MAURY USCG vessel records Sign in
← All vessels

ISLANDER

ISLANDER is a 1983 passenger vessel (inspected). The Coast Guard has recorded 62 inspections since 1985, most recently in May 2024, along with 60 deficiencies and 1 casualty investigation in 2008.

Records from 1985 to 2024. Most recent: inspection, 1 May 2024.

Built
1983
Last inspected
1 May 2024
Documentation
Valid · documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

WRB9567
Flag
UNITED STATES
367327770
Maury page id
psix-54946

Inspections, by type

…with no type recorded6
Years with a record 35 calendar years (1985–2024)
The 62 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 1977.

Documentation record

Registered dimensions (L × B × D)85.8 ft × 36.1 ft × 7.1 ft
Registered tonnagegross 92 / net 62
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderG & W INDUSTRIES INC · CLEVELAND, OH, UNITED STATES · built 1983
Hull materialSteel
PropulsionDiesel Reduction
Hull shapeNot recorded
Hull configurationNot recorded
Hailing portPUT-IN-BAY, OH
Trade endorsementsCoastwise, unrestricted, Registry
DocumentationValid · issued 10 February 2026 · expires 28 February 2027
Service, as the file records itPassenger (Inspected)
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it92 - Regulatory (Subpart C or D), Gross Ton
62 - Regulatory (Subpart C or D), Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 September 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.

Radio station licence

WRB9567MMSI 367327770 · active · compulsorily equipped · granted 16 February 2018, expires 3 March 2028
WAL6214MMSI not assigned · expired · compulsorily equipped · granted 24 March 1995, cancelled 23 July 2005
FCC Universal Licensing System ship-station file of 6 September 2026, matched to this hull on its US Official Number. Status and dates are the file’s own. The licensee is not read from the file and is not shown. A lapsed licence’s MMSI is still the number the vessel transmitted under while it was valid.

Inspection history · 62

1 May 2024 Annual Inspection
Physical examination · Marine Safety Unit Toledo · USCG Great Lakes District (CGD-GL) · Activity 7905408
26 April 2023 Annual Inspection · DAPI Audit · MTSA Verification
Physical examination · Marine Safety Unit Toledo · USCG Great Lakes District (CGD-GL) · Activity 7676084
2 November 2022 Administrative Inspection · Internal Structural Exam · COI Inspection · Drydock Exam
Physical examination · Marine Safety Unit Cleveland · USCG Great Lakes District (CGD-GL) · Activity 7588078
20 April 2022 DAPI Audit · COI Inspection
Physical examination · Marine Safety Unit Toledo · USCG Great Lakes District (CGD-GL) · Activity 7434462
11 May 2021 Administrative Inspection
Administrative · Marine Safety Unit Toledo · USCG Great Lakes District (CGD-GL) · Activity 7194130
29 April 2021 Annual Inspection · MTSA Verification
Physical examination · Marine Safety Unit Toledo · USCG Great Lakes District (CGD-GL) · Activity 7187885
21 July 2020 Annual Inspection
Physical examination · Marine Safety Unit Toledo · USCG Great Lakes District (CGD-GL) · Activity 7011902
24 April 2019 Annual Inspection · MTSA Verification
Physical examination · Marine Safety Unit Toledo · USCG Great Lakes District (CGD-GL) · Activity 6670934
10 May 2018 Annual Inspection · Deficiency Check · MTSA Verification
Physical examination · Marine Safety Unit Toledo · USCG Great Lakes District (CGD-GL) · Activity 6411291
19 October 2017 Drydock Exam · Internal Structural Exam · COI Inspection
Physical examination · Marine Safety Unit Cleveland · USCG Great Lakes District (CGD-GL) · Activity 6294056
24 March 2017 MTSA Verification · COI Inspection
Physical examination · Marine Safety Unit Toledo · USCG Great Lakes District (CGD-GL) · Activity 6108732
2 November 2016 MTSA Verification
Physical examination · Marine Safety Unit Toledo · USCG Great Lakes District (CGD-GL) · Activity 6033750
26 April 2016 Annual Inspection
Physical examination · Marine Safety Unit Toledo · USCG Great Lakes District (CGD-GL) · Activity 5862620
13 May 2014 Drydock Exam · Internal Structural Exam
Physical examination · Marine Safety Unit Cleveland · USCG Great Lakes District (CGD-GL) · Activity 4856372
29 April 2009 Annual Inspection
Physical examination · Marine Safety Unit Toledo · USCG Great Lakes District (CGD-GL) · Activity 3453913
30 May 2008 In-Service Inspection
Physical examination · Marine Safety Unit Toledo · USCG Great Lakes District (CGD-GL) · Activity 3222079
26 May 2008 Type not recorded
No type recorded · Marine Safety Unit Toledo · USCG Great Lakes District (CGD-GL) · Activity 3239806
20 May 2008 Deficiency Check
Physical examination · Marine Safety Unit Toledo · USCG Great Lakes District (CGD-GL) · Activity 3212657
1 May 2008 Annual Inspection
Physical examination · Marine Safety Unit Toledo · USCG Great Lakes District (CGD-GL) · Activity 3196237
16 April 2008 Drydock Exam · Internal Structural Exam
Physical examination · Marine Safety Unit Toledo · USCG Great Lakes District (CGD-GL) · Activity 3168277
30 May 2007 Administrative Inspection
Administrative · Marine Safety Unit Toledo · USCG Great Lakes District (CGD-GL) · Activity 2946203
16 May 2007 Deficiency Check
Physical examination · Marine Safety Unit Toledo · USCG Great Lakes District (CGD-GL) · Activity 2932128
11 April 2007 COI Inspection · MTSA/ISPS Verification
Physical examination · Marine Safety Unit Toledo · USCG Great Lakes District (CGD-GL) · Activity 2905683
5 May 2006 Deficiency Check
Physical examination · Marine Safety Unit Toledo · USCG Great Lakes District (CGD-GL) · Activity 2641267
19 April 2006 Annual Inspection · MTSA/ISPS Verification
Physical examination · Marine Safety Unit Toledo · USCG Great Lakes District (CGD-GL) · Activity 2628419
18 April 2005 Annual Inspection · MTSA Verification
Physical examination · Marine Safety Unit Toledo · USCG Great Lakes District (CGD-GL) · Activity 2336189
26 July 2004 Deficiency Check
Physical examination · Marine Safety Unit Toledo · USCG Great Lakes District (CGD-GL) · Activity 2145998
27 April 2004 Annual Inspection
Physical examination · Marine Safety Unit Toledo · USCG Great Lakes District (CGD-GL) · Activity 2053540
22 December 2003 Security Plan Review - ASP
Administrative · Marine Safety Center (MSC) · Activity 1969270
16 June 2003 Deficiency Check
Physical examination · Marine Safety Unit Toledo · USCG Great Lakes District (CGD-GL) · Activity 1819135
7 May 2003 Annual Inspection
Physical examination · Marine Safety Unit Toledo · USCG Great Lakes District (CGD-GL) · Activity 1788150
6 March 2003 Administrative Inspection
Administrative · Marine Safety Unit Toledo · USCG Great Lakes District (CGD-GL) · Activity 1753578
12 November 2002 Hull Examination
Physical examination · MSO DETROIT · USCG Great Lakes District (CGD-GL) · Activity 1704052
24 September 2002 Internal Structural Exam
Physical examination · Marine Safety Unit Toledo · USCG Great Lakes District (CGD-GL) · Activity 1674649
16 April 2002 COI Inspection
Physical examination · Marine Safety Unit Toledo · USCG Great Lakes District (CGD-GL) · Activity 1605557
24 April 2001 Re-Inspection
Physical examination · Marine Safety Unit Toledo · USCG Great Lakes District (CGD-GL) · Activity 1435187
20 April 2000 Re-Inspection
Physical examination · Marine Safety Unit Toledo · USCG Great Lakes District (CGD-GL) · Activity 1448103
27 May 1999 Type not recorded
No type recorded · Marine Safety Unit Toledo · USCG Great Lakes District (CGD-GL) · Activity 730977
5 May 1999 Type not recorded
No type recorded · Marine Safety Unit Toledo · USCG Great Lakes District (CGD-GL) · Activity 212200
21 April 1999 Plan Review "T" Boat · COI Inspection
Physical examination · Marine Safety Unit Toledo · USCG Great Lakes District (CGD-GL) · Activity 790051
22 April 1998 Re-Inspection
Physical examination · Marine Safety Unit Toledo · USCG Great Lakes District (CGD-GL) · Activity 1124740
9 October 1997 Hull Examination
Physical examination · MSO DETROIT · USCG Great Lakes District (CGD-GL) · Activity 1470700
23 April 1997 Re-Inspection
Physical examination · Marine Safety Unit Toledo · USCG Great Lakes District (CGD-GL) · Activity 1129615
25 April 1996 COI Inspection
Physical examination · Marine Safety Unit Toledo · USCG Great Lakes District (CGD-GL) · Activity 1083635
26 April 1995 COI Inspection
Physical examination · Marine Safety Unit Toledo · USCG Great Lakes District (CGD-GL) · Activity 1434242
26 April 1994 COI Inspection
Physical examination · Marine Safety Unit Toledo · USCG Great Lakes District (CGD-GL) · Activity 1449690
27 April 1993 COI Inspection
Physical examination · Marine Safety Unit Toledo · USCG Great Lakes District (CGD-GL) · Activity 833689
1 October 1992 Hull Examination
Physical examination · MSO DETROIT · USCG Great Lakes District (CGD-GL) · Activity 1389584
1 May 1992 COI Inspection
Physical examination · Marine Safety Unit Toledo · USCG Great Lakes District (CGD-GL) · Activity 949081
11 June 1991 Type not recorded
No type recorded · Marine Safety Unit Toledo · USCG Great Lakes District (CGD-GL) · Activity 129284
3 May 1991 COI Inspection
Physical examination · Marine Safety Unit Toledo · USCG Great Lakes District (CGD-GL) · Activity 1232074
3 May 1990 COI Inspection
Physical examination · Marine Safety Unit Toledo · USCG Great Lakes District (CGD-GL) · Activity 910855
3 April 1989 COI Inspection
Physical examination · Marine Safety Unit Toledo · USCG Great Lakes District (CGD-GL) · Activity 1349342
20 April 1988 Type not recorded
No type recorded · Marine Safety Unit Toledo · USCG Great Lakes District (CGD-GL) · Activity 1345986
4 April 1988 COI Inspection
Physical examination · Marine Safety Unit Toledo · USCG Great Lakes District (CGD-GL) · Activity 999661
11 December 1987 Administrative
Administrative · MSO DETROIT · USCG Great Lakes District (CGD-GL) · Activity 1002061
8 November 1987 Hull Examination
Physical examination · MSO DETROIT · USCG Great Lakes District (CGD-GL) · Activity 1000333
7 October 1987 Administrative
Administrative · Marine Safety Unit Toledo · USCG Great Lakes District (CGD-GL) · Activity 1321149
7 October 1987 Administrative
Administrative · Marine Safety Unit Toledo · USCG Great Lakes District (CGD-GL) · Activity 1325493
7 April 1987 COI Inspection
Physical examination · Marine Safety Unit Toledo · USCG Great Lakes District (CGD-GL) · Activity 1020641
1 May 1986 COI Inspection
Physical examination · Marine Safety Unit Toledo · USCG Great Lakes District (CGD-GL) · Activity 1000711
1 May 1985 Type not recorded
No type recorded · Marine Safety Unit Toledo · USCG Great Lakes District (CGD-GL) · Activity 980052

Deficiency record · 60

Engineering › Gasoline Engine (auxiliary) › Fuel Intake (2 stroke)
Issued 10 May 2018 Resolved
Vessel's starboard-side ballast/bilge pump has a fuel line that was observed spraying fuel while operating. This pump shall not be run until the fuel line is replaced, and does not spray fuel. Until the fixed pump can be run, the vessel shall carry a powered portable pump that could be satisfactorily used for de-watering purposes in lieu of the fixed pump.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 10 June 2018
Resolved 24 May 2018
Resolution: Affected fuel line was replaced. Pump was run without fuel leak or issue.
Fire Fighting › Fixed Pressure Water-Spraying Fire Extinguishing System › Nozzles
Issued 26 April 2016 Resolved
One (01) sprinkler head on the port-side auto-deck was clogged with rust/sediment. Clean out rust/sediment and demonstrate proper operation IAW 46 CFR 181.400(g).
Action required: 705 - Other - as specified
Due 26 April 2016
Resolved 26 April 2016
Resolution: Corrected during the inspection.
Electrical › Lighting (service) › Lighting Fixture
Issued 1 May 2008 Resolved
Install proper lighting fixtures where needed.
Condition: Unknown
Action required: 705 - Other - as specified
Due 31 May 2008
Resolved 20 May 2008
Electrical › Electrical Distribution System (service) › Wiring
Issued 1 May 2008 Resolved
Properly hang rudder angle indicator wiring.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 31 May 2008
Resolved 20 May 2008
Engineering › Fuel Oil Storage/Transfer System › Piping
Issued 1 May 2008 Resolved
Install fuel line support bracket on fuel line in aft stbd void.
Action required: 705 - Other - as specified
Due 31 May 2008
Resolved 20 May 2008
Engineering › Bilge Water Management System › Not Installed
Issued 1 May 2008 Resolved
Install screw type valve on overboard discharge for lazarette bilge pump.
Condition: Unknown
Action required: 705 - Other - as specified
Due 31 May 2008
Resolved 20 May 2008
Engineering › Diesel Engine (propulsion/auxiliary-electric) › Air Cleaner
Issued 16 April 2007 Resolved
Replace air filter and crank case foam filter, remove loose paint
Action required: 705 - Other - as specified
Due 16 May 2007
Resolved 10 May 2007
Accommodation/Occupational Safety › Occupational Safety › Guards for Exposed Hazards
Issued 16 April 2007 Resolved
Isuzu belt guard fractured
Action required: 705 - Other - as specified
Due 16 May 2007
Resolved 10 May 2007
Engineering › Steering Gear System › Rudder
Issued 16 April 2007 Resolved
Replace rudder stops - wood worn
Action required: 705 - Other - as specified
Due 16 May 2007
Resolved 10 May 2007
Pollution Prevention/Response › Prevention Equipment › Bilge Monitor
Issued 16 April 2007 Resolved
Permanently wire sump pump aft
Action required: 705 - Other - as specified
Due 16 May 2007
Resolved 10 May 2007
Engineering › Bilge Water Management System › Strainer
Issued 16 April 2007 Resolved
Clear debris form bilge suction area.
Action required: 705 - Other - as specified
Due 16 May 2007
Resolved 10 May 2007
Fire Fighting › Portable CO2 Fire Extinguisher › Service
Issued 16 April 2007 Resolved
Have fixed/portable fire extinguishers serviced, provide proof to MSU
Action required: 705 - Other - as specified
Due 30 April 2007
Resolved 10 May 2007
Lifesaving › Lifebuoys › Serviceable
Issued 16 April 2007 Resolved
Life ring was cracked around the majority of the inside of the ring. Replace
Action required: 705 - Other - as specified
Due 16 May 2007
Resolved 10 May 2007
Lifesaving › Lifejacket/PFD (General) › Retroreflective Material
Issued 16 April 2007 Resolved
Repair the retro-reflective materal on 175 adult life jacktes. THIS MUST BE COMPLETED PRIOR TO CARRYING ALOTED PASSENGERS ON THE COI. PASSENGER COUNT IS REDUCED TO 269 UNTIL COMPLETED.
Due 16 May 2007
Resolved 10 May 2007
Lifesaving › Lifejacket/PFD (General) › Retroreflective Material
Issued 16 April 2007 Resolved
Repair retro-reflective material on 21 child lifejackets.
Action required: 705 - Other - as specified
Due 16 April 2007
Resolved 10 May 2007
Navigation › Piloting/Steering › Magnetic Compass
Issued 16 April 2007 Resolved
Replace/Repair bulb in compass
Action required: 705 - Other - as specified
Due 16 April 2007
Resolved 10 May 2007
Fire Fighting › Fixed Pressure Water-Spraying Fire Extinguishing System › Nozzles
Issued 16 April 2007 Resolved
Repair three (3) sprinkler heads in the car deck area.
Action required: 705 - Other - as specified
Due 16 May 2007
Resolved 10 May 2007
Lifesaving › Lifefloat › Markings
Issued 19 April 2006 Resolved
Stencil vessel name on 11 topside life-floats.
Due 18 May 2006
Resolved 4 May 2006
Resolution: Vessels rep''s stenciled name on all topside life-floats.
Fire Fighting › Portable CO2 Fire Extinguisher › Marking
Issued 19 April 2006 Resolved
Label fire ax station.
Due 18 May 2006
Resolved 4 May 2006
Resolution: Vessels rep''s labeled fire ax on the bridge, all sat.
Lifesaving › Lifefloat › Floating Electric Waterlight
Issued 19 April 2006 Resolved
Ensure that all the vessel's life floats have individual float lights attached as per 46 CFR 180.15-1 and 46 CFR 180.15-5.
Due 4 May 2006
Resolved 4 May 2006
Resolution: Vessels rep''s added new lights to all floats, I tested all new lights sat.
Engineering › Diesel Engine (propulsion-reduction gear) › Pump, High Pressure (fuel injection)
Issued 18 April 2005 Resolved
Starboard MDE Racor assmy missing metal fire bowl protector.
Condition: Placed in Improper Service
Action required: 701 - Prior to carriage of passengers/cargo
Due 29 April 2005
Resolved 17 May 2005
Resolution: Millers crew installed a new fire bowl to the racor filter.
Engineering › Diesel Engine (propulsion-reduction gear) › Pump, Positive Displacement
Issued 18 April 2005 Resolved
Port MDE missing a cap on the oil drain line from the oil filter housing, also the valve handle is missing and needs to be re-installed.
Condition: Placed in Improper Service
Action required: 701 - Prior to carriage of passengers/cargo
Due 29 April 2005
Resolved 17 May 2005
Resolution: Millers crew added a nipple and a cap to both port and stbd side oil filter housing drains.
Engineering › Diesel Engine (propulsion-reduction gear) › Piping (air intake)
Issued 18 April 2005 Resolved
24 VDC main diesel engine blower emergency shut downs on both main diesel engines not working, both need to be operational.
Condition: Placed in Improper Service
Action required: 701 - Prior to carriage of passengers/cargo
Due 29 April 2005
Resolved 17 May 2005
Resolution: Millers crew replaced stbd diesel 24 volt shut down, and repaired port side, tested both sides with sat results.
Electrical › Electrical Distribution System (service) › Non-conducting Deck Covering
Issued 18 April 2005 Resolved
Generator distrubution panel has no matting under the switch boards.
Condition: Improper Installation
Due 29 April 2005
Resolved 17 May 2005
Resolution: Millers crew installed a new mat for the dist panels.
Electrical › Electrical Distribution System (service) › Junction Box
Issued 18 April 2005 Resolved
Shore tie connection junction box cover is missing.
Condition: Improper Installation
Due 29 April 2005
Resolved 17 May 2005
Resolution: Millers crew installed a new cover on the shore tie box.
Electrical › Lighting (service) › Lighting Fixture
Issued 18 April 2005 Resolved
All deck lights need to be in working condition. Many deck light where ooc and need to be repaired.
Condition: Improper/Lack of Maintenance
Due 29 April 2005
Resolved 17 May 2005
Resolution: Millers crew repaired all ooc lights, all tested sat.
Deck/Cargo › Cargo Stowage › General
Issued 18 April 2005 Resolved
Fuel oil shut offs are too hard to actuate, need to free up the reach rods for smooth operation.
Condition: Improper/Lack of Maintenance
Due 29 April 2005
Resolved 17 May 2005
Resolution: Tested fuel shut offs with sat resuts, crew greased and pm''d the remote systems.
Deck/Cargo › Holds/Tanks › Flame Arrester
Issued 18 April 2005 Resolved
Need to install flame screens on all fuel oil vent goose necks.
Condition: Improper Installation
Due 29 April 2005
Resolved 17 May 2005
Resolution: Millers crew installed flame screens in the goose necks with sat results.
Accommodation/Occupational Safety › Occupational Safety › Smoking
Issued 18 April 2005 Resolved
Need to install no smoking signs on deck, signs are missing.
Condition: Improper Installation
Due 29 April 2005
Resolved 17 May 2005
Resolution: Millers crew added 2 new signs to the vehicle deck area.
Personnel › Certificates/Documents/Licenses › License, GMDSS Radio Operator
Issued 18 April 2005 Resolved
Radio permit was not on board at the time of the inspection.
Condition: Unknown
Due 29 April 2005
Resolved 17 May 2005
Resolution: Radio permit was inspected on board with the expiration of 2010.
Lifesaving › Hand Flares › Expired
Issued 18 April 2005 Resolved
All day flares out of date, the Miller company has the flares on order direct from the factory
Condition: Placed in Improper Service
Action required: 701 - Prior to carriage of passengers/cargo
Due 29 April 2005
Resolved 17 May 2005
Resolution: Millers crew purchased new day flares with the expiration of 09/2008.
Engineering › Steering Gear System › Rudder
Issued 29 April 2004 Resolved
Condition: Improper/Lack of Maintenance
Due 29 May 2004
Resolved 26 July 2004
Lifesaving › Buoyant Apparatus › Marking
Issued 27 April 2004 Resolved
Label paddles, renew retro, coil line, and label with vessels name. LEGACY COMPONENT DESC: Outfitting
Condition: Unknown
Due 29 May 2004
Resolved 26 July 2004
Engineering › Fuel Oil Storage/Transfer System › Piping
Issued 27 April 2004 Resolved
Label all F/O shut-off's on Main Deck
Condition: Improper/Lack of Maintenance
Due 29 May 2004
Resolved 26 July 2004
Engineering › Generator (propulsion/auxiliary-electric) › Heating Element Circuitry
Issued 27 April 2004 Resolved
Install lagging on stand-by generator. LEGACY COMPONENT DESC: Insulation
Condition: Unknown
Due 29 May 2004
Resolved 26 July 2004
Construction/Loadline › Markings › Draft Marks/Indicating System
Issued 27 April 2004 Resolved
Proper installation of loading marks on hull.
Condition: Unknown
Due 29 May 2004
Resolved 26 July 2004
Engineering › Diesel Engine (propulsion-direct drive) › Crankcase
Issued 27 April 2004 Resolved
Prove proper operation of F/O pressure gauges for both main diesel engines. LEGACY COMPONENT DESC: Gauges
Condition: Unknown
Due 29 May 2004
Resolved 26 July 2004
Operations/Management › Passenger Operations › Safety Orientation
Issued 27 April 2004 Resolved
Passenger orientation is provided via loud speaker in waiting area prior to boarding. When we conducted inspection the orientation could bearly be heard and did not cover all of the required areas.
Due 29 May 2004
Resolved 26 July 2004
Fire Fighting › Fire Pumps
Issued 7 May 2003 Resolved
Install pressure gauge on the stbd fire pump. LEGACY COMPONENT DESC: Pressure guage
Condition: Placed in Improper Service
Due 7 June 2003
Resolved 3 July 2003
Electrical › Electric Generation Source (service)
Issued 7 May 2003 Resolved
Install a guard on the aux generator pulleys and repair leak in the exhaust system. LEGACY COMPONENT DESC: guards
Condition: Placed in Improper Service
Due 7 June 2003
Resolved 13 June 2003
Engineering › Shafting/Propeller Arrangements › Propeller Shaft
Issued 12 November 2002 Resolved
Renew both propulsion shafts.
Due 6 December 2002
Resolved 6 December 2002
Operations/Management › Passenger Operations › Safety Orientation
Issued 17 April 2002 Resolved
Safety orientation was not being done.
Due 17 April 2002
Resolved 17 April 2002
Lifesaving › Lifejacket/PFD (Type I) › Condition
Issued 16 April 2002 Resolved
Replaced 07 adult and 01 child PFD's.
Condition: Improper/Lack of Maintenance
Due 17 April 2002
Resolved 17 April 2002
Lifesaving › Buoyant Apparatus
Issued 16 April 2002 Resolved
Replaced 2, 20 person BA's with 2, 24 person Life Floats due to weathered condition of BA's.
Condition: Improper/Lack of Maintenance
Due 17 April 2002
Resolved 17 April 2002
Lifesaving
Issued 24 April 2001 Resolved
Persons allowed onboard is reduced to 220 including crew until new life float is placed on board.
Condition: Unknown
Due 3 May 2001
Resolved 4 May 2001
Lifesaving
Issued 21 April 1999 Resolved
PROVIDE CAT I 406 EPIRB ON BOARD. VESSEL IS RESTRICTED TO WITHIN 3 MILES FROM SHORE UNTIL NEW 406 EPIRB IS ON BOARD.
Condition: Unknown
Due 21 May 1999
Resolved 3 May 1999
Lifesaving
Issued 27 April 1993 Resolved
RECONFIGURE RELEASE DEVICE ON B/A TO ALLOW EASY RELEASE OF BOYANT APPERATUSAND TO ALLOW B/A TO FLOAT FREE
Condition: Unknown
Due 27 April 1993
Resolved 27 April 1993
Construction/Loadline
Issued 27 April 1993 Resolved
NO HAND OPERATED PUMP ON BOARD.
Condition: Unknown
Due 27 April 1993
Resolved 27 April 1993
Lifesaving
Issued 27 April 1993 Resolved
REPLACE OR REPAIR 2 LIFE RINGS
Condition: Unknown
Due 27 April 1993
Resolved 27 April 1993
Construction/Loadline
Issued 27 April 1993 Resolved
REPAIR EXHAUST LEAK ON LISTER PUMP
Condition: Unknown
Due 27 April 1993
Resolved 27 April 1993
Engineering
Issued 1 October 1992 Resolved
RESTENCIL BOTH EMERGENCY FUEL SHUTOFF SIGNS._x001C_ _x001C_ _x001C_ _x001C_
Condition: Unknown
Due 1 October 1992
Resolved 1 October 1992
Lifesaving
Issued 1 May 1992 Resolved
CONDUCT UNDERWAY DRILLS FOR MAN-OVERBOARD, FIRE, AND FLOODING. ITEMS TO BECOMPETED PRIOR TO 31 MAY 1992._x001C_ _x001C_ _x001C_
Condition: Unknown
Due 21 May 1992
Resolved 27 May 1992
Lifesaving
Issued 4 April 1988 Resolved
REPLACE RING BOUY ON CAR DECK.
Condition: Unknown
Due 4 April 1988
Resolved 4 April 1988
Navigation
Issued 4 April 1988 Resolved
REPLACE STEERING GEAR PUMP GAUGE.
Condition: Unknown
Due 4 April 1988
Resolved 4 April 1988
Fire Fighting
Issued 4 April 1988 Resolved
SERVICE FWD P/S PORTABLE FIRE EXTINGISHERS LOCATED ON THE CAR DECK.
Condition: Unknown
Due 4 April 1988
Resolved 4 April 1988
Lifesaving
Issued 7 April 1987 Resolved
REPLACE ALL LIFE LINES ON ALL BUOYANT APPARATUS.
Condition: Unknown
Due 7 April 1987
Resolved 7 April 1987
Engineering
Issued 7 April 1987 Resolved
CORRECTLY REINSTALL OIL DRAIN LINE TO BOTH MAIN ENGINE LUBE OIL FILTERS.
Condition: Unknown
Due 7 April 1987
Resolved 7 April 1987
Engineering
Issued 7 April 1987 Resolved
REPLACE OR REPAIR LOW FUEL OIL ALARM SENSOR ON STBD. MAIN ENGINE.
Condition: Unknown
Due 7 April 1987
Resolved 7 April 1987
Electrical
Issued 7 April 1987 Resolved
REPAIR BROKEN BELT GUARD ON AUX. GENERATOR ANDF SMALL AIR COMPRESSOR.
Condition: Unknown
Due 7 April 1987
Resolved 7 April 1987
Engineering
Issued 1 May 1986 Resolved
INSTALL SOLDER TYPE BATTERY CONNECTIONS.
Condition: Unknown
Due 1 May 1986
Resolved 1 May 1986

Casualty record · 1

26 May 2008Routine · role: Involved in a Marine Casualty · activity 3239806
Each line is an incident investigation the Coast Guard recorded with this hull among the vessels involved, with the date and the classification the Coast Guard gave it, and the bridge, lock or dam the investigation names where it names one. Involvement is not fault. The investigation narrative is not published. Source: IIR, through 2026.

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.