NEW HUSTLER

NEW HUSTLER is a 1968 passenger vessel (inspected). The Coast Guard has recorded 25 inspections since 2016, most recently in June 2025, along with 86 deficiencies and 2 operational controls.

Records from 2016 to 2025. Most recent: inspection, 10 June 2025.

Built
1968
Last inspected
10 June 2025
Documentation
Valid · documentation file of 10 August 2026
Controls
None recorded without a removal date

Identity

WDH 9966
Flag
UNITED STATES
Maury page id
psix-54939

Inspections, by type

…with no type recorded1
Years with a record 10 calendar years (2016–2025)
The 25 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 2016.

Documentation record

Registered dimensions (L × B × D)54.2 ft × 18.0 ft × 6.6 ft
Registered tonnagegross 49 / net 33
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderSEAWAY BOATS INC · LONG BEACH, CA, UNITED STATES · built 1968
Hull materialWood
PropulsionDiesel Reduction
Hull shapeUNSPECIFIED
Hull configurationUNSPECIFIED
Hailing portCHANNEL ISLANDS, CA
Trade endorsementsCoastwise, unrestricted, Registry
DocumentationValid · issued 7 March 2026 · expires 30 April 2027
Service, as the file records itPassenger (Inspected)
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it49 - Regulatory (Subpart C or D), Gross Ton
33 - Regulatory (Subpart C or D), Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 August 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.

One vessel history report for this hull — every record on this page in one dated, citable document — $300, on request.

Inspection history · 25

10 June 2025 Annual Inspection · Deficiency Check
Physical examination · Marine Safety Detachment Santa Barbara · USCG Southwest District (CGD-SW) · Activity 8156026
30 April 2025 Hull Examination
Physical examination · Marine Safety Detachment Santa Barbara · USCG Southwest District (CGD-SW) · Activity 8126325
13 June 2024 Administrative Inspection · Deficiency Check
Physical examination · Marine Safety Detachment Santa Barbara · USCG Southwest District (CGD-SW) · Activity 7934025
14 May 2024 Annual Inspection · Administrative Inspection
Physical examination · Marine Safety Detachment Santa Barbara · USCG Southwest District (CGD-SW) · Activity 7911367
20 December 2023 In-Service Inspection · Administrative Inspection
Physical examination · Marine Safety Detachment Santa Barbara · USCG Southwest District (CGD-SW) · Activity 7841012
1 June 2023 Examination of Repairs · Deficiency Check · Annual Inspection
Physical examination · Marine Safety Detachment Santa Barbara · USCG Southwest District (CGD-SW) · Activity 7696814
1 March 2023 Deficiency Check · Hull Examination
Physical examination · Marine Safety Detachment Santa Barbara · USCG Southwest District (CGD-SW) · Activity 7642888
23 December 2022 Plan Review "T" Boat
Administrative · Marine Safety Detachment Santa Barbara · USCG Southwest District (CGD-SW) · Activity 7612587
19 October 2022 In-Service Inspection
Physical examination · Marine Safety Detachment Santa Barbara · USCG Southwest District (CGD-SW) · Activity 7577720
16 March 2022 COI Inspection
Physical examination · Marine Safety Detachment Santa Barbara · USCG Southwest District (CGD-SW) · Activity 7394441
16 October 2021 In-Service Inspection
Physical examination · Marine Safety Detachment Santa Barbara · USCG Southwest District (CGD-SW) · Activity 7331020
19 September 2021 In-Service Inspection
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 7314825
18 September 2021 Type not recorded
No type recorded · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 7316491
27 May 2021 Annual Inspection
Physical examination · Marine Safety Detachment Santa Barbara · USCG Southwest District (CGD-SW) · Activity 7202438
23 February 2021 Hull Examination
Physical examination · Marine Safety Detachment Santa Barbara · USCG Southwest District (CGD-SW) · Activity 7142674
11 June 2020 Deficiency Check · Annual Inspection
Physical examination · Marine Safety Detachment Santa Barbara · USCG Southwest District (CGD-SW) · Activity 6971243
22 October 2019 Deficiency Check · In-Service Inspection
Physical examination · Marine Safety Detachment Santa Barbara · USCG Southwest District (CGD-SW) · Activity 6828430
2 July 2019 Annual Inspection · Deficiency Check
Physical examination · Marine Safety Detachment Santa Barbara · USCG Southwest District (CGD-SW) · Activity 6732328
28 January 2019 Hull Examination · Deficiency Check
Physical examination · Marine Safety Detachment Santa Barbara · USCG Southwest District (CGD-SW) · Activity 6608001
14 June 2018 Annual Inspection
Physical examination · Marine Safety Detachment Santa Barbara · USCG Southwest District (CGD-SW) · Activity 6438018
21 July 2017 Administrative Inspection
Administrative · Marine Safety Detachment Santa Barbara · USCG Southwest District (CGD-SW) · Activity 6262626
27 February 2017 Deficiency Check · COI Inspection · DAPI Audit · Administrative Inspection
Physical examination · Marine Safety Detachment Santa Barbara · USCG Southwest District (CGD-SW) · Activity 6101969
6 January 2017 Plan Review "T" Boat · Hull Examination · Deficiency Check
Physical examination · Marine Safety Detachment Santa Barbara · USCG Southwest District (CGD-SW) · Activity 6070788
10 May 2016 Annual Inspection · Deficiency Check
Physical examination · Marine Safety Detachment Santa Barbara · USCG Southwest District (CGD-SW) · Activity 5872988
25 April 2016 Hull Examination
Physical examination · Marine Safety Detachment Santa Barbara · USCG Southwest District (CGD-SW) · Activity 5864225

Deficiency record · 86

05 - Radio Communications › N/A - No Subsystem › Other (radio communication)
Issued 10 June 2025 Resolved
[withheld — contains personal information; the deficiency system, dates, and resolution status are shown above]
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 24 June 2025
Resolved 26 June 2025
Resolution: FCC Station License issued on 6/25/2025 valid until 6/25/2035
14 - Pollution Prevention › 145 - MARPOL Annex V › Garbage
Issued 10 June 2025 Resolved
The master or person in charge of a ship to which this section applies shall ensure that the ship is not operated unless a garbage management plan meeting paragraph (b) of this section is on the ship and that each person handling garbage follows the plan.(b) Each garbage management plan under paragraph (a) of this section must be in writing and—(1) Provide for the discharge of garbage by means that meet Annex V of MARPOL, the Act, and §§ 151.51 through 151.77;(2) Describe procedures for minimizing, collecting, processing, storing, and discharging garbage; and(3) Designate the person who is in charge of carrying out the plan. Provide and post garbage management plan.
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Resolved 10 June 2025
Resolution: Vessel proivded plan.
10 - Safety of Navigation › N/A - No Subsystem › Other (navigation)
Issued 10 June 2025 Resolved
The operator of each self-propelled vessel 12 meters or more in length shall carry, on board and maintain for ready reference, a copy of these Rules. Vessel missing inland navigation rules ready reference. Provide a ready reference of the inland navigation rules to the attending marine inspector.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 24 June 2025
Resolved 26 June 2025
05 - Radio Communications › N/A - No Subsystem › Maintenance/duplication of equipment
Issued 14 May 2024 Resolved
A vessel must comply with the applicable requirements for any radio and Electronic Position Indicating Radiobeacon (EPIRB) installations, including the requirements for a station license and installation certificates to be issued by the Federal Communications Commission, as set forth in 47 CFR part 80. Vessel's FCC Safety Radiotelephony Certificate expired 22May20. Provide updated Safety Radiotelephony Certificate to the attending marine inspector.
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Due 28 May 2024
Resolved 20 June 2024
Resolution: Vessel provided valid radio certificate.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 14 May 2024 Resolved
A vessel not required to have a power driven fire pump by § 181.300 must have at least three 9.5 liter (2 1/2 gallon) buckets, with an attached lanyard satisfactory to the cognizant OCMI, placed so as to be easily available during an emergency. The words “FIRE BUCKET” must be stenciled in a contrasting color on each bucket. Vessel's fire buckets were only 2 gallon capacity. Provide fire (3) fire buckets of 2.5 gallon capacity to the attending marine inspector.
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 14 June 2024
Resolved 21 June 2024
Resolution: Vessel replaced with 2.5 gallon capacity.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 14 May 2024 Resolved
Each life jacket must be marked with Type I retroreflective material approved in 46 CFR 164.018 or other standard specified by the Commandant. The arrangement of the retroreflective material applied after March 11, 1996, must be as specified by IMO Resolution A.658(16) (incorporated by reference; see 46 CFR 175.600). (3) child life jackets retroflective tape were faded and peeling. Replace the (3) child life jackets retroflective tape.
Condition: Damaged By Earlier Event
Action required: 50 - Rectify deficiencies w/in 30 days
Due 14 June 2024
Resolved 16 July 2024
Resolution: Vessel replaced (3) child life jacket retroflective tapes.
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 14 May 2024 Resolved
Waste receptacles. Unless other means are provided to ensure that a potential waste receptacle fire would be limited to the receptacle, waste receptacles must be constructed of noncombustible materials with no openings in the sides or bottom. Vessel had combustible plastic waste receptacles onboard the vessel. Replace all combustible waste receptacles with non-combustible type.
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 14 June 2024
Resolved 14 August 2024
Resolution: Waste receptacle replaced with metal type.
09 - Working and Living Conditions › 092 - Working Conditions › Obstruction/slipping, etc.
Issued 14 May 2024 Resolved
All passenger accommodations must be arranged and equipped to provide for the safety of the passengers in consideration of the route, modes of operation, and speed of the vessel. Port passenger accommodation stairwell top step was loose and missing adequate support. Provide repair and proper support to the stairwell's top step to the attending marine inspector.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 14 June 2024
Resolved 14 August 2024
Resolution: Step support was replaced.
01 - Certificates & Documentation › 013 - Documents › Log-books/compulsory entries
Issued 1 June 2023 Resolved
Fire, abandon ship and man overboard drills and training shall be logged or otherwise documented for review by the Coast Guard upon request. The drill entry shall include the following information: (1) Date of the drill and training; and (2) General description of the drill scenario and training topics. Logs recording drills, training and inspection and testing of lifesavign and firefighting equipment were not available during inspection. Provide logs showing completion of drills, trianign and inspections to attending marine inspector.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 15 June 2023
Resolved 8 June 2023
Resolution: Vessel provided logs.
18 - Maritime Labour Convention (Not Applicable to PSC Exams conducted in the U.S.) › N/A - No Subsystem › Other (Conditions of employment)
Issued 1 June 2023 Resolved
The marine employer must have a sufficient number of alcohol testing devices readily accessible on board the vessel to determine the presence of alcohol in the system of each individual who was directly involved in the SMI. On board alcohol swabs were expired. Provide current alcohol testing devices.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 15 June 2023
Resolved 8 June 2023
Resolution: Vessel provided current alcohol swabs.
10 - Safety of Navigation › N/A - No Subsystem › Voyage or passage plan
Issued 1 June 2023 Resolved
On vessels described by 46 CFR 175.110(d) of this chapter, a passenger safety bill must be posted by the master in each cabin or stateroom, and in passenger accommodation spaces. (b) Each passenger safety bill required by this section must list: (1) The embarkation station and the number and location of the survival craft to which each passenger is assigned, if applicable; (2) The fire and emergency signal and the abandon ship signal; (3) Essential action that must be taken in an emergency; and (4) If immersion suits are provided for passengers, the location of the suits and illustrated instructions on the method of donning the suits. Vessel did not have posted passenger safety bills. Provide passenger safety bills in each bunk room.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 15 June 2023
Resolved 8 June 2023
Resolution: Vessel drafted passenger safety bills.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 1 June 2023 Resolved
A vessel not required to have a power driven fire pump by § 181.300 must have at least three 9.5 liter (21/2 gallon) buckets, with an attached lanyard satisfactory to the cognizant OCMI, placed so as to be easily available during an emergency. The words “FIRE BUCKET” must be stenciled in a contrasting color on each bucket. Two of the three provided fire buckets did not have attached lanyards. Provide three acceptable fire buckets.
Condition: Damaged By Earlier Event
Action required: 16 - Rectify deficiencies w/in 14 days
Due 15 June 2023
Resolved 8 June 2023
Resolution: Vessel repaired lanyards.
07 - Fire Safety › N/A - No Subsystem › Fixed fire extinguishing installation
Issued 1 June 2023 Resolved
A vessel on which a pre-engineered fixed gas fire extinguishing system is installed must have the following equipment at the operating station: (3) A means to reset devices used to automatically shut down ventilation systems and engines as required by paragraph (a)(3) of this section. The Fire Boy engine shut down override was not functioning. Repair or replace and demonstrate proper operation.
Condition: Damaged By Earlier Event
Action required: 16 - Rectify deficiencies w/in 14 days
Due 15 June 2023
Resolved 20 June 2023
Resolution: Vessel re-wired override and demonstrated proper operation.
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 1 June 2023 Resolved
An internal structural examination conducted in compliance with § 176.600 may be conducted while the vessel is afloat or out of the water and consists of a complete examination of the vessel's main strength members, including the major internal framing, the hull plating and planking, voids, and ballast, cargo, and fuel oil tanks. A longitudinal frame and a hanging knee were found delaminating and separating from the hull on the starboard side of the vessel in the lazarette. Provide repair proposal to attending marine inspector.
Condition: Damaged By Earlier Event
Action required: 16 - Rectify deficiencies w/in 14 days
Due 15 June 2023
Resolved 7 July 2023
Resolution: Visual and material inspection identified solid wood unaffected by rot. Hanging knee determined to be part of previous shelving and permanently removed from the vessel.
07 - Fire Safety › N/A - No Subsystem › Maintenance of Fire protection systems
Issued 19 October 2022 Resolved
The owner, managing operator, or a qualified servicing facility as applicable must conduct the following inspections and tests: For fixed-gas fire extinguishing systems, the inspections and tests required by Table 176.810(b) of this section, in addition to the tests required by 46 CFR 147.60 and 147.65. The owner or managing operator must provide satisfactory evidence of the required servicing to the marine inspector. If any of the equipment or records have not been properly maintained, a qualified servicing facility may be required to perform the required inspections, maintenance procedures, and hydrostatic pressure tests. No record was available for the annual inspection of the fixed pre-engineered firefighing system installed in the engine room. Provide documentation showing completion of annual inspection and servicing.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 2 November 2022
Resolved 21 October 2022
Resolution: Vessel provided record showing annual servicing of fixed ssytem.
07 - Fire Safety › N/A - No Subsystem › Fire patrol
Issued 19 October 2022 Resolved
Vessels described by 46 CFR 175.110(d) must submit plans to the cognizant OCMI, in accordance with 46 CFR 176.700, for the installation and use of monitoring device to ensure the wakefulness of the watchmen required in paragraph (a) of this section. The Coast Guard will work with the vessel operators to determine a reasonable implementation schedule once the plans are accepted. The monitoring device(s) must: (1) Ensure the wakefulness of the crew in the event that the watchman required in paragraph (a) of this section is unresponsive; (2) Remain operable during the nighttime watch; and (3) Be arranged to ensure proper coverage of the passenger accommodation spaces, common areas, and spaces with potential fire hazards. Plans have not been submitted to the cognizant [name withheld] plans to include electrical load analysis and bill of materials.
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 18 November 2022
Resolved 20 November 2022
Resolution: Vessel submitted proposal to use the Blue Guard system.
04 - Emergency Systems › N/A - No Subsystem › Fire drills
Issued 19 October 2022 Resolved
The owner, charterer, master or managing operator shall instruct each crew member, upon first being employed and prior to getting underway for the first time on a particular vessel and at least once every three months, as to the duties that the crew member is expected to perform in an emergency including, but not limited to, the emergency instructions listed on the emergency instruction placard required by § 185.510 of this part and, when applicable, the duties listed in the station bill required by § 185.514 of this part. Training must include the items listed in 46 CFR 185.420 (b). in addition, Emergency egress training for each member of the crew, to occur for all members of the crew - (i) At least monthly while such members are employed on board the vessels; and (ii) Each time a crew member joins the crew of such vessel. Crew training shall be logged or otherwise documented for review by the Coast Guard upon request. The training entry shall include the following information. (1) Date of the training; and (2) General description of the training topics.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 18 November 2022
Resolved 13 December 2022
Resolution: Vessel provided records showing completion of training and drills.
01 - Certificates & Documentation › 012 - Crew Certificates › Medical certificate
Issued 19 October 2022 Resolved
A person may not employ or engage an individual in a position required to hold an MMC unless that individual maintains a current medical certificate. Vessel's licensed Master did not have medical certificate available for inspection. Provide proof of medical certificate or correspondence from NMC attesting to valid medical certificate.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 18 November 2022
Resolved 26 November 2022
Resolution: Operator provided medical certificate.
05 - Radio Communications › N/A - No Subsystem › VHF radio installation
Issued 16 March 2022 Resolved
[withheld — contains personal information; the deficiency system, dates, and resolution status are shown above]
Condition: Placed in Improper Service
Action required: 50 - Rectify deficiencies w/in 30 days
Due 15 April 2022
Resolved 11 May 2022
Resolution: Vessel provided FCC operators permit for vessel master.
04 - Emergency Systems › N/A - No Subsystem › Muster list
Issued 16 March 2022 Resolved
Except when in the judgment of the cognizant OCMI the operation of a vessel does not present one of the hazards listed, the emergency instruction placard should contain at least the applicable portions of the “Emergency Instructions” listed in § 185.512. The emergency instructions must be designed to address the particular equipment, arrangement, and operation of each individual vessel. Vessel's emergency instructions were not vessel specific. Provide vessel specific emergency instructions.
Condition: Placed in Improper Service
Action required: 50 - Rectify deficiencies w/in 30 days
Due 15 April 2022
Resolved 24 March 2022
Resolution: Vessel provided revised emergency instructions.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 16 March 2022 Resolved
A vessel not required to have a power driven fire pump by § 181.300 must have at least three 9.5 liter (21/2 gallon) buckets, with an attached lanyard satisfactory to the cognizant OCMI, placed so as to be easily available during an emergency. The words “FIRE BUCKET” must be stenciled in a contrasting color on each bucket. Vessel was missing one bucket and existing buckets require replacement lanyards. Provide 3 properly arranged fire buckets.
Condition: Damaged By Earlier Event
Action required: 50 - Rectify deficiencies w/in 30 days
Due 15 April 2022
Resolved 23 March 2022
Resolution: Vessel provided fire buckets.
01 - Certificates & Documentation › 013 - Documents › Log-books/compulsory entries
Issued 16 October 2021 Resolved
Abandon ship and man overboard drills and training shall be logged or otherwise documented for review by the Coast Guard upon request. The drill entry shall include the following information: (1) Date of the drill and training; and (2) General description of the drill scenario and training topics. Records were not available for abandon ship drills. Upon questioning, master and crew stated that they held table-top abandon ship training but did not log it. Conduct abandon ship drill and associated log entry.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 14 November 2021
Resolved 17 November 2021
Resolution: Vessel completed abandon ship drill and logged completion.
01 - Certificates & Documentation › 013 - Documents › Log-books/compulsory entries
Issued 16 October 2021 Resolved
The master of the vessel shall ensure that: (a) Each EPIRB, other than an EPIRB in an inflatable liferaft, must be tested monthly, using the integrated test circuit and output indicator, to determine that it is operative; (b) The EPIRB's battery is replaced after it is used, or before the date required by FCC regulations in 47 CFR part 80, whichever comes sooner; and (c) The EPIRB test required by paragraph (a) shall be logged or otherwise documented, as applicable. Log of EPIRB testing was not available. Master and crew attested that EPIRB was tested monthly along with other equipment inspections. Test EPIRB and provide log entry.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 14 November 2021
Resolved 17 November 2021
Resolution: Vessel provided completed EPIRB check documentation.
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 13 October 2021 Resolved
Electrical equipment on a vessel must be installed and maintained to protect passengers, crew, other persons, and the vessel from electrical hazards, including fire, caused by or originating in electrical equipment, and electrical shock. The pilot house was found to have ungrounded electrical outlet.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 12 November 2021
Resolved 15 October 2021
Resolution: Vessel replaced outlet and retested for ground.
04 - Emergency Systems › N/A - No Subsystem › Means of communication between safety centre and other control stations
Issued 27 May 2021 Resolved
Public address system not audible in passenger bunk rooms. Provide speakers in all passenger accessible spaces.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 10 June 2021
Resolved 15 June 2021
Resolution: Vessel installed speakers in both bunk rooms.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 11 June 2020 Resolved
Provide a letter for consideration on galley grease hood extraction system.
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 14 August 2020
Resolution: Letter received and scanned into MISLE.
01 - Certificates & Documentation › 011 - Ships Certificates › Other (certificates)
Issued 11 June 2020 Resolved
Provide a current FCC safety certificate.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 23 July 2020
Resolution: Received updated certificate.
07 - Fire Safety › N/A - No Subsystem › Maintenance of Fire protection systems
Issued 11 June 2020 Resolved
Fire equipment service expires in July 2020, have equipment serviced.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 23 July 2020
Resolution: Equipment serviced.
11 - Life Saving Appliances › N/A - No Subsystem › Maintenance and inspections
Issued 11 June 2020 Resolved
Life saving equipment servicing expires in July 2020, Have equipment serviced.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 23 July 2020
Resolution: Equipment serviced.
01 - Certificates & Documentation › 011 - Ships Certificates › Other (certificates)
Issued 11 June 2020 Resolved
Provide MIS report.
Action required: 10 - Deficiency Rectified
Resolved 11 June 2020
Resolution: Report provided.
07 - Fire Safety › N/A - No Subsystem › Means of escape
Issued 22 October 2019 Resolved
Provide unobstructed escape route from both bunk rooms. Current escape hatches are openable but partially obstructed by freezer and and ladder.
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 27 March 2020
Resolution: Received evidence that the escape route are unobstructed.
09 - Working and Living Conditions › 091 - Living Conditions › Furnishings
Issued 22 October 2019 Resolved
Provide flame retardant mattress covering with attestation from master or provide mattresses meeting 16CFR1632.
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 27 March 2020
Resolution: Received proof that the mattresses are now compliant.
15 - Safety Management Systems (ISM) › N/A - No Subsystem › Company responsibility and authority
Issued 22 October 2019 Resolved
Provide voyage plans ashore for overnight trips.
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 5 December 2019
Resolution: Plan provided.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 22 October 2019 Resolved
Provide metallic wire hangers at 24" intervals in forepeak.
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 5 December 2019
Resolution: Hangers installed.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 22 October 2019 Resolved
Remove extension cord from freezer installation.
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 5 December 2019
Resolution: Cord removed.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 22 October 2019 Resolved
Forward storeroom breaker panel breakers showed saltwater corrosion, Clean or replace breakers.
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 5 December 2019
Resolution: Breakers and panel cleaned.
04 - Emergency Systems › N/A - No Subsystem › Emergency, lighting, batteries and switches
Issued 22 October 2019 Resolved
Properly splice wiring for emergency lighting in starboard bunkroom.
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 5 December 2019
Resolution: Light properly spliced.
11 - Life Saving Appliances › N/A - No Subsystem › Inflatable liferafts
Issued 2 July 2019 Resolved
Passenger count reduced to 21 passengers, 4 crew, 25 total persons on board for Oceans Route due to primary lifesaving capacity.
Action required: 705 - Other - as specified
Due 2 July 2019
Resolved 30 July 2019
Resolution: Vessel completed servicing of primary lifesaving.
11 - Life Saving Appliances › N/A - No Subsystem › Inflatable liferafts
Issued 2 July 2019 Resolved
Passenger count reduced to 40 passengers, 4 crew, and 44 total persons on board for Coastwise route due to primary lifesaving capacity.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 16 July 2019
Resolved 30 July 2019
Resolution: Amended COI to reflect corrected coastwise passenger count.
10 - Safety of Navigation › N/A - No Subsystem › Lights, shapes, sound-signals
Issued 2 July 2019 Resolved
Replace port side running light lens.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 1 August 2019
Resolved 30 July 2019
Resolution: Vessel replaced lens.
09 - Working and Living Conditions › 092 - Working Conditions › Lighting (Working spaces)
Issued 2 July 2019 Resolved
Remove liquid and re-mount light in starboard head.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 1 August 2019
Resolved 30 July 2019
Resolution: Vessel replaced lighting fixture.
09 - Working and Living Conditions › 091 - Living Conditions › Medical Equipment
Issued 2 July 2019 Resolved
Provide complete and current first aid kit.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 2 July 2019
Resolved 30 July 2019
Resolution: Vessel provided replacement first aid items.
05 - Radio Communications › N/A - No Subsystem › VHF radio installation
Issued 2 July 2019 Resolved
Provide MMSI programmed in to DSC VHF radio.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 2 July 2019
Resolved 30 July 2019
Resolution: Vessel demonstrated that MMSI was properly programmed.
11 - Life Saving Appliances › N/A - No Subsystem › Inflatable liferafts
Issued 2 July 2019 Resolved
Provide primary lifesaving. IBA found beyond servicing date.
Action required: 10 - Deficiency Rectified
Due 2 July 2019
Resolved 2 July 2019
Resolution: Vessel provided a temporary IBA while awaiting servicing of regular IBA.
Fire Fighting › Means of Escape › Escape Route Signs
Issued 14 June 2018 Resolved
Stencil escape hatches from berthing on topside.
Condition: Invalid
Action required: 50 - Rectify deficiencies w/in 30 days
Due 14 June 2018
Resolved 25 June 2018
Resolution: Escape hatch stenciled.
Pollution Prevention/Response › Prevention Equipment › Sewage System Valve
Issued 21 July 2017 Resolved
Ensure sewage overboard discharge valves are functional, accessible, and can be secured with a lock when required. Ensure Master is aware of when/where valves must be secured.
Action required: 705 - Other - as specified
Due 21 August 2017
Resolved 22 September 2017
Pollution Prevention/Response › Prevention Equipment › Sewage System Piping
Issued 21 July 2017 Resolved
Ensure marine toilet can be flushed on demand and is not configured to allow constant flow of flush water.
Condition: Placed in Improper Service
Action required: 705 - Other - as specified
Due 21 August 2017
Resolved 22 September 2017
Engineering › Steering Gear System › Hydraulic Hose
Issued 17 March 2017 Resolved
Repair/Adjust weeping hydraulic line in E/R.
Action required: 705 - Other - as specified
Due 17 May 2017
Resolved 10 May 2017
Resolution: Hydraulic line replaced.
Engineering › Diesel Engine (propulsion-reduction gear) › Exhaust Manifold
Issued 17 March 2017 Resolved
Provide proper support for exhaust pipes in laz.
Action required: 705 - Other - as specified
Due 17 May 2017
Resolved 10 May 2017
Resolution: Exhaust pipes properly supported.
Deck/Cargo › Holds/Tanks › Hatch
Issued 17 March 2017 Resolved
Re-stencil emergency escape hatch in port berthing.
Action required: 705 - Other - as specified
Due 17 May 2017
Resolved 10 May 2017
Resolution: Emergency escape hatch properly marked.
Pollution Prevention/Response › Prevention Equipment › Sewage System Piping
Issued 17 March 2017 Resolved
Replace schedule 40 PVC elbow in sewage discharge pipe with schedule 80.
Action required: 705 - Other - as specified
Due 17 May 2017
Resolved 10 May 2017
Resolution: Schedule 80 PVC installed.
Fire Fighting › Fixed Fire Detection System › Smoke Detectors
Issued 17 March 2017 Resolved
Replace smoke detectors with UL-417 unit in stbd berthing.
Action required: 705 - Other - as specified
Due 17 May 2017
Resolved 10 May 2017
Resolution: Smoke detector replaced.
Operations/Management › Drug and Alcohol Testing › MIS Submission
Issued 17 March 2017 Resolved
Provide MIS report.
Action required: 705 - Other - as specified
Due 17 April 2017
Resolved 17 March 2017
Resolution: MIS report provided.
Documentation › Markings/Placards › Lifejacket Placard
Issued 17 March 2017 Resolved
Post life jacket donning placard and emergency instructions list.
Action required: 705 - Other - as specified
Due 17 May 2017
Resolved 10 May 2017
Resolution: Life jacket placard and emergency instructions posted.
Fire Fighting › Grease Extraction Hood › General
Issued 17 March 2017 Resolved
Clean galley grease trap.
Action required: 705 - Other - as specified
Due 17 May 2017
Resolved 10 May 2017
Resolution: Grease trap cleaned.
Construction/Loadline › Structures › Superstructure
Issued 17 March 2017 Resolved
Replace port galley window.
Action required: 705 - Other - as specified
Due 17 May 2017
Resolved 10 May 2017
Resolution: Window replaced.
Documentation › Certificates/Documents › Certificate of Inspection
Issued 17 March 2017 Resolved
Post all pages of COI.
Action required: 705 - Other - as specified
Due 17 May 2017
Resolved 10 May 2017
Resolution: COI pages posted.
Fire Fighting › Remote Fuel Shutoff › General
Issued 17 March 2017 Resolved
Mark fuel shut-off valves.
Action required: 705 - Other - as specified
Due 17 May 2017
Resolved 10 May 2017
Resolution: Fuel shut-off valves marked.
Deck/Cargo › Holds/Tanks › Hatch Cover
Issued 17 March 2017 Resolved
Repair/replace E/R hatch.
Action required: 705 - Other - as specified
Due 17 May 2017
Resolved 10 May 2017
Resolution: Hatch repaired.
Documentation › Certificates/Documents › Certificate of Inspection
Issued 27 February 2017 Resolved
Vessel current COI expires 27FEB17. Vessel restricted from carrying passengers until COI inspection is completed and TCOI is issued.
Action required: 705 - Other - as specified
Due 27 February 2017
Resolved 17 March 2017
Resolution: COI inspection completed; issued TCOI.
Communications › Radio Communications › VHF Radiotelephone
Issued 27 February 2017 Resolved
Provide class D VHF-DSC radio and enter MMSI number.
Action required: 705 - Other - as specified
Due 17 May 2017
Resolved 10 May 2017
Resolution: Class D VHF-DSC radio installed.
Operations/Management › Bilge/Bilge System Management › Control of Excess Water
Issued 6 January 2017 Resolved
Dry bilges IVO both water tanks and put water into tanks to verify no leaks.
Action required: 705 - Other - as specified
Due 6 February 2017
Resolved 17 March 2017
Resolution: No leaks in water tanks.
Deck/Cargo › Holds/Tanks › Hatch
Issued 6 January 2017 Resolved
Provide inspection port in stbd lower outboard bunk forward and in port lower outboard bunk aft.
Action required: 705 - Other - as specified
Due 6 February 2017
Resolved 17 March 2017
Resolution: Inspection ports provided.
Construction/Loadline › Hull › Longitudinal Frame
Issued 6 January 2017 Resolved
E/R hull inspection pending removal of machinery for repower.
Action required: 705 - Other - as specified
Due 6 February 2017
Resolved 19 January 2017
Resolution: E/R hull and longitudinal frames inspection sat.
Accommodation/Occupational Safety › Occupational Safety › Tripping/Falling Hazard
Issued 6 January 2017 Resolved
Repair broken ladder into laz.
Action required: 705 - Other - as specified
Due 6 February 2017
Resolved 14 February 2017
Resolution: Ladder repaired.
Electrical › Electrical Distribution System (service) › Grounding Conductor
Issued 6 January 2017 Resolved
Reconnect loose bonding wire in forward and port aft of laz.
Action required: 705 - Other - as specified
Due 6 February 2017
Resolved 14 February 2017
Resolution: Bonding wire reconnected.
Construction/Loadline › Hull › Side Shell
Issued 6 January 2017 Resolved
Repair delamination of FRP overlay on side shell of port bow.
Action required: 705 - Other - as specified
Due 6 February 2017
Resolved 14 February 2017
Resolution: FRP overlay repaired.
Operations/Management › Vessel Activity › Underway
Issued 6 January 2017 Resolved
Complete post drydock checkride.
Action required: 705 - Other - as specified
Due 6 February 2017
Resolved 17 March 2017
Resolution: Post drydock checkride completed.
Engineering › Steering Gear System › Fastener
Issued 6 January 2017 Resolved
Remove paint and clean mounting bolts for P/S rudder posts for further inspection.
Action required: 705 - Other - as specified
Due 6 February 2017
Resolved 14 February 2017
Resolution: Mounting bolts re-inspection sat.
Construction/Loadline › Hull › Side Shell
Issued 10 May 2016 Resolved
Make proper repairs to plywood hull IWO stbd chine fwd berthing due to water ingress, prior to carrying passengers.
Action required: 701 - Prior to carriage of passengers/cargo
Due 10 May 2016
Resolved 17 May 2016
Resolution: Repairs and sea-trial completed.
Accommodation/Occupational Safety › Occupational Safety › Hand Grab
Issued 10 May 2016 Resolved
Provide ladder to access IBA.
Action required: 705 - Other - as specified
Due 10 June 2016
Resolved 17 June 2016
Accommodation/Occupational Safety › Sleeping Accommodations › Berth
Issued 10 May 2016 Resolved
Repair flooring in P/S berthing aft and fwd.
Action required: 705 - Other - as specified
Due 10 June 2016
Resolved 17 May 2016
Resolution: Flooring repaired.
Accommodation/Occupational Safety › Occupational Safety › Portable Electric Equipment/Appliances
Issued 10 May 2016 Resolved
Secure freezer and water pump compartment forward of berthing space.
Action required: 705 - Other - as specified
Due 10 June 2016
Resolved 17 June 2016
Communications › Radio Communications › EPIRB
Issued 10 May 2016 Resolved
Provide current NOAA registration for EPIRB.
Action required: 705 - Other - as specified
Due 10 June 2016
Resolved 17 June 2016
Fire Fighting › Fixed Gas Fire Extinguishing System › Operating Controls
Issued 10 May 2016 Resolved
Reconnect genset to Fireboy shutdown prior to carrying passengers.
Action required: 701 - Prior to carriage of passengers/cargo
Due 10 May 2016
Resolved 17 May 2016
Resolution: Genset shutdown with fireboy, all sat.
Engineering › Sea-water System (primary cooling) › Pump
Issued 10 May 2016 Resolved
Repair water leak at genset water pump.
Action required: 705 - Other - as specified
Due 10 June 2016
Resolved 17 May 2016
Resolution: Water leak repaired.
Fire Fighting › Portable Dry Chemical Fire Extinguisher › Mounting Bracket
Issued 10 May 2016 Resolved
Properly mount all fire extinguishers.
Action required: 705 - Other - as specified
Due 10 June 2016
Resolved 17 May 2016
Resolution: All extinguishers mounted.
Pollution Prevention/Response › Prevention Equipment › Sewage System Piping
Issued 10 May 2016 Resolved
Repair hose leak to thru-hull on MSD piping.
Action required: 705 - Other - as specified
Due 10 June 2016
Resolved 17 May 2016
Resolution: Hose replaced.
Electrical › Electrical Distribution System (service) › Wiring
Issued 10 May 2016 Resolved
Hard wire water pump in fwd berthing compartment.
Action required: 705 - Other - as specified
Due 10 June 2016
Resolved 17 May 2016
Resolution: Pump hard wired to panel.
Stability › Weathertight Integrity › General
Issued 10 May 2016 Resolved
Make covers to P/S berthing weathertight.
Action required: 705 - Other - as specified
Due 10 June 2016
Resolved 17 June 2016
Electrical › Electrical Distribution System (service) › Panelboard
Issued 10 May 2016 Resolved
Label E/R and fwd berthing compartment electrical panels.
Action required: 705 - Other - as specified
Due 10 June 2016
Resolved 17 May 2016
Resolution: Panels properly marked.
Engineering › Sea-water System (primary cooling) › Piping
Issued 10 May 2016 Resolved
Replace stbd MDE cooling hose.
Action required: 705 - Other - as specified
Due 10 June 2016
Resolved 17 May 2016
Resolution: Hose replaced.
Fire Fighting › Ventilation Systems › Ventilation Fire Dampers
Issued 10 May 2016 Resolved
Provide damper for fwd E/R ventilation.
Action required: 705 - Other - as specified
Due 10 June 2016
Resolved 17 June 2016
Construction/Loadline › Structures › Transverse Bulkhead
Issued 25 April 2016 Resolved
Re-cleat aft E/R bulkhead due to wasted fasteners.
Action required: 705 - Other - as specified
Due 10 May 2016
Resolved 10 May 2016
Resolution: Aft E/R bulkhead re-cleated.
Construction/Loadline › Structures › Transverse Bulkhead
Issued 25 April 2016 Resolved
Make aft E/R bulkhead gas tight.
Action required: 705 - Other - as specified
Due 10 May 2016
Resolved 10 May 2016
Resolution: Aft E/R bulkhead is gas tight.
Construction/Loadline › Penetrations › Valve Flange
Issued 25 April 2016 Resolved
Provide metallic cap for unused thru-hull in E/R.
Due 10 May 2016
Resolved 10 May 2016
Resolution: Cap provided.

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.