MAURY USCG vessel records Sign in
← All vessels

GULF FLEET NO. 62

GULF FLEET NO. 62 is a 1983 offshore supply vessel. The Coast Guard has recorded 52 inspections since 1983, most recently in February 2005, along with 118 deficiencies.

Records from 1983 to 2005. Most recent: inspection, 16 February 2005.

Built
1983
Last inspected
16 February 2005
Documentation
Not in the documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

8216588 View on MarineTraffic leaves Maury; a third-party site, nothing from it is stored here
WBQ2687
Flag
UNITED STATES
—
Maury page id
psix-54879

Inspections, by type

…with no type recorded10
Years with a record 20 calendar years (1983–2005)
The 52 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

This record may be incomplete: the most recent inspection recorded for this vessel was 21 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Offshore class in Maury's sources begin in 1978.

Documentation record

Tonnage as PSIX records it286 - Regulatory (Subpart C or D), Gross Ton
738 - Convention (Subpart B), Gross Ton
194 - Regulatory (Subpart C or D), Net Ton
221 - Convention (Subpart B), Net Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.

Radio station licence

WBQ2687MMSI not assigned · cancelled · compulsorily equipped · granted 9 December 1997, cancelled 4 December 2007
FCC Universal Licensing System ship-station file of 6 September 2026, matched to this hull on its US Official Number. Status and dates are the file’s own. The licensee is not read from the file and is not shown. A lapsed licence’s MMSI is still the number the vessel transmitted under while it was valid.

A report is not offered for this hull: Its record holds only 2 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. Reports.

Inspection history · 52

16 February 2005 Administrative Inspection
Administrative · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 2293515
11 October 2001 Administrative
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1075340
3 August 2001 Administrative
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1075044
17 July 2001 Re-Inspection
Physical examination · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1470035
25 April 2001 Examination of Repairs
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1062354
1 September 2000 Deficiency Check
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1055051
13 July 2000 COI Inspection
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1376267
13 April 2000 Administrative
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1049201
17 November 1999 Deficiency Check
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 809544
5 November 1999 Deficiency Check
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 804820
2 September 1999 Re-Inspection
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1466073
30 September 1998 Deficiency Check
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 801826
17 July 1998 Administrative
Administrative · Activities Europe · Activity 794155
17 July 1998 Hull Examination · COI Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1404591
14 July 1998 Type not recorded
No type recorded · Activities Europe · Activity 665626
13 July 1998 Type not recorded
No type recorded · Activities Europe · Activity 665627
2 February 1998 Type not recorded
No type recorded · Activities Europe · Activity 213341
16 January 1998 Administrative
Administrative · Activities Europe · Activity 1368550
30 June 1997 Administrative
Administrative · Activities Europe · Activity 1113026
27 February 1997 COI Inspection
Physical examination · Activities Europe · Activity 1120941
5 December 1996 Re-Inspection
Physical examination · Activities Europe · Activity 1098236
12 September 1996 Administrative
Administrative · Activities Europe · Activity 951484
10 April 1996 Excursion Permit
Administrative · Activities Europe · Activity 1079752
18 March 1996 Administrative
Administrative · Activities Europe - OLD · USCG Northeast District (CGD-NE) · Activity 884604
7 October 1995 Hull Examination · COI Inspection
Physical examination · Activities Europe - OLD · USCG Northeast District (CGD-NE) · Activity 1355440
16 February 1994 Deficiency Check
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1163401
23 October 1993 COI Inspection
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 848409
18 May 1993 Hull Examination
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 846989
19 April 1993 Re-Inspection
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 826761
14 April 1993 Type not recorded
No type recorded · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 846795
20 May 1992 Administrative
Administrative · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 959426
27 February 1992 Administrative
Administrative · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 962293
6 February 1992 COI Inspection
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 946411
1 October 1991 Deficiency Check
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 934662
28 May 1991 Administrative
Administrative · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 940357
23 May 1991 Administrative
Administrative · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 937200
27 February 1991 Re-Inspection
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1246831
29 January 1991 Type not recorded
No type recorded · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 929771
13 September 1990 Hull Examination
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1214963
22 June 1990 Administrative
Administrative · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 911910
5 February 1990 COI Inspection
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1227481
3 May 1989 Deficiency Check
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1034776
14 March 1989 Hull Examination · Re-Inspection
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1040167
14 March 1989 MARPOL Annex II Examination
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1198410
17 February 1988 COI Inspection
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1022464
24 January 1987 Re-Inspection
Physical examination · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1325957
19 February 1986 COI Inspection · Credit Drydock
Physical examination · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1301263
3 November 1985 Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1297106
17 July 1985 Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1288293
5 May 1985 Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1288263
18 April 1984 Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1281203
28 April 1983 Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 969032

Deficiency record · 118

Engineering
Issued 13 July 2000 Resolved
RENEW OR REPAIR BOTH ENGINEROOM RPM GAUGES.
Condition: Unknown
Due 13 July 2000
Resolved 13 July 2000
Documentation
Issued 13 July 2000 Resolved
PROVIDE ONBOARD, UPDATED AND APPROVED FIRE CONTROL AND SAFETY PLAN.
Condition: Unknown
Due 13 July 2000
Resolved 13 July 2000
Lifesaving
Issued 13 July 2000 Resolved
PROVIDE PROPER MARKINGS FOR PORT AND STARBOARD EMBARKATION STATIONS.
Condition: Unknown
Due 13 July 2000
Resolved 13 July 2000
Documentation
Issued 13 July 2000 Resolved
PROVIDE ONBOARD, ORIGINAL SHIP/AIRCRAFT RADIO STATION LICENSE.
Condition: Unknown
Due 14 July 2000
Resolved 14 July 2000
Navigation
Issued 13 July 2000 Resolved
PROVE PROPER OPERATION OF MID (WHITE) LIGHT FOR RESTRICTED MANEUVERING LIGHTS.
Condition: Unknown
Due 13 July 2000
Resolved 13 July 2000
Documentation
Issued 13 July 2000 Resolved
PROVIDE ONBOARD, NEW CERTIFICATE OF DOCUMENTATION WITH UP TO DATE ANNUAL STICKER.
Condition: Unknown
Due 14 July 2000
Resolved 14 July 2000
Deck/Cargo
Issued 13 July 2000 Resolved
PROPERLY MARK FUEL OIL AND LIQUID MUD HOSES WITH SERVICE INTENDED.
Condition: Unknown
Due 13 July 2000
Resolved 13 July 2000
Accommodation/Occupational Safety
Issued 13 July 2000 Resolved
INSTALL 100 PSI OR LOWER PRESSURE/TEMPERATURE RELIEF VALVE ON HOT WATER HEATER.
Condition: Unknown
Due 13 July 2000
Resolved 13 July 2000
Accommodation/Occupational Safety
Issued 13 July 2000 Resolved
RENEW PORT LIGHT COVER IN MATES ROOM.
Condition: Unknown
Due 13 July 2000
Resolved 13 July 2000
Fire Fighting
Issued 13 July 2000 Resolved
PROVIDE SYSTEM SCHEMATIC FOR FIXED CO2 SYSTEM OPERATION STATIONS.(REMOTE AND LOCAL). - MARL ALL PERTINENT COMPONENTS-ie. VALVES,ETC.
Condition: Unknown
Due 13 July 2000
Resolved 13 July 2000
Accommodation/Occupational Safety
Issued 13 July 2000 Resolved
PROPERLY SECURE LOCKER IN MATES CABIN.
Condition: Unknown
Due 13 July 2000
Resolved 13 July 2000
Deck/Cargo
Issued 13 July 2000 Resolved
REPLACE FLAME SCREEN IN VENT FOR PORT #4 FUEL OIL TANK.
Condition: Unknown
Due 13 July 2000
Resolved 13 July 2000
Construction/Loadline
Issued 13 July 2000 Resolved
RENEW BROKEN GLASS IN PORT PILOT HOUSE WATERTIGHT DOOR.
Condition: Unknown
Due 13 July 2000
Resolved 13 July 2000
Construction/Loadline
Issued 13 July 2000 Resolved
INSTALL HARD RUBBER GASKET MATERIAL IN ALL WATERTIGHT FITTINGS, MAIN DECK AND BELOW.
Condition: Unknown
Due 13 July 2000
Resolved 13 July 2000
Navigation
Issued 2 September 1999 Resolved
INSTALL PORT AND STBD RUDDER STOPS IN STEERING GEAR ROOM.
Condition: Unknown
Due 2 September 1999
Resolved 2 September 1999
Navigation
Issued 2 September 1999 Resolved
REPAIR HYDRAULIC LEAK ON PORT SIDE OF STEERING GEAR PIPING.
Condition: Unknown
Due 2 September 1999
Resolved 2 September 1999
Lifesaving
Issued 2 September 1999 Resolved
PROVIDE NEW EPIRB WITH REGISTRATION STICKER.
Condition: Unknown
Due 2 September 1999
Resolved 2 September 1999
Engineering
Issued 2 September 1999 Resolved
REPLACE NO.2 REMOTE FUEL SHUTDOWN.
Condition: Unknown
Due 2 September 1999
Resolved 2 September 1999
Electrical
Issued 2 September 1999 Resolved
REMOVE DEADEND WIRES AND WIRE NUTS ON MAST.
Condition: Unknown
Due 2 September 1999
Resolved 2 September 1999
Construction/Loadline
Issued 2 September 1999 Resolved
ADD CABLE CLAMP TO STBD MAST STAY.
Condition: Unknown
Due 2 September 1999
Resolved 2 September 1999
Navigation
Issued 2 September 1999 Resolved
PROVIDE UP TO DATE MAGNETIC COMPASS DEVIATION TABLE.
Condition: Unknown
Due 2 September 1999
Resolved 2 September 1999
Navigation
Issued 2 September 1999 Resolved
PROVE PROPER OPERATION OF NAV LIGHT ALARM PANEL.
Condition: Unknown
Due 2 September 1999
Resolved 2 September 1999
Electrical
Issued 2 September 1999 Resolved
REMOVE DEADEND WIRE FROM STBD DECK GEAR LOCKER.
Condition: Unknown
Due 2 September 1999
Resolved 2 September 1999
Fire Fighting
Issued 2 September 1999 Resolved
REPLACE ER CO2 REMOTE PULL BOX COVER WITH GLASS AND PROPERLY LABEL.
Condition: Unknown
Due 2 September 1999
Resolved 2 September 1999
Lifesaving
Issued 2 September 1999 Resolved
ADD REFLECTIVE TAPE AND REPLACE LINE ON PORT CARGO DECK LIFE RING.
Condition: Unknown
Due 2 September 1999
Resolved 2 September 1999
Deck/Cargo
Issued 2 September 1999 Resolved
PROPERLY LABEL LIQUID MUD PUMP REMOTE SHUTDOWN ON PORTSIDE OF CARGO DECK.
Condition: Unknown
Due 2 September 1999
Resolved 2 September 1999
Deck/Cargo
Issued 2 September 1999 Resolved
PROPERLY LABEL DIRTY OIL PUMP REMOTE SHUTDOWN ON STBD SIDE OF CARGO DECK.
Condition: Unknown
Due 2 September 1999
Resolved 2 September 1999
Fire Fighting
Issued 2 September 1999 Resolved
PROVE FIRE EXTINGUISH NO.15 IN ENGINE ROOM COMPLETED ANNUAL SERVICING OR REPLACE WITH AN UP TO DATE EXTINGUISHER.
Condition: Unknown
Due 2 September 1999
Resolved 2 September 1999
Engineering
Issued 2 September 1999 Resolved
REPAIR FUEL OIL LEAK IN FUEL OIL MANIFOLD PIPING IN ENGINE ROOM.
Condition: Unknown
Due 2 September 1999
Resolved 2 September 1999
Construction/Loadline
Issued 2 September 1999 Resolved
REPAIR HOLE IN MAIN DECK WHERE PORT MDE EXHAUST EXITS ENGINE ROOM.
Condition: Unknown
Due 2 September 1999
Resolved 2 September 1999
Navigation
Issued 2 September 1999 Resolved
PROVE PROPER OPERATION OF MAGNETIC COMPAS LIGHT.
Condition: Unknown
Due 2 September 1999
Resolved 2 September 1999
Electrical
Issued 2 September 1999 Resolved
REMOVE DEADEND WIRES AND WIRE NUTS FROM UNDER FWD AND AFT BRIDGE CONSOLE.
Condition: Unknown
Due 2 September 1999
Resolved 2 September 1999
Lifesaving
Issued 2 September 1999 Resolved
PROVIDE THREE ADDITIONAL ROCKET CHARGES FOR SPEED LINE (FOR A TOTAL OF FOUR).
Condition: Unknown
Due 2 September 1999
Resolved 2 September 1999
Electrical
Issued 2 September 1999 Resolved
REMOVE WIRE NUTS AND SECURE DEADEND WIRES ON STBD MUD PUMP ENGINE.
Condition: Unknown
Due 2 September 1999
Resolved 2 September 1999
Deck/Cargo
Issued 2 September 1999 Resolved
REPLACE PRESSURE RELIEF VALVES ON PORT AND STBD AIR RECEIVERS WITH A 175PSIVALE SET BY AN APPROVED ASME SHOP.
Condition: Unknown
Due 2 September 1999
Resolved 2 September 1999
Fire Fighting
Issued 2 September 1999 Resolved
PROVIDE APPROVED FIRE AND SAFETY PLAN.
Condition: Unknown
Due 2 September 1999
Resolved 2 September 1999
Lifesaving
Issued 17 July 1998 Resolved
Update vessel ops/training manual to reflect use of "JASON CRADLE".
Condition: Unknown
Due 17 July 1998
Resolved 17 July 1998
Lifesaving
Issued 17 July 1998 Resolved
Provide suitable rescue boat and embarkation, launching and recovery arrangements as per 46CFR133.135 and 46CFR133.160 to the satisfaction of attending marine inspector.
Condition: Unknown
Due 17 July 1998
Resolved 17 July 1998
Lifesaving
Issued 27 February 1997 Resolved
Provide equipment for rescue boat as per 46 CFR 133.175._x001C_ _x001C_ _x001C_ _x001C_
Condition: Unknown
Due 7 October 1997
Resolved 25 March 1998
Navigation
Issued 27 February 1997 Resolved
Provide current Local Notices to Mariners.
Condition: Unknown
Due 7 April 1998
Resolved 25 March 1998
Lifesaving
Issued 27 February 1997 Resolved
Provide suitable rescue boat as per 46 CFR 133.135.
Condition: Unknown
Due 7 October 1997
Resolved 25 March 1998
Electrical
Issued 27 February 1997 Resolved
Remove jury rigged wiring and dead ended cables to the satisfaction of the attending ABS surveyor.
Condition: Unknown
Due 7 April 1998
Resolved 25 March 1998
Accommodation/Occupational Safety
Issued 27 February 1997 Resolved
Renew/repair galley extraction fan and filter to the satisfaction of the attending ABS surveyor.
Condition: Unknown
Due 7 April 1998
Resolved 25 March 1998
Accommodation/Occupational Safety
Issued 27 February 1997 Resolved
Properly secure washing machine and dryer to the satisfaction of the attending ABS surveyor.
Condition: Unknown
Due 7 April 1998
Resolved 25 March 1998
Construction/Loadline
Issued 27 February 1997 Resolved
Renew port hawse pipe to the satisfaction of the attending ABS surveyor.
Condition: Unknown
Due 7 April 1998
Resolved 25 March 1998
Deck/Cargo
Issued 27 February 1997 Resolved
Renew damaged anchor chain to the satisfaction of the attending ABS surveyor.
Condition: Unknown
Due 7 April 1998
Resolved 25 March 1998
Fire Fighting
Issued 27 February 1997 Resolved
Provide approved fire extinguisher as per 46 CFR 132.220 (a) for the paint locker.
Condition: Unknown
Due 7 April 1998
Resolved 25 March 1998
Engineering
Issued 27 February 1997 Resolved
Prove proper operation of the port MDE wheelhouse shut down to the satisfaction of the attending ABS surveyor.
Condition: Unknown
Due 7 April 1998
Resolved 25 March 1998
Documentation
Issued 27 February 1997 Resolved
Prior to operation a valid COI must be onboard.
Condition: Unknown
Due 7 October 1997
Resolved 25 March 1998
Accommodation/Occupational Safety
Issued 27 February 1997 Resolved
Prove proper operation of the remote emergency shutdown for the accomodation ventilation to the satisfaction of the attending ABS surveyor.
Condition: Unknown
Due 7 April 1998
Resolved 25 March 1998
Electrical
Issued 27 February 1997 Resolved
Provide lead lining to battery box located on the stbd bridge deck to the satisfaction of the attending ABS surveyor.
Condition: Unknown
Due 7 April 1998
Resolved 25 March 1998
Construction/Loadline
Issued 27 February 1997 Resolved
Make hull markings (name, hailing port and loadline marks) visible to the satisfaction of the attending ABS surveyor.
Condition: Unknown
Due 7 April 1998
Resolved 25 March 1998
Construction/Loadline
Issued 27 February 1997 Resolved
Repair all watertight doors to ensure correct seal.
Condition: Unknown
Due 7 October 1997
Resolved 25 March 1998
Fire Fighting
Issued 27 February 1997 Resolved
Prove proper operation of fire pump as per 46 CFR 132.120(a).
Condition: Unknown
Due 7 October 1997
Resolved 25 March 1998
Fire Fighting
Issued 27 February 1997 Resolved
Provide suitable fire hose which meets 46 CFR 132.130(n) for a total lengthof 250 feet.
Condition: Unknown
Due 7 October 1997
Resolved 25 March 1998
Fire Fighting
Issued 27 February 1997 Resolved
Complete hydrostatic test of all fire hose to the satisfaction of the attending ABS surveyor.
Condition: Unknown
Due 7 April 1997
Resolved 25 March 1998
Lifesaving
Issued 27 February 1997 Resolved
Provide liferafts that have been serviced at a USCG approved facility.
Condition: Unknown
Due 7 October 1997
Resolved 25 March 1998
Documentation
Issued 27 February 1997 Resolved
Provide Fire Control Plan as per 46 CFR 131.945.
Condition: Unknown
Due 7 April 1998
Resolved 25 March 1998
Navigation
Issued 27 February 1997 Resolved
Provide current deviation table for magnetic compass.
Condition: Unknown
Due 7 April 1998
Resolved 25 March 1998
Electrical
Issued 27 February 1997 Resolved
Provide illumination for liferaft launching station as per 46 CFR 133.110(d). Power is to be supplied by emergency source of electrical power._x001C_
Condition: Unknown
Due 7 April 1998
Resolved 25 March 1998
Electrical
Issued 27 February 1997 Resolved
Repair defective and illegal wiring connections to the satisfaction of the attending ABS surveyor.
Condition: Unknown
Due 7 April 1998
Resolved 25 March 1998
Engineering
Issued 7 October 1995 Resolved
INTALL E/R POWER VENTILATION SUPPLY.
Condition: Unknown
Due 1 November 1995
Resolved 12 December 1995
Construction/Loadline
Issued 7 October 1995 Resolved
C & R BOTTOM LONG, APPROX. 1 M, #6 INBOARD OF MH IWO PORT, AFT P-TANK VOID.
Condition: Unknown
Due 7 October 1995
Resolved 7 October 1995
Engineering
Issued 7 October 1995 Resolved
PROVE OPERATION OF THE FOLLOWING POINTS MONITORED BY THE VESSEL'S AUTOMATION/MONITORING SYSTEM: STBD, M/E HIGH OIL TEMP., PORT RED. GEAR HIGH OIL TEMP., #1 GENERATOR HIGH WATER TEMP. AND BILGE HIGH LEVEL ALARM.
Condition: Unknown
Due 26 October 1995
Resolved 12 December 1995
Electrical
Issued 23 October 1993 Resolved
LINE ENGINEROOM BATTERY BOXES WITH CORROSION-RESISTANT MATERIAL NLT 01DEC93.
Condition: Unknown
Due 23 October 1993
Resolved 23 October 1993
Fire Fighting
Issued 23 October 1993 Resolved
HYDRO THE (2) U.S. DOT APPROVED CYLINDERS FOR THE ENGINEROOM FIXED CO2 SYSTEM REPLACE THE (7) U.K. DOT APPROVED CYLINDERS WITH U.S.S DOT APPROVED CYLINDERS. REPLACE THE PILOT BOTTLE IN THE DECK CONTROL BOX WITH A U.S. DOTAPPROVED BOTTLE TO BE COMPLETED NLT 30MAY94.
Condition: Unknown
Due 23 October 1993
Resolved 23 October 1993
Lifesaving
Issued 23 October 1993 Resolved
REPLACE MISSING SERVICE LINES (2) AND AUXILIARY LINE FOR LINE THROWING GUN NLT 30DEC93.
Condition: Unknown
Due 23 October 1993
Resolved 23 October 1993
Deck/Cargo
Issued 23 October 1993 Resolved
HAVE THE AFT PORT AND STBD DRY BULK TANKS (LOCATED IN #5 & #6 VOIDS) INTERNALLY INSPECTED BY A COAST GUARD MARINE INSPECTOR NLT 30SEP94.
Condition: Unknown
Due 23 October 1993
Resolved 23 October 1993
Electrical
Issued 23 October 1993 Resolved
REPLACE MISSING GUARD ON COMPRESSOR FAN IN WALKIN FREEZER NLT 30DEC93.
Condition: Unknown
Due 23 October 1993
Resolved 23 October 1993
Deck/Cargo
Issued 23 October 1993 Resolved
PRIOR TO THE TRANSFER OF GRADE "E" LIGUID MUD (OR NLT NEXT DRYDOCK) PROVIDEPERMANENT CONTAINMENT AROUND THE LIGUID MUD DECK CONNECTIONS (33 CFR 155.310) AND REPLACE EMERGENCY SHUTDOWN CONTROL BOX PORT SIDE MAIN DECK (NEXT DRYDOCK IS 30SEP95).
Condition: Unknown
Due 23 October 1993
Resolved 23 October 1993
Engineering
Issued 23 October 1993 Resolved
REPAIR PORT AND STBD SHAFT TACHS ON BRIDGE NLT 30DEC93.
Condition: Unknown
Due 23 October 1993
Resolved 23 October 1993
Unknown
Issued 18 May 1993 Resolved
REPLACE NAVIGATION LIGHT INDICATOR PANEL WITH ONE IN ACCORDANCE WITH 46 CFR111.75-17.
Condition: Unknown
Due 15 July 1993
Resolved 15 July 1993
Engineering
Issued 19 April 1993 Resolved
PROVIDE AND TEST OPERATION OF PORT SHIP SVC DIESEL GENERATOR TACHOMETER.
Condition: Unknown
Due 10 May 1993
Resolved 10 May 1993
Engineering
Issued 19 April 1993 Resolved
REPLACE FUEL TANK VENTILATION SCREENS/VENT BALLS. 4 TOTAL - 2 X 5" AND 2 X3".
Condition: Unknown
Due 10 May 1993
Resolved 10 May 1993
Navigation
Issued 19 April 1993 Resolved
REPAIR AND PROVE PROPER OPERATION OF "ALDIS" SIGNALING LAMP.
Condition: Unknown
Due 10 May 1993
Resolved 10 May 1993
Fire Fighting
Issued 19 April 1993 Resolved
REPLACE FIRE PUMP DISCHARGE PSI GAUGE.
Condition: Unknown
Due 10 May 1993
Resolved 10 May 1993
Construction/Loadline
Issued 19 April 1993 Resolved
PERMANENTLY REPAIR 6' X 4" WASTED BILGE PUMP SUCTION PIPING.
Condition: Unknown
Due 10 May 1993
Resolved 10 May 1993
Lifesaving
Issued 19 April 1993 Resolved
REPAIR PAINT LOCKER DOOR HINGES AND PROVE PROPER OPERATION.
Condition: Unknown
Due 10 May 1993
Resolved 10 May 1993
Construction/Loadline
Issued 19 April 1993 Resolved
REPAIR WASTED PORT ENGINE ROOM ESCAPE HATCH GASKET RECESS AND PROVE PROPER OPERATION.
Condition: Unknown
Due 10 May 1993
Resolved 10 May 1993
Engineering
Issued 19 April 1993 Resolved
PROVE PROPER OPERATION OF STBD ENGINE ROOM AIR RECEIVER. THE ABOVE ITEMS 1THRU 13 ARE TO BE COMPLETED TO THE SATISFACTION OF THE ATTENDING MARINE INSPECTOR.
Condition: Unknown
Due 10 May 1993
Resolved 10 May 1993
Engineering
Issued 19 April 1993 Resolved
REPLACE WASTED BOW THRUSTER FUEL SUPPLY PIPING. APPROX 20' X 1".
Condition: Unknown
Due 10 May 1993
Resolved 10 May 1993
Lifesaving
Issued 19 April 1993 Resolved
PROVIDE LEDGIBLE LIFE RAFT SERVICING REPORTS.
Condition: Unknown
Due 10 May 1993
Resolved 10 May 1993
Fire Fighting
Issued 19 April 1993 Resolved
PERMANENTLY REPAIR 10' X 3" WASTED FIRE PUMP SUCTION PIPING.
Condition: Unknown
Due 10 May 1993
Resolved 10 May 1993
Fire Fighting
Issued 19 April 1993 Resolved
REPLACE FIRE STATION #3 SPANNER WRENCH.
Condition: Unknown
Due 10 May 1993
Resolved 10 May 1993
Fire Fighting
Issued 19 April 1993 Resolved
SERVICE ALL ENGINE ROOM FIXED CO2 BOTTLES.
Condition: Unknown
Due 10 May 1993
Resolved 10 May 1993
Engineering
Issued 27 February 1991 Resolved
REPLACE RELIEF VALVE FOR PORT AIR RECEIVER AND CHECK TOP OFF PRESSURE.
Condition: Unknown
Due 27 February 1991
Resolved 27 February 1991
Fire Fighting
Issued 27 February 1991 Resolved
REPLACE PRESSURE GAUGE ON FIRE PUMP LOCATED IN ENGINEROOM.
Condition: Unknown
Due 27 February 1991
Resolved 27 February 1991
Electrical
Issued 27 February 1991 Resolved
PROVE PROPER OPERATION OF SMOKE DETECTION SYSTEM AND ALL ALARMS.
Condition: Unknown
Due 27 February 1991
Resolved 27 February 1991
Lifesaving
Issued 27 February 1991 Resolved
CONDUCT MAN OVERBOARD/RESCUE BOAT DRILL.
Condition: Unknown
Due 27 February 1991
Resolved 27 February 1991
Documentation
Issued 29 January 1991 Resolved
PROVIDE ALTERNATE REINSPECTION CHECK LIST AND WRITTEN REPORTS AS REQUIRED BY 46 CFR 91.27-13(D)(3). SUBMIT TO [name withheld] FOR REVIEW AND CREDIT OFEXAM.
Condition: Unknown
Due 29 January 1991
Resolved 29 January 1991
Electrical
Issued 5 February 1990 Resolved
REMOVE TEMPORARY WIRING AND PROPERLY INSTALL APPROVED CABLE AND CABLE RUN IAW 46 CFR FOR VESSELS CLOTHES DRYER AND SECURE DRYER TO DECK.
Condition: Unknown
Due 5 February 1990
Resolved 5 February 1990
Lifesaving
Issued 5 February 1990 Resolved
REPLACE ALL OUTDATED BRIDGE PYROTECHNIC.
Condition: Unknown
Due 5 February 1990
Resolved 5 February 1990
Lifesaving
Issued 5 February 1990 Resolved
HAVE SERVICE AT CG APPROVED FACILITY BOTH OF VESSELS LIFERAFTS AND HYDROSTATIC RELEASES.
Condition: Unknown
Due 5 February 1990
Resolved 5 February 1990
Fire Fighting
Issued 5 February 1990 Resolved
REPLACE REMOTE E/R CO2 ACTIVATION BOX WITH WEATHER TIGHT BOX.
Condition: Unknown
Due 5 February 1990
Resolved 5 February 1990
Electrical
Issued 5 February 1990 Resolved
REPLACE BOW FLOODLIGHT ELECTRICAL BOX WITH WATERTIGHT BOX.
Condition: Unknown
Due 5 February 1990
Resolved 5 February 1990
Engineering
Issued 5 February 1990 Resolved
REPAIR OR REPLACE BOTH MAIN ENGINE HIGH TEMPERATURE ALARMS.
Condition: Unknown
Due 5 February 1990
Resolved 5 February 1990
Engineering
Issued 5 February 1990 Resolved
REPLACE ALL BURNED OUT LIGHTS ON ENGINE ROOM ALARM PANEL.
Condition: Unknown
Due 5 February 1990
Resolved 5 February 1990
Electrical
Issued 3 May 1989 Resolved
MAKE OPERABLE THE PORT GENERATOR OVERSPEED TRIP AND GENERATOR TACHOMETER.
Condition: Unknown
Due 3 May 1989
Resolved 3 May 1989
Lifesaving
Issued 14 March 1989 Resolved
PROVIDE TWO NEW LIFERAFS OR HAVE THE LIFERAFTS ON BOARD SERVICED.
Condition: Unknown
Due 14 March 1989
Resolved 14 March 1989
Engineering
Issued 14 March 1989 Resolved
IN THE PRESENCE OF A USCG MARINE INSPECTOR PROVE THE PROPER OPERATION OF ALL ALARMS AND SHUTDOWNS FOR THE GENERATORS AND MAIN ENGINES.
Condition: Unknown
Due 14 March 1989
Resolved 14 March 1989
Electrical
Issued 14 March 1989 Resolved
PROVIDE GLOBES FOR THE LIGHTS IN THE ENGINEROOM AND PROVIDE LIGHT COVERS FOR BUNK LIGHTS AND BATHROOM LIGHTS.
Condition: Unknown
Due 14 March 1989
Resolved 14 March 1989
Deck/Cargo
Issued 14 March 1989 Resolved
IN THE PRESENCE OF A USCG MARINE INSPECTOR TEST ALL SIX DRY BULK TANK SAFETY RELIEF VALVES.
Condition: Unknown
Due 14 March 1989
Resolved 14 March 1989
Navigation
Issued 14 March 1989 Resolved
PROVIDE TO THE [name withheld] A TELEX OR FAX FROM THE MASTER OF THE VESSEL ATTESTING TO THE OPERATION OF THE STEERING GEAR IN ALL MODES FROM ALL STATIONS INCLUDING INSPECTION OF THE STEERING COMPARTMENT AFTER THE VESSEL IS REFLOATED.
Condition: Unknown
Due 14 March 1989
Resolved 14 March 1989
Engineering
Issued 14 March 1989 Resolved
REPAIR OR REPLACE THE FUEL PUMP EMERGENCY SHUT OFF LOCATED OUTSIDE THE THE ENGINEROOM STARBOARD EMERGENCY ESCAPE TRUNK.
Condition: Unknown
Due 14 March 1989
Resolved 14 March 1989
Lifesaving
Issued 14 March 1989 Resolved
HYDROSTATICALLY TEST OR PROVIDE A NEW AIR CYLINDER FOR THE SELF CONTAINED BREATHING APPARATUS.
Condition: Unknown
Due 14 March 1989
Resolved 14 March 1989
Electrical
Issued 5 May 1985 Resolved
RENEW CABLES FOR BOTH GENERATOR TACHOMETERS PRIOR TO 06JUN85.
Condition: Unknown
Due 5 May 1985
Resolved 5 May 1985
Engineering
Issued 5 May 1985 Resolved
MAKE AVAILABLE A TEST KIT FOR CARRYING OUT THE NECESSARY AUTOMATION TEST PROCEDURE TO SET M.E. AND GEN. HIGH OIL AND HIGH WATER TEMP AND RED GEAR HIGH OIL TEMP TEST THE ABOVE AS PER SENSOR DAMP SHEET PRIOR TO 05JUN85.
Condition: Unknown
Due 5 May 1985
Resolved 5 May 1985
Fire Fighting
Issued 5 May 1985 Resolved
RESERVICE ALL NINE BOTTLES AT AN AUTHORIZED SERVICE FACILITY FOR CHEMETROM/CARDOX FIRE SYSTEM NO LATER THAN 12MAY85 AS PER 46 CFR 91.25-20 (A)(2).
Condition: Unknown
Due 5 May 1985
Resolved 5 May 1985
Fire Fighting
Issued 5 May 1985 Resolved
SERVICE 150# DRY CHEMICAL EXTINGUISHER TO DETERMINE CHARGE IS AS SHOWN ON GUAGE AND HANDWHEEL WILL MOVE PRIOR TO 19MAY85. AS PER 46 CFR 91.25-20 (A)(1) AND (2).
Condition: Unknown
Due 5 May 1985
Resolved 5 May 1985
Deck/Cargo
Issued 5 May 1985 Resolved
INSTALL PORT ANCHOR PRIOR TO 05JUN83 AS PER 46 CFR 96.07-5(A) AND ABS RULES.
Condition: Unknown
Due 5 May 1985
Resolved 5 May 1985
Fire Fighting
Issued 5 May 1985 Resolved
RENEW THE PORTABLE FIRE EXTINGUISHER FOR THE PAINT LOCKER WITH A COAST GUARD APPROVED BII FIRE EXTINGUISHER PRIOR TO 19MAY85. AS PER 46 CFR 95.05-15(A).
Condition: Unknown
Due 5 May 1985
Resolved 5 May 1985
Deck/Cargo
Issued 5 May 1985 Resolved
RENEW ONE BULK TANK RELIEF VALVE AND SET AT OR BELOW 42 PSI PRIOR TO 05JUN85. AS PER 46 CFR 54.15-10(A).
Condition: Unknown
Due 5 May 1985
Resolved 5 May 1985
Navigation
Issued 5 May 1985 Resolved
REPAIR EMERGENCY RUDDER ANGLE INDICATOR IN ENGINE ROOM AND PROVE PROPER OPERATION OF SAME PRIOR TO 05JUN85. AS PER 46 CFR 113.40-(C).
Condition: Unknown
Due 5 May 1985
Resolved 5 May 1985
Electrical
Issued 5 May 1985 Resolved
INSTALL BATTERY CHARGER FOR PORT SHIPS SERVICE GENERATOR BATTERIES PRIOR TO05JUN85 THAT COMPLIES WITH 46 CFR 111.15-30.
Condition: Unknown
Due 5 May 1985
Resolved 5 May 1985
Electrical
Issued 5 May 1985 Resolved
REPAIR GOVERNOR SYNCHRONIZING MOTOR FOR PORT GENERATOR AND PROVE PROPER OPERATION UNDER FULL LOAD DURING PARALLELL OPERATION PRIOR TO 05JUN85 THAT COMPLIES WITH 46 CFR 111.12-7(A).
Condition: Unknown
Due 5 May 1985
Resolved 5 May 1985
Electrical
Issued 5 May 1985 Resolved
REPAIR LOW LUBE OIL ALARM FOR PORT GENERATOR AND TEST SAME PRIOR TO 05JUN85 AS PER 46 CFR 111.12-1(C).
Condition: Unknown
Due 5 May 1985
Resolved 5 May 1985
Unknown
Issued 5 May 1985 Resolved
THE FOLLOWING DEFICIENCIES PERTAIN TO THE VESSEL, GULF FLEET NO. 62, DN656789 AND ARE TO BE COMPLIED WITH BY 19MAY85.
Condition: Unknown
Due 5 May 1985
Resolved 5 May 1985
Deck/Cargo
Issued 5 May 1985 Resolved
INSTAL 30X30 MESH FLAME SCREENS ON ALL FUEL OIL LUBE OIL AND LIQUID MUD TANK VENTS. PRIOR TO 05JUN85 AS PER 46 CFR 56.50-85 (A)(7).
Condition: Unknown
Due 5 May 1985
Resolved 5 May 1985

Ownership record