MAURY USCG vessel records Sign in
← All vessels

MISS MONTAUK II

MISS MONTAUK II is a 1983 passenger vessel (inspected). The Coast Guard has recorded 71 inspections since 1985, most recently in April 2026, along with 77 deficiencies and 1 casualty investigation in 2020.

Records from 1985 to 2026. Most recent: inspection, 27 April 2026.

Built
1983
Last inspected
27 April 2026
Documentation
Valid · documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

WDA4813
Flag
UNITED STATES
366813390
Maury page id
psix-54996

Inspections, by type

…with no type recorded7
Years with a record 38 calendar years (1985–2026)
The 71 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 1977.

Documentation record

Registered dimensions (L × B × D)73.0 ft × 21.0 ft × 6.0 ft
Registered tonnagegross 67 / net 54
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
Builderbuilder not recorded · STUART, FL, UNITED STATES · built 1983
Hull materialWood
PropulsionDiesel Reduction
Hull shapeNot recorded
Hull configurationNot recorded
Hailing portMONTAUK, NY
Trade endorsementsCoastwise, unrestricted, Fishery
DocumentationValid · issued 13 December 2025 · expires 30 November 2026
Service, as the file records itPassenger (Inspected)
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it67 - Regulatory (Subpart C or D), Gross Ton
54 - Regulatory (Subpart C or D), Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 September 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.

Radio station licence

WDN5315MMSI 366813390 · active · compulsorily equipped · granted 14 December 2022, expires 14 December 2032
WDA4813MMSI 366813390 · cancelled · voluntarily equipped · granted 27 April 2021, cancelled 12 December 2022
WBI4416MMSI not assigned · expired · compulsorily equipped · granted 29 May 1998, cancelled 2 August 2008 · licensed under a name not among this hull’s recorded names (not shown)
FCC Universal Licensing System ship-station file of 6 September 2026, matched to this hull on its US Official Number. Status and dates are the file’s own. The licensee is not read from the file and is not shown. A lapsed licence’s MMSI is still the number the vessel transmitted under while it was valid.

Inspection history · 71

27 April 2026 Deficiency Check · Annual Inspection
Physical examination · Marine Safety Unit Coram · USCG Northeast District (CGD-NE) · Activity 8357467
21 October 2025 Drydock Exam · Internal Structural Exam
Physical examination · Marine Safety Unit Coram · USCG Northeast District (CGD-NE) · Activity 8256205
4 June 2025 Type not recorded
No type recorded · USCGC RAZORBILL (WPB 87332) · USCG Heartland District (CGD-H) · Activity 8152386
29 April 2025 Deficiency Check · Administrative Inspection · Annual Inspection
Physical examination · Marine Safety Unit Coram · USCG Northeast District (CGD-NE) · Activity 8121901
29 April 2024 Administrative Inspection · Annual Inspection
Physical examination · Marine Safety Unit Coram · USCG Northeast District (CGD-NE) · Activity 7903095
18 October 2023 Administrative Inspection · Internal Structural Exam · Drydock Exam
Physical examination · Marine Safety Unit Coram · USCG Northeast District (CGD-NE) · Activity 7809306
25 April 2023 Annual Inspection · Administrative Inspection
Physical examination · Marine Safety Unit Coram · USCG Northeast District (CGD-NE) · Activity 7677191
10 November 2022 Administrative Inspection
Administrative · Marine Safety Unit Coram · USCG Northeast District (CGD-NE) · Activity 7592637
26 April 2022 COI Inspection · DAPI Audit
Physical examination · Marine Safety Unit Coram · USCG Northeast District (CGD-NE) · Activity 7397525
13 October 2021 Drydock Exam · Internal Structural Exam
Physical examination · Marine Safety Unit Coram · USCG Northeast District (CGD-NE) · Activity 7326469
26 April 2021 Annual Inspection · Deficiency Check · DAPI Audit
Physical examination · Marine Safety Unit Coram · USCG Northeast District (CGD-NE) · Activity 7213559
5 June 2020 Deficiency Check · Annual Inspection
Physical examination · Marine Safety Unit Coram · USCG Northeast District (CGD-NE) · Activity 6900228
30 May 2020 Type not recorded
No type recorded · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 7080874
8 October 2019 Internal Structural Exam · Drydock Exam
Physical examination · Marine Safety Unit Coram · USCG Northeast District (CGD-NE) · Activity 6820922
30 April 2019 Annual Inspection
Physical examination · Marine Safety Unit Coram · USCG Northeast District (CGD-NE) · Activity 6653494
17 September 2018 Administrative Inspection
Administrative · Navigation Center · Activity 6542526
17 April 2018 Annual Inspection
Physical examination · Marine Safety Unit Coram · USCG Northeast District (CGD-NE) · Activity 6362033
24 January 2018 Administrative Inspection
Administrative · Marine Safety Unit Coram · USCG Northeast District (CGD-NE) · Activity 6343094
10 October 2017 Drydock Exam
Physical examination · Marine Safety Unit Coram · USCG Northeast District (CGD-NE) · Activity 6281991
15 March 2017 Deficiency Check · Administrative Inspection · COI Inspection
Physical examination · Marine Safety Unit Coram · USCG Northeast District (CGD-NE) · Activity 6100887
9 December 2015 COI Inspection
Physical examination · Marine Safety Unit Coram · USCG Northeast District (CGD-NE) · Activity 5778100
12 November 2015 Drydock Exam · Internal Structural Exam
Physical examination · Marine Safety Unit Portsmouth · USCG Northeast District (CGD-NE) · Activity 5762147
12 May 2014 DAPI Audit · Annual Inspection
Physical examination · Marine Safety Unit Portsmouth · USCG Northeast District (CGD-NE) · Activity 4856197
12 December 2011 Administrative Inspection
Administrative · Marine Safety Unit Portsmouth · USCG Northeast District (CGD-NE) · Activity 4206702
2 September 2010 Deficiency Check · Annual Inspection
Physical examination · Marine Safety Unit Portsmouth · USCG Northeast District (CGD-NE) · Activity 3840556
10 June 2008 Annual Inspection
Physical examination · Marine Safety Unit Portsmouth · USCG Northeast District (CGD-NE) · Activity 3232847
7 April 2008 Hull Examination
Physical examination · Marine Safety Unit Portsmouth · USCG Northeast District (CGD-NE) · Activity 3188128
5 June 2007 Annual Inspection
Physical examination · Marine Safety Unit Portsmouth · USCG Northeast District (CGD-NE) · Activity 2953117
30 May 2006 COI Inspection
Physical examination · Marine Safety Unit Portsmouth · USCG Northeast District (CGD-NE) · Activity 2666957
15 March 2006 Hull Examination
Physical examination · Marine Safety Unit Portsmouth · USCG Northeast District (CGD-NE) · Activity 2603629
21 June 2005 Annual Inspection
Physical examination · MSFO Portsmouth · USCG Northeast District (CGD-NE) · Activity 2435876
24 June 2004 Annual Inspection
Physical examination · MSFO Portsmouth · USCG Northeast District (CGD-NE) · Activity 2125144
13 April 2004 Hull Examination
Physical examination · MSFO Portsmouth · USCG Northeast District (CGD-NE) · Activity 2043965
5 June 2003 Re-Inspection
Physical examination · MSFO Portsmouth · USCG Northeast District (CGD-NE) · Activity 1810495
26 March 2003 Administrative Inspection
Administrative · MSFO Portsmouth · USCG Northeast District (CGD-NE) · Activity 1763382
18 March 2002 Re-Inspection · Hull Examination · Internal Structural Exam
Physical examination · MSFO Portsmouth · USCG Northeast District (CGD-NE) · Activity 1494693
12 June 2001 COI Inspection
Physical examination · MSO PORTLAND MAINE · USCG Northeast District (CGD-NE) · Activity 1379462
25 April 2001 Administrative
Administrative · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 1062001
19 April 2001 Administrative
Administrative · MSO PORTLAND MAINE · USCG Northeast District (CGD-NE) · Activity 1061781
25 April 2000 Re-Inspection
Physical examination · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 1379044
23 March 2000 Hull Examination
Physical examination · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 1449299
22 April 1999 COI Inspection
Physical examination · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 1126910
10 November 1998 Type not recorded
No type recorded · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 804945
11 May 1998 Re-Inspection
Physical examination · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 790500
2 April 1998 Hull Examination
Physical examination · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 1123258
22 May 1997 Re-Inspection
Physical examination · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 778813
1 May 1996 COI Inspection
Physical examination · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 1083281
11 April 1996 Hull Examination
Physical examination · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 1079883
4 May 1995 COI Inspection · Deficiency Check
Physical examination · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 1234873
17 May 1994 Administrative
Administrative · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 859752
9 May 1994 COI Inspection
Physical examination · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 1169086
26 April 1994 Hull Examination
Physical examination · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 858096
20 April 1993 COI Inspection
Physical examination · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 1137569
11 June 1992 Type not recorded
No type recorded · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 1270176
21 April 1992 COI Inspection
Physical examination · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 1268831
19 March 1992 Hull Examination
Physical examination · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 1318971
22 March 1991 COI Inspection
Physical examination · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 1305097
26 February 1991 Administrative
Administrative · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 1230869
8 February 1991 Hull Examination
Physical examination · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 905425
19 October 1990 Type not recorded
No type recorded · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 902544
30 March 1990 COI Inspection
Physical examination · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 932995
9 March 1990 Hull Examination
Physical examination · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 1214420
30 March 1989 COI Inspection
Physical examination · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 1350719
24 February 1989 Hull Examination
Physical examination · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 1196143
28 March 1988 COI Inspection
Physical examination · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 991034
10 March 1988 Hull Examination
Physical examination · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 1337680
30 March 1987 COI Inspection
Physical examination · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 1019493
8 September 1986 Credit Drydock
Administrative · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 1332268
27 March 1986 COI Inspection
Physical examination · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 997527
9 April 1985 Type not recorded
No type recorded · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 1288420
8 March 1985 Type not recorded
No type recorded · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 1286949

Deficiency record · 77

05 - Radio Communications › N/A - No Subsystem › Main installation
Issued 27 April 2026 Resolved
Provide FCC Bridge to Bridge cert.
Condition: Placed in Improper Service
Action required: 50 - Rectify deficiencies w/in 30 days
Due 27 May 2026
Resolved 4 May 2026
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 27 April 2026 Resolved
Provide spanner wrenches at fire stations.
Condition: Placed in Improper Service
Action required: 701 - Prior to carriage of passengers/cargo
Due 27 April 2026
Resolved 4 May 2026
08 - Alarms › N/A - No Subsystem › Other (alarms)
Issued 29 April 2025 Resolved
The fuse for the bilge alarms on the bridge was not consistently working. Issued requirement to replace fuse.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 27 May 2025
Resolved 17 June 2025
05 - Radio Communications › N/A - No Subsystem › VHF EPIRB
Issued 29 April 2025 Resolved
Conduct monthly EPIRB checks and log them.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 27 May 2025
Resolved 17 June 2025
09 - Working and Living Conditions › 092 - Working Conditions › Gangway, accommodation-ladder
Issued 29 April 2025 Resolved
Label upper deck max pax at the forward ladder.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 7 May 2025
Resolved 17 June 2025
05 - Radio Communications › N/A - No Subsystem › Other (radio communication)
Issued 29 April 2025 Resolved
VHF radio did not have lat/long hooked up for DSC.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 28 May 2025
Resolved 17 June 2025
05 - Radio Communications › N/A - No Subsystem › Satellite EPIRB 406MHz/1.6GHz
Issued 26 April 2022 Resolved
The EPIRB battery was expired. Issued a CG-835 to limit the vessel to remain within 03NM until the vessel had an EPIRB with a non expired battery.
Condition: Invalid
Action required: 705 - Other - as specified
Due 26 May 2022
Resolved 29 April 2022
Resolution: Received proof of EPIRB replacement.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 26 April 2021 Resolved
One of the vessels ring buoy lifelines had separated due to sun/sea exposure. Issued a requirement to provide new life ring.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 26 May 2021
Resolved 30 April 2021
Resolution: Replaced life ring.
11 - Life Saving Appliances › N/A - No Subsystem › Rigid liferafts
Issued 26 April 2021 Resolved
Vessel had gouges from seagulls in several life floats. Issued requirement to repair life floats.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 26 April 2021
Resolved 26 May 2021
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 5 June 2020 Resolved
Prior to operating on Coastwise or Oceans route install lights on PFD's currently only 55 PFD's onboard have lights installed.
Condition: Placed in Improper Service
Action required: 705 - Other - as specified
Due 5 June 2020
Resolved 11 October 2020
05 - Radio Communications › N/A - No Subsystem › VHF radio installation
Issued 5 June 2020 Resolved
Program DSC capable radio to display MMSI # and location information.
Condition: Placed in Improper Service
Action required: 50 - Rectify deficiencies w/in 30 days
Due 5 July 2020
Resolved 19 June 2020
04 - Emergency Systems › N/A - No Subsystem › Water level indicator
Issued 30 April 2019 Resolved
High water alarms not installed in each space of wood hull vessel. alarms required in the 2 forward compartments.
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 30 May 2019
Resolved 30 April 2019
Resolution: O/O removed from service and decreased maxx persons on cold water routes.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 30 April 2019 Resolved
Labling/ new life ring installedon the vessel and not labled yet. vessel representative labled the life ring prior to us departing.
Condition: Improper Installation
Action required: 10 - Deficiency Rectified
Due 30 April 2019
Resolved 30 April 2019
Resolution: Corrected on the spot.
11 - Life Saving Appliances › N/A - No Subsystem › Maintenance of Life Saving Appliances
Issued 30 April 2019 Resolved
Grab lines for life floats were found wasted and detatched from the life float. Repair from an approved facility or replace the device.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 30 May 2019
Resolved 6 June 2019
Resolution: Life float replaced with new float and provisions transfered to the new float. Deficiency cleared.
11 - Life Saving Appliances › N/A - No Subsystem › Maintenance of Life Saving Appliances
Issued 30 April 2019 Resolved
Life float found in unservicable condition due to prolonged exposure to elements. O/O destroyed the device before the qualified marine inspector and reduced carriage to 88 max persons on cold water route.
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Due 30 April 2019
Resolved 30 April 2019
Resolution: O/O removed life float from service and took passenger count reduction
10 - Safety of Navigation › N/A - No Subsystem › Automatic Identification System (AIS)
Issued 17 September 2018 Resolved
Vsl is not broadcasting a Call Sign
Condition: Invalid
Action required: 705 - Other - as specified
Due 18 November 2018
Resolved 27 June 2019
Resolution: Verified CG NAVCEN VIVS, no AIS deficiencies pending per website.
Engineering › Sea-water System (primary cooling) › Piping
Issued 10 May 2017 Resolved
Repair center engine wet exhaust piping (cracked/leaking)
Action required: 705 - Other - as specified
Due 24 May 2017
Resolved 30 May 2017
Resolution: repaired
Deck/Cargo › Holds/Tanks › Scuttle
Issued 15 March 2017 Resolved
Open (frozen shut)scuttles for LAZ and Collision Compartments for inspection. Both are frozen shut due to weather.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 15 April 2017
Resolved 10 May 2017
Resolution: completed
Engineering › Bilge Water Management System › Not Operational
Issued 15 March 2017 Resolved
Prove proper operation of bilge suction, and test high water alarms in engine room LAZ and Collision compartments to prove proper operation.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 15 April 2017
Resolved 10 May 2017
Resolution: completed satisfactory
Fire Fighting › Fire Pumps › Pressure
Issued 15 March 2017 Resolved
Prove proper operation of fire pump.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 15 April 2017
Resolved 10 May 2017
Resolution: tested sat
Operations/Management › Drills/Instruction › Man Overboard Recovery
Issued 15 March 2017 Resolved
Conduct MOB and Fire Drills to the satisfaction of a CG Marine Inspector.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 15 April 2017
Resolved 10 May 2017
Resolution: conducted sat
Engineering › Steering Gear System › Rudder
Issued 15 March 2017 Resolved
Prove proper operation of the steering system.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 15 April 2017
Resolved 10 May 2017
Resolution: tested sat
Operations/Management › Drug and Alcohol Testing › Recordkeeping
Issued 15 March 2017 Resolved
Provide MIS reporrt for DAPI for 2016.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 15 April 2017
Resolved 10 May 2017
Resolution: provided copy
Communications › Radio Communications › VHF Radiotelephone
Issued 15 March 2017 Resolved
Provide/post FCC safety cert and FCC Bridge to Bridge Cert.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 15 April 2017
Resolved 31 July 2017
Resolution: FCC safety provided 5/10/2017
Lifesaving › Lifefloat › Markings
Issued 15 March 2017 Resolved
Relable L/F and ring buoys.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 15 April 2017
Resolved 10 May 2017
Resolution: labeled
Fire Fighting › Fire Pumps › Casing
Issued 28 December 2015 Resolved
Fire pump inoperable due to bolt needing replacement.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 28 December 2015
Resolved 6 January 2016
Resolution: Vessel owner purchased a new fire pump to replace the existing damaged one. Fire pump tested and exhibited adequete pressure at discharge side of pump and at the fire station nozzle.
Engineering › Fuel Oil Storage/Transfer System › Piping
Issued 28 December 2015 Resolved
Port and starboard fuel tanks have unapproved piping.
Condition: Design Flaw
Action required: 705 - Other - as specified
Due 4 January 2016
Resolved 6 January 2016
Resolution: Fuel lines have been replaced with correct type.
Stability › Watertight Integrity › Watertight Subdivision Standard
Issued 28 December 2015 Resolved
Forward engine room watertight bulkhead has open wire runs.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 4 January 2016
Resolved 6 January 2016
Resolution: Bulkhead wire runs have been sealed to be watertight.
Electrical › Electric Supply System (service) › Cable
Issued 28 December 2015 Resolved
Dead end wiring in engine room and tank room.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 4 January 2016
Resolved 6 January 2016
Resolution: Dead end wiring has been removed.
Accommodation/Occupational Safety › Occupational Safety › Guards for Exposed Hazards
Issued 28 December 2015 Resolved
Mechanical guards missing on all three main engines.
Condition: Design Flaw
Action required: 705 - Other - as specified
Due 4 January 2016
Resolved 6 January 2016
Resolution: Mechanical guards have been installed on all three engines.
Engineering › Shafting/Propeller Arrangements › Stern Tube
Issued 28 December 2015 Resolved
Port and center shaft packing leaking.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 4 January 2016
Resolved 6 January 2016
Resolution: Shaft packing was tighted and leaking stopped.
Documentation › Markings/Placards › Capacity Marking
Issued 28 December 2015 Resolved
Maximum passengers for upper 02 deck missing.
Action required: 705 - Other - as specified
Due 4 January 2016
Resolved 6 January 2016
Resolution: Maximum upper deck passenger placard was installed.
Deck/Cargo › Mooring/Anchoring › Capstan
Issued 28 December 2015 Resolved
Hydraulic hose wasted on anchor tank in starboard engine room.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 4 January 2016
Resolved 6 January 2016
Resolution: Hydrallic hose was removed and replaced with a new hydrallic hose.
Construction/Loadline › Hull › Side Shell
Issued 27 November 2015 Resolved
Bow pulpit was damaged due to a cleat being ripped out due to excessive current during high tide. Repair damaged bow pulpit area.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 28 December 2015
Resolution: Bow pulpit has been permanantly repaired using wood framing and reinforced with West system epoxy. The cleat was not replaced during the repair as the operator stated that it would not be utilized in current mooring configuration.
Fire Fighting › Ventilation Systems › Duct Hatches
Issued 2 September 2010 Resolved
Provide vent closures for engine room.
Due 16 September 2010
Resolved 20 September 2010
Construction/Loadline › Structures › Superstructure
Issued 2 September 2010 Resolved
Replace boken glass on bridge windows.
Due 16 September 2010
Resolved 20 September 2010
Lifesaving › Lifejacket/PFD (Type I) › Retroreflective Material
Issued 10 June 2008 Resolved
Replace reflective material on two childrens lifejackets.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Resolved 10 June 2008
Lifesaving › Lifejacket/PFD (Type I) › Condition
Issued 10 June 2008 Resolved
Provide ten adult type I lifejackets, passenger count reduced to 131.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Resolved 10 June 2008
Communications › Alarms/Indicators › Bilge Alarm
Issued 5 June 2007 Resolved
Repair/Replace float switch for hi water alarm located in fuel tank compartment.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 12 June 2007
Resolved 7 June 2007
Lifesaving › Lifejacket/PFD (Type I) › Condition
Issued 5 June 2007 Resolved
Renew three adult lifejackets. Passengers reduced to 138.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Resolved 7 June 2007
Electrical › Electrical Distribution System (service) › Conductor
Issued 5 June 2007 Resolved
Provide wire connectors and electrical tape on all hi water alarms and electrical bilge pump connections.
Action required: 705 - Other - as specified
Due 5 July 2007
Resolved 5 June 2007
Documentation › Markings/Placards › Capacity Marking
Issued 5 June 2007 Resolved
Mark upper deck with "36 MAX PASSENGERS"
Condition: Improper/Lack of Maintenance
Due 12 June 2007
Resolved 12 June 2007
Resolution: Plastic Placard Provided.
Engineering › Fuel Oil Service System › Filter
Issued 5 June 2007 Resolved
Provide flame bowl for racor filter supplying port generator.
Condition: Improper/Lack of Maintenance
Due 12 June 2007
Resolved 5 June 2007
Resolution: Provided bowl.
Operations/Management › Pollution › Control of Garbage
Issued 5 June 2007 Resolved
Provide missing waste management plan.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 12 June 2007
Resolved 5 June 2007
Lifesaving › Lifejacket/PFD (Type I) › Condition
Issued 30 May 2006 Resolved
Renew eight adult lifejackets passenger count reduced to one hundred thirty three.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 6 June 2006
Resolved 9 June 2006
Lifesaving › Lifefloat › Painter
Issued 30 May 2006 Resolved
Provide correct line attaching rafts to painter line.
Action required: 705 - Other - as specified
Due 6 June 2006
Resolved 9 June 2006
Lifesaving › Lifejacket/PFD (Type I) › Condition
Issued 24 June 2004 Resolved
Provide one adult lifejacket.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 24 June 2004
Resolved 24 June 2004
Resolution: Provided
Lifesaving › Lifebuoys › Serviceable
Issued 24 June 2004 Resolved
Renew grab lines on lifebuoy. Provide clip for waterlight.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 26 June 2004
Resolved 30 June 2004
Engineering
Issued 12 June 2001 Resolved
MAKE PERMANENT REPAIRS TO THE STBD FUEL TANK VALVE TO PREVENT LEAKING.
Condition: Unknown
Due 12 June 2001
Resolved 13 June 2001
Lifesaving
Issued 12 June 2001 Resolved
REGISTER EPIRB
Condition: Unknown
Due 12 June 2001
Resolved 13 June 2001
Navigation
Issued 25 April 2000 Resolved
INSTALL PROPER TYPE OF NAVIGATIONAL LIGHT BLUB FOR STERN LIGHT.
Condition: Unknown
Due 25 April 2000
Resolved 25 April 2000
Fire Fighting
Issued 25 April 2000 Resolved
PROVIDE SPANNER FOR STARBOARD FIRE STATION.
Condition: Unknown
Due 25 April 2000
Resolved 25 April 2000
Engineering
Issued 25 April 2000 Resolved
RENEW PORT MAIN ENGINE TURBO'S AND OIL AND DRAIN LINES.
Condition: Unknown
Due 25 April 2000
Resolved 25 April 2000
Construction/Loadline
Issued 25 April 2000 Resolved
FREE UP CHECK VALVE TO FORWARD PEAK TANK BILGE SUCTION.
Condition: Unknown
Due 25 April 2000
Resolved 25 April 2000
Fire Fighting
Issued 25 April 2000 Resolved
SERVICE VESSEL'S FIXED CO2 SYSTEM AND PROVIDE MSO BOSTON A COPY OF THE SERVICING REPORT.
Condition: Unknown
Due 25 April 2000
Resolved 25 April 2000
Documentation
Issued 22 April 1999 Resolved
PROVIDE PROOF OF CURRENT RADIOTELEPHONY CERTIFICATE.
Condition: Unknown
Due 12 May 1999
Resolved 12 May 1999
Lifesaving
Issued 22 April 1999 Resolved
PROVIDE VESSEL'S NAME AND RETROREFLECTIVE TAPE ON 2 LIFE RINGS.
Condition: Unknown
Due 12 May 1999
Resolved 12 May 1999
Lifesaving
Issued 22 April 1999 Resolved
REPAIR CRACKS ON THE SURFACE OF LIFE FLOAT LOCATED ON THE PILOT HOUSE, PORTSIDE.
Condition: Unknown
Due 12 May 1999
Resolved 12 May 1999
Fire Fighting
Issued 22 April 1999 Resolved
MOUNT OPERATING INSTRUCTIONS FOR FIXED GAS FIRE FIGHTING EXTINGUISHING SYSTEM.
Condition: Unknown
Due 12 May 1999
Resolved 12 May 1999
Construction/Loadline
Issued 22 April 1999 Resolved
PROPERLY SEAL SMALL HOLES IN FORWARD ENGINE ROOM BULKHEAD.
Condition: Unknown
Due 12 May 1999
Resolved 12 May 1999
Navigation
Issued 2 April 1998 Resolved
RENEW AS ORIGINAL THE TIE ROD CONNECTING BOTH RUDDER POSTS IN THE LAZARETTE.
Condition: Unknown
Due 2 April 1998
Resolved 2 April 1998
Construction/Loadline
Issued 2 April 1998 Resolved
MAKE WATERTIGHT ALL THRU BULKHEAD PENETRATIONS IN ALL FOUR WATERTIGHT BULKHEADS IN WAY OF CABLE/PIPE/EXHAUST RUNS.
Condition: Unknown
Due 2 April 1998
Resolved 2 April 1998
Fire Fighting
Issued 22 May 1997 Resolved
STENCIL/APPLY VESSEL NAME ON FIRE AXE.
Condition: Unknown
Due 29 May 1997
Resolved 11 July 1997
Lifesaving
Issued 22 May 1997 Resolved
REPAIR MINOR SURFACE CRACKS IN LIFE FLOATS.
Condition: Unknown
Due 29 May 1997
Resolved 11 July 1997
Lifesaving
Issued 1 May 1996 Resolved
RENEWED RING BUOY RETRO REFLECTIVE TAPE THIS EXAM.
Condition: Unknown
Due 1 May 1996
Resolved 6 May 1996
Fire Fighting
Issued 1 May 1996 Resolved
REPLACED ENGINE ROOM B-I SIZE PORTABLE EXTINGUISHERS WITH REQUIRED SIZE _x001C_ B-II THIS EXAM.
Condition: Unknown
Due 1 May 1996
Resolved 6 May 1996
Construction/Loadline
Issued 1 May 1996 Resolved
REPLACED LANYARDS TO FOREPEAK AND STEERING GEAR COMPT. WATERTIGHT SCUTTLES THIS EXAM.
Condition: Unknown
Due 1 May 1996
Resolved 6 May 1996
Engineering
Issued 1 May 1996 Resolved
REPLACED FUEL TANK VENT LINES PREVIOUSLY REMOVED FOR WINTER STORAGE.
Condition: Unknown
Due 1 May 1996
Resolved 6 May 1996
Construction/Loadline
Issued 1 May 1996 Resolved
BILGE ALARMS FOUND INOPERATIVE, REPAIRED THIS EXAM.
Condition: Unknown
Due 1 May 1996
Resolved 6 May 1996
Electrical
Issued 1 May 1996 Resolved
PROPERLY INSTALLED MISC. LOOSE WIRING UNDER BRIDGE CONTROL PANEL.
Condition: Unknown
Due 1 May 1996
Resolved 6 May 1996
Deck/Cargo
Issued 4 May 1995 Resolved
REPLACE RELIEF VALVE TO AIR RECEIVER IN ENGINE ROMM, NO LATER THAN 15 MAY, 1995.
Condition: Unknown
Due 15 May 1995
Resolved 19 May 1995
Lifesaving
Issued 4 May 1995 Resolved
RENEW IN KIND, ROTTED LINE CONNECTING LIFE FLOATS ON FLYING BRIDGE, PRIOR TO OPERATION AND NO LATER THAN 04 MAY 95.
Condition: Unknown
Due 4 May 1995
Resolved 17 May 1995
Fire Fighting
Issued 4 May 1995 Resolved
PROPERLY MOUNT FIRE AXE AND LABEL AXE WITH VESSEL'S NAME.
Condition: Unknown
Due 4 May 1995
Resolved 17 May 1995
Lifesaving
Issued 4 May 1995 Resolved
PLACE TWO ADDITIONAL HAND SMOKE DISTRESS SIGNALS ON BOARD.
Condition: Unknown
Due 4 May 1995
Resolved 17 May 1995
Lifesaving
Issued 4 May 1995 Resolved
REMOVE FROM VESSEL, OR RENEW HYDROSTATIC RELEASE TO EPIRB NO LATER THAN 15 MAY, 1995. IF REMOVE FROM VESSEL, SUBMIT REQUEST IN WRITING TO MSO BOSTON OFFICE.
Condition: Unknown
Due 15 May 1995
Resolved 19 May 1995
Lifesaving
Issued 4 May 1995 Resolved
RENEW TORN RING BUOY WITH APPROVED RING BUOY NO LATER THAN 04 MAY 95.
Condition: Unknown
Due 4 May 1995
Resolved 17 May 1995
Engineering
Issued 20 April 1993 Resolved
REPAIR/REPLACE STARBOARD MAIN ENGINE REMOTE EMERGENCY STOP CABLE AND PROVE OPERATION TO ATTENDING COAST GUARD MARINE INSPECTOR PRIOR TO BUT NOT LATER THAN 20 MAY 1993.
Condition: Unknown
Due 20 April 1993
Resolved 20 April 1993

Casualty record · 1

30 May 2020Routine · role: Involved in a Marine Casualty · 1 injured · activity 7080874
Each line is an incident investigation the Coast Guard recorded with this hull among the vessels involved, with the date and the classification the Coast Guard gave it, and the bridge, lock or dam the investigation names where it names one. Involvement is not fault. The investigation narrative is not published. Source: IIR, through 2026.

Ownership record