Records from 2006 to 2026. Most recent: inspection, 22 June 2026.
Inspection history · 127
22 June 2026
Administrative Inspection
Administrative · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 8410218
18 June 2026
Administrative Inspection
Administrative · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 8407905
11 June 2026
Administrative Inspection
Administrative · Marine Safety Unit Duluth · USCG Great Lakes District (CGD-GL) · Activity 8402989
20 April 2026
Administrative Inspection
Administrative · Sector Northern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 8352483
6 February 2026
Deficiency Check
Physical examination · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 8307102
3 February 2026
Administrative Inspection · Drydock Extension · Internal Structural Exam
Physical examination · Marine Safety Unit Cleveland · USCG Great Lakes District (CGD-GL) · Activity 8305463
2 February 2026
Deficiency Check · Vessel Attendance · COI Inspection · Administrative Inspection
Physical examination · Marine Safety Unit Cleveland · USCG Great Lakes District (CGD-GL) · Activity 8309664
12 January 2026
Administrative Inspection
Administrative · Marine Safety Unit Duluth · USCG Great Lakes District (CGD-GL) · Activity 8294925
10 January 2026
Administrative Inspection
Administrative · Sector Northern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 8294163
8 January 2026
Deficiency Check · Administrative Inspection
Physical examination · Marine Safety Unit Duluth · USCG Great Lakes District (CGD-GL) · Activity 8292350
24 December 2025
Administrative Inspection
Administrative · Marine Safety Unit Duluth · USCG Great Lakes District (CGD-GL) · Activity 8287088
13 December 2025
Administrative Inspection
Administrative · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 8282834
2 December 2025
Administrative Inspection
Administrative · Sector Detroit · USCG Great Lakes District (CGD-GL) · Activity 8276145
18 November 2025
Administrative Inspection · Drydock Extension
Administrative · USCG Great Lakes District (dp) · USCG Great Lakes District (CGD-GL) · Activity 8270313
13 November 2025
Annual Survey
Physical examination · Marine Safety Unit Duluth · USCG Great Lakes District (CGD-GL) · Activity 8270634
29 October 2025
Administrative Inspection · Deficiency Check
Physical examination · Marine Safety Unit Duluth · USCG Great Lakes District (CGD-GL) · Activity 8260708
29 October 2025
Type not recorded
No type recorded · Marine Safety Unit Duluth · USCG Great Lakes District (CGD-GL) · Activity 8306571
16 September 2025
Administrative Inspection
Administrative · Marine Safety Unit Duluth · USCG Great Lakes District (CGD-GL) · Activity 8236068
11 September 2025
Administrative Inspection · Deficiency Check
Physical examination · Sector Detroit · USCG Great Lakes District (CGD-GL) · Activity 8231423
10 September 2025
Type not recorded
No type recorded · Sector Detroit · USCG Great Lakes District (CGD-GL) · Activity 8239820
21 August 2025
Damage Survey · Deficiency Check · Administrative Inspection
Physical examination · Marine Safety Unit Cleveland · USCG Great Lakes District (CGD-GL) · Activity 8214834
21 August 2025
Type not recorded
No type recorded · Marine Safety Unit Cleveland · USCG Great Lakes District (CGD-GL) · Activity 8236796
19 August 2025
Deficiency Check
Physical examination · Marine Safety Unit Duluth · USCG Great Lakes District (CGD-GL) · Activity 8213664
8 May 2025
Administrative Inspection · Annual Survey
Physical examination · Marine Safety Unit Duluth · USCG Great Lakes District (CGD-GL) · Activity 8131034
18 April 2025
Administrative Inspection
Administrative · Sector Northern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 8114158
16 April 2025
Deficiency Check · Administrative Inspection
Physical examination · Marine Safety Unit Duluth · USCG Great Lakes District (CGD-GL) · Activity 8113204
20 March 2025
Bulk Liquid Transfer Monitor
Physical examination · Marine Safety Unit Duluth · USCG Great Lakes District (CGD-GL) · Activity 8096825
21 February 2025
Administrative Inspection · Annual Inspection
Physical examination · Marine Safety Unit Duluth · USCG Great Lakes District (CGD-GL) · Activity 8084240
12 December 2024
Deficiency Check
Physical examination · Sector Detroit · USCG Great Lakes District (CGD-GL) · Activity 8046503
27 November 2024
Administrative Inspection · Annual Survey
Physical examination · Marine Safety Unit Duluth · USCG Great Lakes District (CGD-GL) · Activity 8040862
14 November 2024
Administrative Inspection
Administrative · Marine Safety Unit Toledo · USCG Great Lakes District (CGD-GL) · Activity 8035015
2 November 2024
Administrative Inspection
Administrative · Marine Safety Unit Toledo · USCG Great Lakes District (CGD-GL) · Activity 8028428
23 August 2024
Administrative Inspection
Administrative · Marine Safety Unit Duluth · USCG Great Lakes District (CGD-GL) · Activity 7987837
30 July 2024
Administrative Inspection
Administrative · Sector Lake Michigan · USCG Great Lakes District (CGD-GL) · Activity 7970948
16 July 2024
Deficiency Check · Administrative Inspection
Physical examination · Marine Safety Unit Duluth · USCG Great Lakes District (CGD-GL) · Activity 7959426
12 July 2024
Administrative Inspection
Administrative · Sector Northern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 7956647
1 July 2024
Administrative Inspection
Administrative · Marine Safety Unit Duluth · USCG Great Lakes District (CGD-GL) · Activity 7946605
29 June 2024
Administrative Inspection
Administrative · Sector Northern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 7945150
13 May 2024
Administrative Inspection
Administrative · USCG Great Lakes District (dp) · USCG Great Lakes District (CGD-GL) · Activity 7911210
7 February 2024
Liferaft Servicing
Physical examination · Marine Safety Unit Cleveland · USCG Great Lakes District (CGD-GL) · Activity 7862074
17 January 2024
Annual Inspection
Physical examination · Marine Safety Unit Cleveland · USCG Great Lakes District (CGD-GL) · Activity 7850304
1 December 2023
Administrative Inspection
Administrative · USCG Great Lakes District (dp) · USCG Great Lakes District (CGD-GL) · Activity 7832161
6 November 2023
In-Service Inspection
Physical examination · Sector Detroit · USCG Great Lakes District (CGD-GL) · Activity 7820723
8 October 2023
Administrative Inspection
Administrative · Sector Detroit · USCG Great Lakes District (CGD-GL) · Activity 7805392
18 September 2023
In-Service Inspection
Physical examination · Marine Safety Unit Duluth · USCG Great Lakes District (CGD-GL) · Activity 7793940
14 September 2023
Administrative Inspection
Administrative · Marine Safety Unit Cleveland · USCG Great Lakes District (CGD-GL) · Activity 7795880
26 August 2023
Administrative Inspection
Administrative · Sector Northern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 7777051
2 July 2023
Type not recorded
No type recorded · Sector Northern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 7733193
2 June 2023
Deficiency Check · Administrative Inspection
Physical examination · Sector Detroit · USCG Great Lakes District (CGD-GL) · Activity 7710106
28 May 2023
Damage Survey · Deficiency Check
Physical examination · Marine Safety Unit Duluth · USCG Great Lakes District (CGD-GL) · Activity 7698163
17 May 2023
Administrative Inspection
Administrative · Marine Safety Unit Duluth · USCG Great Lakes District (CGD-GL) · Activity 7690995
10 May 2023
Administrative Inspection
Administrative · Marine Safety Unit Duluth · USCG Great Lakes District (CGD-GL) · Activity 7689215
14 March 2023
Administrative Inspection
Administrative · Marine Safety Unit Duluth · USCG Great Lakes District (CGD-GL) · Activity 7658589
19 January 2023
Administrative Inspection · Examination of Repairs · Deficiency Check · MTSA Verification · Annual Inspection · In-Service Inspection
Physical examination · Marine Safety Unit Toledo · USCG Great Lakes District (CGD-GL) · Activity 7641590
29 December 2022
Deficiency Check
Physical examination · Sector Detroit · USCG Great Lakes District (CGD-GL) · Activity 7614824
26 December 2022
Administrative Inspection
Administrative · Sector Northern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 7613082
26 December 2022
Type not recorded
No type recorded · Sector Northern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 7613492
17 October 2022
In-Service Inspection
Physical examination · Marine Safety Unit Duluth · USCG Great Lakes District (CGD-GL) · Activity 7580872
26 September 2022
Deficiency Check
Physical examination · Marine Safety Unit Duluth · USCG Great Lakes District (CGD-GL) · Activity 7566252
2 September 2022
Administrative Inspection
Administrative · Sector Detroit · USCG Great Lakes District (CGD-GL) · Activity 7549400
26 August 2022
Administrative Inspection
Administrative · Sector Detroit · USCG Great Lakes District (CGD-GL) · Activity 7546505
24 August 2022
Administrative Inspection
Administrative · Marine Safety Unit Duluth · USCG Great Lakes District (CGD-GL) · Activity 7542542
10 August 2022
Administrative Inspection
Administrative · Marine Safety Unit Duluth · USCG Great Lakes District (CGD-GL) · Activity 7529942
21 July 2022
Administrative Inspection
Administrative · Sector Detroit · USCG Great Lakes District (CGD-GL) · Activity 7512837
14 June 2022
Deficiency Check · Administrative Inspection
Physical examination · Marine Safety Unit Toledo · USCG Great Lakes District (CGD-GL) · Activity 7477720
11 June 2022
Administrative Inspection
Administrative · Marine Safety Unit Duluth · USCG Great Lakes District (CGD-GL) · Activity 7474735
11 June 2022
Type not recorded
No type recorded · Marine Safety Unit Duluth · USCG Great Lakes District (CGD-GL) · Activity 7569261
12 May 2022
Administrative Inspection
Administrative · Marine Safety Unit Duluth · USCG Great Lakes District (CGD-GL) · Activity 7449274
9 May 2022
Type not recorded
No type recorded · Suspension & Revocation National Center of Expertise · Activity 7537594
5 April 2022
Administrative Inspection
Administrative · Sector Detroit · USCG Great Lakes District (CGD-GL) · Activity 7425186
20 January 2022
Examination of Repairs · Deficiency Check · Annual Survey · Annual Inspection · Internal Structural Exam · Administrative Inspection · Special
Physical examination · Marine Safety Unit Duluth · USCG Great Lakes District (CGD-GL) · Activity 7387248
23 December 2021
In-Service Inspection
Physical examination · Sector Northern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 7371760
17 December 2021
Administrative Inspection · Deficiency Check
Physical examination · Marine Safety Unit Duluth · USCG Great Lakes District (CGD-GL) · Activity 7369602
3 December 2021
Special · Administrative Inspection · Deficiency Check
Physical examination · Marine Safety Unit Duluth · USCG Great Lakes District (CGD-GL) · Activity 7363044
24 November 2021
Administrative Inspection
Administrative · Marine Safety Unit Duluth · USCG Great Lakes District (CGD-GL) · Activity 7358670
29 October 2021
Administrative Inspection
Administrative · Marine Safety Unit Cleveland · USCG Great Lakes District (CGD-GL) · Activity 7343350
4 October 2021
Administrative Inspection
Administrative · Marine Safety Unit Duluth · USCG Great Lakes District (CGD-GL) · Activity 7326248
1 August 2021
Examination of Repairs · Administrative Inspection
Physical examination · Sector Detroit · USCG Great Lakes District (CGD-GL) · Activity 7275199
1 August 2021
Type not recorded
No type recorded · Sector Detroit · USCG Great Lakes District (CGD-GL) · Activity 7276577
29 July 2021
Administrative Inspection · Deficiency Check
Physical examination · Marine Safety Unit Duluth · USCG Great Lakes District (CGD-GL) · Activity 7272613
26 May 2021
Administrative Inspection
Administrative · Marine Safety Unit Duluth · USCG Great Lakes District (CGD-GL) · Activity 7208182
13 April 2021
Deficiency Check · Administrative Inspection
Physical examination · Marine Safety Unit Duluth · USCG Great Lakes District (CGD-GL) · Activity 7174353
13 April 2021
Administrative Inspection
Administrative · Marine Safety Unit Sturgeon Bay · USCG Great Lakes District (CGD-GL) · Activity 7174390
18 January 2021
Damage Survey · Drydock Exam · MTSA Verification · Internal Structural Exam · Examination of Repairs · COI Inspection
Physical examination · Marine Safety Unit Sturgeon Bay · USCG Great Lakes District (CGD-GL) · Activity 7126198
13 November 2020
Administrative Inspection · Annual Survey
Physical examination · Marine Safety Unit Duluth · USCG Great Lakes District (CGD-GL) · Activity 7099192
15 October 2020
Deficiency Check · Damage Survey
Physical examination · Marine Safety Unit Cleveland · USCG Great Lakes District (CGD-GL) · Activity 7077589
14 October 2020
Administrative Inspection
Administrative · Sector Detroit · USCG Great Lakes District (CGD-GL) · Activity 7077039
11 August 2020
Deficiency Check · In-Service Inspection · Administrative Inspection
Physical examination · Marine Safety Unit Duluth · USCG Great Lakes District (CGD-GL) · Activity 7030800
29 July 2020
COI Inspection · MTSA Verification
Physical examination · Marine Safety Unit Toledo · USCG Great Lakes District (CGD-GL) · Activity 7007971
11 May 2020
Plan Review (Other than "T") · In-Service Inspection
Physical examination · Marine Safety Unit Toledo · USCG Great Lakes District (CGD-GL) · Activity 6953104
12 March 2020
In-Service Inspection
Physical examination · Marine Safety Unit Toledo · USCG Great Lakes District (CGD-GL) · Activity 6925505
27 January 2020
Drydock Extension
Administrative · Marine Safety Unit Toledo · USCG Great Lakes District (CGD-GL) · Activity 6897825
22 January 2020
In-Service Inspection
Physical examination · Marine Safety Unit Toledo · USCG Great Lakes District (CGD-GL) · Activity 6894096
10 January 2020
Type not recorded
No type recorded · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 6886705
23 December 2019
In-Service Inspection · Administrative Inspection
Physical examination · Marine Safety Unit Toledo · USCG Great Lakes District (CGD-GL) · Activity 6878332
1 August 2019
Deficiency Check · Administrative Inspection · Examination of Repairs
Physical examination · Marine Safety Unit Duluth · USCG Great Lakes District (CGD-GL) · Activity 6770414
7 July 2019
Administrative Inspection
Administrative · Sector Northern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 6741536
7 July 2019
Deficiency Check · Administrative Inspection
Physical examination · Marine Safety Unit Duluth · USCG Great Lakes District (CGD-GL) · Activity 6746509
21 May 2019
Type not recorded
No type recorded · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 6727305
21 March 2019
MTSA Verification · Annual Inspection
Physical examination · Marine Safety Unit Toledo · USCG Great Lakes District (CGD-GL) · Activity 6646877
8 February 2019
Examination of Repairs · Administrative Inspection
Physical examination · Marine Safety Unit Toledo · USCG Great Lakes District (CGD-GL) · Activity 6622267
22 January 2019
In-Service Inspection
Physical examination · Marine Safety Unit Toledo · USCG Great Lakes District (CGD-GL) · Activity 6613820
3 January 2019
Type not recorded
No type recorded · Sector Detroit · USCG Great Lakes District (CGD-GL) · Activity 6605126
24 December 2018
Administrative Inspection
Administrative · Sector Detroit · USCG Great Lakes District (CGD-GL) · Activity 6602355
19 December 2018
Administrative Inspection
Administrative · Marine Safety Unit Duluth · USCG Great Lakes District (CGD-GL) · Activity 6600258
2 December 2018
Deficiency Check
Physical examination · Sector Northern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 6591323
30 November 2018
Administrative Inspection
Administrative · Sector Northern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 6589881
11 November 2018
Damage Survey
Physical examination · Marine Safety Unit Cleveland · USCG Great Lakes District (CGD-GL) · Activity 6580465
11 November 2018
Type not recorded
No type recorded · Marine Safety Unit Cleveland · USCG Great Lakes District (CGD-GL) · Activity 6584185
4 October 2018
Deficiency Check · Administrative Inspection
Physical examination · Marine Safety Unit Duluth · USCG Great Lakes District (CGD-GL) · Activity 6557651
7 August 2018
Deficiency Check
Physical examination · Marine Safety Unit Toledo · USCG Great Lakes District (CGD-GL) · Activity 6510172
1 June 2018
Administrative Inspection
Administrative · Marine Safety Unit Duluth · USCG Great Lakes District (CGD-GL) · Activity 6434143
20 March 2018
Examination of Repairs · Periodic Inspection · MTSA Verification
Physical examination · Marine Safety Unit Toledo · USCG Great Lakes District (CGD-GL) · Activity 6375428
21 February 2018
Liferaft Servicing
Physical examination · Marine Safety Unit Cleveland · USCG Great Lakes District (CGD-GL) · Activity 6364689
26 January 2018
In-Service Inspection
Physical examination · Marine Safety Unit Toledo · USCG Great Lakes District (CGD-GL) · Activity 6345163
26 January 2018
Examination of Repairs · In-Service Inspection
Physical examination · Marine Safety Unit Toledo · USCG Great Lakes District (CGD-GL) · Activity 6376432
20 November 2017
Administrative Inspection · In-Service Inspection
Physical examination · Marine Safety Unit Duluth · USCG Great Lakes District (CGD-GL) · Activity 6310674
6 November 2017
Administrative Inspection · In-Service Inspection
Physical examination · Marine Safety Unit Duluth · USCG Great Lakes District (CGD-GL) · Activity 6302358
15 April 2017
Deficiency Check
Physical examination · Marine Safety Unit Duluth · USCG Great Lakes District (CGD-GL) · Activity 6124866
10 April 2017
Administrative Inspection
Administrative · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 6123024
6 January 2017
In-Service Inspection · Deficiency Check
Physical examination · Marine Safety Unit Duluth · USCG Great Lakes District (CGD-GL) · Activity 6067227
9 December 2016
In-Service Inspection
Physical examination · Marine Safety Unit Toledo · USCG Great Lakes District (CGD-GL) · Activity 6057087
31 July 2016
Administrative Inspection · Examination of Repairs
Physical examination · Marine Safety Unit Toledo · USCG Great Lakes District (CGD-GL) · Activity 5959575
29 July 2016
Damage Survey
Physical examination · Sector Detroit · USCG Great Lakes District (CGD-GL) · Activity 5956559
28 March 2016
Annual Inspection
Physical examination · Marine Safety Unit Duluth · USCG Great Lakes District (CGD-GL) · Activity 5842827
29 February 2016
Deficiency Check · Administrative Inspection
Physical examination · Marine Safety Unit Sturgeon Bay · USCG Great Lakes District (CGD-GL) · Activity 5830694
19 January 2016
In-Service Inspection · Examination of Repairs
Physical examination · Marine Safety Unit Duluth · USCG Great Lakes District (CGD-GL) · Activity 5799954
01 - Certificates & Documentation › 011 - Ships Certificates › Certificate of Inspection (COI)
Issued 18 June 2026
Resolved
No vessel may be navigated unless it has in its service, and onboard, the crew complement required by the COI; vessel does not currently meet the minimum manning specified on the COI. Vessel is currently short (01) 1st A/E from COI requirement. Vessel is permitted to transit from Gary, IN to Superior, WI to bring on board replacement 1st A/E.
Action required: 705 - Other - as specified
Resolved 22 June 2026
Resolution: First Assistant Engineer [name withheld] (MMC [withheld]) embarked the MV American Century.
02 - Structural Conditions › N/A - No Subsystem › Hull damage impairing seaworthiness
Issued 2 February 2026
No resolution recorded
A survey shall be made every time an accident occurs or a defect is discovered which affects the safety of the vessel. Damage to the #8 starboard ballast tank was discovered following an allision in January of 2026. 03 cracks were observed in the hull, and multiple frames on the inside of the tank were damaged and require crop/renew. Vessel is authorized to affect permanent repair to frames and temporary repairs to the hull via drill stop, gouge and weld as a temporary repair prior to departure for 2026 shipping season. Temporary repair is authorized until vessel enters dry dock in 2027 where permanent repair via crop/renew will be required.
Action required: 17 - Rectify deficiencies prior to departure
Due 27 March 2026 — due date passed with no resolution recorded
04 - Emergency Systems › N/A - No Subsystem › Abandon ship drills
Issued 2 February 2026
Resolved
Each lifeboat must be launched with its assigned crew and maneuvered in the water at least once every 3 months. Vessel was unable to execute drill because lifeboat was on the shore side of the vessel. Vessel is required to provide evidence of lifeboat drill within 30 days.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 27 April 2026
Resolved 6 April 2026
Resolution: Reviewed and accepted objective evidence of satisfactory drill.
02 - Structural Conditions › N/A - No Subsystem › Hull - corrosion
Issued 2 February 2026
Resolved
A survey shall be made every time an accident occurs or a defect is discovered which affects the safety of the vessel. During pressure testing of welds in cargo holds, water was observed leaking into the port side of cargo hold #1 from the adjacent ballast tank. It was discovered that a large portion of the area was substantially wasted beyond acceptable limits. Area will need to be surveyed and company will need to submit repair proposal. Vessel is authorized to temporarily leave dock to allow for the transit of another vessel and immediately return to the dock for survey and repair.
Action required: 17 - Rectify deficiencies prior to departure
Due 29 March 2026
Resolved 17 April 2026
Resolution: Permanent repairs made via replacement of entire strake and verified by ABS.
01 - Certificates & Documentation › 011 - Ships Certificates › Certificate of Inspection (COI)
Issued 24 December 2025
Resolved
Vessel is required to have the minimum manning as specified on the COI. Vessel does not currently meet the minimum manning specified on the COI. Company is required to find a suitable replacement and notify the local OCMI when qualified crew reports for duty.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 7 January 2026
Resolved 8 January 2026
Resolution: It was reported to MSU Duluth that crew vacancy had been filled.
01 - Certificates & Documentation › 011 - Ships Certificates › Certificate of Inspection (COI)
Issued 13 December 2025
Resolved
Master made notification to [name withheld], of crew shortage due to consent based discharge of AB Cepriano Matig, who departed the vessel on 12/12/2025. Vessel is authorized to operate with one less AB until arrival in Two Harbors, MN, on or about 12/15/25. If a replacement AB is not found, the Master shall contact the local OCMI to request further approval for temporary manning.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Resolved 6 February 2026
Resolution: Cleared outstanding deficiency. Vessel is now in winter layup in Cleveland, OH.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Operation of machinery
Issued 29 October 2025
Resolved
In addition to the emergency power source required under part 112 of this chapter, each self-propelled vessel must have at least two electric generating sources. Vessels reported the port generator breaker is not operating properly and will trip off without cause. Vessel to provide tech report to proper operation of breaker prior to departing the port of Duluth/Superior.
46CFR90.25-1
46CFR111.10-3
Action required: 17 - Rectify deficiencies prior to departure
Resolved 30 October 2025
Resolution: Faulty breaker replaced.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 8 May 2025
Resolved
All materials to be used in any of the work specified in the various sections of this part must be free from injurious defects and must have a workmanlike finish. The construction work must be executed in a workmanlike manner with proper tools or equipment and must be free from defects which would impair strength or durability.
There was a gap of about 1" between the boiler shell and the refractory near the burner nozzle on the top 1/2 to 3/4 of circle. Vessel must fill the gap per manufacture spec prior to operating the boilers.
52.01-40
Action required: 705 - Other - as specified
Resolved 19 August 2025
Resolution: Vessel filled the gap with "wet Pack" per manufacture instructions.
04 - Emergency Systems › N/A - No Subsystem › Man Overboard Drill (MOB)
Issued 20 March 2025
Resolved
The inspection shall be such as to insure that the vessel, as regards lifesaving appliances is in satisfactory condition and fit for the service for which it is intended. Unable to lower the lifeboat, or conduct a MOB drill on the vessel due to ice in the water.
46CFR91.25-10
46CFR97.15-35
46CFR199.45(b)(2)
Action required: 50 - Rectify deficiencies w/in 30 days
Due 20 April 2025
Resolved 16 April 2025
Resolution: Conducted MOB Drill
11 - Life Saving Appliances › N/A - No Subsystem › Lifeboats
Issued 20 March 2025
Resolved
The proper condition and operation of the survival craft and rescue boat launching appliances at loads ranging from light load to full load must be completed at every periodic and renewal inspection. The last load test was completed on 11AUG2020. Vessel is overdue for light load, and full weight test.
46CFR199.45(b)(1)
Action required: 50 - Rectify deficiencies w/in 30 days
Due 20 April 2025
Resolved 16 April 2025
Resolution: Conducted light load, and full load weight test.
07 - Fire Safety › N/A - No Subsystem › Fire pumps and its pipes
Issued 20 March 2025
Resolved
All piping, valves, and fittings shall meet the applicable requirements of subchapter F. The Fire main on deck, both port and STB side had a leak from flange fittings.
46 CFR 95.10-15(a)
Action required: 10 - Deficiency Rectified
Due 20 March 2025
Resolved 20 March 2025
Resolution: Crew tightened up the loose flange.
07 - Fire Safety › N/A - No Subsystem › Operation of Fire protection systems
Issued 20 March 2025
Resolved
Each section of firehose must be lined commercial firehose that conforms to Underwriters' Laboratories, Inc. Standard 19 or Federal Specification ZZ-H-451E. Four fire hoses were leaking and must be replaced.
46 CFR 95.10-10(n)(3)
Action required: 10 - Deficiency Rectified
Due 20 March 2025
Resolved 20 March 2025
Resolution: Crew replaced hoses.
11 - Life Saving Appliances › N/A - No Subsystem › Other (life saving)
Issued 20 March 2025
Resolved
A sufficient number of lifejackets must be carried for persons on watch and for use at remotely located survival craft stations. If watch stations, work stations, or work sites are remote from cabins, staterooms, or berthing areas and the immersion suits stowed in those locations, there must be, in addition to the immersion suits required under paragraph (a) of this section, enough immersion suits stowed at the watch stations, work stations, or work sites to equal the number of persons normally on watch in, or assigned to, those locations at any time. Vessels COI has a max of 33 persons allowed onboard, and states maximum number of lifejackets and immersion suits at 33. Immersion suits and lifejacket requirement should be 6 larger than the maximum number of crew because of watch station requirments onboard. Vessels max persons allowed reduced from 33 to 27.
46 CFR 96.06-1
46 CFR 199.273(b)
46 CFR 199.70(b)(1)(ii)
46 CFR 199.70(b)(2)(iv)
Action required: 705 - Other - as specified
Due 20 March 2025
Resolved 16 April 2025
Resolution: Vessel added required lifejackets and immersion suits, total onboard now is 39.
11 - Life Saving Appliances › N/A - No Subsystem › Immersion suits
Issued 21 February 2025
Resolved
Each cargo vessel must carry an immersion suit approved under approval series 160.171 of an appropriate size for each person on board. Vessel's COI requires 33 immersion suits. 01 Immersion suit was found with a wasted air hose, and was removed from service. Vessel maximum persons allowed is reduced by 1.
46 CFR 96.06-1
46 CFR 199.273(a)
Action required: 705 - Other - as specified
Due 20 March 2025
Resolved 16 April 2025
Resolution: Vessel replaced bad immersion suit.
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 28 May 2023
Resolved
In general compliance of prime movers with the rules promulgated by ABS will be considered as satisfactory evidence of structural and operational efficiency of prime movers. Vessel reported that one of two ship service generators is inoperable due to a faulty lube oil pump. Identify cause of casualty & repair to satisfaction of ABS and attending Coast Guard marine inspector, prior to departing port of Duluth/Superior. While transiting the port of Duluth/Superior, an adequate tug escort is required until rectification of this deficiency. 46 CFR 111.10-5(a)-"Old J"
AMENDED 29 May 23:
In general compliance of prime movers with the rules promulgated by ABS will be considered as satisfactory evidence of structural and operational efficiency of prime movers. Vessel reported that one of two ship service generators is inoperable due to a faulty lube oil pump. While transiting to St. Clair,MI utilize an adequate tug escort while in Duluth/Superior harbor and the St Clair river. Prior to departing St. Clair, MI, repair generator to satisfaction of ABS and attending Coast Guard marine inspector.
Condition: Improper/Lack of Maintenance
Action required: 15 - Rectify deficiencies by next port
Due 29 May 2023
Resolved 2 June 2023
Resolution: ABS attended and witnessed satisfactory repairs and testing.
09 - Working and Living Conditions › 092 - Working Conditions › Pipes, wires (insulation)
Issued 19 January 2023
Resolved
Piping whose temperature exceeds 150 degrees Fahrenheit, shall be suitably insulated. Steam piping missing insulation on forward bulkhead of engine room going to starboard heater. Insulate steam piping to the satisfaction of the attending MI prior to operation of auxiliary boilers.
46 CFR 96.03-1(a)
46 CFR 56.50-1(k)
Action required: 705 - Other - as specified
Resolved 17 April 2024
Resolution: Pipe was insulated, confirmed via pictures from [name withheld].
07 - Fire Safety › N/A - No Subsystem › Fire pumps and its pipes
Issued 26 December 2022
Resolved
Vessels must be equipped with independently driven fire pumps in accordance with Table 95.10-5(a). Vessel is over 1,500 gross tons and required to have a minimum of two fire pumps on board. Vessel master reported the strainer basket to their emergency fire pump froze over and cracked. Make permanent repairs to the satisfaction of attending Class (ABS) surveyor or Coast Guard marine inspector.
Action required: 15 - Rectify deficiencies by next port
Resolved 29 December 2022
Resolution: Attended vessel and witnessed testing of fire pump. Vessel crew replace basket housing and basket/filter with ship spare using existing bolted on connections.
04 - Emergency Systems › N/A - No Subsystem › Man Overboard Drill (MOB)
Issued 22 March 2022
Resolved
Vessel unable to launch lifeboat during annual fitout inspection due to hazardous ice conditions. Conduct MOB recovery drill and demonstrate launch, maneuvering, and recovery of the lifeboat. Drill to be witnessed by USCG Marine Inspector; or, provide date-stamped video of drill showing all aspects of evolution, to include operation of davit system components and on-water operations.
MSU Duluth contact: [email withheld]
Action required: 705 - Other - as specified
Due 22 April 2022
Resolved 11 May 2022
09 - Working and Living Conditions › 091 - Living Conditions › Sanitary Facilities
Issued 22 March 2022
Resolved
The following staterooms had broken ceramic floor tiles, loose of broken floor tiles, rust scale in shower stalls: 3RD mate portside floor and surround in bathroom; C/E stateroom ceramic floor tile pieces around bulkhead drain piping; 3A/E shower rust scale and cracked ceramic floor tiles; S/A stateroom; Ab port aft main floor and bathroom floor chipped and cracked floor tiles; Maint/AB port fwd shower drain.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 12 May 2022
Resolved 16 March 2023
Resolution: Conducted walkthrough of vessel noting repaired flooring in staterooms/bathrooms.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 23 December 2021
Resolved
There are requirements for fluid power transmission and control systems and appurtenances for bow thruster systems. During transit, the vessel reported their bow thruster inoperable. Determine cause of failure, effect repairs and prove proper operation of the bow thruster within 30 days to the satisfaction of Class [name withheld] attesting to the bow thruster operation.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 23 January 2022
Resolved 12 January 2022
Resolution: Received letter from vessel signed by Marine Superintendent and vessel Captain attesting the repair a full operation of the bow thruster.
09 - Working and Living Conditions › 092 - Working Conditions › Machinery
Issued 3 December 2021
Resolved
On the outboard auxiliary boiler, the control panel door's safety interlock in not operational.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 3 January 2022
Resolved 26 September 2022
Resolution: New control panel disconnect interlock has been installed.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 3 December 2021
Resolved
On the inboard boiler, one of the fuel shutoff solenoids is missing the electrical cover.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 3 January 2022
Resolved 17 December 2021
Resolution: Cover installed.
09 - Working and Living Conditions › 091 - Living Conditions › Ventilation (Accommodation)
Issued 26 March 2021
Resolved
Ventilation system in the accommodation spaces appears to be full of debris. Provide a plan to have the ventilation system professionally inspected. Provide inspection results to MSD Sturgeon Bay for further evaluation.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 25 April 2021
Resolved 16 April 2021
Resolution: HVAC technician inspected the ventilation system, sat.
07 - Fire Safety › N/A - No Subsystem › Fixed fire extinguishing installation
Issued 26 March 2021
Resolved
Fire hose on the reel behind the ECR is in need of replacing as per fire servicing company. Renew hose and reel if necessary.
Action required: 705 - Other - as specified
Resolved 10 May 2021
Resolution: Photographic evidence showing the hose reel has been renewed was rcvd by MSD Sturgeon Bay.
09 - Working and Living Conditions › 092 - Working Conditions › Guards - fencing around dangerous machinery parts
Issued 26 March 2021
Resolved
Heater in stbd fwd corner of anchor windlass room is missing its cover. Renew the cover or heater before use.
Action required: 705 - Other - as specified
Resolved 22 April 2021
Resolution: Per e-mail from master, requirement cleared.
09 - Working and Living Conditions › 092 - Working Conditions › Pipes, wires (insulation)
Issued 26 March 2021
Resolved
Observed nylon electrical cable penetration installed in an A-0 bulkhead, located above the engine room stbd main deck door. Remove and installed an acceptable and or approved metallic cable penetration as required by 46 CFR 92.07-10 Rectify within 30 days
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 26 April 2021
Resolved 13 April 2021
Resolution: An approve fire stop system was installed into a metal pipe penetration and the nylon end caps reinstalled.
09 - Working and Living Conditions › 092 - Working Conditions › Protection machinery
Issued 26 March 2021
Resolved
Observed in the main control room two monitoring cameras were not working. Repair or install an equivalent system which provides the engineering watch stander an automatic and remote control monitoring system which provides adequate means to monitor the engineering plant as required by 46 CFR 62.50-20. Rectify within 30 days
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 26 April 2021
Resolved 23 April 2021
Resolution: Master reported cameras were repaired and operating as designed. Requirement cleared
08 - Alarms › N/A - No Subsystem › General alarm
Issued 26 March 2021
Resolved
Noted several general alarms in the unloading tunnel were not working. Make repairs and demonstrate all general alarms in the unloading tunnel are working. As required per 46 CFR 113.25. Rectify before vessels departure.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 26 March 2021
Resolved 26 March 2021
09 - Working and Living Conditions › 092 - Working Conditions › Lighting (Working spaces)
Issued 26 March 2021
Resolved
Noted several emergency lights in the unloading tunnel were not illuminated, and several light fixtures missing covers. Make repairs and demonstrate all tunnel e-lights are proper illuminated and fixture covers are installed. As required by 46CFR 111.75-20. Rectify before vessels departure.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 26 March 2021
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 26 March 2021
Resolved
Noted emergency generator volt meter, when switched turned to B to C & A to C meter did not read proper phase voltage. Correct and demonstrate proper operation to CG [name withheld] with 30 days.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 26 April 2021
Resolved 26 March 2021
09 - Working and Living Conditions › 091 - Living Conditions › Sanitary Facilities
Issued 18 January 2021
Resolved
During the inspection of the accommodation spaces most of the staterooms had mold, rust, peeling paint, and in some cases broken tiles and cracked toilets. There is objective evidence that these substandard conditions are not being proactively managed. Clean mold and rust and renew broken tiles and cracked toilets.
Condition: Improper/Lack of Maintenance
Action required: 30 - Ship detained
Resolved 26 March 2021
Resolution: Showers and toilets were cleaned and renewed.
10 - Safety of Navigation › N/A - No Subsystem › Navigation bridge visibility
Issued 18 January 2021
Resolved
The wipers on the bridge need renewed. Also make sure the springs and arm have enough pressure on the window to operate properly.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 26 March 2021
Resolution: Wipers were renewed and the wipers made good contact with the windshield.
10 - Safety of Navigation › N/A - No Subsystem › Lights, shapes, sound-signals
Issued 18 January 2021
Resolved
The navigation light indicator panel sounds a trouble alarm when the lights are working properly. Replace LED lights with incandescent bulbs to ensure proper operation of the panel.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 26 March 2021
Resolution: New lights were installed wich allowed the panel to operate properly.
09 - Working and Living Conditions › 092 - Working Conditions › Guards - fencing around dangerous machinery parts
Issued 18 January 2021
Resolved
Renew the handles on the aft anchor cats paw and stbd fwd butler plate.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 26 March 2021
Resolution: Handles were renewed.
10 - Safety of Navigation › N/A - No Subsystem › Lights, shapes, sound-signals
Issued 18 January 2021
Resolved
Ensure proper navigation light operation is checked and logged in the official log book prior to sunset each day until the navigation light indicator panel is properly working.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 26 March 2021
Resolution: Light panel is operating properly.
11 - Life Saving Appliances › N/A - No Subsystem › Inflatable liferafts
Issued 18 January 2021
Resolved
Inflatable liferafts are stowed so that launching them requires them to be lifted more than 1 foot. Provide a plan to minimize the distance the life rafts need to be lifted iin order to be launched.
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 26 March 2021
Resolution: Liferaft cradels were elevated to prooper height.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 18 January 2021
Resolved
Observed hydraulic fluid leaking from the stbd inboard and port inboard steering gear pump discharge lines. Engineers stated they had conducted a test the day before, and no leaks were observed. Informed steering gear units were serviced during this past winter.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 26 March 2021
Resolved 26 March 2021
Resolution: 1st engineering retighten loose bolts and corrected piping misaligned piping. Thereafter all pumps tested, with no leaks observed.
02 - Structural Conditions › N/A - No Subsystem › Hull - cracking
Issued 15 October 2020
Resolved
Temporary repairs were made to a halfmoon shaped crack, approx. 12" long, located under the port anchor pocket. Permanent repairs must be made to the satisfaction of the CG or Class at the next dry-dock, scheduled for NLT 04FEB2021.
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Due 4 February 2021
Resolved 25 January 2021
Resolution: Crack was cropped and renewed during vessel drydock in Jan 2021.
11 - Life Saving Appliances › N/A - No Subsystem › Lifeboats
Issued 29 July 2020
Resolved
Vessel was unable to perform full load and light load weight tests of lifeboat due to mooring arrangement with another vessel preventing lowering of boat. Perform lifeboat weight testing as required.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 12 August 2020
Resolved 11 August 2020
Resolution: Witnessed tests at CN Dock; Two Harbors, MN
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 29 July 2020
Resolved
Both boilers (currently off-line) are due or fireside/waterside inspection and hydrostatic testing prior to bringing each boiler on-line for the season.
Action required: 705 - Other - as specified
Resolved 13 November 2020
Resolution: MSU Cleveland conducted satisfactory fireside & waterside inspection of aux. boilers, 10/16/2020. MSU Duluth witnessed satisfactory hydro test of both aux boilers on 13NOV2020.
07 - Fire Safety › N/A - No Subsystem › Fire-dampers
Issued 29 July 2020
Resolved
Fire dampers for engine room on the main deck port side and the one middle damper on the starboard side gaskets are wasted. Replace gasket material to the original state to ensure proper ventilation closer.
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 11 August 2020
Resolution: Examined satisfactorily at CN Dock; Two Harbors, MN.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 7 July 2019
Resolved
Make repairs to the #2 generator to ensure it can be placed in parallel mode with other generators to the satisfaction of U.S. Coast Guard Officer In Charge, Marine Inspection prior to departure from Silver Bay, MN.
Action required: 17 - Rectify deficiencies prior to departure
Due 9 July 2019
Resolved 9 July 2019
Resolution: Witnessed proper operation of generator after repairs.
11 - Life Saving Appliances › N/A - No Subsystem › Lifeboats
Issued 21 March 2019
Resolved
Vessel was unable to lower the open Life Boat, as well as get the life boat underway during the Annual COI inspection due to location at the dock. Vessel is required to lower the life boat into the water and have crew maneuver the life boat in the water in the next 30 days.
Condition: Invalid
Action required: 705 - Other - as specified
Due 11 May 2019
Resolved 3 May 2019
Resolution: Vessel was able to launch and maneuver lifeboat successfully.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 30 November 2018
Resolved
All systems of a marine engineering nature shall be in
accordance with the requirements of sub-chapter F. The
vessels water cooled bearing on the port tail shaft is
leaking more than expected water. Vessel secured port
tail shaft in route to St. Claire. Make repairs and test
to the satisfaction of U.S. Coast Guard Officer In
Charge, Marine Inspection prior to departing St. Claire.
Action required: 705 - Other - as specified
Due 7 December 2018
Resolved 3 December 2018
Resolution: Received statement from C/E attesting to repairs and satisfactory tests.
Engineering › Steam Boiler (auxiliary/waste heat) › Combustion Chamber
Issued 21 March 2018
Resolved
Prior to being placed back into service, Auxiliary Boiler #S-4600 must have its mounting removed for inspection, and have both a fireside and waterside inspection all conducted by a USCG Marine Inspector. Boiler is past due for these inspections.
Condition: Invalid
Action required: 705 - Other - as specified
Due 21 May 2018
Resolved 4 October 2018
Resolution: Counducted Fireside, Waterside inspecitons and mountings were removed for inspection.
Operations/Management › Drills/Instruction › Launching/Recovery of Survival Craft
Issued 21 March 2018
Resolved
Per D9 policy direction, USCG Marine Inspector shall witness the vessel's lifeboat launch, operate and be recovered in the water. Weather conditions prohibited this, at the time of inspection, from being safely conducted. Vesseul requested 30 day extension due to adverse weather conditions, extended additional 30 days.
Action required: 705 - Other - as specified
Due 21 May 2018
Resolved 6 August 2018
Resolution: Conducted sat u/w drill
Engineering › Reduction Gearing/Clutches › Shaft
Issued 10 April 2017
Resolved
Vessel may proceed to Superior, Wi under the power of 3 engines. Upon arrival effect permanent repairs to the starboard outboard quill shaft and pilot bearing. Repairs shall be completed to the satisfaction of an attending Coast Guard Marine Inspector. 46 CFR 50.05-10
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Due 24 April 2017
Resolved 15 April 2017
Resolution: New quill shaft and pilot bearing installed and clutch tested. Rolled shaft, all systems satisfactory. repairs complete.
Fire Fighting › Fixed CO2 Fire Extinguishing System › Operating Controls
Issued 10 March 2017
Resolved
Vessel original CO2 system drawings were approved with a 60 second time delay. At some point a 30 second was installed. Requirement is to replace with a 60 as approved in original drawing.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 10 April 2017
Resolved 6 April 2017
Resolution: Observed new from factory 60 second delay installed.
Construction/Loadline › Hull › Hull Plating
Issued 29 July 2016
Resolved
Make permanent repairs as original to damaged, inset area of bow section on centerline just below the anchor pockets, to include internal structure centerline longitudinal and transverse support shell framing.
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Due 29 July 2016
Resolved 2 August 2016
Resolution: Effected satisfactory permanent repairs to damage areas