Records from 2003 to 2025. Most recent: inspection, 19 December 2025.
Inspection history · 24
19 December 2025
Internal Structural Exam · COI Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 8278305
14 August 2025
In-Service Inspection
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 8213519
9 June 2025
Annual Inspection
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 8155810
31 March 2025
Drydock Exam · Internal Structural Exam
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 8099409
7 February 2025
Administrative Inspection
Administrative · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 8079581
13 June 2024
Annual Inspection
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 7923182
8 June 2023
Annual Inspection
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 7685333
2 February 2023
Plan Review "T" Boat
Administrative · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 7631669
8 November 2022
Drydock Exam · Internal Structural Exam · Examination of Repairs
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 7588119
4 April 2022
Deficiency Check · COI Inspection
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 7407118
15 June 2021
Annual Inspection
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 7219643
26 May 2021
Deficiency Check
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 7208572
6 May 2021
Drydock Exam · Examination of Repairs · Internal Structural Exam
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 7184958
25 June 2020
DAPI Audit · Annual Inspection · Administrative Inspection · Deficiency Check
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 6967994
28 June 2019
DAPI Audit · Annual Inspection
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 6719307
1 April 2019
Drydock Exam · Internal Structural Exam
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 6648504
8 May 2018
DAPI Audit · Deficiency Check · Annual Inspection
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 6397394
18 May 2017
Examination of Repairs · Internal Structural Exam · Drydock Exam
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 6143906
4 April 2017
COI Inspection · DAPI Audit
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 6111082
25 August 2016
Deficiency Check
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 6038481
17 June 2016
Annual Inspection · DAPI Audit
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 5906237
2 June 2016
Type not recorded
No type recorded · Station Point Judith · USCG Northeast District (CGD-NE) · Activity 5896003
2 June 2016
Type not recorded
No type recorded · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 5907109
2 June 2016
Deficiency Check · Damage Survey
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 5933980
01 - Certificates & Documentation › 011 - Ships Certificates › Other (certificates)
Issued 19 December 2025
Resolved
The Master Shall conduct drills and give instructions as necessary to ensure that all the crew members are familiar with their duties. Owner shall conduct boat & fire drills in the presence of marine inspector prior to carrying passengers.
46 CFR 185.25-10 OLD T
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 6 March 2026
Resolution: Completed satisfactory man overboard drill and tabletop fire drill.
01 - Certificates & Documentation › 011 - Ships Certificates › Other (certificates)
Issued 19 December 2025
Resolved
Full DAPI Audit to be completed prior to carrying passengers. Owner to schedule an audit of the files to ensure full compliance with Subchapter B.
46 CFR Part 16
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 11 March 2026
Resolution: Recieved final item that was outstanding (EAP) which is posted on the bridge.
01 - Certificates & Documentation › 011 - Ships Certificates › Other (certificates)
Issued 19 December 2025
Resolved
Any vessel of at least 5 NRT must have a COD. Owner to obtain valid COD.
46 CFR 67.7
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 27 January 2026
Resolution: Recieved pictures of valid COD from Owner.
01 - Certificates & Documentation › 012 - Crew Certificates › Certificate for medical care
Issued 19 December 2025
Resolved
Each officer employed on any vessel must have his/her license and available for inspection at all times. O/O shall provide for valid medical certificate.
46 CFR 185.402
Action required: 705 - Other - as specified
Resolved 23 January 2026
Resolution: Owner submitted photo copy of their valid medical certificate.
10 - Safety of Navigation › N/A - No Subsystem › Other (navigation)
Issued 19 December 2025
Resolved
Anchor light was found inoperable at the time of inspection. Renew as appropriate prior to operations during period of low visibility.
46 CFR 96
Action required: 705 - Other - as specified
Resolved 20 January 2026
Resolution: Owner submitted pictures of fixed anchor light.
11 - Life Saving Appliances › N/A - No Subsystem › Maintenance of Life Saving Appliances
Issued 19 December 2025
Resolved
PFD's to be properly marked per requirement.
46 CFR 180.25-15(a)OLD T
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 20 January 2026
Resolution: Owner submitted picture of properly marked PFD locations onboard.
11 - Life Saving Appliances › N/A - No Subsystem › Maintenance of Life Saving Appliances
Issued 19 December 2025
Resolved
At each initial and subsequent inspection for certification the marine inspector shall inspect all lifesaving equipment to determine serviceability. Serviceability could not be fully verified on the vessel's life floats during the inspection. Ensure appliance are made fully available for inspection.
46 CFR 176.25-22 (a) OLD T
46 CFR 176.25-22 (a) OLD T
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 6 March 2026
Resolution: Completed satisfactory float test of x2 22-person and x1 25-person life float.
01 - Certificates & Documentation › 011 - Ships Certificates › Other (certificates)
Issued 19 December 2025
Resolved
Vessel name to be added to the bow of the vessel.
46 CFR 67.123
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 20 January 2026
Resolution: Owner submitted pictures attesting to the vessel name being added to the bow and stern.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Windows, sidescuttles and deadlights
Issued 19 December 2025
Resolved
Vessel has a cracked window pane in the pilot house. Repair to the satisfaction of the attending MI.
46 CFR 177.10-1 OLD T
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 20 January 2026
Resolution: Owner submitted picture of new bridge window installed.
10 - Safety of Navigation › N/A - No Subsystem › Other (navigation)
Issued 19 December 2025
Resolved
All electrical installations shall be to the satisfaction of the [name withheld] gear has junction box that requires renewal and an extinguished light.
46 CFR 183.01-15(a) OLD T
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 6 March 2026
Resolution: Verified installation of new junction box and light in lazarette space.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Auxiliary engine
Issued 19 December 2025
Resolved
Auxiliary machinery shall be suitable in type and design for the purpose intended. Water pump on generator found leaking. Vessel must complete repairs within 30 days.
46 CFR 182.10-1 (a) OLD T
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 6 March 2026
Resolution: Verified installation of new waterpump on generator and completed operational test.
01 - Certificates & Documentation › 011 - Ships Certificates › Certificate of Inspection (COI)
Issued 7 February 2025
Resolved
A vessel that is exposed to salt water more than three months in any 12 month period since the last examination must undergo a drydock examination and an internal structural at
least once every two years. Conduct a drydock and internal structural exam prior to carriage of passengers.
Action required: 701 - Prior to carriage of passengers/cargo
Due 7 February 2025
Resolved 14 April 2025
Resolution: Vessel completed credit DDX/ISE on 14APR2025. Cleared.
09 - Working and Living Conditions › 092 - Working Conditions › Winches & capstans
Issued 8 June 2023
Resolved
Two flexible non-metallic hoses for the winch/capstan penetrate the watertight main deck. Each penetration must be accomplished using an acceptable metallic through deck fitting that is welded or otherwise attached to the deck by an accepted method; and one metallic shutoff valve must be installed if operable from above the bulkhead deck.
Condition: Placed in Improper Service
Action required: 50 - Rectify deficiencies w/in 30 days
Due 8 July 2023
Resolved 18 June 2024
Resolution: Special Consideration granted, OCMI Letter uploaded. Special Note Added.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Covers (hatchway-, portable-, tarpaulins, etc.)
Issued 6 May 2021
Resolved
Area around access hatch in crew space found rotted. Submit repair proposal to the satisfaction of CGMI.
Vessel rep. is waiting for new hatch before commencing repair.
Condition: Damaged By Earlier Event
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 4 June 2021
Resolution: See Activity Number 7208572
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 25 June 2020
Resolved
Replace wing nuts on batterys with approved fasteners.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 25 July 2020
Resolved 29 June 2020
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 25 June 2020
Resolved
Electrical panel in pilothouse for 12 V DC system cover is not fastened on properly. Properly attached panel cover.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 25 July 2020
Resolved 29 June 2020
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 25 June 2020
Resolved
Air gap on E/R vents is excessive, seal E/R vents within acceptable air gap.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 25 July 2020
Resolved 29 June 2020
10 - Safety of Navigation › N/A - No Subsystem › Magnetic compass
Issued 28 June 2019
Resolved
Magnetic compass light was inop. Repair light.
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Resolved 28 June 2019
10 - Safety of Navigation › N/A - No Subsystem › Nautical publications
Issued 28 June 2019
Resolved
Coast Pilot [name withheld], and Charts were out of date and not updated.
Action required: 10 - Deficiency Rectified
Resolved 28 June 2019
11 - Life Saving Appliances › N/A - No Subsystem › Rigid liferafts
Issued 28 June 2019
Resolved
Vessel missing one life float as indicated on COI. Vessel has three 22 man life floats on board and requires 4. Total persons onboard reduced to 66 of which 60 may be passengers for Oceans route warm or cold water and limited Coastwise route in cold water.
Condition: Improper Installation
Action required: 705 - Other - as specified
Resolved 30 June 2020
Fire Fighting › Fire Pumps › Pressure
Issued 8 May 2018
Resolved
Renew gauge on PTO pump
Condition: Placed in Improper Service
Action required: 705 - Other - as specified
Due 15 May 2018
Resolved 15 May 2018
Resolution: Renewed gauge on PTO pump
Electrical › Electrical Distribution System (service) › Junction Box
Issued 8 May 2018
Resolved
Remount electrical junction box over STBD engine.
Condition: Placed in Improper Service
Action required: 705 - Other - as specified
Due 15 May 2018
Resolved 9 May 2018
Resolution: Remounted electrical J-box
Electrical › Lighting (service) › Lighting Fixture
Issued 8 May 2018
Resolved
Install glass globe on lighting fixture in tank room.
Condition: Placed in Improper Service
Action required: 705 - Other - as specified
Due 15 May 2018
Resolved 9 May 2018
Resolution: replaced globe on lighting fixture.
Communications › Radio Communications › EPIRB
Issued 8 May 2018
Resolved
Remount EPIRB in float free location.
Condition: Placed in Improper Service
Action required: 701 - Prior to carriage of passengers/cargo
Due 8 May 2018
Resolved 9 May 2018
Resolution: Epirb has been remounted in float free location.
Construction/Loadline › Structures › Deck Plating
Issued 18 May 2017
Resolved
Make repairs to rotten deck long and plywood area in way of deck scuttle.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 18 June 2017
Resolved 19 July 2017
Resolution: Made repairs to rotten rotted areas.
Construction/Loadline › Structures › Scuttle
Issued 18 May 2017
Resolved
Reinstall safety chains on scuttles for fore peak and laz.
Condition: Placed in Improper Service
Action required: 705 - Other - as specified
Due 18 June 2017
Resolved 26 May 2017
Resolution: Reinstalled safety chains on scuttles for fore peak and laz.
Engineering › Diesel Engine (propulsion-reduction gear) › Piping (exhaust)
Issued 18 May 2017
Resolved
Install new exhaust hose clamp on starboard aft section.
Condition: Placed in Improper Service
Action required: 705 - Other - as specified
Due 18 June 2017
Resolved 26 May 2017
Resolution: Installed new exhaust hose clamp on starboard aft section.
Engineering › Bilge Water Management System › Strainer
Issued 4 April 2017
Resolved
Install adequate sized strainer basket on engine room bilge suction.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 18 April 2017
Resolved 20 April 2017
Resolution: Installed adequate sized strainer basket on engine room bilge suction.
Lifesaving › Lifejacket/PFD (General) › Storage
Issued 4 April 2017
Resolved
Properly mark storage containers for lifejackets.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 18 April 2017
Resolved 20 April 2017
Resolution: Properly marked storage containers for lifejackets.
Fire Fighting › Fire Pumps › Pressure
Issued 4 April 2017
Resolved
Install new pressure gauge on primary fire pump.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 4 April 2017
Resolved 4 April 2017
Resolution: Installed new working pressure gauge.
Operations/Management › Drills/Instruction › Not Conducted
Issued 4 April 2017
Resolved
Conduct drills and underway sea trials.
Condition: Placed in Improper Service
Action required: 705 - Other - as specified
Due 18 April 2017
Resolved 20 April 2017
Resolution: Conducted drills and underway sea trials.
Electrical › Lighting (service) › Switch
Issued 25 August 2016
Resolved
Prior to energizing aft flood light circuit make permanent repairs to the satisfaction of the attending marine inspector.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 25 September 2016
Resolved 4 April 2017
Resolution: Lighting circuit has been permanently removed.
Construction/Loadline › Hull › Transverse Frame
Issued 17 June 2016
Resolved
Prior to next dry dock availability provide detailed written proposal to repair areas of decayed wood in forepeak.
Condition: Improper/Lack of Maintenance
Due 31 December 2016
Resolved 4 April 2017
Resolution: Observed proper repairs made to areas of decayed wood in forepeak.
Engineering › Shafting/Propeller Arrangements › Propeller (fixed pitch)
Issued 2 June 2016
Resolved
Conduct damage survey after line/fish net removed from props and rudder, conduct sea trials to the satisfaction of the attending USCG Marine Inspector.
Condition: Placed in Improper Service
Action required: 701 - Prior to carriage of passengers/cargo
Due 2 June 2016
Resolved 3 June 2016