Records from 2009 to 2025. Most recent: inspection, 11 June 2025.
Inspection history · 16
11 June 2025
Type not recorded
No type recorded · USCGC RAZORBILL (WPB 87332) · USCG Heartland District (CGD-H) · Activity 8157473
8 May 2025
Deficiency Check · Annual Inspection · Administrative Inspection
Physical examination · Marine Safety Unit Coram · USCG Northeast District (CGD-NE) · Activity 8130512
10 December 2024
Drydock Exam · Internal Structural Exam · Administrative Inspection
Physical examination · Marine Safety Unit Coram · USCG Northeast District (CGD-NE) · Activity 8045136
29 April 2024
Administrative Inspection · Annual Inspection
Physical examination · Marine Safety Unit Coram · USCG Northeast District (CGD-NE) · Activity 7903588
2 July 2023
Type not recorded
No type recorded · Marine Safety Unit Coram · USCG Northeast District (CGD-NE) · Activity 7739381
27 April 2023
Annual Inspection · DAPI Audit
Physical examination · Marine Safety Unit Coram · USCG Northeast District (CGD-NE) · Activity 7677567
7 December 2022
Drydock Exam · Internal Structural Exam
Physical examination · Marine Safety Unit Coram · USCG Northeast District (CGD-NE) · Activity 7605865
28 April 2022
DAPI Audit · Deficiency Check · Annual Inspection
Physical examination · Marine Safety Unit Coram · USCG Northeast District (CGD-NE) · Activity 7449963
9 September 2021
Examination of Repairs
Physical examination · Marine Safety Unit Coram · USCG Northeast District (CGD-NE) · Activity 7308388
15 April 2021
COI Inspection
Physical examination · Marine Safety Unit Coram · USCG Northeast District (CGD-NE) · Activity 7163518
30 December 2020
Internal Structural Exam · Drydock Exam · Examination of Repairs
Physical examination · Marine Safety Unit Coram · USCG Northeast District (CGD-NE) · Activity 7117695
11 September 2020
Administrative Inspection
Administrative · Marine Safety Unit Coram · USCG Northeast District (CGD-NE) · Activity 7055894
29 August 2019
In-Service Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 6798183
17 May 2019
COI Inspection
Physical examination · Marine Safety Unit Coram · USCG Northeast District (CGD-NE) · Activity 6667613
17 December 2018
COI Inspection · Administrative Inspection
Physical examination · Detached Duty Office Fort Myers · USCG Southeast District (CGD-SE) · Activity 6616778
26 April 2018
Drydock Exam · Administrative Inspection · Internal Structural Exam
Physical examination · Detached Duty Office Fort Myers · USCG Southeast District (CGD-SE) · Activity 6398519
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 8 May 2025
Resolved
Service 40BC fire extinguisher or provide an additional approved portable fire 40BC extinguisher.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 8 May 2025
Resolved 8 May 2025
Resolution: O/O provided proof of service
05 - Radio Communications › N/A - No Subsystem › VHF EPIRB
Issued 8 May 2025
Resolved
Install a new hydrostatic release for EPIRB.
Condition: Placed in Improper Service
Action required: 10 - Deficiency Rectified
Due 8 May 2025
Resolved 8 May 2025
Resolution: Corrected on the spot.
11 - Life Saving Appliances › N/A - No Subsystem › Distress flares
Issued 8 May 2025
Resolved
Provide 1 additional hand flare.
Condition: Improper Installation
Action required: 10 - Deficiency Rectified
Due 8 May 2025
Resolved 8 May 2025
Resolution: Corrected on the spot
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 8 May 2025
Resolved
Install flame prevention bowls on fuel filters
Condition: Placed in Improper Service
Action required: 16 - Rectify deficiencies w/in 14 days
Due 22 May 2025
Resolved 9 May 2025
Resolution: Bowls installed
09 - Working and Living Conditions › 091 - Living Conditions › Medical Equipment
Issued 28 April 2022
Resolved
Items in first aid kit expired/missing. Issued requirement to replace items.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 28 May 2022
Resolved 7 June 2022
Resolution: Replaced
11 - Life Saving Appliances › N/A - No Subsystem › Distress flares
Issued 28 April 2022
Resolved
Missing six flares. Issued requirement to have 6 red and 6 orange or 12 red.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 28 May 2022
Resolved 7 June 2022
Resolution: Bought new flares
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 15 April 2021
Resolved
Vessel is limited to to NO MORE THAN 102 persons until additional approved lifejackets are provided.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 30 April 2021
Resolved 28 April 2022
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 15 April 2021
Resolved
Label all life jackets with new vessel name.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 30 April 2021
Resolved 13 May 2021
Resolution: O/O Provided proof of completion of requirement.
07 - Fire Safety › N/A - No Subsystem › Fire pumps and its pipes
Issued 15 April 2021
Resolved
Repair or replace fire pump discharge pressure gauge
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 30 April 2021
Resolved 13 May 2021
Resolution: O/O provided proof of eplacement of guage
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 30 December 2020
Resolved
Address steering ram leaks on Port and Starboard rams.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 30 January 2021
Resolved 22 January 2021
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 30 December 2020
Resolved
Double clamp all raw water hoses in Engine room.
Condition: Placed in Improper Service
Action required: 705 - Other - as specified
Due 30 January 2021
Resolved 5 January 2021
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 29 August 2019
Resolved
VSL is required to have DAPI program. VSL does not have a valid DAPI program. 46 CFR 16.201
Action required: 701 - Prior to carriage of passengers/cargo
Due 29 August 2019
Resolved 30 August 2019
Resolution: Recieved email with required documents.
07 - Fire Safety › N/A - No Subsystem › Fire detection and alarm system
Issued 29 August 2019
Resolved
Spaces must be equipped whit a fire detection system and alarm system of an approved type installed IAW 46 CFR part 76. CO2 Alarm panel did not provide audible alarm. CO2 alarm system was not able to produce audible and visual signals while operating in emergency mode for a period of 30 min.
46 CFR 181.405 (a)
Action required: 701 - Prior to carriage of passengers/cargo
Due 29 August 2019
Resolved 30 August 2019
Resolution: Recieved video showing proper operation.
07 - Fire Safety › N/A - No Subsystem › Maintenance of Fire protection systems
Issued 29 August 2019
Resolved
Annual servicing is required on all fire extinguishing systems. VSL fire extinguishing system are due for inspection by 01 SEPT 2019. 46 CFR 176.810 (2)
Action required: 705 - Other - as specified
Due 31 August 2019
Resolved 10 January 2020
Resolution: Documentation providet all SAT
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 17 May 2019
Resolved
An adult life jacket must be provided for each person on board. vessel was certificated to carry 133 passengers where there were only 93 life jackets on board.
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 16 June 2019
Resolved 20 May 2019
Resolution: Adequate number of PFD's provided
01 - Certificates & Documentation › 013 - Documents › Log-books/compulsory entries
Issued 17 May 2019
Resolved
provide logs and records IAW 46 CFR 185 (b). Logs to include paseenger counts, training and maintenance
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 16 June 2019
Resolved 20 May 2019
Resolution: Updated log books provided
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 17 May 2019
Resolved
portable fire fighting equipment had no records of inspections. Service and provide records of inspecection
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 16 June 2019
Resolved 29 May 2019
Resolution: Updated inspection reports provided
08 - Alarms › N/A - No Subsystem › Other (alarms)
Issued 17 May 2019
Resolved
Prove operation of high water alarms in required spaces
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 16 June 2019
Resolved 20 May 2019
Resolution: Hi level alarms tested sat
09 - Working and Living Conditions › 091 - Living Conditions › Electrical devices
Issued 17 May 2019
Resolved
Junction required for overhead lighting in "crew only" space.
Properly install.
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 16 June 2019
Resolved 20 May 2019
Resolution: Properly installed electrical junction box
14 - Pollution Prevention › 141 - MARPOL Annex I › Control of discharge
Issued 17 May 2019
Resolved
Secure overboard bilge discharge plug in tank space which is no longer being used
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 16 June 2019
Resolved 20 May 2019
Resolution: O/O properly installed overboard discharge
14 - Pollution Prevention › 141 - MARPOL Annex I › Oil fuel tank protection
Issued 17 May 2019
Resolved
Properly install fuel sight glass on fuel tank or remove non functional sight glass from service IAW 46 CFR 185.100
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 16 June 2019
Resolved 29 May 2019
Resolution: O/O installed glass site glass with guards
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 17 May 2019
Resolved
Install UL approved breakers for the AC panel panel at the operating station.
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 16 June 2019
Resolved 29 May 2019
Resolution: AC panel was identified to meet UL standards
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 17 May 2019
Resolved
Install UL approved breakers for the DC panel at the operating station
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 16 June 2019
Resolved 22 January 2021
Resolution: DC panel was identified to meet UL standards
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 17 May 2019
Resolved
IAW MSC letter, Date 15 April 2019, provide updated electrical systems drawings to MSC. Ref. (b) & (c)
Condition: Design Flaw
Action required: 50 - Rectify deficiencies w/in 30 days
Due 16 June 2019
Resolved 22 January 2021
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 17 May 2019
Resolved
Per MSC letter 15 April 2019, Install electrical equipment outlined in line 7.
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 16 June 2019
Resolved 22 January 2021
02 - Structural Conditions › N/A - No Subsystem › Hull damage impairing seaworthiness
Issued 17 May 2019
Resolved
Make available for inspection starboard quarter and conduct permanent repairs as found during continued inspections
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 16 June 2019
Resolved 29 May 2019
Resolution: O/O conducted permanenent repairs
02 - Structural Conditions › N/A - No Subsystem › Hull damage impairing seaworthiness
Issued 17 May 2019
Resolved
Conduct permanenet repairs to inboard strut braces on the port and starboard sides and make available for inspection
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 16 June 2019
Resolved 29 May 2019
Resolution: O/O conducted permanenet repairs
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 17 May 2019
Resolved
Make starboard chine available for inspection and submit repair plan as necessary
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 16 June 2019
Resolved 29 May 2019
Resolution: O/O completed permanent reapirs