MAURY USCG vessel records
← All vessels

SUMMER BREEZE

SUMMER BREEZE is a 1983 passenger vessel (inspected). The Coast Guard has recorded 23 inspections since 2016, most recently in March 2026, along with 25 deficiencies and 1 casualty investigation in 2011.

Records from 2011 to 2026. Most recent: inspection, 18 March 2026.

Built
1983
Last inspected
18 March 2026
Documentation
Valid · documentation file of 10 August 2026
Controls
None recorded without a removal date

Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 2016.

Inspection record

Last inspected 18 March 2026
Operational controls None recorded without a removal date
Years with a record 11 calendar years (2016–2026)
Every line above is a count of records the US Coast Guard wrote, or a date it recorded. A blank resolution means none was recorded in this data; it does not establish that a deficiency is outstanding. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Identity

WDM9975
Flag
UNITED STATES
Maury page id
psix-54885

Documentation record

Registered dimensions (L × B × D)55.0 ft × 18.0 ft × 7.8 ft
Registered tonnagegross 54 / net 43
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderRESMONDO BOAT WORKS · PERDIDO BEACH, AL, UNITED STATES · built 1983
Hull materialWood
PropulsionDiesel Reduction
Hull shapeShip
Hull configurationMonohull
Hailing portORANGE BEACH, AL
Trade endorsementsCoastwise, unrestricted, Fishery
DocumentationValid · issued 13 November 2025 · expires 31 October 2026
Service, as the file records itPassenger (Inspected)
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it54 - Simplified, Gross Ton
43 - Simplified, Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 August 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
Vessel history report
Every record for this hull, in one document — $299

Every recorded inspection, 2016 to 2026 for this class, in one chronology · every deficiency, with system, dates and resolution · operational controls imposed and removed · every name this hull has been recorded under · the vessels it was inspected alongside, and when · how its record compares with hulls of similar age and size, as a fact about the population and never a judgement about this vessel.

Read one first, in full: a forty-year chronology · a hull that changed operators four times · the sparse case, shown as an example, not for sale.

This report is in development and is not for sale yet. There is no date, and nothing is charged. Leave an email and we will tell you when it exists, once.

Inspection history · 23

18 March 2026 Annual Inspection · Deficiency Check · Administrative Inspection
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 8327972
21 March 2025 Administrative Inspection · Annual Inspection
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 8097704
24 February 2025 Internal Structural Exam · Administrative Inspection · Drydock Exam
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 8083782
29 April 2024 Annual Inspection · Administrative Inspection · Deficiency Check
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 7903583
7 November 2023 Administrative Inspection · In-Service Inspection
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 7824026
19 April 2023 Deficiency Check · COI Inspection · Administrative Inspection
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 7671253
27 March 2023 Hull Examination · Drydock Exam · Administrative Inspection · Internal Structural Exam
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 7648209
9 March 2023 Plan Review "T" Boat · Administrative Inspection
Administrative · Sector Mobile · USCG Heartland District (CGD-H) · Activity 7648517
5 December 2022 Administrative Inspection
Administrative · Sector Mobile · USCG Heartland District (CGD-H) · Activity 7604284
29 April 2022 Administrative Inspection · Annual Inspection
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 7440646
3 February 2021 Annual Inspection · Drydock Exam · Administrative Inspection
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 7190192
19 May 2020 Administrative Inspection · DAPI Audit · Annual Inspection
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 6961607
18 September 2019 In-Service Inspection · Administrative Inspection
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 6814708
12 June 2019 Annual Inspection · Administrative Inspection
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 6711828
16 October 2018 Examination of Repairs · Administrative Inspection · Drydock Exam
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 6562658
22 May 2018 Deficiency Check
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 6423739
3 May 2018 Administrative Inspection
Administrative · Sector Mobile · USCG Heartland District (CGD-H) · Activity 6405843
2 March 2018 COI Inspection · Administrative Inspection · DAPI Audit
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 6364634
16 May 2017 Deficiency Check
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 6148021
20 April 2017 Administrative Inspection · Annual Inspection · DAPI Audit · Deficiency Check
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 6128769
8 March 2017 Administrative Inspection · Hull Examination · Internal Structural Exam
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 6101042
31 May 2016 Deficiency Check
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 5893111
6 April 2016 Administrative Inspection · Annual Inspection · DAPI Audit
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 5848524

Deficiency record · 25

04 - Emergency Systems › N/A - No Subsystem › Public address system
Issued 7 April 2026 Resolved
A VESSEL WITH MORE THAN ONE PASSENGER DECK AND A VESSEL WITH OVERNIGHT ACCOMMODATIONS MUST HAVE THE PUBLIC ADDRESS SYSTEM OPERABLE FROM THE OPERATING STATION. MI OBSERVED THE PUBLIC ADDRESS SYSTEM NOT FUNCTIONING. 46 CFR 184.610(c)
Action required: 17 - Rectify deficiencies prior to departure
Resolved 9 April 2026
Resolution: Repaired and conducted satisfactory test of Public Address System.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 7 April 2026 Resolved
EACH CHILD SIZE LIFE JACKET MUST BE STOWED IN A LOCATION THAT IS APPROPRIATELY MARKED AND SEPARATED FROM ADULT LIFE JACKETS. MI OBSERVED NO DIVIDER WAS PRESENT SEPARATING THE CHILD SIZE LIFE JACKETS FROM ADULT LIFE JACKETS. 46 CFR 180.78(a)(5)
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 9 April 2026
Resolution: Vessel placed a divider between the adult and children's life jackets in compartment.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 7 April 2026 Resolved
AT EACH INITIAL AND SUBSEQUENT INSPECTION FOR CERTIFICATION, THE OWNER OR MANAGING OPERATOR MUST...HAVE THE VESSEL READY FOR INSPECTION OF ITS FIRE PROTECTION EQUIPMENT, INCLUDING THE FOLLOWING: TESTING OR RENEWAL OF FLEXIBLE CONNECTIONS AND DISCHARGE HOSES ON SEMI-PORTABLE EXTINGUISHERS. MI OBSERVED THE DISCHARGE CONE WAS BROKEN OFF ON THE FIRE EXTINGUISHER LOCATED IN THE SALOON. 46 CFR 176.810(a)(6)
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 9 April 2026
Resolution: Fire Extinguisher was replaced.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 30 April 2024 Resolved
ELECTRICAL EQUIPMENT ON A VESSEL MUST BE INSTALLED AND MAINTAINED TO PROTECT PASSENGERS, CREW, OTHER PERSONS, AND THE VESSEL FROM ELECTRICAL HAZARDS, INCLUDING FIRE, CAUSED BY OR ORIGINATING IN ELECTRICAL EQUIPMENT, AND ELECTRICAL SHOCK. INSPECTOR NOTED BARE WIRES IN VICINITY OF STEERING CONSOLE ON THE BRIDGE. COVER ALL EXPOSED WIRE TERMINATIONS.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 14 May 2024
Resolved 10 May 2024
Resolution: Vessel removed dead end wires.
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 30 April 2024 Resolved
THE CONSTRUCTION AND ARRANGEMENT OF A VESSEL MUST ALLOW THE SAFE OPERATION OF THE VESSEL GIVING CONSIDERATION TO PROVISIONS FOR PROTECTION AGAINST FIRE. INSPECTOR NOTED A HOLE IN THE STARBOARD SIDE OF THE SALON BULKHEAD LEADING TO THE ENGINE ROOM, A SPACE PROTECTED BY AN INSTALLED FIRE SUPPRESSION SYSTEM. REPAIR THE HOLE.
Condition: Damaged By Earlier Event
Action required: 16 - Rectify deficiencies w/in 14 days
Due 14 May 2024
Resolved 10 May 2024
Resolution: vessel repaired hole in gunnel.
05 - Radio Communications › N/A - No Subsystem › Main installation
Issued 19 April 2023 Resolved
46 CFR 184.502 A vessel must comply with the applicable requirements for any radio and Electronic Position Indicating Radiobeacon (EPIRB) installations, including the requirements for a station license and installation certificates to be issued by the Federal Communications Commission, as set forth in 47 CFR part 80. Vessel did not have the vessel MMSI programmed into the VHF Radio. Vessel MMSI number needs to be programmed into radio.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 3 May 2023
Resolved 8 May 2023
Resolution: Photo of MMSI number programed provided.
07 - Fire Safety › N/A - No Subsystem › Fire detection and alarm system
Issued 19 April 2023 Resolved
46 CFR 181.450 (a) (2) An interconnected detection and alarm system must be installed such that the actuation of alarm in one area results in both audible and visual alarms in all areas required by 46 CFR 181.405(c) or 118.400(d) to be protected by the interconnected detection and alarm system. Vessel's fire detection system was not interconnected. Vessel needs new interconnected fire detectors.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 3 May 2023
Resolved 8 May 2023
Resolution: Conducted FaceTime call with vessel rep. Verified system location and function.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Auxiliary engine
Issued 19 April 2023 Resolved
46 CFR 183.10-5 (f) (2) Generators and motors designed for 40 degrees Celsius may be used in 50 degrees Celsius ambient locations provided the machines are derated to 80 percent of the full load rating, and the rating or setting of the over current devices is reduced accordingly. An additional nameplate specifying the derated capacity shall be provided for each such motor and generator. Vessel's generator was designed for 40 degrees Celsius, but did not have a derated capacity nameplate. Vessel's generator needs to be derated to 80% and needs a nameplate stating the generator has been derated 80%.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 8 May 2023
Resolution: Picture of derated nameplate.
01 - Certificates & Documentation › 011 - Ships Certificates › Cargo Ship Safety Radio (including exemption)
Issued 19 May 2022 Resolved
Licensees of radio stations are required to have a current station license. Vessel's radio station telephony license is expired. Renew station license.
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Due 2 June 2022
Resolved 23 May 2022
Resolution: Received documentary evidence of required FCC paperwork.
Lifesaving › Lifebuoys › Markings (ship name/port)
Issued 19 April 2018 Resolved
Life ring needs replaced due to showing discolor and lines worn. 46CFR180.70
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 19 May 2018
Resolved 22 May 2018
Resolution: Purchased a new life ring
Lifesaving › Hand Flares › Storage
Issued 19 April 2018 Resolved
Flares improper stowage container, needs proper container 46CFR180.68
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 19 May 2018
Resolved 22 May 2018
Resolution: CG M/I went onboard to verify the CAPT has proper stowage container for all the flares.
Fire Fighting › Fixed Fire Detection System › UL 217 Approval
Issued 19 April 2018 Resolved
Portable smoke alarm is stuck on, replace with new UL217.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 19 May 2018
Resolved 22 May 2018
Resolution: CG MI verified proper portable smoke alarm was replaced.
Engineering › Gasoline Engine (auxiliary) › Exhaust Piping (4 cycle)
Issued 19 April 2018 Resolved
Generator exhaust needs one hanger added near steering due to rubbing that may cause leak. 46CFR183.200
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 19 May 2018
Resolved 22 May 2018
Resolution: CG MI went onboard to verify a hanger was installed near steering on the generator exhaust
Communications › Radio Communications › VHF Radiotelephone
Issued 19 April 2018 Resolved
Input MMSI number to the VHF radio on bridge. 47CFR80.1069
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 19 May 2018
Resolved 22 May 2018
Resolution: CG MI went onboard to verify MMSI number was entered into the VHF radio
Lifesaving › Lifefloat › Lifeline
Issued 20 April 2017 Resolved
Mount quick release link correctly for life float IAW 46 CFR 180.130
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 20 May 2017
Resolved 16 May 2017
Resolution: Quick release for life float was properly mounted.
Navigation › Piloting/Steering › Marine Charts
Issued 20 April 2017 Resolved
Purchase updated charts for area of operation IAW 46 CFR 184.420
Condition: Invalid
Action required: 705 - Other - as specified
Due 20 May 2017
Resolved 16 May 2017
Resolution: Updated charts were found on board.
Engineering › Diesel Engine (propulsion-reduction gear) › Valve
Issued 20 April 2017 Resolved
Adjust starboard side fuel shut off valve IAW 46 CFR 182.455
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 20 May 2017
Resolved 16 May 2017
Resolution: Starboard side fuel shut off was adjusted and is fully operational.
Construction/Loadline › Hull › Hull Plating
Issued 4 April 2017 Resolved
Various areas in engine room needed angel hair removed and further inspection will be required to see if any boards, bulkhead panels or stiffeneers need replaced. Owner has advised CG that he intends to CFLEX his hull in September of this year. When this happens all areas of concern will be addressed during the application of CFLEX. All areas will be cleaned-insp for structural integrity.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 1 October 2017
Resolved 20 April 2017
Resolution: Further inspection of area's performed and no further repairs needed at this time.
Operations/Management › Drug and Alcohol Testing › Proof of Enrollment
Issued 20 April 2016 Resolved
DAPI letter for all crew members on consortium letter.
Condition: Invalid
Action required: 705 - Other - as specified
Due 20 May 2016
Resolved 20 May 2016
Resolution: Vessel owner no longer employs extra deckhand that was not on the letter.
Fire Fighting › Miscellaneous Items › Waste Receptacles
Issued 20 April 2016 Resolved
Non combustible trash can needs to be on board.
Condition: Invalid
Action required: 705 - Other - as specified
Due 20 May 2016
Resolved 31 May 2016
Resolution: Vessel owner replaced all trash cans with metal cans.
Fire Fighting › Fixed Fire Detection System › Smoke Detectors
Issued 20 April 2016 Resolved
Smoke detectors needed in accommodation spaces.
Condition: Invalid
Action required: 705 - Other - as specified
Due 20 May 2016
Resolved 31 May 2016
Resolution: Vessel owner added approved smoke detectors.
Engineering › Fuel Oil Storage/Transfer System › Valve
Issued 20 April 2016 Resolved
Label fuel shutoff valves with directions for open and closed.
Condition: Invalid
Action required: 705 - Other - as specified
Due 20 May 2016
Resolved 31 May 2016
Resolution: Shut off valves were labeled.
Electrical › Electrical Distribution System (service) › Wiring
Issued 20 April 2016 Resolved
Dead-ended wires found in machinery space in forward port side of ENG room.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 20 May 2016
Resolved 31 May 2016
Resolution: Owner removed dead ended wires.
Documentation › Certificates/Documents › FCC SSL
Issued 20 April 2016 Resolved
Require new safety certificate for newly installed radio.
Condition: Invalid
Action required: 705 - Other - as specified
Due 20 May 2016
Resolved 31 May 2016
Resolution: Owner had new cert.
Accommodation/Occupational Safety › Occupational Safety › Guards for Exposed Hazards
Issued 20 April 2016 Resolved
Add guard for port ENG
Condition: Invalid
Action required: 705 - Other - as specified
Due 20 May 2016
Resolved 31 May 2016
Resolution: Owner added guard to port engine.

Casualty record · 1

3 August 2011Routine · role: Involved in a Marine Casualty · serious marine incident, as classified · 1 injured · activity 4110089
Each line is an incident investigation the Coast Guard recorded with this hull among the vessels involved, with the date and the classification the Coast Guard gave it. Involvement is not fault. The investigation narrative is not published. Source: IIR, through 2026.

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.