MAURY USCG vessel records Sign in
← All vessels

VONDA KAY

VONDA KAY is a 1976 passenger vessel (inspected). The Coast Guard has recorded 86 inspections since 1985, most recently in March 2026, along with 199 deficiencies and 7 casualty investigations between 2009 and 2026.

Records from 1985 to 2026. Most recent: inspection, 30 March 2026.

Built
1976
Last inspected
30 March 2026
Documentation
Valid · documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

WCZ3557
Flag
UNITED STATES
367413590
Maury page id
psix-54954

Inspections, by type

…with no type recorded12
Years with a record 38 calendar years (1985–2026)
The 86 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 1977.

Documentation record

Registered dimensions (L × B × D)58.8 ft × 18.9 ft × 7.0 ft
Registered tonnagegross 67 / net 47
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderSTAPLETON BOAT CORP · MIAMI FL, UNITED STATES · built 1976
Hull materialFRP (Fiberglass)
PropulsionDiesel Reduction
Hull shapeNot recorded
Hull configurationNot recorded
Hailing portTOPSAIL BEACH, NC
Trade endorsementsCoastwise, unrestricted, Fishery, Recreational
DocumentationValid · issued 25 February 2026 · expires 28 February 2027
Service, as the file records itPassenger (Inspected)
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it67 - Regulatory (Subpart C or D), Gross Ton
47 - Regulatory (Subpart C or D), Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 September 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.

Radio station licence

WCZ3557MMSI 367413590 · active · compulsorily equipped · granted 27 April 2019, expires 28 June 2029
WCL5663MMSI not assigned · expired · compulsorily equipped · granted 12 August 1994, cancelled 16 October 2004 · licensed under a name not among this hull’s recorded names (not shown)
FCC Universal Licensing System ship-station file of 6 September 2026, matched to this hull on its US Official Number. Status and dates are the file’s own. The licensee is not read from the file and is not shown. A lapsed licence’s MMSI is still the number the vessel transmitted under while it was valid.

Inspection history · 86

30 March 2026 Internal Structural Exam · COI Inspection · Deficiency Check · Hull Examination · Vessel Attendance
Physical examination · Sector North Carolina · USCG East District (CGD-E) · Activity 8334108
10 January 2026 Deficiency Check · In-Service Inspection
Physical examination · Sector North Carolina · USCG East District (CGD-E) · Activity 8294216
10 January 2026 Type not recorded
No type recorded · Sector North Carolina · USCG East District (CGD-E) · Activity 8294902
13 May 2025 Deficiency Check · Annual Inspection
Physical examination · Sector North Carolina · USCG East District (CGD-E) · Activity 8134877
7 September 2024 Deficiency Check · In-Service Inspection
Physical examination · Sector North Carolina · USCG East District (CGD-E) · Activity 7998344
7 September 2024 Type not recorded
No type recorded · Sector North Carolina · USCG East District (CGD-E) · Activity 8004242
30 May 2024 Deficiency Check · Annual Inspection
Physical examination · Sector North Carolina · USCG East District (CGD-E) · Activity 7922956
19 April 2024 Drydock Exam · Internal Structural Exam · Hull Examination · Deficiency Check
Physical examination · Sector North Carolina · USCG East District (CGD-E) · Activity 7898033
1 August 2023 In-Service Inspection
Physical examination · Sector North Carolina · USCG East District (CGD-E) · Activity 7786342
1 May 2023 Annual Inspection · Deficiency Check
Physical examination · Sector North Carolina · USCG East District (CGD-E) · Activity 7678549
15 September 2022 Examination of Repairs · Damage Survey
Physical examination · Sector North Carolina · USCG East District (CGD-E) · Activity 7559863
15 September 2022 Type not recorded
No type recorded · Sector North Carolina · USCG East District (CGD-E) · Activity 7575335
7 June 2022 Deficiency Check · Annual Inspection
Physical examination · Sector North Carolina · USCG East District (CGD-E) · Activity 7470770
5 April 2022 Examination of Repairs · Hull Examination · Internal Structural Exam
Physical examination · Sector North Carolina · USCG East District (CGD-E) · Activity 7424762
13 June 2021 Deficiency Check · Administrative Inspection · Damage Survey
Physical examination · Sector North Carolina · USCG East District (CGD-E) · Activity 7223770
12 June 2021 Type not recorded
No type recorded · Sector North Carolina · USCG East District (CGD-E) · Activity 7261187
29 April 2021 Deficiency Check · COI Inspection · Administrative Inspection
Physical examination · Sector North Carolina · USCG East District (CGD-E) · Activity 7185310
11 August 2020 Annual Inspection · Deficiency Check
Physical examination · Sector North Carolina · USCG East District (CGD-E) · Activity 7029784
18 July 2020 Damage Survey · Deficiency Check
Physical examination · Sector North Carolina · USCG East District (CGD-E) · Activity 7009726
18 July 2020 Type not recorded
No type recorded · Sector North Carolina · USCG East District (CGD-E) · Activity 7011181
10 March 2020 Internal Structural Exam · Hull Examination · Administrative Inspection · Examination of Repairs · Drydock Exam
Physical examination · Sector North Carolina · USCG East District (CGD-E) · Activity 6923692
30 July 2019 Deficiency Check · Annual Inspection · Administrative Inspection
Physical examination · Sector North Carolina · USCG East District (CGD-E) · Activity 6766656
1 August 2018 Annual Inspection · Deficiency Check · Administrative Inspection
Physical examination · Sector North Carolina · USCG East District (CGD-E) · Activity 6497534
30 March 2018 Examination of Repairs · Drydock Exam · Hull Examination · Administrative Inspection
Physical examination · Sector North Carolina · USCG East District (CGD-E) · Activity 6381704
1 September 2017 Deficiency Check
Physical examination · Sector North Carolina · USCG East District (CGD-E) · Activity 6265686
6 July 2017 Type not recorded
No type recorded · Sector North Carolina · USCG East District (CGD-E) · Activity 6200877
21 April 2017 Annual Inspection · Administrative Inspection · Deficiency Check
Physical examination · Sector North Carolina · USCG East District (CGD-E) · Activity 6129496
11 April 2016 Deficiency Check · Drydock Exam · Internal Structural Exam · Hull Examination · COI Inspection
Physical examination · Sector North Carolina · USCG East District (CGD-E) · Activity 5851211
12 May 2014 Deficiency Check · Periodic Inspection · DAPI Audit
Physical examination · Sector North Carolina · USCG East District (CGD-E) · Activity 4856682
8 February 2012 Annual Inspection · Examination of Repairs · Internal Structural Exam · Hull Examination · Drydock Exam · Deficiency Check
Physical examination · Sector North Carolina · USCG East District (CGD-E) · Activity 4237685
8 April 2009 Deficiency Check · Annual Inspection
Physical examination · Marine Safety Unit Wilmington · USCG East District (CGD-E) · Activity 3448897
1 April 2008 Hull Examination · Annual Inspection
Physical examination · Marine Safety Unit Wilmington · USCG East District (CGD-E) · Activity 3175099
16 May 2007 Annual Inspection
Physical examination · Marine Safety Unit Wilmington · USCG East District (CGD-E) · Activity 2932246
11 April 2006 COI Inspection
Physical examination · Marine Safety Unit Wilmington · USCG East District (CGD-E) · Activity 2616524
30 March 2006 Hull Examination
Physical examination · Marine Safety Unit Wilmington · USCG East District (CGD-E) · Activity 2610506
21 April 2005 Annual Inspection
Physical examination · MSO WILMINGTON · USCG East District (CGD-E) · Activity 2332254
19 January 2005 Examination of Repairs
Physical examination · MSO WILMINGTON · USCG East District (CGD-E) · Activity 2277352
2 March 2004 Re-Inspection · Hull Examination
Physical examination · MSO WILMINGTON · USCG East District (CGD-E) · Activity 2009043
22 April 2003 Re-Inspection
Physical examination · MSO WILMINGTON · USCG East District (CGD-E) · Activity 1769542
6 November 2002 Deficiency Check
Physical examination · MSO WILMINGTON · USCG East District (CGD-E) · Activity 1701861
26 May 2002 Type not recorded
No type recorded · MSO WILMINGTON · USCG East District (CGD-E) · Activity 1625182
11 April 2002 Re-Inspection
Physical examination · MSO WILMINGTON · USCG East District (CGD-E) · Activity 1603515
14 January 2002 Hull Examination
Physical examination · MSO WILMINGTON · USCG East District (CGD-E) · Activity 1478491
6 November 2001 Administrative
Administrative · MSO WILMINGTON · USCG East District (CGD-E) · Activity 1075676
16 May 2001 Deficiency Check
Physical examination · MSO WILMINGTON · USCG East District (CGD-E) · Activity 1064180
17 April 2001 COI Inspection
Physical examination · MSO WILMINGTON · USCG East District (CGD-E) · Activity 1389353
15 May 2000 Re-Inspection
Physical examination · MSO WILMINGTON · USCG East District (CGD-E) · Activity 1386826
3 March 2000 Hull Examination
Physical examination · MSO WILMINGTON · USCG East District (CGD-E) · Activity 1446877
23 August 1999 Deficiency Check
Physical examination · MSO WILMINGTON · USCG East District (CGD-E) · Activity 778687
16 June 1999 Type not recorded
No type recorded · MSO WILMINGTON · USCG East District (CGD-E) · Activity 1388866
28 April 1999 Plan Review "T" Boat
Administrative · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 808123
23 April 1999 Deficiency Check · Re-Inspection
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1446789
16 October 1998 Hull Examination
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1447887
29 April 1998 COI Inspection
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1464109
11 December 1997 Type not recorded
No type recorded · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 668731
19 May 1997 Type not recorded
No type recorded · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1411567
19 May 1997 Re-Inspection
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1424453
26 September 1996 Hull Examination
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1433148
23 April 1996 Re-Inspection
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1430197
20 June 1995 Deficiency Check
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1187835
28 March 1995 COI Inspection
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 844938
6 September 1994 Type not recorded
No type recorded · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1174750
18 August 1994 Deficiency Check
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1173057
9 August 1994 Hull Examination
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1177053
13 June 1994 Re-Inspection
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1330955
6 May 1993 Re-Inspection
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 834329
14 August 1992 Hull Examination
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 962342
9 April 1992 COI Inspection · Deficiency Check
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 945782
16 September 1991 Administrative
Administrative · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1252140
12 June 1991 Deficiency Check
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1032491
9 May 1991 Re-Inspection
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1227046
19 September 1990 Deficiency Check
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1213201
8 August 1990 Hull Examination
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1210841
25 July 1990 Deficiency Check
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 907838
6 June 1990 Deficiency Check
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1236591
23 May 1990 Deficiency Check
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1226250
2 May 1990 Re-Inspection
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1222822
2 May 1989 COI Inspection
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1039162
7 February 1989 Hull Examination
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1350618
4 May 1988 Re-Inspection · Deficiency Check
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1202016
18 June 1987 Deficiency Check
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1312833
20 May 1987 Hull Examination · Re-Inspection
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1028003
29 May 1986 Deficiency Check
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 989860
8 May 1986 COI Inspection
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 989349
19 December 1985 Credit Drydock
Administrative · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 993567
30 April 1985 Type not recorded
No type recorded · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 980487

Deficiency record · 199

10 - Safety of Navigation › N/A - No Subsystem › Lights, shapes, sound-signals
Issued 14 May 2026 Resolved
Stbd running light not operating properly and needs replaced. Vessel is restricted to daytime operations and clear visibility. 46 CFR 183.429
Action required: 705 - Other - as specified
Resolved 18 May 2026
Resolution: STBD light replaced and tested
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 14 May 2026 Resolved
03 lifejackets found unserviceable. Vessel restricted to 73 total persons on limited coastwise route during warm weather months. 46 CFR 180.71
Action required: 705 - Other - as specified
Resolved 18 May 2026
Resolution: 03 lifejackets replaced with lights
10 - Safety of Navigation › N/A - No Subsystem › Charts
Issued 14 May 2026 Resolved
Paper navigation charts are wasted and need replaced. 46 CFR 184.420
Action required: 16 - Rectify deficiencies w/in 14 days
Due 28 May 2026
Resolved 15 May 2026
Resolution: New charts on board
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 14 May 2026 Resolved
Fire hose nozzle not the approved type. Replace with nozzle of good grad bronze or equivalent metal. 46 CFR 181.20-1
Action required: 16 - Rectify deficiencies w/in 14 days
Due 28 May 2026
Resolved 15 May 2026
Resolution: Installed approved nozzle
09 - Working and Living Conditions › 091 - Living Conditions › Medical Equipment
Issued 14 May 2026 Resolved
First-Aid kit needs to be in a suitable watertight container and clearly marked, and replace expired aspirin. 46 CFR 184.710
Action required: 16 - Rectify deficiencies w/in 14 days
Due 28 May 2026
Resolved 15 May 2026
Resolution: New watertight container and aspirin
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 14 May 2026 Resolved
Flexible hose coming off of air intake on port main engine is chaffed and worn. Replace with approved flex hose to satisfaction of the MI. 46 CFR 182.410(d)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 28 May 2026
Resolved 15 May 2026
Resolution: Replaced
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 30 March 2026 Resolved
Laz bilge alarm light not working. Repair to satisfaction of MI. 46 CFR 182.530(a)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 28 May 2026
Resolved 15 May 2026
Resolution: Bilge alarm light replaced and tested
18 - Maritime Labour Convention (Not Applicable to PSC Exams conducted in the U.S.) › N/A - No Subsystem › Other (Conditions of employment)
Issued 30 March 2026 Resolved
Employee Assistance Progam not posted. 46 CFR 16
Action required: 16 - Rectify deficiencies w/in 14 days
Due 28 May 2026
Resolved 18 May 2026
Resolution: EAP posted
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 13 May 2025 Resolved
Machinery and equipment installed on each vessel must be suitable for the vessel and its operation and for the purpose intended. All machinery and equipment must be installed and maintained in such a manner as to afford adequate protection from causing fire, explosion, machinery failure, and personnel injury. The starboard engine fuel strainers have broken free from mounts, are hanging loose and subject to the movement of the vessel. 46 CFR 182.100
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 16 May 2025
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 13 May 2025 Resolved
Exhaust gas must not leak from the piping or any connections. There are moderate exhaust fumes in the engine compartment when the engines are running. 46 CFR 182.430
Action required: 16 - Rectify deficiencies w/in 14 days
Due 27 May 2025
Resolved 16 May 2025
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 7 September 2024 Resolved
All machinery and equipment must be installed and maintained in such a manner as to afford adequate protection from causing fire, explosion, machinery failure, and personnel injury; vessel reported a loss of propulsion on STBD side MDE. 46 CFR 182.100
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 11 September 2024
Resolved 11 September 2024
08 - Alarms › N/A - No Subsystem › Other (alarms)
Issued 30 May 2024 Resolved
A visual and audible alarm must be provided at the operating station to indicate high water level in the bilges, the lazarette and engine compartment bilge alarms do not work. 46 CFR 182.530
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 30 May 2024
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 30 May 2024 Resolved
A life jacket must be provided for each person the vessel is authorized to carry; three (3) child size jackets were condemned leaving seven (7) viable child life jackets. The vessel is restricted to a maximum of seven (7) children until additional life jackets are provided. 46 CFR 180.71
Action required: 16 - Rectify deficiencies w/in 14 days
Due 27 June 2024
Resolved 13 May 2025
11 - Life Saving Appliances › N/A - No Subsystem › Other (life saving)
Issued 30 May 2024 Resolved
The name of the vessel must be clearly and legibly marked on the life float paddles; the markings are faded and not legible. 46 CFR 185.604
Action required: 16 - Rectify deficiencies w/in 14 days
Due 13 June 2024
Resolved 12 June 2024
11 - Life Saving Appliances › N/A - No Subsystem › Other (life saving)
Issued 30 May 2024 Resolved
Each life jacket must be marked with Type I reflective material approved in 46 CFR 164.018; a number of life jackets have deteriorated reflective material. 46 CFR 185.604 (h)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 13 June 2024
Resolved 12 June 2024
11 - Life Saving Appliances › N/A - No Subsystem › Other (life saving)
Issued 30 May 2024 Resolved
The name of the vessel must be clearly and legibly marked on each life buoy; the letters on the existing life buoy are peeling off. 46 CFR 185.604
Action required: 16 - Rectify deficiencies w/in 14 days
Due 13 June 2024
Resolved 12 June 2024
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 1 May 2023 Resolved
A vessel must be provided with a satisfactory arrangement for draining any watertight compartment, other than small buoyancy compartments, under all practicable conditions; vessel's fixed bilge pump was unable reliably hold suction
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 2 May 2023
Resolution: Owner replaced flexible discharge hose off pump which was restricted due to collapse.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 1 May 2023 Resolved
Electrical equipment on a vessel must be installed and maintained to Protect passengers, crew, other persons, and the vessel from electrical hazards, including fire, caused by or originating in electrical equipment, and electrical shock; Replace receptacle on fwd bulkhead of ER due to cracking related heat.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 15 May 2023
Resolved 4 May 2023
Resolution: Receptacle removed
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 1 May 2023 Resolved
electrical equipment on a vessel must be installed and maintained to Protect passengers, crew, other persons, and the vessel from electrical hazards, including fire, caused by or originating in electrical equipment, and electrical shock; Remount battery switch in Aft ER. Switch is laying in bilge.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 15 May 2023
Resolved 4 May 2023
Resolution: Switch mounted to aft bulkhead
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 1 May 2023 Resolved
Electrical equipment on a vessel must be installed and maintained to Protect passengers, crew, other persons, and the vessel from electrical hazards, including fire, caused by or originating in electrical equipment, and electrical shock; Remove or replace broke light hanging from STBD exterior of bridge.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 15 May 2023
Resolved 4 May 2023
Resolution: Light removed
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 1 May 2023 Resolved
Electrical equipment on a vessel must be installed and maintained to Protect passengers, crew, other persons, and the vessel from electrical hazards, including fire, caused by or originating in electrical equipment, and electrical shock; properly connect marine romex wire to junction box on light between engines.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 15 May 2023
Resolved 4 May 2023
Resolution: Proper stuffing tube added
09 - Working and Living Conditions › 092 - Working Conditions › Other (accident prevention)
Issued 1 May 2023 Resolved
All escape hatches and other emergency exits used as means of escape must be marked on both sides in clearly legible letters at least 50 millimeters (2 inches) high: “EMERGENCY EXIT, KEEP CLEAR”,ER escape is not labeled.
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Due 15 May 2023
Resolved 4 May 2023
Resolution: Hatch labeled w/ sharpie
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 15 September 2022 Resolved
Propulsion machinery must be suitable in type and design for propulsion requirements of the hull in which it is installed and capable of operating at constant marine load under such requirements without exceeding its designed limitations; vessel experienced unexpected shutdown of Port engine while under way w/ pax.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 16 September 2022
Resolution: Part replaced and engine test sat.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 7 June 2022 Resolved
46CFR180.71- A life jacket approved under 160.002, 005, or 055 must be carried onboard for each person; 11 Adult and 01 Child size life jacket has been condemned; vessel is restricted to 64 adult pax.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 21 June 2022
Resolved 9 June 2022
Resolution: Received photgraphic evidence of new lifejackets
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 13 June 2021 Resolved
Propulsion machinery must be suitable in type and design for propulsion requirements of the hull in which it is installed and capable of operating at constant marine load under such requirements without exceeding its designed limitations; vessel experienced unexpected shutdown of Port engine while under way w/ pax.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 15 June 2021
Resolution: Blower coupling was replaced and vessel was sea trialed sat.
10 - Safety of Navigation › N/A - No Subsystem › Nautical publications
Issued 29 April 2021 Resolved
A vessel must carry adequate and up-to-date navigation publications for the intended route; the Coast Pilot, CG Light List and Notice to Mariners are outdated.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 9 June 2021
10 - Safety of Navigation › N/A - No Subsystem › Lights, shapes, sound-signals
Issued 29 April 2021 Resolved
A vessel must have navigation lights that are in compliance with the International and Inland Navigation Rules; the all around white light is not operational.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 9 June 2021
11 - Life Saving Appliances › N/A - No Subsystem › Buoyant apparatus
Issued 29 April 2021 Resolved
The means of attaching the float free link to the life float must have the breaking strength of at least that of the float free link, if synthetic, be of a dark color and resistant to UV light; the sea painter is deteriorated on one of the life floats.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 9 June 2021
11 - Life Saving Appliances › N/A - No Subsystem › Buoyant apparatus
Issued 29 April 2021 Resolved
Each life float must be equipped with a floating water light certified to meet 160.010; one of the water lights is broken.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 9 June 2021
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 29 April 2021 Resolved
Electrical equipment must be installed and maintained to protect personnel and the vessel from electrical hazards; there are unprotected dead end wires in the engine compartment.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 9 June 2021
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 11 August 2020 Resolved
Where flexible non-metallic hose is permitted, it must meet the required specs for its intended use; STBD side fuel supply hose off Racor filter is in disrepair and in need of replacement.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 25 August 2020
Resolved 18 August 2020
Resolution: Cropped out bad section of hose and installed new fitting.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Manholes/flush scuttles
Issued 11 August 2020 Resolved
A hatch exposed to the weather must be watertight; flush mounted scuttle leading to engineroom has a bad gasket and is not watertight.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 25 August 2020
Resolved 25 August 2020
Resolution: Cleaned out hatch cover and reinstalled gasket with sealant.
07 - Fire Safety › N/A - No Subsystem › Fire pumps and its pipes
Issued 11 August 2020 Resolved
Fire main discharge valve off pump is seized in open position.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 25 August 2020
Resolved 18 August 2020
Resolution: Renewed the valve.
09 - Working and Living Conditions › 092 - Working Conditions › Holds and tanks safety
Issued 11 August 2020 Resolved
The MI shall examine the bilges to see that there is no accumulation of matter which might create fire hazard; fuel tank space has sewage accumulation from valve misalignment.
Condition: Design Flaw
Action required: 701 - Prior to carriage of passengers/cargo
Due 11 August 2020
Resolved 11 August 2020
Resolution: Operator pumped space to shore and cleaned.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 11 August 2020 Resolved
The vessel must be provided w/ a satisfactory arrangement for draining any watertight compartment; bilge suction valve is corroded and not usable.
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Due 11 August 2020
Resolved 11 August 2020
Resolution: Crew applied liquid penetrant and freed valve prior to completing the inspection
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 19 July 2020 Resolved
Propulsion machinery must be suitable in type and design for propulsion requirements of the hull in which it is installed and capable of operating at constant marine load under such requirements without exceeding its designed limitations. Vsl experienced loss of propulsion in the port main engine. Repair and conduct sea trials to prove proper operation to satisfaction of attending marine inspector prior to carrying passengers.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 20 July 2020
Resolution: Attended vessel moored Carolina Beach. Witnessed satisfactory test of both main engines.
09 - Working and Living Conditions › 092 - Working Conditions › Machinery
Issued 30 July 2019 Resolved
Numerous hose connections within the engine compartment do not have two hose clamps as required; install a second hose clamp as follows, (2) through hull connections stbd side fwd, (1) through hull for wash down pump, (1) on the port main engine exhaust system.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 13 August 2019
07 - Fire Safety › N/A - No Subsystem › Remote Means of control (opening,pumps,ventilation,etc.) Machinery spaces
Issued 30 July 2019 Resolved
The remote shutoff valves for the fuel system are not labeled, properly mark the valves "Fuel Shutoff".
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 13 August 2019
09 - Working and Living Conditions › 092 - Working Conditions › Machinery
Issued 30 July 2019 Resolved
The valve handle for the wash down pump raw water intake is broken; permanently affix a combination wrench to the valve until next haul out.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 13 August 2019
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 30 July 2019 Resolved
Repair or replace the broken light in the passenger accommodation space.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 13 August 2019
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Auxiliary engine
Issued 30 July 2019 Resolved
The generator is not operational due to defective solenoid; repair the generator as needed.
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 13 August 2019
04 - Emergency Systems › N/A - No Subsystem › Public address system
Issued 1 August 2018 Resolved
The vessel has a megaphone in lieu of a PA system, however it does not work; provide the vessel with a suitable PA system or megaphone.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 1 August 2018
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 1 August 2018 Resolved
The stbd main engine raw water intake hose is missing two hose clamps; install hose clamps where needed.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 1 August 2018
Navigation › Collision/Grounding Avoidance › Navigation Lights
Issued 21 April 2017 Resolved
Repair the stern light due to failure.
Due 20 May 2017
Resolved 5 May 2017
Engineering › Lubricating Oil Service System › Gauge
Issued 21 April 2017 Resolved
Repair or replace the lube oil pressure gauge for the port main engine.
Due 20 May 2017
Resolved 5 May 2017
Engineering › Diesel Engine (auxiliary) › Piping (exhaust)
Issued 21 April 2017 Resolved
Install an additional hose clamp on the exhaust hose to the generator IWO the bhd penetration.
Due 20 May 2017
Resolved 5 May 2017
Electrical › Electric Supply System (service) › Battery Conductor
Issued 21 April 2017 Resolved
Remove excessive wire connections from the generator battery and install a terminal bus bar.
Due 20 May 2017
Resolved 5 May 2017
Engineering › Bilge Water Management System › Strainer
Issued 21 April 2017 Resolved
Clean the bilge suction strainer in the fuel tank compartment due to blockage.
Due 20 May 2017
Resolved 5 May 2017
Engineering › Diesel Engine (auxiliary) › Piping (exhaust)
Issued 21 April 2017 Resolved
The generator exhaust hose is chaffing on the side stringers in the steering compartment; install chaffing gear as needed.
Due 20 May 2017
Resolved 1 September 2017
Engineering › Steering Gear System › Piping
Issued 21 April 2017 Resolved
Repair the hydraulic fluid leak in the steering compartment.
Due 20 May 2017
Resolved 5 May 2017
Electrical › Electric Supply System (service) › Overcurrent Device
Issued 21 April 2017 Resolved
Provide overcurrent protection for the conductors on the stbd battery in the engine compartment.
Due 20 May 2017
Resolved 5 May 2017
Electrical › Electric Supply System (service) › Cable
Issued 21 April 2017 Resolved
Replace the deteriorated conductor on the stbd bus bar in the engine compartment.
Due 20 May 2017
Resolved 5 May 2017
Electrical › Electric Supply System (service) › Cable
Issued 21 April 2017 Resolved
Replace the deteriorated conductor on the generator battery.
Due 20 May 2017
Resolved 5 May 2017
Electrical › Electrical Distribution System (service) › Wiring
Issued 21 April 2017 Resolved
Remove wire nuts and install butt connectors in wiring on the port side of the engine compartment.
Due 20 May 2017
Resolved 5 May 2017
Electrical › Electrical Distribution System (service) › Wiring
Issued 21 April 2017 Resolved
Properly terminate the dead end wires in the engine compartment, port side forward.
Due 20 May 2017
Resolved 5 May 2017
Electrical › Electric Supply System (service) › Cable
Issued 21 April 2017 Resolved
Replace the deteriorated conductor on the port battery in the engine compartment.
Due 20 May 2017
Resolved 5 May 2017
Stability › Watertight Integrity › General
Issued 21 April 2017 Resolved
Reinstall the captive chain for the aft hatch cover.
Due 20 May 2017
Resolved 5 May 2017
Stability › Watertight Integrity › General
Issued 21 April 2017 Resolved
Properly seal the through hull fitting on the stbd side in the forward void.
Due 20 May 2017
Resolved 5 May 2017
Lifesaving › Lifefloat › Serviceable
Issued 18 May 2016 Resolved
Repaint and seal holes on lifefloats as needed.
Due 2 June 2016
Resolved 3 June 2016
Lifesaving › Lifefloat › Painter
Issued 18 May 2016 Resolved
Ensure all lifefloat sea painters are 100 ft.
Due 2 June 2016
Resolved 3 June 2016
Electrical › Electric Supply System (service) › Cable
Issued 18 May 2016 Resolved
On newly replaced electrical box in engine room-install backing nuts for wire knockouts.
Due 18 June 2016
Resolved 3 June 2016
Electrical › Electrical Distribution System (service) › Wiring
Issued 18 May 2016 Resolved
Replace wire nuts in lazarette - fresh water pump and #1 void - bilge pump, with crimp connectors or locate inside a junction box with electrical tape overwrap.
Due 18 June 2016
Resolved 3 June 2016
Communications › Radio Communications › VHF Radiotelephone
Issued 18 May 2016 Resolved
Connect GPS to VHF radio and input MMSI number, show proper operation.
Due 18 June 2016
Resolved 21 April 2017
Electrical › Electric Supply System (service) › Battery Installation
Issued 18 May 2016 Resolved
Replace 01 battery on STBD battery bank, rewire conductors ensuring no greater than 4 connected to any 1 terminal.
Due 18 June 2016
Resolved 3 June 2016
Stability › Watertight Integrity › Watertight Subdivision Standard
Issued 18 May 2016 Resolved
Make appropriate repairs to engine room hatch. Prove watertight seal.
Due 18 June 2016
Resolved 3 June 2016
Documentation › Certificates/Documents › FCC Safety Radiotelephony Certificate
Issued 12 May 2014 Resolved
The existing FCC Safety Radio Certificate has expired, provide proof of new certificate.
Due 11 June 2014
Resolved 13 May 2014
Documentation › Logs/Records › Drug Test Records
Issued 12 May 2014 Resolved
The existing drug program contract has expired; provide proof of a new contract.
Due 11 June 2014
Resolved 13 May 2014
Resolution: Received a copy of current contract via email.
Accommodation/Occupational Safety › Medical/First Aid › Medicine Chest
Issued 12 May 2014 Resolved
Replace all expired items in the first aid kit.
Due 11 June 2014
Resolved 9 June 2014
Navigation › Collision/Grounding Avoidance › Navigation Bridge Visibility
Issued 12 May 2014 Resolved
The existing plexiglas windows have reduced visibility due to aging; replace the port and stbd pilothouse windows.
Due 11 July 2014
Resolved 19 July 2014
Navigation › Collision/Grounding Avoidance › Navigation Lights
Issued 12 May 2014 Resolved
Replace the stbd running light bulb due to an improper intensity.
Due 11 June 2014
Resolved 9 June 2014
Lifesaving › Lifebuoys › Buoyant Lifeline
Issued 12 May 2014 Resolved
Replace the lifeline on the ring buoy due to deterioration.
Due 11 June 2014
Resolved 9 June 2014
Lifesaving › Lifebuoys › Self-igniting Lights
Issued 12 May 2014 Resolved
Replace the line for the water light on the ring buoy due to deterioration.
Due 11 June 2014
Resolved 9 June 2014
Fire Fighting › Nozzles › Condition
Issued 12 May 2014 Resolved
Replace the fire hose nozzle due to deterioration.
Due 11 June 2014
Resolved 9 June 2014
Electrical › Electric Supply System (service) › Cable
Issued 12 May 2014 Resolved
Properly affix the main generator cable to prevent chaffing on the engine room light fixture.
Due 11 June 2014
Resolved 9 June 2014
Engineering › Fuel Oil Service System › Piping
Issued 12 May 2014 Resolved
The fuel hoses and fittings, used in lieu of piping, are not of an approved type. Replace the lines with piping or hoses and fittings of an approved type. (SAE J1942 hose and SAE J1475 fittings)
Due 11 August 2014
Resolved 19 June 2014
Engineering › Fuel Oil Service System › Hose
Issued 12 May 2014 Resolved
The fuel hose penetrates the forward engine room bulkhead without the use of metallic fitting; provide metallic bulkhead penetrations for the fuel lines or replace with piping.
Due 11 August 2014
Resolved 19 June 2014
Electrical › Electrical Distribution System (service) › Wiring
Issued 8 February 2012 Resolved
Properly terminate or remove all dead end wires throughout the vessel.
Due 4 May 2012
Resolved 3 May 2012
Engineering › Diesel Engine (auxiliary) › Piping (exhaust)
Issued 8 February 2012 Resolved
Replace the deteriorated hose on the generator exhaust line to the resonator.
Due 4 May 2012
Resolved 3 May 2012
Communications › Alarms/Indicators › Bilge Alarm
Issued 8 February 2012 Resolved
Properly mount the bilge alarm float switch in the lazarette.
Due 4 May 2012
Resolved 3 May 2012
Engineering › Steering Gear System › Rudder Stock
Issued 8 February 2012 Resolved
Re-pack port rudder due to leak.
Due 4 May 2012
Resolved 3 May 2012
Engineering › Diesel Engine (propulsion-reduction gear) › Seal
Issued 8 February 2012 Resolved
Repair the oil leak on the stbd main engine IWO hose fitting on the outboard side.
Due 4 May 2012
Resolved 3 May 2012
Navigation › Piloting/Steering › Gyro Compass
Issued 8 April 2009 Resolved
Compass light is not operational. Make necessary repairs.
Condition: Unknown
Action required: 705 - Other - as specified
Due 7 May 2009
Resolved 1 July 2009
Resolution: Repairs made to Compass light.
Communications › Audible Communications › Bell
Issued 8 April 2009 Resolved
Provide vessel with an appropriate sized Bell (7.9 inch)
Condition: Unknown
Action required: 705 - Other - as specified
Due 7 May 2009
Resolved 1 July 2009
Resolution: Appropriate sized Bell (7.9 inch) provided.
Engineering › Fuel Oil Storage/Transfer System › Ventilation
Issued 8 April 2009 Resolved
Replace the Fuel Vent Flame Screens with screens having the correct mesh (30 X 30).
Condition: Unknown
Action required: 701 - Prior to carriage of passengers/cargo
Due 7 May 2009
Resolved 1 July 2009
Resolution: Fuel Vent Flame Screens replaced with screens having the correct mesh (30 X 30).
Construction/Loadline › Structures › End Bulkhead
Issued 1 April 2008 Resolved
Fractured in the forward peak bulkhead on starboard side of the vessel.
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Due 18 April 2008
Resolved 30 April 2008
Electrical › Electrical Distribution System (service) › Wiring
Issued 16 May 2007 Resolved
Remove Dead End wiring in engine room
Action required: 705 - Other - as specified
Due 4 June 2007
Resolved 16 May 2007
Resolution: All dead end wiring removed from engine room.
Fire Fighting › Portable CO2 Fire Extinguisher › Mounting Bracket
Issued 16 May 2007 Resolved
Repair/Replace rusted mounting bracket for CO2 extinguisher in Galley Area.
Action required: 705 - Other - as specified
Due 4 June 2007
Resolved 17 May 2007
Resolution: Fire Extinguisher bracket repaired to satisfaction of attending CG Inspector
Construction/Loadline › Structures › Scuttle
Issued 16 May 2007 Resolved
Deck Scuttle covers on forward and aft lazerette spaces require lanyards.
Action required: 705 - Other - as specified
Due 4 June 2007
Resolved 16 May 2007
Resolution: All scuttles have lanyards attached
Lifesaving › Launching Appliances › Release Mechanism
Issued 11 April 2006 Resolved
Hydrostatic release not installed on EPIRB. Owner had removed out of date release and has ordered a replacement. Issued 835 for no sail until deficiency has been cleared by USCG Inspector.
Condition: Unknown
Action required: 705 - Other - as specified
Due 18 April 2006
Resolved 14 April 2006
Resolution: Owner provided receipt for new hydrostatic release which has been installed.
Fire Fighting › Portable Dry Chemical Fire Extinguisher › Mounting Bracket
Issued 11 April 2006 Resolved
Portable extinguisher for engine room not secured by mounting bracket.
Condition: Unknown
Action required: 705 - Other - as specified
Due 18 April 2006
Resolved 12 April 2006
Resolution: Corrected
Electrical › Electric Supply System (service) › Battery Installation
Issued 11 April 2006 Resolved
Vessel's main battery box missing cover.
Condition: Unknown
Action required: 705 - Other - as specified
Due 18 April 2006
Resolved 1 May 2006
Resolution: Corrected
Electrical › Electrical Distribution System (service) › Wiring
Issued 11 April 2006 Resolved
Wiring for bilge pump in #2 hold installed with wire nuts. Instructed owner to remove wire nuts and provide proper connection in watertight junction box.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 18 April 2006
Resolved 1 May 2006
Resolution: Corrected
Construction/Loadline › Hull › Stiffener
Issued 11 April 2006 Resolved
Main deck support/overhead beam in #2 hold had fallen into bilge due to fastener corrosion.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 18 April 2006
Resolved 19 April 2006
Resolution: Corrected
Engineering › Bilge Water Management System › Pump
Issued 11 April 2006 Resolved
Installed bilge pump inoperable due to impeller failure.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 18 April 2006
Resolved 11 April 2006
Resolution: Corrected on site prior to completion of inspection.
Lifesaving › Lifejacket/PFD (General) › Retroreflective Material
Issued 21 April 2005 Resolved
RENEW RETRO TAPE ON THE 24 ADULT AND 2 CHILD PFDs REQUIRING IT. CLEARED.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 21 April 2005
Fire Fighting › Portable Dry Chemical Fire Extinguisher › Service
Issued 21 April 2005 Resolved
SHOW PROOF OF 6 YEAR SERVICING ON THE 2 B-II EXTINGUISHERS OR RENEW. NO PASSENGERS FOR HIRE UNTIL CLEARED.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 21 April 2005
Personnel › Training › First Aid/CPR
Issued 2 March 2004 Resolved
SIGHTED CPR AND FIRST AID TRAINING CARDS
Condition: Unknown
Due 24 March 2004
Resolved 24 March 2004
Resolution: SIGHTED CPR AND FIRST AID CARDS
Fire Fighting › Portable Dry Chemical Fire Extinguisher › Condition
Issued 2 March 2004 Resolved
COMPLETE INSPECTION ON ONE PORTABLE FIRE EXTINGUISHER.
Condition: Improper/Lack of Maintenance
Due 24 March 2004
Resolved 24 March 2004
Resolution: CLEARED
Engineering
Issued 14 January 2002 Resolved
Prove proper operation of through hull 1 1/2 inch fire pump suction gate valve. LEGACY COMPONENT DESC: Through hull gate valve
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 7 November 2002
Resolved 7 November 2002
Construction/Loadline › Structures
Issued 14 January 2002 Resolved
Properly secure engine compartment covers on main deck LEGACY COMPONENT DESC: Machinery Space Opening
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 7 November 2002
Unknown
Issued 17 April 2001 Resolved
Provide lifesaving equipment maintenance records.
Condition: Unknown
Due 17 April 2001
Resolved 17 April 2001
Navigation
Issued 17 April 2001 Resolved
Prove proper operation of stern light prior to night ops.
Condition: Unknown
Due 17 April 2001
Resolved 17 April 2001
Unknown
Issued 17 April 2001 Resolved
Provide crew training log book.
Condition: Unknown
Due 17 April 2001
Resolved 17 April 2001
Lifesaving
Issued 17 April 2001 Resolved
Properly mark all life jacket stowage lockers.
Condition: Unknown
Due 17 April 2001
Resolved 17 April 2001
Lifesaving
Issued 17 April 2001 Resolved
Provide life jacket donning instructions. post in area of life jacket stowage lockers.
Condition: Unknown
Due 17 April 2001
Resolved 17 April 2001
Electrical
Issued 16 June 1999 Resolved
REMOUNT LIGHT IN PORT HEAD.
Condition: Unknown
Due 16 June 1999
Resolved 16 June 1999
Documentation
Issued 16 June 1999 Resolved
RE-REGISTER FCC STATION LICENSE.
Condition: Unknown
Due 29 July 1999
Resolved 29 July 1999
Lifesaving
Issued 16 June 1999 Resolved
REMARK ALL LIFESAVING EQUIPMENT WITH NEW VESSEL NAME.
Condition: Unknown
Due 29 July 1999
Resolved 29 July 1999
Lifesaving
Issued 16 June 1999 Resolved
PROVIDE ONE ADDITIONAL FLOAT LIGHT.
Condition: Unknown
Due 29 July 1999
Resolved 29 July 1999
Lifesaving
Issued 16 June 1999 Resolved
PROVIDE LEGIBLE EMERGENCY CHECKOFF LIST.
Condition: Unknown
Due 29 July 1999
Resolved 29 July 1999
Lifesaving
Issued 16 June 1999 Resolved
EXAMINE AND REPAIR OR REPLACE AS NECESSARY EACH PFD.
Condition: Unknown
Due 29 July 1999
Resolved 29 July 1999
Navigation
Issued 16 June 1999 Resolved
REMOUNT OR REPLACE HYDRAULIC JUNCTION BLOCK IN STEERING SPACE, AND RENEW MOUNTING BOARD.
Condition: Unknown
Due 29 July 1999
Resolved 29 July 1999
Accommodation/Occupational Safety
Issued 16 June 1999 Resolved
REMOVE UNUSED OR OBSOLETE PIPING AND WIRING RUNS THROUGHOUT THE VESSEL.
Condition: Unknown
Due 16 June 1999
Resolved 16 June 1999
Construction/Loadline
Issued 16 June 1999 Resolved
CLEAN AND DRY OUT ALL INTERNAL COMPARTMENTS FOR FURTHER EXAMINATION.
Condition: Unknown
Due 29 July 1999
Resolved 29 July 1999
Electrical
Issued 16 June 1999 Resolved
ENSURE PROPER ELECTRICAL CONNECTIONS THROUGHOUT THE VESSEL.
Condition: Unknown
Due 16 June 1999
Resolved 16 June 1999
Construction/Loadline
Issued 16 June 1999 Resolved
REPLACE BASE BLOCKS FOR ENGINE ROOM STANCHIONS.
Condition: Unknown
Due 29 July 1999
Resolved 29 July 1999
Construction/Loadline
Issued 16 June 1999 Resolved
TIGHTEN ALL THROUGH HULL FITTINGS TO STOP LEAKAGE.
Condition: Unknown
Due 29 July 1999
Resolved 29 July 1999
Construction/Loadline
Issued 16 June 1999 Resolved
POSITIVELY IDENTIFY EACH BILGE SYSTEM VALVE IN THE ENGINE ROOM.
Condition: Unknown
Due 16 June 1999
Resolved 16 June 1999
Construction/Loadline
Issued 16 June 1999 Resolved
PROVIDE CAPTIVE CHAINS OR CABLES FOR EACH UNHINGED FLUSHH DECK HATCH.
Condition: Unknown
Due 16 June 1999
Resolved 16 June 1999
Construction/Loadline
Issued 16 June 1999 Resolved
REPAIR OR REPLACE FRAMING AROUND STBD HEAD DOOR.
Condition: Unknown
Due 16 June 1999
Resolved 16 June 1999
Construction/Loadline
Issued 16 June 1999 Resolved
PROVIDE STRAINERS OR SCREENS BILGE PIPING IN ALL COMPARTMENTS.
Condition: Unknown
Due 29 July 1999
Resolved 29 July 1999
Engineering
Issued 16 June 1999 Resolved
REALIGN EMERGENCY FUEL SHUTOFF HANDLES TO ALLOW CLOSING OF BOTH VALVES.
Condition: Unknown
Due 16 June 1999
Resolved 16 June 1999
Electrical
Issued 16 June 1999 Resolved
PROPERLY REMOUNT EXTERIOR SPOTLIGHTS ON CABIN.
Condition: Unknown
Due 16 June 1999
Resolved 16 June 1999
Navigation
Issued 16 June 1999 Resolved
PROVIDE CURRENT COPIES OF SUBCHAPTER "T" REGULATIONS AND NAVIGATION RULES BOOKLET.
Condition: Unknown
Due 29 July 1999
Resolved 29 July 1999
Electrical
Issued 16 June 1999 Resolved
PROVIDE COVER FOR "NIGHTLIGHT" OUTLET IN PILOTHOUSE.
Condition: Unknown
Due 29 July 1999
Resolved 29 July 1999
Lifesaving
Issued 16 June 1999 Resolved
PROPERLY REGISTER EPIRB WITH NOAA; MARK HYDRO RELEASE EXPIRATION DATE ON EPIRB HOLDER; REMOVE OLD CLASS A EPIRB FROM VESSEL.
Condition: Unknown
Due 29 July 1999
Resolved 29 July 1999
Engineering
Issued 16 June 1999 Resolved
PROVIDE PROPER HANGERS FOR STBD EXHAUST IN STEERING SPACE.
Condition: Unknown
Due 29 July 1999
Resolved 29 July 1999
Navigation
Issued 16 June 1999 Resolved
TIGHTEN OR REPACK PORT RUDDERPOST.
Condition: Unknown
Due 16 June 1999
Resolved 16 June 1999
Electrical
Issued 16 June 1999 Resolved
CLEAR OUT DEAD-END CABLES UNDER PILOTHOUSE CONSOLE.
Condition: Unknown
Due 16 June 1999
Resolved 16 June 1999
Construction/Loadline
Issued 16 June 1999 Resolved
PROVIDE LONG TERM PLANS FOR EXAMINATION AND RENEWAL OF WINDOWS, INTERIOR BULKHEADS FRAMES AND FORMICA SHEETS.
Condition: Unknown
Due 16 June 1999
Resolved 16 June 1999
Engineering
Issued 16 June 1999 Resolved
REMOVE IMPROPER PATCH AND PROPERLY REPAIR STBD INBOARD EXHAUST PIPING IN STEERING SPACE.
Condition: Unknown
Due 16 June 1999
Resolved 16 June 1999
Accommodation/Occupational Safety
Issued 16 June 1999 Resolved
PROVIDE PLAN FOR INCREASED VENTILATION IN THE STEERING SPACE.
Condition: Unknown
Due 16 June 1999
Resolved 16 June 1999
Lifesaving
Issued 23 April 1999 Resolved
INSTALL 100' PAINTER W/SUITABLE FLOAT FREE LINK TO ALL LIFEFLOATS._x001C_ _x001C_ _x001C_ _x001C_
Condition: Unknown
Due 7 May 1999
Resolved 29 June 1999
Fire Fighting
Issued 23 April 1999 Resolved
COMPLETE INSTALLATION OF AND PROVE OPERATION OF ENGINE ROOM FIRE SUPRESSIONSYSTEM._x001C_ _x001C_ _x001C_
Condition: Unknown
Due 7 May 1999
Resolved 29 June 1999
Electrical
Issued 23 April 1999 Resolved
INSTALL TOPS ON BATTERY BOXES._x001C_ _x001C_ _x001C_ _x001C_
Condition: Unknown
Due 7 May 1999
Resolved 29 June 1999
Electrical
Issued 23 April 1999 Resolved
BETTER SUPPORT ENGINE WIRING AND SENDING UNITS._x001C_ _x001C_ _x001C_ _x001C_
Condition: Unknown
Due 7 May 1999
Resolved 29 June 1999
Electrical
Issued 23 April 1999 Resolved
REPAIR WATER LEAK ON GENERATOR._x001C_ _x001C_ _x001C_ _x001C_
Condition: Unknown
Due 7 May 1999
Resolved 29 June 1999
Construction/Loadline
Issued 23 April 1999 Resolved
INSTALL MEANS OF MAKING ENGINE HATCHES WATER TIGHT._x001C_ _x001C_ _x001C_ _x001C_
Condition: Unknown
Due 7 May 1999
Resolved 29 June 1999
Accommodation/Occupational Safety
Issued 23 April 1999 Resolved
RENEW ROTTED AREA OF DOOR FRAMES P/S ON CABIN._x001C_ _x001C_ _x001C_ _x001C_
Condition: Unknown
Due 7 May 1999
Resolved 29 June 1999
Construction/Loadline
Issued 23 April 1999 Resolved
INSTALL HIGH WATER ALARMS IN ENGINE ROOM, LAZERETTE AND MIDDLE COMPARTMENT._x001C_ _x001C_ _x001C_
Condition: Unknown
Due 7 May 1999
Resolved 29 June 1999
Construction/Loadline
Issued 16 October 1998 Resolved
CONDUCT CREDIT DRYDOCK EXAM. HULL INSPECTION IS 3 WEEKS OVERDUE. LAST DRYDOCK WAS ON 26SEP96.
Condition: Unknown
Due 8 January 1999
Resolved 8 January 1999
Documentation
Issued 19 May 1997 Resolved
FAILURE TO PAY USER FEE DURING THE PERIOD OF 01MAY95 TO 30APR96._x001C_ _x001C_ _x001C_ _x001C_
Condition: Unknown
Due 12 December 1997
Resolved 12 December 1997
Engineering
Issued 28 March 1995 Resolved
Double clamp raw water suction hose to port engine.
Condition: Unknown
Due 28 March 1995
Resolved 28 March 1995
Documentation
Issued 28 March 1995 Resolved
Provide and post stability letter.
Condition: Unknown
Due 28 March 1995
Resolved 28 March 1995
Fire Fighting
Issued 28 March 1995 Resolved
Provide onboard hand fire and bilge pump.
Condition: Unknown
Due 28 March 1995
Resolved 28 March 1995
Engineering
Issued 28 March 1995 Resolved
Adjust shaft packing on port and starboard shafts.
Condition: Unknown
Due 28 March 1995
Resolved 28 March 1995
Fire Fighting
Issued 28 March 1995 Resolved
Provide and install metallic nozzle on fire hose.
Condition: Unknown
Due 28 March 1995
Resolved 28 March 1995
Construction/Loadline
Issued 9 August 1994 Resolved
Renew approximately 4' x 2' of main deck on port side.
Condition: Unknown
Due 9 August 1994
Resolved 9 August 1994
Construction/Loadline
Issued 9 August 1994 Resolved
Scrape/treat rot at engineroom hatch.
Condition: Unknown
Due 9 August 1994
Resolved 9 August 1994
Engineering
Issued 9 August 1994 Resolved
Repair port engineroom vent trunk.
Condition: Unknown
Due 9 August 1994
Resolved 9 August 1994
Navigation
Issued 9 April 1992 Resolved
Replace lens on starboard sidelight.
Condition: Unknown
Due 19 May 1992
Resolved 19 May 1992
Engineering
Issued 9 April 1992 Resolved
Modify fuel shut-off valves so they are operable from outside the fuel tankcompartment.
Condition: Unknown
Due 19 May 1992
Resolved 19 May 1992
Lifesaving
Issued 9 April 1992 Resolved
Provide receipt for EPIRB. If manufactured before 01OCT88. Replace with newer Class "A" or category 1 (406MHZ)
Condition: Unknown
Due 19 May 1992
Resolved 19 May 1992
Navigation
Issued 9 April 1992 Resolved
Repair SSB radio.
Condition: Unknown
Due 19 May 1992
Resolved 19 May 1992
Lifesaving
Issued 9 May 1991 Resolved
PROVIDE 4 ADDITIONAL ADULT LIFEJACKETS & 1 CHILD LIFEJACKET. VESSEL LIMITED TO NO MORE THAN 70 TOTAL PERSONS UNTIL COMPLETE.
Condition: Unknown
Due 9 May 1991
Resolved 9 May 1991
Navigation
Issued 9 May 1991 Resolved
PROPERLY INSTALL & SECURE STERN LIGHT.
Condition: Unknown
Due 9 May 1991
Resolved 9 May 1991
Navigation
Issued 9 May 1991 Resolved
RENEW BATTERY IN EPIRB PRIOR TO OPERATING BEYOND 20 MILES FROM A HARBOR OF SAFE REFUGE AND NO LATER THAN 16MAY91.
Condition: Unknown
Due 9 May 1991
Resolved 9 May 1991
Lifesaving
Issued 9 May 1991 Resolved
RENEW ALL EXPIRED PFD LIGHTS PRIOR TO OPERATING BEYOND 20 MILES FROM A HARBOR OF SAFE REFUGE AND NO LATER THAN 16MAY91.
Condition: Unknown
Due 9 May 1991
Resolved 9 May 1991
Documentation
Issued 9 May 1991 Resolved
POST EMER. CHECKOFF LIST IN WHEELHOUSE.
Condition: Unknown
Due 9 May 1991
Resolved 9 May 1991
Construction/Loadline
Issued 8 August 1990 Resolved
REGLASS HOLE IN MN DECK JUST AFT OF HOUSE-STBD SIDE.
Condition: Unknown
Due 8 August 1990
Resolved 8 August 1990
Accommodation/Occupational Safety
Issued 8 August 1990 Resolved
RENEW BRASS SPOOL PIECE FOR THE PORT HEAD INTAKE.
Condition: Unknown
Due 8 August 1990
Resolved 8 August 1990
Construction/Loadline
Issued 8 August 1990 Resolved
REPAIR/RENEW FWD HOLD CAPTIVE CHAIN.
Condition: Unknown
Due 8 August 1990
Resolved 8 August 1990
Electrical
Issued 8 August 1990 Resolved
PROVIDE/INSTALL GLOBE FOR FWD LIGHT IN FWD STOAGE HOLD.
Condition: Unknown
Due 8 August 1990
Resolved 8 August 1990
Lifesaving
Issued 2 May 1990 Resolved
REPAIR W/L BRACKET FOR LIFEFLOAT WATERLIGHT.
Condition: Unknown
Due 2 May 1990
Resolved 2 May 1990
Engineering
Issued 2 May 1990 Resolved
LABEL THE NEW REMOTE SHUTOFF VALVES IAW 46 CFR 185.30-20.
Condition: Unknown
Due 2 May 1990
Resolved 2 May 1990
Lifesaving
Issued 2 May 1990 Resolved
REMOVE DUCT TAPE FROM LIFEFLOAT PENDANTS AND RETIE WITH NOT MORE THAN 2 TURNS OF LIGHT TWINE IAW 46 CFR 160.010-3(I).
Condition: Unknown
Due 2 May 1990
Resolved 2 May 1990
Engineering
Issued 2 May 1990 Resolved
PROVIDE METALLIC SHUTOFF VALVES AT THE FUEL TANK CONNECTION IN THE MAIN ENGINE AND GENERATOR FUEL SUPPLY LINES.
Condition: Unknown
Due 2 May 1990
Resolved 2 May 1990
Engineering
Issued 2 May 1990 Resolved
MAKE THE SHUTOFF VALVES IN #7 OPERABLE FROM OUTSIDE THE FUEL TANK SPACE IAW46 CFR 182.20-40(B)(3).
Condition: Unknown
Due 2 May 1990
Resolved 2 May 1990
Electrical
Issued 2 May 1990 Resolved
PROVIDE A COVER PLATE FOR THE ELECTRICAL OUTLET IN THE PILOTHOUSE.
Condition: Unknown
Due 2 May 1990
Resolved 2 May 1990
Construction/Loadline
Issued 2 May 1990 Resolved
PROVIDE A W/T HATCH FOR THE E/R ACCESS OR PROVIDE A 12" COAMING AROUND THE PRESENT WEATHERTIGHT ACCESS.
Condition: Unknown
Due 2 May 1990
Resolved 2 May 1990
Lifesaving
Issued 2 May 1990 Resolved
RESTENCIL TOPMOST LIFEFLOAT FOR 12 PERSON CAPACITY. VESSEL IS LIMITED TO THE CARRIAGE OF 54 PASSENGERS.
Condition: Unknown
Due 2 May 1990
Resolved 2 May 1990
Lifesaving
Issued 2 May 1990 Resolved
PROVIDE 18' LINES FOR LIFEFLOAT WATERLIGHTS.
Condition: Unknown
Due 2 May 1990
Resolved 2 May 1990
Fire Fighting
Issued 2 May 1990 Resolved
PROVIDE MARINE BRACKETS FOR THE 2 B-II FIRE EXTINGUISHERS IN CABIN.
Condition: Unknown
Due 2 May 1990
Resolved 2 May 1990
Construction/Loadline
Issued 7 February 1989 Resolved
INSTALL 3 VALVE HANDLES ON BILGE WHERE WASTED
Condition: Unknown
Due 7 February 1989
Resolved 7 February 1989
Lifesaving
Issued 7 February 1989 Resolved
INSTALL 12' PENDENTS ON 18" CENTERS OF AT LEAST 1/4" DARK LINE AND INSTALL LIFELINE WITH NO MORE THAN 3' LENGTH BETWEEN STRAPS/18" CENTERS.
Condition: Unknown
Due 7 February 1989
Resolved 7 February 1989
Electrical
Issued 7 February 1989 Resolved
INSTALL GEN CABLES IN A JUNCTION BOX.
Condition: Unknown
Due 7 February 1989
Resolved 7 February 1989
Construction/Loadline
Issued 7 February 1989 Resolved
INSTALL STRAINERS ON SEA VALVES.
Condition: Unknown
Due 7 February 1989
Resolved 7 February 1989
Accommodation/Occupational Safety
Issued 7 February 1989 Resolved
INSTALL A TYPE I, TYPE II, OR TYPE III MSD. TYPES I OR II MUST BE FOR INSPECTED VESSELS AND ALL INSTALLATIONS MUST BE APPROVED BU THIS OFFICE. UNTIL THIS ITEM IS COMPLETED, HEAD DOORS MUST BE LOCKED WHILE TRANSITTING NO DISCHARGE AREAS.
Condition: Unknown
Due 7 February 1989
Resolved 7 February 1989
Documentation
Issued 7 February 1989 Resolved
DRYDOCK DUE 07AUG90. CONTACT USCG BY THIS DATE TO SCHEDULE INSPECTION.
Condition: Unknown
Due 7 February 1989
Resolved 7 February 1989
Engineering
Issued 4 May 1988 Resolved
STENCIL FUEL OIL SHUT OFF VALVES.
Condition: Unknown
Due 4 May 1988
Resolved 4 May 1988
Accommodation/Occupational Safety
Issued 4 May 1988 Resolved
SEAL FUEL FILL IN LADIES HEAD.
Condition: Unknown
Due 4 May 1988
Resolved 4 May 1988
Engineering
Issued 4 May 1988 Resolved
REPLACE FUEL SUPPLY HOSE TO PORT ENGINE WITH ONE THAT HAS AN INNER TUBE AND SYNTHETIC RUBBER COVER AND IS WIRE-BRAID REINFORCED AND WHOSE COVER ISSELF-EXTINGUISHING PER ASTM D1692 OR COAST GUARD CLASS A HOSE OR COPPER TUBING. IN ANY CASE COMPRESSION TYPE FITTINGS MUST BE USED.
Condition: Unknown
Due 4 May 1988
Resolved 4 May 1988
Documentation
Issued 4 May 1988 Resolved
PROVIDE COPY OF INLAND RULES OF THE ROAD ON THE VESSEL.
Condition: Unknown
Due 4 May 1988
Resolved 4 May 1988
Lifesaving
Issued 4 May 1988 Resolved
PROVIDE 30 ADULT TYPE 1 PFD'S WITH LIGHTS AND VSL NAME PRIOR TO CARRYING MORE THAN 46 PASSENGERS.
Condition: Unknown
Due 4 May 1988
Resolved 4 May 1988
Accommodation/Occupational Safety
Issued 4 May 1988 Resolved
PROVIDE WATER TO WASH BASINS IN HEADS THRU INSTALLED PLUMBING PRIOR TO CARRYING MORE THAN 49 PASSENGERS.
Condition: Unknown
Due 4 May 1988
Resolved 4 May 1988
Documentation
Issued 4 May 1988 Resolved
OBTAIN PROOF OF VALID FCC RADIO SAFETY CERTIFICATE.
Condition: Unknown
Due 4 May 1988
Resolved 4 May 1988
Navigation
Issued 4 May 1988 Resolved
OBTAIN 8" SHIPS BELL.
Condition: Unknown
Due 4 May 1988
Resolved 4 May 1988
Engineering
Issued 4 May 1988 Resolved
INSTALL 30X30 FLAME SCREEN ON FUEL VENT PRIOR TO CARRYING PASSENGERS.
Condition: Unknown
Due 4 May 1988
Resolved 4 May 1988
Electrical
Issued 4 May 1988 Resolved
REWIRE AC LIGHTING IN PASS COMPARTMENT WITH MINIMUM 14 AWG STRANDED CONDUCTOR THAT IS UL LISTED. REMOVE ALL 16 AWG CABLE IN PILOT HOUSE AND REPLACE WITH MINIMUM 14AWG STRANDED UL CABLE.
Condition: Unknown
Due 4 May 1988
Resolved 4 May 1988
Deck/Cargo
Issued 20 May 1987 Resolved
LABLE FUEL SHUT OFF VALVE ON FUEL TANKS.
Condition: Unknown
Due 20 May 1987
Resolved 20 May 1987
Electrical
Issued 20 May 1987 Resolved
REPLACE MISSING LIGHT BULB AND GLOBE IN ENGINE ROOM COMPARTMENT
Condition: Unknown
Due 20 May 1987
Resolved 20 May 1987
Electrical
Issued 20 May 1987 Resolved
REMOVE ALL DEAD END WIRES AND REWIRE TO STARBOARD ENGINE AND GENERATOR.
Condition: Unknown
Due 20 May 1987
Resolved 20 May 1987
Construction/Loadline
Issued 20 May 1987 Resolved
REFASTEN UNDERDECK LONGTITUDINAL.
Condition: Unknown
Due 20 May 1987
Resolved 20 May 1987
Electrical
Issued 20 May 1987 Resolved
REPLACE COVER FOR 110 VOLT BOX IN ENGINE COMPARTMENT.
Condition: Unknown
Due 20 May 1987
Resolved 20 May 1987
Lifesaving
Issued 20 May 1987 Resolved
STENCIL VESSEL'S NAME AND CARRYING CAPACITY ON LIFE RAFTS.
Condition: Unknown
Due 20 May 1987
Resolved 20 May 1987
Lifesaving
Issued 20 May 1987 Resolved
REPLACE BATTERY IN WATER LIGHT FOR RING BUOY.
Condition: Unknown
Due 20 May 1987
Resolved 20 May 1987
Lifesaving
Issued 20 May 1987 Resolved
CLEAN LIFE JACKETS.
Condition: Unknown
Due 20 May 1987
Resolved 20 May 1987
Lifesaving
Issued 8 May 1986 Resolved
RENEW OR REWORK 15 MAN LIFEFLOAT. PASSENGERS LIMITED TO 57 OCEANS UNTIL COMPLIED WITH.
Condition: Unknown
Due 8 May 1986
Resolved 8 May 1986
Deck/Cargo
Issued 8 May 1986 Resolved
INSTALL AND MARK FUEL SHUT OFF VALVES ON FUEL TANKS.
Condition: Unknown
Due 8 May 1986
Resolved 8 May 1986

Casualty record · 7

23 June 2009Routine · role: Involved in a Marine Casualty · activity 3514358
6 July 2017Routine · role: Involved in a Marine Casualty · activity 6200877
18 July 2020Routine · role: Involved in a Marine Casualty · activity 7011181
12 June 2021Routine · role: Involved in a Marine Casualty · activity 7261187
15 September 2022Routine · role: Involved in a Marine Casualty · activity 7575335
7 September 2024Routine · role: Involved in a Marine Casualty · activity 8004242
10 January 2026Routine · role: Involved in a Marine Casualty · activity 8294902
Each line is an incident investigation the Coast Guard recorded with this hull among the vessels involved, with the date and the classification the Coast Guard gave it, and the bridge, lock or dam the investigation names where it names one. Involvement is not fault. The investigation narrative is not published. Source: IIR, through 2026.

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.