Records from 1984 to 1991. Most recent: inspection, 12 February 1991.
A report is not offered for this hull: Its record holds only 2 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. Reports.
Inspection history · 9
12 February 1991
Deficiency Check
Physical examination · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 909087
7 February 1991
Certificate of Compliance
Administrative · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 1219317
20 April 1987
Type not recorded
No type recorded · THE UNKNOWN UNIT · Activity 1314268
20 February 1987
Certificate of Compliance
Administrative · MIO HOUSTON · USCG Heartland District (CGD-H) · Activity 1014894
20 February 1987
Type not recorded
No type recorded · MIO HOUSTON · USCG Heartland District (CGD-H) · Activity 1323696
18 February 1987
Type not recorded
No type recorded · COTP HOUSTON · USCG Heartland District (CGD-H) · Activity 521558
26 July 1985
Type not recorded
No type recorded · COTP HOUSTON · USCG Heartland District (CGD-H) · Activity 303405
19 November 1984
Type not recorded
No type recorded · COTP HOUSTON · USCG Heartland District (CGD-H) · Activity 298995
19 November 1984
Type not recorded
No type recorded · MIO HOUSTON · USCG Heartland District (CGD-H) · Activity 976187
Deck/Cargo
Issued 12 February 1991
Resolved
REPAIR OR REPLACE #2 STARBOARD CARGO TANK SAFETY RELIEF VALVE PRIOR TO DEPARTING THE PORT OF HOUSTON._x001C_
Condition: Unknown
Due 12 February 1991
Resolved 12 February 1991
Electrical
Issued 20 February 1987
Resolved
PROVIDE FOR SHUT DOWN OF ELECTRICAL CIRCUITS WHICH ARE NOT EXPLOSION PROOF,IN IGS ROOM UPON LOSS OF OVERPRESURE (E.G. BOTH DOORS OPEN).
Condition: Unknown
Due 20 February 1987
Resolved 20 February 1987
Deck/Cargo
Issued 20 February 1987
Resolved
AT NEXT DRYDOCKING, REPAIR HIGH LEVEL ALARM, TANK NO. 1, STARBOARD SIDE; UNTIL REPAIRED, CROSS CONNECTION BETWEEN PORT AND STARBOARD SIDES OF TANK SHALL BE KEPT OPEN WHILE LOADING IN U.S. PORTS.
Condition: Unknown
Due 20 February 1987
Resolved 20 February 1987
Deck/Cargo
Issued 20 February 1987
Resolved
PRIOR TO RETURN TO A U.S. PORT PROVIDE PORTABLE FLAMMABLE GAS DETECTOR.
Condition: Unknown
Due 20 February 1987
Resolved 20 February 1987
Deck/Cargo
Issued 20 February 1987
Resolved
PRIOR TO TRANSFERRING OR CARRYING AMMONIA IN U.S. WATERS, PROVIDE DRAEGER TUBES FOR AMMONIA.
Condition: Unknown
Due 20 February 1987
Resolved 20 February 1987
Deck/Cargo
Issued 20 February 1987
Resolved
PRIOR TO DEPARTURE FROM PORT OF HOUSTON, DEMONSTRATE EMERGENCY SHUT DOWN WITH CARGO PUMPS AND COMPRESSORS ON THE LINE.
Condition: Unknown
Due 20 February 1987
Resolved 20 February 1987
Deck/Cargo
Issued 20 February 1987
Resolved
PRIOR TO CARRYING BUTYLENE IN U.S. WATERS, PROVIDE MSA CALIBRATION CURVE FOR BUTYLENE.
Condition: Unknown
Due 20 February 1987
Resolved 20 February 1987
Deck/Cargo
Issued 20 February 1987
Resolved
PRIOR TO VESSEL'S RETURN TO A U.S. PORT, PROVIDE SET OF CALIBRATION CURVES FOR AUER FIXED GAS DETECTOR.
Condition: Unknown
Due 20 February 1987
Resolved 20 February 1987
Construction/Loadline
Issued 20 February 1987
Resolved
REPAIR GASKETS AND KNIFE EDGES ON ALL AIRLOCK DOORS-MAKE DOORS GAS TIGHT. ALSO REMOVE ALL HOLD BACKS
Condition: Unknown
Due 20 February 1987
Resolved 20 February 1987
Construction/Loadline
Issued 20 February 1987
Resolved
REPAIR HOLE IN IGS ROOM OUTER AIR LOCK DOOR.
Condition: Unknown
Due 20 February 1987
Resolved 20 February 1987
Accommodation/Occupational Safety
Issued 20 February 1987
Resolved
PLUG DRAIN HOLES IN AFTER CORNERS, PORT AND STARBOARD, OF MOTOR ROOM
Condition: Unknown
Due 20 February 1987
Resolved 20 February 1987
Electrical
Issued 20 February 1987
Resolved
REPLACE MISSING GUARD ON EXPLOSION-PROOF LIGHT IN COMPRESSOR ROOM.
Condition: Unknown
Due 20 February 1987
Resolved 20 February 1987
Deck/Cargo
Issued 20 February 1987
Resolved
MAKE PERMANENT REPAIRS TO SOFT PATCH ON INERT GAS LINE AT AFT SIDE OF IGS HOUSE.
Condition: Unknown
Due 20 February 1987
Resolved 20 February 1987
Electrical
Issued 20 February 1987
Resolved
REMOVE SWITCH WHICH OVERRIDES ELECTRICAL CIRCUIT SHUT DOWN IN MOTOR ROOM
Condition: Unknown
Due 20 February 1987
Resolved 20 February 1987
Deck/Cargo
Issued 20 February 1987
Resolved
ZERO, CALIBRATE AND DEMONSTRATE OPERATION OF FIXED GAS DETECTION IN PRESENCE OF USCG MARINE INSPECTOR.
Condition: Unknown
Due 20 February 1987
Resolved 20 February 1987
Deck/Cargo
Issued 20 February 1987
Resolved
SET AND SEAL SAFETY RELIEF VALVES ON FORWARD CARGO TANKS.
Condition: Unknown
Due 20 February 1987
Resolved 20 February 1987
Deck/Cargo
Issued 20 February 1987
Resolved
REPAIR PRESSURE GAUGE PI E-230 ON BRIDGE
Condition: Unknown
Due 20 February 1987
Resolved 20 February 1987
Electrical
Issued 20 February 1987
Resolved
PROVIDE EXPLOSION PROOF LIGHTING IN PAINT LOCKER.
Condition: Unknown
Due 20 February 1987
Resolved 20 February 1987
Deck/Cargo
Issued 20 February 1987
Resolved
BLANK OFF STERN LOADING LINE AND PROVIDE CERTIFICATE THAT IT IS GAS FREE.
Condition: Unknown
Due 20 February 1987
Resolved 20 February 1987
Unknown
Issued 20 February 1987
Resolved
PROVIDE COPIES OF 46 CFR 1-40 AND 90-139.
Condition: Unknown
Due 20 February 1987
Resolved 20 February 1987
Engineering
Issued 20 February 1987
Resolved
REPAIR BUNKER VENT FLAME SCREENS.
Condition: Unknown
Due 20 February 1987
Resolved 20 February 1987
Accommodation/Occupational Safety
Issued 20 February 1987
Resolved
AT NEXT DRYDOCKING, RELOCATE IGS ROOM VENTILATION EXHAUST AT LEAST 2.4 METERS ABOVE THE WEATHER DECKS. UNTIL COMPLETED AND WHILE VESSEL IS IN US WATERS, VENTILATION CLOSURE SHALL REMAIN CLOSED AND IGS SHALL NOT BE OPERATED.
Condition: Unknown
Due 20 February 1987
Resolved 20 February 1987
Construction/Loadline
Issued 20 February 1987
Resolved
AT NEXT DRYDOCKING, MAKE ALL DOORS ON AIRLOCKS FOR MOTOR ROOMS AND IGS ROOM SELF-CLOSING. UNTIL COMPLETED AND WHILE IN U.S. WATERS, AIRLOCK DOORSSHALL BE MAINTAINED CLOSED, EXCEPT WHEN NECESSARY TO ENTER OR EXIT SPACE.
Condition: Unknown
Due 20 February 1987
Resolved 20 February 1987
Accommodation/Occupational Safety
Issued 20 February 1987
Resolved
AT NEXT DRYDOCKING, SEAL 4 IN. DIAMETER HOLES IN BULKHEAD BETWEEN AIRLOCKS AND MOTOR ROOM AND PROVIDE FORCED SUPPLY VENTILATION FOR AIRLOCKS. UNTIL COMPLETED AND WHILE IN U.S. WATERS, MOTOR ROOM AIRLOCK DOORS SHALL BE MAINTAINED CLOSED, EXCEPT WHEN NECESSARY TO ENTER OR EXIT MOTOR ROOM.
Condition: Unknown
Due 20 February 1987
Resolved 20 February 1987
Deck/Cargo
Issued 20 February 1987
Resolved
AT NEXT DRYDOCKING, REPAIR LPG CONDENSER OVERBOARD DISCHARGE AT RAISED TRUNK PENETRATION, PORT SIDE.
Condition: Unknown
Due 20 February 1987
Resolved 20 February 1987