MAURY USCG vessel records
← All vessels

VONDA KAY

VONDA KAY is a 1976 passenger vessel (inspected). The Coast Guard has recorded 28 inspections since 2016, most recently in March 2026, along with 65 deficiencies and 7 casualty investigations between 2009 and 2026.

Records from 2009 to 2026. Most recent: inspection, 30 March 2026.

Built
1976
Last inspected
30 March 2026
Documentation
Valid · documentation file of 10 August 2026
Controls
None recorded without a removal date

Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 2016.

Inspection record

Last inspected 30 March 2026
…with no type recorded6
Operational controls None recorded without a removal date
Years with a record 11 calendar years (2016–2026)
Every line above is a count of records the US Coast Guard wrote, or a date it recorded. A blank resolution means none was recorded in this data; it does not establish that a deficiency is outstanding. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Identity

WCZ3557
Flag
UNITED STATES
Maury page id
psix-54954

Documentation record

Registered dimensions (L × B × D)58.8 ft × 18.9 ft × 7.0 ft
Registered tonnagegross 67 / net 47
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderSTAPLETON BOAT CORP · MIAMI FL, UNITED STATES · built 1976
Hull materialFRP (Fiberglass)
PropulsionDiesel Reduction
Hull shapeUNSPECIFIED
Hull configurationUNSPECIFIED
Hailing portTOPSAIL BEACH, NC
Trade endorsementsCoastwise, unrestricted, Fishery, Recreational
DocumentationValid · issued 25 February 2026 · expires 28 February 2027
Service, as the file records itPassenger (Inspected)
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it67 - Regulatory (Subpart C or D), Gross Ton
47 - Regulatory (Subpart C or D), Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 August 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
Vessel history report
Every record for this hull, in one document — $299

Every recorded inspection, 2016 to 2026 for this class, in one chronology · every deficiency, with system, dates and resolution · operational controls imposed and removed · every name this hull has been recorded under · the vessels it was inspected alongside, and when · how its record compares with hulls of similar age and size, as a fact about the population and never a judgement about this vessel.

Read one first, in full: a forty-year chronology · a hull that changed operators four times · the sparse case, shown as an example, not for sale.

This report is in development and is not for sale yet. There is no date, and nothing is charged. Leave an email and we will tell you when it exists, once.

Inspection history · 28

30 March 2026 Internal Structural Exam · COI Inspection · Deficiency Check · Hull Examination · Vessel Attendance
Physical examination · Sector North Carolina · USCG East District (CGD-E) · Activity 8334108
10 January 2026 Deficiency Check · In-Service Inspection
Physical examination · Sector North Carolina · USCG East District (CGD-E) · Activity 8294216
10 January 2026 Type not recorded
No type recorded · Sector North Carolina · USCG East District (CGD-E) · Activity 8294902
13 May 2025 Deficiency Check · Annual Inspection
Physical examination · Sector North Carolina · USCG East District (CGD-E) · Activity 8134877
7 September 2024 Deficiency Check · In-Service Inspection
Physical examination · Sector North Carolina · USCG East District (CGD-E) · Activity 7998344
7 September 2024 Type not recorded
No type recorded · Sector North Carolina · USCG East District (CGD-E) · Activity 8004242
30 May 2024 Deficiency Check · Annual Inspection
Physical examination · Sector North Carolina · USCG East District (CGD-E) · Activity 7922956
19 April 2024 Drydock Exam · Internal Structural Exam · Hull Examination · Deficiency Check
Physical examination · Sector North Carolina · USCG East District (CGD-E) · Activity 7898033
1 August 2023 In-Service Inspection
Physical examination · Sector North Carolina · USCG East District (CGD-E) · Activity 7786342
1 May 2023 Annual Inspection · Deficiency Check
Physical examination · Sector North Carolina · USCG East District (CGD-E) · Activity 7678549
15 September 2022 Examination of Repairs · Damage Survey
Physical examination · Sector North Carolina · USCG East District (CGD-E) · Activity 7559863
15 September 2022 Type not recorded
No type recorded · Sector North Carolina · USCG East District (CGD-E) · Activity 7575335
7 June 2022 Deficiency Check · Annual Inspection
Physical examination · Sector North Carolina · USCG East District (CGD-E) · Activity 7470770
5 April 2022 Examination of Repairs · Hull Examination · Internal Structural Exam
Physical examination · Sector North Carolina · USCG East District (CGD-E) · Activity 7424762
13 June 2021 Deficiency Check · Administrative Inspection · Damage Survey
Physical examination · Sector North Carolina · USCG East District (CGD-E) · Activity 7223770
12 June 2021 Type not recorded
No type recorded · Sector North Carolina · USCG East District (CGD-E) · Activity 7261187
29 April 2021 Deficiency Check · COI Inspection · Administrative Inspection
Physical examination · Sector North Carolina · USCG East District (CGD-E) · Activity 7185310
11 August 2020 Annual Inspection · Deficiency Check
Physical examination · Sector North Carolina · USCG East District (CGD-E) · Activity 7029784
18 July 2020 Damage Survey · Deficiency Check
Physical examination · Sector North Carolina · USCG East District (CGD-E) · Activity 7009726
18 July 2020 Type not recorded
No type recorded · Sector North Carolina · USCG East District (CGD-E) · Activity 7011181
10 March 2020 Internal Structural Exam · Hull Examination · Administrative Inspection · Examination of Repairs · Drydock Exam
Physical examination · Sector North Carolina · USCG East District (CGD-E) · Activity 6923692
30 July 2019 Deficiency Check · Annual Inspection · Administrative Inspection
Physical examination · Sector North Carolina · USCG East District (CGD-E) · Activity 6766656
1 August 2018 Annual Inspection · Deficiency Check · Administrative Inspection
Physical examination · Sector North Carolina · USCG East District (CGD-E) · Activity 6497534
30 March 2018 Examination of Repairs · Drydock Exam · Hull Examination · Administrative Inspection
Physical examination · Sector North Carolina · USCG East District (CGD-E) · Activity 6381704
1 September 2017 Deficiency Check
Physical examination · Sector North Carolina · USCG East District (CGD-E) · Activity 6265686
6 July 2017 Type not recorded
No type recorded · Sector North Carolina · USCG East District (CGD-E) · Activity 6200877
21 April 2017 Annual Inspection · Administrative Inspection · Deficiency Check
Physical examination · Sector North Carolina · USCG East District (CGD-E) · Activity 6129496
11 April 2016 Deficiency Check · Drydock Exam · Internal Structural Exam · Hull Examination · COI Inspection
Physical examination · Sector North Carolina · USCG East District (CGD-E) · Activity 5851211

Deficiency record · 65

10 - Safety of Navigation › N/A - No Subsystem › Lights, shapes, sound-signals
Issued 14 May 2026 Resolved
Stbd running light not operating properly and needs replaced. Vessel is restricted to daytime operations and clear visibility. 46 CFR 183.429
Action required: 705 - Other - as specified
Resolved 18 May 2026
Resolution: STBD light replaced and tested
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 14 May 2026 Resolved
03 lifejackets found unserviceable. Vessel restricted to 73 total persons on limited coastwise route during warm weather months. 46 CFR 180.71
Action required: 705 - Other - as specified
Resolved 18 May 2026
Resolution: 03 lifejackets replaced with lights
10 - Safety of Navigation › N/A - No Subsystem › Charts
Issued 14 May 2026 Resolved
Paper navigation charts are wasted and need replaced. 46 CFR 184.420
Action required: 16 - Rectify deficiencies w/in 14 days
Due 28 May 2026
Resolved 15 May 2026
Resolution: New charts on board
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 14 May 2026 Resolved
Fire hose nozzle not the approved type. Replace with nozzle of good grad bronze or equivalent metal. 46 CFR 181.20-1
Action required: 16 - Rectify deficiencies w/in 14 days
Due 28 May 2026
Resolved 15 May 2026
Resolution: Installed approved nozzle
09 - Working and Living Conditions › 091 - Living Conditions › Medical Equipment
Issued 14 May 2026 Resolved
First-Aid kit needs to be in a suitable watertight container and clearly marked, and replace expired aspirin. 46 CFR 184.710
Action required: 16 - Rectify deficiencies w/in 14 days
Due 28 May 2026
Resolved 15 May 2026
Resolution: New watertight container and aspirin
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 14 May 2026 Resolved
Flexible hose coming off of air intake on port main engine is chaffed and worn. Replace with approved flex hose to satisfaction of the MI. 46 CFR 182.410(d)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 28 May 2026
Resolved 15 May 2026
Resolution: Replaced
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 30 March 2026 Resolved
Laz bilge alarm light not working. Repair to satisfaction of MI. 46 CFR 182.530(a)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 28 May 2026
Resolved 15 May 2026
Resolution: Bilge alarm light replaced and tested
18 - Maritime Labour Convention (Not Applicable to PSC Exams conducted in the U.S.) › N/A - No Subsystem › Other (Conditions of employment)
Issued 30 March 2026 Resolved
Employee Assistance Progam not posted. 46 CFR 16
Action required: 16 - Rectify deficiencies w/in 14 days
Due 28 May 2026
Resolved 18 May 2026
Resolution: EAP posted
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 13 May 2025 Resolved
Machinery and equipment installed on each vessel must be suitable for the vessel and its operation and for the purpose intended. All machinery and equipment must be installed and maintained in such a manner as to afford adequate protection from causing fire, explosion, machinery failure, and personnel injury. The starboard engine fuel strainers have broken free from mounts, are hanging loose and subject to the movement of the vessel. 46 CFR 182.100
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 16 May 2025
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 13 May 2025 Resolved
Exhaust gas must not leak from the piping or any connections. There are moderate exhaust fumes in the engine compartment when the engines are running. 46 CFR 182.430
Action required: 16 - Rectify deficiencies w/in 14 days
Due 27 May 2025
Resolved 16 May 2025
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 7 September 2024 Resolved
All machinery and equipment must be installed and maintained in such a manner as to afford adequate protection from causing fire, explosion, machinery failure, and personnel injury; vessel reported a loss of propulsion on STBD side MDE. 46 CFR 182.100
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 11 September 2024
Resolved 11 September 2024
08 - Alarms › N/A - No Subsystem › Other (alarms)
Issued 30 May 2024 Resolved
A visual and audible alarm must be provided at the operating station to indicate high water level in the bilges, the lazarette and engine compartment bilge alarms do not work. 46 CFR 182.530
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 30 May 2024
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 30 May 2024 Resolved
A life jacket must be provided for each person the vessel is authorized to carry; three (3) child size jackets were condemned leaving seven (7) viable child life jackets. The vessel is restricted to a maximum of seven (7) children until additional life jackets are provided. 46 CFR 180.71
Action required: 16 - Rectify deficiencies w/in 14 days
Due 27 June 2024
Resolved 13 May 2025
11 - Life Saving Appliances › N/A - No Subsystem › Other (life saving)
Issued 30 May 2024 Resolved
The name of the vessel must be clearly and legibly marked on the life float paddles; the markings are faded and not legible. 46 CFR 185.604
Action required: 16 - Rectify deficiencies w/in 14 days
Due 13 June 2024
Resolved 12 June 2024
11 - Life Saving Appliances › N/A - No Subsystem › Other (life saving)
Issued 30 May 2024 Resolved
Each life jacket must be marked with Type I reflective material approved in 46 CFR 164.018; a number of life jackets have deteriorated reflective material. 46 CFR 185.604 (h)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 13 June 2024
Resolved 12 June 2024
11 - Life Saving Appliances › N/A - No Subsystem › Other (life saving)
Issued 30 May 2024 Resolved
The name of the vessel must be clearly and legibly marked on each life buoy; the letters on the existing life buoy are peeling off. 46 CFR 185.604
Action required: 16 - Rectify deficiencies w/in 14 days
Due 13 June 2024
Resolved 12 June 2024
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 1 May 2023 Resolved
A vessel must be provided with a satisfactory arrangement for draining any watertight compartment, other than small buoyancy compartments, under all practicable conditions; vessel's fixed bilge pump was unable reliably hold suction
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 2 May 2023
Resolution: Owner replaced flexible discharge hose off pump which was restricted due to collapse.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 1 May 2023 Resolved
Electrical equipment on a vessel must be installed and maintained to Protect passengers, crew, other persons, and the vessel from electrical hazards, including fire, caused by or originating in electrical equipment, and electrical shock; Replace receptacle on fwd bulkhead of ER due to cracking related heat.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 15 May 2023
Resolved 4 May 2023
Resolution: Receptacle removed
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 1 May 2023 Resolved
electrical equipment on a vessel must be installed and maintained to Protect passengers, crew, other persons, and the vessel from electrical hazards, including fire, caused by or originating in electrical equipment, and electrical shock; Remount battery switch in Aft ER. Switch is laying in bilge.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 15 May 2023
Resolved 4 May 2023
Resolution: Switch mounted to aft bulkhead
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 1 May 2023 Resolved
Electrical equipment on a vessel must be installed and maintained to Protect passengers, crew, other persons, and the vessel from electrical hazards, including fire, caused by or originating in electrical equipment, and electrical shock; Remove or replace broke light hanging from STBD exterior of bridge.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 15 May 2023
Resolved 4 May 2023
Resolution: Light removed
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 1 May 2023 Resolved
Electrical equipment on a vessel must be installed and maintained to Protect passengers, crew, other persons, and the vessel from electrical hazards, including fire, caused by or originating in electrical equipment, and electrical shock; properly connect marine romex wire to junction box on light between engines.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 15 May 2023
Resolved 4 May 2023
Resolution: Proper stuffing tube added
09 - Working and Living Conditions › 092 - Working Conditions › Other (accident prevention)
Issued 1 May 2023 Resolved
All escape hatches and other emergency exits used as means of escape must be marked on both sides in clearly legible letters at least 50 millimeters (2 inches) high: “EMERGENCY EXIT, KEEP CLEAR”,ER escape is not labeled.
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Due 15 May 2023
Resolved 4 May 2023
Resolution: Hatch labeled w/ sharpie
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 15 September 2022 Resolved
Propulsion machinery must be suitable in type and design for propulsion requirements of the hull in which it is installed and capable of operating at constant marine load under such requirements without exceeding its designed limitations; vessel experienced unexpected shutdown of Port engine while under way w/ pax.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 16 September 2022
Resolution: Part replaced and engine test sat.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 7 June 2022 Resolved
46CFR180.71- A life jacket approved under 160.002, 005, or 055 must be carried onboard for each person; 11 Adult and 01 Child size life jacket has been condemned; vessel is restricted to 64 adult pax.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 21 June 2022
Resolved 9 June 2022
Resolution: Received photgraphic evidence of new lifejackets
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 13 June 2021 Resolved
Propulsion machinery must be suitable in type and design for propulsion requirements of the hull in which it is installed and capable of operating at constant marine load under such requirements without exceeding its designed limitations; vessel experienced unexpected shutdown of Port engine while under way w/ pax.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 15 June 2021
Resolution: Blower coupling was replaced and vessel was sea trialed sat.
10 - Safety of Navigation › N/A - No Subsystem › Nautical publications
Issued 29 April 2021 Resolved
A vessel must carry adequate and up-to-date navigation publications for the intended route; the Coast Pilot, CG Light List and Notice to Mariners are outdated.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 9 June 2021
10 - Safety of Navigation › N/A - No Subsystem › Lights, shapes, sound-signals
Issued 29 April 2021 Resolved
A vessel must have navigation lights that are in compliance with the International and Inland Navigation Rules; the all around white light is not operational.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 9 June 2021
11 - Life Saving Appliances › N/A - No Subsystem › Buoyant apparatus
Issued 29 April 2021 Resolved
The means of attaching the float free link to the life float must have the breaking strength of at least that of the float free link, if synthetic, be of a dark color and resistant to UV light; the sea painter is deteriorated on one of the life floats.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 9 June 2021
11 - Life Saving Appliances › N/A - No Subsystem › Buoyant apparatus
Issued 29 April 2021 Resolved
Each life float must be equipped with a floating water light certified to meet 160.010; one of the water lights is broken.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 9 June 2021
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 29 April 2021 Resolved
Electrical equipment must be installed and maintained to protect personnel and the vessel from electrical hazards; there are unprotected dead end wires in the engine compartment.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 9 June 2021
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 11 August 2020 Resolved
Where flexible non-metallic hose is permitted, it must meet the required specs for its intended use; STBD side fuel supply hose off Racor filter is in disrepair and in need of replacement.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 25 August 2020
Resolved 18 August 2020
Resolution: Cropped out bad section of hose and installed new fitting.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Manholes/flush scuttles
Issued 11 August 2020 Resolved
A hatch exposed to the weather must be watertight; flush mounted scuttle leading to engineroom has a bad gasket and is not watertight.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 25 August 2020
Resolved 25 August 2020
Resolution: Cleaned out hatch cover and reinstalled gasket with sealant.
07 - Fire Safety › N/A - No Subsystem › Fire pumps and its pipes
Issued 11 August 2020 Resolved
Fire main discharge valve off pump is seized in open position.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 25 August 2020
Resolved 18 August 2020
Resolution: Renewed the valve.
09 - Working and Living Conditions › 092 - Working Conditions › Holds and tanks safety
Issued 11 August 2020 Resolved
The MI shall examine the bilges to see that there is no accumulation of matter which might create fire hazard; fuel tank space has sewage accumulation from valve misalignment.
Condition: Design Flaw
Action required: 701 - Prior to carriage of passengers/cargo
Due 11 August 2020
Resolved 11 August 2020
Resolution: Operator pumped space to shore and cleaned.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 11 August 2020 Resolved
The vessel must be provided w/ a satisfactory arrangement for draining any watertight compartment; bilge suction valve is corroded and not usable.
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Due 11 August 2020
Resolved 11 August 2020
Resolution: Crew applied liquid penetrant and freed valve prior to completing the inspection
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 19 July 2020 Resolved
Propulsion machinery must be suitable in type and design for propulsion requirements of the hull in which it is installed and capable of operating at constant marine load under such requirements without exceeding its designed limitations. Vsl experienced loss of propulsion in the port main engine. Repair and conduct sea trials to prove proper operation to satisfaction of attending marine inspector prior to carrying passengers.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 20 July 2020
Resolution: Attended vessel moored Carolina Beach. Witnessed satisfactory test of both main engines.
09 - Working and Living Conditions › 092 - Working Conditions › Machinery
Issued 30 July 2019 Resolved
Numerous hose connections within the engine compartment do not have two hose clamps as required; install a second hose clamp as follows, (2) through hull connections stbd side fwd, (1) through hull for wash down pump, (1) on the port main engine exhaust system.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 13 August 2019
07 - Fire Safety › N/A - No Subsystem › Remote Means of control (opening,pumps,ventilation,etc.) Machinery spaces
Issued 30 July 2019 Resolved
The remote shutoff valves for the fuel system are not labeled, properly mark the valves "Fuel Shutoff".
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 13 August 2019
09 - Working and Living Conditions › 092 - Working Conditions › Machinery
Issued 30 July 2019 Resolved
The valve handle for the wash down pump raw water intake is broken; permanently affix a combination wrench to the valve until next haul out.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 13 August 2019
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 30 July 2019 Resolved
Repair or replace the broken light in the passenger accommodation space.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 13 August 2019
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Auxiliary engine
Issued 30 July 2019 Resolved
The generator is not operational due to defective solenoid; repair the generator as needed.
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 13 August 2019
04 - Emergency Systems › N/A - No Subsystem › Public address system
Issued 1 August 2018 Resolved
The vessel has a megaphone in lieu of a PA system, however it does not work; provide the vessel with a suitable PA system or megaphone.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 1 August 2018
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 1 August 2018 Resolved
The stbd main engine raw water intake hose is missing two hose clamps; install hose clamps where needed.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 1 August 2018
Navigation › Collision/Grounding Avoidance › Navigation Lights
Issued 21 April 2017 Resolved
Repair the stern light due to failure.
Due 20 May 2017
Resolved 5 May 2017
Engineering › Lubricating Oil Service System › Gauge
Issued 21 April 2017 Resolved
Repair or replace the lube oil pressure gauge for the port main engine.
Due 20 May 2017
Resolved 5 May 2017
Engineering › Diesel Engine (auxiliary) › Piping (exhaust)
Issued 21 April 2017 Resolved
Install an additional hose clamp on the exhaust hose to the generator IWO the bhd penetration.
Due 20 May 2017
Resolved 5 May 2017
Electrical › Electric Supply System (service) › Battery Conductor
Issued 21 April 2017 Resolved
Remove excessive wire connections from the generator battery and install a terminal bus bar.
Due 20 May 2017
Resolved 5 May 2017
Engineering › Bilge Water Management System › Strainer
Issued 21 April 2017 Resolved
Clean the bilge suction strainer in the fuel tank compartment due to blockage.
Due 20 May 2017
Resolved 5 May 2017
Engineering › Diesel Engine (auxiliary) › Piping (exhaust)
Issued 21 April 2017 Resolved
The generator exhaust hose is chaffing on the side stringers in the steering compartment; install chaffing gear as needed.
Due 20 May 2017
Resolved 1 September 2017
Engineering › Steering Gear System › Piping
Issued 21 April 2017 Resolved
Repair the hydraulic fluid leak in the steering compartment.
Due 20 May 2017
Resolved 5 May 2017
Electrical › Electric Supply System (service) › Overcurrent Device
Issued 21 April 2017 Resolved
Provide overcurrent protection for the conductors on the stbd battery in the engine compartment.
Due 20 May 2017
Resolved 5 May 2017
Electrical › Electric Supply System (service) › Cable
Issued 21 April 2017 Resolved
Replace the deteriorated conductor on the stbd bus bar in the engine compartment.
Due 20 May 2017
Resolved 5 May 2017
Electrical › Electric Supply System (service) › Cable
Issued 21 April 2017 Resolved
Replace the deteriorated conductor on the generator battery.
Due 20 May 2017
Resolved 5 May 2017
Electrical › Electrical Distribution System (service) › Wiring
Issued 21 April 2017 Resolved
Remove wire nuts and install butt connectors in wiring on the port side of the engine compartment.
Due 20 May 2017
Resolved 5 May 2017
Electrical › Electrical Distribution System (service) › Wiring
Issued 21 April 2017 Resolved
Properly terminate the dead end wires in the engine compartment, port side forward.
Due 20 May 2017
Resolved 5 May 2017
Electrical › Electric Supply System (service) › Cable
Issued 21 April 2017 Resolved
Replace the deteriorated conductor on the port battery in the engine compartment.
Due 20 May 2017
Resolved 5 May 2017
Stability › Watertight Integrity › General
Issued 21 April 2017 Resolved
Reinstall the captive chain for the aft hatch cover.
Due 20 May 2017
Resolved 5 May 2017
Stability › Watertight Integrity › General
Issued 21 April 2017 Resolved
Properly seal the through hull fitting on the stbd side in the forward void.
Due 20 May 2017
Resolved 5 May 2017
Lifesaving › Lifefloat › Serviceable
Issued 18 May 2016 Resolved
Repaint and seal holes on lifefloats as needed.
Due 2 June 2016
Resolved 3 June 2016
Lifesaving › Lifefloat › Painter
Issued 18 May 2016 Resolved
Ensure all lifefloat sea painters are 100 ft.
Due 2 June 2016
Resolved 3 June 2016
Electrical › Electric Supply System (service) › Cable
Issued 18 May 2016 Resolved
On newly replaced electrical box in engine room-install backing nuts for wire knockouts.
Due 18 June 2016
Resolved 3 June 2016
Electrical › Electrical Distribution System (service) › Wiring
Issued 18 May 2016 Resolved
Replace wire nuts in lazarette - fresh water pump and #1 void - bilge pump, with crimp connectors or locate inside a junction box with electrical tape overwrap.
Due 18 June 2016
Resolved 3 June 2016
Communications › Radio Communications › VHF Radiotelephone
Issued 18 May 2016 Resolved
Connect GPS to VHF radio and input MMSI number, show proper operation.
Due 18 June 2016
Resolved 21 April 2017
Electrical › Electric Supply System (service) › Battery Installation
Issued 18 May 2016 Resolved
Replace 01 battery on STBD battery bank, rewire conductors ensuring no greater than 4 connected to any 1 terminal.
Due 18 June 2016
Resolved 3 June 2016
Stability › Watertight Integrity › Watertight Subdivision Standard
Issued 18 May 2016 Resolved
Make appropriate repairs to engine room hatch. Prove watertight seal.
Due 18 June 2016
Resolved 3 June 2016

Casualty record · 7

23 June 2009Routine · role: Involved in a Marine Casualty · activity 3514358
6 July 2017Routine · role: Involved in a Marine Casualty · activity 6200877
18 July 2020Routine · role: Involved in a Marine Casualty · activity 7011181
12 June 2021Routine · role: Involved in a Marine Casualty · activity 7261187
15 September 2022Routine · role: Involved in a Marine Casualty · activity 7575335
7 September 2024Routine · role: Involved in a Marine Casualty · activity 8004242
10 January 2026Routine · role: Involved in a Marine Casualty · activity 8294902
Each line is an incident investigation the Coast Guard recorded with this hull among the vessels involved, with the date and the classification the Coast Guard gave it. Involvement is not fault. The investigation narrative is not published. Source: IIR, through 2026.

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.