MAURY USCG vessel records Sign in
← All vessels

BW SUND

BW SUND is a 1981 tank ship. The Coast Guard has recorded 29 inspections since 1985, most recently in February 2009, along with 16 deficiencies and 6 operational controls.

Records from 1985 to 2009. Most recent: inspection, 26 February 2009.

Built
1981
Last inspected
26 February 2009
Documentation
Not in the documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

7420077 View on MarineTraffic leaves Maury; a third-party site, nothing from it is stored here
Flag
NORWAY
—
Maury page id
psix-54917

Inspections, by type

…with no type recorded13
Years with a record 11 calendar years (1985–2009)
The 29 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

This record may be incomplete: the most recent inspection recorded for this vessel was 17 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Tank Ship class in Maury's sources begin in 1980.

Documentation record

Tonnage as PSIX records it43849 - Convention (Subpart B), Gross Ton
43849 - Simplified, Gross Ton
18807 - Simplified, Net Ton
55303 - Dead Weight, Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.

Radio station licence

No FCC ship-station licence is recorded against this Official Number in the file of 6 September 2026. That is a fact about the licence file, not about the radio.

Inspection history · 29

26 February 2009 Deficiency Check
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 3424459
7 February 2009 Type not recorded
No type recorded · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 3402584
7 February 2009 Ballast Water Examination · COC-GAS Renew · ISPS II Exam
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 3413745
30 January 2009 Type not recorded
No type recorded · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 3402800
27 May 2007 COC-GAS Renew · Ballast Water Examination · ISPS II Exam
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 2942301
26 May 2007 Type not recorded
No type recorded · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 2941159
26 October 2005 Type not recorded
No type recorded · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 2525508
16 September 2005 Deficiency Check
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 2494179
17 June 2005 ISPS II Exam · COC-GAS Renew · Ballast Water Examination
Physical examination · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 2393884
16 June 2005 Type not recorded
No type recorded · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 2396570
5 December 2003 Deficiency Check
Physical examination · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 1959569
22 October 2003 Annual Inspection
Physical examination · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 1933951
15 November 2002 Administrative Inspection
Administrative · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 1705977
22 August 2002 Security Inspection
Physical examination · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 1665065
20 August 2002 Letter of Compliance (Initial/Renewal)
Administrative · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 1663236
20 August 2002 Security Inspection
Physical examination · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 1665032
3 June 2000 Type not recorded
No type recorded · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 278437
3 June 2000 Letter of Compliance (Initial/Renewal)
Administrative · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 1049524
25 June 1998 Type not recorded
No type recorded · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 416576
2 March 1998 Type not recorded
No type recorded · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 412981
2 March 1998 Letter of Compliance (Initial/Renewal)
Administrative · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 1116649
26 August 1996 Type not recorded
No type recorded · Marine Safety Detachment Kenai · USCG Arctic District (CGD-A) · Activity 395627
20 August 1996 Type not recorded
No type recorded · Marine Safety Detachment Kenai · USCG Arctic District (CGD-A) · Activity 76168
2 May 1996 Type not recorded
No type recorded · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 390677
2 May 1996 Letter of Compliance (Initial/Renewal)
Administrative · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1082666
14 October 1991 Certificate of Compliance
Administrative · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 938150
21 July 1988 Type not recorded
No type recorded · COTP HOUSTON · USCG Heartland District (CGD-H) · Activity 511823
21 July 1988 Certificate of Compliance
Administrative · MIO HOUSTON · USCG Heartland District (CGD-H) · Activity 1340957
9 January 1985 Type not recorded
No type recorded · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 300779

Deficiency record · 16

Deck/Cargo › Inert Gas System › Inert Gas Generator (IGG)
Issued 7 February 2009 Resolved
Vessel to submit class report attesting repir of IGS system
Action required: 705 - Other - as specified
Due 7 February 2009
Resolved 7 February 2009
Resolution: Received class report attesting IGS is working properly
Communications › Radio Communications › Satellite Communications Capability
Issued 7 February 2009 Resolved
Inmarsat B inoperable, vessel must repair prior to next US port to the satisfaction of class or Flag.
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 26 February 2009
Resolution: Received class report which stated - Even though the inmarsat B is not part of the by SOLAS governed GMDSS installation, but rather is a mean of communication for commercial use primarily, it can be confirmed that the installation was repaired and has be
Fire Fighting › Automatic Sprinkler System › Piping
Issued 7 February 2009 Resolved
Nozzle cooling for the main engine ruptured, vessel to make temporary repairs prior to departure and make permanent repairs prior to next US port to the satisfaction of class or Flag.
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 26 February 2009
Resolution: Received class report which stated – The nozzle cooling pipe was temporarily repaired at Tallaboa. The flange to flange pipe section has since been dismantled and a complete new section of nozzle cooling pipe fitted.
Deck/Cargo › Inert Gas System › Inert Gas Generator (IGG)
Issued 30 January 2009 Resolved
Inoperable IGG system. The cause is unknown.
Action required: 705 - Other - as specified
Resolved 7 February 2009
Resolution: Class surveyor attested to sat repair of IGG system and provided report.
Communications › Radio Communications › Satellite Communications Capability
Issued 30 January 2009 Resolved
Inperable SatCom INMARSAT B.
Action required: 705 - Other - as specified
Resolved 26 February 2009
Resolution: Received class report which stated - Even though the inmarsat B is not part of the by SOLAS governed GMDSS installation, but rather is a mean of communication for commercial use primarily, it can be confirmed that the installation was repaired and has be
Engineering › Steering Gear System › Pump
Issued 17 June 2005 Resolved
The steering gear pump leaks hydraulic fluid from a failed shaft seal. SOLAS 74 amended, Chapter I regulation 11
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 24 June 2005
Resolved 17 September 2005
Resolution: CLASS SOCIETY SATISFIED
Engineering › Sea-water System (primary cooling) › Pump
Issued 17 June 2005 Resolved
The discharge piping on the #2 main sea water pump is temporary patched. Make permanent repairs to the satisfaction of class. SOLAS 74 amended, Chapter I regulation 11.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 24 June 2005
Resolved 17 September 2005
Resolution: CLASS SOCIETY SATISFIED
Engineering › Sea-water System (primary cooling) › Piping
Issued 17 June 2005 Resolved
The cooling water pipe to the midship plant is temporary patched and seeping. Make permanent repairs to the satisfaction of class. SOLAS 74 Amended, Chapter I regulation 11.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 24 June 2005
Resolved 17 September 2005
Resolution: CLASS SOCIETY SATISFIED
Electrical › Electrical Distribution System (service) › Cable
Issued 17 June 2005 Resolved
The cooling water to the midship plant is leaking at a flange and causing excessive deterioration of a high voltage cable. SOLAS 74 amended, Chapter II-1 regulation 27.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 24 June 2005
Resolved 17 September 2005
Resolution: CLASS SOCIETY SATISFIED
Electrical › Electric Generation Source (emergency) › Generator
Issued 17 June 2005 Resolved
The hydraulic starting mechanism for the emergency generator has a notable hydraulic leak. SOLAS 74 amended, Chapter I regulation 11.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 24 June 2005
Resolved 17 September 2005
Resolution: CLASS SOCIETY SATISFIED
Electrical › Electric Generation Source (emergency) › Generator
Issued 17 June 2005 Resolved
There is a notable jacket water leak on the emergency generator. SOLAS 74 amended, Chapter I regulation 11.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 24 June 2005
Resolved 17 September 2005
Resolution: CLASS SOCIETY SATISFIED
Electrical › Electric Generation Source (emergency)
Issued 22 October 2003 Resolved
Provide class report attesting to the proper operation of the emergency generator automatic start. Until auto-start is repaired, emergency generator room shall be manned in restricted waters.
Condition: Unknown
Action required: 15 - Rectify deficiencies by next port
Resolved 5 December 2003
Resolution: CLEARED VIA BV CLASS REPORT.
Construction/Loadline › Structures
Issued 22 October 2003 Resolved
Make temporary repairs to three holes in bulkhead between motor and compressor rooms. Provide class report attesting to satisfactory permanent repairs to holes prior to 22Dec03. LEGACY COMPONENT DESC: Transverse Bulkhead
Condition: Design Flaw
Due 22 December 2003
Resolved 5 December 2003
Resolution: CLEARED VIA BV CLASS REPORT.
Deck/Cargo
Issued 22 October 2003 Resolved
Provide class report addressing the absence of self-closing devices on air-lock doors prior to next U.S. port.
Condition: Design Flaw
Action required: 15 - Rectify deficiencies by next port
Resolved 5 December 2003
Resolution: CLEARED VIA BV CLASS REPORT.
Engineering › Generator (propulsion/auxiliary-electric)
Issued 20 August 2002 Resolved
Provide class society report as to the proper repair and operation of #5 aux. generator to [name withheld] No later than 01 Nov 02.
Condition: Unknown
Due 1 November 2002
Resolved 15 November 2002
Resolution: Received DNV class report.
Engineering
Issued 14 October 1991 Resolved
REPAIR OILY WATER SEPARATOR/ALARM AND PROVE OPERATION TO COGNIZANT [name withheld] TO U.S. WATERS.
Condition: Unknown
Due 14 October 1991
Resolved 14 October 1991

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.