 17 November 1993
Resolved
CONDUCT FIRE AND BOAT DRILL IN THE PRESENCE OF COAST GUARD MARINE INSPECTOR._x001C_
Condition: Unknown
Due 23 November 1993
Resolved 14 December 1993
Accommodation/Occupational Safety
Issued 17 November 1993
Resolved
CONDUCT INTERNAL EXAM DRY BULK TANKS
Condition: Unknown
Due 17 November 1993
Resolved 17 November 1993
Construction/Loadline
Issued 15 April 1993
Resolved
CROP AND RENEW BOTTOM PLATING BETWEEN FRAMES 4 AND 5 IN WAY OF THE #3 PRELOAD TANK INBOARD SIDE AT THE SPUD WELL.
Condition: Unknown
Due 15 April 1993
Resolved 15 April 1993
Construction/Loadline
Issued 15 April 1993
Resolved
REPLACE VERTICAL LADDERS ON PORT AND STBD SIDES OF HULL.
Condition: Unknown
Due 15 April 1993
Resolved 15 April 1993
Lifesaving
Issued 31 October 1992
Resolved
REPLACE OUT OF DATE WATER BAGS ONBOARD PORT AND STBD CAPSULES WITH IN DATE APPROVED WATER BAGS AND PROVIDE OIM STATEMENT OF COMPLIANCE TO [name withheld].
Condition: Unknown
Due 31 October 1992
Resolved 31 October 1992
Documentation
Issued 31 October 1992
Resolved
REVISE OPERATIONS MANUAL TO ACCOUNT FOR NEW TOP DRIVE INSTALLATION AND DERRICK MODIFICATION.
Condition: Unknown
Due 31 October 1992
Resolved 31 October 1992
Documentation
Issued 31 October 1992
Resolved
SUBMIT PLANS AND CALCULATIONS ON VARCO TOP DRIVE INSTALLATION AND DERRICK MODIFICATION FOR APROVAL TO [name withheld].
Condition: Unknown
Due 31 October 1992
Resolved 31 October 1992
Documentation
Issued 18 November 1991
Resolved
PROVIDE COPY OF SPECIAL EXAM IN LIEU OF DRYDOCKING INSPECTION REPORT.
Condition: Unknown
Due 18 November 1991
Resolved 18 November 1991
Documentation
Issued 18 November 1991
Resolved
PROVIDE UP-TO-DATE COPY OF FIRE CONTROL PLAN.
Condition: Unknown
Due 18 November 1991
Resolved 18 November 1991
Documentation
Issued 18 November 1991
Resolved
PROVIDE COPY OF NDT REPORT.
Condition: Unknown
Due 18 November 1991
Resolved 18 November 1991
Accommodation/Occupational Safety
Issued 29 November 1990
Resolved
HYDROSTATICALLY TEST LIFEBOAT AIR CYLINDERS AND SCBA CYLINDERS IAW 49 CFR 173.34 OR PROVE COMPLIANE WITH 49 CFR 173.34 PREVIOUS TESTING.
Condition: Unknown
Due 29 November 1990
Resolved 29 November 1990
Navigation
Issued 11 November 1990
Resolved
INSTALL EXPLOSION PROOF GENERAL BUZZER FOR MUD PIT ROOM.
Condition: Unknown
Due 11 November 1990
Resolved 11 November 1990
Electrical
Issued 11 November 1990
Resolved
SHOW PROPER OPREATION OF #4 GENERATOR REVERSE POWER RELAY
Condition: Unknown
Due 11 November 1990
Resolved 11 November 1990
Accommodation/Occupational Safety
Issued 11 November 1990
Resolved
SHOW PROPER OPERATION OF MARINE SANITIATION SYSTEM.
Condition: Unknown
Due 11 November 1990
Resolved 11 November 1990
Fire Fighting
Issued 11 November 1990
Resolved
REPAIR/REPLACE THE OXYGEN & EXPLOSIVE GAS METERS FOR BOTH FIREMANS OUTFITS.
Condition: Unknown
Due 11 November 1990
Resolved 11 November 1990
Construction/Loadline
Issued 11 November 1990
Resolved
MAKE BOTH DOORS TO MUD PIT ROOM GAS TIGHT.
Condition: Unknown
Due 11 November 1990
Resolved 11 November 1990
Fire Fighting
Issued 11 November 1990
Resolved
SHOW PROPER OPERATION OF #2 FIRE PUMP RELIEF VALVE.
Condition: Unknown
Due 11 November 1990
Resolved 11 November 1990
Engineering
Issued 11 November 1990
Resolved
REPAIR TEST AND PROVE PROPER OPERATION OF OILY WATER SEPERATOR OR REMOVE FROM THE VESSEL. CURRENT IOPP CERTIFICATE EXEMPTION REQUIRES OILY WASTES TOBE MAINTAINED ONBOARD AND TRANSPORTED TO RECEPTION FACILITIES. THIS EXEMPTION DOES NOT APPLY TO VESSELS EQUIPPED WITH TO VESSELS EQUIPPED WITH
Condition: Unknown
Due 11 November 1990
Resolved 11 November 1990
Unknown
Issued 11 November 1990
Resolved
SHOW PROPER OPERATION OF #4 GENERATOR REVERSE POWER RELAY.
Condition: Unknown
Due 11 November 1990
Resolved 11 November 1990
Lifesaving
Issued 20 September 1989
Resolved
HAVE VESSELS LIFEBOAT AIR BOTTLES, SELF CONTAINED BREATHING APPARATUS AND FIXED CO2 CYLINDERS HYDROSTATICALLY TESTED OR PROVE TESTING WAS DONE IN ACCORDANCE WITH 46 CFR 147.04-1(A)(4) AND 49 CFR 173.34
Condition: Unknown
Due 20 September 1989
Resolved 20 September 1989
Lifesaving
Issued 20 September 1989
Resolved
PROVIDE (2) TWO 12') TWELVE FOOT FIRE FIGHTING APPLICATORS FOR THE HELO DECK.
Condition: Unknown
Due 20 September 1989
Resolved 20 September 1989
Lifesaving
Issued 20 September 1989
Resolved
PROIVDE FOAM ANALYSIS CERTIFICATES.
Condition: Unknown
Due 20 September 1989
Resolved 20 September 1989
Electrical
Issued 14 October 1988
Resolved
REPLACE DAMAGED RED GLOBE LIGHT OVER DRILLER'S CONSOLE FOR LOSS OF MUD PIT ROOM VENTILATION.
Condition: Unknown
Due 14 October 1988
Resolved 14 October 1988
Lifesaving
Issued 14 October 1988
Resolved
PERFORM FIVE YEAR HYDROSTATIC TEST OF BREATHING AIR SYSTEM BOTTLES IN BOTH LIFEBOATS.
Condition: Unknown
Due 14 October 1988
Resolved 14 October 1988
Lifesaving
Issued 14 October 1988
Resolved
RENEW BOTH LIFEBOAT FALLS.
Condition: Unknown
Due 14 October 1988
Resolved 14 October 1988
Lifesaving
Issued 14 October 1988
Resolved
RENEW BOTH DAVIT LAUNCHED LIFERAFT FALLS.
Condition: Unknown
Due 14 October 1988
Resolved 14 October 1988
Electrical
Issued 14 October 1988
Resolved
REPAIR AND TEST MAIN CIRCUIT BREAKER FOR POWER VENTILATION AND FUEL OIL TRANSFER PUMP SHUTDOWN. AT SAME TIME TEST FIXED CO2 SYSTEM THEM DELAY AND ENSURE MINIMUM DELAY OF 20 SECONDS.
Condition: Unknown
Due 14 October 1988
Resolved 14 October 1988
Electrical
Issued 14 October 1988
Resolved
PROVE PROPER OPERATION ON LOW LUBE OIL PRESSURE SHUTDOWN FOR EMERGENCY DIESEL GENERATOR.
Condition: Unknown
Due 14 October 1988
Resolved 14 October 1988
Deck/Cargo
Issued 14 October 1988
Resolved
PROVE PROPER OPERATION OF COMBUSTIBLE GAS SENSOR IN SHALE SHAKER AREA.
Condition: Unknown
Due 14 October 1988
Resolved 14 October 1988
Lifesaving
Issued 17 October 1987
Resolved
PROVIDE DAVIT LAUNCHED INFLATABLE LIFERAFTS WITH AGGREGATE CAPACITY OF AT LEAST 78 CURRENT IN ANNUAL AND FIVE YEAR SERVICING IN ACCORDANCE WITH 46 CFR 108.505 AND 46 CFR 160.051-6. RAFTS ONBOARD ARE OVERDUE FOR SERVICING.
Condition: Unknown
Due 17 October 1987
Resolved 17 October 1987
Unknown
Issued 17 October 1987
Resolved
PROVE PROPER OPERATION OF H2S AND GAS DETECTION SYSTEM. FRESH SPAN GAS NOTAVAILABLE AT TIME OF INSPECTION.
Condition: Unknown
Due 17 October 1987
Resolved 17 October 1987
Engineering
Issued 17 October 1987
Resolved
PROVE PROPER OPERATION OF OILY WATER SEPARATOR. O.W.S. IS NOT REQUIRED UNDER VESSEL'S INTERNATIONAL OIL POLLUTION PREVENTION CERTIFICATE. OILY WATER SEPARATOR IS FILLED WITH PRESERVATIVE SOLUTION FROM RIG BEING STACK- ED.
Condition: Unknown
Due 17 October 1987
Resolved 17 October 1987
Unknown
Issued 17 October 1987
Resolved
CONDUCT TESTS REQUIRED BY 46 CFR 64.77 FOR TWO PORTABLE MARINE TANKS USED TO STORE HELICOPTER FUEL. MARINE INSPECTOR NEED NOT WITNESS TESTING. LOG RESULTS IN VESSEL LOG.
Condition: Unknown
Due 17 October 1987
Resolved 17 October 1987
Deck/Cargo
Issued 17 October 1987
Resolved
PROVIDE STANDARD OIL DISCHARGE CONNECTION IN ACCORDANCE WITH 33 CFR 155.430 CONNECTION IS MISSING.
Condition: Unknown
Due 17 October 1987
Resolved 17 October 1987
Lifesaving
Issued 17 October 1987
Resolved
PROVIDE CURRENT LIGHTS FOR 65 PERSONAL FLOATATION DEVICES IN ACCORDANCE WITH 46 CFR 108.514(E). 65 OF THE 105 PFD'S ONBOARD HAVE EXPIRES CYALUME LIGHTS.
Condition: Unknown
Due 17 October 1987
Resolved 17 October 1987
Lifesaving
Issued 17 October 1987
Resolved
PROVIDE CURRENT PRIMERS FOR KILGORE LINE THROWING GUN. PRIMERS ONBOARD ARE EXPIRED.
Condition: Unknown
Due 17 October 1987
Resolved 17 October 1987
Lifesaving
Issued 17 October 1987
Resolved
PROVIDE CURRENT PROVISIONS (108 LBS. EA) WATER (162 QTS EA) AND HAND RED PARACHUTE FLARES (12 EA.) AND ONE JACKNIFE (ALL C.G. APPROVED) FOR EACH SURVIVAL CAPSULE. PROVISIONS, WATER, AND FLARES ARE EXPIRED. JACKNIVES ARE MISSING.
Condition: Unknown
Due 17 October 1987
Resolved 17 October 1987
Construction/Loadline
Issued 3 January 1985
Resolved
MAKE WATERTIGHT THE ELECTRICAL WIRING STUFFING TUBE IN THE (PORT) LONGITUDINAL BULKHEAD JUST ABOVE AND AFT OF THE WATERTIGHT DOOR LEADING FROM/TO THE ENGINEROOM TO/FROM THE MACHINE SHOP.
Condition: Unknown
Due 3 January 1985
Resolved 3 January 1985
Lifesaving
Issued 3 January 1985
Resolved
WEIGHT TEST DAVIT LAUNCHED LIFE RAFTS DAVITS
Condition: Unknown
Due 3 January 1985
Resolved 3 January 1985
Fire Fighting
Issued 3 January 1985
Resolved
MAKE WATERPROOF SET OF OPERATING INSTRUCTIONS FOR THE HELO TANK/FIRE MONITOR SYSTEM.
Condition: Unknown
Due 3 January 1985
Resolved 3 January 1985
Unknown
Issued 3 January 1985
Resolved
PROVIDE USCG APPROVED OPERATING MANUAL
Condition: Unknown
Due 3 January 1985
Resolved 3 January 1985
Lifesaving
Issued 3 January 1985
Resolved
WEIGHT TEST PORT & STARBOARD SURVIVAL CAPSULES AND TEST DISENGAGING APPARATUS
Condition: Unknown
Due 3 January 1985
Resolved 3 January 1985
Lifesaving
Issued 3 January 1985
Resolved
PROVIDE 24 PUONDS OF HARD BREAD FOR STARBOARD SURVIVAL CAPSULE
Condition: Unknown
Due 3 January 1985
Resolved 3 January 1985
Engineering
Issued 3 January 1985
Resolved
INSTALL SELF CLOSING VALVES IN THE SIGHT GLASSES FOR THE EMERGENCY GENERATOR FUEL TANK AND THE MAIN DIESEL ENGINES FUEL OIL DAY TANK.
Condition: Unknown
Due 3 January 1985
Resolved 3 January 1985
Engineering
Issued 7 November 1984
Resolved
INSTALL SELF CLOSING VALVES IN THE SIGHT GLASSES FOR THE EMERGENCY GENERATOR FUEL TANK AND THE MAIN DIESEL ENGINES FUEL OIL DAY TANK.
Condition: Unknown
Due 7 November 1984
Resolved 7 November 1984
Lifesaving
Issued 7 November 1984
Resolved
CONDUCT A WEIGHT TEST OF BOTH THE PORT AND STARBOARD DAVIT LAUNCHED LIFE RAFTS DAVITS.
Condition: Unknown
Due 7 November 1984
Resolved 7 November 1984
Construction/Loadline
Issued 7 November 1984
Resolved
MAKE WATERTIGHT THE ELECTRICAL WIRING STUFFING TUBE IN THE (PORT) LONGITUDINAL BULKHEAD JUST ABOVE AND AFT OF THE WATERTIGHT DOOR LEADING FROM/TO THE ENGINE ROOM TO/FROM THE MACHINE SHOP.
Condition: Unknown
Due 7 November 1984
Resolved 7 November 1984
Fire Fighting
Issued 7 November 1984
Resolved
MAKE A WATERPROOF SET OF OPERATING INSTRUCTIONS FOR THE HELO FOAM TANK/FIREMONITOR SYSTEM, POST SAME AT THE HELO FOAM TANK AND LABEL THE SYSTEM'S VALVES (TO CORRESPOND WITH THE OPERATING INSTRUCTIONS) FOR LINING THE SYSTEM UP. THE LETTERING SHOULD BE AT LEAST 1/4" IN HEIGHT.
Condition: Unknown
Due 7 November 1984
Resolved 7 November 1984
Unknown
Issued 7 November 1984
Resolved
PROVIDE ON BOARD THE USCG APPROVED OPERATING MANUAL (BEARING USCG APPROVAL DATE 25 NOV 1982) AS REFERENCED IN [name withheld], MASS STABILITY LETTER OF 25 MARCH 1983.
Condition: Unknown
Due 7 November 1984
Resolved 7 November 1984
Lifesaving
Issued 7 November 1984
Resolved
PROVIDE 24.2 POUNDS OF HARD BREAD OR ITS APPROVED EQUIVALENT FOR THE STARBOARD SURVIVAL CAPSULE: SEE 46CFR 94.20-15(BB)
Condition: Unknown
Due 7 November 1984
Resolved 7 November 1984
Lifesaving
Issued 7 November 1984
Resolved
CONDUCT A WEIGHT TEST OF THE PORT AND STARBOARD SURVIVAL CAPSULES AND TEST THE CAPULES' DISENGAGING APPARATUS.
Condition: Unknown
Due 7 November 1984
Resolved 7 November 1984