MAURY USCG vessel records
← All vessels

THELMA DALE IV

THELMA DALE IV is a 1980 passenger vessel (inspected). The Coast Guard has recorded 18 inspections since 2016, most recently in September 2025, along with 58 deficiencies.

Records from 2016 to 2025. Most recent: inspection, 3 September 2025.

Built
1980
Last inspected
3 September 2025
Documentation
Valid · documentation file of 10 August 2026
Controls
None recorded without a removal date

Everything above is free. The detail below — the inspection history, the deficiency record and the documentation record — is Professional, $39 a month. Sign in.

Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 2016.

Inspection record

Last inspected 3 September 2025
…with no type recorded1
Operational controls None recorded without a removal date
Years with a record 10 calendar years (2016–2025)
Every line above is a count of records the US Coast Guard wrote, or a date it recorded. A blank resolution means none was recorded in this data; it does not establish that a deficiency is outstanding. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Identity

WAC5780
Flag
UNITED STATES
Maury page id
psix-54922

Documentation record

Registered dimensions (L × B × D)71.0 ft × 20.2 ft × 6.1 ft
Registered tonnagegross 84 / net 57
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderLYDIA YACHTS INC. · STUART, FL, UNITED STATES · built 1980
Hull materialWood
PropulsionDiesel Reduction
Hull shapeUNSPECIFIED
Hull configurationUNSPECIFIED
Hailing portLEWES, DE
Trade endorsementsCoastwise, unrestricted, Fishery
DocumentationValid · issued 1 April 2026 · expires 30 April 2027
Service, as the file records itPassenger (Inspected)
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it84 - Regulatory (Subpart C or D), Gross Ton
57 - Regulatory (Subpart C or D), Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 August 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
Professional
Detail on this page

18 inspections, each with its date, unit and type; 58 deficiencies with the resolution recorded against each; the documentation record: dimensions, tonnage, builder, hailing port, endorsements, dates. The counts in the summary above are the same counts, and they are free.

$39 a month or $299 a year, every vessel page, cancel any time. Founding rate $19.99 a month for life, for the first 200 subscribers. Plans Sign in

Maury does not score, rate or grade vessels, at any price.

Vessel history report

A report is not offered for this hull. Its record holds only 2 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. What a sparse-record report looks like.

Inspection history · 18

3 September 2025 Annual Inspection · Deficiency Check
Physical examination · Marine Safety Unit Lewes · USCG East District (CGD-E) · Activity 8217936
29 April 2025 Deficiency Check · Internal Structural Exam · Drydock Exam
Physical examination · Marine Safety Unit Lewes · USCG East District (CGD-E) · Activity 8111696
10 September 2024 Annual Inspection · Deficiency Check
Physical examination · Marine Safety Unit Lewes · USCG East District (CGD-E) · Activity 7999932
12 September 2023 Deficiency Check · Annual Inspection
Physical examination · Marine Safety Unit Lewes · USCG East District (CGD-E) · Activity 7768045
28 April 2023 Deficiency Check · Internal Structural Exam · Drydock Exam
Physical examination · Marine Safety Unit Lewes · USCG East District (CGD-E) · Activity 7674729
7 June 2022 COI Inspection · Administrative Inspection
Physical examination · Marine Safety Unit Lewes · USCG East District (CGD-E) · Activity 7470735
25 January 2022 Type not recorded
No type recorded · Marine Safety Unit Lewes · USCG East District (CGD-E) · Activity 7385446
20 October 2021 Deficiency Check
Physical examination · Marine Safety Unit Lewes · USCG East District (CGD-E) · Activity 7336614
7 September 2021 Annual Inspection · Deficiency Check
Physical examination · Marine Safety Unit Lewes · USCG East District (CGD-E) · Activity 7306059
28 April 2021 Drydock Exam · Deficiency Check · Internal Structural Exam
Physical examination · Marine Safety Unit Lewes · USCG East District (CGD-E) · Activity 7184829
8 September 2020 Deficiency Check · Annual Inspection
Physical examination · Marine Safety Unit Lewes · USCG East District (CGD-E) · Activity 7052894
13 January 2020 In-Service Inspection
Physical examination · Marine Safety Unit Lewes · USCG East District (CGD-E) · Activity 6888678
9 September 2019 Deficiency Check · Annual Inspection
Physical examination · Marine Safety Unit Lewes · USCG East District (CGD-E) · Activity 6807202
2 April 2019 Internal Structural Exam · Hull Examination · Examination of Repairs
Physical examination · Marine Safety Unit Lewes · USCG East District (CGD-E) · Activity 6654588
11 September 2018 Annual Inspection · Deficiency Check
Physical examination · Marine Safety Unit Lewes · USCG East District (CGD-E) · Activity 6537604
9 June 2017 COI Inspection · Deficiency Check
Physical examination · Marine Safety Unit Lewes · USCG East District (CGD-E) · Activity 6167433
15 March 2017 Examination of Repairs · Hull Examination · Internal Structural Exam
Physical examination · Marine Safety Unit Lewes · USCG East District (CGD-E) · Activity 6105861
8 September 2016 Annual Inspection
Physical examination · Marine Safety Unit Lewes · USCG East District (CGD-E) · Activity 5994430

Deficiency record · 58

02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 3 September 2025 Resolved
At each inspection the hull shall be examined. Forepeak deck stbd side, first frame outboard of deck clamp wood is wrotten.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 19 September 2025
Resolution: O/O removed a portion of the deck and bullwark that had rotten wood. Treated 02 frames outboard of deck clamp, replaced deck and bulwark.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Auxiliary engine
Issued 3 September 2025 Resolved
All machinery shall be checked and operational. Port generator is inoperable. 46CFR176.25-10
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 19 September 2025
Resolution: Port generator tested and is fully operational.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 3 September 2025 Resolved
The condition of the vessel and equipment shall be acceptable. Port exhaust leak and protective lagging missing. 46CFR182.430
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 19 September 2025
Resolution: Protective lagging installed on port engine exhaust. Leak secured.
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 3 September 2025 Resolved
At each inspection the hull and its through fittings shall be examined. Sewage overboard discharge line leaking into the lazerrete space. 46CFR177.800
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 19 September 2025
Resolution: O/O changed out threaded connection above the shutoff valve and tightend all fittings. MI inspected vessel underway at full ahead speed with valve open and closed. Sewage discharge pipe is tight and leak free.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 3 September 2025 Resolved
The condition of the vessel and it's equipment shall be acceptable to the [name withheld] leak identified outboard STBD engine. 46CFR176.01-10
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 3 October 2025
Resolved 19 September 2025
Resolution: Oil leak secured.
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 10 September 2024 Resolved
Switchboards shall be dry and adequately protected. Breaker panel on the bridge does not lock and has an opening on the cover. 46CFR183.05-15
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 11 September 2024
Resolution: Vessel fixed the breaker panel cover to fully close and latch shut.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 10 September 2024 Resolved
The inspector shall examine and test all items in the ship's outfit. Vessel's hydraulic line for the anchor has a leak in the forepeak compartment. 46CFR176.25-40
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 11 September 2024
Resolution: Hydraulic lines tightened, no longer leaking.
11 - Life Saving Appliances › N/A - No Subsystem › Launching arrangements for survival craft
Issued 10 September 2024 Resolved
Stowing of life floats must allow easy launching. Life float painter lines were tangled and not readily accessible for inspection. 46CFR180.20-1
Condition: Improper Installation
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 11 September 2024
Resolution: Painter lines untangled and ready for immediate deployment.
05 - Radio Communications › N/A - No Subsystem › Main installation
Issued 10 September 2024 Resolved
A ship station license is granted for operation of all maritime servieces transmitting equipment. VSL's ship station license is expired. 47CFR80.13
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 11 September 2024
Resolution: Vessel provided ship station license for vessel and placed onboard vessel.
09 - Working and Living Conditions › 092 - Working Conditions › Warning notices
Issued 10 September 2024 Resolved
Oil pollution prevention placard required to be posted. Vessel missing placard. 33CFR155.450
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 11 September 2024
Resolution: Vessel placed oil pollution placard onboard vessel.
18 - Maritime Labour Convention (Not Applicable to PSC Exams conducted in the U.S.) › N/A - No Subsystem › Other (Conditions of employment)
Issued 12 September 2023 Resolved
For each marine casualty required to be reported, the owner, master or PIC of the vessel shall determine whether there is any evidence of alcohol or drug use by individuals directly involved in the incident. Vessel is required to have means to test 03 crewmembers for alcohol. Vessel's alcohol test strips are expired. 46CFR185.210
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 12 September 2023
Resolved 4 October 2023
Resolution: VSL has 06 on board and within expiration date
07 - Fire Safety › N/A - No Subsystem › Oil accumulation in engine room
Issued 12 September 2023 Resolved
At each inspection the bilges and other spaces shall be free from excessive accumulation of oil, trash, debris, or other matter that might creae a fire hazard. Hydraulic oil accumulated under operating station where batteries, motors, and many electrical wires are located. O/O clean this space free of hydraulic fuel, remove soiled material, and have ready for inspection. 46CFR176.830
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 12 September 2023
Resolved 4 October 2023
Resolution: O/O cleaned hydraulic oil residue, MI verfied no active leaks.
07 - Fire Safety › N/A - No Subsystem › Fire pumps and its pipes
Issued 12 September 2023 Resolved
A power driven fire pump shall be installed with a minimum capacity of 50 gallons per minute at a pressure not less than 60 psi. Vessel's water intake valve frozen. O/O shall prepare fire pump, valve and piping for MI to verify proper operation. 46CFR181.10-1
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 12 September 2023
Resolved 4 October 2023
Resolution: O/O replaced frozen ball valve with a gate valve. MI vefified adequate pressure at fire stations.
07 - Fire Safety › N/A - No Subsystem › Means of escape
Issued 12 September 2023 Resolved
All escape hatches and other emergency exits shall be marked on both sides using at least 1 inch letters: "Emergency Exit, Keep Clear". 46CFR185.30-15
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 12 September 2023
Resolved 4 October 2023
Resolution: O/O labeled second deck escape hatch with block lettering "Emergency Escape, keep clear"
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 12 September 2023 Resolved
All electrical installations shall be to the satisfaction of the [name withheld] acid leak in the STBD E/R battery bank, and corrosion in the Port E/R battery bank. O/O shall make E/R battery installation corrections ot the satisfaction of the attending MI. 46CFR183.01-15
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 12 September 2023
Resolved 4 October 2023
Resolution: O/O wrapped exposed wiring at STBD bank, removed corrosion at port bank
02 - Structural Conditions › N/A - No Subsystem › Steering gear
Issued 12 September 2023 Resolved
All vessels shall be provided with suitable steering apparatus. Vessel's steering hydraulic line has a hydraulic leak in the lazarette space. 46CFR182.30-1
Condition: Damaged By Earlier Event
Action required: 701 - Prior to carriage of passengers/cargo
Due 12 September 2023
Resolved 4 October 2023
Resolution: O/O secured fittings in hydraulic line in lazerette. MI verified under power, no leakage occured.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 12 September 2023 Resolved
Exhaust piping shall be gas-tight throughout its length. Vessel's port engine water cooled exhaust pipe has a water leak at a coupling connection. 46CFR182.20-20
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 12 September 2023
Resolved 4 October 2023
Resolution: O/O tightened coupling. MI verified no loss of water on exhaust pipe.
14 - Pollution Prevention › 144 - MARPOL Annex IV (Not Applicable to PSC Exams conducted in the U.S.) › Sewage discharge connection
Issued 12 September 2023 Resolved
At each inspection the inspector shall examine and test all items which are required by the regulations. Vessel's sewage discharge line overboard is leaking fluid in the in the aft compartment outboard the sewage holding tank. 46CFR176.25-40
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 12 September 2023
Resolved 4 October 2023
Resolution: O/O took apart couplings in overboard sewage discharge line, re-tighened all components on line to include couplings. MI verified no leaks present
09 - Working and Living Conditions › 092 - Working Conditions › Other (accident prevention)
Issued 12 September 2023 Resolved
At each inspection the MI shall require that all ovserved unsafe practices and hazardous situations be corrected, and that there are no accumulation of oil that may create a fire hazard. Port generator had a fuel leak at the fuel filter. 46CFR176.25-50
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 12 September 2023
Resolved 4 October 2023
Resolution: MI verified fuel filter and all components of the port generator did not leak.
05 - Radio Communications › N/A - No Subsystem › Satellite EPIRB 406MHz/1.6GHz
Issued 12 September 2023 Resolved
Each vessel that operates on the high seas must have on board a FCC Type Category 1, 406 MHz EPIRB, installed to automatically float free and activate. Vessel's EPIRB battery and HRU unit expired. 46CFR180.64
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 12 September 2023
Resolved 4 October 2023
Resolution: O/O replaced EPIRB battery and HRU.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 12 September 2023 Resolved
A vessel great than 65' in length must carry a minimum of 3 24" ring life buoy with suitable grab lines and name of the vessel in capital letters. Vessel's ring life buoy mounted on the stern did not have the vessel's name. The grab line was deteriated and needs replaced. 46CFR180.70, 46CFR185.604
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 12 September 2023
Resolved 4 October 2023
Resolution: Vessel's name stenciled on life ring, MI verified grab line in sat condition.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 12 September 2023 Resolved
Placards containing instructions for donning and use of life jackets must be posted in a conspicuous place. Vessel has two types of lifejackets and currently has donning instructions for one of them. 46CFR185.516
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 12 September 2023
Resolved 4 October 2023
Resolution: MI verfied both types of life jackets on board now have donning instructions clearly posted.
01 - Certificates & Documentation › 013 - Documents › Stability Information Booklet
Issued 12 September 2023 Resolved
The COI and Stability Letter shall be framed under glass and posted in a conspicuous place. MI noted vessel did not have COI nor Stability Letter posted in a conspicuous location. 46CFR176.01-40, 46CFR176.306
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 12 October 2023
Resolved 4 October 2023
Resolution: O/O posted both in consipicuous location behind glass frame.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 28 April 2023 Resolved
Rubber shaft bearings must be renewed when any water groove is found to be half the original depth. Both port and starboard shaft bearings have excessive wear and require replacement. 46CFR176.670
Action required: 705 - Other - as specified
Due 28 April 2023
Resolved 28 April 2023
Resolution: Owner installed two new cutlass bearings.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Covers (hatchway-, portable-, tarpaulins, etc.)
Issued 28 April 2023 Resolved
A hatch exposed to the weather must be watertight. Hatch leading to steering compartment missing gasket. 46CFR179.360
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Due 28 April 2023
Resolved 9 June 2023
Resolution: Received picture of gasket properly sealed in hatch creating a watertight connection.
07 - Fire Safety › N/A - No Subsystem › Fire pumps and its pipes
Issued 17 June 2022 Resolved
A power-driven fire pump shall be installed on each mechanically propelled which is permitted to carry 49 or more passengers. Vessel’s fire pump was in operable.
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Due 17 June 2022
Resolved 17 June 2022
Resolution: Satisfactory test conducted on the vessel's fire pump.
14 - Pollution Prevention › 144 - MARPOL Annex IV (Not Applicable to PSC Exams conducted in the U.S.) › Sewage discharge connection
Issued 7 September 2021 Resolved
When operating a vessel on a body of water where the discharge of untreated sewage is prohibited by the Environmental Protection Agency under 40 CFR 140.3, the operator must secure each Type III device in a manner which prevents discharge of sewage. Acceptable methods of securing the device include -(1) Closing each valve leading to an overboard discharge and removing the handle;(2) Padlocking each valve leading to an overboard discharge in the closed position; or(3) Using a non-releasable wire-tie to hold each valve leading to an overboard discharge in the closed position. Vessel’s type III MSDS holding tank was found open. Install locking devices to prevent the discharge of sewage prior to operating within 3nm.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 21 September 2021
Resolved 20 October 2021
Resolution: Verified both bathroom doors now have locking handles installed. Master keeps the doors locked when passengers are onboard and unlocks them when the vessel is outside 3 miles on coastwise voyages.
09 - Working and Living Conditions › 092 - Working Conditions › Machinery
Issued 7 September 2021 Resolved
No major repairs or alterations affecting the safety of, the vessel with regard to the hull machinery, or equipment, shall be made without the knowledge and approval of the Officer in Charge Marine Inspection. Proposed alterations shall be approved by the Officer in Charge Marine Inspection, before work is started. Drawings, sketches or written specfications describing the alterations in detail may be required by the Officer in Charge, Marine Inspection. Vessel had a generator installed without prior approval. Submit drawings and written specifications for installation of starboard generator prior to operating starboard generator.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 21 September 2021
Resolved 21 September 2021
Resolution: Received required documentation from O/O
02 - Structural Conditions › N/A - No Subsystem › Steering gear
Issued 7 September 2021 Resolved
At each initial and subsequent inspection for certification and reinspectien the marine inspector shall examine and test the main and auxiliary steering apparatus to the extent necessary to determine that its condition is satisfactory and that it is fit for the service intended. The vessel’s starboard rudder packing leaks excessively when observed hard over.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 21 September 2021
Resolved 20 October 2021
Resolution: Did not conduct underway verification. However, discussed with vessel mechanic how rudder post packing was repaired and noted condition of packing nut.
05 - Radio Communications › N/A - No Subsystem › Satellite EPIRB 406MHz/1.6GHz
Issued 7 September 2021 Resolved
Each vessel that operates on the high seas, or that operates beyond three miles from the coastline of the Great Lakes, must have on board a FCC Type Accepted Category 1, 406 MHz EPIRB, installed to automatically float free and activate. Vessel’s EPIRB battery and HRU are expired. Vessel limited to no more than three nautical miles from shore.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 21 September 2021
Resolved 8 September 2021
Resolution: New EPIRB and HRU provided on board.
09 - Working and Living Conditions › 092 - Working Conditions › Other (accident prevention)
Issued 7 September 2021 Resolved
The marine employer must have a sufficient number of alcohol testing devices readily accessible onboard the vessel to determine the presence of alcohol in the system of each individual who was directly involved in the Serious Marine Incident (SMI), unless the required alcohol tests can be accomplished within 2 hours from the time of occurrence of the SMI. Vessel's COI authorizes operations on an Oceans Route and the alcohol testing devices provided are expired. Vessel is limited to a route and time where alcohol testing can be completed within 2 hours of an SMI.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 21 September 2021
Resolved 8 September 2021
Resolution: New, valid, alcohol testing devices are provided on board.
09 - Working and Living Conditions › 092 - Working Conditions › Other (accident prevention)
Issued 7 September 2021 Resolved
No marine employer shall engage or employ any individual to serve as a crewmember unless the individual passes a chemical test for dangerous drugs for that employer. Vessel’s crew member does not have pre-employment testing results.
Condition: Placed in Improper Service
Action required: 16 - Rectify deficiencies w/in 14 days
Due 21 September 2021
Resolved 20 October 2021
Resolution: Reviewed updated company random drug testing enrollement list with Maritime Consortium. Deckhand from 07SEP2021 inspection is now listed as "full compliance".
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 7 September 2021 Resolved
Electrical installations and equipment that will result in a vessel that is reasonably safe from fire caused by and/or originating in electrical equipment, and reasonably safe from eleotrical shock-of personnel. Numerous dead end wires exist on the vessel. In the third compartment dead end wires in and around the CO2 bottles, in the engine room, dead end wires above the starboard generator, block heater on port engine, and in the steering room dead end wires on the vessel’s ventilation fan. Remove all dead end wires to the satisfaction of the attending marine inspector.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 21 September 2021
Resolved 20 October 2021
Resolution: Verified the identified dead end wires have been corrected.
10 - Safety of Navigation › N/A - No Subsystem › Record of drills and steering gear tests
Issued 7 September 2021 Resolved
The owner, charterer, master or managing operator shall instruct each crew member, upon first being employed and prior to getting underway for the first time on a particular vessel and at least once every three months, as to the duties that the crew member is expected to perform in an emergency including, but not limited to, the emergency instructions listed on the emergency instruction placard required by § 185.510 of this part and, when applicable, the duties listed in the station bill required by § 185.514 of this part. (c) Crew training shall be logged or otherwise documented for review by the Coast Guard upon request. The training entry shall include the following information. (1) Date of the training; and (2) General description of the training topics. Vessel crew was unable to produce documentation of emergency training within three months.
Condition: Unknown
Action required: 10 - Deficiency Rectified
Due 21 September 2021
Resolved 7 September 2021
Resolution: Vessel crew logged drills occuring this date for CG inspection.
09 - Working and Living Conditions › 092 - Working Conditions › Guards - fencing around dangerous machinery parts
Issued 7 September 2021 Resolved
Machinery shall be installed in such a manner as to afford adequate protection against personnel injury and fire. The vessel’s port engine has a fuel leak and the engine’s exhaust installation wrap has some exposed/open areas. Correct leak and replace insulation prior to carrying passengers.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 21 September 2021
Resolved 8 September 2021
Resolution: Verified through operational test of engine that the fuel leak is secured and additional insulating wrap intalled.
11 - Life Saving Appliances › N/A - No Subsystem › On board training and instructions
Issued 7 September 2021 Resolved
The master shall conduct sufficient drills and give sufficient instructions to make sure that all crew members are familiar with their duties during emergencies that necessitate abandoning ship or the recovery of persons who have fallen overboard. Vessel’s crewman had only conducted man overboard drills verbally and was unprepared to respond to a man overboard drill.
Condition: Unknown
Action required: 10 - Deficiency Rectified
Due 21 September 2021
Resolved 7 September 2021
Resolution: Deckhand performed satisfactory man overboard drill on second attempt.
04 - Emergency Systems › N/A - No Subsystem › Emergency fire pump and its pipes
Issued 28 April 2021 Resolved
Piping for vital systems must be composed of ferrous materials. Marine Inspector observed in the tank space the most port side fix bilge pipe has a significant length of rubber hose installed beyond what is needed for flexibility. Make permanent repairs to the fixed bilge pipe with ferrous materials. 46 CFR 182.710 (c)(1)
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 5 May 2021
Resolution: Repairs to the piping were made by the owner.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Scuppers, inlets and discharges
Issued 28 April 2021 Resolved
Sea valves and strainers shall be of sufficient scope to determine that these items are in a satisfactory condition for the service intended. Marine Inspectors observed the starboard fire main uptake and generator uptake valves were difficult to operate. Make appropriate repairs. 46 CFR 176.25-5
Condition: Improper/Lack of Maintenance
Action required: 60 - Rectify deficiencies prior to movement
Resolved 5 May 2021
Resolution: Valves were lubricated and operate as designed.
01 - Certificates & Documentation › 011 - Ships Certificates › Cargo Ship Safety Radio (including exemption)
Issued 8 September 2020 Resolved
The provisions of Part III of Title III of the Communication Act require United States vessels which transport more than six passengers for hire while such vessels are being navigated on any tidewater within the jurisdiction of the United States adjacent or contiguous to the open sea, or in the open sea to carry a radiotelephone installation complying with this subpart. Vessel's Radio Safety Certificate expired in June of 2020. Vessel is restricted to a lakes, bays, and sounds route not more than 1000 feet from shore. 46 CFR 184.502 47 CFR 80.901
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Due 8 September 2020
Resolved 8 September 2020
Resolution: Vessel provided new FCC Safety Equipment Cert following radio installation inspection by FCC licensed tech.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 8 September 2020 Resolved
Means shall be to taken ensure the vessel is reasonably safe from fire caused by and/or originating in electrical equipment and reasonably safe from electrical shock of personnel. Several dead end wires were found in the E/R and one attached to the CO2 pressure switch. Additionally, the outlet on the aft E/R bulkhead is missing a cover. 46 CFR 183.01-05
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 22 September 2020
Resolved 14 September 2020
Resolution: Verified dead end wires in the engine room were capped, and verified outlet in the engine room had an installed cover.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Gauges, thermometers, etc
Issued 8 September 2020 Resolved
An ammeter shall be provided for measuring current of each generator. The ammeter is inoperable. 46 CFR 183.10-5(g)
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 22 September 2020
Resolved 14 September 2020
Resolution: Verified installation of ammeter.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 13 January 2020 Resolved
Fuel supply piping shall have a minimal pipe thickness of .035 inches. The high pressure fuel delivery line had developed a crack causing fuel to discharge into the vessel bilge. 46 CFR 182.20-40
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Resolved 13 January 2020
Resolution: A new high pressure fuel delivery pipe was installed.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 9 September 2019 Resolved
The part of the exhaust system between the point of cooling water injection and the engine manifold shall be water jacketed or adequately insulated. Insulating wrap aft of the turbo is loose or insufficiently wrapped on both engines. 46 CFR 182.15-20
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 23 September 2019
Resolved 8 September 2020
Resolution: Exhaust properly protected.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Gauges, thermometers, etc
Issued 9 September 2019 Resolved
A voltmeter and ammeter shall be provided for measuring voltage and current of each generator. The ammeter is inoperable. 46 CFR 183.10-5(g)
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 9 October 2019
Resolved 8 September 2020
Resolution: Deficiency re-issued as code 16c.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 9 September 2019 Resolved
Flexible hose installed in lengths of not more than 30 inches and subject to pressures of not more than 5 psi may be used if it meets subparagraphs A,B and C of this cite. Flexible fuel return hose (Parker 801-8) isi not USCG approved hose. 46 CFR 182.720 / 46 CFR 182.115(b)
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 23 September 2019
Resolved 8 September 2020
Resolution: COrrect hose installed.
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 9 September 2019 Resolved
Throughhull fittings shall be in satisfactory condition for the service intended. Port rudder post packing is leaking beyond a reasonable amount. 46 CFR 176.15-5
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 23 September 2019
Resolved 29 October 2019
Resolution: Verified rudder post was no longer exessively leaking.
02 - Structural Conditions › N/A - No Subsystem › Closing devices/watertight doors
Issued 11 September 2018 Resolved
At each inspection watertight closures in the hull shall be tested by operation. Both through hull valves for port and stbd engine's raw water cooling were seized in the open position. 46 CFR 176.25-5
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 11 September 2018
Resolved 20 September 2018
Resolution: Verified both raw water valves are operational.
11 - Life Saving Appliances › N/A - No Subsystem › Operational readiness of lifesaving appliances
Issued 11 September 2018 Resolved
At each inspection hydrostatic release units shall be checked for compliance with the servicing and usage requirements of 46 CFR 185.740. The vessel's hydrostatic release unit for the EPIRB is expired. Vessel is restricted from operating beyond three miles of shore until verified this items is corrected.
Condition: Invalid
Action required: 10 - Deficiency Rectified
Due 11 September 2018
Resolved 11 September 2018
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 11 September 2018 Resolved
Cylinders for the CO2 fixed fire extinguishing system shall be securely fastened. The bracket for the stbd CO2 bottle is unsecured. 46 CFR 181.20-30
Condition: Improper/Lack of Maintenance
Action required: 60 - Rectify deficiencies prior to movement
Due 11 September 2018
Resolved 20 September 2018
Resolution: Verified brackets for CO2 bottles is now secured.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 11 September 2018 Resolved
At each inspection electrical cable shall be examined for safe electrical condition. Exposed wires were found at the end of a conduit pipe used to support a flood light that is no longer installed. 46 CFR 176.25-15
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 11 September 2018
Resolved 20 September 2018
Resolution: Exposed wires are no longer exposed and presenting a safety hazard to passengers/crew.
01 - Certificates & Documentation › 013 - Documents › Signs, indications
Issued 11 September 2018 Resolved
Where passengers permitted on the upper deck is limited by stability criteria, the maximum number of passengers allowed must be indicated by a one inch in height durable marking. The marking shows 30 passengers are permitted while the stability letter addendum authorizes 25. 46 CFR 185.30-3
Condition: Improper Installation
Action required: 10 - Deficiency Rectified
Due 11 September 2018
Resolved 11 September 2018
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 11 September 2018 Resolved
The part of the main engine exhaust system between the point of cooling water injection and the engine manifold shall be water-jacketed or suitably insulated. Found exhaust wrap loose and/or missing small sections on both engines. 46 CFR 182.20-15
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 24 September 2018
Resolved 20 September 2018
Resolution: Verified the exhaust wrap is now properly installed.
Navigation › Piloting/Steering › Marine Charts
Issued 9 June 2017 Resolved
Provide up-to-date navigation charts for area of operations.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 23 June 2017
Resolved 19 June 2017
Resolution: Verified new charts are provided.
Engineering › Steering Gear System › Hydraulic Hose
Issued 9 June 2017 Resolved
Secure hydraulic steering lines where lying on main engine exhaust.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 23 June 2017
Resolved 19 June 2017
Resolution: Verified hydraulic lines are now secured properly.
Construction/Loadline › Structures › Transverse Bulkhead
Issued 9 June 2017 Resolved
Seal all open penetrations in underdeck bulkheads.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 23 June 2017
Resolved 19 June 2017
Resolution: Verified all open penetrations are now sealed.
Operations/Management › Pollution › Retention of Oily Mixture
Issued 9 June 2017 Resolved
Remove oil soaked absorbent pads and oily water from engine room bilges.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 23 June 2017
Resolved 19 June 2017
Resolution: Verified that oily pads and excess oily residue have been removed from engine room.
Stability › Watertight Integrity › General
Issued 9 June 2017 Resolved
Secure excessive water leak at both rudder post packings.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 16 June 2017
Resolved 19 June 2017
Resolution: Verified that the rudder post packings are properly tightened.
Communications › Alarms/Indicators › Bilge Alarm
Issued 9 June 2017 Resolved
Make high level bilge alarm system provide audible alarm.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 16 June 2017
Resolved 19 June 2017
Resolution: Verified the wheel house panel is providing an audible alarm.

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.