MCDERMOTT DERRICK BARGE NO. 26
MCDERMOTT DERRICK BARGE NO. 26 is a 1975 industrial vessel. The Coast Guard has recorded 17 inspections since 1985, most recently in December 1989, along with 29 deficiencies.
Records from 1985 to 1989. Most recent: inspection, 14 December 1989.
- Built
- 1975
- Last inspected
- 14 December 1989
- Documentation
- Not in the documentation file of 10 September 2026
- Deficiencies
- 29 recorded · 0 without a recorded resolution
- Controls
- None recorded without a removal date
Identity
565376
54962
Flag
UNITED STATES
—
Maury page id
psix-54962
Inspections, by type
…with no type recorded2
Years with a record
5 calendar years (1985–1989)
The 17 inspections in the strip above, split by the kind of activity the US
Coast Guard recorded. Years with a record are calendar years in which a record exists, not
years in service. What Maury does not do.
This record may be incomplete: the most recent inspection recorded for this vessel was 37 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Barge class in Maury's sources begin in 1972.
Documentation record
Tonnage as PSIX records it8327 - Regulatory (Subpart C or D), Gross Ton
6101 - Regulatory (Subpart C or D), Net Ton
6101 - Regulatory (Subpart C or D), Net Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.
Radio station licence
No FCC ship-station licence is recorded against this Official Number in the file of
6 September 2026. That is a fact about the licence file, not about the radio.
Inspection history · 17
14 December 1989
Administrative
Administrative · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1219112
9 January 1989
Deficiency Check
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1349937
9 December 1988
COI Inspection
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1037812
10 December 1987
Administrative
Administrative · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1001934
19 November 1987
Administrative
Administrative · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1336142
27 July 1987
COI Inspection · Hull Examination
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1030469
4 July 1987
MARPOL Annex II Examination
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1030795
13 February 1987
Deficiency Check
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1020576
6 January 1987
Administrative
Administrative · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1314581
2 December 1986
Administrative
Administrative · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1023591
17 November 1986
Administrative
Administrative · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1015606
27 October 1986
Re-Inspection
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1019553
8 October 1985
Type not recorded
No type recorded · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1301195
3 October 1985
COI Inspection
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 987218
31 August 1985
Credit Drydock
Administrative · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 987217
12 August 1985
Deficiency Check
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1291868
31 March 1985
Type not recorded
No type recorded · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1287731
Deficiency record · 29
Electrical
Issued 9 December 1988
Resolved
PROVE PROPER OPERATION OF GENERAL ALARMS IN RADIO ROOM AND EXPAT. GALLEY.
Engineering
Issued 9 December 1988
Resolved
PROVE PROPER OPERATION OF BOILER LOW WATER SAFETY SWITCH.
Engineering
Issued 9 December 1988
Resolved
PROVIDE APPROVED PLANS TO [name withheld] FOR THE AIR COMPRESSOR, PIPING AND AIR RECEIVERS USED IN THE DIVING AIR SYSTEM.
Documentation
Issued 9 December 1988
Resolved
CHANGE THE HAILING PORT ON VESSEL AND RING BUOYS TO EITHER THE HOMEPORT OR THE OWNERS ADDRESS (NEW ORLEANS, LA)
Fire Fighting
Issued 27 July 1987
Resolved
REPLACE PRESENT PLYWOOD CONSTRUCTED DOORS LEADING FROM THE OPEN DECK TO THEBARGE OFFICES ON PORT SIDE WITH APPROVED METAL DOOR.
Engineering
Issued 27 October 1986
Resolved
UPON INSTALLATION OF NEW OILY WATER SEPARATOR PROVE OPERATION.
Engineering
Issued 27 October 1986
Resolved
CONDUCT INTERNAL AND EXTERNAL EXAMINATION OF AUXILIARY BOILER (JOHNSTON). CONDUCT HYDROSTATIC TEST. OPERATIONAL TEST AND TEST RELIEF VALVES.
Construction/Loadline
Issued 27 October 1986
Resolved
REPLACE WASTED DECK PLANKING.
Lifesaving
Issued 27 October 1986
Resolved
REPAIR HOLES IN SAFETY NETTING AROUND ENTIRE PERIMETER OF HELICOPTER DECK.
Fire Fighting
Issued 27 October 1986
Resolved
PROVIDE COVER FOR FIXED NATURAL VENTILATION ON PAINT LOCKER TO CONFORM TO 46 CFR 95-15-35(C).
Fire Fighting
Issued 27 October 1986
Resolved
PROVIDE CALIBRATION TEST GAS FOR OXYGEN/COMBUSTIBLE GAS METER AND PROVE PROPER OPERATION.
Lifesaving
Issued 27 October 1986
Resolved
CONDUCT ANNUAL SERVICING OF INFLATABLE LIFE RAFT HYDROSTATIC RELEASES (13).
Fire Fighting
Issued 27 October 1986
Resolved
PROVIDE ADDITIONAL 150 POUNDS OF FIXED CO2 FOR PAINT LOCKER (4352 CUBIC FEET) TO COMPLY WITH 46 CFR 95-15-5(E).
Fire Fighting
Issued 27 October 1986
Resolved
REPAIR OR REPLACE AFT FIRE PUMP AND PROVE PROPER OPERATION.
Fire Fighting
Issued 27 October 1986
Resolved
REPLACE 4 50' 1 1/2" FIRE HOSES WITH 4 75' 1 1/2" U.S. COAST GUARD APPROVEDFIRE HOSES AS PER MCDERMOTT FIRE CONTROL PLAN.
Fire Fighting
Issued 27 October 1986
Resolved
REPLACE OR RE-HYDRO ALL DRY CHEMICAL CHARGING CYLINDERS THROUGHOUT VESSEL THAT HAVE HYDRO DATE 12 YEARS OR OLDER.
Construction/Loadline
Issued 3 October 1985
Resolved
PROVIDE [name withheld] PLANS OR LETTER FROM US COAST GUARD OF THE NEW INSTALLED SEA CHEST, OR VERIFY APPROVAL OF ORIGINAL PLAN M-603.
Unknown
Issued 3 October 1985
Resolved
PROVE PROPER OPERATION OF VESSEL'S OILY WATER SEPERATOR.
Deck/Cargo
Issued 31 March 1985
Resolved
AMERICAN DERRICK AND MAINTENANCE CRANE SHALL BE TESTED IN ACCORDANCE WITH 46CFR91.37 AND REPORTS SUBMITTED FOR REVIEW.
Fire Fighting
Issued 31 March 1985
Resolved
THE VESSEL FIRE CONTROL/SAFETY EQUIPMENT DRAWING SHALL BE SUBMITTED FOR REVIEW AND APPROVAL.
Lifesaving
Issued 31 March 1985
Resolved
LIFERAFT STATIONS 5,6,7 AND 10 SHALL BE FITTED WITH MEANS FOR EMBARKATION.
Fire Fighting
Issued 31 March 1985
Resolved
FIRE STATION NUMBERS 2,3,12,16,17 AND 18 SHALL BE PROVIDED WITH COAST GUARDAPPROVED COMBINATION NOZZLES.
Accommodation/Occupational Safety
Issued 31 March 1985
Resolved
SERVICE ELEVATOR SAFETY RETAINING GATE SHALL BE REINSTALLED. CERTIFICATE OF MANUFACTURE, TEST AND INSPECTION RECORDS SHALL BE PROVIDED FOR COAST GUARD REVIEW.
Accommodation/Occupational Safety
Issued 31 March 1985
Resolved
THE VESSELS OILY WATER SEPERATOR SHALL BE REPAIRED AND A STANDARD DISCHARGE CONNECTION INSTALLED.
Fire Fighting
Issued 31 March 1985
Resolved
PLANS AND DETAILS FOR THE INSTALLATION OF A FIXED FIRE FIGHTING SYSTEM TO BE INSTALLED IN THE MAIN CRANE MACHINERY SPACE SHALL BE SUBMITTED.
Electrical
Issued 31 March 1985
Resolved
GENERAL ALARM BELLS SHALL BE INSTALLED IN THE MAIN CRANE MACHINERY SPACE, CONTROL CAB AND FORWARD MODULAR ACCOMIDATIONS.
Fire Fighting
Issued 31 March 1985
Resolved
THE HELICOPTER LANDING DECK SHALL BE PROVIDED WITH ONE ADDITIONAL COAST GUARD APPROVED BV FIRE EXTINGUISHER.
Fire Fighting
Issued 31 March 1985
Resolved
THE 13 CO2 BOTTLES SERVING THE PORT WINCH ROOM AND ONE CO2 BOTTLE SERVING THE PAINT LOCKER SHALL BE HYDROTESTED, FILLED AND REINSTALLED. ALL FLEX LOOPS (40 TOTAL) SHALL BE TESTED HYDROSTATICALLY.
Electrical
Issued 31 March 1985
Resolved
HEAT DEFLECTING SHIELDS SHALL BE INSTALLED ON THE RACOR FUEL FILTERS IN THE GENERATOR ROOM.