Records from 2016 to 2026. Most recent: inspection, 15 June 2026.
Inspection history · 19
15 June 2026
Annual Inspection
Physical examination · Marine Safety Unit Cape Cod · USCG Northeast District (CGD-NE) · Activity 8405228
15 April 2026
Drydock Exam · Internal Structural Exam
Physical examination · Marine Safety Unit Cape Cod · USCG Northeast District (CGD-NE) · Activity 8350056
5 May 2025
Annual Inspection
Physical examination · Marine Safety Unit Cape Cod · USCG Northeast District (CGD-NE) · Activity 8128606
30 April 2024
COI Inspection
Physical examination · Marine Safety Unit Cape Cod · USCG Northeast District (CGD-NE) · Activity 7901323
27 March 2024
Internal Structural Exam · Drydock Exam
Physical examination · Marine Safety Unit Cape Cod · USCG Northeast District (CGD-NE) · Activity 7879015
15 August 2023
Annual Inspection
Physical examination · Marine Safety Unit Cape Cod · USCG Northeast District (CGD-NE) · Activity 7765774
27 April 2022
Annual Inspection
Physical examination · Marine Safety Unit Cape Cod · USCG Northeast District (CGD-NE) · Activity 7436066
8 March 2022
Internal Structural Exam · Deficiency Check · Drydock Exam · Hull Examination
Physical examination · Marine Safety Unit Cape Cod · USCG Northeast District (CGD-NE) · Activity 7414095
15 October 2021
Annual Inspection
Physical examination · Marine Safety Unit Cape Cod · USCG Northeast District (CGD-NE) · Activity 7333536
6 May 2020
DAPI Audit · Internal Structural Exam · COI Inspection · Drydock Exam
Physical examination · Marine Safety Unit Cape Cod · USCG Northeast District (CGD-NE) · Activity 7043313
24 February 2020
Construction Oversight
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 6914283
14 May 2019
Annual Inspection · DAPI Audit
Physical examination · Marine Safety Unit Cape Cod · USCG Northeast District (CGD-NE) · Activity 6681096
25 October 2018
Deficiency Check
Physical examination · Marine Safety Unit Cape Cod · USCG Northeast District (CGD-NE) · Activity 6567973
14 September 2018
Annual Inspection · DAPI Audit · Administrative Inspection
Physical examination · Marine Safety Unit Cape Cod · USCG Northeast District (CGD-NE) · Activity 6547388
8 March 2018
Hull Examination
Physical examination · Marine Safety Unit Cape Cod · USCG Northeast District (CGD-NE) · Activity 6368385
13 September 2017
DAPI Audit · Annual Inspection
Physical examination · Marine Safety Unit Cape Cod · USCG Northeast District (CGD-NE) · Activity 6265240
2 September 2016
Deficiency Check
Physical examination · Marine Safety Unit Cape Cod · USCG Northeast District (CGD-NE) · Activity 5990570
11 August 2016
Annual Inspection
Physical examination · Marine Safety Unit Cape Cod · USCG Northeast District (CGD-NE) · Activity 5970577
14 April 2016
Hull Examination · Administrative Inspection
Physical examination · Marine Safety Unit Cape Cod · USCG Northeast District (CGD-NE) · Activity 5856443
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 30 April 2024
Resolved
Shutoff valves, installed so as to close against the fuel flow, must be fitted in the fuel supply lines, one at the tank connection and one at the engine end of the fuel line to stop fuel flow when servicing accessories. The shutoff valve at the tank must be manually operable from outside the compartment in which the valve is located, preferably from an accessible position on the weather deck. If the handle to the shutoff valve at the tank is located inside the machinery space, it must be located so that the operator does not have to reach more than 300 millimeters (12 inches) into the machinery space and the valve handle must be shielded from flames by the same material the hull is constructed of, or some noncombustible material. Electric solenoid valves must not be used, unless used in addition to the manual valve. Shut off valve was located Approx. 2 1/2' into the compartment. Install a remote pull for the emergency fuel shutoff valve.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 1 May 2024
Resolution: Received a video of newly installed pull for emergency fuel shut off
01 - Certificates & Documentation › 012 - Crew Certificates › Medical certificate
Issued 15 August 2023
Resolved
The Coast Guard will issue a medical certificate to a mariner meeting the medical and physical standards for merchant mariners. Vessel Master could not produce the medical license or documentation had been issued. Provide proof to the satisfaction of the attending Marine Inspector.
46 CFR 10.301
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 15 September 2023
Resolved 15 August 2023
Resolution: Master provided medical cert.
07 - Fire Safety › N/A - No Subsystem › Maintenance of Fire protection systems
Issued 15 October 2021
Resolved
The owner, managing operator or a qualified servicing facility shall conduct the following inspections and tests: for portable fire extinguishers, the inspections, maintenance procedures and hydrostatic pressure tests required by Chapter 4 of NFPA 10. Portable fire extinguishers were last inspected by third party on June 11, 2020.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 8 March 2022
Resolution: Vessel underwent 3rd party servicing for FF equipment.
07 - Fire Safety › N/A - No Subsystem › Maintenance of Fire protection systems
Issued 15 October 2021
Resolved
The owner, managing operator or a qualified servicing facility shall conduct the following inspections and tests: for fixed gas fire extinguishing systems, the inspections and tests required by Table 176.810(b)(2), in addition to 46 CFR 147.60, 147.65, 147.66 and 147.67.
Pre-engineered fire extinguishing equipment was last inspected by third party on June 11, 2020.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 8 March 2022
Resolution: Vessel underwent 3rd party servicing for FF equipment.
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 15 October 2021
Resolved
A vessel's hull must not carry current as a conductor.
Grounding wires were found to be corroded and disconnected from the vessel's rudder plate.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 8 March 2022
Resolution: Grounding wires were found to be appropriately attached.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 15 October 2021
Resolved
A submersible electric bilge pump bilge pump must be listed by an independent laboratory as meeting the requirements in UL 1113. The installed bilge pump does not meet UL 1113.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 8 March 2022
Resolution: Bilge pump was appropriately replaced with a RULE 2000.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 15 October 2021
Resolved
At each initial and subsequent inspection for certification of a vessel, the owner or managing operator shall be prepared to conduct tests and have the vessel ready for inspections of machinery and piping systems. Wet exhaust hose was found to be dry-rotted.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 8 March 2022
Resolution: Wet exhaust hose was replaced by owner/operator.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 15 October 2021
Resolved
Remote fuel shutoff stations must be marked in clearly legible letters at least 1 inch high indicating purpose of the valve and direction of operation. Letters were faded to the point of illegibility.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 8 March 2022
Resolution: Remote fuel shutoff stations were appropriately stenciled.
01 - Certificates & Documentation › 011 - Ships Certificates › Certificate of Inspection (COI)
Issued 15 October 2021
Resolved
A vessel must undergo an annual inspection within the 3 months before or after each anniversary date. Vessel continued to operate beyond its 90-day window.
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Resolved 15 October 2021
Resolution: Deficiency cleared on the spot.
Fire Fighting › Portable CO2 Fire Extinguisher › Mounting Bracket
Issued 13 September 2017
Resolved
Vesel's B-II fire extinguishing bracket is severly wasted. Replace with a new bracket.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 1 May 2018
Resolved 25 October 2018
Resolution: Vessel installed new fire extinguisher bracket.
Lifesaving › Lifebuoys › Self-igniting Lights
Issued 11 August 2016
Resolved
Lifebuoy did not have the proper length of line for the water light. Provide the a new line that is the proper length.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 18 August 2016
Resolved 1 September 2016
Resolution: Verified vessel had the proper length of line on their lifebuoy; all sat.
Lifesaving › Lifejacket/PFD (General) › Storage
Issued 11 August 2016
Resolved
Vessel does not have their child and adult lifejackets stowage properly labeled with amount of each type. Properly label the stowage compartment with the proper amount of each lifejacket.
Condition: Improper/Lack of Maintenance
Due 18 August 2016
Resolved 1 September 2016
Resolution: Verified vessel had properly labeled their lifejacket stowage compartment; all sat.