Records from 1983 to 1987. Most recent: inspection, 21 September 1987.
A report is not offered for this hull: Its record holds only 2 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. Reports.
Deck/Cargo
Issued 19 October 1986
Resolved
REPLACE 3 SHOTS OF ANCHOR CHAIN (PORT) STARTING AT ANCHOR END.
Condition: Unknown
Due 25 November 1986
Resolved 18 May 2002
Resolution: MISLE Maintenance - Resolved all open deficiencies issued prior to 6/1/1997 where activity was closed and deficiency due date was past
Fire Fighting
Issued 19 October 1986
Resolved
REPLACE CRACKED AND RUSTY PIGTAIL ON FIXED CO2 SYSTEM TO PAINT LOCKER.
Condition: Unknown
Due 21 November 1986
Resolved 18 May 2002
Resolution: MISLE Maintenance - Resolved all open deficiencies issued prior to 6/1/1997 where activity was closed and deficiency due date was past
Engineering
Issued 19 October 1986
Resolved
ASSEMBLE AND TEST PORT MAIN ENGINE TO THE SATISFACTION OF A U.S. COAST GUARD MARINE INSPECTOR.
Condition: Unknown
Due 21 November 1986
Resolved 18 May 2002
Resolution: MISLE Maintenance - Resolved all open deficiencies issued prior to 6/1/1997 where activity was closed and deficiency due date was past
Deck/Cargo
Issued 26 February 1986
Resolved
CONDUCT HYDRO TEST OR INTERNAL EXAMINATION OF BULK TANKS NOS. 28620 AND 28621.
Condition: Unknown
Due 26 February 1986
Resolved 26 February 1986
Deck/Cargo
Issued 26 February 1986
Resolved
PROVE OPERATION OF RELIEF VALVES FOR BULK TANKS NOS. 28620 AND 28621
Condition: Unknown
Due 26 February 1986
Resolved 26 February 1986
Navigation
Issued 16 April 1985
Resolved
PROVIDE VISIBLE ALARM IN WHEEL HOUSE WHICH ACTIVATES UPON LOSS OF POWER TO STEERING GEAR.
Condition: Unknown
Due 16 April 1985
Resolved 16 April 1985
Electrical
Issued 16 April 1985
Resolved
PROVE OPERATION OF OVERSPEED TRIPS AND LOW LUBE OIL ALARMS FOR BOTH SHIP SERVICE GENERATORS.
Condition: Unknown
Due 16 April 1985
Resolved 16 April 1985
Documentation
Issued 16 April 1985
Resolved
PROVIDE LATEST SAILING DIRECTIONS, TIDE TABLE, AND CURRENT TABLES FOR NORTHAFRICA.
Condition: Unknown
Due 16 April 1985
Resolved 16 April 1985
Lifesaving
Issued 16 April 1985
Resolved
PROVIDE ANNUAL SERVICING OF BOTH LIFERAFTS AND HYDROSTATIC RELEASES.
Condition: Unknown
Due 16 April 1985
Resolved 16 April 1985
Electrical
Issued 16 April 1985
Resolved
PROVIDE ONE LIGHT FOR ENGINE ROOM ESCAPE TRUNK ON EMERGENCY CIRCUIT.
Condition: Unknown
Due 16 April 1985
Resolved 16 April 1985
Accommodation/Occupational Safety
Issued 16 April 1985
Resolved
PROVIDE RELIEF VALVE FOR REEFER COMPRESSOR AS PER 46 CFR 58.28-20(C).
Condition: Unknown
Due 16 April 1985
Resolved 16 April 1985
Electrical
Issued 16 April 1985
Resolved
PROVE OPERATION AND PROVIDE PROTECTION FROM CORROSION OF REMOTE SHUT DOWN FOR FUEL OIL TRANSFER PUMPS, LIQUID MUD PUMPS AND MACHINERY SPACE VENTILATION.
Condition: Unknown
Due 16 April 1985
Resolved 16 April 1985
Fire Fighting
Issued 16 April 1985
Resolved
CONDUCT ANNUAL SERVICING OF FIXED AND PORTABLE FIRE EXTINGUISHING EQUIPMENT.
Condition: Unknown
Due 16 April 1985
Resolved 16 April 1985
Lifesaving
Issued 16 April 1985
Resolved
PROVIDE COAST GUARD APPROVED WATER LIGHT FOR 6 MAN BUOYANT APPARATUS, AND STOW APPARATUS AND PAINTER AS PER 46 CFR 94.20-35.
Condition: Unknown
Due 16 April 1985
Resolved 16 April 1985
Lifesaving
Issued 16 April 1985
Resolved
PROVIDE ONE 500' AUXILIARY LINE FOR LINE THROWING APPLIANCE.
Condition: Unknown
Due 16 April 1985
Resolved 16 April 1985
Lifesaving
Issued 16 April 1985
Resolved
PROVIDE FULL COMPLEMENT OF 21 LIFEJACKETS WITH LIGHTS, TAPS, AND MARKINGS PRIOR TO CARRYING MORE THAN 16 PERSONS.
Condition: Unknown
Due 16 April 1985
Resolved 16 April 1985
Lifesaving
Issued 16 April 1985
Resolved
PROVIDE RESCUE BOAT AND LAUNCHING DEVICE AS PER 46 CFR 94.10-55(B)(1)(III).
Condition: Unknown
Due 16 April 1985
Resolved 16 April 1985
Lifesaving
Issued 16 April 1985
Resolved
RE-LOCATE STOWAGE OF LIFERAFTS TO ENSURE SAFE AND RAPID LAUNCH, AS PER 46 CFR 94.15-10.
Condition: Unknown
Due 16 April 1985
Resolved 16 April 1985
Lifesaving
Issued 16 April 1985
Resolved
RE-LOCATE LIFERAFT ILLUMINATION TO PROVIDE SERVICE AT BOTH LAUNCHING SITES AND DEPLOYMENT SITE AS PER 46 CFR 111.75-16.
Condition: Unknown
Due 16 April 1985
Resolved 16 April 1985
Engineering
Issued 16 April 1985
Resolved
PROVE OPERATION OF PORT PROPULSION ENGINE LOW LUBE OIL ALARM.
Condition: Unknown
Due 16 April 1985
Resolved 16 April 1985
Engineering
Issued 16 April 1985
Resolved
CONDUCT BIENNIAL HYDRO TEST OR INTERNAL EXAMINATION OF 2 AIR RECEIVERS AND 4 BULK TANKS.
Condition: Unknown
Due 16 April 1985
Resolved 16 April 1985
Deck/Cargo
Issued 16 April 1985
Resolved
PROVE OPERATION OF UNTESTED RELIEF VALVES FOR 4 BULK STORAGE TANKS AND SMALL UNINSPECTED AIR RECEIVER.
Condition: Unknown
Due 16 April 1985
Resolved 16 April 1985