MAURY USCG vessel records Sign in
← All vessels

GLOMAR ADRIATIC VIII

GLOMAR ADRIATIC VIII is a 1983 mobile offshore drilling unit. The Coast Guard has recorded 42 inspections since 1985, most recently in March 2005, along with 72 deficiencies.

Records from 1985 to 2005. Most recent: inspection, 14 March 2005.

Built
1983
Last inspected
14 March 2005
Documentation
Not in the documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

Flag
UNITED STATES
—
Maury page id
psix-54960

Inspections, by type

…with no type recorded18
Years with a record 13 calendar years (1985–2005)
The 42 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

This record may be incomplete: the most recent inspection recorded for this vessel was 21 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Offshore class in Maury's sources begin in 1978.

Documentation record

Tonnage as PSIX records it4581 - Regulatory (Subpart C or D), Gross Ton
7895 - Convention (Subpart B), Gross Ton
4581 - Regulatory (Subpart C or D), Net Ton
2368 - Convention (Subpart B), Net Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.

Radio station licence

No FCC ship-station licence is recorded against this Official Number in the file of 6 September 2026. That is a fact about the licence file, not about the radio.

A report is not offered for this hull: Its record holds only 2 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. Reports.

Inspection history · 42

14 March 2005 Deficiency Check
Physical examination · Activities Europe · Activity 2309657
26 January 1998 Administrative
Administrative · Activities Europe · Activity 1115510
25 November 1997 Type not recorded
No type recorded · Activities Europe · Activity 782829
7 November 1997 Administrative
Administrative · Activities Europe · Activity 784431
4 November 1997 Type not recorded
No type recorded · Activities Europe · Activity 780953
15 August 1997 Administrative
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1118975
14 March 1996 Type not recorded
No type recorded · Activities Europe · Activity 89350
16 October 1994 Type not recorded
No type recorded · Marine Safety Detachment Kenai · USCG Arctic District (CGD-A) · Activity 656032
12 October 1994 Administrative
Administrative · MSO ANCHORAGE · USCG Arctic District (CGD-A) · Activity 863138
12 October 1994 Hull Examination · MARPOL Annex V Examination · COI Inspection
Physical examination · MSO ANCHORAGE · USCG Arctic District (CGD-A) · Activity 1367184
5 October 1994 Type not recorded
No type recorded · Marine Safety Detachment Kenai · USCG Arctic District (CGD-A) · Activity 656027
29 September 1994 Type not recorded
No type recorded · Marine Safety Detachment Kenai · USCG Arctic District (CGD-A) · Activity 162288
4 May 1994 Administrative
Administrative · MSO ANCHORAGE · USCG Arctic District (CGD-A) · Activity 858564
4 May 1994 Administrative
Administrative · MSO ANCHORAGE · USCG Arctic District (CGD-A) · Activity 1168812
19 October 1993 Re-Inspection · MARPOL Annex V Examination
Physical examination · MSO ANCHORAGE · USCG Arctic District (CGD-A) · Activity 1389710
16 June 1993 Deficiency Check · Plan Review "T" Boat
Physical examination · MSO ANCHORAGE · USCG Arctic District (CGD-A) · Activity 847351
6 May 1993 Type not recorded
No type recorded · MSO ANCHORAGE · USCG Arctic District (CGD-A) · Activity 1149904
16 April 1993 Deficiency Check
Physical examination · MSO ANCHORAGE · USCG Arctic District (CGD-A) · Activity 1132367
11 December 1992 Hull Examination · COI Inspection
Physical examination · MSO ANCHORAGE · USCG Arctic District (CGD-A) · Activity 837141
25 November 1992 Type not recorded
No type recorded · Marine Safety Detachment Kenai · USCG Arctic District (CGD-A) · Activity 162352
10 November 1992 Type not recorded
No type recorded · Marine Safety Detachment Kenai · USCG Arctic District (CGD-A) · Activity 656029
2 November 1992 Type not recorded
No type recorded · Marine Safety Detachment Kenai · USCG Arctic District (CGD-A) · Activity 3386
14 October 1992 Type not recorded
No type recorded · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 226434
2 April 1992 Type not recorded
No type recorded · MSO ANCHORAGE · USCG Arctic District (CGD-A) · Activity 958903
10 March 1992 Type not recorded
No type recorded · MSO ANCHORAGE · USCG Arctic District (CGD-A) · Activity 1009919
5 September 1991 COI Inspection
Physical examination · MSO ANCHORAGE · USCG Arctic District (CGD-A) · Activity 941609
27 August 1991 Type not recorded
No type recorded · Marine Safety Detachment Kenai · USCG Arctic District (CGD-A) · Activity 656025
9 August 1991 Type not recorded
No type recorded · Marine Safety Detachment Kenai · USCG Arctic District (CGD-A) · Activity 656024
3 April 1991 Type not recorded
No type recorded · MSO ANCHORAGE · USCG Arctic District (CGD-A) · Activity 905308
21 January 1991 Deficiency Check
Physical examination · MSO ANCHORAGE · USCG Arctic District (CGD-A) · Activity 1211627
6 November 1990 Re-Inspection
Physical examination · MSO ANCHORAGE · USCG Arctic District (CGD-A) · Activity 913422
8 May 1990 Hull Examination
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 903271
8 February 1990 Administrative
Administrative · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1227224
23 January 1990 Type not recorded
No type recorded · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 977794
20 September 1989 COI Inspection · Hull Examination
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 903028
14 October 1988 Re-Inspection
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 888655
29 February 1988 Administrative
Administrative · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1026115
10 November 1987 Administrative
Administrative · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1330743
1 November 1987 Administrative
Administrative · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1329621
14 October 1987 COI Inspection · Hull Examination
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1016933
30 June 1987 Administrative
Administrative · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1009008
12 March 1985 Type not recorded
No type recorded · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 981756

Deficiency record · 72

Lifesaving › Embarkation Appliances/Stations › Accessability
Issued 25 November 1997 Resolved
RENEW EXPIRED LIFEBOAT PYROTECHNICS IN WAY OF LIFEBOAT #1.
Condition: Unknown
Due 25 February 1998
Resolved 14 March 2005
Resolution: Vessel reflaged
Fire Fighting › Fixed Deck Foam System › Valves
Issued 25 November 1997 Resolved
PROVIDE A COPY OF THE FOAM ANALYSIS REPORT TO THE [name withheld], TAKEN ON ALL FIXED FOAM SYSTEMS.
Condition: Unknown
Due 25 February 1998
Resolved 14 March 2005
Resolution: Vessel reflaged
Lifesaving › Launching Appliances › Falls
Issued 25 November 1997 Resolved
CONDUCT HYDROSTATIC TESTING OF ALL THE RIG'S AIR RECEIVERS (10) IN THE PRESENCE OF COAST GUARD OR ABS SURVEYOR.
Condition: Unknown
Due 25 February 1998
Resolved 14 March 2005
Resolution: Vessel reflaged
Navigation › Collision/Grounding Avoidance › Navigation Lights
Issued 25 November 1997 Resolved
INSTALL MAST AND MAST HEAD LIGHT PRIOR TO NEXT BARGE MOVE OR NO LATER THAN THE INDICATED COMPLIANCE DATE.
Condition: Unknown
Due 25 February 1998
Resolved 14 March 2005
Resolution: Vessel reflaged
Deck/Cargo › Holds/Tanks › Bulkhead
Issued 25 November 1997 Resolved
MAKE REPAIRS TO THE DAMAGE NOTED AT DERRICK, THIRD HORIZONTAL TRANSVERSE BEAM OF THE FORWARD SIDE OF THE SERRICK; DISTORTED AT MIDSECTION. BOLT HOLES MUST BE APPROPRIATELY NTD PRIOR TO INSTALLING NEW BEAM. ABS MUST APPROVE REPAIR AND TESTING PROCEDURE OF DAMAGED AREA.
Condition: Unknown
Due 25 February 1998
Resolved 14 March 2005
Resolution: Vessel reflaged
Lifesaving › Inflatable Liferafts › Approval
Issued 25 November 1997 Resolved
CONDUCT ANNUAL SERVICING OF THE #2 LIFE RAFT (25 PERSON CREWSAVER) AT A COAST GUARD APPROVED SERVICING STATION. THE OIM MUST ENSURE THE SERVICING FACILITY MEETS THE PROVISIONS OF 46CFR160.151-53.
Condition: Unknown
Due 25 February 1998
Resolved 14 March 2005
Resolution: Vessel reflaged
Fire Fighting › Portable CO2 Fire Extinguisher › Approval
Issued 25 November 1997 Resolved
COMPLETE PORFESSIONAL SERVICING OF ALL FIXED, SEMI-PORTABLE AND PORTABLE FIRE EXTINGUISHING EQUIPMENT AND FIRE/GAS DETECTION SYSTEMS ON THE RIG. ATCOMPLETION, PROVIDE A COPY OF THE SERVICING REPORT TO THE [name withheld].
Condition: Unknown
Due 25 February 1998
Resolved 14 March 2005
Resolution: Vessel reflaged
Engineering › Fuel Oil Service System › Tank
Issued 25 November 1997 Resolved
RENEW/REPAIR THE HELICOPTER REFUELLING TANK (SPARE UNIT) RELIEF VALVE AND VENT PRIOR TO OPERATING SAME BUT NOT LATER THAN THE COMPLIANCE DATE INDICATED.
Condition: Unknown
Due 25 February 1998
Resolved 21 March 2005
Resolution: Vessel reflaged
Construction/Loadline › Hull › Bottom Plating
Issued 25 November 1997 Resolved
MAKE PERMANENT REPAIRS TO THE SEALS IN WAY OF PRELOAD TANKS ONE AND TWO.
Condition: Unknown
Due 25 February 1998
Resolved 14 March 2005
Resolution: Vessel reflaged
Lifesaving › Buoyant Apparatus › Marking
Issued 25 November 1997 Resolved
APPLY RETRO-REFLECTIVE TAPE/MATERIAL TO RING BUOYS NOTED DEFICIENT DURING THE ABS SURVEY COMPLETED 25NOV97.
Condition: Unknown
Due 25 February 1998
Resolved 14 March 2005
Resolution: Vessel reflaged
Lifesaving › Buoyant Apparatus › Marking
Issued 25 November 1997 Resolved
RENEW THE RING BUOY LOCATED ON THE PORT BOW.
Condition: Unknown
Due 25 February 1998
Resolved 14 March 2005
Resolution: Vessel reflaged
Fire Fighting › Miscellaneous Items › A Class Division Penetrations
Issued 25 November 1997 Resolved
MAKE PERMANENT REPAIRS TO THE PULLEY SHEAVE COUNTER WEIGHT IN WAY OF THE PORT SIDE SACK ROOM FIRE DAMPER.
Condition: Unknown
Due 25 February 1998
Resolved 14 March 2005
Resolution: Vessel reflaged
Construction/Loadline › Penetrations › Gasket
Issued 25 November 1997 Resolved
MAKE PERMANENT REPAIRS/ADJUSTMENTS TO THE WATERTIGHT DOORS NOTED IN ABS SURVEY REPORT DTD 25NOV97 THROUGHOUT THE RIG.
Condition: Unknown
Due 25 February 1998
Resolved 14 March 2005
Resolution: Vessel reflaged
Accommodation/Occupational Safety › Washroom/Toilet › Location
Issued 25 November 1997 Resolved
MAKE PERMANENT REPAIRS TO THE VENT FROM HEADS. IN PARTICULAR SEALS, SEAL CHANNELS AND COAMING.
Condition: Unknown
Due 25 February 1998
Resolved 14 March 2005
Resolution: Vessel reflaged
Accommodation/Occupational Safety › Other Accommodation Spaces › Recreation Space
Issued 25 November 1997 Resolved
PROVIDE BUNK LIGHTS AND LOCKERS FOR CREW LOCATED IN THE CONVERTED RECREATION ROOM/GYMNASIUM. OIM IS TO ENSURE THE PORVISIONS OF 46CFR108.201ARE MET.
Condition: Unknown
Due 25 February 1998
Resolved 14 March 2005
Resolution: Vessel reflaged
Documentation › Certificates/Documents › Document of Authorization (grain)
Issued 25 November 1997 Resolved
PROVIDE THE STCW ENDORSEMENT FOR THE BARGE MASTER'S LICENSE._x001C_
Condition: Unknown
Due 9 January 1998
Resolved 9 January 1998
Resolution: Vessel reflaged
Lifesaving › Lifeboat › Canopy
Issued 25 November 1997 Resolved
MAKE PERMANENT REPAIRS TO THE NUMBER 1 LIFEBOAT IN WAY OF THE CANOPY, STARBOARD SIDE.
Condition: Unknown
Due 25 February 1998
Resolved 14 March 2005
Resolution: Vessel reflaged
Lifesaving › Launching Appliances › Falls
Issued 25 November 1997 Resolved
RENEW THE FALLS IN WAY OF LIFEBOATS 1 AND 2. CONDUCT A WEIGHT TEST OF THE FALLS AND PROVIDE A DOCMUMENT ATTESTING TO THE RENEWAL AND TESTING SIGNED BY THE OIM.
Condition: Unknown
Due 25 February 1998
Resolved 14 March 2005
Resolution: Vessel reflaged
Accommodation/Occupational Safety › Washroom/Toilet › Shower/Bathtub
Issued 25 November 1997 Resolved
MAKE PERMANENT REPAIRS TO THE CREW SHOWER VALVE AS IDENTIFIED IN ABS REPORTDTD 25NOV97, ITEM 8.
Condition: Unknown
Due 25 February 1998
Resolved 14 March 2005
Resolution: Vessel reflaged
Lifesaving › Lifeboat Equipment › Boat Hook
Issued 25 November 1997 Resolved
FOR LIFEBOAT #1, PROVIDE THE FOLLOWING EQUIPEMENT: CAN OPENER (UNLESS ONE IS INCORPORATED IN A JACKNIFE) AND THERMAL PROTECTIVE AIDS FOR 10% OF THE BOAT'S CAPACITY.
Condition: Unknown
Due 25 February 1998
Resolved 14 March 2005
Resolution: Vessel reflaged
Documentation › Certificates/Documents › Cargo Ship Safety Certificate
Issued 25 November 1997 Resolved
MAKE ARRANGEMENTS WITH THE ABS PRINCIPAL SURVEYOR IN NIGERIA TO CONDUCT AN IOPP SURVEY ON BEHALF OF THE FLAG STATE: U.S. COAST GUARD.
Condition: Unknown
Due 25 February 1998
Resolved 14 March 2005
Resolution: Vessel reflaged
Engineering
Issued 12 October 1994 Resolved
Provide evidence of current hydrostatic testing of all fuel transfer hoses.Hoses shall not be used for transfers until satisfactory completion of thisrequirement.
Condition: Unknown
Due 12 October 1994
Resolved 12 October 1994
Construction/Loadline
Issued 12 October 1994 Resolved
Provide MSO Anchorage with entire NDT report when furnished by CTI.
Condition: Unknown
Due 12 October 1994
Resolved 12 October 1994
Lifesaving
Issued 12 October 1994 Resolved
Provide two additional immersion suits. Vessel is limited to 88 maximum persons allowed.
Condition: Unknown
Due 12 October 1994
Resolved 12 October 1994
Construction/Loadline
Issued 12 October 1994 Resolved
Provide evidence of final 72 hour NDT of repairs to cord "C" 16' to 20' andcord "D" 16' to 20'. Vessel shall not spud down until this requirement is completed.
Condition: Unknown
Due 12 October 1994
Resolved 12 October 1994
Electrical
Issued 12 October 1994 Resolved
Install cover to galley stores light fixture.
Condition: Unknown
Due 12 October 1994
Resolved 12 October 1994
Accommodation/Occupational Safety
Issued 12 October 1994 Resolved
Make permanent repairs to Marine Sanitation device.
Condition: Unknown
Due 15 October 1994
Resolved 15 October 1994
Lifesaving
Issued 19 October 1993 Resolved
PROVIDE CABLE PULL TEST DATA FOR NEW CABLE WITH DAVIT FITTING ON PORT AND STARBOARD RAFT DAVITS OR CONDUCT SATISFACTORY WEIGHT TEST OF SAME, PER _x001C_ 46 CFR 107.239.
Condition: Unknown
Due 21 October 1993
Resolved 21 October 1993
Deck/Cargo
Issued 11 December 1992 Resolved
REPLACE DEFECTIVE EXPANSION JOINT ON DRILL WATER PUMPSS PER 46 CFR 58
Condition: Unknown
Due 11 December 1992
Resolved 11 December 1992
Construction/Loadline
Issued 11 December 1992 Resolved
MAKE AVAILABLE FOR INSPECTION THE DEUMP VALVES IN PRELOAD TANKS #37-38.
Condition: Unknown
Due 11 December 1992
Resolved 11 December 1992
Construction/Loadline
Issued 11 December 1992 Resolved
PROVE PROPER OPERATION OF THE CHECK VALVES ON PRELOAD TANK #35 DUMP VALVE.
Condition: Unknown
Due 11 December 1992
Resolved 11 December 1992
Engineering
Issued 11 December 1992 Resolved
PROVE PROPER OPERATION OF THE OIL WATER SEPERATOR AND THE CG TO ENSURE THATTHE IOPP CERTIFICATE PER MARPOL II.
Condition: Unknown
Due 11 December 1992
Resolved 11 December 1992
Deck/Cargo
Issued 11 December 1992 Resolved
PROVIDE LIFTING CAPACITY FOR THE POWERED INDUSTRIAL TRUCK PER 46 CFR 109.533.
Condition: Unknown
Due 11 December 1992
Resolved 11 December 1992
Fire Fighting
Issued 11 December 1992 Resolved
PROVIDE RELIEF VALVES ON THE FIRE PUMPS FOR THE FIRE MAIN SET AT 125PSI PER46 CFR 108.417.
Condition: Unknown
Due 11 December 1992
Resolved 11 December 1992
Engineering
Issued 11 December 1992 Resolved
PROVE PROPER OPERATION OF THE LOSS OF LOUBE OIL AUTO SHUTDOWN ON THE #3 S/SGEN PER 46 CFR 111.12.
Condition: Unknown
Due 11 December 1992
Resolved 11 December 1992
Accommodation/Occupational Safety
Issued 11 December 1992 Resolved
MAKE AVAILABLE FOR INSPECTION THE DRILL FLOOR AND SHAKER AREA PRIOR TO COMMENCING DRILLING OPERATIONS.
Condition: Unknown
Due 11 December 1992
Resolved 11 December 1992
Fire Fighting
Issued 11 December 1992 Resolved
PROVIDE REPORT OR DEMONSTRATE THAT ALL THE DISCREPENCIES NOTED ON THE FIREFIGHTING REPORT HAVE BEEN CORRECTED.
Condition: Unknown
Due 11 December 1992
Resolved 11 December 1992
Lifesaving
Issued 2 April 1992 Resolved
VESSEL LIMITED TO NO MORE THAN 75 TOTAL PERSONS UNTIL LIFERAFT SENT FOR SERVICING IS RETURNED AND PROPERLY INSTALLED.
Condition: Unknown
Due 2 April 1992
Resolved 2 April 1992
Fire Fighting
Issued 6 November 1990 Resolved
REPAIR TO MAKE OPERABLE OR REPLACE THE AUTO CLOSURES ON ALL DOORS IN FIRE BOUNDRY BULKHEADS, AND ENSURE THAT ANY HOLD BACK DEVICES ON THESE DOORS AREREMOVED.
Condition: Unknown
Due 6 November 1990
Resolved 6 November 1990
Fire Fighting
Issued 6 November 1990 Resolved
PROVE THAT BOTH FIRE PUMPS OPERATE AT REQUIRED DISCHARGE PRESSURE WHEN THE VESSEL IS AFLOAT USING SEA SUCTION.
Condition: Unknown
Due 6 November 1990
Resolved 6 November 1990
Unknown
Issued 6 November 1990 Resolved
PROVIDE CG APPROVED PLANS FOR THE NEWLY INSTALLED HEATING UNITS FOR THE DOUBLE BOTTOM WATER TANKS.
Condition: Unknown
Due 6 November 1990
Resolved 6 November 1990
Fire Fighting
Issued 6 November 1990 Resolved
MAKE PERMANENT AND PROPER REPAIRS TO THE FIRE MAIN SYSTEM WHERE PATCHS HAVEBEEN WELDED TO THE PIPING IN THE VICINITY OF THE PUMPS AND DISCHARGE MAN- IFOLD VALVES AND PIPING. REPAIRS TO BE FOLLOWED BY A 1.5 X MAWP OF THE ENTIRE FIREMAIN SYSTEM.
Condition: Unknown
Due 6 November 1990
Resolved 6 November 1990
Construction/Loadline
Issued 6 November 1990 Resolved
REPAIR AND REPLACE FLAME SCREENS ON TANK VENTS AS NECESSARY THROUGHOUT THE VESSEL.
Condition: Unknown
Due 6 November 1990
Resolved 6 November 1990
Fire Fighting
Issued 6 November 1990 Resolved
PROVIDE EVIDENCE THAT THE CORAL FLEX FIRE HOSE IS APPROVED FOR USE ON BOARDTHE VESSEL.
Condition: Unknown
Due 6 November 1990
Resolved 6 November 1990
Fire Fighting
Issued 6 November 1990 Resolved
REPAIR OR REPLACE THE PRESSURE GAUGE ON THE DISCHARGE SIDE OF THE FIRE MAINREDUCING STATION AT NO. 1 FIRE PUMP.
Condition: Unknown
Due 6 November 1990
Resolved 6 November 1990
Lifesaving
Issued 6 November 1990 Resolved
PROVIDE A CHAIN SUSPENSION LADDER FOR THE PORT LIFE BOAT.
Condition: Unknown
Due 6 November 1990
Resolved 6 November 1990
Fire Fighting
Issued 6 November 1990 Resolved
INVENTORY, CHECK, AND DO NECESSARY MAINTENANCE ON BOTH FIREMAN'S OUTFITS. THE BOX FWD OF THE CONTROL ROOM NEEDS TO BE PERMANENTLY FASTENED DOWN.
Condition: Unknown
Due 6 November 1990
Resolved 6 November 1990
Electrical
Issued 6 November 1990 Resolved
REWIRE THE H2S ALARM PANEL IN THE SCR ROOM, USING PROPER WIRING METHODS ANDMATERIAL.
Condition: Unknown
Due 6 November 1990
Resolved 6 November 1990
Construction/Loadline
Issued 6 November 1990 Resolved
REPLACE THE CRACKED WINDOW IN THE RIG SUPERINTENDENTS OFFICE.
Condition: Unknown
Due 6 November 1990
Resolved 6 November 1990
Unknown
Issued 6 November 1990 Resolved
PROVIDE A PROPER TYPE AND PRESSURE (ASME) RELIEF VALVE ON NO.5 BARITE TANK.
Condition: Unknown
Due 6 November 1990
Resolved 6 November 1990
Electrical
Issued 6 November 1990 Resolved
INSTALL GENERAL ALARM BELLS IN THE SHALE SHAKER AND ON THE BOW, ENSURING THAT ALL BELLS ON BOARD THE VESSEL ARE MARKED AND OPERABLE.
Condition: Unknown
Due 6 November 1990
Resolved 6 November 1990
Lifesaving
Issued 6 November 1990 Resolved
REPLACE THE WATER LIGHT FOR THE PORT AFT LIFE RING.
Condition: Unknown
Due 6 November 1990
Resolved 6 November 1990
Lifesaving
Issued 6 November 1990 Resolved
PROVIDE NEW COAXIL CABLE FOR THE ANTENNA FOR THE PORTABLE LIFEBOAT RADIO.
Condition: Unknown
Due 6 November 1990
Resolved 6 November 1990
Construction/Loadline
Issued 6 November 1990 Resolved
CLEAN AND REPAIR AS NECESSARY THE VENT CLOSURE FOR THE PAINT LOCKER.
Condition: Unknown
Due 6 November 1990
Resolved 6 November 1990
Construction/Loadline
Issued 6 November 1990 Resolved
REMOVE THE SOFT PATCH THAT HAS BEEN PLACED ON THE BILGE PIPING AT THE INLETTO THE EDUCTOR, REPLACE PIPING AS NECESSARY, AND TEST THE SYSTEM FOLLOWING NECESSARY REPAIRS.
Condition: Unknown
Due 6 November 1990
Resolved 6 November 1990
Electrical
Issued 6 November 1990 Resolved
THE INSULATION ON NUMEROUS WELDING LEAD PIGTAILS HAS SEPERATED FROM THE WIRE, EXPOSING THE WIRE, PIGTAILS REQUIRE REPLACING.
Condition: Unknown
Due 6 November 1990
Resolved 6 November 1990
Electrical
Issued 20 September 1989 Resolved
PROVIDE PROPER OPERATION TO GENERATOR NUMBER (3) THREE FOR THE OVERSPEED TRIP AND LOW LUBE OIL PRESSURE ALARM AND TRIP, PRIOR TO DRILLING OPERATIONSCOMPLIANCE DATE BY 01-01-90
Condition: Unknown
Due 20 September 1989
Resolved 20 September 1989
Lifesaving
Issued 20 September 1989 Resolved
HAVE VESSELS LIFEBOAT AIR BOTTLES AND SELF CONTAINED BREATHING APPARATUS AND CO2 BOTTLES HYDROSTATICALLY TESTED OR PROVE TESTING WAS DONE IN ACCORDANCE WITH CFR 46-147.04-1(A)(4) AND 39 CFR 173.34.
Condition: Unknown
Due 20 September 1989
Resolved 20 September 1989
Electrical
Issued 14 October 1988 Resolved
REPIAR OR REPLACE SWITCH BOX COVER ON MOTOR CONTROLLER IN SHALE SHAKER ROOMPRIOR TO OPERATING SYSTEM.
Condition: Unknown
Due 14 October 1988
Resolved 14 October 1988
Fire Fighting
Issued 14 October 1988 Resolved
CONDUCT ANNUAL SERVICING OF FIXED (HALON) AND SEMI-PORTABLE (DC) FIRE EXTINGUISHING SYSTEMS.
Condition: Unknown
Due 14 October 1988
Resolved 14 October 1988
Fire Fighting
Issued 14 October 1988 Resolved
PERFORM HYDROSTATIC TESTS OF PORTABLE CO2 FIRE EXTINGUISHER BOTTLES OR REPLACE WITH BOTTLES BEARING VALID HYDROSTATIC TEST DATE (FIVE YEAR).
Condition: Unknown
Due 14 October 1988
Resolved 14 October 1988
Lifesaving
Issued 14 October 1988 Resolved
HAVE BREATHING AIR BOTTLES IN SURVIVAL CAPSULES. HYDROSTATICALLY TESTED.
Condition: Unknown
Due 14 October 1988
Resolved 14 October 1988
Fire Fighting
Issued 14 October 1988 Resolved
HAVE AIR BOTTLES IN SELF-CONTAINED BREATHING APPARATUS. HYDROSTATICALLY TESTED.
Condition: Unknown
Due 14 October 1988
Resolved 14 October 1988
Lifesaving
Issued 14 October 1987 Resolved
FOR THE ROCKET LINE THROWING APPLIANCE, PROVIDE FOUR ROCKETS, TWO OF WHICH MUST BE BUOYANT AND AT LEAST FOUR PROJECTILE PRIMER CARTRIDGES. THE ROCKETSAND CARTRIDGES CURRENTLY ABOARD ARE OUTDATED (46 CFR 160.040). THIS REQUIREMENT MUST BE COMPLETED PRIOR TO PLACING THE THE MODU IN SERVICE.
Condition: Unknown
Due 14 October 1987
Resolved 14 October 1987
Unknown
Issued 14 October 1987 Resolved
PROVIDE A READABLE METAL INFORMATION PLATE FOR THE TWO MARINE PORTABLE TANKS USED FOR HELICOPTER FUEL (46 CFR 64.53).
Condition: Unknown
Due 14 October 1987
Resolved 14 October 1987
Unknown
Issued 14 October 1987 Resolved
FOR THE TWO MARINE PORTABLE TANKS USED FOR HELICOPTER FUELLING; CONDUCT THETESTS AND INSPECTIONS REQUIRED BY 46 CFR 64.77. THESE REQUIREMENTS IN 46 CFR 64.77 MAY BE DONE BY VESSEL PERSONNEL AND APPROPRIATE RECORDS MADE IN THE RIG'S RECORDS.THIS REQUIREMENT MUST BE COMPLETED PRIOR TO PLACING HELO
Condition: Unknown
Due 14 October 1987
Resolved 14 October 1987
Unknown
Issued 14 October 1987 Resolved
PROVIDE IN WRITING A PLAN FOR THE DAMAGE NOTED TO THE BOTTOM OF ALL CORDS: THE DEFORMED SHEER WAS ON THE BOW CAN AT THE AFTER STARBOARD CORD AND THE DAMAGE TO THE SPUD TANK IN BOARD OF THE AFTER STARBOARD CORD. THIS PLAN SHALL INCLUDE AN EVALUATION BY THE DESIGNER OF THE GLOMAR ADRIATIC VIII AS
Condition: Unknown
Due 14 October 1987
Resolved 14 October 1987
Unknown
Issued 14 October 1987 Resolved
PROVE PROPER OPERATION OF H2S AND GAS DETECTION UNITS. SPAN GAS WAS UNAVAILABLE FOR CALIBRATION AND TESTING. THIS REQUIREMENT WAS PREVIOUSLY ISSUED AS CG-835 ITEM D1 DTD 12 MARCH 1985.
Condition: Unknown
Due 14 October 1987
Resolved 14 October 1987
Lifesaving
Issued 14 October 1987 Resolved
FOLLOWING THE INSTRUCTIONS IN THE WHITAKER SURVIVAL CAPSULE REPAIR MANUAL, REPAIR THE NINE INCH CRACK LOCATED 12 INCHES TO PORT OF THE DISENGAGING APPARTUS IN THE OVERHEAD OF THE NUMBER 1 SURVIVAL CAPSULE. 46 CFR 108.503 (G)(3).
Condition: Unknown
Due 14 October 1987
Resolved 14 October 1987
Lifesaving
Issued 14 October 1987 Resolved
FOR EACH SURVIVAL CAPSULE, PROVIDE THE FOLLOWING: ONE JACKNIFE, 12 HAND HELD RED PARACHUTE FLARES AND 150 QUARTS OF WATER (46 CFR 108.503(F). THIS REQUIREMENT MUST BE COMPLETED PRIOR TO PLACING THE MODU IN SERVICE.
Condition: Unknown
Due 14 October 1987
Resolved 14 October 1987
Lifesaving
Issued 14 October 1987 Resolved
PROVIDE FOUR COMPLETELY SERVICED 25 MAN DAVIT LAUNCHED 25 MAN LIFERAFTS (46 CFR 108.505).THIS REQUIREMENT MUST BE COMPLETED PRIOR TO PLACING THE MODU IN SERVICE.
Condition: Unknown
Due 14 October 1987
Resolved 14 October 1987
Unknown
Issued 12 March 1985 Resolved
PROVE PROPER OPERATION OF GAS DETECTION AND H2S UNITS.
Condition: Unknown
Due 12 March 1985
Resolved 12 March 1985

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.