Records from 2009 to 2026. Most recent: inspection, 30 March 2026.
10 - Safety of Navigation › N/A - No Subsystem › Lights, shapes, sound-signals
Issued 14 May 2026
Resolved
Stbd running light not operating properly and needs replaced. Vessel is restricted to daytime operations and clear visibility. 46 CFR 183.429
Action required: 705 - Other - as specified
Resolved 18 May 2026
Resolution: STBD light replaced and tested
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 14 May 2026
Resolved
03 lifejackets found unserviceable. Vessel restricted to 73 total persons on limited coastwise route during warm weather months. 46 CFR 180.71
Action required: 705 - Other - as specified
Resolved 18 May 2026
Resolution: 03 lifejackets replaced with lights
10 - Safety of Navigation › N/A - No Subsystem › Charts
Issued 14 May 2026
Resolved
Paper navigation charts are wasted and need replaced. 46 CFR 184.420
Action required: 16 - Rectify deficiencies w/in 14 days
Due 28 May 2026
Resolved 15 May 2026
Resolution: New charts on board
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 14 May 2026
Resolved
Fire hose nozzle not the approved type. Replace with nozzle of good grad bronze or equivalent metal.
46 CFR 181.20-1
Action required: 16 - Rectify deficiencies w/in 14 days
Due 28 May 2026
Resolved 15 May 2026
Resolution: Installed approved nozzle
09 - Working and Living Conditions › 091 - Living Conditions › Medical Equipment
Issued 14 May 2026
Resolved
First-Aid kit needs to be in a suitable watertight container and clearly marked, and replace expired aspirin.
46 CFR 184.710
Action required: 16 - Rectify deficiencies w/in 14 days
Due 28 May 2026
Resolved 15 May 2026
Resolution: New watertight container and aspirin
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 14 May 2026
Resolved
Flexible hose coming off of air intake on port main engine is chaffed and worn. Replace with approved flex hose to satisfaction of the MI.
46 CFR 182.410(d)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 28 May 2026
Resolved 15 May 2026
Resolution: Replaced
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 30 March 2026
Resolved
Laz bilge alarm light not working. Repair to satisfaction of MI.
46 CFR 182.530(a)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 28 May 2026
Resolved 15 May 2026
Resolution: Bilge alarm light replaced and tested
18 - Maritime Labour Convention (Not Applicable to PSC Exams conducted in the U.S.) › N/A - No Subsystem › Other (Conditions of employment)
Issued 30 March 2026
Resolved
Employee Assistance Progam not posted.
46 CFR 16
Action required: 16 - Rectify deficiencies w/in 14 days
Due 28 May 2026
Resolved 18 May 2026
Resolution: EAP posted
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 13 May 2025
Resolved
Machinery and equipment installed on each vessel must be suitable for the vessel and its operation and for the purpose intended. All machinery and equipment must be installed and maintained in such a manner as to afford adequate protection from causing fire, explosion, machinery failure, and personnel injury. The starboard engine fuel strainers have broken free from mounts, are hanging loose and subject to the movement of the vessel.
46 CFR 182.100
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 16 May 2025
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 13 May 2025
Resolved
Exhaust gas must not leak from the piping or any connections. There are moderate exhaust fumes in the engine compartment when the engines are running.
46 CFR 182.430
Action required: 16 - Rectify deficiencies w/in 14 days
Due 27 May 2025
Resolved 16 May 2025
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 7 September 2024
Resolved
All machinery and equipment must be installed and maintained in such a manner as to afford adequate protection from causing fire, explosion, machinery failure, and personnel injury; vessel reported a loss of propulsion on STBD side MDE. 46 CFR 182.100
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 11 September 2024
Resolved 11 September 2024
08 - Alarms › N/A - No Subsystem › Other (alarms)
Issued 30 May 2024
Resolved
A visual and audible alarm must be provided at the operating station to indicate high water level in the bilges, the lazarette and engine compartment bilge alarms do not work.
46 CFR 182.530
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 30 May 2024
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 30 May 2024
Resolved
A life jacket must be provided for each person the vessel is authorized to carry; three (3) child size jackets were condemned leaving seven (7) viable child life jackets. The vessel is restricted to a maximum of seven (7) children until additional life jackets are provided.
46 CFR 180.71
Action required: 16 - Rectify deficiencies w/in 14 days
Due 27 June 2024
Resolved 13 May 2025
11 - Life Saving Appliances › N/A - No Subsystem › Other (life saving)
Issued 30 May 2024
Resolved
The name of the vessel must be clearly and legibly marked on the life float paddles; the markings are faded and not legible.
46 CFR 185.604
Action required: 16 - Rectify deficiencies w/in 14 days
Due 13 June 2024
Resolved 12 June 2024
11 - Life Saving Appliances › N/A - No Subsystem › Other (life saving)
Issued 30 May 2024
Resolved
Each life jacket must be marked with Type I reflective material approved in 46 CFR 164.018; a number of life jackets have deteriorated reflective material.
46 CFR 185.604 (h)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 13 June 2024
Resolved 12 June 2024
11 - Life Saving Appliances › N/A - No Subsystem › Other (life saving)
Issued 30 May 2024
Resolved
The name of the vessel must be clearly and legibly marked on each life buoy; the letters on the existing life buoy are peeling off.
46 CFR 185.604
Action required: 16 - Rectify deficiencies w/in 14 days
Due 13 June 2024
Resolved 12 June 2024
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 1 May 2023
Resolved
A vessel must be provided with a satisfactory arrangement for draining any watertight compartment, other than small buoyancy compartments, under all practicable conditions; vessel's fixed bilge pump was unable reliably hold suction
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 2 May 2023
Resolution: Owner replaced flexible discharge hose off pump which was restricted due to collapse.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 1 May 2023
Resolved
Electrical equipment on a vessel must be installed and maintained to Protect passengers, crew, other persons, and the vessel from electrical hazards, including fire, caused by or originating in electrical equipment, and electrical shock; Replace receptacle on fwd bulkhead of ER due to cracking related heat.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 15 May 2023
Resolved 4 May 2023
Resolution: Receptacle removed
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 1 May 2023
Resolved
electrical equipment on a vessel must be installed and maintained to Protect passengers, crew, other persons, and the vessel from electrical hazards, including fire, caused by or originating in electrical equipment, and electrical shock; Remount battery switch in Aft ER. Switch is laying in bilge.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 15 May 2023
Resolved 4 May 2023
Resolution: Switch mounted to aft bulkhead
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 1 May 2023
Resolved
Electrical equipment on a vessel must be installed and maintained to Protect passengers, crew, other persons, and the vessel from electrical hazards, including fire, caused by or originating in electrical equipment, and electrical shock; Remove or replace broke light hanging from STBD exterior of bridge.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 15 May 2023
Resolved 4 May 2023
Resolution: Light removed
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 1 May 2023
Resolved
Electrical equipment on a vessel must be installed and maintained to Protect passengers, crew, other persons, and the vessel from electrical hazards, including fire, caused by or originating in electrical equipment, and electrical shock; properly connect marine romex wire to junction box on light between engines.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 15 May 2023
Resolved 4 May 2023
Resolution: Proper stuffing tube added
09 - Working and Living Conditions › 092 - Working Conditions › Other (accident prevention)
Issued 1 May 2023
Resolved
All escape hatches and other emergency exits used as means of escape must be marked on both sides in clearly legible letters at least 50 millimeters (2 inches) high: “EMERGENCY EXIT, KEEP CLEAR”,ER escape is not labeled.
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Due 15 May 2023
Resolved 4 May 2023
Resolution: Hatch labeled w/ sharpie
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 15 September 2022
Resolved
Propulsion machinery must be suitable in type and design for propulsion requirements of the hull in which it is installed and capable of operating at constant marine load under such requirements without exceeding its designed limitations; vessel experienced unexpected shutdown of Port engine while under way w/ pax.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 16 September 2022
Resolution: Part replaced and engine test sat.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 7 June 2022
Resolved
46CFR180.71- A life jacket approved under 160.002, 005, or 055 must be carried onboard for each person; 11 Adult and 01 Child size life jacket has been condemned; vessel is restricted to 64 adult pax.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 21 June 2022
Resolved 9 June 2022
Resolution: Received photgraphic evidence of new lifejackets
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 13 June 2021
Resolved
Propulsion machinery must be suitable in type and design for propulsion requirements of the hull in which it is installed and capable of operating at constant marine load under such requirements without exceeding its designed limitations; vessel experienced unexpected shutdown of Port engine while under way w/ pax.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 15 June 2021
Resolution: Blower coupling was replaced and vessel was sea trialed sat.
10 - Safety of Navigation › N/A - No Subsystem › Nautical publications
Issued 29 April 2021
Resolved
A vessel must carry adequate and up-to-date navigation publications for the intended route; the Coast Pilot, CG Light List and Notice to Mariners are outdated.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 9 June 2021
10 - Safety of Navigation › N/A - No Subsystem › Lights, shapes, sound-signals
Issued 29 April 2021
Resolved
A vessel must have navigation lights that are in compliance with the International and Inland Navigation Rules; the all around white light is not operational.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 9 June 2021
11 - Life Saving Appliances › N/A - No Subsystem › Buoyant apparatus
Issued 29 April 2021
Resolved
The means of attaching the float free link to the life float must have the breaking strength of at least that of the float free link, if synthetic, be of a dark color and resistant to UV light; the sea painter is deteriorated on one of the life floats.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 9 June 2021
11 - Life Saving Appliances › N/A - No Subsystem › Buoyant apparatus
Issued 29 April 2021
Resolved
Each life float must be equipped with a floating water light certified to meet 160.010; one of the water lights is broken.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 9 June 2021
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 29 April 2021
Resolved
Electrical equipment must be installed and maintained to protect personnel and the vessel from electrical hazards; there are unprotected dead end wires in the engine compartment.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 9 June 2021
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 11 August 2020
Resolved
Where flexible non-metallic hose is permitted, it must meet the required specs for its intended use; STBD side fuel supply hose off Racor filter is in disrepair and in need of replacement.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 25 August 2020
Resolved 18 August 2020
Resolution: Cropped out bad section of hose and installed new fitting.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Manholes/flush scuttles
Issued 11 August 2020
Resolved
A hatch exposed to the weather must be watertight; flush mounted scuttle leading to engineroom has a bad gasket and is not watertight.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 25 August 2020
Resolved 25 August 2020
Resolution: Cleaned out hatch cover and reinstalled gasket with sealant.
07 - Fire Safety › N/A - No Subsystem › Fire pumps and its pipes
Issued 11 August 2020
Resolved
Fire main discharge valve off pump is seized in open position.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 25 August 2020
Resolved 18 August 2020
Resolution: Renewed the valve.
09 - Working and Living Conditions › 092 - Working Conditions › Holds and tanks safety
Issued 11 August 2020
Resolved
The MI shall examine the bilges to see that there is no accumulation of matter which might create fire hazard; fuel tank space has sewage accumulation from valve misalignment.
Condition: Design Flaw
Action required: 701 - Prior to carriage of passengers/cargo
Due 11 August 2020
Resolved 11 August 2020
Resolution: Operator pumped space to shore and cleaned.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 11 August 2020
Resolved
The vessel must be provided w/ a satisfactory arrangement for draining any watertight compartment; bilge suction valve is corroded and not usable.
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Due 11 August 2020
Resolved 11 August 2020
Resolution: Crew applied liquid penetrant and freed valve prior to completing the inspection
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 19 July 2020
Resolved
Propulsion machinery must be suitable in type and design for propulsion requirements of the hull in which it is installed and capable of operating at constant marine load under such requirements without exceeding its designed limitations. Vsl experienced loss of propulsion in the port main engine. Repair and conduct sea trials to prove proper operation to satisfaction of attending marine inspector prior to carrying passengers.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 20 July 2020
Resolution: Attended vessel moored Carolina Beach. Witnessed satisfactory test of both main engines.
09 - Working and Living Conditions › 092 - Working Conditions › Machinery
Issued 30 July 2019
Resolved
Numerous hose connections within the engine compartment do not have two hose clamps as required; install a second hose clamp as follows, (2) through hull connections stbd side fwd, (1) through hull for wash down pump, (1) on the port main engine exhaust system.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 13 August 2019
07 - Fire Safety › N/A - No Subsystem › Remote Means of control (opening,pumps,ventilation,etc.) Machinery spaces
Issued 30 July 2019
Resolved
The remote shutoff valves for the fuel system are not labeled, properly mark the valves "Fuel Shutoff".
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 13 August 2019
09 - Working and Living Conditions › 092 - Working Conditions › Machinery
Issued 30 July 2019
Resolved
The valve handle for the wash down pump raw water intake is broken; permanently affix a combination wrench to the valve until next haul out.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 13 August 2019
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 30 July 2019
Resolved
Repair or replace the broken light in the passenger accommodation space.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 13 August 2019
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Auxiliary engine
Issued 30 July 2019
Resolved
The generator is not operational due to defective solenoid; repair the generator as needed.
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 13 August 2019
04 - Emergency Systems › N/A - No Subsystem › Public address system
Issued 1 August 2018
Resolved
The vessel has a megaphone in lieu of a PA system, however it does not work; provide the vessel with a suitable PA system or megaphone.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 1 August 2018
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 1 August 2018
Resolved
The stbd main engine raw water intake hose is missing two hose clamps; install hose clamps where needed.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 1 August 2018
Navigation › Collision/Grounding Avoidance › Navigation Lights
Issued 21 April 2017
Resolved
Repair the stern light due to failure.
Due 20 May 2017
Resolved 5 May 2017
Engineering › Lubricating Oil Service System › Gauge
Issued 21 April 2017
Resolved
Repair or replace the lube oil pressure gauge for the port main engine.
Due 20 May 2017
Resolved 5 May 2017
Engineering › Diesel Engine (auxiliary) › Piping (exhaust)
Issued 21 April 2017
Resolved
Install an additional hose clamp on the exhaust hose to the generator IWO the bhd penetration.
Due 20 May 2017
Resolved 5 May 2017
Electrical › Electric Supply System (service) › Battery Conductor
Issued 21 April 2017
Resolved
Remove excessive wire connections from the generator battery and install a terminal bus bar.
Due 20 May 2017
Resolved 5 May 2017
Engineering › Bilge Water Management System › Strainer
Issued 21 April 2017
Resolved
Clean the bilge suction strainer in the fuel tank compartment due to blockage.
Due 20 May 2017
Resolved 5 May 2017
Engineering › Diesel Engine (auxiliary) › Piping (exhaust)
Issued 21 April 2017
Resolved
The generator exhaust hose is chaffing on the side stringers in the steering compartment; install chaffing gear as needed.
Due 20 May 2017
Resolved 1 September 2017
Engineering › Steering Gear System › Piping
Issued 21 April 2017
Resolved
Repair the hydraulic fluid leak in the steering compartment.
Due 20 May 2017
Resolved 5 May 2017
Electrical › Electric Supply System (service) › Overcurrent Device
Issued 21 April 2017
Resolved
Provide overcurrent protection for the conductors on the stbd battery in the engine compartment.
Due 20 May 2017
Resolved 5 May 2017
Electrical › Electric Supply System (service) › Cable
Issued 21 April 2017
Resolved
Replace the deteriorated conductor on the stbd bus bar in the engine compartment.
Due 20 May 2017
Resolved 5 May 2017
Electrical › Electric Supply System (service) › Cable
Issued 21 April 2017
Resolved
Replace the deteriorated conductor on the generator battery.
Due 20 May 2017
Resolved 5 May 2017
Electrical › Electrical Distribution System (service) › Wiring
Issued 21 April 2017
Resolved
Remove wire nuts and install butt connectors in wiring on the port side of the engine compartment.
Due 20 May 2017
Resolved 5 May 2017
Electrical › Electrical Distribution System (service) › Wiring
Issued 21 April 2017
Resolved
Properly terminate the dead end wires in the engine compartment, port side forward.
Due 20 May 2017
Resolved 5 May 2017
Electrical › Electric Supply System (service) › Cable
Issued 21 April 2017
Resolved
Replace the deteriorated conductor on the port battery in the engine compartment.
Due 20 May 2017
Resolved 5 May 2017
Stability › Watertight Integrity › General
Issued 21 April 2017
Resolved
Reinstall the captive chain for the aft hatch cover.
Due 20 May 2017
Resolved 5 May 2017
Stability › Watertight Integrity › General
Issued 21 April 2017
Resolved
Properly seal the through hull fitting on the stbd side in the forward void.
Due 20 May 2017
Resolved 5 May 2017
Lifesaving › Lifefloat › Serviceable
Issued 18 May 2016
Resolved
Repaint and seal holes on lifefloats as needed.
Due 2 June 2016
Resolved 3 June 2016
Lifesaving › Lifefloat › Painter
Issued 18 May 2016
Resolved
Ensure all lifefloat sea painters are 100 ft.
Due 2 June 2016
Resolved 3 June 2016
Electrical › Electric Supply System (service) › Cable
Issued 18 May 2016
Resolved
On newly replaced electrical box in engine room-install backing nuts for wire knockouts.
Due 18 June 2016
Resolved 3 June 2016
Electrical › Electrical Distribution System (service) › Wiring
Issued 18 May 2016
Resolved
Replace wire nuts in lazarette - fresh water pump and #1 void - bilge pump, with crimp connectors or locate inside a junction box with electrical tape overwrap.
Due 18 June 2016
Resolved 3 June 2016
Communications › Radio Communications › VHF Radiotelephone
Issued 18 May 2016
Resolved
Connect GPS to VHF radio and input MMSI number, show proper operation.
Due 18 June 2016
Resolved 21 April 2017
Electrical › Electric Supply System (service) › Battery Installation
Issued 18 May 2016
Resolved
Replace 01 battery on STBD battery bank, rewire conductors ensuring no greater than 4 connected to any 1 terminal.
Due 18 June 2016
Resolved 3 June 2016
Stability › Watertight Integrity › Watertight Subdivision Standard
Issued 18 May 2016
Resolved
Make appropriate repairs to engine room hatch. Prove watertight seal.
Due 18 June 2016
Resolved 3 June 2016