← All vessels
PAPAGALLO II
Passenger (Inspected) · Passenger Ship class · Built 1960s · USCG Southwest District (CGD-SW) · Other hulls named PAPAGALLO II
PAPAGALLO II is a 1964 passenger vessel (inspected). The Coast Guard has recorded 81 inspections since 1984, most recently in April 2025, along with 211 deficiencies, 3 operational controls and 2 casualty investigations between 2005 and 2015.
Records from 1984 to 2025. Most recent: inspection, 24 April 2025.
- Built
- 1964
- Last inspected
- 24 April 2025
- Documentation
- Valid · documentation file of 10 September 2026
- Deficiencies
- 211 recorded · 0 without a recorded resolution
- Controls
- None recorded without a removal date
- Casualties
- 2 investigations · 2005–2015
Identity
294842
WDC9874
54895
Flag
UNITED STATES
367107830 (licence lapsed)
Maury page id
psix-54895
Inspections, by type
…with no type recorded11
Years with a record
37 calendar years (1984–2025)
The 81 inspections in the strip above, split by the kind of activity the US
Coast Guard recorded. Years with a record are calendar years in which a record exists, not
years in service. What Maury does not do.
Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 1977.
Documentation record
Registered dimensions (L × B × D)71.0 ft × 17.2 ft × 8.0 ft
Registered tonnagegross 65 / net 52
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderBURGER BOAT CO INC · MANITOWOC, WI, UNITED STATES · built 1964
Hull materialAluminum
PropulsionDiesel Reduction
Hull shapeShip
Hull configurationMonohull
Hailing portSAN FRANCISCO, CA
Trade endorsementsCoastwise, unrestricted
DocumentationValid · issued 26 November 2025 · expires 31 October 2026
Service, as the file records itPassenger (Inspected)
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it65 - Simplified, Gross Ton
52 - Simplified, Net Ton
52 - Simplified, Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 September 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
Radio station licence
WDC9874MMSI 367107830 · expired · compulsorily equipped · granted 8 March 2016, cancelled 20 June 2026
WCW7239MMSI not assigned · expired · voluntarily equipped · granted 8 July 1996, cancelled 9 September 2006
FCC Universal Licensing System ship-station file of 6 September 2026, matched to this hull on its
US Official Number. Status and dates are the file’s own. The licensee is not read from the file and is not shown.
A lapsed licence’s MMSI is still the number the vessel transmitted under while it was valid.
Inspection history · 81
24 April 2025
Drydock Exam · Internal Structural Exam · Hull Examination · Administrative Inspection
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 8118164
12 November 2024
Annual Inspection
Physical examination · Marine Safety Detachment Santa Barbara · USCG Southwest District (CGD-SW) · Activity 8096977
27 November 2023
Deficiency Check
Physical examination · Marine Safety Detachment Santa Barbara · USCG Southwest District (CGD-SW) · Activity 7830034
24 October 2023
Annual Inspection · Administrative Inspection
Physical examination · Marine Safety Detachment Santa Barbara · USCG Southwest District (CGD-SW) · Activity 7812847
30 March 2023
Drydock Exam · Hull Examination · Deficiency Check · Internal Structural Exam
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 7658683
1 March 2023
Deficiency Check · Administrative Inspection
Physical examination · Marine Safety Detachment Santa Barbara · USCG Southwest District (CGD-SW) · Activity 7645445
17 November 2022
Deficiency Check · Administrative Inspection · Annual Inspection
Physical examination · Marine Safety Detachment Santa Barbara · USCG Southwest District (CGD-SW) · Activity 7576390
1 November 2021
Annual Inspection · Deficiency Check
Physical examination · Marine Safety Detachment Santa Barbara · USCG Southwest District (CGD-SW) · Activity 7326770
10 March 2021
Deficiency Check
Physical examination · Marine Safety Detachment Santa Barbara · USCG Southwest District (CGD-SW) · Activity 7150016
9 February 2021
Internal Structural Exam · Drydock Exam · Hull Examination
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 7135828
3 September 2020
COI Inspection
Physical examination · Marine Safety Detachment Santa Barbara · USCG Southwest District (CGD-SW) · Activity 7037519
20 November 2019
Annual Inspection · Deficiency Check
Physical examination · Marine Safety Detachment Santa Barbara · USCG Southwest District (CGD-SW) · Activity 6849186
7 August 2019
Plan Review "T" Boat
Administrative · Marine Safety Detachment Santa Barbara · USCG Southwest District (CGD-SW) · Activity 6782241
19 February 2019
Internal Structural Exam · Administrative Inspection · Drydock Exam
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 6628469
27 November 2018
Annual Inspection
Physical examination · Marine Safety Detachment Santa Barbara · USCG Southwest District (CGD-SW) · Activity 6578197
16 November 2017
Annual Inspection
Physical examination · Marine Safety Detachment Santa Barbara · USCG Southwest District (CGD-SW) · Activity 6300348
22 March 2017
Drydock Exam · Administrative Inspection · Internal Structural Exam
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 6109253
19 October 2016
Annual Inspection
Physical examination · Marine Safety Detachment Santa Barbara · USCG Southwest District (CGD-SW) · Activity 6015103
7 October 2015
Administrative Inspection · In-Service Inspection
Physical examination · Marine Safety Detachment Santa Barbara · USCG Southwest District (CGD-SW) · Activity 5738606
8 September 2015
Deficiency Check · COI Inspection
Physical examination · Marine Safety Detachment Santa Barbara · USCG Southwest District (CGD-SW) · Activity 5234399
5 September 2015
Type not recorded
No type recorded · Marine Safety Detachment Santa Barbara · USCG Southwest District (CGD-SW) · Activity 5733838
5 October 2010
DAPI Audit · COI Inspection · Deficiency Check
Physical examination · Marine Safety Detachment Santa Barbara · USCG Southwest District (CGD-SW) · Activity 3854812
24 March 2009
Deficiency Check · Hull Examination
Physical examination · Marine Safety Detachment Santa Barbara · USCG Southwest District (CGD-SW) · Activity 3439456
6 January 2009
Annual Inspection
Physical examination · Marine Safety Detachment Santa Barbara · USCG Southwest District (CGD-SW) · Activity 3389137
20 March 2008
Type not recorded
No type recorded · Station Morro Bay · USCG Southwest District (CGD-SW) · Activity 3168597
16 November 2007
Periodic Inspection
Physical examination · Marine Safety Detachment Santa Barbara · USCG Southwest District (CGD-SW) · Activity 3099627
28 March 2007
Hull Examination
Physical examination · Marine Safety Detachment Santa Barbara · USCG Southwest District (CGD-SW) · Activity 2896696
5 December 2005
Type not recorded
No type recorded · Marine Safety Detachment Santa Barbara · USCG Southwest District (CGD-SW) · Activity 2548237
6 October 2005
Administrative Inspection · COI Inspection · Deficiency Check
Physical examination · Marine Safety Detachment Santa Barbara · USCG Southwest District (CGD-SW) · Activity 2508980
10 August 2005
Administrative Inspection
Administrative · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 2465691
2 August 2005
Annual Inspection
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 2345844
21 July 2005
Hull Examination
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 2345841
12 May 2005
Liferaft Servicing
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 2356084
19 May 2004
Plan Review "T" Boat · Annual Inspection · Deficiency Check
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 2072446
14 August 2003
Deficiency Check · Plan Review "T" Boat · Annual Inspection
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1875866
9 April 2003
Hull Examination
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1757474
17 May 2002
Deficiency Check · COI Inspection
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1606261
3 July 2001
Re-Inspection
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1379502
17 April 2001
Type not recorded
No type recorded · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1062495
12 April 2001
Hull Examination
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1382174
26 May 2000
Re-Inspection
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1408525
11 January 2000
Deficiency Check
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 814281
11 January 2000
Deficiency Check
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 815139
7 December 1999
Type not recorded
No type recorded · USCGC OSPREY (WPB 87307) · USCG Northwest District (CGD-NW) · Activity 1512163
7 June 1999
Deficiency Check
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1093323
25 May 1999
COI Inspection
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1464847
15 March 1999
Hull Examination
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1395136
29 September 1998
Deficiency Check
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 802018
10 June 1998
Re-Inspection
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 798264
5 June 1997
Re-Inspection
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1447720
16 April 1997
Hull Examination
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1102545
6 June 1996
COI Inspection
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1456364
24 April 1995
Deficiency Check · Hull Examination · COI Inspection
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1400174
22 June 1994
Deficiency Check
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1023666
20 April 1994
COI Inspection
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1170448
10 May 1993
COI Inspection
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 830929
9 April 1993
Hull Examination
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 832503
12 June 1992
Deficiency Check · COI Inspection
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 956610
13 November 1991
Deficiency Check
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 945545
11 July 1991
Administrative
Administrative · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1247637
25 June 1991
COI Inspection
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 938096
18 June 1991
Hull Examination
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1197187
23 May 1990
Deficiency Check
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1219089
5 April 1990
COI Inspection · Hull Examination
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 907750
21 September 1989
Deficiency Check
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1202613
11 August 1989
Deficiency Check
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 894150
23 June 1989
Type not recorded
No type recorded · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1197008
24 April 1989
Deficiency Check · COI Inspection
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1032186
23 August 1988
Type not recorded
No type recorded · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1344672
11 May 1988
Deficiency Check
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1044223
6 May 1988
Hull Examination · COI Inspection
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1034192
26 June 1987
Administrative
Administrative · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1315482
21 April 1987
COI Inspection
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1314125
23 September 1986
Credit Drydock
Administrative · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1312324
24 April 1986
COI Inspection
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 997058
16 September 1985
Deficiency Check
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1302410
10 September 1985
Credit Drydock · Deficiency Check
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 989200
3 May 1985
Type not recorded
No type recorded · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1286196
16 April 1985
Type not recorded
No type recorded · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1292000
31 January 1985
Type not recorded
No type recorded · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 977615
16 November 1984
Type not recorded
No type recorded · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 976787
Deficiency record · 211
03 - Water/Weathertight Conditions › N/A - No Subsystem › Windows, sidescuttles and deadlights
Issued 24 April 2025
Resolved
If a vessel operates on exposed or partially protected waters, an opening port light is not permitted below the weather deck unless—(1) The sill is at least 30 inches (76.2 centimeters) above the deepest subdivision load line; and(2) It has an inside, hinged dead cover.
1.Portside forward engine room hinged dead cover for port light had a torn gasket; and 2.Starboardside aft engine room hinged dead cover for port light had a missing wing-nut for closing/watertightness. Replace both the gasket and wing-nut to the satisfaction of Marine Inspector. Due prior to credit drydock. 46 CFR 171.119(a)(2)
07 - Fire Safety › N/A - No Subsystem › Fire-dampers
Issued 24 October 2023
Resolved
Provision must be made for closing all supply duct cowls or scoops and exhaust duct discharge openings for a space protected by a fixed gas extinguishing system. All closure devices must be readily available and mounted in the vicinity of the vent. Port damper located in lazarette which is covered by fixed CO2 extinguishing did not close upon test actuation. Damper must be corrected prior to operation of lazarette auxiliary engine. 46 CFR 182.465(h)
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 24 October 2023
Resolved
Each entrance to a space storing carbon dioxide cylinders, a space protected by carbon dioxide systems, or any space into which carbon dioxide might migrate must be conspicuously marked as follows: Spaces protected by carbon dioxide—“CARBON DIOXIDE GAS CAN CAUSE INJURY OR DEATH. WHEN ALARM OPERATES OR WINTERGREEN SCENT IS DETECTED, DO NOT ENTER UNTIL VENTILATED. LOCK OUT SYSTEM WHEN SERVICING.” The reference to wintergreen scent may be omitted for carbon dioxide systems not required to have odorizing units and not equipped with such units. Markings and warnings were not provided for lazarette and machinery spaces protected by fixed CO2 extinguishing.
46 CFR 185.612(g)
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 1 March 2023
Resolved
A vessel that is exposed to salt water more than three
months in any 12 month period since the last examination
must undergo a dry-dock examination and an internal
structural examination at least once every two years. As
per her COI, vessel is currently outside compliance and
can no longer operate under the conditions of her COI.
The vessel may operate in the following alternative
services, within the limits of the vessel’s current
stability letter:
(a) as a small passenger vessel, carrying 6 or less
passengers without deck cargo, with one licensed master.
(b) as a bareboat chartered recreational vessel carrying
12 or less passengers with no crew provided by the
Owner/Operator.
Vessel must undergo a satisfactory dry-docking in
compliance with 46 CFR Sub-chapter T, in the presence of
a USCG Marine Inspector, in order to clear this
deficiency.
07 - Fire Safety › N/A - No Subsystem › Fixed fire extinguishing installation
Issued 17 November 2022
Resolved
At each initial and subsequent inspection for
certification, the owner or managing operator must be
prepared to conduct tests and have the vessel ready for
inspection of its fire protection equipment, including
inspection of controls for each fixed gas fire
extinguishing system and detection system to determine
that the system is in operating condition. Pressure
switches in E/R and lazerette were found to not have
been serviced as per records provided from owner.
Provide proof of satisfactory servicing of pressure
switches, and inform this office what the pressure
switches function are, to attending Marine Inspector.
05 - Radio Communications › N/A - No Subsystem › Satellite EPIRB 406MHz/1.6GHz
Issued 17 November 2022
Resolved
Each disposable hydrostatic release unit (HRU) must be
marked with an expiration date of two years after the
date on which the unit is installed (or as per
manufacturer recommendations). HRO was marked as
expired. Replace w/ properly marked HRU to manufacturer
specifications. Vessel must stay within 03 miles of a
harbor of safe refuge until resolved and made
satisfactory to attending Marine Inspector.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 17 November 2022
Resolved
Each life jacket carried on a vessel on a coastwise
route, must have a life jacket light approved in
accordance with § 161.012 in subchapter Q of this chapter, or other standard specified by the
Commandant, including, but not limited to, approval
series 160.112. Numerous lifejacket lights were not
operable. Until this deficiency is corrected, the vessel
is limited to a route that does not extend more than 20
miles from a harbor of safe refuge. Vessel must make
life jackets in compliance to the satisfaction of
attending Marine Inspector.
11 - Life Saving Appliances › N/A - No Subsystem › Distress flares
Issued 17 November 2022
Resolved
A vessel on coastwise route must carry six hand
red flare distress signals & six hand orange smoke
distress signals. Six hand red flare distress signals
can be substituted for six hand orange smoke distress
signals. Vessel was missing 08 distress signals. Vessel
is limited to short runs approximately 30 minutes away
from the dock. Make number and type of distress signals
as required for route on COI.
18 - Maritime Labour Convention (Not Applicable to PSC Exams conducted in the U.S.) › N/A - No Subsystem › Other (Conditions of employment)
Issued 17 November 2022
Resolved
The marine employer must have a sufficient number of
alcohol testing devices readily accessible on board the
vessel to determine the presence of alcohol in the
system of each individual who was directly involved in
the SMI. Vessel's testing devices were unavailable.
Until such time that valid testing devices are available
onboard,vessel must stay within 2 hours of a location to
perform the required alcohol tests from the time of
occurrence of the SMI. Vessel will need to replace
testing devices as required and or show written policy attesting to how the vessel will obtain the
devices and conduct the required alcohol tests within 2
hours from the time of occurrence of the SMI.
01 - Certificates & Documentation › 011 - Ships Certificates › Cargo Ship Safety Radio (including exemption)
Issued 17 November 2022
Resolved
Each ship transporting more than six passengers for hire
equipped with a radiotelephone station in accordance
with Part III of Title III of the Communications Act
must carry a radio operator who meets the following
requirements: (1) Where the station power does not
exceed 250 watts carrier power or 1500 watts peak
envelope power, the radio operator must hold a marine
radio operator permit or higher class license. (2) Where
the station power exceeds 250 watts carrier power or
1500 watts peak envelope power, the radio operator must
hold a general radiotelephone operator license or higher
class license. Vessel Master/owner did not have
available a Federal Communications Commission Marine
Radio Operator Permit. Provide valid Federal
Communications Commission Marine Radio Operator Permit.
01 - Certificates & Documentation › 011 - Ships Certificates › Other (certificates)
Issued 17 November 2022
Resolved
The person in command of a documented vessel must have
on board that vessel the original Certificate of
Documentation (COD) currently in effect for that vessel.
Vessel did not have valid COD on board. Provide proof of
valid COD to attending Marine Inspector.
09 - Working and Living Conditions › 091 - Living Conditions › Medical Equipment
Issued 17 November 2022
Resolved
The owner, charterer, master or managing operator shall
instruct each crew member, at least once every three
months, as to the duties that the crew member is expected to perform in an emergency including, but not
limited to, the emergency instructions listed on the
emergency instruction placard required by 46 CFR
185.510. Vessel was not able to produce logged drills
for abandon ship and man overboard. Provide next logged
drills within 30 days to attending Marine Inspector &
continue as internal policy as required by the
regulations.
09 - Working and Living Conditions › 091 - Living Conditions › Medical Equipment
Issued 17 November 2022
Resolved
A vessel must carry either a first-aid kit approved
under approval series 46 CFR 160.041 or a kit with
equivalent contents and instructions. Items in kit were
expired/missing. Make kit in compliance with
regulations.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 17 November 2022
Resolved
Each ring life buoy must be marked in clearly legible
block capital letters with the vessel's name. 02
required ring life buoys were not marked with the
vessel's name. Have ring life buoy's marked in
accordance with regulations and to the satisfaction of
the attending Marine Inspector.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 17 November 2022
Resolved
The number and identification of life jackets stowed
inside, and their sizes, must be marked in clearly
legible letters and numbers on each container for life
jackets. Letters and numbers must be at least 2 inches
high. Containers for life jackets were not correctly
marked. Make containers and stowage as required by
regulation.
07 - Fire Safety › N/A - No Subsystem › Fixed fire extinguishing installation
Issued 1 November 2021
Resolved
At each initial and subsequent inspection for
certification, the owner or managing operator must be
prepared to conduct tests and have the vessel ready for
inspection of its fire protection equipment, including
inspection of controls for each fixed gas fire
extinguishing system and detection system to determine
that the system is in operating condition. Heat
activated device was found to not have been serviced as
per records provided from owner. Provide proof of
satisfactory servicing of heat activated device in
lazerette to attending Marine Inspector.
11 - Life Saving Appliances › N/A - No Subsystem › Inflatable liferafts
Issued 1 November 2021
Resolved
Each disposable hydrostatic release unit (HRU) must be
marked with an expiration date of two years after the
date on which the unit is installed. Markings on vessels
IBA HRU were non-existent or unreadable. HRU was
installed upside down. Replace with properly marked/
installed HRU to manufacturer specifications. Make
satisfactory to attending Marine Inspector.
11 - Life Saving Appliances › N/A - No Subsystem › Inflatable liferafts
Issued 1 November 2021
Resolved
Each survival craft must be stowed so that when the
vessel sinks the survival craft floats free. Float free
configuration was not installed correctly on vessel IBA.
Correct float free configuration to manufacturer
specifications and Marine Inspector satisfaction.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 1 November 2021
Resolved
At least one ring life buoy must be fitted with a
lifeline. Each lifeline on a ring life buoy must be
buoyant; be of at least 60 feet in length; be nonkinking;
have a diameter of at least 5 16 inch; have a
breaking strength of at least 1,124 pounds; and be of a
dark color if synthetic, or of a type certified to be
resistant to deterioration from ultraviolet light.
Lifeline was not fitted to ring life buoy. Fit
appropriate lifeline to ring life buoy.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 1 November 2021
Resolved
A vessel must carry one floating waterlight, unless it
is limited to daytime operation. Each ring life buoy
with a floating waterlight must have a lanyard of at
least 3 feet in length, but not more than 6 feet,
securing the waterlight around the body of the ring life
buoy. Vessel's waterlight was not operational and was
not attached to ring life buoy. Make waterlight
serviceable and attached to ring life buoy.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 1 November 2021
Resolved
On a vessel of more than 65 feet in length, the minimum
capacity of the fire pump must be 50 gallons per minute
at a pressure of not less than 60 psi at the pump
outlet. Vessel's fire pump was operating at 35 psi at
the pump gauge. Make pump satisfactory to attending
Marine Inspector.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 1 November 2021
Resolved
All machinery and equipment must be installed and
maintained in such a manner as to afford adequate
protection from causing fire, machinery failure
and personnel injury. Vessel's bilge pump belt was loose
and began smoking. replace or repair belt to avoid
hazardous conditions mentioned above.
10 - Safety of Navigation › N/A - No Subsystem › Charts
Issued 1 November 2021
Resolved
As appropriate for the intended voyage, a vessel must
carry adequate and up-to-date charts of large enough
scale to make safe navigation possible. Vessel's chart
was not up-to-date. Provide current/corrected charts
for operational areas.
04 - Emergency Systems › N/A - No Subsystem › Muster list
Issued 1 November 2021
Resolved
The master and crew of a vessel will be familiar with
the content of and have mounted at the operating
station, emergency instructions containing the actions
to be taken in the event of fire, heavy weather, or man
overboard conditions. Except when in the judgment of the
cognizant OCMI the operation of a vessel does not
present one of the hazards listed, the emergency
instruction placard should contain at least the
applicable portions of the “Emergency Instructions”
listed in §185.512. The emergency instructions must be
designed to address the particular equipment,
arrangement, and operation of each individual vessel.
Emergency instruction covering fire aboard vessel is not
addressed. Vessel must update emergency procedures as
addressed during vessel's annual inspection to address
the particular equipment, arrangement, and operation of
the vessel.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 1 November 2021
Resolved
The owner, charterer, master or managing operator shall
instruct each crew member, upon first being employed and
prior to getting underway for the first time on a
particular vessel and at least once every three months,
as to the duties that the crew member is expected to
perform in an emergency including, but not limited to,
the emergency instructions listed on the emergency
instruction placard required by 46 CFR 185.510. Training
shall be logged and include: date of the training; and
general description of the training topics. Moving
forward ensure this instruction is being conducted as
required.
10 - Safety of Navigation › N/A - No Subsystem › Charts
Issued 1 November 2021
Resolved
As appropriate for the intended voyage, a vessel must
carry adequate and up-to-date: U.S. Coast Pilot or
similar publication; Coast Guard Light List; tide
tables; and crrent tables. Publications were not
available for inspection. Make publications (electronic)
available for inspection.
11 - Life Saving Appliances › N/A - No Subsystem › Other (life saving)
Issued 1 November 2021
Resolved
Each survival craft on a vessel must be inspected
monthly, using the manufacturer's instructions to make
sure it is complete and in good order. Survival craft
not being inspected as per regulations. Begin inspecting
survival craft as required and document to show
compliance.
11 - Life Saving Appliances › N/A - No Subsystem › Other (life saving)
Issued 1 November 2021
Resolved
The master of the vessel shall ensure that each EPIRB
must be tested monthly, using the integrated test
circuit and output indicator, to determine that it is
operative. The EPIRB test shall be logged. Moving
forward, test EPIRB and log as required.
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 1 November 2021
Resolved
Electrical equipment on a vessel must be installed and
maintained to protect passengers, crew, other persons,
and the vessel from electrical hazards, including fire,
caused by or originating in electrical equipment, and
electrical shock. Dead-end wires found under operating
station. Remove/make wire in compliance with regulations
to satisfaction of attending Marine Inspector.
07 - Fire Safety › N/A - No Subsystem › Fixed fire extinguishing installation
Issued 9 February 2021
Resolved
A FIXED FIRE EXTINGUISHING SYSTEM ABOARD A VESSEL MUST BE APPROVED BY THE COMMANDANT AND BE CUSTOM ENGINEERED TO MEET THE REQUIREMENTS FOUND IN 46 CFR 181.410. A STORAGE CYLINDER FOR A FIXED FIRE EXTINGUISHING SYSTEM MUST BE INSTALLED AT LEAST 2 INCHES BETWEEN THE DECK AND THE BOTTOM OF THE STORAGE CYLINDER. CYLINDERS MUST BE TESTED BY A CG APPROVED FACILITY AT LEAST EVERY 12 YEARS. MI DISCOVERED THAT THE CO2 STORAGE CYLINER IN THE LAZARETTE SPACE WAS ON THE DECK RESULTING IN A SIGNIFICANT AMOUNT OF CORROSION FOUND ON THE BOTTOM PORTION OF THE CYLINDER. LAST KNOWN SERVICE DATE STAMPED ON THE LAZARETTE'S CO2 CYLINDER WAS DEC 2007. VESSEL MUST PROPERLY ARRANGE CYLINDER AND HAVE REQUIRE TESTS/INSPECTIONS PERFORMED ON THIS DEVICE OR PROVIDE PLAN TO REPLACE WITH ACCEPTABLE SYSTEM. VESSEL MAY OPERATE PER COI PROVIDING LAZARETTE GENERATOR IS NOT USED (VESSEL HAS SEPARATE GENERATOR IN ENGINE ROOM) UNTIL CORRECTED.
07 - Fire Safety › N/A - No Subsystem › Fire-dampers
Issued 3 September 2020
Resolved
Prove proper operation of engine room and lazerette fire dampers.
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 3 September 2020
Resolved
Prove proper operation or provide a 3rd party report of a functionality test of the CO2 systems in the E/R and LAZ.
05 - Radio Communications › N/A - No Subsystem › VHF EPIRB
Issued 3 September 2020
Resolved
Replace battery on EPIRB or provide a new EPIRB with NOAA registration.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 3 September 2020
Resolved
Provide current alcohol swabs.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 3 September 2020
Resolved
Provide 35 adult PFD's with lights & 06 children PFD's with lights.
09 - Working and Living Conditions › 091 - Living Conditions › Medical Equipment
Issued 20 November 2019
Resolved
First aid kit contained expired items. Provide complete and current first aid kit.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 20 November 2019
Resolved
Provide alcohol testing devices for all crew.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 20 November 2019
Resolved
Provide passenger count ashore.
05 - Radio Communications › N/A - No Subsystem › Satellite EPIRB 406MHz/1.6GHz
Issued 20 November 2019
Resolved
Conduct EPIRB testing monthly.
04 - Emergency Systems › N/A - No Subsystem › Public address system
Issued 20 November 2019
Resolved
Provide public address speakers for all passenger areas.
09 - Working and Living Conditions › 091 - Living Conditions › Water, pipes, tanks
Issued 19 February 2019
Resolved
Hole was found in a fresh water system for the aft head in the flexible hose right after the pipe penetrated the bulk head and entered the engine room. Flexible hose must be replaced with approved flexible hose.
46 CFR 177.01-1
05 - Radio Communications › N/A - No Subsystem › VHF radio installation
Issued 27 November 2018
Resolved
Provide GPS position on VHF-DSC radio.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 27 November 2018
Resolved
Replace white 24" lifering with orange 24" lifering.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 27 November 2018
Resolved
Renew grab lines on liferings.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 27 November 2018
Resolved
Provide 60' of bouyant line and bracket for lifering light.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 27 November 2018
Resolved
Provide 12 additional type I adult lifejackets for a total of 65; vessel restricted to 53 persons.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 27 November 2018
Resolved
Properly mark lifejacket storage locations.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 27 November 2018
Resolved
Relocate/switch galley and bridge extinguishers to correct size.
Fire Fighting › Fixed CO2 Fire Extinguishing System › Servicing
Issued 19 October 2016
Resolved
Prior to ops with passengers, ensure all f/f equipment is professionally serviced and provide servicing report to USCG MI for review/approval.
Operations/Management › Drug and Alcohol Testing › Testing, Pre-employment
Issued 19 October 2016
Resolved
Prior to ops with passengers, provide negative pre-employment drug test result for Master.
Communications › Radio Communications › VHF Radiotelephone
Issued 19 October 2016
Resolved
Install/prove proper operation of VHF-DSC (Class D).
Operations/Management › Drug and Alcohol Testing › Employee Coverage
Issued 19 October 2016
Resolved
Provide updated drug testing crew list.
Lifesaving › Inflatable Liferafts › Servicing
Issued 19 October 2016
Resolved
Service liferaft NLT 30NOV16
Lifesaving › Inflatable Liferafts › Hydrostatic Release Unit
Issued 19 October 2016
Resolved
Install new hydro release for liferaft NLT 31OCT16
Personnel › Certificates/Documents/Licenses › License, GMDSS Radio Operator
Issued 19 October 2016
Resolved
Provide FCC Marine Radio Operator Permit for Master.
Lifesaving › Lifebuoys › Markings (ship name/port)
Issued 19 October 2016
Resolved
Re-stencil vessel name on ring buoy
Lifesaving › Lifejacket/PFD (Type I) › Marking
Issued 19 October 2016
Resolved
Stencli vessel name on (01) Type I PFD
Lifesaving › Lifebuoys › Quantity
Issued 19 October 2016
Resolved
Provide (01) USCG-approved 24" orange ring buoy.
Lifesaving › Inflatable Buoyant Apparatus › Weak Link
Issued 19 October 2016
Resolved
Re-rig IBA painter/weak link configuration.
Lifesaving › Lifejacket/PFD (Type I) › Lights
Issued 19 October 2016
Resolved
Provide battery for (01) personal marker light.
Accommodation/Occupational Safety › Occupational Safety › Deck Rail
Issued 7 October 2015
Resolved
46 CFR 177.900(d)(1): Modify port & stbd deck rails to that height of top rails are at least 39.5 inches high as measured from the deck.
Accommodation/Occupational Safety › Occupational Safety › Deck Rail
Issued 7 October 2015
Resolved
Ensure compliance with restriction on passenger access to bow as required by condition of operation on COI.
Documentation › Certificates/Documents › Stability Letter
Issued 8 September 2015
Resolved
Post current stability letter.
Communications › Radio Communications › EPIRB
Issued 8 September 2015
Resolved
Replace EPIRB hydro release by 01NOV15
Documentation › Logs/Records › Logbook/Record (unofficial)
Issued 8 September 2015
Resolved
Log drills & lifesaving equipment checks.
Fire Fighting › Fixed CO2 Fire Extinguishing System › Servicing
Issued 8 September 2015
Resolved
Schedule firefighting equipment servicing to coincide with deficiency check.
Fire Fighting › Fixed Fire Detection System › UL 217 Approval
Issued 8 September 2015
Resolved
Replace 02 smoke detectors with UL-approved RV-type units.
Fire Fighting › Fire Main › Condition
Issued 8 September 2015
Resolved
Replace corroded section of fire main piping in E/R
Fire Fighting › Combustible Materials › Insulation
Issued 8 September 2015
Resolved
Remove lube oil-soaked insulation under stbd generator.
Electrical › Electrical Distribution System (service) › Junction Box
Issued 8 September 2015
Resolved
Replace electrical junction box below stbd generator
Electrical › Electrical Distribution System (service) › Outlet Box
Issued 8 September 2015
Resolved
Secure loose receptacle at forward bulkhead stbd.
Electrical › Lighting (service) › Lighting Fixture
Issued 8 September 2015
Resolved
E/R: remove portable fluorescent light/wire from E/R.
Electrical › Electrical Distribution System (service) › Wiring
Issued 8 September 2015
Resolved
Ensure E/R overhead electrical witing is supported at 24" intervals w/ metallic hangers.
Electrical › Electrical Distribution System (service) › Wiring
Issued 8 September 2015
Resolved
Laz: remove dead-end wiring.
Accommodation/Occupational Safety › Occupational Safety › Guards for Exposed Hazards
Issued 8 September 2015
Resolved
Secure belt guard on port main engine.
Accommodation/Occupational Safety › Occupational Safety › Hand Grab
Issued 8 September 2015
Resolved
Adjust dogs on forward e-escape hatch.
Construction/Loadline › Structures › Door
Issued 5 October 2010
Resolved
Prove proper installation of engine room forward bulkhead watertight door.
Electrical › Electrical Distribution System (service) › Junction Box
Issued 5 October 2010
Resolved
Make proper repairs to electrical junction box for gray water sump pump
Operations/Management › Drug and Alcohol Testing › Proof of Enrollment
Issued 5 October 2010
Resolved
Prove enrollment in DOT testing program
Engineering › Bilge Water Management System › Strainer
Issued 5 October 2010
Resolved
Install larger bilge suction strainers on all bilge lines
Engineering › Fuel Oil Service System › Hose
Issued 5 October 2010
Resolved
Make proper repairs to leaking rescue boat fuel line
Construction/Loadline › Hull › Side Shell
Issued 24 March 2009
Resolved
Remove wood in fpk to prevent poultice corrosion.
Electrical › Electrical Distribution System (service) › Wiring
Issued 24 March 2009
Resolved
Wire in overhead of fpk chafing - install chafing gear.
Construction/Loadline › Hull › Hull Plating
Issued 24 March 2009
Resolved
Crew qtrs and E/R - clean bilges thoroughly.
Pollution Prevention/Response › Prevention Equipment › Marine Sanitation Device, Type III
Issued 24 March 2009
Resolved
Discontinue two unused sewage overboard valves.
Construction/Loadline › Hull › Side Shell
Issued 24 March 2009
Resolved
Begin removing pegboard from E/R sideshell a laz - begin at bottom, working up about 3 ft.
Communications › Radio Communications › EPIRB
Issued 6 January 2009
Resolved
Prior to ops >3NM replace EPIRB hydro release.
Communications › Alarms/Indicators › Bilge Alarm
Issued 6 January 2009
Resolved
Repair audible alarm for hi-water E/R bilge alarms.
Engineering › Fuel Oil Service System › Piping
Issued 6 January 2009
Resolved
Replace flex fuel hose in E/R with appropriate hoses iaw G-MSE Policy Ltr (provided).
Documentation › Certificates/Documents › Certificate of Inspection
Issued 6 January 2009
Resolved
Post all pages of COI in view of psgrs.
Electrical › Electrical Distribution System (service) › Wiring
Issued 6 January 2009
Resolved
Trace/replace lamp-cord-grade wiring in laz.
Operations/Management › Bilge/Bilge System Management › Control of Oil Mixtures
Issued 6 January 2009
Resolved
Determine source of oil leak from laz genset and make repairs.
Communications › Alarms/Indicators › Bilge Alarm
Issued 6 January 2009
Resolved
ID and label unknown alarm panel switch.
Navigation › Piloting/Steering › Marine Charts
Issued 6 January 2009
Resolved
Provide Chart No. 18703
Construction/Loadline › Hull › Bottom Plating
Issued 6 January 2009
Resolved
Re-stow anchor chain to avoid contact w/aluminum hull
Fire Fighting › Means of Escape › Blocked
Issued 6 January 2009
Resolved
Make forward e-escape hatch closure operable from both sides.
Engineering › Sea-water System (primary cooling) › Piping
Issued 6 January 2009
Resolved
Raw water cooling supply to E/R genset: replace two hoses and hose clamps.
Engineering › Sea-water System (primary cooling) › Piping
Issued 6 January 2009
Resolved
MDE c/w discharge piping: replace corroded piping and all painted hose sections.
Navigation › Collision/Grounding Avoidance › Navigation Lights
Issued 6 January 2009
Resolved
Prior to ops > hbr, install mast head light and anchor light meeting UL 1104 for vessels >65'.
Lifesaving › Inflatable Liferafts › Servicing
Issued 16 November 2007
Resolved
Service L/R and provide report. Vessel is restricted to L/B/S route until servicing report are provided.
Lifesaving › Lifejacket/PFD (Type I) › Condition
Issued 16 November 2007
Resolved
Provide 3 adult L/Js.
Electrical › Electrical Distribution System (service) › Circuit Breaker
Issued 16 November 2007
Resolved
Provide cover to exposed breakers in the E/R and laz.
Electrical › Electric Supply System (service) › Battery Installation
Issued 16 November 2007
Resolved
Provide 2 new battery box in the laz.
Documentation › Logs/Records › Drug Test Records
Issued 16 November 2007
Resolved
Provide year end summary for drug testing/program summary.
Engineering › Freshwater Generation System › Valve, Dump
Issued 6 October 2005
Resolved
Provide valve handle IWO port side potable water discharge (O/B valve).
Accommodation/Occupational Safety › Other Accommodation Spaces › Open Deck Space
Issued 6 October 2005
Resolved
Label emergency escape exit via FWD berthing and main cabin aft.
Engineering › Sea-water System (primary cooling) › Valve
Issued 6 October 2005
Resolved
Provide O/B valve handle IWO O/B discharge.
Accommodation/Occupational Safety › Occupational Safety › Rubbish/Waste Materials
Issued 6 October 2005
Resolved
Provide house keeping in area of lazarett.
Engineering › Bilge Water Management System › Hose
Issued 6 October 2005
Resolved
Replace O/B discharge hose in the E/R.
Personnel › Manning/Qualifications › CPR Certified Personnel
Issued 6 October 2005
Resolved
Provide CPR certification for 50% of the crew.
Stability › Watertight Integrity › General
Issued 6 October 2005
Resolved
Repair pilot house light indicator for the E/R watertight door.
Lifesaving › Lifejacket/PFD (General) › Lights
Issued 2 August 2005
Resolved
Provide lights for 09 lifejackets.
Lifesaving › Lifejacket/PFD (General) › Quantity
Issued 2 August 2005
Resolved
Provide 1 child size lifejacket.
Fire Fighting › Ventilation Systems › Duct Hatches
Issued 2 August 2005
Resolved
Make lazarette ventilation duct hatch vapor tight.
Accommodation/Occupational Safety › Medical/First Aid › Medicine Chest
Issued 2 August 2005
Resolved
Replace Aspirin in medical kit.
Construction/Loadline › Hull › Weld
Issued 21 July 2005
Resolved
Repair cracked weld in FWD Peak (Anchor Locker) STBD side aft, middle frame.
Accommodation/Occupational Safety › Occupational Safety › Deck Rail
Issued 21 July 2005
Resolved
Install missing screws in handrail, port side FWD of AFT door.
Communications › Radio Communications › EPIRB
Issued 24 May 2004
Resolved
Provide proof of renewal for the EPIRB hydrostatic release renewal.
Engineering › Sea-water System (primary cooling) › Piping
Issued 24 May 2004
Resolved
Replace raw water hose for the aft ship service generator inway of muffler.
Engineering › Fuel Oil Service System › Hose
Issued 24 May 2004
Resolved
Replace F/O hose between F/O pump and racor F/O filter. 46 CFR 182.720.
Electrical › Electric Supply System (service) › Cable
Issued 24 May 2004
Resolved
Submit plans for replacement of starting battery cables on the aft generator.
Accommodation/Occupational Safety › Medical/First Aid › Medicine Chest
Issued 24 May 2004
Resolved
Replace expired contents of first aid kit.
Communications › Alarms/Indicators › Bilge Alarm
Issued 24 May 2004
Resolved
Provide label for the lazarette bilge alarm indicator.
Lifesaving › Lifejacket/PFD (General)
Issued 14 August 2003
Resolved
Provide on 7 child size life jackets. LEGACY COMPONENT DESC: Condition
Personnel › Certificates/Documents/Licenses
Issued 14 August 2003
Resolved
Provide proof of application for FCC marine radio operators permit.
Operations/Management › Drills/Instruction
Issued 14 August 2003
Resolved
Perform satisfactory man overboard and fire drills.
Fire Fighting › Fire Pumps
Issued 14 August 2003
Resolved
Provide proof of fire pump operation.
Lifesaving › Lifebuoys
Issued 14 August 2003
Resolved
Renew batteries in ring buoy float light. LEGACY COMPONENT DESC: Self-igniting Lights
Navigation › Piloting/Steering
Issued 14 August 2003
Resolved
Provide current coast pilot. LEGACY COMPONENT DESC: US Coast Pilot
Communications › Alarms/Indicators › Bilge Alarm
Issued 14 August 2003
Resolved
Reconnected cable and test bilge alarm in the fwd passageway void.
Construction/Loadline › Hull
Issued 9 April 2003
Resolved
Make forward peak available for inspection.
Construction/Loadline › Hull
Issued 9 April 2003
Resolved
Spot blast areas of corrosion on vessel for inspection - Make repair proposal on repairing corosion.
Engineering › Fuel Oil Service System
Issued 9 April 2003
Resolved
Renew all non-approved F/O hose throughout the vessel. LEGACY COMPONENT DESC: Hose
Electrical › Electric Supply System (service) › Cable
Issued 9 April 2003
Resolved
Submit repair proposal to renew welding cable in DC voltage system. LEGACY COMPONENT DESC: Battery Conductor
Construction/Loadline › Hull
Issued 9 April 2003
Resolved
open up aft accomodation space for inspection.
Pollution Prevention/Response
Issued 9 April 2003
Resolved
Clean bilges for inspection.
Engineering
Issued 9 April 2003
Resolved
Remove engineroom deck plate for inspection of bilges.
Electrical › Electric Generation Source (service)
Issued 17 May 2002
Resolved
Install Hertz meter(s) for both ships service generators.
Engineering › Diesel Engine (propulsion-direct drive)
Issued 17 May 2002
Resolved
Renew/Replace both main diesel engine front oil seals. LEGACY COMPONENT DESC: Crankshaft
Communications › Internal Communications System
Issued 17 May 2002
Resolved
Make aft deck speakers operational.
Accommodation/Occupational Safety › Medical/First Aid
Issued 17 May 2002
Resolved
Remove/replace expired items in first aid kit. LEGACY COMPONENT DESC: Medicine Chest
Electrical
Issued 17 May 2002
Resolved
Clean battery posts on batteries in lazarette.
Electrical
Issued 17 May 2002
Resolved
Reconnect lose fan wire in lazarette.
Electrical › Electrical Distribution System (service)
Issued 17 May 2002
Resolved
Plug open hole in 32 volt panel in lazarette. LEGACY COMPONENT DESC: Switchboard
Fire Fighting › Portable Dry Chemical Fire Extinguisher
Issued 17 May 2002
Resolved
Replace/renew expired extinguisher located in pilot house. LEGACY COMPONENT DESC: Condition
Lifesaving › Lifejacket/PFD (Type I) › Lights
Issued 17 May 2002
Resolved
Provide lights on all life jackets prior to upgrade to coastwise route.
Lifesaving › Lifebuoys
Issued 17 May 2002
Resolved
Upgrade ring lifebuoys to orange prior to upgrade to coastwise route.
Engineering › Fuel Oil Storage/Transfer System
Issued 17 May 2002
Resolved
Replace/renew fuel vent screens on fuel vent pipes. LEGACY COMPONENT DESC: Vent Pipe
Electrical
Issued 26 May 2000
Resolved
REPLACE IMPROPER WIRE ON 12VDC OUTLET IN CONTROL PANEL IN PILOT HOUSE.
Fire Fighting
Issued 26 May 2000
Resolved
PROVIDE PROPER FIRE EXTINGUISHER BRACKETS THROUGHOUT VESSEL.
Lifesaving
Issued 11 January 2000
Resolved
Port light covers below main deck were installed.
Unknown
Issued 11 January 2000
Resolved
Dead light covers installed
Electrical
Issued 25 May 1999
Resolved
PROVE PROPER OPERATION OF EMERGENCY LIGHTING IN CREW QUARTERS PASSAGEWAY.
Construction/Loadline
Issued 25 May 1999
Resolved
INSTALL CHECK VALVES IN INDIVIDUAL SUCTION LINES.
Construction/Loadline
Issued 25 May 1999
Resolved
INSTALL BILGE HIGH LEVEL ALARM IN LAZERETTE.
Unknown
Issued 25 May 1999
Resolved
INSTALL DEAD LIGHT COVERS ON ALL PORT LIGHTS BELOW THE MAIN DECK.
Engineering
Issued 10 June 1998
Resolved
INSTALL 30X30 MESH IN FUEL VENTS.
Accommodation/Occupational Safety
Issued 10 June 1998
Resolved
STENCIL EMERGENCY ESCAPE INSIDE AND OUTSIDE.
Lifesaving
Issued 10 June 1998
Resolved
PROVIDE AND MOUNT LIFEJACKET DONNING PLACARD
Unknown
Issued 10 June 1998
Resolved
UPDATE EQUIPMENT IN FIRST AID KIT.
Navigation
Issued 10 June 1998
Resolved
PROVIDE COPY OF RADIO OPERATOR PERMIT.
Navigation
Issued 10 June 1998
Resolved
PROVIDE COPY OF EMERGENCY BROADCAST INFORMATION.
Fire Fighting
Issued 10 June 1998
Resolved
REPLACE INOPERATIVE HAND PUMP.
Lifesaving
Issued 5 June 1997
Resolved
PROVIDE AND PROPERLY MOUNT CLASS 1, 406 EPIRB AS REQUIRED BY 46 CFR 180.64.THE VESSEL IS LIMITED TO LAKES, BAYS, AND SOUNDS ROUTE UNTIL THIS REQUIREMENT IS MET THE SATISFACTION OF THE ATTENDING MARINE INSPECTOR.
Documentation
Issued 6 June 1996
Resolved
PROVIDE CURRENT FCC RADIO STATION LICENSE
Fire Fighting
Issued 24 April 1995
Resolved
PROVIDE (1) 1.5" X 50' UL FIRE HOSE. PRIOR TO SAILING.
Engineering
Issued 24 April 1995
Resolved
INSTALL FLAME SCREENS FOR FUEL VENTS ON PORT SIDE, PRIOR TO SAILING.
Documentation
Issued 24 April 1995
Resolved
PROVIED VALID OPERATOR LICENSE.
Electrical
Issued 24 April 1995
Resolved
BLOCK BATTERIES IN ENGINE ROOM.
Documentation
Issued 24 April 1995
Resolved
PROVIDE VALID FCC RADIO OPERATOR PERMIT.
Navigation
Issued 24 April 1995
Resolved
MOUNT PORT/STBD NAVIGATION LIGHTS OR PAINT SCREENS SO SCREENS ARE FLAT BLACK.
Fire Fighting
Issued 24 April 1995
Resolved
LABEL FIRE STATIONS.
Documentation
Issued 24 April 1995
Resolved
PROVIDE VALID FCC RADIO TELEPHONY CERTIFICATE.
Accommodation/Occupational Safety
Issued 20 April 1994
Resolved
PROVIDE MARPOL V PLACARD (GARBAGE/PLASTICS).
Lifesaving
Issued 20 April 1994
Resolved
PROVIDE 3 ADULT LIFE PRESERVERS. VESSEL IS RESTRICTED TO CARRYING A TOTAL OF 62 PERSONS UNTIL CLEARED.
Engineering
Issued 20 April 1994
Resolved
REPLACE ALL FUEL TANK VENT SCREENS WITH 30 X 30 MESH.
Accommodation/Occupational Safety
Issued 20 April 1994
Resolved
REINSTALL VENT FOR POTABLE WATER AND INSTALL BUG SCREEN.
Documentation
Issued 20 April 1994
Resolved
PROVIDE OIL POLLUTION PLACARD.
Fire Fighting
Issued 10 May 1993
Resolved
PROVIDE BRACKETS FOR PORTABLE FIRE EXTINGUISHERS.
Lifesaving
Issued 10 May 1993
Resolved
PROVIDE 6 ORANGE FLARES.
Fire Fighting
Issued 10 May 1993
Resolved
PROVIDE 2 CG APPROVED FIRE NOZZELS.
Lifesaving
Issued 10 May 1993
Resolved
REPLACE RETRO-TAPE ON BUOYANT APPARATUS'.
Lifesaving
Issued 10 May 1993
Resolved
LABEL CHILD PFD STOWAGE LOCKER.
Lifesaving
Issued 10 May 1993
Resolved
PROVIDE 7 ADULT PFD'S. VSL IS RESTRICTED TO CARRYING 55 PASSENGERS UNTIL 7 PFD'S PROVIDED.
Lifesaving
Issued 12 June 1992
Resolved
REPAIR/REPLACE BUOYANT APPARATUS.
Accommodation/Occupational Safety
Issued 12 June 1992
Resolved
MARK HATCH ON VESSEL BOW "ESCAPE HATCH, KEEP CLEAR."
Accommodation/Occupational Safety
Issued 25 June 1991
Resolved
PROVIDE MARPOL V PLACARD._x001C_ _x001C_
Documentation
Issued 25 June 1991
Resolved
PROVIDE WASTE MANAGEMENT PLAN.
Fire Fighting
Issued 25 June 1991
Resolved
PROVIDE SUCTION HOSE FOR PORTABLE FIRE AND BILGE PUMP.
Fire Fighting
Issued 25 June 1991
Resolved
REPLACE FIRE HOSE NOZZLES WITH APPROVED TYPE._x001C_ _x001C_ _x001C_
Documentation
Issued 25 June 1991
Resolved
PROVIDE DOCUMENTATION OF DRUG TESTING PROGRAM.
Fire Fighting
Issued 25 June 1991
Resolved
PROVIDE REMOTE MEANS OF SHUTTING DOWN ENG RM AND LAZARETTE VENTILATION IN THE EVENT OF FIRE OR CO2 RELEASE.
Fire Fighting
Issued 25 June 1991
Resolved
FIT LAZARETTE WITH FIRE DETECTION SYSTEM.
Accommodation/Occupational Safety
Issued 5 April 1990
Resolved
INSTAL EMERGENCY LIGHTING IN FWD PASSENGER AREA. LIGHTING IS TO COME ON AUTOMATICALLY WITH LOSS OF AC POWER AND STAY ON FOR 6 HOURS.
Accommodation/Occupational Safety
Issued 5 April 1990
Resolved
SUBMIT PLANS FOR EMERGENCY LIGHTING INSTALLATION BELOW MAIN DECK (FORWARD AREA) PRIOR TO INSTALLATION FOR MSO APPROVAL.
Construction/Loadline
Issued 5 April 1990
Resolved
OPEN ALL SQUARE NON-METALIC VALVES FOR INSPECTION. PROVE MSD AND OTHER VALVES ARE NOT CONSTRUCTED OF PVC. THIS IS TO BE COMPLETED PRIOR TO COMING OFF DRYDOCK
Construction/Loadline
Issued 5 April 1990
Resolved
PROVIDE COPY OF GUAGING REPORT FOR REVIEW (AND ALSO NEED TO OBTAIN ORIGINALSCANTLINGS) PRIOR TO GOING OFF DRYDOCK.
Lifesaving
Issued 5 April 1990
Resolved
PROVIDE AN ADDITIONAL 6 CHILD PFDS AND 2 ADULT PFDS. UNTIL THESE ARE PROVIDED NO CHILDREN MAY BE CARRIED AND PASSENGERS ARE LIMITED TO 61.
Engineering
Issued 23 June 1989
Resolved
HYDRO TEST WAY-WOOLF WATER HEATING BOILER AT ONE AND A QUARTER TIMES THE MAWP.
Engineering
Issued 23 June 1989
Resolved
INSTALL EMERGENCY FUEL SHUT-OFF VALVE AND REMOTE HANDLE ON AFTMOST FUEL TANK SUPPLY LINE.
Fire Fighting
Issued 24 April 1989
Resolved
PROVIDE COPY OF SERVICE REPORT FOR FIXED AND PORTABLE FIRE EXTINGUISHERS TO OCMI.
Construction/Loadline
Issued 24 April 1989
Resolved
MAKE WATERTIGHT HEAD DISCHARGE PIPE CONDUIT THROUGH BULKHEAD BETWEEN ENGINEROOM AND CREWS QUARTERS.
Lifesaving
Issued 21 April 1987
Resolved
PROVIDE 3 ADULT LIFEPRESERVERS AND 1 CHILDS LIFE PRESERVER. VESSEL IS RESTRICTED TO 60 TOTAL PERSONS ALLOWED AND 6 CHILDREN UNTIL CORRECTED
Documentation
Issued 21 April 1987
Resolved
PROVIDE CURRENT FCC SAFETY RADIOTELEPHONY CERTIFICATE.
Electrical
Issued 16 April 1985
Resolved
PROVIDE COVER FOR JUNCTION BOX PORT SIDE OVERHEAD IN ENGINE ROOM.
Electrical
Issued 16 April 1985
Resolved
PROVIDE RUBBER MATTING FOR ENGINE ROOM ELECTRICAL BOARD.
Documentation
Issued 16 April 1985
Resolved
PROVIDE AND POST EMERGENCY CHECK-OFF LIST.
Lifesaving
Issued 16 April 1985
Resolved
LABEL LIFE JACKET LOCKERS.
Electrical
Issued 16 April 1985
Resolved
PROVIDE BATERY CONTAINER IN LAZERETTE.
Fire Fighting
Issued 16 April 1985
Resolved
PROVIDE OR RESERVICE TWO FIRE EXTINGUISHERS (1) IN FORWARD HEAD AND (2) IN ENGINE ROOM.
Navigation
Issued 16 April 1985
Resolved
PROVIDE NEW "RULES OF THE ROAD" BOOK.
Casualty record · 2
5 December 2005Routine · role: Involved in a Marine Casualty · activity 2548237
5 September 2015Routine · role: Involved in a Marine Casualty · serious marine incident, as classified · 1 dead · activity 5733838
Each line is an incident investigation the Coast Guard recorded with this hull among the vessels involved, with the date and the classification the Coast Guard gave it, and the bridge, lock or dam the investigation names where it names one. Involvement is not fault. The investigation narrative is not published. Source: IIR, through 2026.
Ownership record
The Coast Guard's documentation record for this hull -- the Abstract of Title,
with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National
Vessel Documentation Center, files it here with its date, and every reader of this page gets it.