FMS LIBERTY is a 1983 offshore supply vessel. The Coast Guard has recorded 67 inspections since 1983, most recently in July 2017, along with 57 deficiencies — 5 with no resolution recorded — and 1 operational control.

Records from 1983 to 2017. Most recent: inspection, 5 July 2017.

Built
1983
Last inspected
5 July 2017
Documentation
Not in the documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

8424599 View on MarineTraffic leaves Maury; a third-party site, nothing from it is stored here
WDG5057
Flag
UNITED STATES
367028410, 367341960, 367491440, 367542850 (licence lapsed)
Maury page id
psix-54872

Inspections, by type

…with no type recorded21
Years with a record 31 calendar years (1983–2017)
The 67 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

This record may be incomplete: the most recent inspection recorded for this vessel was 9 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Offshore class in Maury's sources begin in 1978.

Documentation record

Tonnage as PSIX records it295 - Regulatory (Subpart C or D), Gross Ton
1057 - Convention (Subpart B), Gross Ton
200 - Regulatory (Subpart C or D), Net Ton
330 - Convention (Subpart B), Net Ton
1164 - Dead Weight, Ton
864 - Displacement, Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.

Radio station licence

WDG5057MMSI 367542850 · expired · compulsorily equipped · granted 18 August 2012, cancelled 22 October 2022
WDF8105MMSI 367491440 · expired · compulsorily equipped · granted 20 May 2011, cancelled 24 July 2021 · licensed under a name not among this hull’s recorded names (not shown)
WDE3636MMSI 367341960 · expired · compulsorily equipped · granted 8 March 2008, cancelled 12 May 2018 · licensed under a name not among this hull’s recorded names (not shown)
WRB7548MMSI 367028410 · expired · compulsorily equipped · granted 10 January 2008, cancelled 24 March 2018 · licensed under a name not among this hull’s recorded names (not shown)
FCC Universal Licensing System ship-station file of 6 September 2026, matched to this hull on its US Official Number. Status and dates are the file’s own. The licensee is not read from the file and is not shown. A lapsed licence’s MMSI is still the number the vessel transmitted under while it was valid.

Inspection history · 67

5 July 2017 Administrative Inspection
Administrative · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 6198806
24 October 2016 Annual Inspection
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 6028633
28 July 2015 Administrative Inspection · Internal Structural Exam · Periodic Inspection · Hull Examination
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 5199005
12 August 2014 Annual Inspection · Administrative Inspection
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 4977696
10 June 2014 Type not recorded
No type recorded · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 4885271
27 May 2014 Type not recorded
No type recorded · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 4884924
29 June 2012 MTSA Verification · Administrative Inspection · Drydock Exam · COI Inspection
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 4361267
16 December 2011 Administrative Inspection · Annual Inspection
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 4209383
7 April 2009 Type not recorded
No type recorded · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 3444800
21 August 2008 MTSA Verification · Annual Inspection
Physical examination · Marine Safety Unit Port Arthur · USCG Heartland District (CGD-H) · Activity 3295787
24 June 2008 Administrative Inspection
Administrative · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 3246626
14 September 2007 Type not recorded
No type recorded · Marine Safety Unit Lake Charles · USCG Heartland District (CGD-H) · Activity 3057832
8 June 2007 Cargo Tank Internal · Internal Structural Exam · Hull Examination
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 2977579
22 September 2006 Deficiency Check · Re-Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 2784833
31 July 2006 Type not recorded
No type recorded · Marine Safety Unit Galveston · USCG Heartland District (CGD-H) · Activity 2731368
30 July 2006 Type not recorded
No type recorded · Marine Safety Unit Galveston · USCG Heartland District (CGD-H) · Activity 2731276
20 October 2005 Type not recorded
No type recorded · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 2518544
17 October 2005 Type not recorded
No type recorded · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 2516366
26 September 2005 Security Plan Amendment Review - VSP
Administrative · Marine Safety Center (MSC) · Activity 2501569
28 June 2005 Re-Inspection · Hull Examination
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 2406640
20 March 2005 Administrative Inspection
Administrative · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 2316418
17 February 2005 Type not recorded
No type recorded · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 2298444
16 February 2005 Security Plan Amendment Review - VSP
Administrative · Marine Safety Center (MSC) · Activity 2293924
18 October 2004 Re-Inspection · MTSA Verification
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 2223049
3 November 2003 Security Plan Review - VSP
Administrative · Marine Safety Center (MSC) · Activity 1979480
21 October 2003 Re-Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 1933257
23 August 2002 COI Inspection · Hull Examination
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 1665268
26 February 2002 Deficiency Check
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 1490180
11 January 2002 COI Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 1477739
13 June 2001 Deficiency Check
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1066166
4 April 2001 Re-Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1471604
14 August 2000 Hull Examination
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1433719
24 March 2000 Type not recorded
No type recorded · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 767025
23 March 2000 Type not recorded
No type recorded · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 208514
13 January 2000 COI Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1466095
29 November 1999 Type not recorded
No type recorded · MSO Mobile · USCG Heartland District (CGD-H) · Activity 58713
11 January 1999 Re-Inspection
Physical examination · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 1432048
30 January 1998 Deficiency Check
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1028518
16 January 1998 Hull Examination · COI Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1441331
1 October 1996 Administrative
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 836811
12 December 1994 Administrative
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 833837
19 July 1994 COI Inspection
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1380013
12 April 1994 Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 665728
12 April 1994 Deficiency Check
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 857797
8 April 1994 Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 50769
8 April 1994 Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 65934
8 April 1994 Damage Survey
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1167477
9 September 1993 Re-Inspection
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1359641
21 December 1992 Administrative
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1134814
15 October 1992 Hull Examination
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1436712
1 September 1992 Deficiency Check
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 957924
28 July 1992 COI Inspection
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 944256
30 October 1991 Administrative
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1252641
26 September 1991 Re-Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 938409
29 October 1990 Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1213486
30 July 1990 Hull Examination · COI Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1237342
22 August 1989 Re-Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1036795
1 November 1988 Administrative
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 890793
9 August 1988 COI Inspection · MARPOL Annex II Examination
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1037648
30 October 1987 Hull Examination
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1325740
2 April 1987 Re-Inspection
Physical examination · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1026651
3 April 1986 Credit Drydock · COI Inspection
Physical examination · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1003208
21 March 1985 Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1291811
14 September 1984 Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1282056
2 April 1984 Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1280317
22 March 1984 Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 973093
24 March 1983 Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 968030

Deficiency record · 57

Documentation › Logs/Records › Operational Procedures for Engines or Equipment
Issued 24 October 2016 No resolution recorded
Need to complete annual automation testing as per new & approved automation testing procedures & provide procedures for inspection. 46CFR61.40
Condition: Invalid
Action required: 705 - Other - as specified
Personnel › Manning/Qualifications › Minimum Safe Manning
Issued 24 October 2016 No resolution recorded
Reduce total persons allowed from 22 to 21, due to limited berthing. COI to be amended. 46CFR92.20-20(c)(1)
Condition: Invalid
Action required: 705 - Other - as specified
Electrical › Electrical Distribution System (service) › Wiring
Issued 24 October 2016 No resolution recorded
Replace wire nuts on STBD main & mud pump IAW subch. J. 46CFR111.60-17(b)
Condition: Improper Installation
Action required: 705 - Other - as specified
Lifesaving › Embarkation Appliances/Stations › Designated Location
Issued 24 October 2016 No resolution recorded
Embarkation lighting for liferafts, when not under power need to operate. 46CFR94.50-15
Condition: Design Flaw
Action required: 705 - Other - as specified
Engineering › Diesel Engine (propulsion/auxiliary-electric) › Emergency shutdown
Issued 24 October 2016 No resolution recorded
Bow thruster remote stop & STBD main remote stop not working. Need to be re-inspected & tested to the satisfaction of attending marine inspector. 46CFR61.20-3
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Construction/Loadline › Structures › Scupper
Issued 28 July 2015 Resolved
vessel needs to be recalculated on deck area for proper freeing port locations. Be completed during next dry dock
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 2 July 2017
Resolved 14 January 2016
Documentation › Safety/Response Plans/Programs › Fire Control Plans
Issued 28 July 2015 Resolved
stamped and corrected
Condition: Invalid
Action required: 17 - Rectify deficiencies prior to departure
Due 30 November 2015
Resolved 14 January 2016
Communications › Radio Communications › VHF Radiotelephone
Issued 28 July 2015 Resolved
Place Plcard with call sign on Bridge next to VHF radios
Condition: Improper Installation
Action required: 17 - Rectify deficiencies prior to departure
Due 30 November 2015
Resolved 14 January 2016
Engineering › Shafting/Propeller Arrangements › Propeller Shaft
Issued 28 July 2015 Resolved
Repair Shaft Tech and rudder angle indictor
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 30 November 2015
Resolved 14 January 2016
Engineering › Diesel Engine (propulsion-direct drive) › Emergency shutdown
Issued 28 July 2015 Resolved
starboard engine overspeed needs to be repaired and retested
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 30 November 2015
Resolved 14 January 2016
Engineering › Steering Gear System › Rudder Angle Indicator
Issued 28 July 2015 Resolved
fix rudder angle indictor in aft station and engine room
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 30 November 2015
Resolved 14 January 2016
Lifesaving › Lifebuoys › Buoyant Lifeline
Issued 28 July 2015 Resolved
replace life line on port bridge ring buoy
Condition: Damaged By Earlier Event
Action required: 17 - Rectify deficiencies prior to departure
Due 30 November 2015
Resolved 14 January 2016
Lifesaving › Hand Flares › Expired
Issued 22 September 2006 Resolved
PROVIDE REQUIRED NUMBER (12) OF ALL DISTRESS SIGNALS PRIOR TO SAILING.
Action required: 17 - Rectify deficiencies prior to departure
Due 22 October 2006
Resolved 22 September 2006
Resolution: PROVIDED FLARES
Personnel › Training › Search and Rescue
Issued 22 September 2006 Resolved
PROVIDE AND INSPECT TWO RESCUE HARNESSES PRIOR TO SAILING.
Action required: 17 - Rectify deficiencies prior to departure
Due 22 October 2006
Resolved 22 September 2006
Resolution: RPOVIDED TWO HARNESS AND CREATED LIG AND INSPECTED SAME.
Accommodation/Occupational Safety › Medical/First Aid › Medicine Chest
Issued 22 September 2006 Resolved
RESTOCK ALL FIRST AID KITS.
Action required: 17 - Rectify deficiencies prior to departure
Due 22 October 2006
Resolved 22 September 2006
Resolution: PROVIDED STOCKED FIRST AID KITS.
Accommodation/Occupational Safety › Occupational Safety › Deck Rail
Issued 22 September 2006 Resolved
DEMONSTRATE PROPER HEIGHT OF RESCUE ZONE OPENING HAND RAILS PRIOR TO SAILING.
Condition: Damaged By Earlier Event
Action required: 17 - Rectify deficiencies prior to departure
Due 22 October 2006
Resolved 22 September 2006
Resolution: HEIGHT CORRECTED AT SIDE BULLWORK OPENINGS.
Lifesaving › Buoyant Apparatus › Lifeline
Issued 22 September 2006 Resolved
ATTACH CORRECTLY ALL LIGHTS AND LIFE LINES TO ALL LIFE RINGS PRIOR TO SAILING.
Action required: 17 - Rectify deficiencies prior to departure
Due 22 October 2006
Resolved 22 September 2006
Resolution: ATTACHED ALL LIFE LINES AND LIGHTS AROUND BODY OF LIFE RING.
Engineering › Diesel Engine (propulsion-direct drive) › Piping (exhaust)
Issued 22 September 2006 Resolved
INSTALL EXHAUST BLANKET ON CENTER GENERATOR PRIOR TO SAILING.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 22 October 2006
Resolved 22 September 2006
Resolution: INSTALLED MISSING EXHAUST BLANKET OVER EXHAUST PIPING IN ENGINE ROOM.
Electrical › Lighting (service) › Lighting Fixture
Issued 22 September 2006 Resolved
RENEW ALL LIGHT FIXTURE COVERS IN ENGINE ROOM AS MARKED (3).
Action required: 705 - Other - as specified
Due 22 October 2006
Resolved 22 September 2006
Resolution: RENEWED ALL LIGHT FIXTURE COVERS AS MARKED.
Communications › Internal Communications System › Voice Tube
Issued 28 June 2005 Resolved
Provide a PA system IAW 46 CFR Subpart 113.50
Due 6 August 2005
Resolved 22 July 2005
Resolution: Installation complies.
Documentation › Safety Management System › Conformity Maintenance Procedures
Issued 18 October 2004 Resolved
Perform Automation tests and provide results to the attending Marine Inspector.
Action required: 705 - Other - as specified
Due 18 November 2004
Resolved 26 October 2004
Fire Fighting › Miscellaneous Items
Issued 22 October 2003 Resolved
Install fixed fire extinguishing system for the paint locker IAW 46 CFR 95.15-56. LEGACY COMPONENT DESC: Paint/Flammable Liquid Lockers
Action required: 705 - Other - as specified
Due 22 November 2003
Resolved 21 November 2003
Construction/Loadline › Structures › Transverse Bulkhead
Issued 22 October 2003 Resolved
Make port and stbd tonnage hatches watertight.
Action required: 17 - Rectify deficiencies prior to departure
Due 22 November 2003
Resolved 24 October 2003
Lifesaving › Inflatable Liferafts › Capacity
Issued 22 October 2003 Resolved
Provide 3 inflatable liferafts with hydrostatic releases and instruction placards.
Action required: 17 - Rectify deficiencies prior to departure
Due 22 November 2003
Resolved 23 October 2003
Construction/Loadline › Structures › Door
Issued 22 October 2003 Resolved
Make repairs to port engine room escape hatch.
Action required: 17 - Rectify deficiencies prior to departure
Due 22 November 2003
Resolved 23 October 2003
Lifesaving › Lifebuoys › Buoyant Lifeline
Issued 22 October 2003 Resolved
Renew port main deck and aft main deck lifebuoy lines.
Action required: 705 - Other - as specified
Due 22 November 2003
Resolved 22 October 2003
Communications › Alarms/Indicators › Bilge Alarm
Issued 22 October 2003 Resolved
Make repairs to passageway bilge alarm sensor.
Action required: 17 - Rectify deficiencies prior to departure
Due 22 November 2003
Resolved 22 October 2003
Electrical › Electric Generation Source (emergency)
Issued 22 October 2003 Resolved
Provide vent louver for radio back-up batteries under pilot house console. LEGACY COMPONENT DESC: Batteries
Action required: 705 - Other - as specified
Due 22 November 2003
Resolved 22 October 2003
Navigation › Emergency Steering
Issued 22 October 2003 Resolved
Provide emergency steering instructions for pilot house. LEGACY COMPONENT DESC: Steering Instructions
Action required: 705 - Other - as specified
Due 22 November 2003
Resolved 10 November 2003
Engineering › Fuel Oil Service System › Filter
Issued 22 October 2003 Resolved
Provide flame shield for port main engine fuel filter bowl.
Action required: 705 - Other - as specified
Due 22 November 2003
Resolved 22 October 2003
Engineering › Diesel Engine (auxiliary)
Issued 22 October 2003 Resolved
Renew flexible hoses as marked on liquid mud pump engine. LEGACY COMPONENT DESC: Flexible Hoses
Action required: 705 - Other - as specified
Due 22 November 2003
Resolved 24 October 2003
Fire Fighting › Fire Main › Condition
Issued 23 August 2002 Resolved
Provide pressure gauge for Fire main at pilot house.
Condition: Improper Installation
Action required: 17 - Rectify deficiencies prior to departure
Due 23 August 2002
Resolved 23 August 2002
Fire Fighting › Portable CO2 Fire Extinguisher › Condition
Issued 23 August 2002 Resolved
Provide extra fire extinguisher on port side of engine room.
Condition: Improper Installation
Action required: 17 - Rectify deficiencies prior to departure
Due 23 August 2002
Resolved 23 August 2002
Lifesaving › Lifebuoys › Markings (ship name/port)
Issued 23 August 2002 Resolved
Provide new retro tape on all life rings.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 23 August 2002
Resolved 23 August 2002
Lifesaving › Lifebuoys › Buoyant Lifeline
Issued 23 August 2002 Resolved
Provide new life lines for the port side foward life rings.
Condition: Improper Installation
Action required: 17 - Rectify deficiencies prior to departure
Due 23 August 2002
Resolved 23 August 2002
Accommodation/Occupational Safety › Medical/First Aid › Medicine Chest
Issued 23 August 2002 Resolved
Provide new first aid kit on crew accomodation space.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 23 August 2002
Resolved 23 August 2002
Fire Fighting › Miscellaneous Items
Issued 11 January 2002 Resolved
DEMONSTRATE PROPER OPERATION OF ENGINE ROOM GENERAL ALARM ROTATING BECON TO THE SATISFACTION OF THE ATTENDING MARINE INSPECTOR. LEGACY COMPONENT DESC: GENERAL ALARM BECON
Condition: Improper/Lack of Maintenance
Due 11 February 2002
Resolved 26 February 2002
Engineering › Fuel Oil Service System › Hose
Issued 11 January 2002 Resolved
STBD GEBERATOR SUPPLY FUEL OIL HOSE EXCESSIVLEY WORN. HOSE TO BE RENEWED.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 11 January 2002
Resolved 11 January 2002
Fire Fighting › Fire Pumps
Issued 11 January 2002 Resolved
FIRE PUMP PRESSURE GUAGE NOT WORKING. LEGACY COMPONENT DESC: GUAGE
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 11 January 2002
Resolved 11 January 2002
Communications › Internal Communications System
Issued 11 January 2002 Resolved
DEMONSTRATE PROPER OPERATION OF ENGINE ROOM SOUND POWERED PHONE UNDER EMERGENCY POWER TO THE SATISFACTION OF THE ATTENDING MARINE INSPECTOR. LEGACY COMPONENT DESC: Sound-powered Telephone
Condition: Improper/Lack of Maintenance
Due 11 February 2002
Resolved 26 February 2002
Construction/Loadline › Structures › Door
Issued 11 January 2002 Resolved
ADJUST ALL WATERTIGH DOORS PRIOR TO SAILING.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 11 January 2002
Resolved 11 January 2002
Documentation › Manuals/Policy Documentation
Issued 11 January 2002 Resolved
CURRENT LIGHT LIST NOT PROVIDED. LEGACY COMPONENT DESC: LIGHT LIST
Condition: Unknown
Due 11 January 2002
Resolved 11 January 2002
Lifesaving › Inflatable Liferafts
Issued 11 January 2002 Resolved
LIFE RAFT LOCATIONS NOT STENCILED. LEGACY COMPONENT DESC: STENCILING
Condition: Unknown
Action required: 17 - Rectify deficiencies prior to departure
Due 11 January 2002
Resolved 11 January 2002
Accommodation/Occupational Safety › Ventilation
Issued 11 January 2002 Resolved
FLAME SCREEN NOT INSTALLED IN SEWAGE VENT. LEGACY COMPONENT DESC: SEWAGE VENT FLAME SCREEN.
Condition: Improper/Lack of Maintenance
Due 11 January 2002
Resolved 11 January 2002
Engineering › Bilge Water Management System › Valve
Issued 11 January 2002 Resolved
FOREPEAK REACHROD NOT WORKING. REPAIR PRIOR TO SAILING.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 11 January 2002
Resolved 11 January 2002
Fire Fighting › Fixed Fire Detection System
Issued 11 January 2002 Resolved
DEMONSTRATE PROPER OPERATION OF ALL SMOKE DETECTORS TO THE SATISFACTION OF THE ATTENDING MARINE INSPECTOR. LEGACY COMPONENT DESC: Smoke Detectors
Condition: Improper/Lack of Maintenance
Due 11 February 2002
Resolved 26 February 2002
Lifesaving
Issued 4 April 2001 Resolved
INSTALL THREE EMERGENCY LIGHTS IN THE BOW THRUSTER HALLWAY AND ABOVE ENGINEROOM LADDER TO THE SATISFACTION OF THE ATTENDING MARINE INSPECTOR.
Condition: Unknown
Due 4 April 2001
Resolved 4 April 2001
Construction/Loadline
Issued 4 April 2001 Resolved
INSTALL AND DEMONSTRATE PROPER OPERATION OF A HIGH BILGE ALARM IN THE RUDDER ROOM TO THE SATISFACTION OF THE ATTENDING MARINE INSPECTOR.
Condition: Unknown
Due 4 April 2001
Resolved 4 April 2001
Electrical
Issued 4 April 2001 Resolved
DEMONSTRATE PROPER OPERATION OF GROUND FAULT INDICATOR LIGHTS ON THE MAIN DISTRIBUTION PANEL TO THE SATISFACTION OF THE ATTENDING MARINE INSPECTOR.
Condition: Unknown
Due 4 April 2001
Resolved 4 April 2001
Electrical
Issued 4 April 2001 Resolved
DEMONSTRATE PROPER OPERATION OF PILOT HOUSE AND ENGINE ROOM ALARM PANELS TOINCLUDE OPERATION OF ALL MACHINERY INDICATOR LIGHTS TO THE SATISFACTION OF THE ATTENDING MARINE INSPECTOR.
Condition: Unknown
Due 4 April 2001
Resolved 4 April 2001
Engineering
Issued 16 January 1998 Resolved
Repair or replace engine room port shaft tachometer and demonstrate operation.
Condition: Unknown
Due 16 January 1998
Resolved 16 January 1998
Engineering
Issued 16 January 1998 Resolved
Prior to energizing bow and or stern thrusters station a member of the engineering department at each thruster engine in use and equip each stand by engineer with a VHF radio for contact with the bridge and demonstrate pilot house thruster engine stops.
Condition: Unknown
Due 21 January 1998
Resolved 21 January 1998
Deck/Cargo
Issued 19 July 1994 Resolved
GAS-FREE AND MAKE AVAILABLE FOR INTERNAL EXAMINATION ALL SIX (6) DRY BULK PRESSURE TANKS.
Condition: Unknown
Due 19 July 1994
Resolved 19 July 1994
Construction/Loadline
Issued 8 April 1994 Resolved
Crop and renew side shell and associated frames as necessary to make permanent repairs in way of #2 & 3 fuel oil tanks (stbd side midships).
Condition: Unknown
Due 8 April 1994
Resolved 8 April 1994
Engineering
Issued 28 July 1992 Resolved
RECALIBRATE AND PROVE PROPER OPERATION OF FOLLOWING AUTOMATION PROCEDURES: P&S MDE OIL PRES#2;P&S MDE THROTTLE AIR; CLUTCH LOW PRES; STERN&BOW THRUST.GEAR OIL&OIL PRES;1&2 MUD PUMPS OIL PRES; AND ALL TEMPERATURE SET POINTS TOSATISFACTION OF ATTENDING USCG INSPECTOR.
Condition: Unknown
Due 28 July 1992
Resolved 28 July 1992
Deck/Cargo
Issued 28 July 1992 Resolved
GAS-FREE AND MAKE AVAILABLE FOR INSPECTION ALL DRY BULK TANKS FOR INTERNAL INSPECTION BY ATTENDING USCG INSPECTOR AT OR BEFORE NEXT DRYDOCKING.
Condition: Unknown
Due 28 July 1992
Resolved 28 July 1992
Unknown
Issued 22 August 1989 Resolved
PROVIDE A DEVIATION TABLE FOR VESSEL. IAW GOOD MARINE PRACTICE.
Condition: Unknown
Due 22 August 1989
Resolved 22 August 1989

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.