Records from 1983 to 2008. Most recent: inspection, 27 May 2008.
A report is not offered for this hull: Its record holds only 2 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. Reports.
Inspection history · 46
27 May 2008
Administrative Inspection
Administrative · Sector Mobile · USCG Heartland District (CGD-H) · Activity 3219362
23 April 2007
Annual Inspection
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 2905159
16 March 2007
Hull Examination · Deficiency Check · Internal Structural Exam
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 2889132
7 March 2007
Hull Examination · Internal Structural Exam
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 2883459
29 March 2006
COI Inspection
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 2611803
21 March 2005
Annual Inspection · Deficiency Check
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 2315810
25 January 2005
Hull Examination
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 2280754
12 April 2004
Annual Inspection
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 2024898
4 April 2003
Annual Inspection
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1767473
27 February 2003
Type not recorded
No type recorded · Station Gulfport · USCG Heartland District (CGD-H) · Activity 1750602
12 February 2003
Hull Examination
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1741273
11 April 2002
Annual Inspection
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1494721
21 March 2001
COI Inspection
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1060185
21 March 2001
Hull Examination
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1448209
27 July 2000
Type not recorded
No type recorded · CGC POINT ESTERO · USCG Heartland District (CGD-H) · Activity 1515689
5 April 2000
Re-Inspection
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 818403
31 March 1999
Deficiency Check
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1121207
11 March 1999
Re-Inspection
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1365116
11 February 1999
Hull Examination
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1390933
8 January 1999
Plan Review "T" Boat
Administrative · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1042807
13 April 1998
COI Inspection
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1427529
15 April 1997
Type not recorded
No type recorded · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1099664
3 April 1997
Deficiency Check
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1098260
3 March 1997
Hull Examination · Re-Inspection
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1452257
11 March 1996
Re-Inspection
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1425709
17 March 1995
COI Inspection
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1412758
9 February 1995
Hull Examination
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1460769
26 April 1994
Re-Inspection
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1168956
3 February 1994
Hull Examination
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 853545
15 April 1993
Re-Inspection
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 840763
29 January 1993
Hull Examination
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 840156
23 March 1992
COI Inspection
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1257745
10 February 1992
Hull Examination
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 946412
10 February 1992
Hull Examination
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 962403
4 March 1991
Re-Inspection
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 936484
13 February 1991
Hull Examination
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1224999
23 January 1990
Hull Examination · Re-Inspection
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 902289
27 February 1989
COI Inspection
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1198637
7 December 1988
Hull Examination
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 898171
6 April 1988
Hull Examination · Re-Inspection
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1337992
23 April 1987
Hull Examination · Re-Inspection
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1323637
16 January 1987
Examination of Repairs
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1317289
3 March 1986
COI Inspection · Credit Drydock
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 992501
1 March 1985
Type not recorded
No type recorded · MSO Mobile · USCG Heartland District (CGD-H) · Activity 980878
27 March 1984
Type not recorded
No type recorded · MSO Mobile · USCG Heartland District (CGD-H) · Activity 973951
18 April 1983
Type not recorded
No type recorded · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1276946
Personnel › Manning/Qualifications › Medical Fitness
Issued 23 April 2007
Resolved
Provide proof that master and deckhand are enrolled in a drug and alcohol program as required by 46 CFR 16
Action required: 705 - Other - as specified
Due 23 May 2007
Resolved 26 April 2007
Resolution: Provided proof that master and deckhand are enrolled in a drug and alcohol program
Fire Fighting › Means of Escape › Blocked
Issued 23 April 2007
Resolved
Prove operation of emergency exit as required by 46 CFR 177.500
Action required: 705 - Other - as specified
Due 23 May 2007
Resolved 26 April 2007
Resolution: Proved operation of emergency exit
Lifesaving › Lifefloat › Painter
Issued 23 April 2007
Resolved
Properly attach the painter line as required by 46 CFR 180.137
Action required: 705 - Other - as specified
Due 23 May 2007
Resolved 26 April 2007
Resolution: Properly attached the painter line
Lifesaving › Lifejacket/PFD (Type I) › Condition
Issued 23 April 2007
Resolved
Provide one adult lifejacket as required by 46 CFR 180.71
Action required: 705 - Other - as specified
Due 23 May 2007
Resolved 26 April 2007
Resolution: Provided one adult lifejacket
Lifesaving › Lifebuoys › Self-igniting Lights
Issued 23 April 2007
Resolved
Provide a waterlight for the ring lifebuoy as required by 46 CFR 180.70
Action required: 705 - Other - as specified
Due 23 May 2007
Resolved 26 April 2007
Resolution: Provided a waterlight for the ring lifebuoy
Fire Fighting › Portable Dry Chemical Fire Extinguisher › Service
Issued 23 April 2007
Resolved
Provide a BI class fire extinguisher at the operating station as required by 46 CFR 181.500
Action required: 705 - Other - as specified
Due 23 May 2007
Resolved 26 April 2007
Resolution: Provided a BI class fire extinguisher at the operating station
Engineering › Diesel Engine (propulsion-reduction gear) › Gear/Clutch Starter (electric)
Issued 23 April 2007
Resolved
Prove operation of the starboard engine starter as required by 46 CFR 176.404
Action required: 705 - Other - as specified
Due 23 May 2007
Resolved 26 April 2007
Resolution: Proved operation of the starboard engine starter
Engineering › Fuel Oil Service System › Hose
Issued 23 April 2007
Resolved
Double hose clamp all fuel lines on the generator as required by 46 CFR 182.410
Action required: 705 - Other - as specified
Due 23 May 2007
Resolved 26 April 2007
Resolution: Double hose clamped all fuel lines on the generator
Engineering › Fuel Oil Service System › Piping
Issued 23 April 2007
Resolved
Properly support the return fuel line on generator as required by 46 CFR 182.45
Action required: 705 - Other - as specified
Due 23 May 2007
Resolved 26 April 2007
Resolution: Properly supported the return fuel line on generator
Accommodation/Occupational Safety › Occupational Safety › Guards for Exposed Hazards
Issued 23 April 2007
Resolved
Properly attach the loose machinery guard on the generator as required by 46 CFR 177.960
Action required: 705 - Other - as specified
Due 23 May 2007
Resolved 26 April 2007
Resolution: Properly attached the loose machinery guard on the generator
Engineering › Bilge Water Management System › Piping
Issued 23 April 2007
Resolved
Prove opertion of the portable bilge pump as required by 46 CFR 182.520
Action required: 705 - Other - as specified
Due 23 May 2007
Resolved 26 April 2007
Resolution: Proved opertion of the portable bilge pump
Electrical › Electrical Distribution System (service) › Circuit Breaker
Issued 23 April 2007
Resolved
Replace the main breaker with a 30 amp or less breaker as reuired by 46 CFR 183.320
Action required: 705 - Other - as specified
Due 23 May 2007
Resolved 26 April 2007
Resolution: Replaced the main breaker with a 30 amp or less breaker
Electrical › Electrical Distribution System (service) › Junction Box
Issued 23 April 2007
Resolved
Replace the first junction box off the generator as required by 46 CFR 183.340
Action required: 705 - Other - as specified
Due 23 May 2007
Resolved 26 April 2007
Resolution: Replaced the first junction box off the generator
Engineering › Fuel Oil Service System › Filter
Issued 23 April 2007
Resolved
Make proper repairs to the port main engine fuel filter as required by 46 CFR 182.455
Action required: 705 - Other - as specified
Due 23 May 2007
Resolved 26 April 2007
Resolution: Made proper repairs to the port main engine fuel filter
Engineering › Shafting/Propeller Arrangements › Propeller (fixed pitch)
Issued 8 March 2007
Resolved
Make both propellers ready for inspection in way of cleaning and removing growth in accordance with 46 CFR 176.610.
Action required: 705 - Other - as specified
Due 8 April 2007
Resolved 20 March 2007
Resolution: Made both propellers ready for inspection in way of cleaning and removing growth in accordance with 46 CFR 176.610.
Engineering › Sea-water System (primary cooling) › Valve
Issued 8 March 2007
Resolved
Prove proper operation of the sea valve for the generator in accordance with 46 CFR 176.610.
Action required: 705 - Other - as specified
Due 8 April 2007
Resolved 20 March 2007
Resolution: Proved proper operation of the sea valve for the generator in accordance with 46 CFR 176.610.
Engineering › Steering Gear System › Rudder
Issued 8 March 2007
Resolved
Make proper repairs to both rudders in way of eliminating excessive play in accordance with 46 CFR 182.600.
Action required: 705 - Other - as specified
Due 8 April 2007
Resolved 20 March 2007
Resolution: Made proper repairs to both rudders in way of eliminating excessive play in accordance with 46 CFR 182.600.
Accommodation/Occupational Safety › Occupational Safety › Deck Rail
Issued 8 March 2007
Resolved
Properly secure handrails in accordance with 46 CFR 177.900.
Action required: 705 - Other - as specified
Due 8 April 2007
Resolved 20 March 2007
Resolution: Properly secured handrails in accordance with 46 CFR 177.900.
Electrical › Electrical Distribution System (service) › Wiring
Issued 2 May 2006
Resolved
Properly support wiring in accommodation space in accordance with 46 CFR 183.340.
Action required: 705 - Other - as specified
Due 2 June 2006
Resolved 16 May 2006
Resolution: Properly supported wiring in accommodation space in accordance with 46 CFR 183.340.
Electrical › Electric Generation Source (service) › Metallic Enclosure/Frame
Issued 2 May 2006
Resolved
Provide cover for hole in top of generator/shore power transfer box in accordance with 46 CFR 183.220.
Action required: 705 - Other - as specified
Due 2 June 2006
Resolved 16 May 2006
Resolution: Provided cover for hole in top of generator/shore power transfer box in accordance with 46 CFR 183.220.
Accommodation/Occupational Safety › Occupational Safety › Portable Electric Equipment/Appliances
Issued 2 May 2006
Resolved
Secure microwave to keep from shifting in accordance with 46 CFR 177.800.
Action required: 705 - Other - as specified
Due 2 June 2006
Resolved 16 May 2006
Resolution: Secured microwave to keep from shifting in accordance with 46 CFR 177.800.
Fire Fighting › Combustible Materials › Paints/Varnishes/Other Finishes
Issued 2 May 2006
Resolved
Remove all flammable materials from accommodation space in accordance with 46 CFR 177.800.
Action required: 705 - Other - as specified
Due 2 June 2006
Resolved 16 May 2006
Resolution: Removed all flammable materials from accommodation space in accordance with 46 CFR 177.800.
Accommodation/Occupational Safety › Occupational Safety › Deck Rail
Issued 2 May 2006
Resolved
Tighten all rail courses in accordance with 46CFR177.900.
Action required: 705 - Other - as specified
Due 2 June 2006
Resolved 16 May 2006
Resolution: Tightened all rail courses in accordance with 46 177.900.
Navigation › Collision/Grounding Avoidance › Navigation Lights
Issued 2 May 2006
Resolved
Provide proper marine grade bulb for anchor light in accordance with 72 COLREGS.
Action required: 705 - Other - as specified
Due 2 June 2006
Resolved 16 May 2006
Resolution: Provided proper marine grade bulb for anchor light in accordance with 72 COLREGS.
Construction/Loadline › Structures › Deck Plating
Issued 2 May 2006
Resolved
Repair cracking in fiberglass deck, starboard side to the right of the ladder in notch.
Action required: 705 - Other - as specified
Due 2 June 2006
Resolved 16 May 2006
Resolution: Repaired cracking in fiberglass deck, starboard side to the right of the ladder in notch.
Lifesaving › Lifebuoys › Approval
Issued 2 May 2006
Resolved
Replace retrotape on lifering in accordance with 46 CFR 180.70.
Action required: 705 - Other - as specified
Due 2 June 2006
Resolved 16 May 2006
Resolution: Replaced retrotape on lifering in accordance with 46 CFR 180.70.
Engineering › Bilge Water Management System › Interface Detector
Issued 2 May 2006
Resolved
Label bilge pump indicator light in accordance with 46 CFR 182.500.
Action required: 705 - Other - as specified
Due 2 June 2006
Resolved 16 May 2006
Resolution: Labeled bilge pump indicator light in accordance with 46 CFR 182.500.
Fire Fighting › Means of Escape › Handrails/Handholds
Issued 2 May 2006
Resolved
Provide proper emergency escape ladder in accordance with 46 CFR 177.500.
Action required: 705 - Other - as specified
Due 2 June 2006
Resolved 16 May 2006
Resolution: Provided proper emergency escape ladder in accordance with 46 CFR 177.500.
Lifesaving › Lifefloat › Markings
Issued 2 May 2006
Resolved
Provide one 12-man lifefloat with proper markings in accordance with 46 CFR 180.200 and 185.604.
Action required: 705 - Other - as specified
Due 2 June 2006
Resolved 16 May 2006
Resolution: Provided one 12-man lifefloat with proper markings in accordance with 46 CFR 180.200 and 185.604.
Lifesaving › Lifefloat › Paddle
Issued 2 May 2006
Resolved
Provide two paddles, properly marked and tethered to lifefloat in accordance with 46 CFR 180.200 and 185.604.
Action required: 705 - Other - as specified
Due 2 June 2006
Resolved 16 May 2006
Resolution: Provided two paddles, properly marked and tethered to lifefloat in accordance with 46 CFR 180.200 and 185.604.
Lifesaving › Buoyant Apparatus › Retroreflective Material
Issued 2 May 2006
Resolved
Provide new retro tape on remaining buoyant apparatus in acordance with 46 CFR 180.200.
Action required: 705 - Other - as specified
Due 2 June 2006
Resolved 16 May 2006
Resolution: Provided new retro tape on remaining buoyant apparatus in acordance with 46 CFR 180.200.
Electrical › Electrical Distribution System (service) › Wiring
Issued 2 May 2006
Resolved
Properly support wiring under operating station in accordance with 46 CFR 183.340.
Action required: 705 - Other - as specified
Due 2 June 2006
Resolved 16 May 2006
Resolution: Properly supported wiring under operating station in accordance with 46 CFR 183.340.
Accommodation/Occupational Safety › Occupational Safety › Deck Rail
Issued 2 May 2006
Resolved
Ensure all deck rails are able to withstand a point load of 200 pounds in accordance with 46 CFR 177.900.
Action required: 705 - Other - as specified
Due 2 June 2006
Resolved 16 May 2006
Resolution: Ensured all deck rails are able to withstand a point load of 200 pounds in accordance with 46 CFR 177.900.
Accommodation/Occupational Safety › Occupational Safety › Guards for Exposed Hazards
Issued 2 May 2006
Resolved
Install guards on all rotating machinery in accordance with 46 CFR 177.960.
Action required: 705 - Other - as specified
Due 2 June 2006
Resolved 16 May 2006
Resolution: Installed guards on all rotating machinery in accordance with 46 CFR 177.960.
Electrical › Electric Supply System (service) › Battery Conductor
Issued 2 May 2006
Resolved
Remove corrosion from all battery terminals in accordance with 46 CFR 183.220.
Action required: 705 - Other - as specified
Due 2 June 2006
Resolved 16 May 2006
Resolution: Removed corrosion from all battery terminals in accordance with 46 CFR 183.220.
Engineering › Bilge Water Management System › Hose
Issued 2 May 2006
Resolved
Double clamp all hoses for vital systems piping in accordance with 46 CFR 182.700.
Action required: 705 - Other - as specified
Due 2 June 2006
Resolved 16 May 2006
Resolution: Double clamped all hoses for vital systems piping in accordance with 46 CFR 182.700.
Engineering › Steering Gear System › Bracket/Clamp
Issued 2 May 2006
Resolved
Double clamp starboard shaft log in accordance with 46 CFR 182.700.
Action required: 705 - Other - as specified
Due 2 June 2006
Resolved 16 May 2006
Resolution: Double clamped starboard shaft log in accordance with 46 CFR 182.700.
Engineering › Generator (propulsion-electric) › Wiring
Issued 2 May 2006
Resolved
Properly support generator exhaust hose in accordance with 46 CFR 182.425.
Action required: 705 - Other - as specified
Due 2 June 2006
Resolved 16 May 2006
Resolution: Properly supported generator exhaust hose in accordance with 46 CFR 182.425.
Engineering › Fuel Oil Storage/Transfer System › Hose
Issued 2 May 2006
Resolved
Properly support engine fuel supply lines in accordance with 46 CFR 182.455.
Action required: 705 - Other - as specified
Due 2 June 2006
Resolved 16 May 2006
Resolution: Properly supported engine fuel supply lines in accordance with 46 CFR 182.455.
Electrical › Electrical Distribution System (service) › Wiring
Issued 2 May 2006
Resolved
Properly support all wiring in the engine room in accordance with 46 CFR 183.340.
Action required: 705 - Other - as specified
Due 2 June 2006
Resolved 16 May 2006
Resolution: Properly supported all wiring in the engine room in accordance with 46 CFR 183.340.
Electrical › Electric Generation Source (service) › Switch
Issued 2 May 2006
Resolved
Provide face plates for light switches and outlet recepticles in vicinity of engine room ladder in accordance with 46 CFR 183.220.
Action required: 705 - Other - as specified
Due 2 June 2006
Resolved 16 May 2006
Resolution: Provided face plates for light switches and outlet recepticles in vicinity of engine room ladder in accordance with 46 CFR 183.220.
Fire Fighting › Remote Fuel Shutoff › General
Issued 2 May 2006
Resolved
Provide a second means for fuel shutoff for port and starboard engine and generator, next to the engine in accordance with 46 CFR 182.455.
Action required: 705 - Other - as specified
Due 2 June 2006
Resolved 16 May 2006
Resolution: Provided a second means for fuel shutoff for port and starboard engine and generator, next to the engine in accordance with 46 CFR 182.455.
Engineering › Generator (propulsion/auxiliary-electric) › Winding
Issued 2 May 2006
Resolved
Remove oil from generator windings in accordance with 46 CFR 176.830.
Action required: 705 - Other - as specified
Due 2 June 2006
Resolved 16 May 2006
Resolution: Removed oil from generator windings in accordance with 46 CFR 176.830.
Accommodation/Occupational Safety › Occupational Safety › Deck Rail
Issued 2 May 2006
Resolved
Repair rail cap, starboard side, just aft of bow spirit in accordance with 46 CFR 177.900.
Action required: 705 - Other - as specified
Due 2 June 2006
Resolved 16 May 2006
Resolution: Repaired rail cap, starboard side, just aft of bow spirit in accordance with 46 CFR 177.900.
Operations/Management › Bilge/Bilge System Management › Control of Oil Mixtures
Issued 2 May 2006
Resolved
Remove excess oil from bilges in accordance with 46 CFR 176.830.
Action required: 705 - Other - as specified
Due 2 June 2006
Resolved 16 May 2006
Resolution: Removed excell oil from bilges in accordance with 46 CFR 176.830.
Documentation › Logs/Records › Logbook (official)
Issued 2 May 2006
Resolved
Provide professional training log book, bridge log and lifesaving equipment maintenance log in accordance with 46 CFR 185.420 and 185.702.
Action required: 705 - Other - as specified
Due 2 June 2006
Resolved 16 May 2006
Resolution: Provided professional training log book, bridge log and lifesaving equipment maintenance log in accordance with 46 CFR 185.420 and 185.702.
Documentation › Markings/Placards › Oil Discharge Placard
Issued 2 May 2006
Resolved
Provide oil pollution placard in accordance with 33 CFR 155.450.
Action required: 705 - Other - as specified
Due 2 June 2006
Resolved 16 May 2006
Resolution: Provided oil pollution placard in accordance with 33 CFR 155.450.
Navigation › Piloting/Steering › US Coast Pilot
Issued 2 March 2005
Resolved
Provide current US Coast Pilot IAW 46 CFR 184.420
Action required: 705 - Other - as specified
Due 2 April 2005
Resolved 18 March 2005
Resolution: Current Coast Pilot was provided.
Lifesaving › Lifebuoys › Markings (ship name/port)
Issued 2 March 2005
Resolved
Mark vessel's name on lifebuoy IAW 46 CFR 185.604
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 18 March 2005
Resolution: Vessel''s name was marked on life ring.
Engineering › Steering Gear System › Fastener
Issued 2 March 2005
Resolved
Provide appropriate size bushings were hydraulic arm attaches to rudder arm IAW 46 CFR 182.600
Action required: 705 - Other - as specified
Due 2 April 2005
Resolved 18 March 2005
Resolution: Appropriate bushing was installed.
Engineering › Fuel Oil Service System › Vent Pipe
Issued 2 March 2005
Resolved
Provide 30 X 30 mesh screen for fuel tank vent IAW 46 CFR 182.450 (e)
Action required: 705 - Other - as specified
Due 2 April 2005
Resolved 18 March 2005
Resolution: Mesh screen was provided.
Communications › Alarms/Indicators › Bilge Alarm
Issued 2 March 2005
Resolved
Provide visual indicator for bilge pumps at operating station IAW 46 CFR 182.530 (c)
Action required: 705 - Other - as specified
Due 2 April 2005
Resolved 18 March 2005
Resolution: Visual indicators were provided
Documentation › Certificates/Documents › FCC SSL
Issued 2 March 2005
Resolved
Provide valid FCC station license IAW 47 CFR 80
Action required: 705 - Other - as specified
Due 2 April 2005
Resolved 18 March 2005
Resolution: FCC station license was provided.
Fire Fighting › Ventilation Systems › Duct Hatches
Issued 2 March 2005
Resolved
Provide closure devices for engine room ventilation in case of fire IAW 46 CFR 182.465
Action required: 705 - Other - as specified
Due 2 April 2005
Resolved 18 March 2005
Resolution: Ventilation closure devices were provided.
Construction/Loadline › Penetrations › Bottom Plug
Issued 1 February 2005
Resolved
Repair area of delamination around keel drain IAW NVIC 8-87.
Action required: 705 - Other - as specified
Resolved 14 February 2005
Resolution: Area was grinded and repaired w/ layer of mat.
Engineering › Steering Gear System › Rudder Stock
Issued 1 February 2005
Resolved
Tighten rudders to prevent steering related casualty.
Action required: 705 - Other - as specified
Resolved 14 February 2005
Resolution: Rudders were tightened.
Deck/Cargo › Holds/Tanks › Hatch Cover
Issued 25 January 2005
Resolved
Replace gasket to watertight hatch going to compartment forward of collision bulkhead IAW 46 CFR 179.360
Action required: 705 - Other - as specified
Resolved 14 February 2005
Resolution: Gasket was replaced.
Stability › Watertight Integrity › General
Issued 25 January 2005
Resolved
Repair bilge pipe penetration in collision bulkhead.
Action required: 705 - Other - as specified
Resolved 14 February 2005
Resolution: Operator reglassed area around penetration, securing piping and retaining watertight integrity.
Lifesaving › Buoyant Apparatus
Issued 12 April 2004
Resolved
Replace rotted painter line and connect to the lifefloat. 46 CFR 180.200
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 12 April 2004
Resolution: Painter line replaced and connected to the vessel.
Navigation › Collision/Grounding Avoidance
Issued 12 April 2004
Resolved
Demonstrate proper operation of the anchor lights. 46 CFR 183..420 LEGACY COMPONENT DESC: Navigation Lights
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 12 April 2004
Resolution: Light replaced and operationally tested with satisfactory results.
Communications › Radio Communications
Issued 12 April 2004
Resolved
Provide emergency broadcast placard at the operation station per 46 CFR 184.506. LEGACY COMPONENT DESC: VHF Radiotelephone
Due 12 May 2004
Resolved 12 April 2004
Resolution: Emergency broadcast placard provided.
Electrical
Issued 11 March 1999
Resolved
Replace starboard running light as required by 46 CFR 183.420.
Condition: Unknown
Due 11 April 1999
Resolved 6 April 1999
Electrical
Issued 11 March 1999
Resolved
Remove dead ended wiring from engine room as required by 46 CFR 183.10-20.
Condition: Unknown
Due 11 April 1999
Resolved 6 April 1999
Electrical
Issued 11 March 1999
Resolved
Provide proper battery box for generator as required by 46 CFR 183.05-20.
Condition: Unknown
Due 11 April 1999
Resolved 6 April 1999
Fire Fighting
Issued 11 March 1999
Resolved
Provide proper installation of a fixed fire-fighting system as required by 46 CFR 181.400/420.
Condition: Unknown
Due 11 April 1999
Resolved 6 April 1999
Construction/Loadline
Issued 11 March 1999
Resolved
Provide high level bilge alarms as required by 46 CFR 181.530.
Condition: Unknown
Due 11 April 1999
Resolved 6 April 1999
Electrical
Issued 11 March 1999
Resolved
Remove cables and hydraulic lines from fixed bilge piping and provide proper support brackets.
Condition: Unknown
Due 11 March 1999
Resolved 6 April 1999
Engineering
Issued 11 March 1999
Resolved
Provide emergency fuel shut-off for s/s generator as required by 46 CFR 182.20-40.
Condition: Unknown
Due 11 April 1999
Resolved 6 April 1999
Construction/Loadline
Issued 11 March 1999
Resolved
Provide proper bilge suction strainer on lazerette bilge line as required by 46 CFR 182-25-5
Condition: Unknown
Due 11 April 1999
Resolved 6 April 1999
Lifesaving
Issued 3 March 1997
Resolved
PROVIDE AND PROPERLY INSTALL PROPER SIZE WEAK LINK IAW 46 CFR 180.137 (b).
Condition: Unknown
Due 3 March 1997
Resolved 3 March 1997
Engineering
Issued 3 March 1997
Resolved
REPAIR EXHAUST LEAK ON PORT MAIN ENGINE EXHAUST PIPE IAW 46 CFR 182.430 (b).
Condition: Unknown
Due 3 March 1997
Resolved 3 March 1997
Engineering
Issued 3 March 1997
Resolved
REMOVE PVC PIPING FROM GENERATOR EXHAUST SYSTEM IAW 46 CFR 182.430 AND ABYCP-1.
Condition: Unknown
Due 3 March 1997
Resolved 3 March 1997
Construction/Loadline
Issued 3 March 1997
Resolved
MAKE PROPER REPAIRS TO THE STBD BULKHEAD IN URINAL COMPARTMENT IN WAY OF _x001C_FIBERGLASS TIE-IN TAB'S IAW NVIC 8-87.
Condition: Unknown
Due 3 March 1997
Resolved 3 March 1997
Lifesaving
Issued 3 March 1997
Resolved
CONDUCT FIRE DRILL, MAN-OVERBOARD DRILL AND ABANDON SHIP DRILL IN THE PRESENCE OF THE ATTENDING U.S. COAST GUARD MARINE INSPECTOR IN ACCORDANCE WITH 46 CFR 185.520.
Condition: Unknown
Due 3 March 1997
Resolved 3 March 1997
Accommodation/Occupational Safety
Issued 3 March 1997
Resolved
RENEW EXISTING MARINE SANITATION DEVICE WITH AN APPROVED TYPE 2 OR TYPE 3 DEVICE IN ACCORDANCE WITH 33 CFR 159.7(b).
Condition: Unknown
Due 3 March 1997
Resolved 3 March 1997
Fire Fighting
Issued 11 March 1996
Resolved
CONDUCT REQUIRED FIRE AND ABANDON DRILLS.
Condition: Unknown
Due 25 March 1996
Resolved 4 April 1996