MAURY USCG vessel records Sign in
← All vessels

CARL F THORNE

CARL F THORNE is a 1983 offshore supply vessel. The Coast Guard has recorded 55 inspections since 1983, most recently in April 2016, along with 66 deficiencies — 1 with no resolution recorded —.

Records from 1983 to 2016. Most recent: inspection, 5 April 2016.

Built
1983
Last inspected
5 April 2016
Documentation
No Operation - PM · documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

8216370 View on MarineTraffic leaves Maury; a third-party site, nothing from it is stored here
WDB3673
Flag
UNITED STATES
366623000 (licence lapsed)
Maury page id
psix-54901

Inspections, by type

…with no type recorded7
…past their stated due date1
Years with a record 29 calendar years (1983–2016)
The 55 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

This record may be incomplete: the most recent inspection recorded for this vessel was 10 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Offshore class in Maury's sources begin in 1978.

Documentation record

Registered dimensions (L × B × D)195.9 ft × 52.0 ft × 10.0 ft
Registered tonnagegross 455 / net 309
ITC dimensions (L × B × D)199.7 ft × 52.0 ft × 24.0 ft
ITC tonnagegross 1,788 / net 536
BuilderHALTER MARINE INC · NEW ORLEANS, LA, UNITED STATES · built 1983
Hull materialSteel
PropulsionDiesel Electric
Hull shapeNot recorded
Hull configurationNot recorded
Hailing portNEW ORLEANS, LA
Trade endorsementsCoastwise, unrestricted, Registry
DocumentationNo Operation - PM · issued 30 June 2004
Service, as the file records itOffshore Supply Vessel
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it455 - Regulatory (Subpart C or D), Gross Ton
1788 - Convention (Subpart B), Gross Ton
309 - Regulatory (Subpart C or D), Net Ton
536 - Convention (Subpart B), Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 September 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.

Radio station licence

WDB3673MMSI 366623000 · expired · compulsorily equipped · granted 7 February 2013, cancelled 15 July 2023
WCE4006MMSI 366623000 · expired · compulsorily equipped · granted 14 July 1994, cancelled 26 September 2004 · licensed under a name not among this hull’s recorded names (not shown)
FCC Universal Licensing System ship-station file of 6 September 2026, matched to this hull on its US Official Number. Status and dates are the file’s own. The licensee is not read from the file and is not shown. A lapsed licence’s MMSI is still the number the vessel transmitted under while it was valid.

A report is not offered for this hull: Its record holds only 2 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. Reports.

Inspection history · 55

5 April 2016 Administrative Inspection
Administrative · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 5876242
29 August 2011 Administrative Inspection
Administrative · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 4129824
11 July 2011 Construction Oversight · Damage Survey · Annual Inspection · Examination of Repairs
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 4078836
11 May 2009 Annual Inspection · Administrative Inspection · Ballast Water Examination · MARPOL Annex IV Survey · MTSA Verification
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 3472047
29 April 2009 Examination of Repairs
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 3463670
30 May 2008 Cargo Tank Internal · COI Inspection · Internal Structural Exam · MTSA Verification · Drydock Exam
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 3179063
9 October 2007 Administrative Inspection · Annual Inspection
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 3097574
7 August 2006 Administrative Inspection · Examination of Repairs
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 2738381
1 June 2006 Internal Structural Exam · Hull Examination · Cargo Tank Internal · MTSA Verification · Annual Inspection
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 2641155
28 July 2005 Examination of Repairs · COI Inspection · MTSA/ISPS Verification · MARPOL Annex I Examination
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 2443880
12 July 2004 Administrative Inspection
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 2130272
18 June 2004 MTSA/ISPS Verification
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 2107086
7 June 2004 Re-Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 2091044
29 December 2003 Security Plan Review - VSP
Administrative · Marine Safety Center (MSC) · Activity 1976346
7 May 2003 Deficiency Check
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 1788502
10 February 2003 Hull Examination · Annual Inspection · Internal Structural Exam
Physical examination · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1740788
1 July 2002 Administrative Inspection · Re-Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 1639374
28 March 2001 Re-Inspection · Hull Examination
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1406886
14 September 2000 Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 146638
5 May 2000 COI Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1468570
9 July 1999 Administrative
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1093225
29 June 1999 Re-Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1098424
5 May 1998 COI Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1408128
29 January 1998 Hull Examination
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1406251
4 January 1998 Administrative
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 784042
7 July 1997 Examination of Repairs · Damage Survey · Re-Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1441278
19 June 1996 Deficiency Check
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 885867
3 May 1996 COI Inspection · Hull Examination
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1459992
1 February 1996 Initial Construction-Excluding Oversight · Inclining Experiment
Physical examination · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1400280
18 July 1995 Administrative
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1186311
27 April 1995 Re-Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1431523
13 June 1994 Administrative
Administrative · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 1016644
28 April 1994 Hull Examination · COI Inspection
Physical examination · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 857717
4 January 1994 Administrative
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1464495
21 December 1993 Administrative
Administrative · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 849557
10 February 1993 Hull Examination · COI Inspection
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1359478
6 April 1992 Deficiency Check
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 943533
27 February 1992 Re-Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1010137
29 October 1991 Administrative
Administrative · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1252262
11 July 1991 Deficiency Check
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1246070
29 March 1991 COI Inspection · Hull Examination
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 927625
6 September 1990 Deficiency Check
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1217950
29 June 1990 Deficiency Check
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1223713
10 May 1990 Re-Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 929323
1 September 1989 Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1346407
31 March 1989 COI Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1196560
28 April 1988 Re-Inspection · Deficiency Check · Hull Examination
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1345224
10 November 1987 Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1333049
7 April 1987 COI Inspection
Physical examination · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1006770
3 July 1986 Re-Inspection
Physical examination · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1292740
20 March 1986 Deficiency Check
Physical examination · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 998548
4 June 1985 Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1285981
3 May 1985 Type not recorded
No type recorded · MSO Mobile · USCG Heartland District (CGD-H) · Activity 980891
2 August 1984 Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 974309
5 May 1983 Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 969814

Deficiency record · 66

Lifesaving › Rescue Boat › Carriage Requirement
Issued 13 July 2011 Resolved
Weigh rescue boat using certified scale in presence of marine inspector.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 3 August 2011
Lifesaving › Launching Appliances › Davit
Issued 13 July 2011 Resolved
Supply plans for davit installation to OCMI/class. OCMI/class to verify structure support is installed IAW plans.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 1 August 2011
Lifesaving › Launching Appliances › Davit
Issued 13 July 2011 Resolved
Conduct static/dynamic test on rescue boat davit in presence of OCMI.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 3 August 2011
Lifesaving › Launching Appliances › Davit
Issued 13 July 2011 Resolved
Conduct NDT test on davit deck plate following static/dynamic test. OCMI to witness test.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 3 August 2011
Construction/Loadline › Structures › Deck Plating
Issued 13 July 2011 Resolved
C/R to original entire chain locker deck within 18 inches of aft bulkhead and sideshell. Conduct sat NDT for inspector .
Action required: 17 - Rectify deficiencies prior to departure
Resolved 5 August 2011
Fire Fighting › Firemans Outfit › Quantity
Issued 13 July 2011 Resolved
Fireman's outfits are too small for many crewmembers. Provide larger fire suit.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 3 August 2011
Fire Fighting › Firemans Outfit › Quantity
Issued 13 July 2011 Resolved
Store at least two fire suits in seperate locations as per OLD I 46 CFR 96.35-15
Due 13 August 2011
Resolved 3 August 2011
Lifesaving › Lifebuoys › Markings (ship name/port)
Issued 13 July 2011 Resolved
Remove paint overspary from various liferings and remark properly.
Due 13 August 2011
Resolved 3 August 2011
Lifesaving › Rescue Boat › Markings
Issued 13 July 2011 Resolved
Remark rescue boat with vessel name and port.
Due 13 August 2011
Resolved 3 August 2011
Documentation › Safety/Response Plans/Programs › Fire Control Plans
Issued 13 July 2011 Resolved
Mark new fire suit locations on fire control plan.
Due 13 August 2011
Resolved 3 August 2011
Communications › Internal Communications System › Sound-powered Telephone
Issued 13 July 2011 Resolved
Renew blue light lense for E/R sound powered phone.
Due 13 August 2011
Resolved 3 August 2011
Construction/Loadline › Hull › Weld
Issued 11 July 2011 Resolved
C/R stbd quarter bulwarks and reweld to main deck as original.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 5 August 2011
Documentation › Markings/Placards › Lifejacket Placard
Issued 11 July 2011 Resolved
Place proper lifejacket donning placard on vessel.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 3 August 2011
Documentation › Logs/Records › Oil Record Book
Issued 11 July 2011 Resolved
Vessel is not required to carry Part 1 and Part 2 Oil record books as indicated by Class at ISM audit. Part 2 is for tankers and vsls carrying liquid cargo under Annex I. Vessel is not permitted to do this under current cargo authorization. Vessel is permitted, as an OSV, to carry excess fuel oil in unlimited quantity as listed in subchapter L. 835 is under appeal.
Action required: 705 - Other - as specified
Resolved 25 January 2013
Resolution: Deficiency cancelled by OCMI
Engineering › Sea-water System (primary cooling) › Piping
Issued 9 October 2007 Resolved
Crop and renew raw water suction and discharge piping on all four propulsion generators.
Action required: 17 - Rectify deficiencies prior to departure
Due 22 October 2007
Resolved 22 October 2007
Resolution: Received documention from Master and ABS Surveyor that all R/W suction and discharge piping was renewed and tested satisfactory.
Construction/Loadline › Hull › Longitudinal Frame
Issued 9 October 2007 Resolved
Provide proof that all wasted stiffeners and floor frames located in the forepeak are properly repaired.
Action required: 17 - Rectify deficiencies prior to departure
Due 22 October 2007
Resolved 22 October 2007
Resolution: Received documentation from Master and ABS Surveyor that all were completed and tested satisfactory.
Documentation › Safety/Response Plans/Programs › SOPEP
Issued 4 August 2005 Resolved
Update SOPEP with vessels name and contacts.
Action required: 17 - Rectify deficiencies prior to departure
Due 11 August 2005
Resolved 8 August 2005
Navigation › Piloting/Steering › Compass Deviation Table
Issued 4 August 2005 Resolved
Provide on board vessel correct compass deviation table.
Action required: 705 - Other - as specified
Due 15 August 2005
Resolved 1 June 2006
Lifesaving › Rescue Boat › Markings
Issued 4 August 2005 Resolved
Mark passenger capacity on rescue boat.
Action required: 705 - Other - as specified
Due 4 September 2005
Resolved 1 June 2006
Lifesaving › Inflatable Liferafts › Hydrostatic Release Unit
Issued 4 August 2005 Resolved
Provide documentation for port life raft hydrostatic release installation date or renew hydrostatic release.
Action required: 17 - Rectify deficiencies prior to departure
Due 15 August 2005
Resolved 4 August 2005
Lifesaving › Rescue Boat Equipment › Batteries (electric torch spares)
Issued 4 August 2005 Resolved
Renew battery in rescue boat and demonstrate proper operation of signaling lamp
Action required: 17 - Rectify deficiencies prior to departure
Due 15 August 2005
Resolved 4 August 2005
Engineering › Shafting/Propeller Arrangements › Propeller Shaft
Issued 4 August 2005 Resolved
Tighten main diesel engine port shaft packing
Action required: 17 - Rectify deficiencies prior to departure
Due 15 August 2005
Resolved 4 August 2005
Fire Fighting › Fixed CO2 Fire Extinguishing System › Operating Instructions
Issued 4 August 2005 Resolved
Post operating instructions for CO2 system ventilation closures in engine room.
Action required: 705 - Other - as specified
Due 4 September 2005
Resolved 1 June 2006
Fire Fighting › Remote Fuel Shutoff › General
Issued 4 August 2005 Resolved
Mark all emergency fuel shut off valves with purpose of valve and direction of operation.
Action required: 705 - Other - as specified
Due 15 August 2005
Resolved 4 August 2005
Pollution Prevention/Response › Prevention Equipment
Issued 27 March 2003 Resolved
Prove proper operation of the OWS to a CG marine inspector. LEGACY COMPONENT DESC: Oily Water Separator (15 ppm)
Action required: 705 - Other - as specified
Due 27 April 2003
Resolved 7 May 2003
Resolution: Attended vessel and witnessed proper operation of oily water seperator. Retained IOPP due to document being expired since May 05, 2002. IOPP not signed since 27 March 2001.
Documentation › Certificates/Documents
Issued 27 March 2003 No resolution recorded
Make vsl available for an IOPP survey conducted by a USCG marine inspector, including proper operation of the OWS. All oily wastes shall be retained on board or discharged to a reception facility with receipt provided. LEGACY COMPONENT DESC: IOPP Certificate
Action required: 705 - Other - as specified
Due 27 April 2003 — due date passed with no resolution recorded
Resolution: Witnessed operational OWS. Reatined IOPP certificate due to being expired sine May 05, 2002.
Construction/Loadline › Structures
Issued 10 February 2003 Resolved
Secure pipe to bracket (sounding tube) in #3P ballast along aft bulkhead.
Action required: 705 - Other - as specified
Resolved 27 March 2003
Construction/Loadline › Structures
Issued 10 February 2003 Resolved
Provide information on cut pipes and missing pipe sections in #3P and #2S p-tank voids.
Action required: 705 - Other - as specified
Resolved 10 February 2003
Resolution: Pipes are no longer used.
Construction/Loadline › Structures
Issued 10 February 2003 Resolved
Crop and renew port inboard p-tank support, wasted. (bottom, as marked)
Action required: 705 - Other - as specified
Resolved 27 March 2003
Construction/Loadline › Structures
Issued 10 February 2003 Resolved
Gauge stbd flange stiffener (2' x 3') along aft bulkhead (#3).
Action required: 705 - Other - as specified
Resolved 27 March 2003
Construction/Loadline › Structures
Issued 10 February 2003 Resolved
In port cofferdam, replace pad weld with insert forward of hatch/space entry way.
Action required: 705 - Other - as specified
Resolved 27 March 2003
Construction/Loadline › Structures
Issued 10 February 2003 Resolved
In port cofferdam, replace 6' section of overhead stiffener.
Action required: 705 - Other - as specified
Resolved 27 March 2003
Construction/Loadline › Structures
Issued 10 February 2003 Resolved
Gauge outboard bulkhead stiffener. Space full of debris.
Action required: 705 - Other - as specified
Resolved 27 March 2003
Construction/Loadline › Structures
Issued 10 February 2003 Resolved
In #5 stbd ballast, replace 2 sideshell stiffeners. One in first bay, 1 in second.
Action required: 705 - Other - as specified
Resolved 27 March 2003
Construction/Loadline › Structures
Issued 10 February 2003 Resolved
In stbd wraparound, replace wasted aft section of swash bulkhead in 7th bay.
Action required: 705 - Other - as specified
Resolved 27 March 2003
Construction/Loadline › Structures
Issued 10 February 2003 Resolved
In stbd wraparound, repair knifeedge on swash bulkhead in 6th bay and remove or secure old 6" piping in 9th bay.
Action required: 705 - Other - as specified
Resolved 27 March 2003
Construction/Loadline › Structures
Issued 10 February 2003 Resolved
Guage aft/stern bulkhead in 9th bay as marked (2-3 shots only).
Action required: 705 - Other - as specified
Resolved 27 March 2003
Construction/Loadline › Structures
Issued 10 February 2003 Resolved
In sub-deck plate walkway to engine room, affix junction box for bilge alarm to bulkhead and make permanent reapirs in way of fiberglass pipe patch.
Action required: 705 - Other - as specified
Resolved 27 March 2003
Construction/Loadline › Structures
Issued 10 February 2003 Resolved
Make chain lockers, sewage tank, potable water, and p-tanks available for inspection.
Action required: 705 - Other - as specified
Resolved 27 March 2003
Construction/Loadline › Structures
Issued 10 February 2003 Resolved
Flume tank modifications on-going...
Action required: 705 - Other - as specified
Resolved 27 March 2003
Construction/Loadline › Structures
Issued 10 February 2003 Resolved
Provide ABS reports on all other tanks.
Action required: 705 - Other - as specified
Resolved 27 March 2003
Documentation › Certificates/Documents
Issued 1 July 2002 Resolved
3rd party Certs do no reflect SCBA cylinder testing.
Action required: 705 - Other - as specified
Due 1 August 2002
Resolved 1 July 2002
Documentation › Manuals/Policy Documentation › Vessel Action Plan (SIP)
Issued 1 July 2002 Resolved
VAP does not address urgent and routine deficiencies.
Action required: 705 - Other - as specified
Due 1 August 2002
Resolved 1 July 2002
Engineering › Fuel Oil Service System › Filter
Issued 1 July 2002 Resolved
Install remote stop for fuel oil purifier.
Action required: 705 - Other - as specified
Due 1 August 2002
Resolved 1 July 2002
Electrical › Lighting (emergency) › Lighting Fixture
Issued 1 July 2002 Resolved
Change batteries on 01 level emergency escape light.
Action required: 705 - Other - as specified
Due 1 August 2002
Resolved 1 July 2002
Engineering
Issued 3 May 1996 Resolved
RELOCATE FUEL OIL EMERGENCY REACH RODS TO THE MAIN DECK AREA TO PROVIDE ACCESS. THE TUGGER DRUMS SHALL REMAIN EMPTY UNTIL THIS REQUIRMENT IS MET.
Condition: Unknown
Due 3 May 1996
Resolved 3 May 1996
Engineering
Issued 3 May 1996 Resolved
MAKE PERMANENT REPAIRS TO REDUCE LUBE OIL RETURN LINE HOSES TO EACH MAIN ENGINE TO LESS THEN 30 INCHES.
Condition: Unknown
Due 3 May 1996
Resolved 3 May 1996
Engineering
Issued 3 May 1996 Resolved
REMOVE ALL BRASS PLUGS FROM FUEL OIL FILTERS.
Condition: Unknown
Due 3 May 1996
Resolved 3 May 1996
Engineering
Issued 3 May 1996 Resolved
REMOVE PETCOCKS FROM FUEL OIL TRANSFER PUMP PRIMING LINE. IF REPLACED USE STEEL VALVE WITH STEEL PLUGS.
Condition: Unknown
Due 3 May 1996
Resolved 3 May 1996
Construction/Loadline
Issued 3 May 1996 Resolved
OPEN AND HOLD MAINTANCE AS NECESSARY ON ALL DECK BALL CHECK VALVES.
Condition: Unknown
Due 3 May 1996
Resolved 3 May 1996
Engineering
Issued 27 April 1995 Resolved
TEST ALARMS AND SENSORS FOR AUTOMATED ALARM SYSTEM AND SEND RESULTS TO MSD HOUMA.
Condition: Unknown
Due 27 April 1995
Resolved 27 April 1995
Documentation
Issued 27 April 1995 Resolved
PROVIDE MSD HOUMA WITH VALID FORM A SUPPLEMENT TO IOPP CERTIFICATE.
Condition: Unknown
Due 27 April 1995
Resolved 27 April 1995
Documentation
Issued 27 February 1992 Resolved
PROVIDE FCC ISSURED CARGO SHIP SAFETY RADIO TELEPHONE CERTIFICATE. VESSEL IS PROHIBTED FROM MAKING AN INTERNATIONAL VOYAGE UNTIL PROVIDED
Condition: Unknown
Due 27 February 1992
Resolved 27 February 1992
Deck/Cargo
Issued 29 March 1991 Resolved
CONDUCT OPERATIONAL TEST OF #2 LIQUID MUD PUMP, AND REMOTE STOP.
Condition: Unknown
Due 29 March 1991
Resolved 29 March 1991
Electrical
Issued 29 March 1991 Resolved
MOUNT AN EMERGENCY LIGHT ON PORTSIDE RUDDER COMPARTMENT.
Condition: Unknown
Due 29 March 1991
Resolved 29 March 1991
Engineering
Issued 29 March 1991 Resolved
REMOVE OIL FROM ENGINE ROOM BILGES.
Condition: Unknown
Due 29 March 1991
Resolved 29 March 1991
Engineering
Issued 29 March 1991 Resolved
CONDUCT OPERATIONAL TEST OF OILY WATER SEPERATOR AND 15PPM CONTENT_x001C_ MONITOR.
Condition: Unknown
Due 29 March 1991
Resolved 29 March 1991
Fire Fighting
Issued 10 May 1990 Resolved
PROVIDE POSITIVE MEANS OF CLOSING GUISE DECK VENT ON PAINT LOCKER.
Condition: Unknown
Due 10 May 1990
Resolved 10 May 1990
Construction/Loadline
Issued 10 May 1990 Resolved
PROVIDE BALL CHECK VALVES FOR FLUME TANK VENTS PORT AND STBD.
Condition: Unknown
Due 10 May 1990
Resolved 10 May 1990
Deck/Cargo
Issued 10 May 1990 Resolved
MAKE NECESSARY REPAIRS TO HYDRAULIC PIPING SYSTEM FOR ANCHOR HANDLINE WINCHS OR REPLACE SYSTEM. REPAIRS TO BE COMPLETED NO LATER THAN NEXT DRYDOCK.
Condition: Unknown
Due 10 May 1990
Resolved 10 May 1990
Documentation
Issued 10 May 1990 Resolved
PROVIDE SAFETY RADIO TELEPHONE CERTIFICATE.
Condition: Unknown
Due 10 May 1990
Resolved 10 May 1990
Engineering
Issued 28 April 1988 Resolved
REPAIR AND PROVE OPERATION OF ENGINE ROOM REMOTE CONTROLLED POWER VENT SHUT DOWN.
Condition: Unknown
Due 28 April 1988
Resolved 28 April 1988
Electrical
Issued 3 May 1985 Resolved
REPAIR GENERAL ALARM BELL IN BOW THRUSTER SPACE.
Condition: Unknown
Due 3 May 1985
Resolved 3 May 1985
Fire Fighting
Issued 3 May 1985 Resolved
REVISE FIRE AND SAFETY PLAM TO SHOW GENERAL ALARM AND ACCOMADATION FIRE ALARM SYSTEMS.
Condition: Unknown
Due 3 May 1985
Resolved 3 May 1985
Electrical
Issued 3 May 1985 Resolved
REPAIR MAIN POWER CIRCUIT BREAKER #3 AND TEST REVERSE POWER RELAYS IN PRESENCE OF C.G. INSPECTOR.
Condition: Unknown
Due 3 May 1985
Resolved 3 May 1985
Electrical
Issued 3 May 1985 Resolved
REPAIR MOTOR CONTROLLOR FOR #2 LIQUID MUD PUMP. TEST EMERGENCY STOPS IN PRESENCE OF C.G. MARINE INSPECTOR. PROPERLY LABEL REMOTE SHUTDOWNS.
Condition: Unknown
Due 3 May 1985
Resolved 3 May 1985

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.