MAURY USCG vessel records Sign in
← All vessels

PAPAGALLO II

PAPAGALLO II is a 1964 passenger vessel (inspected). The Coast Guard has recorded 81 inspections since 1984, most recently in April 2025, along with 211 deficiencies, 3 operational controls and 2 casualty investigations between 2005 and 2015.

Records from 1984 to 2025. Most recent: inspection, 24 April 2025.

Built
1964
Last inspected
24 April 2025
Documentation
Valid · documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

WDC9874
Flag
UNITED STATES
367107830 (licence lapsed)
Maury page id
psix-54895

Inspections, by type

…with no type recorded11
Years with a record 37 calendar years (1984–2025)
The 81 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 1977.

Documentation record

Registered dimensions (L × B × D)71.0 ft × 17.2 ft × 8.0 ft
Registered tonnagegross 65 / net 52
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderBURGER BOAT CO INC · MANITOWOC, WI, UNITED STATES · built 1964
Hull materialAluminum
PropulsionDiesel Reduction
Hull shapeShip
Hull configurationMonohull
Hailing portSAN FRANCISCO, CA
Trade endorsementsCoastwise, unrestricted
DocumentationValid · issued 26 November 2025 · expires 31 October 2026
Service, as the file records itPassenger (Inspected)
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it65 - Simplified, Gross Ton
52 - Simplified, Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 September 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.

Radio station licence

WDC9874MMSI 367107830 · expired · compulsorily equipped · granted 8 March 2016, cancelled 20 June 2026
WCW7239MMSI not assigned · expired · voluntarily equipped · granted 8 July 1996, cancelled 9 September 2006
FCC Universal Licensing System ship-station file of 6 September 2026, matched to this hull on its US Official Number. Status and dates are the file’s own. The licensee is not read from the file and is not shown. A lapsed licence’s MMSI is still the number the vessel transmitted under while it was valid.

Inspection history · 81

24 April 2025 Drydock Exam · Internal Structural Exam · Hull Examination · Administrative Inspection
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 8118164
12 November 2024 Annual Inspection
Physical examination · Marine Safety Detachment Santa Barbara · USCG Southwest District (CGD-SW) · Activity 8096977
27 November 2023 Deficiency Check
Physical examination · Marine Safety Detachment Santa Barbara · USCG Southwest District (CGD-SW) · Activity 7830034
24 October 2023 Annual Inspection · Administrative Inspection
Physical examination · Marine Safety Detachment Santa Barbara · USCG Southwest District (CGD-SW) · Activity 7812847
30 March 2023 Drydock Exam · Hull Examination · Deficiency Check · Internal Structural Exam
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 7658683
1 March 2023 Deficiency Check · Administrative Inspection
Physical examination · Marine Safety Detachment Santa Barbara · USCG Southwest District (CGD-SW) · Activity 7645445
17 November 2022 Deficiency Check · Administrative Inspection · Annual Inspection
Physical examination · Marine Safety Detachment Santa Barbara · USCG Southwest District (CGD-SW) · Activity 7576390
1 November 2021 Annual Inspection · Deficiency Check
Physical examination · Marine Safety Detachment Santa Barbara · USCG Southwest District (CGD-SW) · Activity 7326770
10 March 2021 Deficiency Check
Physical examination · Marine Safety Detachment Santa Barbara · USCG Southwest District (CGD-SW) · Activity 7150016
9 February 2021 Internal Structural Exam · Drydock Exam · Hull Examination
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 7135828
3 September 2020 COI Inspection
Physical examination · Marine Safety Detachment Santa Barbara · USCG Southwest District (CGD-SW) · Activity 7037519
20 November 2019 Annual Inspection · Deficiency Check
Physical examination · Marine Safety Detachment Santa Barbara · USCG Southwest District (CGD-SW) · Activity 6849186
7 August 2019 Plan Review "T" Boat
Administrative · Marine Safety Detachment Santa Barbara · USCG Southwest District (CGD-SW) · Activity 6782241
19 February 2019 Internal Structural Exam · Administrative Inspection · Drydock Exam
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 6628469
27 November 2018 Annual Inspection
Physical examination · Marine Safety Detachment Santa Barbara · USCG Southwest District (CGD-SW) · Activity 6578197
16 November 2017 Annual Inspection
Physical examination · Marine Safety Detachment Santa Barbara · USCG Southwest District (CGD-SW) · Activity 6300348
22 March 2017 Drydock Exam · Administrative Inspection · Internal Structural Exam
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 6109253
19 October 2016 Annual Inspection
Physical examination · Marine Safety Detachment Santa Barbara · USCG Southwest District (CGD-SW) · Activity 6015103
7 October 2015 Administrative Inspection · In-Service Inspection
Physical examination · Marine Safety Detachment Santa Barbara · USCG Southwest District (CGD-SW) · Activity 5738606
8 September 2015 Deficiency Check · COI Inspection
Physical examination · Marine Safety Detachment Santa Barbara · USCG Southwest District (CGD-SW) · Activity 5234399
5 September 2015 Type not recorded
No type recorded · Marine Safety Detachment Santa Barbara · USCG Southwest District (CGD-SW) · Activity 5733838
5 October 2010 DAPI Audit · COI Inspection · Deficiency Check
Physical examination · Marine Safety Detachment Santa Barbara · USCG Southwest District (CGD-SW) · Activity 3854812
24 March 2009 Deficiency Check · Hull Examination
Physical examination · Marine Safety Detachment Santa Barbara · USCG Southwest District (CGD-SW) · Activity 3439456
6 January 2009 Annual Inspection
Physical examination · Marine Safety Detachment Santa Barbara · USCG Southwest District (CGD-SW) · Activity 3389137
20 March 2008 Type not recorded
No type recorded · Station Morro Bay · USCG Southwest District (CGD-SW) · Activity 3168597
16 November 2007 Periodic Inspection
Physical examination · Marine Safety Detachment Santa Barbara · USCG Southwest District (CGD-SW) · Activity 3099627
28 March 2007 Hull Examination
Physical examination · Marine Safety Detachment Santa Barbara · USCG Southwest District (CGD-SW) · Activity 2896696
5 December 2005 Type not recorded
No type recorded · Marine Safety Detachment Santa Barbara · USCG Southwest District (CGD-SW) · Activity 2548237
6 October 2005 Administrative Inspection · COI Inspection · Deficiency Check
Physical examination · Marine Safety Detachment Santa Barbara · USCG Southwest District (CGD-SW) · Activity 2508980
10 August 2005 Administrative Inspection
Administrative · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 2465691
2 August 2005 Annual Inspection
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 2345844
21 July 2005 Hull Examination
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 2345841
12 May 2005 Liferaft Servicing
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 2356084
19 May 2004 Plan Review "T" Boat · Annual Inspection · Deficiency Check
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 2072446
14 August 2003 Deficiency Check · Plan Review "T" Boat · Annual Inspection
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1875866
9 April 2003 Hull Examination
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1757474
17 May 2002 Deficiency Check · COI Inspection
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1606261
3 July 2001 Re-Inspection
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1379502
17 April 2001 Type not recorded
No type recorded · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1062495
12 April 2001 Hull Examination
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1382174
26 May 2000 Re-Inspection
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1408525
11 January 2000 Deficiency Check
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 814281
11 January 2000 Deficiency Check
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 815139
7 December 1999 Type not recorded
No type recorded · USCGC OSPREY (WPB 87307) · USCG Northwest District (CGD-NW) · Activity 1512163
7 June 1999 Deficiency Check
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1093323
25 May 1999 COI Inspection
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1464847
15 March 1999 Hull Examination
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1395136
29 September 1998 Deficiency Check
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 802018
10 June 1998 Re-Inspection
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 798264
5 June 1997 Re-Inspection
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1447720
16 April 1997 Hull Examination
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1102545
6 June 1996 COI Inspection
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1456364
24 April 1995 Deficiency Check · Hull Examination · COI Inspection
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1400174
22 June 1994 Deficiency Check
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1023666
20 April 1994 COI Inspection
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1170448
10 May 1993 COI Inspection
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 830929
9 April 1993 Hull Examination
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 832503
12 June 1992 Deficiency Check · COI Inspection
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 956610
13 November 1991 Deficiency Check
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 945545
11 July 1991 Administrative
Administrative · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1247637
25 June 1991 COI Inspection
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 938096
18 June 1991 Hull Examination
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1197187
23 May 1990 Deficiency Check
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1219089
5 April 1990 COI Inspection · Hull Examination
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 907750
21 September 1989 Deficiency Check
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1202613
11 August 1989 Deficiency Check
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 894150
23 June 1989 Type not recorded
No type recorded · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1197008
24 April 1989 Deficiency Check · COI Inspection
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1032186
23 August 1988 Type not recorded
No type recorded · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1344672
11 May 1988 Deficiency Check
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1044223
6 May 1988 Hull Examination · COI Inspection
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1034192
26 June 1987 Administrative
Administrative · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1315482
21 April 1987 COI Inspection
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1314125
23 September 1986 Credit Drydock
Administrative · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1312324
24 April 1986 COI Inspection
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 997058
16 September 1985 Deficiency Check
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1302410
10 September 1985 Credit Drydock · Deficiency Check
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 989200
3 May 1985 Type not recorded
No type recorded · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1286196
16 April 1985 Type not recorded
No type recorded · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1292000
31 January 1985 Type not recorded
No type recorded · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 977615
16 November 1984 Type not recorded
No type recorded · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 976787

Deficiency record · 211

03 - Water/Weathertight Conditions › N/A - No Subsystem › Windows, sidescuttles and deadlights
Issued 24 April 2025 Resolved
If a vessel operates on exposed or partially protected waters, an opening port light is not permitted below the weather deck unless—(1) The sill is at least 30 inches (76.2 centimeters) above the deepest subdivision load line; and(2) It has an inside, hinged dead cover. 1.Portside forward engine room hinged dead cover for port light had a torn gasket; and 2.Starboardside aft engine room hinged dead cover for port light had a missing wing-nut for closing/watertightness. Replace both the gasket and wing-nut to the satisfaction of Marine Inspector. Due prior to credit drydock. 46 CFR 171.119(a)(2)
Action required: 705 - Other - as specified
Due 8 May 2025
Resolved 2 June 2025
Resolution: Photo evidence received showing port hole issues corrected to satisfaction of MI.
07 - Fire Safety › N/A - No Subsystem › Fire-dampers
Issued 24 October 2023 Resolved
Provision must be made for closing all supply duct cowls or scoops and exhaust duct discharge openings for a space protected by a fixed gas extinguishing system. All closure devices must be readily available and mounted in the vicinity of the vent. Port damper located in lazarette which is covered by fixed CO2 extinguishing did not close upon test actuation. Damper must be corrected prior to operation of lazarette auxiliary engine. 46 CFR 182.465(h)
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 24 November 2023
Resolved 27 November 2023
Resolution: Owner provided SAT video evidence of port damper operation.
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 24 October 2023 Resolved
Each entrance to a space storing carbon dioxide cylinders, a space protected by carbon dioxide systems, or any space into which carbon dioxide might migrate must be conspicuously marked as follows: Spaces protected by carbon dioxide—“CARBON DIOXIDE GAS CAN CAUSE INJURY OR DEATH. WHEN ALARM OPERATES OR WINTERGREEN SCENT IS DETECTED, DO NOT ENTER UNTIL VENTILATED. LOCK OUT SYSTEM WHEN SERVICING.” The reference to wintergreen scent may be omitted for carbon dioxide systems not required to have odorizing units and not equipped with such units. Markings and warnings were not provided for lazarette and machinery spaces protected by fixed CO2 extinguishing. 46 CFR 185.612(g)
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 7 November 2023
Resolved 12 December 2023
Resolution: Vessel provided evidence of warning placard installed.
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 1 March 2023 Resolved
A vessel that is exposed to salt water more than three months in any 12 month period since the last examination must undergo a dry-dock examination and an internal structural examination at least once every two years. As per her COI, vessel is currently outside compliance and can no longer operate under the conditions of her COI. The vessel may operate in the following alternative services, within the limits of the vessel’s current stability letter: (a) as a small passenger vessel, carrying 6 or less passengers without deck cargo, with one licensed master. (b) as a bareboat chartered recreational vessel carrying 12 or less passengers with no crew provided by the Owner/Operator. Vessel must undergo a satisfactory dry-docking in compliance with 46 CFR Sub-chapter T, in the presence of a USCG Marine Inspector, in order to clear this deficiency.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 9 April 2023
Resolution: Item was cleared due to hull exam being conducted in Sector San Francisco's [name withheld] (see activity 7658683):
07 - Fire Safety › N/A - No Subsystem › Fixed fire extinguishing installation
Issued 17 November 2022 Resolved
At each initial and subsequent inspection for certification, the owner or managing operator must be prepared to conduct tests and have the vessel ready for inspection of its fire protection equipment, including inspection of controls for each fixed gas fire extinguishing system and detection system to determine that the system is in operating condition. Pressure switches in E/R and lazerette were found to not have been serviced as per records provided from owner. Provide proof of satisfactory servicing of pressure switches, and inform this office what the pressure switches function are, to attending Marine Inspector.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 19 November 2022
Resolution: Provided satsifactory servicing report for pressure switches in the engine room and lazarette. Both switches shut off the fans.
05 - Radio Communications › N/A - No Subsystem › Satellite EPIRB 406MHz/1.6GHz
Issued 17 November 2022 Resolved
Each disposable hydrostatic release unit (HRU) must be marked with an expiration date of two years after the date on which the unit is installed (or as per manufacturer recommendations). HRO was marked as expired. Replace w/ properly marked HRU to manufacturer specifications. Vessel must stay within 03 miles of a harbor of safe refuge until resolved and made satisfactory to attending Marine Inspector.
Action required: 705 - Other - as specified
Resolved 4 February 2023
Resolution: Replaced w/ properly marked HRU.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 17 November 2022 Resolved
Each life jacket carried on a vessel on a coastwise route, must have a life jacket light approved in accordance with § 161.012 in subchapter Q of this chapter, or other standard specified by the Commandant, including, but not limited to, approval series 160.112. Numerous lifejacket lights were not operable. Until this deficiency is corrected, the vessel is limited to a route that does not extend more than 20 miles from a harbor of safe refuge. Vessel must make life jackets in compliance to the satisfaction of attending Marine Inspector.
Action required: 705 - Other - as specified
Resolved 2 December 2022
Resolution: Vessel made life jackets in compliance to the satisfaction of attending Marine Inspector.
11 - Life Saving Appliances › N/A - No Subsystem › Distress flares
Issued 17 November 2022 Resolved
A vessel on coastwise route must carry six hand red flare distress signals & six hand orange smoke distress signals. Six hand red flare distress signals can be substituted for six hand orange smoke distress signals. Vessel was missing 08 distress signals. Vessel is limited to short runs approximately 30 minutes away from the dock. Make number and type of distress signals as required for route on COI.
Action required: 705 - Other - as specified
Resolved 1 December 2022
Resolution: Made number and type of distress signals as required for route on COI.
18 - Maritime Labour Convention (Not Applicable to PSC Exams conducted in the U.S.) › N/A - No Subsystem › Other (Conditions of employment)
Issued 17 November 2022 Resolved
The marine employer must have a sufficient number of alcohol testing devices readily accessible on board the vessel to determine the presence of alcohol in the system of each individual who was directly involved in the SMI. Vessel's testing devices were unavailable. Until such time that valid testing devices are available onboard,vessel must stay within 2 hours of a location to perform the required alcohol tests from the time of occurrence of the SMI. Vessel will need to replace testing devices as required and or show written policy attesting to how the vessel will obtain the devices and conduct the required alcohol tests within 2 hours from the time of occurrence of the SMI.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 1 December 2022
Resolved 1 December 2022
Resolution: Vessel replaced testing devices as required.
01 - Certificates & Documentation › 011 - Ships Certificates › Cargo Ship Safety Radio (including exemption)
Issued 17 November 2022 Resolved
Each ship transporting more than six passengers for hire equipped with a radiotelephone station in accordance with Part III of Title III of the Communications Act must carry a radio operator who meets the following requirements: (1) Where the station power does not exceed 250 watts carrier power or 1500 watts peak envelope power, the radio operator must hold a marine radio operator permit or higher class license. (2) Where the station power exceeds 250 watts carrier power or 1500 watts peak envelope power, the radio operator must hold a general radiotelephone operator license or higher class license. Vessel Master/owner did not have available a Federal Communications Commission Marine Radio Operator Permit. Provide valid Federal Communications Commission Marine Radio Operator Permit.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 17 December 2022
Resolved 22 February 2023
Resolution: Provided valid Federal Communications Commission Marine Radio Operator Permit.
01 - Certificates & Documentation › 011 - Ships Certificates › Other (certificates)
Issued 17 November 2022 Resolved
The person in command of a documented vessel must have on board that vessel the original Certificate of Documentation (COD) currently in effect for that vessel. Vessel did not have valid COD on board. Provide proof of valid COD to attending Marine Inspector.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 17 December 2022
Resolved 19 December 2022
Resolution: Provided proof of valid COD to attending Marine Inspector.
09 - Working and Living Conditions › 091 - Living Conditions › Medical Equipment
Issued 17 November 2022 Resolved
The owner, charterer, master or managing operator shall instruct each crew member, at least once every three months, as to the duties that the crew member is expected to perform in an emergency including, but not limited to, the emergency instructions listed on the emergency instruction placard required by 46 CFR 185.510. Vessel was not able to produce logged drills for abandon ship and man overboard. Provide next logged drills within 30 days to attending Marine Inspector & continue as internal policy as required by the regulations.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 17 December 2022
Resolved 19 December 2022
Resolution: Provided attestation of logged drills.
09 - Working and Living Conditions › 091 - Living Conditions › Medical Equipment
Issued 17 November 2022 Resolved
A vessel must carry either a first-aid kit approved under approval series 46 CFR 160.041 or a kit with equivalent contents and instructions. Items in kit were expired/missing. Make kit in compliance with regulations.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 1 December 2022
Resolved 1 December 2022
Resolution: Made kit in compliance with regulations.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 17 November 2022 Resolved
Each ring life buoy must be marked in clearly legible block capital letters with the vessel's name. 02 required ring life buoys were not marked with the vessel's name. Have ring life buoy's marked in accordance with regulations and to the satisfaction of the attending Marine Inspector.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 1 December 2022
Resolved 1 December 2022
Resolution: Had ring life buoy marked in accordance with regulations and to the satisfaction of the attending Marine Inspector.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 17 November 2022 Resolved
The number and identification of life jackets stowed inside, and their sizes, must be marked in clearly legible letters and numbers on each container for life jackets. Letters and numbers must be at least 2 inches high. Containers for life jackets were not correctly marked. Make containers and stowage as required by regulation.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 1 December 2022
Resolved 1 December 2022
Resolution: Made containers and stowage as required by regulation.
07 - Fire Safety › N/A - No Subsystem › Fixed fire extinguishing installation
Issued 1 November 2021 Resolved
At each initial and subsequent inspection for certification, the owner or managing operator must be prepared to conduct tests and have the vessel ready for inspection of its fire protection equipment, including inspection of controls for each fixed gas fire extinguishing system and detection system to determine that the system is in operating condition. Heat activated device was found to not have been serviced as per records provided from owner. Provide proof of satisfactory servicing of heat activated device in lazerette to attending Marine Inspector.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 4 November 2021
Resolution: Provided proof of satisfactory servicing of heat activated device in lazerette to attending Marine Inspector.
11 - Life Saving Appliances › N/A - No Subsystem › Inflatable liferafts
Issued 1 November 2021 Resolved
Each disposable hydrostatic release unit (HRU) must be marked with an expiration date of two years after the date on which the unit is installed. Markings on vessels IBA HRU were non-existent or unreadable. HRU was installed upside down. Replace with properly marked/ installed HRU to manufacturer specifications. Make satisfactory to attending Marine Inspector.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 4 November 2021
Resolution: Replaced with properly marked/installed HRU to manufacturer specifications.
11 - Life Saving Appliances › N/A - No Subsystem › Inflatable liferafts
Issued 1 November 2021 Resolved
Each survival craft must be stowed so that when the vessel sinks the survival craft floats free. Float free configuration was not installed correctly on vessel IBA. Correct float free configuration to manufacturer specifications and Marine Inspector satisfaction.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 4 November 2021
Resolution: Corrected float free configuration to manufacturer specifications and Marine Inspector satisfaction.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 1 November 2021 Resolved
At least one ring life buoy must be fitted with a lifeline. Each lifeline on a ring life buoy must be buoyant; be of at least 60 feet in length; be nonkinking; have a diameter of at least 5 16 inch; have a breaking strength of at least 1,124 pounds; and be of a dark color if synthetic, or of a type certified to be resistant to deterioration from ultraviolet light. Lifeline was not fitted to ring life buoy. Fit appropriate lifeline to ring life buoy.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 15 November 2021
Resolved 6 November 2021
Resolution: Appropriate lifeline made to ring life buoy.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 1 November 2021 Resolved
A vessel must carry one floating waterlight, unless it is limited to daytime operation. Each ring life buoy with a floating waterlight must have a lanyard of at least 3 feet in length, but not more than 6 feet, securing the waterlight around the body of the ring life buoy. Vessel's waterlight was not operational and was not attached to ring life buoy. Make waterlight serviceable and attached to ring life buoy.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 15 November 2021
Resolved 12 November 2021
Resolution: Waterlight made serviceable and attached to ring life buoy.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 1 November 2021 Resolved
On a vessel of more than 65 feet in length, the minimum capacity of the fire pump must be 50 gallons per minute at a pressure of not less than 60 psi at the pump outlet. Vessel's fire pump was operating at 35 psi at the pump gauge. Make pump satisfactory to attending Marine Inspector.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 15 November 2021
Resolved 30 November 2021
Resolution: Vessel's fire pump pressure is between 30-35 PSI at the gauge affixed to the pump outlet. The intent of this regulation has been met by the vessel's ability to provide an effective stream for all spaces protected by the vessel's fire pump. See NOTE
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 1 November 2021 Resolved
All machinery and equipment must be installed and maintained in such a manner as to afford adequate protection from causing fire, machinery failure and personnel injury. Vessel's bilge pump belt was loose and began smoking. replace or repair belt to avoid hazardous conditions mentioned above.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 15 November 2021
Resolved 4 November 2021
Resolution: Belt adjusted.
10 - Safety of Navigation › N/A - No Subsystem › Charts
Issued 1 November 2021 Resolved
As appropriate for the intended voyage, a vessel must carry adequate and up-to-date charts of large enough scale to make safe navigation possible. Vessel's chart was not up-to-date. Provide current/corrected charts for operational areas.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 15 November 2021
Resolved 4 November 2021
Resolution: Vessel master attested to charts being on-board in the form of electronic overlay (Navionics).
04 - Emergency Systems › N/A - No Subsystem › Muster list
Issued 1 November 2021 Resolved
The master and crew of a vessel will be familiar with the content of and have mounted at the operating station, emergency instructions containing the actions to be taken in the event of fire, heavy weather, or man overboard conditions. Except when in the judgment of the cognizant OCMI the operation of a vessel does not present one of the hazards listed, the emergency instruction placard should contain at least the applicable portions of the “Emergency Instructions” listed in §185.512. The emergency instructions must be designed to address the particular equipment, arrangement, and operation of each individual vessel. Emergency instruction covering fire aboard vessel is not addressed. Vessel must update emergency procedures as addressed during vessel's annual inspection to address the particular equipment, arrangement, and operation of the vessel.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 15 November 2021
Resolved 6 November 2021
Resolution: Emergency instructions made satisfactory
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 1 November 2021 Resolved
The owner, charterer, master or managing operator shall instruct each crew member, upon first being employed and prior to getting underway for the first time on a particular vessel and at least once every three months, as to the duties that the crew member is expected to perform in an emergency including, but not limited to, the emergency instructions listed on the emergency instruction placard required by 46 CFR 185.510. Training shall be logged and include: date of the training; and general description of the training topics. Moving forward ensure this instruction is being conducted as required.
Action required: 10 - Deficiency Rectified
Resolved 1 November 2021
Resolution: Moving forward ensure this instruction is being conducted as required.
10 - Safety of Navigation › N/A - No Subsystem › Charts
Issued 1 November 2021 Resolved
As appropriate for the intended voyage, a vessel must carry adequate and up-to-date: U.S. Coast Pilot or similar publication; Coast Guard Light List; tide tables; and crrent tables. Publications were not available for inspection. Make publications (electronic) available for inspection.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 16 November 2021
Resolved 4 November 2021
Resolution: Vessel Master attested to having required publications on-board electronically.
11 - Life Saving Appliances › N/A - No Subsystem › Other (life saving)
Issued 1 November 2021 Resolved
Each survival craft on a vessel must be inspected monthly, using the manufacturer's instructions to make sure it is complete and in good order. Survival craft not being inspected as per regulations. Begin inspecting survival craft as required and document to show compliance.
Action required: 10 - Deficiency Rectified
Resolved 1 November 2021
Resolution: Begin inspecting survival craft as required and document to show compliance.
11 - Life Saving Appliances › N/A - No Subsystem › Other (life saving)
Issued 1 November 2021 Resolved
The master of the vessel shall ensure that each EPIRB must be tested monthly, using the integrated test circuit and output indicator, to determine that it is operative. The EPIRB test shall be logged. Moving forward, test EPIRB and log as required.
Action required: 10 - Deficiency Rectified
Resolved 1 November 2021
Resolution: Moving forward, test EPIRB and log as required.
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 1 November 2021 Resolved
Electrical equipment on a vessel must be installed and maintained to protect passengers, crew, other persons, and the vessel from electrical hazards, including fire, caused by or originating in electrical equipment, and electrical shock. Dead-end wires found under operating station. Remove/make wire in compliance with regulations to satisfaction of attending Marine Inspector.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 1 December 2021
Resolved 5 November 2021
Resolution: Made wireing in compliance with regulations to satisfaction of attending Marine Inspector.
07 - Fire Safety › N/A - No Subsystem › Fixed fire extinguishing installation
Issued 9 February 2021 Resolved
A FIXED FIRE EXTINGUISHING SYSTEM ABOARD A VESSEL MUST BE APPROVED BY THE COMMANDANT AND BE CUSTOM ENGINEERED TO MEET THE REQUIREMENTS FOUND IN 46 CFR 181.410. A STORAGE CYLINDER FOR A FIXED FIRE EXTINGUISHING SYSTEM MUST BE INSTALLED AT LEAST 2 INCHES BETWEEN THE DECK AND THE BOTTOM OF THE STORAGE CYLINDER. CYLINDERS MUST BE TESTED BY A CG APPROVED FACILITY AT LEAST EVERY 12 YEARS. MI DISCOVERED THAT THE CO2 STORAGE CYLINER IN THE LAZARETTE SPACE WAS ON THE DECK RESULTING IN A SIGNIFICANT AMOUNT OF CORROSION FOUND ON THE BOTTOM PORTION OF THE CYLINDER. LAST KNOWN SERVICE DATE STAMPED ON THE LAZARETTE'S CO2 CYLINDER WAS DEC 2007. VESSEL MUST PROPERLY ARRANGE CYLINDER AND HAVE REQUIRE TESTS/INSPECTIONS PERFORMED ON THIS DEVICE OR PROVIDE PLAN TO REPLACE WITH ACCEPTABLE SYSTEM. VESSEL MAY OPERATE PER COI PROVIDING LAZARETTE GENERATOR IS NOT USED (VESSEL HAS SEPARATE GENERATOR IN ENGINE ROOM) UNTIL CORRECTED.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 9 March 2021
Resolved 10 March 2021
Resolution: Vessel replaced cylinder. Examination of space did not reveal that it should be considered a regularly damp space requiring additional blocking below.
07 - Fire Safety › N/A - No Subsystem › Fire-dampers
Issued 3 September 2020 Resolved
Prove proper operation of engine room and lazerette fire dampers.
Condition: Improper/Lack of Maintenance
Action required: 60 - Rectify deficiencies prior to movement
Resolved 4 September 2020
Resolution: O/O proved proper operation of fire dampers.
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 3 September 2020 Resolved
Prove proper operation or provide a 3rd party report of a functionality test of the CO2 systems in the E/R and LAZ.
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 17 September 2020
Resolution: Vessel provided a 3rd party servicing report.
05 - Radio Communications › N/A - No Subsystem › VHF EPIRB
Issued 3 September 2020 Resolved
Replace battery on EPIRB or provide a new EPIRB with NOAA registration.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 25 September 2020
Resolution: Received photo evidence of new battery.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 3 September 2020 Resolved
Provide current alcohol swabs.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 17 September 2020
Resolution: Vessel provided unexpired alcohol swabs.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 3 September 2020 Resolved
Provide 35 adult PFD's with lights & 06 children PFD's with lights.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 17 September 2020
Resolution: Vessel provided additional lights.
09 - Working and Living Conditions › 091 - Living Conditions › Medical Equipment
Issued 20 November 2019 Resolved
First aid kit contained expired items. Provide complete and current first aid kit.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 20 December 2019
Resolved 5 December 2019
Resolution: First aid kit updated.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 20 November 2019 Resolved
Provide alcohol testing devices for all crew.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 20 December 2019
Resolved 5 December 2019
Resolution: Alcohol swabs provided.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 20 November 2019 Resolved
Provide passenger count ashore.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 20 December 2019
Resolved 5 December 2019
Resolution: PAX count ashore provided.
05 - Radio Communications › N/A - No Subsystem › Satellite EPIRB 406MHz/1.6GHz
Issued 20 November 2019 Resolved
Conduct EPIRB testing monthly.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 20 December 2019
Resolved 5 December 2019
Resolution: Monthly tests conducted.
04 - Emergency Systems › N/A - No Subsystem › Public address system
Issued 20 November 2019 Resolved
Provide public address speakers for all passenger areas.
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 20 December 2019
Resolved 5 December 2019
Resolution: PA system working.
09 - Working and Living Conditions › 091 - Living Conditions › Water, pipes, tanks
Issued 19 February 2019 Resolved
Hole was found in a fresh water system for the aft head in the flexible hose right after the pipe penetrated the bulk head and entered the engine room. Flexible hose must be replaced with approved flexible hose. 46 CFR 177.01-1
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Resolved 22 February 2019
05 - Radio Communications › N/A - No Subsystem › VHF radio installation
Issued 27 November 2018 Resolved
Provide GPS position on VHF-DSC radio.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 27 December 2018
Resolved 13 December 2018
Resolution: New VHF-DSC radio with built in GPS installed.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 27 November 2018 Resolved
Replace white 24" lifering with orange 24" lifering.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 27 December 2018
Resolved 13 December 2018
Resolution: New 24" orange lifering installed.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 27 November 2018 Resolved
Renew grab lines on liferings.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 27 December 2018
Resolved 13 December 2018
Resolution: New 24" orange lifering installed.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 27 November 2018 Resolved
Provide 60' of bouyant line and bracket for lifering light.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 27 December 2018
Resolved 13 December 2018
Resolution: 60' of polypro line and light bracket installed.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 27 November 2018 Resolved
Provide 12 additional type I adult lifejackets for a total of 65; vessel restricted to 53 persons.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 27 December 2018
Resolved 13 December 2018
Resolution: 12 new Type I adult lifejackets provided.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 27 November 2018 Resolved
Properly mark lifejacket storage locations.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 27 December 2018
Resolved 13 December 2018
Resolution: Lifejacket storage locations properly marked.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 27 November 2018 Resolved
Relocate/switch galley and bridge extinguishers to correct size.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 27 December 2018
Resolved 13 December 2018
Resolution: Fire extinguishers properly located.
Fire Fighting › Fixed CO2 Fire Extinguishing System › Servicing
Issued 19 October 2016 Resolved
Prior to ops with passengers, ensure all f/f equipment is professionally serviced and provide servicing report to USCG MI for review/approval.
Condition: Invalid
Action required: 701 - Prior to carriage of passengers/cargo
Due 19 October 2016
Resolved 21 October 2016
Operations/Management › Drug and Alcohol Testing › Testing, Pre-employment
Issued 19 October 2016 Resolved
Prior to ops with passengers, provide negative pre-employment drug test result for Master.
Condition: Placed in Improper Service
Action required: 701 - Prior to carriage of passengers/cargo
Due 19 October 2016
Resolved 20 October 2016
Communications › Radio Communications › VHF Radiotelephone
Issued 19 October 2016 Resolved
Install/prove proper operation of VHF-DSC (Class D).
Condition: Invalid
Action required: 705 - Other - as specified
Due 19 November 2016
Resolved 17 November 2016
Operations/Management › Drug and Alcohol Testing › Employee Coverage
Issued 19 October 2016 Resolved
Provide updated drug testing crew list.
Condition: Invalid
Action required: 705 - Other - as specified
Due 19 November 2016
Resolved 20 October 2016
Lifesaving › Inflatable Liferafts › Servicing
Issued 19 October 2016 Resolved
Service liferaft NLT 30NOV16
Action required: 705 - Other - as specified
Due 30 November 2016
Resolved 15 November 2016
Lifesaving › Inflatable Liferafts › Hydrostatic Release Unit
Issued 19 October 2016 Resolved
Install new hydro release for liferaft NLT 31OCT16
Action required: 705 - Other - as specified
Due 31 October 2016
Resolved 15 November 2016
Personnel › Certificates/Documents/Licenses › License, GMDSS Radio Operator
Issued 19 October 2016 Resolved
Provide FCC Marine Radio Operator Permit for Master.
Condition: Invalid
Action required: 705 - Other - as specified
Due 19 November 2016
Resolved 17 November 2016
Lifesaving › Lifebuoys › Markings (ship name/port)
Issued 19 October 2016 Resolved
Re-stencil vessel name on ring buoy
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 19 October 2016
Resolved 19 October 2016
Lifesaving › Lifejacket/PFD (Type I) › Marking
Issued 19 October 2016 Resolved
Stencli vessel name on (01) Type I PFD
Condition: Placed in Improper Service
Action required: 705 - Other - as specified
Due 19 October 2016
Resolved 19 October 2016
Lifesaving › Lifebuoys › Quantity
Issued 19 October 2016 Resolved
Provide (01) USCG-approved 24" orange ring buoy.
Condition: Placed in Improper Service
Action required: 705 - Other - as specified
Due 19 October 2016
Resolved 19 October 2016
Lifesaving › Inflatable Buoyant Apparatus › Weak Link
Issued 19 October 2016 Resolved
Re-rig IBA painter/weak link configuration.
Condition: Placed in Improper Service
Action required: 705 - Other - as specified
Due 19 October 2016
Resolved 19 October 2016
Lifesaving › Lifejacket/PFD (Type I) › Lights
Issued 19 October 2016 Resolved
Provide battery for (01) personal marker light.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 19 October 2016
Resolved 19 October 2016
Accommodation/Occupational Safety › Occupational Safety › Deck Rail
Issued 7 October 2015 Resolved
46 CFR 177.900(d)(1): Modify port & stbd deck rails to that height of top rails are at least 39.5 inches high as measured from the deck.
Condition: Placed in Improper Service
Action required: 705 - Other - as specified
Due 31 March 2017
Resolved 19 October 2016
Resolution: Cleared def iaw CG-CVC-1 Ltr dated 13OCT16 (16711/SN1322).
Accommodation/Occupational Safety › Occupational Safety › Deck Rail
Issued 7 October 2015 Resolved
Ensure compliance with restriction on passenger access to bow as required by condition of operation on COI.
Condition: Invalid
Action required: 705 - Other - as specified
Due 22 December 2015
Resolved 15 January 2016
Resolution: Based on digital photos, cleared requirement.
Documentation › Certificates/Documents › Stability Letter
Issued 8 September 2015 Resolved
Post current stability letter.
Due 8 October 2015
Resolved 23 September 2015
Resolution: Stability letter addendum was not completed/issued by MSD Santa Barbara in 2010/11 and is therefore not available to owner/operator. Stability letter addendum pending.
Communications › Radio Communications › EPIRB
Issued 8 September 2015 Resolved
Replace EPIRB hydro release by 01NOV15
Action required: 705 - Other - as specified
Due 1 November 2015
Resolved 23 September 2015
Documentation › Logs/Records › Logbook/Record (unofficial)
Issued 8 September 2015 Resolved
Log drills & lifesaving equipment checks.
Action required: 705 - Other - as specified
Due 8 October 2015
Resolved 23 September 2015
Fire Fighting › Fixed CO2 Fire Extinguishing System › Servicing
Issued 8 September 2015 Resolved
Schedule firefighting equipment servicing to coincide with deficiency check.
Action required: 705 - Other - as specified
Due 8 October 2015
Resolved 23 September 2015
Fire Fighting › Fixed Fire Detection System › UL 217 Approval
Issued 8 September 2015 Resolved
Replace 02 smoke detectors with UL-approved RV-type units.
Action required: 705 - Other - as specified
Due 8 October 2015
Resolved 23 September 2015
Fire Fighting › Fire Main › Condition
Issued 8 September 2015 Resolved
Replace corroded section of fire main piping in E/R
Action required: 705 - Other - as specified
Due 8 October 2015
Resolved 23 September 2015
Fire Fighting › Combustible Materials › Insulation
Issued 8 September 2015 Resolved
Remove lube oil-soaked insulation under stbd generator.
Action required: 705 - Other - as specified
Due 8 October 2015
Resolved 23 September 2015
Electrical › Electrical Distribution System (service) › Junction Box
Issued 8 September 2015 Resolved
Replace electrical junction box below stbd generator
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 8 October 2015
Resolved 23 September 2015
Electrical › Electrical Distribution System (service) › Outlet Box
Issued 8 September 2015 Resolved
Secure loose receptacle at forward bulkhead stbd.
Action required: 705 - Other - as specified
Due 8 October 2015
Resolved 23 September 2015
Electrical › Lighting (service) › Lighting Fixture
Issued 8 September 2015 Resolved
E/R: remove portable fluorescent light/wire from E/R.
Action required: 705 - Other - as specified
Due 8 October 2015
Resolved 23 September 2015
Electrical › Electrical Distribution System (service) › Wiring
Issued 8 September 2015 Resolved
Ensure E/R overhead electrical witing is supported at 24" intervals w/ metallic hangers.
Action required: 705 - Other - as specified
Due 8 October 2015
Resolved 23 September 2015
Electrical › Electrical Distribution System (service) › Wiring
Issued 8 September 2015 Resolved
Laz: remove dead-end wiring.
Action required: 705 - Other - as specified
Due 8 October 2015
Resolved 23 September 2015
Accommodation/Occupational Safety › Occupational Safety › Guards for Exposed Hazards
Issued 8 September 2015 Resolved
Secure belt guard on port main engine.
Action required: 705 - Other - as specified
Due 8 October 2015
Resolved 23 September 2015
Accommodation/Occupational Safety › Occupational Safety › Hand Grab
Issued 8 September 2015 Resolved
Adjust dogs on forward e-escape hatch.
Action required: 705 - Other - as specified
Due 8 October 2015
Resolved 23 September 2015
Construction/Loadline › Structures › Door
Issued 5 October 2010 Resolved
Prove proper installation of engine room forward bulkhead watertight door.
Action required: 705 - Other - as specified
Due 13 March 2011
Resolved 14 October 2010
Resolution: O/O adjusted Class I Watertight door striking plates as well as replaced all hinge pins and shim door in opening. Preformed chalk test and door passed with a marked improvement over previous test.
Electrical › Electrical Distribution System (service) › Junction Box
Issued 5 October 2010 Resolved
Make proper repairs to electrical junction box for gray water sump pump
Action required: 705 - Other - as specified
Due 5 November 2010
Resolved 14 October 2010
Resolution: O/O Made proper repairs to electrical junction box for gray water sump pump.
Operations/Management › Drug and Alcohol Testing › Proof of Enrollment
Issued 5 October 2010 Resolved
Prove enrollment in DOT testing program
Action required: 705 - Other - as specified
Due 5 November 2010
Resolved 14 October 2010
Resolution: O/O provided documentation attesting to enrollment with Maritime Drug Consortium under the name of Papagallo Yacht Charters Inc.
Engineering › Bilge Water Management System › Strainer
Issued 5 October 2010 Resolved
Install larger bilge suction strainers on all bilge lines
Action required: 705 - Other - as specified
Due 5 November 2010
Resolved 14 October 2010
Resolution: O/O installed larger bilge strainers on all bilge lines.
Engineering › Fuel Oil Service System › Hose
Issued 5 October 2010 Resolved
Make proper repairs to leaking rescue boat fuel line
Action required: 705 - Other - as specified
Due 5 November 2010
Resolved 14 October 2010
Resolution: O/O replaced leaking rescue boat fuel line.
Construction/Loadline › Hull › Side Shell
Issued 24 March 2009 Resolved
Remove wood in fpk to prevent poultice corrosion.
Action required: 705 - Other - as specified
Due 24 April 2009
Resolved 30 November 2009
Electrical › Electrical Distribution System (service) › Wiring
Issued 24 March 2009 Resolved
Wire in overhead of fpk chafing - install chafing gear.
Action required: 705 - Other - as specified
Due 24 April 2009
Resolved 12 May 2009
Construction/Loadline › Hull › Hull Plating
Issued 24 March 2009 Resolved
Crew qtrs and E/R - clean bilges thoroughly.
Action required: 705 - Other - as specified
Due 24 April 2009
Resolved 15 April 2009
Pollution Prevention/Response › Prevention Equipment › Marine Sanitation Device, Type III
Issued 24 March 2009 Resolved
Discontinue two unused sewage overboard valves.
Action required: 705 - Other - as specified
Due 24 April 2009
Resolved 15 April 2009
Construction/Loadline › Hull › Side Shell
Issued 24 March 2009 Resolved
Begin removing pegboard from E/R sideshell a laz - begin at bottom, working up about 3 ft.
Action required: 705 - Other - as specified
Due 24 May 2009
Resolved 30 November 2009
Resolution: Changed requirement to a Special Note for inspector awareness and advised O/O of risk to hull mat''l.
Communications › Radio Communications › EPIRB
Issued 6 January 2009 Resolved
Prior to ops >3NM replace EPIRB hydro release.
Action required: 701 - Prior to carriage of passengers/cargo
Due 6 January 2009
Resolved 19 February 2009
Communications › Alarms/Indicators › Bilge Alarm
Issued 6 January 2009 Resolved
Repair audible alarm for hi-water E/R bilge alarms.
Action required: 705 - Other - as specified
Due 6 February 2009
Resolved 19 February 2009
Engineering › Fuel Oil Service System › Piping
Issued 6 January 2009 Resolved
Replace flex fuel hose in E/R with appropriate hoses iaw G-MSE Policy Ltr (provided).
Action required: 705 - Other - as specified
Due 6 February 2009
Resolved 19 February 2009
Documentation › Certificates/Documents › Certificate of Inspection
Issued 6 January 2009 Resolved
Post all pages of COI in view of psgrs.
Action required: 705 - Other - as specified
Due 5 February 2009
Resolved 19 February 2009
Electrical › Electrical Distribution System (service) › Wiring
Issued 6 January 2009 Resolved
Trace/replace lamp-cord-grade wiring in laz.
Action required: 705 - Other - as specified
Due 5 February 2009
Resolved 19 February 2009
Operations/Management › Bilge/Bilge System Management › Control of Oil Mixtures
Issued 6 January 2009 Resolved
Determine source of oil leak from laz genset and make repairs.
Action required: 705 - Other - as specified
Due 5 February 2009
Resolved 19 February 2009
Communications › Alarms/Indicators › Bilge Alarm
Issued 6 January 2009 Resolved
ID and label unknown alarm panel switch.
Action required: 705 - Other - as specified
Due 6 February 2009
Resolved 6 January 2009
Navigation › Piloting/Steering › Marine Charts
Issued 6 January 2009 Resolved
Provide Chart No. 18703
Action required: 705 - Other - as specified
Due 6 February 2009
Resolved 19 February 2009
Construction/Loadline › Hull › Bottom Plating
Issued 6 January 2009 Resolved
Re-stow anchor chain to avoid contact w/aluminum hull
Action required: 705 - Other - as specified
Due 6 February 2009
Resolved 19 February 2009
Fire Fighting › Means of Escape › Blocked
Issued 6 January 2009 Resolved
Make forward e-escape hatch closure operable from both sides.
Action required: 705 - Other - as specified
Due 31 March 2009
Resolved 15 April 2009
Engineering › Sea-water System (primary cooling) › Piping
Issued 6 January 2009 Resolved
Raw water cooling supply to E/R genset: replace two hoses and hose clamps.
Action required: 705 - Other - as specified
Due 5 February 2009
Resolved 19 February 2009
Engineering › Sea-water System (primary cooling) › Piping
Issued 6 January 2009 Resolved
MDE c/w discharge piping: replace corroded piping and all painted hose sections.
Action required: 705 - Other - as specified
Due 31 March 2009
Resolved 19 February 2009
Navigation › Collision/Grounding Avoidance › Navigation Lights
Issued 6 January 2009 Resolved
Prior to ops > hbr, install mast head light and anchor light meeting UL 1104 for vessels >65'.
Action required: 705 - Other - as specified
Due 6 January 2009
Resolved 19 February 2009
Lifesaving › Inflatable Liferafts › Servicing
Issued 16 November 2007 Resolved
Service L/R and provide report. Vessel is restricted to L/B/S route until servicing report are provided.
Action required: 705 - Other - as specified
Due 17 November 2007
Resolved 19 November 2007
Lifesaving › Lifejacket/PFD (Type I) › Condition
Issued 16 November 2007 Resolved
Provide 3 adult L/Js.
Action required: 705 - Other - as specified
Due 17 November 2007
Resolved 19 November 2007
Electrical › Electrical Distribution System (service) › Circuit Breaker
Issued 16 November 2007 Resolved
Provide cover to exposed breakers in the E/R and laz.
Action required: 705 - Other - as specified
Due 15 December 2007
Resolved 27 December 2007
Electrical › Electric Supply System (service) › Battery Installation
Issued 16 November 2007 Resolved
Provide 2 new battery box in the laz.
Action required: 705 - Other - as specified
Due 15 December 2007
Resolved 27 December 2007
Documentation › Logs/Records › Drug Test Records
Issued 16 November 2007 Resolved
Provide year end summary for drug testing/program summary.
Action required: 705 - Other - as specified
Due 15 December 2007
Resolved 19 November 2007
Engineering › Freshwater Generation System › Valve, Dump
Issued 6 October 2005 Resolved
Provide valve handle IWO port side potable water discharge (O/B valve).
Action required: 705 - Other - as specified
Due 20 November 2005
Resolved 3 November 2005
Accommodation/Occupational Safety › Other Accommodation Spaces › Open Deck Space
Issued 6 October 2005 Resolved
Label emergency escape exit via FWD berthing and main cabin aft.
Action required: 705 - Other - as specified
Due 20 November 2005
Resolved 3 November 2005
Engineering › Sea-water System (primary cooling) › Valve
Issued 6 October 2005 Resolved
Provide O/B valve handle IWO O/B discharge.
Action required: 705 - Other - as specified
Due 20 November 2005
Resolved 3 November 2005
Accommodation/Occupational Safety › Occupational Safety › Rubbish/Waste Materials
Issued 6 October 2005 Resolved
Provide house keeping in area of lazarett.
Action required: 705 - Other - as specified
Due 20 November 2005
Resolved 3 November 2005
Engineering › Bilge Water Management System › Hose
Issued 6 October 2005 Resolved
Replace O/B discharge hose in the E/R.
Action required: 705 - Other - as specified
Due 20 November 2005
Resolved 3 November 2005
Personnel › Manning/Qualifications › CPR Certified Personnel
Issued 6 October 2005 Resolved
Provide CPR certification for 50% of the crew.
Action required: 705 - Other - as specified
Due 20 November 2005
Resolved 3 November 2005
Stability › Watertight Integrity › General
Issued 6 October 2005 Resolved
Repair pilot house light indicator for the E/R watertight door.
Action required: 705 - Other - as specified
Due 20 November 2005
Resolved 3 November 2005
Lifesaving › Lifejacket/PFD (General) › Lights
Issued 2 August 2005 Resolved
Provide lights for 09 lifejackets.
Due 2 August 2005
Resolved 2 August 2005
Lifesaving › Lifejacket/PFD (General) › Quantity
Issued 2 August 2005 Resolved
Provide 1 child size lifejacket.
Due 2 August 2005
Resolved 2 August 2005
Fire Fighting › Ventilation Systems › Duct Hatches
Issued 2 August 2005 Resolved
Make lazarette ventilation duct hatch vapor tight.
Due 2 August 2005
Resolved 2 August 2005
Accommodation/Occupational Safety › Medical/First Aid › Medicine Chest
Issued 2 August 2005 Resolved
Replace Aspirin in medical kit.
Due 2 August 2005
Resolved 2 August 2005
Construction/Loadline › Hull › Weld
Issued 21 July 2005 Resolved
Repair cracked weld in FWD Peak (Anchor Locker) STBD side aft, middle frame.
Action required: 705 - Other - as specified
Due 21 September 2005
Resolved 2 August 2005
Accommodation/Occupational Safety › Occupational Safety › Deck Rail
Issued 21 July 2005 Resolved
Install missing screws in handrail, port side FWD of AFT door.
Action required: 705 - Other - as specified
Resolved 21 July 2005
Communications › Radio Communications › EPIRB
Issued 24 May 2004 Resolved
Provide proof of renewal for the EPIRB hydrostatic release renewal.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 24 June 2004
Resolved 10 June 2004
Engineering › Sea-water System (primary cooling) › Piping
Issued 24 May 2004 Resolved
Replace raw water hose for the aft ship service generator inway of muffler.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 24 June 2004
Resolved 10 June 2004
Engineering › Fuel Oil Service System › Hose
Issued 24 May 2004 Resolved
Replace F/O hose between F/O pump and racor F/O filter. 46 CFR 182.720.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 24 June 2004
Resolved 10 June 2004
Electrical › Electric Supply System (service) › Cable
Issued 24 May 2004 Resolved
Submit plans for replacement of starting battery cables on the aft generator.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 24 July 2004
Resolved 10 June 2004
Accommodation/Occupational Safety › Medical/First Aid › Medicine Chest
Issued 24 May 2004 Resolved
Replace expired contents of first aid kit.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 24 May 2004
Resolved 24 May 2004
Communications › Alarms/Indicators › Bilge Alarm
Issued 24 May 2004 Resolved
Provide label for the lazarette bilge alarm indicator.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 24 May 2004
Resolved 24 May 2004
Lifesaving › Lifejacket/PFD (General)
Issued 14 August 2003 Resolved
Provide on 7 child size life jackets. LEGACY COMPONENT DESC: Condition
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 22 September 2003
Resolved 16 September 2003
Personnel › Certificates/Documents/Licenses
Issued 14 August 2003 Resolved
Provide proof of application for FCC marine radio operators permit.
Action required: 705 - Other - as specified
Due 22 September 2003
Resolved 16 September 2003
Operations/Management › Drills/Instruction
Issued 14 August 2003 Resolved
Perform satisfactory man overboard and fire drills.
Action required: 701 - Prior to carriage of passengers/cargo
Due 22 September 2003
Resolved 19 September 2003
Fire Fighting › Fire Pumps
Issued 14 August 2003 Resolved
Provide proof of fire pump operation.
Action required: 701 - Prior to carriage of passengers/cargo
Due 14 August 2003
Resolved 16 September 2003
Lifesaving › Lifebuoys
Issued 14 August 2003 Resolved
Renew batteries in ring buoy float light. LEGACY COMPONENT DESC: Self-igniting Lights
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 22 September 2003
Resolved 16 September 2003
Navigation › Piloting/Steering
Issued 14 August 2003 Resolved
Provide current coast pilot. LEGACY COMPONENT DESC: US Coast Pilot
Action required: 705 - Other - as specified
Due 22 September 2003
Resolved 16 September 2003
Communications › Alarms/Indicators › Bilge Alarm
Issued 14 August 2003 Resolved
Reconnected cable and test bilge alarm in the fwd passageway void.
Action required: 705 - Other - as specified
Due 14 August 2003
Resolved 14 August 2003
Construction/Loadline › Hull
Issued 9 April 2003 Resolved
Make forward peak available for inspection.
Due 10 May 2003
Resolved 23 May 2003
Construction/Loadline › Hull
Issued 9 April 2003 Resolved
Spot blast areas of corrosion on vessel for inspection - Make repair proposal on repairing corosion.
Due 10 April 2003
Resolved 24 April 2003
Resolution: Entire bottom blasted to white metal.
Engineering › Fuel Oil Service System
Issued 9 April 2003 Resolved
Renew all non-approved F/O hose throughout the vessel. LEGACY COMPONENT DESC: Hose
Due 10 April 2003
Resolved 16 September 2003
Electrical › Electric Supply System (service) › Cable
Issued 9 April 2003 Resolved
Submit repair proposal to renew welding cable in DC voltage system. LEGACY COMPONENT DESC: Battery Conductor
Action required: 705 - Other - as specified
Due 16 October 2003
Resolved 25 September 2003
Construction/Loadline › Hull
Issued 9 April 2003 Resolved
open up aft accomodation space for inspection.
Due 10 April 2003
Resolved 23 May 2003
Pollution Prevention/Response
Issued 9 April 2003 Resolved
Clean bilges for inspection.
Due 10 April 2003
Resolved 23 May 2003
Engineering
Issued 9 April 2003 Resolved
Remove engineroom deck plate for inspection of bilges.
Due 10 April 2003
Resolved 23 May 2003
Electrical › Electric Generation Source (service)
Issued 17 May 2002 Resolved
Install Hertz meter(s) for both ships service generators.
Due 23 June 2002
Resolved 20 June 2002
Resolution: Hertz meters were installed for BSSDG''s and shore power.
Engineering › Diesel Engine (propulsion-direct drive)
Issued 17 May 2002 Resolved
Renew/Replace both main diesel engine front oil seals. LEGACY COMPONENT DESC: Crankshaft
Due 23 June 2002
Resolved 20 June 2002
Resolution: BMDE''s oil seals were replaced with new and no longer leak.
Communications › Internal Communications System
Issued 17 May 2002 Resolved
Make aft deck speakers operational.
Due 23 June 2002
Resolved 20 June 2002
Resolution: Aft speakers are repaired and work satisfactory.
Accommodation/Occupational Safety › Medical/First Aid
Issued 17 May 2002 Resolved
Remove/replace expired items in first aid kit. LEGACY COMPONENT DESC: Medicine Chest
Due 22 May 2002
Resolved 22 May 2002
Resolution: Expired items replaced with new unexpired items.
Electrical
Issued 17 May 2002 Resolved
Clean battery posts on batteries in lazarette.
Due 22 May 2002
Resolved 22 May 2002
Resolution: Battery posts clean.
Electrical
Issued 17 May 2002 Resolved
Reconnect lose fan wire in lazarette.
Due 22 May 2002
Resolved 22 May 2002
Resolution: Fan wire has been re-connected.
Electrical › Electrical Distribution System (service)
Issued 17 May 2002 Resolved
Plug open hole in 32 volt panel in lazarette. LEGACY COMPONENT DESC: Switchboard
Due 17 May 2002
Resolved 17 May 2002
Resolution: Hole has been blanked off.
Fire Fighting › Portable Dry Chemical Fire Extinguisher
Issued 17 May 2002 Resolved
Replace/renew expired extinguisher located in pilot house. LEGACY COMPONENT DESC: Condition
Due 17 May 2002
Resolved 17 May 2002
Resolution: Pilot house fire extinguisher has been serviced.
Lifesaving › Lifejacket/PFD (Type I) › Lights
Issued 17 May 2002 Resolved
Provide lights on all life jackets prior to upgrade to coastwise route.
Due 17 May 2002
Resolved 22 May 2002
Resolution: Lights have been provided.
Lifesaving › Lifebuoys
Issued 17 May 2002 Resolved
Upgrade ring lifebuoys to orange prior to upgrade to coastwise route.
Due 17 May 2002
Resolved 22 May 2002
Resolution: Orange ring buoys have been provided.
Engineering › Fuel Oil Storage/Transfer System
Issued 17 May 2002 Resolved
Replace/renew fuel vent screens on fuel vent pipes. LEGACY COMPONENT DESC: Vent Pipe
Due 17 May 2002
Resolved 22 May 2002
Resolution: New screens have been installed on all fuel vent pipes.
Electrical
Issued 26 May 2000 Resolved
REPLACE IMPROPER WIRE ON 12VDC OUTLET IN CONTROL PANEL IN PILOT HOUSE.
Condition: Unknown
Due 26 May 2000
Resolved 26 May 2000
Fire Fighting
Issued 26 May 2000 Resolved
PROVIDE PROPER FIRE EXTINGUISHER BRACKETS THROUGHOUT VESSEL.
Condition: Unknown
Due 26 May 2000
Resolved 26 May 2000
Lifesaving
Issued 11 January 2000 Resolved
Port light covers below main deck were installed.
Condition: Unknown
Due 11 January 2000
Resolved 18 January 2000
Unknown
Issued 11 January 2000 Resolved
Dead light covers installed
Condition: Unknown
Due 11 January 2000
Resolved 12 January 2000
Electrical
Issued 25 May 1999 Resolved
PROVE PROPER OPERATION OF EMERGENCY LIGHTING IN CREW QUARTERS PASSAGEWAY.
Condition: Unknown
Due 25 May 1999
Resolved 25 May 1999
Construction/Loadline
Issued 25 May 1999 Resolved
INSTALL CHECK VALVES IN INDIVIDUAL SUCTION LINES.
Condition: Unknown
Due 25 May 1999
Resolved 25 May 1999
Construction/Loadline
Issued 25 May 1999 Resolved
INSTALL BILGE HIGH LEVEL ALARM IN LAZERETTE.
Condition: Unknown
Due 25 May 1999
Resolved 25 May 1999
Unknown
Issued 25 May 1999 Resolved
INSTALL DEAD LIGHT COVERS ON ALL PORT LIGHTS BELOW THE MAIN DECK.
Condition: Unknown
Due 25 May 1999
Resolved 25 May 1999
Engineering
Issued 10 June 1998 Resolved
INSTALL 30X30 MESH IN FUEL VENTS.
Condition: Unknown
Due 10 June 1998
Resolved 10 June 1998
Accommodation/Occupational Safety
Issued 10 June 1998 Resolved
STENCIL EMERGENCY ESCAPE INSIDE AND OUTSIDE.
Condition: Unknown
Due 10 June 1998
Resolved 10 June 1998
Lifesaving
Issued 10 June 1998 Resolved
PROVIDE AND MOUNT LIFEJACKET DONNING PLACARD
Condition: Unknown
Due 10 June 1998
Resolved 10 June 1998
Unknown
Issued 10 June 1998 Resolved
UPDATE EQUIPMENT IN FIRST AID KIT.
Condition: Unknown
Due 10 June 1998
Resolved 10 June 1998
Navigation
Issued 10 June 1998 Resolved
PROVIDE COPY OF RADIO OPERATOR PERMIT.
Condition: Unknown
Due 10 June 1998
Resolved 10 June 1998
Navigation
Issued 10 June 1998 Resolved
PROVIDE COPY OF EMERGENCY BROADCAST INFORMATION.
Condition: Unknown
Due 10 June 1998
Resolved 10 June 1998
Fire Fighting
Issued 10 June 1998 Resolved
REPLACE INOPERATIVE HAND PUMP.
Condition: Unknown
Due 10 June 1998
Resolved 10 June 1998
Lifesaving
Issued 5 June 1997 Resolved
PROVIDE AND PROPERLY MOUNT CLASS 1, 406 EPIRB AS REQUIRED BY 46 CFR 180.64.THE VESSEL IS LIMITED TO LAKES, BAYS, AND SOUNDS ROUTE UNTIL THIS REQUIREMENT IS MET THE SATISFACTION OF THE ATTENDING MARINE INSPECTOR.
Condition: Unknown
Due 10 June 1997
Resolved 10 June 1997
Documentation
Issued 6 June 1996 Resolved
PROVIDE CURRENT FCC RADIO STATION LICENSE
Condition: Unknown
Due 6 June 1996
Resolved 6 June 1996
Fire Fighting
Issued 24 April 1995 Resolved
PROVIDE (1) 1.5" X 50' UL FIRE HOSE. PRIOR TO SAILING.
Condition: Unknown
Due 1 June 1995
Resolved 31 May 1995
Engineering
Issued 24 April 1995 Resolved
INSTALL FLAME SCREENS FOR FUEL VENTS ON PORT SIDE, PRIOR TO SAILING.
Condition: Unknown
Due 1 June 1995
Resolved 31 May 1995
Documentation
Issued 24 April 1995 Resolved
PROVIED VALID OPERATOR LICENSE.
Condition: Unknown
Due 1 June 1995
Resolved 31 May 1995
Electrical
Issued 24 April 1995 Resolved
BLOCK BATTERIES IN ENGINE ROOM.
Condition: Unknown
Due 1 June 1995
Resolved 31 May 1995
Documentation
Issued 24 April 1995 Resolved
PROVIDE VALID FCC RADIO OPERATOR PERMIT.
Condition: Unknown
Due 1 June 1995
Resolved 31 May 1995
Navigation
Issued 24 April 1995 Resolved
MOUNT PORT/STBD NAVIGATION LIGHTS OR PAINT SCREENS SO SCREENS ARE FLAT BLACK.
Condition: Unknown
Due 31 May 1995
Resolved 31 May 1995
Fire Fighting
Issued 24 April 1995 Resolved
LABEL FIRE STATIONS.
Condition: Unknown
Due 1 June 1995
Resolved 31 May 1995
Documentation
Issued 24 April 1995 Resolved
PROVIDE VALID FCC RADIO TELEPHONY CERTIFICATE.
Condition: Unknown
Due 24 April 1995
Resolved 24 April 1995
Accommodation/Occupational Safety
Issued 20 April 1994 Resolved
PROVIDE MARPOL V PLACARD (GARBAGE/PLASTICS).
Condition: Unknown
Due 20 April 1994
Resolved 20 April 1994
Lifesaving
Issued 20 April 1994 Resolved
PROVIDE 3 ADULT LIFE PRESERVERS. VESSEL IS RESTRICTED TO CARRYING A TOTAL OF 62 PERSONS UNTIL CLEARED.
Condition: Unknown
Due 20 April 1994
Resolved 20 April 1994
Engineering
Issued 20 April 1994 Resolved
REPLACE ALL FUEL TANK VENT SCREENS WITH 30 X 30 MESH.
Condition: Unknown
Due 20 April 1994
Resolved 20 April 1994
Accommodation/Occupational Safety
Issued 20 April 1994 Resolved
REINSTALL VENT FOR POTABLE WATER AND INSTALL BUG SCREEN.
Condition: Unknown
Due 20 April 1994
Resolved 20 April 1994
Documentation
Issued 20 April 1994 Resolved
PROVIDE OIL POLLUTION PLACARD.
Condition: Unknown
Due 20 April 1994
Resolved 20 April 1994
Fire Fighting
Issued 10 May 1993 Resolved
PROVIDE BRACKETS FOR PORTABLE FIRE EXTINGUISHERS.
Condition: Unknown
Due 24 May 1993
Resolved 20 May 1993
Lifesaving
Issued 10 May 1993 Resolved
PROVIDE 6 ORANGE FLARES.
Condition: Unknown
Due 24 May 1993
Resolved 20 May 1993
Fire Fighting
Issued 10 May 1993 Resolved
PROVIDE 2 CG APPROVED FIRE NOZZELS.
Condition: Unknown
Due 24 May 1993
Resolved 20 May 1993
Lifesaving
Issued 10 May 1993 Resolved
REPLACE RETRO-TAPE ON BUOYANT APPARATUS'.
Condition: Unknown
Due 24 May 1993
Resolved 20 May 1993
Lifesaving
Issued 10 May 1993 Resolved
LABEL CHILD PFD STOWAGE LOCKER.
Condition: Unknown
Due 24 May 1993
Resolved 20 May 1993
Lifesaving
Issued 10 May 1993 Resolved
PROVIDE 7 ADULT PFD'S. VSL IS RESTRICTED TO CARRYING 55 PASSENGERS UNTIL 7 PFD'S PROVIDED.
Condition: Unknown
Due 24 May 1993
Resolved 20 May 1993
Lifesaving
Issued 12 June 1992 Resolved
REPAIR/REPLACE BUOYANT APPARATUS.
Condition: Unknown
Due 6 July 1992
Resolved 6 July 1992
Accommodation/Occupational Safety
Issued 12 June 1992 Resolved
MARK HATCH ON VESSEL BOW "ESCAPE HATCH, KEEP CLEAR."
Condition: Unknown
Due 6 July 1992
Resolved 6 July 1992
Accommodation/Occupational Safety
Issued 25 June 1991 Resolved
PROVIDE MARPOL V PLACARD._x001C_ _x001C_
Condition: Unknown
Due 25 August 1991
Resolved 29 August 1991
Documentation
Issued 25 June 1991 Resolved
PROVIDE WASTE MANAGEMENT PLAN.
Condition: Unknown
Due 25 August 1991
Resolved 29 August 1991
Fire Fighting
Issued 25 June 1991 Resolved
PROVIDE SUCTION HOSE FOR PORTABLE FIRE AND BILGE PUMP.
Condition: Unknown
Due 25 June 1991
Resolved 29 August 1991
Fire Fighting
Issued 25 June 1991 Resolved
REPLACE FIRE HOSE NOZZLES WITH APPROVED TYPE._x001C_ _x001C_ _x001C_
Condition: Unknown
Due 25 August 1991
Resolved 29 August 1991
Documentation
Issued 25 June 1991 Resolved
PROVIDE DOCUMENTATION OF DRUG TESTING PROGRAM.
Condition: Unknown
Due 25 June 1991
Resolved 25 June 1991
Fire Fighting
Issued 25 June 1991 Resolved
PROVIDE REMOTE MEANS OF SHUTTING DOWN ENG RM AND LAZARETTE VENTILATION IN THE EVENT OF FIRE OR CO2 RELEASE.
Condition: Unknown
Due 25 August 1991
Resolved 29 August 1991
Fire Fighting
Issued 25 June 1991 Resolved
FIT LAZARETTE WITH FIRE DETECTION SYSTEM.
Condition: Unknown
Due 25 August 1991
Resolved 29 August 1991
Accommodation/Occupational Safety
Issued 5 April 1990 Resolved
INSTAL EMERGENCY LIGHTING IN FWD PASSENGER AREA. LIGHTING IS TO COME ON AUTOMATICALLY WITH LOSS OF AC POWER AND STAY ON FOR 6 HOURS.
Condition: Unknown
Due 5 April 1990
Resolved 5 April 1990
Accommodation/Occupational Safety
Issued 5 April 1990 Resolved
SUBMIT PLANS FOR EMERGENCY LIGHTING INSTALLATION BELOW MAIN DECK (FORWARD AREA) PRIOR TO INSTALLATION FOR MSO APPROVAL.
Condition: Unknown
Due 5 April 1990
Resolved 5 April 1990
Construction/Loadline
Issued 5 April 1990 Resolved
OPEN ALL SQUARE NON-METALIC VALVES FOR INSPECTION. PROVE MSD AND OTHER VALVES ARE NOT CONSTRUCTED OF PVC. THIS IS TO BE COMPLETED PRIOR TO COMING OFF DRYDOCK
Condition: Unknown
Due 5 April 1990
Resolved 5 April 1990
Construction/Loadline
Issued 5 April 1990 Resolved
PROVIDE COPY OF GUAGING REPORT FOR REVIEW (AND ALSO NEED TO OBTAIN ORIGINALSCANTLINGS) PRIOR TO GOING OFF DRYDOCK.
Condition: Unknown
Due 5 April 1990
Resolved 5 April 1990
Lifesaving
Issued 5 April 1990 Resolved
PROVIDE AN ADDITIONAL 6 CHILD PFDS AND 2 ADULT PFDS. UNTIL THESE ARE PROVIDED NO CHILDREN MAY BE CARRIED AND PASSENGERS ARE LIMITED TO 61.
Condition: Unknown
Due 5 April 1990
Resolved 5 April 1990
Engineering
Issued 23 June 1989 Resolved
HYDRO TEST WAY-WOOLF WATER HEATING BOILER AT ONE AND A QUARTER TIMES THE MAWP.
Condition: Unknown
Due 23 June 1989
Resolved 23 June 1989
Engineering
Issued 23 June 1989 Resolved
INSTALL EMERGENCY FUEL SHUT-OFF VALVE AND REMOTE HANDLE ON AFTMOST FUEL TANK SUPPLY LINE.
Condition: Unknown
Due 23 June 1989
Resolved 23 June 1989
Fire Fighting
Issued 24 April 1989 Resolved
PROVIDE COPY OF SERVICE REPORT FOR FIXED AND PORTABLE FIRE EXTINGUISHERS TO OCMI.
Condition: Unknown
Due 24 April 1989
Resolved 24 April 1989
Construction/Loadline
Issued 24 April 1989 Resolved
MAKE WATERTIGHT HEAD DISCHARGE PIPE CONDUIT THROUGH BULKHEAD BETWEEN ENGINEROOM AND CREWS QUARTERS.
Condition: Unknown
Due 24 April 1989
Resolved 24 April 1989
Lifesaving
Issued 21 April 1987 Resolved
PROVIDE 3 ADULT LIFEPRESERVERS AND 1 CHILDS LIFE PRESERVER. VESSEL IS RESTRICTED TO 60 TOTAL PERSONS ALLOWED AND 6 CHILDREN UNTIL CORRECTED
Condition: Unknown
Due 21 April 1987
Resolved 21 April 1987
Documentation
Issued 21 April 1987 Resolved
PROVIDE CURRENT FCC SAFETY RADIOTELEPHONY CERTIFICATE.
Condition: Unknown
Due 21 April 1987
Resolved 21 April 1987
Electrical
Issued 16 April 1985 Resolved
PROVIDE COVER FOR JUNCTION BOX PORT SIDE OVERHEAD IN ENGINE ROOM.
Condition: Unknown
Due 16 April 1985
Resolved 16 April 1985
Electrical
Issued 16 April 1985 Resolved
PROVIDE RUBBER MATTING FOR ENGINE ROOM ELECTRICAL BOARD.
Condition: Unknown
Due 16 April 1985
Resolved 16 April 1985
Documentation
Issued 16 April 1985 Resolved
PROVIDE AND POST EMERGENCY CHECK-OFF LIST.
Condition: Unknown
Due 16 April 1985
Resolved 16 April 1985
Lifesaving
Issued 16 April 1985 Resolved
LABEL LIFE JACKET LOCKERS.
Condition: Unknown
Due 16 April 1985
Resolved 16 April 1985
Electrical
Issued 16 April 1985 Resolved
PROVIDE BATERY CONTAINER IN LAZERETTE.
Condition: Unknown
Due 16 April 1985
Resolved 16 April 1985
Fire Fighting
Issued 16 April 1985 Resolved
PROVIDE OR RESERVICE TWO FIRE EXTINGUISHERS (1) IN FORWARD HEAD AND (2) IN ENGINE ROOM.
Condition: Unknown
Due 16 April 1985
Resolved 16 April 1985
Navigation
Issued 16 April 1985 Resolved
PROVIDE NEW "RULES OF THE ROAD" BOOK.
Condition: Unknown
Due 16 April 1985
Resolved 16 April 1985

Casualty record · 2

5 December 2005Routine · role: Involved in a Marine Casualty · activity 2548237
5 September 2015Routine · role: Involved in a Marine Casualty · serious marine incident, as classified · 1 dead · activity 5733838
Each line is an incident investigation the Coast Guard recorded with this hull among the vessels involved, with the date and the classification the Coast Guard gave it, and the bridge, lock or dam the investigation names where it names one. Involvement is not fault. The investigation narrative is not published. Source: IIR, through 2026.

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.