MAURY USCG vessel records Sign in
← All vessels

COOL CHANGE

COOL CHANGE is a 1983 passenger vessel (inspected). The Coast Guard has recorded 80 inspections since 1983, most recently in July 2023, along with 82 deficiencies — 2 with no resolution recorded — and 2 casualty investigations between 2002 and 2023.

Records from 1983 to 2023. Most recent: inspection, 25 July 2023.

Built
1983
Last inspected
25 July 2023
Documentation
Expired · documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

WDD5844
Flag
UNITED STATES
367164690
Maury page id
psix-54896

Inspections, by type

…with no type recorded12
Years with a record 38 calendar years (1983–2023)
The 80 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

This record may be incomplete: the most recent inspection recorded for this vessel was 3 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 1977.

Documentation record

Registered dimensions (L × B × D)44.9 ft × 16.3 ft × 7.8 ft
Registered tonnagegross 39 / net 31
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderEAST BAY BOAT WORKS INC · HARKERS ISLAND NC, UNITED STATES · built 1983
Hull materialWood
PropulsionDiesel Reduction
Hull shapeShip
Hull configurationMonohull
Hailing portORANGE BEACH, AL
Trade endorsementsCoastwise, unrestricted, Fishery
DocumentationExpired · issued 30 June 2004
Service, as the file records itPassenger (Inspected)
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it39 - Simplified, Gross Ton
31 - Simplified, Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 September 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.

Radio station licence

WDJ5279MMSI 367164690 · active · compulsorily equipped · granted 2 May 2017, expires 2 May 2027
WDD5844MMSI 367164690 · expired · compulsorily equipped · granted 3 February 2007, cancelled 8 April 2017
WCX2125MMSI not assigned · expired · compulsorily equipped · granted 9 May 2000, cancelled 17 March 2007
FCC Universal Licensing System ship-station file of 6 September 2026, matched to this hull on its US Official Number. Status and dates are the file’s own. The licensee is not read from the file and is not shown. A lapsed licence’s MMSI is still the number the vessel transmitted under while it was valid.

Inspection history · 80

25 July 2023 Administrative Inspection · Damage Survey
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 7751915
25 July 2023 Type not recorded
No type recorded · Sector Mobile · USCG Heartland District (CGD-H) · Activity 7775299
28 March 2023 Annual Inspection · Administrative Inspection
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 7658332
22 March 2023 Type not recorded
No type recorded · USCGC STINGRAY (WPB 87305) · USCG Heartland District (CGD-H) · Activity 7655540
7 December 2022 Examination of Repairs · Administrative Inspection · Drydock Exam · Internal Structural Exam · Hull Examination
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 7604486
23 March 2022 Administrative Inspection · Annual Inspection
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 7420544
29 November 2021 In-Service Inspection · Administrative Inspection
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 7358915
23 February 2021 Administrative Inspection · Deficiency Check
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 7144882
13 January 2021 DAPI Audit · Administrative Inspection · Deficiency Check · Examination of Repairs · COI Inspection
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 7124097
9 December 2020 Drydock Exam · Administrative Inspection
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 7109260
3 December 2019 Annual Inspection · Administrative Inspection
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 6866311
16 November 2018 Deficiency Check · Administrative Inspection · Annual Inspection
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 6582252
16 November 2018 Drydock Exam
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 6582253
1 February 2018 Administrative Inspection · Deficiency Check
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 6351862
20 November 2017 Administrative Inspection · Annual Inspection · DAPI Audit
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 6310443
16 May 2017 Deficiency Check
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 6148028
17 February 2017 Annual Inspection · DAPI Audit · Administrative Inspection
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 6090548
28 November 2016 Internal Structural Exam · Administrative Inspection · Hull Examination · Examination of Repairs
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 6048273
11 February 2016 Deficiency Check
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 5813950
12 January 2016 Administrative Inspection
Administrative · Sector Mobile · USCG Heartland District (CGD-H) · Activity 5796014
8 January 2016 DAPI Audit · COI Inspection · Administrative Inspection
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 5794087
7 February 2012 Annual Inspection
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 4242058
19 January 2012 Hull Examination · Internal Structural Exam
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 4228031
7 February 2011 COI Inspection
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 3919951
11 February 2010 Hull Examination
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 3672453
3 December 2009 Drydock Extension
Administrative · Sector Mobile · USCG Heartland District (CGD-H) · Activity 3644697
15 April 2009 Deficiency Check
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 3453259
9 March 2009 Deficiency Check · Annual Inspection
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 3430559
4 October 2008 Type not recorded
No type recorded · USCGC COHO (WPB 87321) · USCG Southeast District (CGD-SE) · Activity 3339716
30 May 2008 Type not recorded
No type recorded · USCGC STINGRAY (WPB 87305) · USCG Heartland District (CGD-H) · Activity 3222869
29 April 2008 Deficiency Check
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 3194508
3 April 2008 Annual Inspection
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 3168933
6 December 2007 Hull Examination · Deficiency Check · Internal Structural Exam
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 3091879
11 April 2007 Deficiency Check
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 2904584
9 March 2007 Annual Inspection
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 2885117
14 February 2006 Deficiency Check · COI Inspection
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 2564318
8 December 2005 Hull Examination
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 2537216
14 September 2005 Damage Survey
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 2492175
22 February 2005 Annual Inspection
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 2297113
12 February 2004 Annual Inspection
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1992791
4 December 2003 Deficiency Check · Hull Examination
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1939292
18 March 2003 Annual Inspection
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1759211
9 November 2002 Type not recorded
No type recorded · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1714419
28 March 2002 Annual Inspection
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1483997
28 March 2002 Simplified Stability Test
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1616747
6 December 2001 Hull Examination
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1370444
17 June 2001 Type not recorded
No type recorded · MSO Mobile · USCG Heartland District (CGD-H) · Activity 93457
10 April 2001 Type not recorded
No type recorded · USCGC COBIA (WPB 87311) · USCG Heartland District (CGD-H) · Activity 1521248
8 March 2001 COI Inspection
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1450584
20 March 2000 Deficiency Check
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1047462
3 February 2000 Re-Inspection
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 815733
7 December 1999 Hull Examination
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1432225
22 March 1999 Plan Review "T" Boat
Administrative · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1350283
10 February 1998 COI Inspection
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1418298
4 January 1998 Re-Inspection
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1416815
2 December 1997 Hull Examination
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1460137
14 February 1997 Re-Inspection
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1448890
15 February 1996 Re-Inspection
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1377606
3 November 1995 Hull Examination
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1453175
21 February 1995 COI Inspection
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1357102
22 February 1994 Re-Inspection
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1165108
26 October 1993 Hull Examination
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 834803
2 March 1993 Deficiency Check
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 839524
26 February 1993 Re-Inspection
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 839654
18 March 1992 Deficiency Check
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1269041
11 February 1992 COI Inspection
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 946667
8 October 1991 Hull Examination
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1251253
30 April 1991 Re-Inspection
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1213499
5 April 1990 Re-Inspection
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1222302
7 March 1990 Hull Examination
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 923264
22 February 1989 Hull Examination · COI Inspection
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1194947
19 April 1988 Re-Inspection · Hull Examination
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1036249
5 May 1987 Re-Inspection
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1024712
20 February 1987 Hull Examination
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1002004
18 February 1986 Credit Drydock · COI Inspection
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1296636
17 April 1985 Type not recorded
No type recorded · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1285952
20 March 1985 Type not recorded
No type recorded · MSO Mobile · USCG Heartland District (CGD-H) · Activity 981674
24 September 1984 Type not recorded
No type recorded · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1282218
15 March 1984 Type not recorded
No type recorded · MSO Mobile · USCG Heartland District (CGD-H) · Activity 975645
4 May 1983 Type not recorded
No type recorded · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1272212

Deficiency record · 82

99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 3 August 2023 No resolution recorded
No repairs or alterations affecting the safety of the vessel or its machinery shall be made unless applicable requirements in this chapter are met. The procedures to be followed in notifying the Coast Guard about vessel repairs vary according to the type of vessel and service in which engaged. Vessel owner/operator notified CG that the vessel suffered damage due to vessel fire. Vessel must make permanent repair/alteration to the satisfaction of the OCMI in accordance with 46 CFR 176.700(a) prior to operating / carriage of passengers.
Condition: Damaged By Earlier Event
Action required: 17 - Rectify deficiencies prior to departure
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 25 July 2023 Resolved
The cognizant OCMI may require that a vessel and its equipment undergo any additional test or inspection deemed reasonable and necessary to determine that the vessel and its equipment are suitable for the service in which they are to be employed. Vessel experienced wheelhouse electrical fire. Vessel is restricted from operating until cleared by Marine Inspector.
Condition: Damaged By Earlier Event
Action required: 17 - Rectify deficiencies prior to departure
Resolved 3 August 2023
Resolution: Deficiency cleared due to new deficiencies being placed on vessel.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 25 July 2023 No resolution recorded
Under the authority if 46 U.S.C. 3313 and 46 U.S.C. 3710, a certificate of inspection issued to a vessel may be suspended or revoked if a vessel is found not to comply with the terms of its certificate or fails to meet a standard required by this chapter. Vessel's COI has been revoked due to vessel being inoperable from fire onboard. A new COI will need to be issued prior to to vessel coming back into service.
Condition: Damaged By Earlier Event
Action required: 17 - Rectify deficiencies prior to departure
07 - Fire Safety › N/A - No Subsystem › Operation of Fire protection systems
Issued 13 April 2023 Resolved
An independent modular smoke detecting unit must meet UL 217 and be suitable for use in recreational vehicles. The two smoke detectors in the accommodation areas were found to be inoperable, replace as necessary. 46CFR181.450
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 27 April 2023
Resolved 20 April 2023
Resolution: Installed new detectors
07 - Fire Safety › N/A - No Subsystem › Fixed fire extinguishing installation
Issued 13 April 2023 Resolved
A vessel on which a pre-engineered fixed gas fire extinguishing system is installed must have the following equipment at the operating station: (1) A light to indicate discharge; (2) An audible alarm that sounds upon discharge; and (3) A means to reset devices used to automatically shut down ventilation systems and engines as required by paragraph (a)(3) of this section. The operating station equipment does not have an audible alarm. 46CFR181.420
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 27 April 2023
Resolved 20 April 2023
Resolution: Installed new audible and visual indicator
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Auxiliary engine
Issued 13 April 2023 Resolved
Each motor must have a nameplate attached to it containing the information required by Article 430 of NFPA 70, and for a motor derated in accordance with paragraph (b)(2) of this section, the derated capacity.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 27 April 2023
Resolved 20 April 2023
Resolution: Attached new nameplate indicating de-rated.
04 - Emergency Systems › N/A - No Subsystem › Water level indicator
Issued 29 January 2021 Resolved
Vessels greater than 26 feet must have an audible and visual alarm at the operating station to indicate a high level bilge water situation. High level bilge audible alarm inoperable. Repair or replace bigle alarms.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 12 February 2021
Resolution: O/O installed new audible and visual alarm indicators in the wheelhouse for high water alarms. Witnessed satisfactory operation.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 29 January 2021 Resolved
Portable fire extinguishers must be installed in a suitable bracket to the satisfaction of the marine inspector. Wheelhouse portable secured to bracket with fishing line due to a broken clip. Repair or replace bracket.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 28 February 2021
Resolved 12 February 2021
Resolution: Observed new portable extinguisher and bracket in the wheelhouse. Servicing tag attached and properly documents the inspection and servicing date.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 29 January 2021 Resolved
Fuel tank vents require 30 x 30 mesh flame screen/arrestor. Found both port and starboard vents without screens. Install screens.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 28 February 2021
Resolved 23 February 2021
Resolution: Photographic evidence of installed flame screens on port and starboard fuel tank vents.
09 - Working and Living Conditions › 091 - Living Conditions › Medical Equipment
Issued 16 November 2018 Resolved
First-aid kit and all of its contents are expired.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 11 December 2018
Resolved 10 December 2018
Resolution: Vsl rep procured new USCG approved first-aid kit.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 16 November 2018 Resolved
Breakers on distribution panles are not labled; label IAW with 46 CFR 183.220(d).
Action required: 16 - Rectify deficiencies w/in 14 days
Due 11 December 2018
Resolved 10 December 2018
Resolution: Vsl rep labled breakers on distribution panel.
Lifesaving › Lifefloat › Floating Electric Waterlight
Issued 28 November 2017 Resolved
Replace expired float light batteries
Condition: Invalid
Action required: 705 - Other - as specified
Due 28 December 2017
Resolved 1 February 2018
Resolution: Batteries renewed.
Construction/Loadline › Structures › Deck Plating
Issued 28 November 2017 Resolved
Repair damaged/soft areas on the forward port and starboard bow deck
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 28 December 2017
Resolved 1 February 2018
Resolution: Damaged areas repaired.
Lifesaving › Lifefloat › Lifeline
Issued 28 November 2017 Resolved
Secure life float life lines, and separate life floats with spacers
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 28 December 2017
Resolved 1 February 2018
Resolution: Life float lines secured. Life floats separated with spacers.
Navigation › Piloting/Steering › Marine Charts
Issued 28 November 2017 Resolved
Vessel needs a current and updated chart
Condition: Invalid
Action required: 705 - Other - as specified
Due 28 December 2017
Resolved 1 February 2018
Resolution: Procured updated chart.
Documentation › Certificates/Documents › Stability Letter
Issued 28 November 2017 Resolved
Install sign to designate crew only area on upper deck
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 28 December 2017
Resolved 1 February 2018
Resolution: Sign installed.
Electrical › Lighting (emergency) › Lighting Fixture
Issued 28 November 2017 Resolved
Install emergency lighting from accomodation space to main deck
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 28 December 2017
Resolved 1 February 2018
Resolution: Adequate emergency lighting installed.
Fire Fighting › Fixed Fire Detection System › Smoke Detectors
Issued 28 November 2017 Resolved
Install smoke detector in accommodation spaces
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 28 December 2017
Resolved 1 February 2018
Resolution: Smoke detectors installed in accommodation spaces.
Communications › Public Address System › Loudspeaker
Issued 28 November 2017 Resolved
Make internal Public Address system audible throughout the accommodation spaces when vessel is operating
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 28 December 2017
Resolved 1 February 2018
Resolution: Public address system made audible throughout the accommodation spaces.
Fire Fighting › Structural - Horizontal Zones › General
Issued 28 November 2017 Resolved
Properly seal aft bulkhead in Engine room
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 28 December 2017
Resolved 1 February 2018
Resolution: Aft bulkhead in engine room sealed.
Stability › Weathertight Integrity › General
Issued 28 November 2017 Resolved
Replace or repair damaged hatches on both port and starboard stowage areas
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 28 December 2017
Resolved 1 February 2018
Resolution: Hatches repaired.
Stability › Watertight Integrity › Weathertight Enclosure
Issued 25 April 2017 Resolved
Repair forward hatch and make work properly.
Action required: 705 - Other - as specified
Due 25 May 2017
Resolved 16 May 2017
Resolution: Fwd hatch was repaired and is fully operational.
Construction/Loadline › Structures › Deck Plating
Issued 25 April 2017 Resolved
Repair deck down in lower compartment where floor is falling thru.
Action required: 705 - Other - as specified
Due 25 May 2017
Resolved 16 May 2017
Resolution: Deck was fully repaired in lower compartment.
Operations/Management › Drug and Alcohol Testing › Recordkeeping
Issued 25 April 2017 Resolved
Need proof of supervisor training.
Action required: 705 - Other - as specified
Due 25 May 2017
Resolved 16 May 2017
Resolution: DAPI supervisory training was provided.
Documentation › Certificates/Documents › FCC SSL
Issued 25 April 2017 Resolved
[withheld — contains personal information; the deficiency system, dates, and resolution status are shown above]
Action required: 705 - Other - as specified
Due 25 May 2017
Resolved 16 May 2017
Resolution: [withheld — contains personal information; the deficiency system, dates, and resolution status are shown above]
Documentation › Manuals/Policy Documentation › Emergency Instructions
Issued 25 April 2017 Resolved
Need emergency broadcast instructions posted.
Action required: 705 - Other - as specified
Due 25 May 2017
Resolved 16 May 2017
Resolution: Emergency broadcast instructions were posted.
Documentation › Manuals/Policy Documentation › Emergency Instructions
Issued 25 April 2017 Resolved
Need emergency instructions posted at operating station.
Action required: 705 - Other - as specified
Due 25 May 2017
Resolved 16 May 2017
Resolution: Emergency instructions were posted.
Documentation › Certificates/Documents › FCC Safety Radiotelephony Certificate
Issued 25 April 2017 Resolved
Update EPIRB and Safety Radiotelephony Certificate to relfect valid call sign.
Action required: 705 - Other - as specified
Due 25 May 2017
Resolved 16 May 2017
Resolution: EPIRB and Safety Radio Telephony Certificate now reflect correct call sign.
Communications › Radio Communications › VHF Radiotelephone
Issued 25 April 2017 Resolved
Need GPS installed on VHF-DSC radio.
Action required: 705 - Other - as specified
Due 25 May 2017
Resolved 16 May 2017
Resolution: GPS was linked to VHF-DSC
Navigation › Collision/Grounding Avoidance › Navigation Lights
Issued 25 April 2017 Resolved
Prove operation of starboard navigation light.
Action required: 705 - Other - as specified
Due 25 May 2017
Resolved 16 May 2017
Resolution: Starboard nav light was fully operational and in compliance with NAVRULES.
Operations/Management › Drug and Alcohol Testing › Testing, Equipment
Issued 2 February 2016 Resolved
Vessel did not have alcohol testing devices onboard. Alcohol testing devices must be obtained if the vessel is away from dock more than two hours. IAW 46 CFR 4.06-15
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 16 February 2016
Resolved 11 February 2016
Resolution: Vessel purchased new alcohol testing strips and had them onboard.
Documentation › Manuals/Policy Documentation › Emergency Instructions
Issued 2 February 2016 Resolved
Vessel's emergency instructions not posted at operating station. Post copy of instructions at operating station. IAW 46 CFR 185.510
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 16 February 2016
Resolved 11 February 2016
Resolution: Vessel provided copy of emergency instructions at operating station.
Deck/Cargo › Mooring/Anchoring › Anchor Shackle
Issued 2 February 2016 Resolved
Vessel's ground tackle was not secured/'moused' (together). Secure ground tackle componants (together). IAW 46 CFR 184.300
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 16 February 2016
Resolved 11 February 2016
Resolution: Vessel secured ground tackle with mousing wire.
Lifesaving › Lifejacket/PFD (Type I) › Lights
Issued 7 February 2011 Resolved
Replace or repair inoperable lights on two life preservers as per 46 CFR 1880.75
Action required: 705 - Other - as specified
Resolved 24 February 2011
Resolution: Replaced inoperable light on life preservers.
Lifesaving › Buoyant Apparatus › Floating Electric Waterlight
Issued 7 February 2011 Resolved
Replace broken waterlight on life float as per 46 CFR 180.175(f)(4).
Action required: 705 - Other - as specified
Resolved 24 February 2011
Resolution: Replaced broken waterlight on lifefloat.
Pollution Prevention/Response › Prevention Equipment › Sewage System Valve
Issued 11 February 2010 Resolved
Replace deteriorated gate valves on forward port side for sewage and sink.
Action required: 705 - Other - as specified
Due 26 February 2010
Resolved 12 January 2016
Resolution: Replaced deteriorated valves with new ball valves.
Engineering › Shafting/Propeller Arrangements › Bearing
Issued 11 February 2010 Resolved
Replace port/stbd strut bearings.
Action required: 705 - Other - as specified
Due 11 March 2010
Resolved 26 February 2010
Resolution: Replaced strut bearings.
Lifesaving › Lifejacket/PFD (General) › Condition
Issued 31 March 2009 Resolved
Replace two rejected lifejackets per 46 CFR 180.71. Vessel shall carry no more than 20 persons on board until cleared.
Action required: 705 - Other - as specified
Due 1 May 2009
Resolved 31 March 2009
Resolution: Two lifejackets were replaced.
Lifesaving › Lifejacket/PFD (General) › Lights
Issued 31 March 2009 Resolved
Replace 14 lifejacket lights that are broken per 46 CFR 180.75. Vessel shall not operate beyond a limited coastwise route until cleared.
Action required: 705 - Other - as specified
Due 1 May 2009
Resolved 31 March 2009
Resolution: Fourteen lifejacket lights were replaced with new lights.
Accommodation/Occupational Safety › Medical/First Aid › Medicine Chest
Issued 31 March 2009 Resolved
Replace expired eyewash in first aid kit per 46 CFR 184.710.
Action required: 705 - Other - as specified
Due 1 May 2009
Resolved 31 March 2009
Resolution: Eyewash was replaced.
Engineering › Sea-water System (primary cooling) › Sea Chest
Issued 31 March 2009 Resolved
Make proper repairs to the leaking raw water strainer on port side main engine per 46 CFR 182.20-10.
Action required: 705 - Other - as specified
Due 1 May 2009
Resolved 15 April 2009
Resolution: Repaired raw water strainer; no leaks detected.
Accommodation/Occupational Safety › Occupational Safety › Guards for Exposed Hazards
Issued 31 March 2009 Resolved
Properly secure the guard on stbd main engine per 46 CFR 182.01-5.
Action required: 705 - Other - as specified
Due 1 May 2009
Resolved 15 April 2009
Resolution: Guard was welded and secured.
Engineering › Bilge Water Management System › Valve
Issued 31 March 2009 Resolved
Provide shut-off valve for bilge overboard on port side per 46 CFR 182.520(e).
Action required: 705 - Other - as specified
Due 1 May 2009
Resolved 15 April 2009
Resolution: Shut-off valve installed in bilge overboard.
Engineering › Steering Gear System › Ram
Issued 31 March 2009 Resolved
Make proper repairs to secure the leak in the steering ram per 182.30-1.
Action required: 705 - Other - as specified
Due 1 May 2009
Resolved 15 April 2009
Resolution: Repairs made to steering gear; no leaks detected.
Engineering › Shafting/Propeller Arrangements › Stern Gland
Issued 31 March 2009 Resolved
Secure excessive leak on port shaft packing gland per 46 CFR 182.10-1.
Action required: 705 - Other - as specified
Due 1 May 2009
Resolved 15 April 2009
Resolution: No leaks detected in shaft packing gland.
Engineering › Shafting/Propeller Arrangements › Shrink-Fit Coupling
Issued 31 March 2009 Resolved
Make repairs to the leaking gudgeon on the port side per 46 CFR 176.800.
Action required: 705 - Other - as specified
Due 1 May 2009
Resolved 15 April 2009
Resolution: No leaks detected in gudgeon.
Communications › Public Address System › Loudspeaker
Issued 3 April 2008 Resolved
Provide and demonstrate proper operation of the public address system as required by 46 CFR 184.610
Action required: 705 - Other - as specified
Due 3 May 2008
Resolved 29 April 2008
Documentation › Certificates/Documents › Construction and Equipment Certificate (DSC)
Issued 3 April 2008 Resolved
Provide a thrid party report for the fixed firefighting system in the engine room as required by 46 CFR 176.810 (b)(2).
Action required: 705 - Other - as specified
Due 3 May 2008
Resolved 29 April 2008
Navigation › Piloting/Steering › Tide/Tidal Current Tables
Issued 3 April 2008 Resolved
Provide tidal current tables as required by 46 CFR 184.420
Action required: 705 - Other - as specified
Due 3 May 2008
Resolved 29 April 2008
Construction/Loadline › Structures › Deck Plating
Issued 6 December 2007 Resolved
Replace deck beam on port side located first beam from clamp in accordance with NVIC 7-95 as per 46 CFR 176.800
Action required: 705 - Other - as specified
Due 6 January 2008
Resolved 13 December 2007
Resolution: Replaced the rotten and loose deck beams in kind with screw fasteners.
Construction/Loadline › Hull › Strut/Cross Tie
Issued 6 December 2007 Resolved
Replace stanchion post on starboard side in aft portion of engine room in vicinity of reduction gear in accordance with NVIC 7-95 in accordance with 46 CFR 176.800.
Action required: 705 - Other - as specified
Due 6 January 2008
Resolved 13 December 2007
Resolution: Replaced the rotten stanchion post with twice the timber and screw fasteners.
Construction/Loadline › Hull › Strut/Cross Tie
Issued 6 December 2007 Resolved
Replace deck beams on starboard side in engine room that are wasted in accordance with NVIC 7-95 as per 46 CFR 176.800.
Action required: 705 - Other - as specified
Due 6 January 2008
Resolved 13 December 2007
Resolution: Replaced the rotten and loose deck beams in kind with screw fasteners.
Stability › Unintentional Flooding › General
Issued 6 December 2007 Resolved
Properly secure strainer for raw water intake for air conditioner unit located in engine room as per 46 CFR 176.800
Action required: 705 - Other - as specified
Due 6 January 2008
Resolved 13 December 2007
Resolution: Secured the strainer with a metal strip screwed into the hull frame.
Documentation › Logs/Records › Logbook/Record (unofficial)
Issued 14 March 2007 Resolved
Provide a lifesaving maintenance record in accordance with 46 CFR 185.702.
Action required: 705 - Other - as specified
Due 14 April 2007
Resolved 11 April 2007
Resolution: 1. Provided a bridge log.
Documentation › Logs/Records › Logbook/Record (unofficial)
Issued 14 March 2007 Resolved
Provide a bridge log in accordance with 46 CFR 185.520.
Action required: 705 - Other - as specified
Due 14 April 2007
Resolved 11 April 2007
Resolution: 2. Provided a lifesaving maintenance record.
Navigation › Piloting/Steering › Marine Charts
Issued 14 March 2007 Resolved
Provide updated charts and Tidal Current Tables in accordance with 46 CFR 184.420.
Action required: 705 - Other - as specified
Due 14 April 2007
Resolved 11 April 2007
Resolution: 4. Provided a new updated chart.
Lifesaving › Hand Flares › Storage
Issued 14 March 2007 Resolved
Properly stow flares in accordance with 46 CFR 185.614.
Action required: 705 - Other - as specified
Due 14 April 2007
Resolved 11 April 2007
Resolution: Stowed the flares in a bright orange watertight container.
Construction/Loadline › Structures › Manhole
Issued 14 March 2007 Resolved
Properly label the emergency means of escape in accordance with 46 CFR 185.606.
Action required: 705 - Other - as specified
Due 14 April 2007
Resolved 11 April 2007
Resolution: The emergency escape was properly labeled.
Lifesaving › Lifefloat › Paddle
Issued 14 March 2007 Resolved
Properly attach the paddles to the lifefloat in accordance with 46 CFR 185.604.
Action required: 705 - Other - as specified
Due 14 April 2007
Resolved 11 April 2007
Resolution: The paddles were properly attached to the life float.
Electrical › Electrical Distribution System (service) › Wiring
Issued 14 March 2007 Resolved
Remove dead end wires in the lazarette forward of the fresh water tank in accordance with 46 CFR 183.340.
Action required: 705 - Other - as specified
Due 14 April 2007
Resolved 11 April 2007
Resolution: The dead end wire was removed.
Engineering › Steering Gear System › Rudder Bearing
Issued 14 February 2006 Resolved
TIghten rudder packing on port rudder as per 46 CFR 182.610
Action required: 705 - Other - as specified
Due 14 February 2006
Resolved 1 March 2006
Resolution: No excess leaking observed.
Engineering › Sea-water System (primary cooling) › Piping
Issued 14 February 2006 Resolved
Replace raw water non-flexible hose for generator with standard SAE J1942 hose as per 46 CFR 182.720.
Action required: 705 - Other - as specified
Due 14 March 2006
Resolved 1 March 2006
Resolution: New J1942 hose installed.
Documentation › Markings/Placards › Capacity Marking
Issued 14 February 2006 Resolved
Mark upper deck for with sign indicating "No Passengers Allowed" as required by 46 CFR 185.602.
Action required: 705 - Other - as specified
Due 14 March 2006
Resolved 1 March 2006
Resolution: Placard posted.
Navigation › Piloting/Steering › Coast Guard Light List
Issued 14 February 2006 Resolved
Provide current CG light list as required by 46 CFR 184.420.
Action required: 705 - Other - as specified
Due 14 March 2006
Resolved 1 March 2006
Resolution: Light list onboard.
Documentation › Certificates/Documents › Stability Letter
Issued 14 February 2006 Resolved
Post stability letter as per 46 CFR176.306
Action required: 705 - Other - as specified
Due 14 March 2006
Resolved 1 March 2006
Resolution: Letter posted.
Accommodation/Occupational Safety › Occupational Safety › Guards for Exposed Hazards
Issued 14 February 2006 Resolved
Install machinery guards on rotating machinery as per 46 CFR 177.960
Action required: 705 - Other - as specified
Due 1 April 2006
Resolved 5 April 2006
Resolution: Received an extension on the due date from 14MAR06 to 01APR06. Guards installed.
Communications › Alarms/Indicators › Bilge Alarm
Issued 14 February 2006 Resolved
Label "bilge high level" indicator light at operating station as per 46 CFR 182.530
Action required: 705 - Other - as specified
Due 14 March 2006
Resolved 1 March 2006
Resolution: Light labeled and found satisfactory.
Engineering › Shafting/Propeller Arrangements › Stern Tube Lubrication/Sealing
Issued 14 February 2006 Resolved
Tighten or renew shaft packing on port and starboard shafts as per 46 CFR 176.802
Action required: 705 - Other - as specified
Due 14 March 2006
Resolved 1 March 2006
Resolution: No excess leaking observed.
Construction/Loadline › Hull
Issued 4 December 2003 Resolved
Replace spacer block on the port and starboard struts in the vicinity of the outboard forward bolts. LEGACY COMPONENT DESC: Bracket
Action required: 701 - Prior to carriage of passengers/cargo
Due 4 December 2003
Resolved 31 December 2003
Resolution: Spacer blocks were replaced.
Construction/Loadline › Hull
Issued 4 December 2003 Resolved
Take measure to reduce amount of angel hair on the port and starboard sides of the engine room, outboard of the engines.
Due 4 January 2004
Resolved 31 December 2003
Resolution: Owner/Operator scrubbed anel hair with brush and applied vinegar to wood.
Documentation
Issued 3 February 2000 Resolved
PROVIDE A VALID RADIO STATION LICENSE AND FCC SAFETY CERTIFICATE AS PER 47 CFR 88.05.
Condition: Unknown
Due 3 February 2000
Resolved 3 February 2000
Accommodation/Occupational Safety
Issued 3 February 2000 Resolved
PROVIDE 12 INCH COURSES IN THE BOW RAIL AS PER 46 CFR 177.900(g)
Condition: Unknown
Due 3 February 2000
Resolved 3 February 2000
Construction/Loadline
Issued 2 December 1997 Resolved
RENEW AS ORIGINAL CHINE BUTT BLOCK LOCATED IN THE ENGINE ROOM PORTSIDE BETWEEN FRAMES 4 AND 5. SEE COAST GUARD NVIC 7-95.
Condition: Unknown
Due 2 December 1997
Resolved 15 December 1997
Construction/Loadline
Issued 2 December 1997 Resolved
RENEW AS ORIGINAL THE FRACTURED FRAME LOCATED IN THE ENGINE ROOM STARBOARD SIDE, THIRD FRAME AFT OF THE FORWARD BULKHEAD. SEE COAST GUARD NVIC 7-95.
Condition: Unknown
Due 2 December 1997
Resolved 15 December 1997
Construction/Loadline
Issued 2 December 1997 Resolved
RENEW WASTED BRONZE THROUGH HULL FITTING LOCATED IN THE ENGINE ROOM PORT SIDE AFT. SEE COAST GUARD NVIC 7-95.
Condition: Unknown
Due 2 December 1997
Resolved 15 December 1997
Construction/Loadline
Issued 2 December 1997 Resolved
RENEW AS ORIGINAL THE FRACTURED GUSSET LOCATED IN THE ENGINE ROOM STARBOARDSIDE FORWARD MOST GUSSET. SEE COAST GUARD NVIC 7-95.
Condition: Unknown
Due 2 December 1997
Resolved 15 December 1997
Construction/Loadline
Issued 2 December 1997 Resolved
RENEW AS ORIGINAL THE WASTED STARBOARD HULL PLANK LOCATED IN WAY OF THE STARBAORD MAIN STRUT. SEE COAST GUARD NVIC 7-95.
Condition: Unknown
Due 2 December 1997
Resolved 15 December 1997
Engineering
Issued 26 February 1993 Resolved
REMOVE PET-COCKS IN PORT AND STARBOARD MAIN ENGINE FUEL FILTERS IAW 46CFR 182.20-40(6)(7).
Condition: Unknown
Due 5 March 1993
Resolved 12 March 1993
Construction/Loadline
Issued 26 February 1993 Resolved
PROVE PROPER OPERATION OF FWD ELECTRIC BILGE PUMP AND ELECTRIC BILGE PUMP IN LAZARETTE.
Condition: Unknown
Due 5 March 1993
Resolved 12 March 1993
Lifesaving
Issued 11 February 1992 Resolved
PROVIDE TWO ADULT LIFE PRESERVERS WITH LIGHTS ATTACHED. UNTIL THESE JACKETS ARE PROVIDED, THE MAXIMUM NUMBER OF PERSONS ALLOWED TO BE CARRIED IS REDUCED TO -20- TOTAL PERSONS.
Condition: Unknown
Due 11 February 1992
Resolved 11 February 1992
Construction/Loadline
Issued 5 May 1987 Resolved
CLOSE IN ALL PERIPHERY VENTS AROUND COCKPIT OR REDUCE ROUTE. VENTING FOR ENGINE ROOM & FUEL TANKS WILL HAVE TO BE SUPPLIED.
Condition: Unknown
Due 5 May 1987
Resolved 5 May 1987
Documentation
Issued 5 May 1987 Resolved
CONDUCT A SIMPLIFIED STABILITY TEST IN THE PRESENCE OF A USCG MARINE INSPECTOR OR REDUCE ROUTE.
Condition: Unknown
Due 5 May 1987
Resolved 5 May 1987

Casualty record · 2

9 November 2002Routine · role: Involved in a Marine Casualty · 1 injured · activity 1714419
25 July 2023Routine · role: Involved in a Marine Casualty · serious marine incident, as classified · activity 7775299
Each line is an incident investigation the Coast Guard recorded with this hull among the vessels involved, with the date and the classification the Coast Guard gave it, and the bridge, lock or dam the investigation names where it names one. Involvement is not fault. The investigation narrative is not published. Source: IIR, through 2026.

Ownership record