Records from 2017 to 2026. Most recent: inspection, 31 July 2026.
Inspection history · 17
31 July 2026
Administrative Inspection · COI Inspection · Deficiency Check
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 8451271
3 April 2026
Internal Structural Exam · Drydock Exam
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 8341485
26 September 2025
Annual Inspection
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 8242072
20 September 2024
Annual Inspection
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 7990249
28 March 2024
Drydock Exam · Internal Structural Exam
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 7875130
1 September 2023
Annual Inspection
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 7771381
15 September 2022
Annual Inspection · Deficiency Check
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 7546058
29 March 2022
Drydock Exam · Internal Structural Exam · Deficiency Check
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 7406024
13 July 2021
Deficiency Check · COI Inspection
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 7238404
31 August 2020
Annual Inspection
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 7043388
26 March 2020
Internal Structural Exam · Drydock Exam
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 6927494
1 October 2019
Annual Inspection · DAPI Audit
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 6814856
5 June 2019
Examination of Repairs
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 6704897
4 October 2018
DAPI Audit · Annual Inspection
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 6549143
24 July 2018
Hull Examination · Internal Structural Exam · Drydock Exam
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 6477622
10 July 2018
Administrative Inspection
Administrative · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 6474572
31 July 2017
Annual Inspection · DAPI Audit
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 6215371
07 - Fire Safety › N/A - No Subsystem › Fixed fire extinguishing installation
Issued 15 September 2022
Resolved
A pre-engineered fixed gas fire extinguishing system must automatically shut down all engines. System must have the following: a means to reset devices used to automatically shut down engines. During operational test of system, noticed that automatic shut down was intermittently working making system unreliable. Repair/replace and conduct operational test to the satisfaction of attending MI.
Condition: Improper/Lack of Maintenance
Action required: 60 - Rectify deficiencies prior to movement
Due 15 September 2022
Resolved 29 September 2022
Resolution: Repaired and tested. All sat.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 15 September 2022
Resolved
Each life preserver carried on a vessel must have at least 31 sq. in. of retroreflective material. Found 03 life preservers with worn retroreflective material. Life preservers replaced. Corrected on the spot.
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Resolved 15 September 2022
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 13 July 2021
Resolved
A vessel of not more than 26' in length must carry a minimum of one life buoy of not less than 24" in diameter. Vessel's ring buoy was deteriated and no longer servicable. Replace ring buoy and properly install prior to carriage of passengers.
Action required: 701 - Prior to carriage of passengers/cargo
Due 13 July 2021
Resolved 13 July 2021
01 - Certificates & Documentation › 012 - Crew Certificates › Record of employment
Issued 13 July 2021
Resolved
Employers must maintain records of chemical tests as provided in 49 CFR 40.333 and must make these records available to Coast Guard officals upon request. Vessel was unable to provide current evidence of enrollment into a drug and alcohol testing program.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 13 August 2021
Resolved 14 July 2021
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 5 June 2019
Resolved
PRIOR TO CARRYING PASSENGERS FIND AND REPAIR SOURCE OF FUEL LEAK.
Condition: Placed in Improper Service
Action required: 701 - Prior to carriage of passengers/cargo
Due 5 June 2019
Resolved 1 July 2019
Resolution: Fuel tank repaired, inspected, and reinstalled.
11 - Life Saving Appliances › N/A - No Subsystem › Distress flares
Issued 4 October 2018
Resolved
Vessels on Lakes, Bays, and Sounds routes must carry three red hand flares and three hand orange smoke distress signals. The vessel did not have three orange hand smoke distress signals. Rectify prior to carrying passengers.
Condition: Invalid
Action required: 701 - Prior to carriage of passengers/cargo
Due 31 October 2018
Resolved 5 October 2018
Resolution: Vessel provided proof that a sufficient number of distress signals were on board.
01 - Certificates & Documentation › 011 - Ships Certificates › Certificate of Inspection (COI)
Issued 10 July 2018
Resolved
Vessel is overdue for drydock and internal structural exams. Conduct DD/ISE exams prior to operating with more than 6 passengers.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 24 July 2018