THE STAR

THE STAR is a 1982 passenger vessel (inspected). The Coast Guard has recorded 93 inspections since 1983, most recently in April 2026, along with 155 deficiencies, 1 operational control and 1 casualty investigation in 2006.

Records from 1983 to 2026. Most recent: inspection, 3 April 2026.

Built
1982
Last inspected
3 April 2026
Documentation
Valid · documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

WDD6677
Flag
UNITED STATES
367176080
Maury page id
psix-54906

Inspections, by type

…with no type recorded20
Years with a record 40 calendar years (1983–2026)
The 93 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 1977.

Documentation record

Registered dimensions (L × B × D)81.2 ft × 26.0 ft × 3.7 ft
Registered tonnagegross 86 / net 70
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderLACROSSE RIVERBOAT CO · LA CROSSE, WI, UNITED STATES · built 1982
Hull materialSteel
PropulsionDiesel
Hull shapeNot recorded
Hull configurationNot recorded
Hailing portKNOXVILLE, TN
Trade endorsementsCoastwise, unrestricted
DocumentationValid · issued 18 March 2026 · expires 30 April 2027
Service, as the file records itPassenger (Inspected)
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it86 - Regulatory (Subpart C or D), Gross Ton
70 - Regulatory (Subpart C or D), Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 September 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.

Radio station licence

WDD6677MMSI 367176080 · active · compulsorily equipped · granted 18 February 2017, expires 28 March 2027
WCJ3894MMSI not assigned · expired · compulsorily equipped · granted 5 July 1994, cancelled 26 September 2004
FCC Universal Licensing System ship-station file of 6 September 2026, matched to this hull on its US Official Number. Status and dates are the file’s own. The licensee is not read from the file and is not shown. A lapsed licence’s MMSI is still the number the vessel transmitted under while it was valid.

Inspection history · 93

3 April 2026 Annual Inspection
Physical examination · Marine Safety Detachment Nashville · USCG Heartland District (CGD-H) · Activity 8343369
27 March 2025 Internal Structural Exam · Drydock Exam · COI Inspection
Physical examination · Marine Safety Detachment Nashville · USCG Heartland District (CGD-H) · Activity 8098742
19 March 2024 Annual Inspection
Physical examination · Marine Safety Detachment Nashville · USCG Heartland District (CGD-H) · Activity 7882199
14 September 2023 In-Service Inspection
Physical examination · Marine Safety Detachment Nashville · USCG Heartland District (CGD-H) · Activity 7793524
5 June 2023 Administrative Inspection
Administrative · Marine Safety Detachment Nashville · USCG Heartland District (CGD-H) · Activity 7703398
17 May 2023 In-Service Inspection
Physical examination · Marine Safety Detachment Nashville · USCG Heartland District (CGD-H) · Activity 7692007
23 March 2023 Annual Inspection
Physical examination · Marine Safety Detachment Nashville · USCG Heartland District (CGD-H) · Activity 7656098
28 March 2022 Annual Inspection
Physical examination · Marine Safety Detachment Nashville · USCG Heartland District (CGD-H) · Activity 7421253
22 March 2021 Annual Inspection · DAPI Audit · MTSA Verification
Physical examination · Marine Safety Detachment Nashville · USCG Heartland District (CGD-H) · Activity 7162055
28 February 2020 Internal Structural Exam · DAPI Audit · MTSA Verification · Drydock Exam · COI Inspection
Physical examination · Marine Safety Detachment Nashville · USCG Heartland District (CGD-H) · Activity 6917655
19 March 2019 Annual Inspection · MTSA Verification · DAPI Audit · Administrative Inspection
Physical examination · Marine Safety Detachment Nashville · USCG Heartland District (CGD-H) · Activity 6662616
20 March 2018 MTSA Verification · DAPI Audit · Annual Inspection
Physical examination · Marine Safety Detachment Nashville · USCG Heartland District (CGD-H) · Activity 6376422
15 March 2017 MTSA Verification · Deficiency Check · Annual Inspection
Physical examination · Marine Safety Detachment Nashville · USCG Heartland District (CGD-H) · Activity 6105773
16 March 2016 Administrative Inspection · Annual Inspection · DAPI Audit · MTSA Verification
Physical examination · Marine Safety Detachment Nashville · USCG Heartland District (CGD-H) · Activity 5875433
26 March 2014 Periodic Inspection · DAPI Audit · MTSA Verification
Physical examination · Marine Safety Detachment Nashville · USCG Heartland District (CGD-H) · Activity 4828023
22 February 2010 Internal Structural Exam · Hull Examination · Drydock Exam · MTSA Verification · COI Inspection · Administrative Inspection · DAPI Audit
Physical examination · Marine Safety Detachment Nashville · USCG Heartland District (CGD-H) · Activity 3683978
3 March 2009 Administrative Inspection · MTSA Verification · Annual Inspection
Physical examination · Marine Safety Detachment Nashville · USCG Heartland District (CGD-H) · Activity 3419944
10 March 2008 Administrative Inspection · MTSA Verification · DAPI Audit · Periodic Inspection
Physical examination · Marine Safety Detachment Nashville · USCG Heartland District (CGD-H) · Activity 3157650
6 April 2007 Deficiency Check
Physical examination · Marine Safety Detachment Nashville · USCG Heartland District (CGD-H) · Activity 2902930
16 March 2007 Annual Inspection
Physical examination · Marine Safety Detachment Nashville · USCG Heartland District (CGD-H) · Activity 2891439
13 October 2006 Deficiency Check
Physical examination · Marine Safety Detachment Nashville · USCG Heartland District (CGD-H) · Activity 2801517
5 October 2006 Damage Survey
Physical examination · Marine Safety Detachment Nashville · USCG Heartland District (CGD-H) · Activity 2794666
4 October 2006 Type not recorded
No type recorded · Marine Safety Detachment Nashville · USCG Heartland District (CGD-H) · Activity 2793938
7 March 2006 Annual Inspection · Deficiency Check
Physical examination · Marine Safety Detachment Nashville · USCG Heartland District (CGD-H) · Activity 2599152
10 March 2005 MTSA Verification · COI Inspection
Physical examination · Marine Safety Detachment Nashville · USCG Heartland District (CGD-H) · Activity 2317055
25 February 2005 Internal Structural Exam · Hull Examination
Physical examination · Marine Safety Detachment Nashville · USCG Heartland District (CGD-H) · Activity 2299060
29 November 2004 Type not recorded
No type recorded · Marine Safety Detachment Nashville · USCG Heartland District (CGD-H) · Activity 2249596
27 November 2004 Damage Survey
Physical examination · Marine Safety Detachment Nashville · USCG Heartland District (CGD-H) · Activity 2250380
10 March 2004 Re-Inspection · MTSA Verification
Physical examination · Marine Safety Detachment Nashville · USCG Heartland District (CGD-H) · Activity 2021568
2 April 2003 Annual Inspection
Physical examination · Marine Safety Detachment Nashville · USCG Heartland District (CGD-H) · Activity 1766684
26 April 2002 Deficiency Check
Physical examination · Marine Safety Detachment Nashville · USCG Heartland District (CGD-H) · Activity 1609697
20 March 2002 Annual Inspection
Physical examination · Marine Safety Detachment Nashville · USCG Heartland District (CGD-H) · Activity 1495828
18 April 2001 Re-Inspection
Physical examination · MSO Paducah · USCG Heartland District (CGD-H) · Activity 1415587
14 September 2000 Re-Inspection
Physical examination · MSO Paducah · USCG Heartland District (CGD-H) · Activity 1420390
21 June 2000 Re-Inspection
Physical examination · MSO Paducah · USCG Heartland District (CGD-H) · Activity 1430879
24 March 2000 Hull Examination · COI Inspection
Physical examination · MSO Paducah · USCG Heartland District (CGD-H) · Activity 1413678
5 August 1999 Damage Survey
Physical examination · MSO Paducah · USCG Heartland District (CGD-H) · Activity 774952
4 August 1999 Type not recorded
No type recorded · Marine Safety Detachment Nashville · USCG Heartland District (CGD-H) · Activity 57075
29 April 1999 Re-Inspection
Physical examination · MSO Paducah · USCG Heartland District (CGD-H) · Activity 1434854
27 March 1998 Re-Inspection
Physical examination · MSO Paducah · USCG Heartland District (CGD-H) · Activity 1431938
19 September 1997 Deficiency Check
Physical examination · MSO Paducah · USCG Heartland District (CGD-H) · Activity 1447755
16 September 1997 Deficiency Check
Physical examination · MSO Paducah · USCG Heartland District (CGD-H) · Activity 773455
7 March 1997 COI Inspection
Physical examination · MSO Paducah · USCG Heartland District (CGD-H) · Activity 1448876
13 November 1996 Hull Examination · Deficiency Check
Physical examination · MSO Paducah · USCG Heartland District (CGD-H) · Activity 1438521
23 May 1996 Deficiency Check
Physical examination · MSO Paducah · USCG Heartland District (CGD-H) · Activity 1084121
15 March 1996 COI Inspection
Physical examination · MSO Paducah · USCG Heartland District (CGD-H) · Activity 1428603
15 December 1995 Deficiency Check
Physical examination · MSO Paducah · USCG Heartland District (CGD-H) · Activity 883353
8 December 1995 Type not recorded
No type recorded · MSO Paducah · USCG Heartland District (CGD-H) · Activity 877573
8 December 1995 Deficiency Check
Physical examination · MSO Paducah · USCG Heartland District (CGD-H) · Activity 1185496
6 December 1995 Type not recorded
No type recorded · MSO Paducah · USCG Heartland District (CGD-H) · Activity 875616
18 November 1995 Type not recorded
No type recorded · MSO Paducah · USCG Heartland District (CGD-H) · Activity 101422
31 August 1995 Deficiency Check
Physical examination · MSO Paducah · USCG Heartland District (CGD-H) · Activity 870930
22 August 1995 Damage Survey
Physical examination · MSO Paducah · USCG Heartland District (CGD-H) · Activity 1187249
16 August 1995 Deficiency Check
Physical examination · MSO Paducah · USCG Heartland District (CGD-H) · Activity 877309
8 August 1995 Type not recorded
No type recorded · MSO Paducah · USCG Heartland District (CGD-H) · Activity 880103
28 June 1995 Deficiency Check
Physical examination · MSO Paducah · USCG Heartland District (CGD-H) · Activity 890239
23 June 1995 Type not recorded
No type recorded · MSO Paducah · USCG Heartland District (CGD-H) · Activity 39447
29 March 1995 COI Inspection
Physical examination · MSO Paducah · USCG Heartland District (CGD-H) · Activity 833066
25 July 1994 Type not recorded
No type recorded · MSO Paducah · USCG Heartland District (CGD-H) · Activity 869581
26 May 1994 Deficiency Check
Physical examination · MSO Paducah · USCG Heartland District (CGD-H) · Activity 1020354
11 April 1994 COI Inspection
Physical examination · MSO Paducah · USCG Heartland District (CGD-H) · Activity 1167639
19 May 1993 Damage Survey · Deficiency Check
Physical examination · MSO Paducah · USCG Heartland District (CGD-H) · Activity 1443377
6 May 1993 Type not recorded
No type recorded · MSO Paducah · USCG Heartland District (CGD-H) · Activity 162932
14 April 1993 COI Inspection
Physical examination · MSO Paducah · USCG Heartland District (CGD-H) · Activity 1145848
1 December 1992 Type not recorded
No type recorded · MSO Paducah · USCG Heartland District (CGD-H) · Activity 1439345
3 November 1992 Deficiency Check
Physical examination · MSO LOUISVILLE · USCG Heartland District (CGD-H) · Activity 1250790
3 September 1992 Deficiency Check
Physical examination · MSO LOUISVILLE · USCG Heartland District (CGD-H) · Activity 1256210
24 July 1992 Deficiency Check
Physical examination · MSO LOUISVILLE · USCG Heartland District (CGD-H) · Activity 951090
16 July 1992 Type not recorded
No type recorded · MSO LOUISVILLE · USCG Heartland District (CGD-H) · Activity 1267010
27 May 1992 Deficiency Check
Physical examination · MSO LOUISVILLE · USCG Heartland District (CGD-H) · Activity 1270920
23 April 1992 COI Inspection
Physical examination · MSO LOUISVILLE · USCG Heartland District (CGD-H) · Activity 951507
21 February 1992 Hull Examination
Physical examination · MSO LOUISVILLE · USCG Heartland District (CGD-H) · Activity 1266161
21 August 1991 Administrative
Administrative · MSO Paducah · USCG Heartland District (CGD-H) · Activity 1252247
23 April 1991 COI Inspection
Physical examination · MSO Paducah · USCG Heartland District (CGD-H) · Activity 1215376
23 April 1991 Administrative
Administrative · MSO Paducah · USCG Heartland District (CGD-H) · Activity 1238200
25 April 1990 COI Inspection
Physical examination · MSO Paducah · USCG Heartland District (CGD-H) · Activity 907610
26 April 1989 COI Inspection
Physical examination · MSO Paducah · USCG Heartland District (CGD-H) · Activity 1041908
20 April 1988 COI Inspection
Physical examination · MSO Paducah · USCG Heartland District (CGD-H) · Activity 1034235
20 April 1988 COI Inspection
Physical examination · MSO Paducah · USCG Heartland District (CGD-H) · Activity 1196210
24 November 1987 Hull Examination
Physical examination · MSO CHARLESTON · USCG Southeast District (CGD-SE) · Activity 1310765
22 April 1987 COI Inspection
Physical examination · MSO CHARLESTON · USCG Southeast District (CGD-SE) · Activity 1018742
21 November 1986 Type not recorded
No type recorded · MSO CHARLESTON · USCG Southeast District (CGD-SE) · Activity 1326254
1 October 1986 Type not recorded
No type recorded · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 1316079
16 September 1986 Damage Survey
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 1002094
17 July 1986 Re-Inspection
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 1294872
21 April 1986 COI Inspection
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1000911
4 March 1986 Credit Drydock
Administrative · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 988230
1 February 1986 Type not recorded
No type recorded · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1305877
3 June 1985 Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 979826
17 April 1985 Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1287221
30 August 1984 Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1280554
18 April 1984 Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1281207
14 November 1983 Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 972192

Deficiency record · 155

Engineering › Diesel Engine (auxiliary) › Injector (fuel injection)
Issued 15 March 2017 Resolved
Fuel leaks on fuel injection pump.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 15 April 2017
Resolved 20 March 2017
Resolution: Technician replaced crush rings on fuel pump and replaced fitting that was leaking.
Accommodation/Occupational Safety › Washroom/Toilet › Toilet
Issued 15 March 2017 Resolved
The elbow exiting the port sewage holding is leaking.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 15 April 2017
Resolved 20 March 2017
Resolution: leaking elbow re-sealed.
Lifesaving › Lifebuoys › Serviceable
Issued 15 March 2017 Resolved
the ring buoy on the 01 deck has faded retro and the line is brittle.
Condition: Placed in Improper Service
Action required: 701 - Prior to carriage of passengers/cargo
Due 15 April 2017
Resolved 20 March 2017
Resolution: Replaced with new life ring buoy.
Pollution Prevention/Response › Prevention Equipment › Sewage System Tank
Issued 10 March 2010 Resolved
Wastage noted on both port and starboard sewage tanks in way of weld seam along the bottom of both tanks. Make proper repairs to both tanks to the satisfaction of USCG marine inspector.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 10 April 2010
Resolved 18 May 2010
Lifesaving › Hand Flares › Expired
Issued 10 March 2010 Resolved
Handheld red flares and orange smoke flares are expired. Prior to carrying passengers, owner/operator must provide proof of new flares on board vessel.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 11 March 2010
Resolution: Owner provided proof of purchase for 8 handheld red flares (Orion). Red flares may be substituted for 3 orange smoke.
Fire Fighting › Fire Hoses › Condition
Issued 10 March 2010 Resolved
One 50 foot long fire hose on the aft upper deck had several leaks, replace fire hose prior to carrying passengers and provide proof to Coast Guard marine inspector.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 11 March 2010
Resolution: Provided proof of new fire hose in place at aft upper deck fire main.
Electrical › Electrical Distribution System (service) › Wiring
Issued 10 March 2010 Resolved
Improper wiring installation on bridge for sound system. Sound system must be plug was plugged into a power strip which was plugged into another power strip. Power strip for the sound system must be plugged directly into power outlet.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 10 April 2010
Resolved 18 May 2010
Electrical › Electrical Distribution System (service) › Wiring
Issued 10 March 2010 Resolved
Emergency Public address system wire connection was improperly installed. Permanently wire emergency public address system on bridge.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 10 April 2010
Resolved 18 May 2010
Engineering › Steering Gear System › Hydraulic Hose
Issued 10 March 2010 Resolved
Vessel's diesel engines provide hydraulic power to motors on paddle wheels. The supply and return hydraulic hoses on the port engine have small leaks. Replace supply and return hydraulic hoses to the satisfaction of Coast Guard marine inspector.
Condition: Unknown
Action required: 705 - Other - as specified
Due 10 April 2010
Resolved 18 May 2010
Fire Fighting › Fire Pumps › Pressure
Issued 10 March 2010 Resolved
Fire pump was operating at approx. 25 psi according to pressure gauge. Prove fire pump can operate at a minimum of 50 psi IAW 46 CFR 118.300
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 10 March 2010
Resolution: Provided proof of adequate pressure at pump and adequate stream at nozzle to the satisfaction of Coast Guard marine inspector.
Fire Fighting › Emergency Fire Pumps › Power Source
Issued 10 March 2010 Resolved
Emergency fire pump runs off the main engine, but bolt for engaging fire pump is missing. Repair emergency fire pump to provide adequate fire protection in case or electrical fire pump failure.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 11 March 2010
Resolution: Provided repair and satisfactory operation of emergency fire pump.
Construction/Loadline › Structures › Deck Plating
Issued 24 February 2010 Resolved
C/R metal deckplate, port aft, in way of hydraulic motor strut as marked by CG marine inspector.
Action required: 705 - Other - as specified
Due 26 March 2010
Resolved 10 March 2010
Resolution: Metal deckplate in way of aft port hydraulic motor strut has been satisfactorily replaced.
Electrical › Lighting (service) › Lighting Fixture
Issued 10 March 2008 Resolved
Fix light in stbd lifejacket space on Deck #2
Due 10 April 2008
Resolved 23 March 2008
Electrical › Lighting (service) › Lighting Fixture
Issued 10 March 2008 Resolved
Hardwire or remove Christmas lights.
Due 10 April 2008
Resolved 23 March 2008
Resolution: Lights removed
Electrical › Lighting (emergency) › Lighting Fixture
Issued 10 March 2008 Resolved
Fix emergency light in stbd aft storage room deck #2.
Due 10 April 2008
Resolved 23 March 2008
Fire Fighting › Fire Hydrants › Material
Issued 10 March 2008 Resolved
Provide spanner wrench at fire hose station Deck #2 forward.
Due 11 March 2008
Resolved 11 March 2008
Resolution: corrected
Lifesaving › Lifejacket/PFD (Type I) › Quantity
Issued 16 March 2007 Resolved
Provide 14 adult size PFD's. Vessel's passenger capacity is reduced t 311 until corrected.
Action required: 705 - Other - as specified
Due 16 April 2007
Resolved 6 April 2007
Operations/Management › Drug and Alcohol Testing › EAP Display Requirements
Issued 16 March 2007 Resolved
Post EAP information in a common location accessible t all crew members.
Action required: 705 - Other - as specified
Due 16 April 2007
Resolved 6 April 2007
Electrical › Electric Supply System (service) › Battery Installation
Issued 16 March 2007 Resolved
Provide and install cover for battery box forward of generator.
Action required: 705 - Other - as specified
Due 16 April 2007
Resolved 6 April 2007
Engineering › Fuel Oil Service System › Hose
Issued 13 October 2006 Resolved
Renew two fuel oil hoses on starboard MDE or provide proof existing hoses meet requirement found in 46CFR56.60-25(b) and SAE 1942.
Condition: Placed in Improper Service
Action required: 701 - Prior to carriage of passengers/cargo
Due 20 October 2006
Resolved 17 October 2006
Engineering › Diesel Engine (propulsion-direct drive) › Pump, High Pressure (fuel injection)
Issued 13 October 2006 Resolved
Identify and make permanent repair to fuel leak on starboard MDE, IVO fuel oil pump. Operator suspects fuel pump seal failure/leaking.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 20 October 2006
Resolved 17 October 2006
Electrical › Electric Generation Source (service) › Generator
Issued 5 October 2006 Resolved
Provide Marine Electrician's survey report.
Condition: Damaged By Earlier Event
Action required: 701 - Prior to carriage of passengers/cargo
Due 20 October 2006
Resolved 13 October 2006
Resolution: Rcvd report.
Engineering › Diesel Engine (propulsion-direct drive) › Piping (exhaust)
Issued 5 October 2006 Resolved
Renew deteriorated/damaged exhaust lagging on both main diesel engines.
Condition: Damaged By Earlier Event
Action required: 701 - Prior to carriage of passengers/cargo
Due 20 October 2006
Resolved 17 October 2006
Engineering › Fuel Oil Service System › Hose
Issued 5 October 2006 Resolved
Renew fuel hose port main diesel engine in-kind and/or IAW 46CFR56.60-25(b) (SAE-1942).
Condition: Damaged By Earlier Event
Action required: 701 - Prior to carriage of passengers/cargo
Due 20 October 2006
Resolved 13 October 2006
Resolution: Examined, verified meet SAE 1942.
Engineering › Diesel Engine (propulsion-direct drive) › Pump, High Pressure (fuel injection)
Issued 5 October 2006 Resolved
Renew/repair leaky gasket on fuel oil pump, starboard main diesel engine.
Condition: Damaged By Earlier Event
Action required: 701 - Prior to carriage of passengers/cargo
Due 20 October 2006
Resolved 13 October 2006
Resolution: Repair examined.
Accommodation/Occupational Safety › Occupational Safety › Rubbish/Waste Materials
Issued 5 October 2006 Resolved
Clean effected space (engine room) of all extinguishing agent, discharged during FF efforts.
Condition: Damaged By Earlier Event
Action required: 701 - Prior to carriage of passengers/cargo
Due 20 October 2006
Resolved 13 October 2006
Resolution: Examined space, no evidence of extinguishing agent.
Engineering › Diesel Engine (propulsion-direct drive) › Crankcase
Issued 5 October 2006 Resolved
Conduct operational test of all engineering systems effected by fire, identify/locate unknown problems damage.
Condition: Damaged By Earlier Event
Action required: 701 - Prior to carriage of passengers/cargo
Due 20 October 2006
Resolved 13 October 2006
Resolution: Operator conducted operational testing and identified fuel leak on port MDE.
Engineering › Diesel Engine (propulsion-direct drive) › Crankcase
Issued 5 October 2006 Resolved
Conduct operational test of all engineering systems in presence of CG MI.
Condition: Damaged By Earlier Event
Action required: 701 - Prior to carriage of passengers/cargo
Due 20 October 2006
Resolved 17 October 2006
Electrical › Electrical Distribution System (service) › Metallic Enclosure/Frame
Issued 7 March 2006 Resolved
Secure as designed the panel covers for the electrical distribution boxes in compartment above engine room. Item corrected prior to the completion of the inspection.
Action required: 705 - Other - as specified
Due 7 March 2006
Resolved 7 March 2006
Fire Fighting › Miscellaneous Items › Paint/Flammable Liquid Lockers
Issued 7 March 2006 Resolved
Remove combustible materials (diesel oil, lube oil, etc..) in compartment above engine room from vessel or stow in a proper flammable storage locker.
Action required: 701 - Prior to carriage of passengers/cargo
Due 7 April 2006
Resolved 16 March 2006
Engineering › Bilge Water Management System › Pump
Issued 7 March 2006 Resolved
Repair leak and prove proper operation of aux. fire/bilge pump on forward end of port main engine. Water leaking profusely from seal when pump was engaged and operationally tested.
Action required: 701 - Prior to carriage of passengers/cargo
Due 7 April 2006
Resolved 16 March 2006
Fire Fighting › Fire Hydrants › Condition
Issued 7 March 2006 Resolved
Peel back carpet to inspect pipe/deck connection for fire main riser at fire station #1 and repair as necessary. Pipe connection had pitting where indoor/outdoor carpet came in contact with riser piping.
Action required: 701 - Prior to carriage of passengers/cargo
Due 7 April 2006
Resolved 16 March 2006
Electrical › Electrical Distribution System (service) › Wiring
Issued 7 March 2006 Resolved
Remove wire nuts and replace with proper crimp connectors on wiring for hot water heater and stern light.
Action required: 705 - Other - as specified
Due 7 April 2006
Resolved 16 March 2006
Fire Fighting › Structural - A Class Divisions › Fire Doors
Issued 7 March 2006 Resolved
Repair latch and strike plate for fire door at top of stairway from main deck to second deck.
Action required: 701 - Prior to carriage of passengers/cargo
Due 7 April 2006
Resolved 16 March 2006
Fire Fighting › Fire Hoses › Condition
Issued 7 March 2006 Resolved
Vessel name not stenciled on 3 of 4 fire hoses. Discrepancy corrected prior to the completion of the inspection.
Action required: 705 - Other - as specified
Due 7 March 2006
Resolved 7 March 2006
Personnel › Manning/Qualifications › CPR Certified Personnel
Issued 10 March 2005 Resolved
Provide proof of CPR training for 50% of crew IAW NVIC 1-91.
Condition: Unknown
Due 25 April 2005
Resolved 15 April 2005
Resolution: Crew re-newed CPR Certifications.
Accommodation/Occupational Safety › Occupational Safety › Guards for Exposed Hazards
Issued 10 March 2005 Resolved
Install lagging/insulation to provide protection from exposure to exhaust piping within engineroom, IAW 46CFR116.970.
Condition: Improper/Lack of Maintenance
Due 25 April 2005
Resolved 25 April 2005
Resolution: Extended 30-days and cleared upon verified install of missing lagging. Recommended renewal of all lagging due to outer jacket breaking-down and/or missing.
Engineering › Diesel Engine (propulsion-direct drive) › Crankcase
Issued 10 March 2005 Resolved
Make permanent repair to leaking crankcase vent hose, starboard main engine, oil accumulating on the top of the block is a fire hazard.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 10 March 2005
Resolution: Leak attributed to loose hose clamp, clamp tightened and associated oil was cleaned from the top of the block, no further evidence of leak.
Engineering › Fuel Oil Storage/Transfer System › Vent Pipe
Issued 10 March 2005 Resolved
Install 30x30 flame screen, IAW 46CFR119.450(d).
Condition: Improper/Lack of Maintenance
Due 25 April 2005
Resolved 31 May 2005
Resolution: Verified fame screen installation.
Fire Fighting › Fire Pumps › Pressure
Issued 10 March 2005 Resolved
Make repairs to increase fire pump pressure from 40 psi to the required psi, IAW 46CFR118.300(b) or (46CFR181.10-1(c)).
Condition: Unknown
Due 25 April 2005
Resolved 31 May 2005
Resolution: Witnessed operational test to 50 psi.
Construction/Loadline › Hull › Hull Plating
Issued 25 February 2005 Resolved
Renew approximately 15 sq. ft. 1/4" wasted hull plate beneath gunwale starboard aft. 18" above waterline and provide gauge readings for port side gunwale, beneath walkway/catwalk.
Condition: Unknown
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 4 March 2005
Resolution: Attended vessel, verified repairs, received gauge readings for port side aft.
Deck/Cargo › Holds/Tanks › Independent Tank
Issued 25 February 2005 Resolved
Excessive wastage noted, starboard sewage tank, aft hold. Provide gauging report and repair proposal or renew in-kind.
Condition: Improper/Lack of Maintenance
Due 25 April 2005
Resolved 15 April 2005
Resolution: Wastage cropped to good steel and doubler plate installed to tank top.
Construction/Loadline › Structures › Superstructure
Issued 27 November 2004 Resolved
Starboard exhaust stack and associated support framing between exhaust stacks damaged. Repair to satisfaction of attending marine inspector prior to the carriage of passengers.
Condition: Damaged By Earlier Event
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 2 December 2004
Resolution: Repairs made. Inspection by [name withheld] per [name withheld].
Electrical › Electrical Distribution System (service) › Conductor
Issued 10 March 2004 Resolved
Provide metal hangers for loose wires above ship service generator, engineroom.
Condition: Improper/Lack of Maintenance
Due 10 April 2004
Resolved 8 April 2004
Resolution: Metal hangers installed.
Engineering › Diesel Engine (propulsion-direct drive) › Cylinder Head
Issued 10 March 2004 Resolved
Wipe excess oil from cylinder head area, identify/repair leak. If oil is coming from crankcase vent keep wiped-up. This is a potential fire hazard.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 11 March 2004
Resolution: Oil cleaned-up and identified as coming from crankcase vent/breather.
Engineering › Bilge Water Management System › Pump
Issued 10 March 2004 Resolved
Renew, wasted discharge hose on auxilary bilge/fire pump.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 12 March 2004
Resolution: Hose renewed in-kind.
Fire Fighting › Portable Dry Chemical Fire Extinguisher › Service
Issued 10 March 2004 Resolved
Provide proof of annual service for each portable fire extinguisher.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 12 March 2004
Resolution: Annual fire extinguisher service report provided.
Electrical › Electrical Distribution System (service)
Issued 10 March 2004 Resolved
Remove portable cable (extension cord) from engineroom. LEGACY COMPONENT DESC: Cable
Condition: Placed in Improper Service
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 11 March 2004
Resolution: Portable cable (extension cord) removed, and portable equipment (heater and fan) removed from service.
Navigation › Collision/Grounding Avoidance
Issued 2 April 2003 Resolved
Renew weathered/worn wiring between port/stbd running light fixtures and junction boxes on each bridge wing. LEGACY COMPONENT DESC: Navigation Lights
Condition: Improper/Lack of Maintenance
Due 2 May 2003
Resolved 1 May 2003
Resolution: Wiring renewed.
Operations/Management › Drug and Alcohol Testing
Issued 2 April 2003 Resolved
MIS not submitted for 2002. LEGACY COMPONENT DESC: MIS Submission
Condition: Unknown
Due 2 May 2003
Resolved 1 May 2003
Resolution: Sent to local CG unit, forwarded.
Personnel › Training
Issued 2 April 2003 Resolved
50% of crew need re-certification, IAW NVIC 1-91 LEGACY COMPONENT DESC: First Aid/CPR
Condition: Unknown
Due 2 May 2003
Resolved 1 May 2003
Resolution: Training scheduled, verified.
Lifesaving › Lifebuoys › Stowage
Issued 2 April 2003 Resolved
Lanyard missing to float light.
Condition: Improper Installation
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 2 April 2003
Resolution: 3'' lanyard properly installed.
Fire Fighting › Fire Hoses › Condition
Issued 22 March 2002 Resolved
Replace 1-1/2" X 50' fire hose on No.1 fire fighting station before vessel carries passengers.
Condition: Unknown
Action required: 701 - Prior to carriage of passengers/cargo
Due 22 March 2002
Resolved 22 March 2002
Engineering › Bilge Water Management System
Issued 22 March 2002 Resolved
Prove proper operation of the secondary bilge/fire fighting pump. LEGACY COMPONENT DESC: Pump
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 20 April 2002
Resolved 25 April 2002
Lifesaving › Lifejacket/PFD (Type I)
Issued 22 March 2002 Resolved
Provide separate storage, labeled with quantity of child size PFD's. LEGACY COMPONENT DESC: Storage
Action required: 705 - Other - as specified
Due 25 April 2002
Resolved 22 March 2002
Construction/Loadline
Issued 24 March 2000 Resolved
Crop out and replace a 16"X 16" section of side plate and a 16" X 16" section of bottom plate, port side at the turn of the bilge in the area of the fresh water tank space (#3 hold).
Condition: Unknown
Due 28 March 2000
Resolved 28 March 2000
Fire Fighting
Issued 24 March 2000 Resolved
Prove proper operation of all smoke detectors.
Condition: Unknown
Due 24 March 2000
Resolved 24 March 2000
Navigation
Issued 24 March 2000 Resolved
Repair both port and starboard running lights, demonstrate proper operationand secure running light fixtures to backgrounds.
Condition: Unknown
Due 24 March 2000
Resolved 28 March 2000
Construction/Loadline
Issued 24 March 2000 Resolved
Crop out and replace a 28" X 28" section of side plate, and a 28" X 28" section of bottom, port side, in the area of aft bulkhead, sewage tank space.
Condition: Unknown
Due 28 March 2000
Resolved 28 March 2000
Construction/Loadline
Issued 24 March 2000 Resolved
Crop out and replace a 16" X 16" section of bottom plate, centerline in thearea of the freshwater tank space (#3 hold).
Condition: Unknown
Due 28 March 2000
Resolved 28 March 2000
Electrical
Issued 24 March 2000 Resolved
Repair all voids installed lighting system so lighting functions.
Condition: Unknown
Due 24 March 2000
Resolved 28 March 2000
Lifesaving
Issued 24 March 2000 Resolved
Replace both life buoys on the bridge and outfit IAW 46 CFR 187.
Condition: Unknown
Due 24 March 2000
Resolved 24 March 2000
Fire Fighting
Issued 24 March 2000 Resolved
Prove proper operation of vessel fire pump at 60 PSI.
Condition: Unknown
Due 24 March 2000
Resolved 28 March 2000
Electrical
Issued 24 March 2000 Resolved
Replace sewage pump wire run with electrical wire approved for marine use and run wire through stuffing boxes.
Condition: Unknown
Due 24 March 2000
Resolved 24 March 2000
Construction/Loadline
Issued 24 March 2000 Resolved
Prove proper operation of vessel bilge pump from every strainor location, and bracket all bilge strainors and piping so they do not rest on the bottom plate.
Condition: Unknown
Due 24 March 2000
Resolved 28 March 2000
Construction/Loadline
Issued 24 March 2000 Resolved
Repair all "through bulkhead" packing glands so they are in use as_x001C_ intended.
Condition: Unknown
Due 24 March 2000
Resolved 28 March 2000
Navigation
Issued 29 April 1999 Resolved
Prove proper operation of starboard running light.
Condition: Unknown
Due 29 April 1999
Resolved 30 April 1999
Lifesaving
Issued 29 April 1999 Resolved
Properly outfit vessel lifebuoy according to 46 CFR 117.70.
Condition: Unknown
Due 29 April 1999
Resolved 30 April 1999
Fire Fighting
Issued 29 April 1999 Resolved
Inspect fire pump and locate cause for low fire fighting water pressure andcorrect, demonstrate proper fire fighting water pressure.
Condition: Unknown
Due 29 April 1999
Resolved 30 April 1999
Fire Fighting
Issued 29 April 1999 Resolved
Replace fire extinguishers that have not been inspected or have existing fire extinguishers properly inspected and tagged.
Condition: Unknown
Due 29 April 1999
Resolved 30 April 1999
Lifesaving
Issued 29 April 1999 Resolved
Post signs on ladder to upper deck with maximum passenger capacity according to stability letter.
Condition: Unknown
Due 29 April 1999
Resolved 30 April 1999
Engineering
Issued 16 September 1997 Resolved
COMPLETE REPAIRS TO PORT HYDRAULIC PROPULSION UNIT AND PROVE PROPER OPERATION TO ATTENDING INSPECTOR. ADDITIONALLY, A MANNED, STANDBY ASSIST VESSEL OF ADEQUATE HORSEPOWER SHALL BE IMMEDIATELY AVAILABLE SHOULD ANY HAZARDOUS SITUATION ARISE WHILE CARRYING PASSENGERS FOR HIRE.
Condition: Unknown
Due 1 October 1997
Resolved 23 September 1997
Electrical
Issued 15 March 1996 Resolved
PROPERLY INSTALL PERMANENT ELECTRICAL CONNECTORS IN PLACE OF "WESTERN- UNION" SPLICES THROUGHOUT VESSEL.
Condition: Unknown
Due 15 March 1996
Resolved 15 March 1996
Fire Fighting
Issued 15 March 1996 Resolved
PERMANENTLY INSTALL APPROPRIATE WRENCH AT EACH FIRE MAIN HOSE STATION.
Condition: Unknown
Due 15 March 1996
Resolved 15 March 1996
Electrical
Issued 15 March 1996 Resolved
REMOVE ALL EXCESS WIRING FROM ENGINE ROOM._x001C_ _x001C_ _x001C_ _x001C_
Condition: Unknown
Due 15 March 1996
Resolved 15 March 1996
Documentation
Issued 15 March 1996 Resolved
PROVIDE EVIDENCE OF COMPLETION OF MANDATORY DRUG AWARENESS AND SUPERVISORY TRAINING.
Condition: Unknown
Due 15 March 1996
Resolved 15 March 1996
Electrical
Issued 15 March 1996 Resolved
PROVIDE AN ELECTRICAL DIAGRAM, WITH LOAD CALCULATIONS, FOR ALL INSTALLED ENGINE ROOM EQUIPMENT.
Condition: Unknown
Due 15 March 1996
Resolved 15 March 1996
Engineering
Issued 15 March 1996 Resolved
PROPERLY INSTALL PROTECTIVE GUARDS ON DRIVE BELTS TO MAIN DIESEL ENGINES AND ASSOCIATED PUMPS._x001C_ _x001C_ _x001C_
Condition: Unknown
Due 15 March 1996
Resolved 15 March 1996
Engineering
Issued 8 December 1995 Resolved
STBD MAIN ENGINE HAS A LEAKING HEAD GASKET CAUSING ENGINE OVERHEATING. VESSEL IS TO OPERATE WITHIN A TWO MILE RADIUS OF THE STAR LANDING BERTH, KEEP STBD MAIN ENGINE IN A OPERATIONAL CONDITION WHILE UNDERWAY FOR EMERGENCY USE OR HAVE A ASSIST TUG STANDING BY FOR EMERGENCY SCENARIOS.
Condition: Unknown
Due 8 December 1995
Resolved 8 December 1995
Engineering
Issued 6 December 1995 Resolved
STBD MAIN ENGINE HAS BAD HEAD GASKET CAUSING OVERHEATING. _x001C_ VESSEL IS TO OPERATE WITHIN A TWO (2) MILE RADIUS OF THE STAR LANDING BERTHAND KEEP STBD ENGINE IN A OPERATIONAL CONDITION WHILE UNDERWAY FOR EMERGENCY USE.
Condition: Unknown
Due 6 December 1995
Resolved 6 December 1995
Engineering
Issued 22 August 1995 Resolved
MAKE PERMANENT REPAIRS TO PORT PADDLE WHEEL. VESSEL IS RESTRICTED TO OPERATING WITHIN A TWO MILE RADIUS FROM STAR LANDING BERTH WITH A TUG/TOW VESSEL STANDING BY TO PROVIDE IMMEDIATE ASSISTANCE._x001C_ _x001C_
Condition: Unknown
Due 31 August 1995
Resolved 31 August 1995
Navigation
Issued 8 August 1995 Resolved
STBD. PADDLE WHEEL GEAR BOX STRIPPED. UNTIL REPAIRS ARE COMPLETED, VESSEL IS TO OPERATE WITHIN A TWO(2) MILE RADIUS OF THE STAR LANDING BERTH AND AN ASSIST TUG WILL BE STANDING BY FOR EMERGENCY SCENARIOS.
Condition: Unknown
Due 8 August 1995
Resolved 8 August 1995
Electrical
Issued 29 March 1995 Resolved
IDENTIFY, AND CORRECT, SOURCE OF OIL ON PILOT HOUSE CONTROL CABLES.
Condition: Unknown
Due 29 March 1995
Resolved 29 March 1995
Lifesaving
Issued 29 March 1995 Resolved
PERMANENTLY ATTACH ENGINE ROOM INSULATION ABOVE SHIPS SERVICE GENERATOR.
Condition: Unknown
Due 29 March 1995
Resolved 29 March 1995
Accommodation/Occupational Safety
Issued 29 March 1995 Resolved
REMOVE TRASH FROM VOID SPACE BELOW BAR.
Condition: Unknown
Due 29 March 1995
Resolved 29 March 1995
Accommodation/Occupational Safety
Issued 29 March 1995 Resolved
REMOVE TRASH FROM DRY STORAGE VOID SPACE, AFT OF ENGINE ROOM.
Condition: Unknown
Due 29 March 1995
Resolved 29 March 1995
Electrical
Issued 29 March 1995 Resolved
REPAIR JUNCTION BOX, AND INSTALL PROTECTIVE GLOBE, ON LIGHT FIXTURE IN SPACE BELOW PILOT HOUSE.
Condition: Unknown
Due 29 March 1995
Resolved 29 March 1995
Electrical
Issued 29 March 1995 Resolved
INSTALL METALLIC HOLDBACKS ON EXPOSED OVERHEAD CABLE RUNS, SECOND DECK.
Condition: Unknown
Due 29 March 1995
Resolved 29 March 1995
Electrical
Issued 29 March 1995 Resolved
MAKE OPERABLE, OR REMOVE, 12V LIGHTING SYSTEM.
Condition: Unknown
Due 29 March 1995
Resolved 29 March 1995
Navigation
Issued 29 March 1995 Resolved
MAKE OPERABLE, OR REMOVE, BOW THRUSTER.
Condition: Unknown
Due 29 March 1995
Resolved 29 March 1995
Electrical
Issued 29 March 1995 Resolved
INSTALL PROTECTIVE GLOBES ON FORWARD, MAIN DECK, LIGHTING FIXTURES.
Condition: Unknown
Due 29 March 1995
Resolved 29 March 1995
Electrical
Issued 29 March 1995 Resolved
REPLACE MISSING PROTECTIVE GLOBE ON LIGHT FIXTURE ABOVE PILOT HOUSE, STARBOARD SIDE.
Condition: Unknown
Due 29 March 1995
Resolved 29 March 1995
Electrical
Issued 29 March 1995 Resolved
PERMANENTLY MOUNT ENGINE ROOM VENTILATION BLOWER.
Condition: Unknown
Due 29 March 1995
Resolved 29 March 1995
Lifesaving
Issued 11 April 1994 Resolved
CONDUCT FIRE, MAN OVERBOARD, FLOODING, AND ABANDON SHIP CREW DRILLS.
Condition: Unknown
Due 11 April 1994
Resolved 11 April 1994
Documentation
Issued 11 April 1994 Resolved
PROVIDE EVIDENCE THE CERTIFICATE OF DOCUMENTATION HAS BEEN RENEWED AND PLACE THE ORIGINAL DOCUMENT ON BOARD.
Condition: Unknown
Due 11 April 1994
Resolved 11 April 1994
Documentation
Issued 11 April 1994 Resolved
RENEW THE FCC STATION LICENSE FOR THE M/V THE STAR AND REMOVE OLD STATION LICENSE FOR THE M/V ROBERT E. LEE.
Condition: Unknown
Due 11 April 1994
Resolved 11 April 1994
Electrical
Issued 11 April 1994 Resolved
REPAIR OR REMOVE THE AUTOMATIC EMERGENCY LIGHTS FORWARD MAINDECK. UNTIL REPAIRED, OR IF REMOVED, ADEQUATE PORTABLE LIGHTS MUST BE MAINTAINED ON THEVESSEL.
Condition: Unknown
Due 11 April 1994
Resolved 11 April 1994
Documentation
Issued 11 April 1994 Resolved
PLACE RADIO LOG ON BOARD.
Condition: Unknown
Due 30 May 1994
Resolved 28 April 1994
Navigation
Issued 11 April 1994 Resolved
REPLACE CHARTS ON BOARD WITH UP TO DATE CHARTS.
Condition: Unknown
Due 11 April 1994
Resolved 11 April 1994
Fire Fighting
Issued 11 April 1994 Resolved
PROVE THE MAINDECK FORWARD FIRE HOSE MEETS UL STD 19 OR FED SPEC ZZ-H-451E,OR REPLACE WITH A HOSE THAT MEETS THE ABOVE STD OR SPEC.
Condition: Unknown
Due 11 April 1994
Resolved 11 April 1994
Fire Fighting
Issued 11 April 1994 Resolved
REPLACE THE GALVANIZED PIPE NIPPLE ON THE MAINDECK FORWARD FIRE HYDRANT HOSE CONNECTION WITH A BRASS, COPPER, OR OTHER SUITABLE CORROSION RESISTANTMETAL NIPPLE IN ACCORDANCE WITH 46 CFR 181.15-10(F).
Condition: Unknown
Due 11 April 1994
Resolved 11 April 1994
Engineering
Issued 14 April 1993 Resolved
REPLACE BROKEN BOARD ON PORT PADDLE WHEEL.
Condition: Unknown
Due 14 April 1993
Resolved 14 April 1993
Construction/Loadline
Issued 14 April 1993 Resolved
REPAIR JABSCO PUMP ON PORT ENGINE AND TEST.
Condition: Unknown
Due 14 April 1993
Resolved 14 April 1993
Navigation
Issued 14 April 1993 Resolved
REPLACE WIPER BLADE FOR PILOT HOUSE WINDOW
Condition: Unknown
Due 14 April 1993
Resolved 14 April 1993
Engineering
Issued 14 April 1993 Resolved
REPLACE BROKEN BOARD ON STARBOARD PADDLE WHEEL.
Condition: Unknown
Due 14 April 1993
Resolved 14 April 1993
Navigation
Issued 14 April 1993 Resolved
REPAIR HYDRAULIC OIL LEAKS ON PORT HYDRAULIC PUMP AND ACCUMMULATOR.
Condition: Unknown
Due 14 April 1993
Resolved 14 April 1993
Lifesaving
Issued 14 April 1993 Resolved
REPLACE BELT GUARD ON AIR COMPRESSOR.
Condition: Unknown
Due 14 April 1993
Resolved 14 April 1993
Engineering
Issued 14 April 1993 Resolved
REPLACE BROKEN GREASE CUP ON PORT PADDLE BEARING.
Condition: Unknown
Due 14 April 1993
Resolved 14 April 1993
Navigation
Issued 3 September 1992 Resolved
PROVIDE APPROVED NAVIGATION LIGHTS FOR ALL REQUIRED LOCATIONS._x001C_ _x001C_ _x001C_ 46 CFR 111.75-17(d)_x001C_
Condition: Unknown
Due 3 September 1992
Resolved 3 September 1992
Deck/Cargo
Issued 24 July 1992 Resolved
Provide manufacture's specification information for the hydraulic pump usedin the bow thruster installation prior to the compliance date
Condition: Unknown
Due 24 July 1992
Resolved 24 July 1992
Deck/Cargo
Issued 24 July 1992 Resolved
Provide a correction to the approved plans changing the pressure rating of the pipe from 3000psi to 2500psi as installed prior to the compliance date.
Condition: Unknown
Due 24 July 1992
Resolved 24 July 1992
Deck/Cargo
Issued 24 July 1992 Resolved
Install adequate pipe hangers according to good marine practice for the hydraulic lines in the bow thruster installation prior to the compliance date.
Condition: Unknown
Due 24 July 1992
Resolved 24 July 1992
Lifesaving
Issued 23 April 1992 Resolved
Provide 45 approved adult life preservers required by 46 CFR 180.25-5(a) not later than the compliance date. The total number of person aboard is restricted to 277 until life preservers are on board.
Condition: Unknown
Due 23 May 1992
Resolved 28 May 1992
Construction/Loadline
Issued 23 April 1992 Resolved
Provide an approved hand bilge/fire pump required by 46 CFR TABLE 182.25- 10(a) prior to carrying passengers but not later than the compliance date.
Condition: Unknown
Due 23 May 1992
Resolved 28 May 1992
Fire Fighting
Issued 23 April 1992 Resolved
Provide an approved B-I portable fire extinquisher required by 46 CFR TABLE181.30-1(a) prior to carrying passengers but not later than the compliance date.
Condition: Unknown
Due 23 May 1992
Resolved 28 May 1992
Lifesaving
Issued 23 April 1992 Resolved
Provide 6 red flare and 6 orange smoke distress signal required by 46 CFR_x001C_ 180.35-5 prior to carrying passengers but not later than the compliance date.
Condition: Unknown
Due 23 May 1992
Resolved 28 May 1992
Unknown
Issued 23 April 1992 Resolved
Provide a MARPOL V discharge of plastics or garbage prohibited placard required by 33 CFR 151.59 not later than the compliance date.
Condition: Unknown
Due 23 May 1992
Resolved 28 May 1992
Navigation
Issued 21 November 1986 Resolved
POST STABILITY LETTER UNDER GLASS IN WHEELHOUSE.
Condition: Unknown
Due 21 November 1986
Resolved 21 November 1986
Engineering
Issued 21 November 1986 Resolved
REPAIR PORT TACHOMETER, WHEELHOUSE CONSOLE.
Condition: Unknown
Due 21 November 1986
Resolved 21 November 1986
Fire Fighting
Issued 21 November 1986 Resolved
REPAIR OR REPLACE INOPERATIVE BILGE PUMP PRIOR TO CARRYING PASSENGERS.
Condition: Unknown
Due 21 November 1986
Resolved 21 November 1986
Unknown
Issued 16 September 1986 Resolved
REPLACE PORT FLANKING RUDDER BEFORE CARRYING PASSENGERS FOR HIRE.
Condition: Unknown
Due 16 September 1986
Resolved 16 September 1986
Unknown
Issued 16 September 1986 Resolved
REPAIR FLANKING RUDDER HYDRAULIC CYLINDER AT AFT STATION SO THAT CYLINDER DOES NOT LEAK HYDRAULIC FLUID UNDER NORMAL OPERATING CONDITIONS.
Condition: Unknown
Due 16 September 1986
Resolved 16 September 1986
Construction/Loadline
Issued 4 March 1986 Resolved
LABEL REMOTE FUEL OIL SHUT OFF VALVES.
Condition: Unknown
Due 4 March 1986
Resolved 4 March 1986
Electrical
Issued 4 March 1986 Resolved
SECURE BATTERY BOXES IN ENGINE ROOM.
Condition: Unknown
Due 4 March 1986
Resolved 4 March 1986
Electrical
Issued 4 March 1986 Resolved
SECURE ELECTRICAL CABLE IN AFT VOID.
Condition: Unknown
Due 4 March 1986
Resolved 4 March 1986
Lifesaving
Issued 4 March 1986 Resolved
PROPERLY LABEL CHILDRENS LIFE PRESERVER STORAGE.
Condition: Unknown
Due 4 March 1986
Resolved 4 March 1986
Accommodation/Occupational Safety
Issued 4 March 1986 Resolved
REPLACE SO CABLE TO WATER CONDITIONER IN AFT VOID WITH APPROVED TYPE.
Condition: Unknown
Due 4 March 1986
Resolved 4 March 1986
Fire Fighting
Issued 17 April 1985 Resolved
REMOVE THE FLEXIBLE HOSE COUPLING FROM THE 2 AND 1/2 INCH FIRE MAIN LINE OVER THE BELT DRIVEN PUMP ON THE PORT MAIN ENGINE AND REPLACE IT WITH THE PROPER PIPEFITTINGS OR VIBRATION ABSORBING FLEXIBLE JOINT.
Condition: Unknown
Due 17 April 1985
Resolved 17 April 1985
Accommodation/Occupational Safety
Issued 17 April 1985 Resolved
REPLACE THE MISSING INSULATION AND REINSTALL THE EXPANDED STEEL WHERE IT FALLEN ON BOTH PORT AND STARBOARD SIDE OF THE ENIGNE ROOM OVERHEAD.
Condition: Unknown
Due 17 April 1985
Resolved 17 April 1985
Fire Fighting
Issued 17 April 1985 Resolved
REROUTE APPROXIMATELY 12 FEET OF 2 AND 1/2 INCH GALVANIZED FIREMAIN PIPING WHICH IS PRESENTLY RUN OVER THE GENERATOR SWITCHBOARD OR PROVIDE WELDED JOINTS AND DRIP SHIELD AS PER 46CFR56.50(D) AND PROVIDE PROPER HANGERS AND SUPPORTS FOR THE SAME.
Condition: Unknown
Due 17 April 1985
Resolved 17 April 1985
Engineering
Issued 17 April 1985 Resolved
REPLACE THE EXISTING FLEXIBLE FUEL OIL SUPPLY AND RETURN HOSES ON BOTH MAINDIESEL ENGINES AND GENERATOR WITH APPROVED FLEXIBLE HOSE AS PER 46CFR182.20-40(II)
Condition: Unknown
Due 17 April 1985
Resolved 17 April 1985
Engineering
Issued 17 April 1985 Resolved
INSTALL FUEL OIL SHUT OFF VALVES ON THE SUPPLY HOSES TO BOTH MAIN ENGINES AND GENERATOR AT THE ENGINE END OF EACH LINE AS PER 46CFR182.20-40(3) AND PROVIDE PROPER PROTECTION AND SUPPORTS FOR THE SAMES AS PER 46CFR182.20-40 (2).
Condition: Unknown
Due 17 April 1985
Resolved 17 April 1985
Engineering
Issued 17 April 1985 Resolved
PROPERLY MOUNT PROTECTIVE GUARDS AROUND BELT DRIVES AND PULLEYS ON BOTH MAIN DIESEL ENGINES AND PROVIDE ADEQUATE PROTECTION AND SUPPORT ALL FLEXIBLE HOSE, CABLE AND WIRING IN THE VICINITY OF THE BELT DRIVES.
Condition: Unknown
Due 17 April 1985
Resolved 17 April 1985
Electrical
Issued 17 April 1985 Resolved
REPLACE THE PROTECTIVE GUARD WHICH BELONGS AROUND THE BELT DRIVES AND PULLEYS ON THE SHIP'S SERVICE GENERATOR. PROVIDE ADEQUATE PROTECTION AND SUPPORT FOR ALL FLEXIBLE HOSE, CABLE AND WIRING IN THE VICINITY OF THE BELTDRIVE.
Condition: Unknown
Due 17 April 1985
Resolved 17 April 1985
Electrical
Issued 17 April 1985 Resolved
PROPERLY ENCLOSE ALL EXPOSED WIRING AND SOLENOID SWITCHES THAT OPERATE THE FWD GANGWAY AND ARE LOCATED ON THE PORT BULKHEAD INSIDE THE ENGINE ROOM COMPANIONWAY. REPLACE THE EXISTING WIRING WITH APPROVED CABLE AND INSTALL WITH ACCEPTABLE STANDARDS. PROTECT AND SUPPORT ALL NEW AND EXISTING CABLES.
Condition: Unknown
Due 17 April 1985
Resolved 17 April 1985
Electrical
Issued 17 April 1985 Resolved
REMOVE ALL ENGINE START BATTERIES FROM THE BILGE AND PERMANENTLY MOUNT BRACKETS AND HOLDERS TO SECURE BATTERY BOXES IN PLACE. RENEW THE COVERS TO PROVIDE PROTECTION TO TERMINALS AS PER 46CFR 183.05-20. REPLACE TERMINALS AND CONNECTIONS AS REQUIRED. PROTECT AND SUPPORT ALL BATTERY CABLES.
Condition: Unknown
Due 17 April 1985
Resolved 17 April 1985
Engineering
Issued 17 April 1985 Resolved
PROVIDE PROPER SUPPORTS AND HANGERS FOR ALL ENGINE ROOM PIPING SYSTEMS INCLUDING THE FIRE MAIN, BILGE, BOTH MAIN ENGINE AND GENERATOR FRESH WATER COOLING LINES, HYDRAULIC LINES AND FUEL OIL SYSTEM LINES AND HOSES.
Condition: Unknown
Due 17 April 1985
Resolved 17 April 1985
Electrical
Issued 17 April 1985 Resolved
REMOVE ALL NON-APPROVED ELECTRICAL WIRING AND IMPROPER INSTALLATIONS IN THEMAIN ENGINE ROOM AND COMPANIONWAY. REPLACE WITH APPROVED CABLES, MATERIALSAND METHODS AS PER 46CFR183.05 AND 183.10. PROVIDE ADEQUATE PROTECTION, SUPPORT AND HANGERS AS REQUIRED.
Condition: Unknown
Due 17 April 1985
Resolved 17 April 1985
Fire Fighting
Issued 17 April 1985 Resolved
MAKE PERMANENT REPAIRS TO THE INSTALLED FIXED FIRE MAIN SYSTEM TO PROVIDE AN EFFECTIVE STREAM FROM A HOSE CONNECTED TO THE HIGHEST OUTLET AND NOT LESS THAN 50 GALLONS PER MINUTE AT 60 PSI.
Condition: Unknown
Due 17 April 1985
Resolved 17 April 1985
Construction/Loadline
Issued 17 April 1985 Resolved
MAKE PERMANENT REPAIRS TO STARBOARD MAIN ENGINE FRESHWATER COOLING LINE TO KEEL COOLER PENETRATION THROUGH THE SIDE SHELL STARBOARD SIDE MAIN ENGINE ROOM.
Condition: Unknown
Due 17 April 1985
Resolved 17 April 1985
Engineering
Issued 17 April 1985 Resolved
PROVIDE FIXED CONTAINMENT AROUND THE FILL AND VENT LINES ON THE MAIN DECK FORWARD, STARBOARD SIDE FUELING STATION.
Condition: Unknown
Due 17 April 1985
Resolved 17 April 1985
Electrical
Issued 17 April 1985 Resolved
PROPERLY REPAIR, REMOVE, OR ENCLOSE THE LOOSE PHONE LINE OUTSIDE THE LOWER DECK ON THE STARBOARD SIDE FORWARD NEXT TO THE SHORE TIE CONNECTION.
Condition: Unknown
Due 17 April 1985
Resolved 17 April 1985
Construction/Loadline
Issued 17 April 1985 Resolved
PROVIDE PROOF OF PLAN APPROVAL BY THE COAST GUARD FOR ALTERATIONS TO BOTH MAIN ENGINE MOUNTING FRAMES AND CUTOUTS OF THE TRANSVERSE FRAMES UNDER THE MAIN ENGINES.
Condition: Unknown
Due 17 April 1985
Resolved 17 April 1985
Construction/Loadline
Issued 18 April 1984 Resolved
MAKE PERMANENT REPAIRS TO SMALL HOLES ABOVE WATERLINE IN OVERHANG AREA OF HULL: I.E. ENG RM PORT SIDE, AFT OF FWD BDH, COMPARTMENT OFF OF E/R.
Condition: Unknown
Due 18 April 1984
Resolved 18 April 1984
Unknown
Issued 18 April 1984 Resolved
THE FOLLOWING DEFICIENCIES ARE FOR THE BELLE OF BEAUMONT, DN647763.
Condition: Unknown
Due 18 April 1984
Resolved 18 April 1984
Fire Fighting
Issued 18 April 1984 Resolved
PROVIDE NEW FIRE PUMP DISCHARGE PRESSURE GAUGE IN ENGINE ROOM.
Condition: Unknown
Due 18 April 1984
Resolved 18 April 1984
Engineering
Issued 18 April 1984 Resolved
PROVIDE NEW OIL PRESSURE GAUGE FOR STARBOARD ENGINE AT PILOTHOUSE.
Condition: Unknown
Due 18 April 1984
Resolved 18 April 1984
Construction/Loadline
Issued 18 April 1984 Resolved
MAKE PERMANENT REPAIRS TO AFT BHD AT PENETRATION OF HYDRAULIC LINES, ADJA- CENT TO SEWAGE TANK COMPARTMENT.
Condition: Unknown
Due 18 April 1984
Resolved 18 April 1984
Unknown
Issued 18 April 1984 Resolved
REPLACE PORTABLE CABLE FOR CARBONATING MACHINE.
Condition: Unknown
Due 18 April 1984
Resolved 18 April 1984
Unknown
Issued 18 April 1984 Resolved
INSTALL CORRECT SIZE/TYPE CABLE FROM MAIN DISTRIBUTION PANEL TO AIR COM- PRESSOR; PROVIDE A DISCONNECT SWITCH BY THE AIR COMPRESSOR.
Condition: Unknown
Due 18 April 1984
Resolved 18 April 1984
Construction/Loadline
Issued 18 April 1984 Resolved
REPLACE 30 X 30 MESH FLAME SCREEN FOR FO TANK VENT.
Condition: Unknown
Due 18 April 1984
Resolved 18 April 1984
Lifesaving
Issued 18 April 1984 Resolved
PROPERLY LABEL STOWAGE AREAS FOR CHILDREN'S LIFE PRESERVERS.
Condition: Unknown
Due 18 April 1984
Resolved 18 April 1984
Lifesaving
Issued 18 April 1984 Resolved
PROVIDE PYROTECHNIC SIGNALS IN ACCORDANCE WITH 46 CFR 180.35.
Condition: Unknown
Due 18 April 1984
Resolved 18 April 1984
Engineering
Issued 18 April 1984 Resolved
PROPERLY SECURE FW EXPANSION TANKS FOR ENGINES.
Condition: Unknown
Due 18 April 1984
Resolved 18 April 1984
Electrical
Issued 18 April 1984 Resolved
PROVIDE GLOBES FOR LIGHT FIXTURES AS NEEDED.
Condition: Unknown
Due 18 April 1984
Resolved 18 April 1984

Casualty record · 1

4 October 2006Routine · role: Involved in a Marine Casualty · activity 2793938
Each line is an incident investigation the Coast Guard recorded with this hull among the vessels involved, with the date and the classification the Coast Guard gave it, and the bridge, lock or dam the investigation names where it names one. Involvement is not fault. The investigation narrative is not published. Source: IIR, through 2026.

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.