TREASURE SEEKER

Built
1974
Last inspected
6 October 2020
Documentation
No record in the NVDC file of 10 August 2026
Controls
None recorded without a removal date

This record may be incomplete: the most recent inspection recorded for this vessel was 6 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 2016.

Inspection record

Last inspected 6 October 2020
…with no type recorded2
Operational controls None recorded without a removal date
Years with a record 5 calendar years (2016–2020)
Every line above is a count of records the US Coast Guard wrote, or a date it recorded. A blank resolution means none was recorded in this data; it does not establish that a deficiency is outstanding. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Identity

WDG8078
Flag
UNITED STATES
Maury page id
psix-54894

Documentation record

Tonnage as PSIX records it58 - Regulatory (Subpart C or D), Gross Ton
51 - Regulatory (Subpart C or D), Net Ton
This hull's Official Number is not in the NVDC file dated 10 August 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.
Professional
The full record for this vessel

Behind this panel: 11 inspections, each with its date, unit and type; 39 deficiencies with the resolution recorded against each, 2 without one; operational controls, none recorded without a removal date; no tow-unit appearances recorded; no other recorded names; no NVDC documentation record for this Official Number. Every line is a record the Coast Guard wrote; the counts above are the same counts as in the summary, and they are free.

Professional is $39 a month or $299 a year, or $19.99 a month locked for life at the founding rate, for the first 200 subscribers. It unlocks every detail section on every vessel page, fleet watch tied to your account, and ownership records on request. Already a subscriber? Sign in.

Maury does not score, rate or grade vessels, at any price.

Vessel history report
Every record for this hull, in one document — $299

Every recorded inspection, 1972 to 2026, in one chronology · every deficiency, with system, dates and resolution · operational controls imposed and removed · every name this hull has been recorded under · the vessels it was inspected alongside, and when · how its record compares with hulls of similar age and size, as a fact about the population and never a judgement about this vessel.

Read one first, in full: a forty-year chronology · a hull that changed operators four times · the sparse case, shown as an example, not for sale.

This report is in development and is not for sale yet. There is no date, and nothing is charged. Leave an email and we will tell you when it exists, once.

Inspection history · 11

6 October 2020 Drydock Exam
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 7068278
2 October 2020 Administrative Inspection
Administrative · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 7070427
3 January 2020 Type not recorded
No type recorded · Maritime Safety & Security Team Honolulu (91107) · Activity 6882512
15 August 2019 Administrative Inspection · Deficiency Check · Annual Inspection · DAPI Audit
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 6783631
1 October 2018 Internal Structural Exam · Deficiency Check · Drydock Exam · Administrative Inspection · Examination of Repairs
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 6545883
14 June 2018 Administrative Inspection · COI Inspection · Deficiency Check
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 6443438
21 February 2018 Type not recorded
No type recorded · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 6364998
20 November 2017 Administrative Inspection · Deficiency Check
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 6310543
19 September 2017 Annual Inspection · Administrative Inspection · Deficiency Check
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 6270403
3 August 2017 In-Service Inspection · Administrative Inspection
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 6237988
16 September 2016 Drydock Exam · Administrative Inspection · Deficiency Check · Annual Inspection
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 6005283

Deficiency record · 39

07 - Fire Safety › N/A - No Subsystem › Fixed fire extinguishing installation
Issued 6 October 2020 No resolution recorded
New installations of fire protection equipment on an existing vessel which are completed to the satisfaction of the cognizant Officer in Charge, Marine Inspection (OCMI) on or after March 11, 1996, must comply with the regulations of this part. Manual activation cable for Fireboy is not installed in accordance with manufacturer’s instructions. Configure according to manufacturer’s instructions.
Condition: Improper Installation
Action required: 701 - Prior to carriage of passengers/cargo
01 - Certificates & Documentation › 011 - Ships Certificates › Certificate of Inspection (COI)
Issued 2 October 2020 No resolution recorded
To maintain a valid Certificate of Inspection, you must complete your annual inspection within the periods specified in §176.500(b)(1) and your Certificate of Inspection must be endorsed. Vessel has exceeded the 3 month window from its anniversary date for an annual inspection and exceeded the required drydock date without completing required inspections. Vessel shall not carry passengers until both a credit drydock and an annual COI inspection have been satisfactory completed.
Condition: Invalid
Action required: 701 - Prior to carriage of passengers/cargo
05 - Radio Communications › N/A - No Subsystem › Satellite EPIRB 406MHz/1.6GHz
Issued 15 August 2019 Resolved
Vessel is required to ensure the EPIRB's battery is replaced after it is used, or before the date required by FCC regulations in 47 CFR part 80, whichever comes sooner. Vessel's EPIRB battery was past its expiration date. Replace battery to satisfaction of attending Coast Guard Marine Inspector. Vessel restricted to within one mile of shore.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 29 August 2019
Resolved 27 August 2019
Resolution: Verified new battery installed on EPIRB. Registration matched what was on board, all sat.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 15 August 2019 Resolved
Electrical equipment in a location normally exposed to splashing, water washdown, or other wet conditions must be dripproof. Electrical junction box underneath port aft deck speaker is exposed to the weather and allows water ingress. Provide appropriate protection from wet and corrosive environment.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 29 August 2019
Resolved 27 August 2019
Resolution: Waterproof sealant was used to protect electrical equipment exposed on deck, all sat.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 15 August 2019 Resolved
Machinery and fuel tank spaces must be separated from accommodation spaces by boundaries that prevent the passage of vapors. The starboard outermost cable penetration on the aft engine room bulkhead has a penetration that is not vapor tight. Provide a proper seal to prevent the passage of vapors.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 29 August 2019
Resolved 27 August 2019
Resolution: Fire retardant and waterproof sealand was used around cable penetration, all sat.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Railing, gangway, walkway and means for safe passage
Issued 15 August 2019 Resolved
Deck rails must be designed and constructed to withstand a point load of 200 pounds applied at any point in any direction. Deck rails on the port and starboard bow just forward of the stairs leading to the forecastle are loose. Provide proper support on all bow deck rails.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 29 August 2019
Resolved 27 August 2019
Resolution: All deck rails had been properly secured.
02 - Structural Conditions › N/A - No Subsystem › Decks - corrosion
Issued 15 August 2019 Resolved
A vessel must ensure that the material condition is satisfactory for its intended service. A portion of deck planking in the forward port side of the main deck is rotted through and no longer supports normal body weight. Repair deck planking to the satisfaction of the attending marine inspector.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 29 August 2019
Resolved 27 August 2019
Resolution: Cosmetic deck planking repair was satisfactory.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 15 August 2019 Resolved
Each life jacket must be marked with Type I retroreflective material approved in 46 CFR 164.018. Three life jackets were not marked with appropriate retroreflective material. Provide appropriate markings to the satisfaction of the attending marine inspector. Passenger count reduced to 46.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 29 August 2019
Resolved 27 August 2019
Resolution: Proper retroreflective material was provided for the remaining three lifejackets. PAX count returned to full COI ammount.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 1 October 2018 Resolved
The design, materials, and construction of mast, post, yards, booms, bowsprits, and standing rigging on a sailing vessel must be suitable for the intended service. Provide vessels last sail rigging survey.
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 24 October 2018
Resolution: adequate survey provided.
Lifesaving › Lifebuoys › Buoyant Lifeline
Issued 14 June 2018 Resolved
Remove buoyant line from one of the three ring life buoys.
Action required: 10 - Deficiency Rectified
Resolved 14 June 2018
Resolution: All 3 liferings had lines attached. Vessel removed one immediately to satisfy deficiency.
Engineering › Fuel Oil Service System › Suction Strainer
Issued 14 June 2018 Resolved
Replace flame screen bowls under both fuel strainers in engine room.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 28 June 2018
Resolved 28 June 2018
Resolution: Received photos of bowls installed as required.
Operations/Management › Drug and Alcohol Testing › Employee Coverage
Issued 19 October 2017 Resolved
Provide drug and alcohol testing program for vessel IAW 46 CFR Part 16 and 49 CFR Part 40
Condition: Invalid
Action required: 705 - Other - as specified
Due 19 November 2017
Resolved 14 December 2017
Resolution: Completed Dapi audit
Engineering › Diesel Engine (propulsion-reduction gear) › Exhaust Manifold
Issued 19 October 2017 Resolved
Repair oil leaks on main engine. Oil leaks were located were the exhaust piping connected to the engine exhaust manifolds on both sides of the engine.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 19 November 2017
Resolved 14 December 2017
Resolution: Satisfactorily repaired
Engineering › Diesel Engine (propulsion-reduction gear) › Exhaust Manifold
Issued 19 October 2017 Resolved
Replace collapsed hose provided cooling water to the STBD exhaust piping on the engine.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 19 November 2017
Resolved 14 December 2017
Resolution: Collapsed hose replaced
Fire Fighting › Fixed Halon Fire Extinguishing System › Operating Controls
Issued 19 September 2017 Resolved
Rewire preengineered fixed fire extinguishing system to include deenergizing engine room ventilation fans. Until rewiring is complete, post instructions at helm to indicate to master to manually shut ventilation off before discharge of preengineering fixed fire extinguishing system. 46 CFR 181.420(a)(3).
Condition: Invalid
Action required: 705 - Other - as specified
Due 28 September 2017
Resolved 28 September 2017
Resolution: Operationally tested fire boy system. Verified engine and ventilation shut down.
Operations/Management › Drug and Alcohol Testing › Recordkeeping
Issued 19 September 2017 Resolved
Conduct a DAPI Audit with a qualified marine inspector. Current records indicate that company's DAPI program is inadequate. 46 CFR 16.203
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 19 November 2017
Resolved 14 December 2017
Resolution: Dapi audit complete
Accommodation/Occupational Safety › Occupational Safety › Guards for Exposed Hazards
Issued 19 September 2017 Resolved
Insulate engine exhaust elbows. 46 CFR 177.970
Action required: 705 - Other - as specified
Due 19 October 2017
Resolved 19 October 2017
Resolution: Verified that exhaust elbows were wrapped with insulation. All sat.
Accommodation/Occupational Safety › Occupational Safety › Guards for Exposed Hazards
Issued 19 September 2017 Resolved
Install guards on rotating belts on main engine.
Condition: Invalid
Action required: 705 - Other - as specified
Due 19 November 2017
Resolved 20 November 2017
Resolution: Vessel rep provided pictures for machinery guards.
Engineering › Fuel Oil Storage/Transfer System › Vent Pipe
Issued 19 September 2017 Resolved
Install 30 x 30 flame screen mesh on fuel tank vent pipes. 46 CFR 182.450
Condition: Invalid
Action required: 705 - Other - as specified
Due 19 October 2017
Resolved 19 October 2017
Resolution: Verified that 30 x 30 mesh screen was installed as a flame screen on the fuel tank vent openings.
Navigation › Piloting/Steering › Tide/Tidal Current Tables
Issued 19 September 2017 Resolved
Provide tidal current tables for operating area from an approved source. 46 CFR 184.420
Action required: 705 - Other - as specified
Due 28 September 2017
Resolved 28 September 2017
Resolution: Vessel provided print out of tidal current tables for operating area.
Electrical › Electric Supply System (service) › Overcurrent Device
Issued 3 August 2017 Resolved
Ensure all fuses are UL Listed cartridge type fuses, listed to provide branch circuit protection to protect the circuit conductors. UL Listed Class CC, G, H, J, K, RK1, RK5, & T are all UL listed to protect conductors.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 20 October 2017
Resolved 19 October 2017
Resolution: Verified all blade type fuses were replaced with UL listed cartridge type fuses, listed to protect conductors. All sat.
Electrical › Electrical Distribution System (service) › Wiring
Issued 3 August 2017 Resolved
Ensure terminal connections are made with "captive type" connectors & sized appropriately.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 20 October 2017
Resolved 19 October 2017
Resolution: Verified that terminal connectors previously found to be of the wrong type, were replaced with connectors that were captive type. All sat.
Electrical › Electrical Distribution System (service) › Ground Detection
Issued 3 August 2017 Resolved
Provide required ground-detection meter to monitor current flow in the "neutral-to-hull" connection from the inverter chasis to the ship's hull.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 20 October 2017
Resolved 19 October 2017
Resolution: Verified that required ground-detection meter was installed. All sat.
Electrical › Electric Supply System (service) › Overcurrent Device
Issued 3 August 2017 Resolved
Ensure fuses installed for bow-thruster battery bank can be disconnected by a disconnect switch installed on the supply side of the fuse.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 19 September 2017
Resolved 19 September 2017
Resolution: Battery switch has been installed so that it de-energizes the supply side of the fuses as required.
Electrical › Electrical Distribution System (service) › Wiring
Issued 3 August 2017 Resolved
Provide updated DC electrical one-line diagram & DC load analysis to reflect changes made to the electrical system.
Condition: Invalid
Action required: 705 - Other - as specified
Due 19 November 2017
Resolved 13 June 2018
Resolution: Plans submitted and verified.
Electrical › Electrical Distribution System (service) › Overcurrent Device
Issued 27 September 2016 Resolved
Replace blade-type fuses located in fuel tank shut off valve compartment, located just aft of the engine room. Fuses panel is located in upper PORT side corner of the space.
Condition: Invalid
Action required: 705 - Other - as specified
Due 27 October 2016
Resolved 6 October 2016
Resolution: Vessel engineer replaced blade-type fuses with cartridge type glass-tube fuses. Requested datasheets for fuses from engineer to verify UL Listing.
Navigation › Piloting/Steering › Tide/Tidal Current Tables
Issued 27 September 2016 Resolved
Provide updated paper copies of current and tide tables
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 27 October 2016
Resolved 6 October 2016
Resolution: Verified vessel had updated tide tables
Navigation › Piloting/Steering › Coast Guard Light List
Issued 27 September 2016 Resolved
Provide updated copy of USCG Light list
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 27 October 2016
Resolved 6 October 2016
Resolution: Verified vessel had updated CG light list
Navigation › Piloting/Steering › Marine Charts
Issued 27 September 2016 Resolved
Provide current/updated charts of vessel's operating area/route
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 27 October 2016
Resolved 6 October 2016
Resolution: Verified vessel had updated/current charts
Stability › Watertight Integrity › General
Issued 27 September 2016 Resolved
Prevent cooler drain hose from penetrating E/R boundary in aft galley void and plug/seal holes in the bulkhead.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 27 October 2016
Resolved 6 October 2016
Resolution: Verified cooler drain hose penetrating E.R bulkhead was removed, and hole in E/R bulkhead was properly sealed.
Electrical › Electrical Distribution System (service) › Wiring
Issued 27 September 2016 Resolved
Complete outstanding electrical deficiencies from previous CG-835s and 2016 dry dock worklist.
Action required: 705 - Other - as specified
Due 27 October 2016
Resolved 6 October 2016
Resolution: Cleared previous outstanding deficiencies.
Construction/Loadline › Hull › Longitudinal Frame
Issued 27 September 2016 Resolved
Sister or replace 3rd overhead longitudinal wood beam in FWD galley void.
Condition: Design Flaw
Action required: 705 - Other - as specified
Due 27 October 2016
Resolved 6 October 2016
Resolution: Verified 3rd overhead longitudinal in FWD galley void had been sistered.
Construction/Loadline › Hull › Longitudinal Frame
Issued 27 September 2016 Resolved
Replace wood used to "sister" 2nd longitudinal wood frame in foward galley void.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 27 October 2016
Resolved 6 October 2016
Resolution: Verified sister member to 2nd longitudinal frame in forward galley had been replaced.
Electrical › Electrical Distribution System (service) › Wiring
Issued 27 September 2016 Resolved
Make all electrical connections/terminal strips in away of bilges "splash proof".
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 27 October 2016
Resolved 6 October 2016
Resolution: Verified terminal connections in bilge were made splash proof.
Stability › Watertight Integrity › General
Issued 27 September 2016 Resolved
Remove rust scale off of all watertight hatch sealing surfaces. Conduct fire hose test of all watertight hatches.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 27 October 2016
Resolved 6 October 2016
Resolution: Verified watertight hatch sealing surfaces were free of rust scale. Witnessed hose test, all sat
Electrical › Electrical Distribution System (service) › Circuit Breaker
Issued 27 September 2016 Resolved
Replace supplemental circuit breakers located in galley panel with circuit breakers that meet 46CFR 183.380 and UL 489.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 27 October 2016
Resolved 6 October 2016
Resolution: Vessel engineer added glass tube cartridge type fuses in-line with UL 1077 circuit breakers. Requested fuse datasheets to verify UL Listing.
Electrical › Electric Generation Source (service) › Generator
Issued 27 September 2016 Resolved
Clean excessive oil build up from alternator windings
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 27 October 2016
Resolved 6 October 2016
Resolution: Verified alternator windings had been cleaned
Lifesaving › Lifejacket/PFD (General) › Storage
Issued 27 September 2016 Resolved
Properly mark lifejacket stowage locations on forward upper deck.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 27 October 2016
Resolved 6 October 2016
Resolution: Verified stowage marking for lifejacket stowage areas.
Documentation › Markings/Placards › Lifejacket Placard
Issued 27 September 2016 Resolved
Post required lifejacket donning placards where lifejackets are stowed.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 27 October 2016
Resolved 6 October 2016
Resolution: Verified lifejacket donning placards were posted.

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.