MAURY USCG vessel records
← All vessels

WEEKS 303

Built
1964
Last inspected
13 June 1995
Controls
None recorded without a removal date

This record may be incomplete: the most recent inspection recorded for this vessel was 31 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard.

Inspection record

Last inspected 13 June 1995
…with no type recorded3
Operational controls None recorded without a removal date
Years with a record 9 calendar years (1985–1995)
Every line above is a count of records the US Coast Guard wrote, or a date it recorded. A blank resolution means none was recorded in this data; it does not establish that a deficiency is outstanding. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Identity

Flag
UNITED STATES
Tonnage
1140 - Regulatory (Subpart C or D), Gross Ton 1090 - Regulatory (Subpart C or D), Net Ton
Maury page id
psix-54899
Vessel history report
Every record for this hull, in one document — $299

Every recorded inspection, 1972 to 2026, in one chronology · every deficiency, with system, dates and resolution · operational controls imposed and removed · every name this hull has been recorded under · the vessels it was inspected alongside, and when · how its record compares with hulls of similar age and size, as a fact about the population and never a judgement about this vessel.

Read one first, in full: a forty-year chronology · a hull that changed operators four times · the sparse case, shown as an example, not for sale.

This report is in development and is not for sale yet. There is no date, and nothing is charged. Leave an email and we will tell you when it exists, once.

Inspection history · 27

13 June 1995 Administrative
Administrative · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1187225
29 October 1993 Damage Survey
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1356440
8 October 1992 Deficiency Check
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1268854
8 September 1992 Deficiency Check
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1267277
19 August 1992 Deficiency Check
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 957316
27 July 1992 Deficiency Check
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1269730
26 July 1992 Type not recorded
No type recorded · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 140705
24 June 1992 COI Inspection
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 958430
14 May 1992 Deficiency Check
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 944358
16 October 1991 Deficiency Check
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1249912
17 September 1991 Re-Inspection
Physical examination · MSO WILMINGTON · USCG East District (CGD-E) · Activity 936375
20 December 1990 Deficiency Check
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 899848
13 December 1990 Deficiency Check
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 1239547
27 November 1990 Deficiency Check
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1235420
24 September 1990 Hull Examination
Physical examination · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 928615
24 September 1990 Administrative
Administrative · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1269212
27 June 1990 COI Inspection
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 928226
23 February 1988 Hull Examination
Physical examination · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 1010438
16 December 1987 Deficiency Check
Physical examination · MIO PHILADELPHIA · USCG East District (CGD-E) · Activity 1312712
6 October 1987 Type not recorded
No type recorded · MIO PHILADELPHIA · USCG East District (CGD-E) · Activity 1012539
8 September 1987 Deficiency Check
Physical examination · MIO PHILADELPHIA · USCG East District (CGD-E) · Activity 1013585
20 August 1987 Damage Survey
Physical examination · MIO PHILADELPHIA · USCG East District (CGD-E) · Activity 1338076
6 August 1987 COI Inspection
Physical examination · MIO PHILADELPHIA · USCG East District (CGD-E) · Activity 1029471
29 July 1986 Re-Inspection
Physical examination · MSO WILMINGTON · USCG East District (CGD-E) · Activity 1299652
10 January 1986 Examination of Repairs · Damage Survey
Physical examination · MIO PHILADELPHIA · USCG East District (CGD-E) · Activity 994326
1 August 1985 Credit Drydock · COI Inspection
Physical examination · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 1292815
28 June 1985 Type not recorded
No type recorded · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 1291128

Deficiency record · 48

Documentation
Issued 29 October 1993 Resolved
PROVIDE A VALID LOADLINE CERTIFICATE. CURRENT ONE IS EXPIRED AND THERE ARENUMEROUS WATERTIGHT BULKHEAD PENETRATIONS THAT ARE NOT WATERTIGHT.
Condition: Unknown
Due 12 November 1993
Resolved 18 May 2002
Resolution: MISLE Maintenance - Resolved all open deficiencies issued prior to 6/1/1997 where activity was closed and deficiency due date was past
Documentation
Issued 29 October 1993 Resolved
CONDUCT AN INSPECTION FOR CERTIFICATION.
Condition: Unknown
Due 12 November 1993
Resolved 18 May 2002
Resolution: MISLE Maintenance - Resolved all open deficiencies issued prior to 6/1/1997 where activity was closed and deficiency due date was past
Construction/Loadline
Issued 29 October 1993 Resolved
GAS FREE ALL SPACES AND CONDUCT A CREDIT DRYDOCK AND INTERNAL STRUCTURAL EXAM.
Condition: Unknown
Due 12 November 1993
Resolved 18 May 2002
Resolution: MISLE Maintenance - Resolved all open deficiencies issued prior to 6/1/1997 where activity was closed and deficiency due date was past
Unknown
Issued 24 June 1992 Resolved
COMPLETE THE OUTSTANDING WORKLIST ITEMS NO'S E1,E2,E7,E9,E17,E21,E22,D1,D5,D8, AND D9 DATED 24JUN92.
Condition: Unknown
Due 24 June 1992
Resolved 24 June 1992
Engineering
Issued 17 September 1991 Resolved
PROVIDE A SUITABLE RELIEF VALVE WITH HAND RELIEVING GEAR FOR THE DECK AIR TANK.
Condition: Unknown
Due 17 September 1991
Resolved 17 September 1991
Electrical
Issued 17 September 1991 Resolved
MAKE ALL GENERATOR ALARMS OPERABLE.
Condition: Unknown
Due 17 September 1991
Resolved 17 September 1991
Electrical
Issued 17 September 1991 Resolved
MAKE MAIN BREAKER FOR #3 GEN OPERABLE AT SWITCHBOARD.
Condition: Unknown
Due 17 September 1991
Resolved 17 September 1991
Electrical
Issued 17 September 1991 Resolved
MAKE ALL SWITCHBOARD CONTROLS OPERABLE FROM FRONT OF SWITCHBOARD.
Condition: Unknown
Due 17 September 1991
Resolved 17 September 1991
Deck/Cargo
Issued 27 November 1990 Resolved
MAKE THE FOLLOWING REPAIRS TO #7S BALLAST TANK: A) CROP & INSERT UPPER OUTBOARD SECTION OF FWD BULKHEAD IWO FRACTURE (MIN. 2'X2' INSERT) B) COMPLETE WELDING OF UNDERSIDE UPPER SIDESHELL LONG (IWO RENEWAL) C) INSTALLBRACKET ATTACHING UPPER SIDESHELL LONG TO FWD BULKHEAD.
Condition: Unknown
Due 27 November 1990
Resolved 27 November 1990
Construction/Loadline
Issued 24 September 1990 Resolved
RENEW SOUNDING TUBE SUPPORT IN #35 BALLAST TANK.
Condition: Unknown
Due 24 September 1990
Resolved 24 September 1990
Construction/Loadline
Issued 24 September 1990 Resolved
IN #6S BALLAST TNK. RENEW AS ORIGINAL THE; SOUNDING TUBE & THE SUPPORT FIRST S/S LONG. DOWN FRM MAIN DK FRM AFT BLKHD TO FWD OF ACCESS LDR, THE LDR, THE BRACKET ATTACHING THE 2ND S/S LONG. DOWN FRM MAIN DK TO THE AFT BLKHD, THE ENTIRE LENGTH OF 1ST UNDERDECK LONG. INBOARD OF THE S/S.
Condition: Unknown
Due 24 September 1990
Resolved 24 September 1990
Construction/Loadline
Issued 24 September 1990 Resolved
IN #6P BALLAST TNK RENEW AS ORIGINAL THE; SOUNDING TUBE & THE FORWARD MOST S/S VERTICAL WEB FROM ITS BASE TO MARKED SECTION.
Condition: Unknown
Due 24 September 1990
Resolved 24 September 1990
Construction/Loadline
Issued 24 September 1990 Resolved
IN #7S BALLAST TNK RENEW AS ORIGINAL THE; SOUNDING TUBE, THE 1ST S/S DOWN FRM M.D. AS MAKED, MIDDLE BOTTOM TRANSVERSE IN ITS ETIRETY, AND INSTALL THEBRACKET ATTACHING THE 1ST S/S LONG DOWN FROM M.D. TO FWD BLKHD.
Condition: Unknown
Due 24 September 1990
Resolved 24 September 1990
Construction/Loadline
Issued 24 September 1990 Resolved
IN #8S BALLASTING RENEW AS ORIGINAL THE BRACKET TYING THE 3RD S/S LONG DOWNFROM M.D. TO THE FWD BLKHD, PROPERLY WELD THE RENEWED PORTION OF THE #1, 3,5 & 8 INBOARD LONG BLKHD STIFFNERS (#'D FRM FWD BLKHD) TO EXISTING STIFFNERS, REWELD 1ST S/S LONG DOWN FRM M.D. TO THE AFT BLKHD.
Condition: Unknown
Due 24 September 1990
Resolved 24 September 1990
Construction/Loadline
Issued 24 September 1990 Resolved
IN #8P BALLAST TNK RENEW AS ORIG THE SOUNDING TUBE & STRIKER PLATE & FWD BLKHD FLATBAR STIFFNER IN ENTIRETY. PROPERLY WELD THE RENEWED PORTION OF #2,4,7&8 INBOARD LONG BLKHD STIFFNERS (#1D FM FWD BLKHD) TO EXISTING STIFF-NERS, PROPERLY RPR WASTED BTM TRANSVERSE FLANGE PLATE IWO DIAG BTM THE-IN.
Condition: Unknown
Due 24 September 1990
Resolved 24 September 1990
Construction/Loadline
Issued 24 September 1990 Resolved
RENEW MAIN DECK AS ORIGINAL IN THE AFT INBOARD CORNER OF #8S BALLAST TANK AND THE FWD OUTBOARD OCRNER OF THE #8P BALLAST TANK AS MARKED.
Condition: Unknown
Due 24 September 1990
Resolved 24 September 1990
Construction/Loadline
Issued 24 September 1990 Resolved
RENEW AS ORIGINAL THE 32,3 $ 4 SPUD WELL BRACKETS DOWN FROM MAIN DECK IN THE #8P BALLAST TANK.
Condition: Unknown
Due 24 September 1990
Resolved 24 September 1990
Navigation
Issued 27 June 1990 Resolved
PLACE NOT UNJDER COMMAND LTS INTO OPERATION
Condition: Unknown
Due 27 June 1990
Resolved 27 June 1990
Documentation
Issued 27 June 1990 Resolved
PROVIDE LETTER DESIGNATING "PERSON IN CHARGE" OF OIL TRANSFER OPERATIONS
Condition: Unknown
Due 27 June 1990
Resolved 27 June 1990
Lifesaving
Issued 27 June 1990 Resolved
LABEL PFD STORAGE BOX WITH NUMBER OF PERSONS PFD'S
Condition: Unknown
Due 27 June 1990
Resolved 27 June 1990
Fire Fighting
Issued 27 June 1990 Resolved
LABEL CO2 RELEASE/VENT SHUTDOWN PULL BOX
Condition: Unknown
Due 27 June 1990
Resolved 27 June 1990
Fire Fighting
Issued 27 June 1990 Resolved
PROVIDE FIX FIRE RELEASE STATION WITH POSTED OPERATING INSTRUCTION
Condition: Unknown
Due 27 June 1990
Resolved 27 June 1990
Fire Fighting
Issued 27 June 1990 Resolved
POST FIRE CONTROL PLAN
Condition: Unknown
Due 27 June 1990
Resolved 27 June 1990
Fire Fighting
Issued 27 June 1990 Resolved
REPAIR GENERAL ALARM IN UPPER PUMP ROOM
Condition: Unknown
Due 27 June 1990
Resolved 27 June 1990
Documentation
Issued 27 June 1990 Resolved
PROVIDE LETTER TO MSO CERTIFYING THAT COMPANY HAS INSTITUTED DRUG TESTING PROGRAM BY 21DEC90
Condition: Unknown
Due 27 June 1990
Resolved 27 June 1990
Electrical
Issued 27 June 1990 Resolved
TEST ALL DIESEL GENERATORS AND AIR RECEIVERS
Condition: Unknown
Due 27 June 1990
Resolved 27 June 1990
Fire Fighting
Issued 27 June 1990 Resolved
PROVIDE PROPER PAINT LOCKER ON VSL FITTED WITH FIX FIRE EXT SYSTEM
Condition: Unknown
Due 27 June 1990
Resolved 27 June 1990
Navigation
Issued 27 June 1990 Resolved
REPLACE 4 RED GLOBES ON MAST DREDGING L/S
Condition: Unknown
Due 27 June 1990
Resolved 27 June 1990
Fire Fighting
Issued 6 October 1987 Resolved
PROVIDE CG APPROVED NOZZLES FOR 1 1/2" FIREHOSES.
Condition: Unknown
Due 6 October 1987
Resolved 6 October 1987
Lifesaving
Issued 6 October 1987 Resolved
PROVIDE OCEAN SERVICE EQUIPPED LIFERAFT IN LIEU OF LIMITED SERVICE.
Condition: Unknown
Due 6 October 1987
Resolved 6 October 1987
Electrical
Issued 20 August 1987 Resolved
REPAIR/REPLACE LIGHTING FIXTURES AND THEIR WIRING ABOVE GENERATORS IN ENGINEROOM WHICH WERE DESTROYED BY FIRE.
Condition: Unknown
Due 20 August 1987
Resolved 20 August 1987
Electrical
Issued 20 August 1987 Resolved
PRIOR TO VESSEL BEING PLACED BACK IN SERVICE, CONDUCT OPERATIONAL TEST OF ALL 4 GENERATORS IN PRESENCE OF A COAST GUARD MARINE INSPECTOR.
Condition: Unknown
Due 20 August 1987
Resolved 20 August 1987
Fire Fighting
Issued 20 August 1987 Resolved
PRIOR TO VESSEL BEING PLACED BACK IN SERVICE, PROVIDE PROOF THAT ENGINEROOMFIXED CO2 SYSTEM HAS BEEN RECHARGED AND PLACED BACK IN SERVICE.
Condition: Unknown
Due 20 August 1987
Resolved 20 August 1987
Lifesaving
Issued 6 August 1987 Resolved
PROVIDE LIGHTS FOR LIFEJACKETS AND EXPOSURE SUITS.
Condition: Unknown
Due 6 August 1987
Resolved 6 August 1987
Lifesaving
Issued 6 August 1987 Resolved
SERVICE HYDROSTATIC RELEASE FOR LIFERAFT.
Condition: Unknown
Due 6 August 1987
Resolved 6 August 1987
Lifesaving
Issued 6 August 1987 Resolved
STENCIL LIFERINGS AND EXPOSURE SUITS WITH VESSEL NAME.
Condition: Unknown
Due 6 August 1987
Resolved 6 August 1987
Lifesaving
Issued 6 August 1987 Resolved
PROVIDE 12 HAND HELD RED PARACHUTE FLARES.
Condition: Unknown
Due 6 August 1987
Resolved 6 August 1987
Fire Fighting
Issued 6 August 1987 Resolved
PROVIDE USCG APPROVED FIRE HOSE NOZZLES FOR 5 FIRE HOSES.
Condition: Unknown
Due 6 August 1987
Resolved 6 August 1987
Fire Fighting
Issued 6 August 1987 Resolved
PROVIDE FIVE 1 1/2 INCH FIRE HOSES WITH UL LABELS.
Condition: Unknown
Due 6 August 1987
Resolved 6 August 1987
Electrical
Issued 6 August 1987 Resolved
REMOVE CONTROLLERS ON STARBOARD SIDE PUMP ROOM FOR AUTOMATIC GREASING SYSTEM.
Condition: Unknown
Due 6 August 1987
Resolved 6 August 1987
Accommodation/Occupational Safety
Issued 6 August 1987 Resolved
RESECURE SERVICE AIR GAUGE STARBOARD AIR TANK.
Condition: Unknown
Due 6 August 1987
Resolved 6 August 1987
Accommodation/Occupational Safety
Issued 6 August 1987 Resolved
INSTALL NEW RELIEVE VALVES FOR AIR RECEIVERS AND TEST IN PRESENCE OF MARINE INSPECTOR.
Condition: Unknown
Due 6 August 1987
Resolved 6 August 1987
Accommodation/Occupational Safety
Issued 6 August 1987 Resolved
CONDUCT HYDROSTATIC TEST OF BOTH AIR RECEIVERS IN PRESENCE OF MARINE INSPECTOR.
Condition: Unknown
Due 6 August 1987
Resolved 6 August 1987
Documentation
Issued 6 August 1987 Resolved
PROVIDE OIL TRANSFER PROCEDURES AS PER 33 CFR 155.720.
Condition: Unknown
Due 6 August 1987
Resolved 6 August 1987
Documentation
Issued 6 August 1987 Resolved
PROVIDE COPY OF LIFERAFT AND FIRE EXTINGUISHER SERVICING REPORTS.
Condition: Unknown
Due 6 August 1987
Resolved 6 August 1987
Documentation
Issued 6 August 1987 Resolved
PROVIDE COPY OF IOPP CERTIFICATE FORM A.
Condition: Unknown
Due 6 August 1987
Resolved 6 August 1987
Documentation
Issued 29 July 1986 Resolved
CERTFICATE OF DOCUMENTATION TO BE ENDORSED FOR COASTWISE.
Condition: Unknown
Due 29 July 1986
Resolved 29 July 1986
Construction/Loadline
Issued 10 January 1986 Resolved
MAKE PROPER REPAIRS TO COLLISION DAMAGE TO MAIN DECK, SIDE SHELL AND BOTTOMIN WAY OF #4 BALLAST TANK PORT SIDE.
Condition: Unknown
Due 10 January 1986
Resolved 10 January 1986

Source. US Coast Guard records through 23 August 2026, retrieved 5 September 2026. Vessels the Coast Guard classes as Barge or Towing Vessel. Coverage and known gaps.

Maury does not score, rate, or grade vessels. What Maury does not do · Glossary · Correct a record.