MAURY USCG vessel records Sign in
← All vessels

OCEAN SPARTAN

OCEAN SPARTAN is a 1980 mobile offshore drilling unit. The Coast Guard has recorded 58 inspections since 1983, most recently in August 2022, along with 109 deficiencies — 1 with no resolution recorded —.

Records from 1983 to 2022. Most recent: inspection, 7 August 2022.

Built
1980
Last inspected
7 August 2022
Documentation
Not in the documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

8753263 View on MarineTraffic leaves Maury; a third-party site, nothing from it is stored here
HO9800
Flag
MARSHALL ISLANDS
—
Maury page id
psix-55016

Inspections, by type

…with no type recorded19
…past their stated due date1
Years with a record 24 calendar years (1983–2022)
The 58 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

This record may be incomplete: the most recent inspection recorded for this vessel was 4 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Offshore class in Maury's sources begin in 1978.

Documentation record

Tonnage as PSIX records it3675 - Regulatory (Subpart C or D), Gross Ton
2661 - Regulatory (Subpart C or D), Net Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.

Radio station licence

No FCC ship-station licence is recorded against this Official Number in the file of 6 September 2026. That is a fact about the licence file, not about the radio.

Inspected as a tow unit · 7

Inspection history · 58

7 August 2022 Type not recorded
No type recorded · Station Marblehead · USCG Great Lakes District (CGD-GL) · Activity 7527494
5 January 2009 Administrative Inspection
Administrative · Marine Safety Unit Port Arthur · USCG Heartland District (CGD-H) · Activity 3388671
30 March 2008 Administrative Inspection
Administrative · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 3173870
18 January 2008 Type not recorded
No type recorded · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 3132712
6 November 2007 Deficiency Check
Physical examination · Marine Safety Unit Port Arthur · USCG Heartland District (CGD-H) · Activity 3094156
10 October 2007 COC-MODU Annual
Type not classified · Marine Safety Unit Port Arthur · USCG Heartland District (CGD-H) · Activity 3077011
6 October 2006 COC-MODU Annual
Type not classified · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 2795266
30 January 2006 Type not recorded
No type recorded · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 2597738
14 December 2005 Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 2561546
12 December 2005 COC-MODU Annual
Type not classified · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 2550540
4 October 2004 COC-MODU Renew
Type not classified · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 2219230
21 October 2003 Certificate of Compliance
Administrative · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1911354
25 August 2003 Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1928696
14 December 2002 Administrative Inspection
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1718876
17 October 2002 Deficiency Check · Certificate of Compliance
Physical examination · Marine Safety Unit Brownsville · USCG Heartland District (CGD-H) · Activity 1692162
22 March 2002 Administrative Inspection
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1495873
6 March 2002 Administrative Inspection
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1491663
3 February 2002 Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1619969
17 November 2001 Administrative
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 771964
17 November 2001 Administrative
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 771966
8 September 2001 Administrative
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1073269
16 July 2001 Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 92217
16 June 2001 Administrative
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1065369
1 June 2001 Letter of Compliance (Initial/Renewal)
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1453902
2 June 2000 Letter of Compliance (Initial/Renewal)
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1420345
22 May 2000 Administrative
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 818631
28 February 2000 Administrative
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1046473
8 November 1999 Administrative
Administrative · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 801786
7 June 1999 Letter of Compliance (Initial/Renewal)
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1408318
31 March 1999 Administrative
Administrative · MSO Mobile · USCG Heartland District (CGD-H) · Activity 783468
19 February 1999 Type not recorded
No type recorded · MSO Mobile · USCG Heartland District (CGD-H) · Activity 203406
19 February 1999 Type not recorded
No type recorded · MSO Mobile · USCG Heartland District (CGD-H) · Activity 763903
18 February 1999 Type not recorded
No type recorded · MSO Mobile · USCG Heartland District (CGD-H) · Activity 186084
25 January 1999 Deficiency Check
Physical examination · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1122964
1 December 1998 Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 103077
12 November 1998 Administrative
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 804490
2 November 1998 Deficiency Check
Physical examination · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 804283
17 August 1998 Deficiency Check
Physical examination · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 796363
10 August 1998 Deficiency Check
Physical examination · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 800312
27 June 1998 Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 137683
10 June 1998 Letter of Compliance (Initial/Renewal)
Administrative · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1473356
23 June 1997 Administrative
Administrative · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 776814
12 June 1997 Letter of Compliance (Initial/Renewal)
Administrative · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1371910
30 December 1996 Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 89977
17 June 1996 Letter of Compliance (Initial/Renewal)
Administrative · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1467479
26 June 1995 Deficiency Check
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1192491
12 June 1995 Letter of Compliance (Initial/Renewal)
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1419435
16 June 1994 Letter of Compliance (Initial/Renewal)
Administrative · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1171882
28 March 1990 Certificate of Compliance
Administrative · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 925321
11 April 1989 Certificate of Compliance
Administrative · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 888949
28 April 1988 Certificate of Compliance
Administrative · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1193944
15 May 1987 Certificate of Compliance · Deficiency Check
Physical examination · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 1002406
16 October 1986 Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1317577
14 November 1984 Type not recorded
No type recorded · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 976749
17 July 1984 Type not recorded
No type recorded · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 1282030
30 July 1983 Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1277650
7 July 1983 Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1273334
7 June 1983 Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 972038

Deficiency record · 109

Fire Fighting › Structural - A Class Divisions › Fire Doors
Issued 6 November 2007 No resolution recorded
Class A boundary door from galley to exterior of vessel was inoperable.
Action required: 705 - Other - as specified
Due 9 January 2008 — due date passed with no resolution recorded
Fire Fighting › Fire Main › Material
Issued 10 October 2007 Resolved
Oyster shell lodged in fire nozzle indicating potential problem with sea strainers on fire pump(s).
Action required: 705 - Other - as specified
Due 29 October 2007
Resolved 26 October 2007
Resolution: Sea stainers pulled, inspected and replaced.
Fire Fighting › Structural - A Class Divisions › Doors
Issued 10 October 2007 Resolved
Class A door from galley to the exterior of the vessel, inoperable.
Action required: 705 - Other - as specified
Due 8 January 2008
Resolved 6 November 2007
Lifesaving › Lifeboat › Exhaust Pipe
Issued 12 December 2005 Resolved
Investigate and repair possible leak in Life Boat #2 exhaust.
Condition: Unknown
Due 31 December 2005
Resolved 12 December 2005
Resolution: Installed new exhaust pipe
Fire Fighting › Structural - A Class Divisions › Fire Doors
Issued 4 October 2004 Resolved
Provide written statement of fact stating that automatic door closures for galley and messdeck have been affixed.
Due 21 October 2004
Resolved 15 November 2004
Resolution: Recieved email from [name withheld] confirming automatic door closures are affixed
Accommodation/Occupational Safety › Occupational Safety › Deck Rail
Issued 4 October 2004 Resolved
Provide written statement of fact stating that the metallic tiedowns for the helo deck safety net have been installed.
Due 21 October 2004
Resolved 15 November 2004
Resolution: Recieved email from [name withheld], affirming the istallation of metal tiedowns
Fire Fighting
Issued 2 June 2000 Resolved
TROUBLESHOOT WHY ELECTROMAGNETIC HOLDBACKS ON FIRE DOORS DO NOT FUNCTION PROPERLY. PROVIDE DOCUMENTATION TO [name withheld].
Condition: Unknown
Due 20 June 2000
Resolved 20 June 2000
Lifesaving
Issued 2 June 2000 Resolved
RENEW OR REMOVE DETERIORATED IMMERSION SUITS.
Condition: Unknown
Due 20 June 2000
Resolved 20 June 2000
Fire Fighting
Issued 2 June 2000 Resolved
PROVIDE A TIME DELAY FOR THE HALON PILOT SYSTEM PROTECTING THE SCR ROOM, MUD PUMP ROOM, ENGINE ROOM AND COMPRESSOR ROOM. INSTALLATION TO BE MADE BY A CERTIFIED TECHNICIAN.
Condition: Unknown
Due 9 August 2000
Resolved 9 August 2000
Lifesaving
Issued 7 June 1999 Resolved
REPLACE ALL MISSING AND ROTTED FLOATS FOR LIFELINES ON BOTH LIFEBOATS.
Condition: Unknown
Due 7 June 1999
Resolved 7 June 1999
Lifesaving
Issued 7 June 1999 Resolved
CONDUCT 1.1 OPERATIONAL TEST OF ALL LIFEBOAT RELEASE GEARS OR ALTERNATE TEST SUBJECT TO APPROVAL OF THE LOCAL [name withheld] COMPLETED, CONDUCT MONTHLY VICE QUARTERLY IN WATER OPERATIONAL TEST OF ALL LIFEBOATS.
Condition: Unknown
Due 7 June 1999
Resolved 7 June 1999
Electrical
Issued 10 June 1998 Resolved
PROVIDE LABELING FOR BREAKERS IN ENGINE ROOM, 120VOLT DISTRIBUTION PANEL.
Condition: Unknown
Due 30 July 1998
Resolved 30 July 1998
Electrical
Issued 10 June 1998 Resolved
Provide E lighting for port and stbd life raft stations.
Condition: Unknown
Due 10 June 1998
Resolved 10 June 1998
Fire Fighting
Issued 10 June 1998 Resolved
Repair leaking nozzle at fire station #10.
Condition: Unknown
Due 30 July 1998
Resolved 30 July 1998
Fire Fighting
Issued 10 June 1998 Resolved
Provide door for main deck stair tower adj. to room 102. (A CLASS)
Condition: Unknown
Due 10 June 1998
Resolved 10 June 1998
Electrical
Issued 10 June 1998 Resolved
PROVE PROPER OPERATION OF LOW LUBE OIL SHUTDOWN FOR #1 GENERATOR.
Condition: Unknown
Due 30 July 1998
Resolved 30 July 1998
Engineering
Issued 10 June 1998 Resolved
PROVIDE MISSING PLUG FOR OIL FILL LINES ADJACENT TO GENERATORS NO.S 1,2, AND 3.
Condition: Unknown
Due 30 July 1998
Resolved 30 July 1998
Electrical
Issued 10 June 1998 Resolved
REPLACE ALL PLASTIC TIES WITH STEEL TIE WRAPS IN SHALE SHAKER AREA. SEVERALOVERHEAD WIRE RUNS FOR SEVERAL NEW WIRING INSTALLATIONS WERE IDENTIFIED AS HAVING PLASTIC TIES AND WERE IDENTIFIED HAVING TO BE IN COMPLIANCE WITH IEEE 45-1983, 20.5.
Condition: Unknown
Due 30 July 1998
Resolved 30 July 1998
Electrical
Issued 10 June 1998 Resolved
REMOVE ALL OVERHEAD PLASTIC WIRE TIES ADJACENT TO #4 GENERATOR AND SECURE USING IEEE-45-1983, 20.5 RECOMMENDED PRACTICE AS A GUIDE.
Condition: Unknown
Due 30 July 1998
Resolved 30 July 1998
Lifesaving
Issued 10 June 1998 Resolved
REMOVE HOLED/WORN IMMERSION SUIT FROM SERVICE.
Condition: Unknown
Due 30 July 1998
Resolved 30 July 1998
Fire Fighting
Issued 12 June 1997 Resolved
MAKE REQUIREDE REPAIRS TO FIREFIGHTING EQUIPMENT AS REQUIRED BY FIRE SERVICING RPT #35130798.
Condition: Unknown
Due 18 July 1997
Resolved 18 July 1997
Construction/Loadline
Issued 12 June 1997 Resolved
CROP AND RENEW WASTED UNDERDECK SUPPORTS FOR WINCH AT LIFEBOAT STATION #1
Condition: Unknown
Due 18 July 1997
Resolved 18 July 1997
Accommodation/Occupational Safety
Issued 12 June 1997 Resolved
RENEW WASTED RAILING, STBD SIDE IN WAY OF LIFE 1/3 TAKE ON STATION.
Condition: Unknown
Due 18 July 1997
Resolved 18 July 1997
Electrical
Issued 12 June 1997 Resolved
PROVIDE BLANKS FOR THE FOLLOWING LOCATIONS: LB2(2ND DECK), EFB5(CONTROL ROOM) AND LB3 (MAIN DECK).
Condition: Unknown
Due 18 July 1997
Resolved 18 July 1997
Construction/Loadline
Issued 12 June 1997 Resolved
PROVIDE DOG FOR UPPER SACK ROOM HATCH.
Condition: Unknown
Due 18 July 1997
Resolved 18 July 1997
Navigation
Issued 12 June 1997 Resolved
PROVE OPERATION OF PORT NAV LIGHTAND REPAIR WASTED STUFFING PIPES FOR BOTH SIDELIGHTS.
Condition: Unknown
Due 18 July 1997
Resolved 18 July 1997
Construction/Loadline
Issued 12 June 1997 Resolved
REPLACE BROKEN VALVES ON BILGE SYSTEM.
Condition: Unknown
Due 18 July 1997
Resolved 18 July 1997
Construction/Loadline
Issued 12 June 1997 Resolved
PERMANETLY AFFIX MOTOR PLATFORM STANCHION CONNECTION TO DECK IN WAY OF STBDLEG.
Condition: Unknown
Due 18 July 1997
Resolved 18 July 1997
Electrical
Issued 12 June 1997 Resolved
PROPERLY LABEL ALL EMERGENCY LIGHTING THROUGHOUT RIG.
Condition: Unknown
Due 18 July 1997
Resolved 18 July 1997
Engineering
Issued 12 June 1997 Resolved
REPAIR OR BLANK FUEL PIPING (PITTED AREA) AT STBD FUELING STATION.
Condition: Unknown
Due 18 July 1997
Resolved 18 July 1997
Engineering
Issued 12 June 1997 Resolved
REPAIR FUEL AND OIL LEAKS ON #1 GEN.
Condition: Unknown
Due 18 July 1997
Resolved 18 July 1997
Accommodation/Occupational Safety
Issued 12 June 1997 Resolved
PROVE PROPER OPERATION OF THE MUD PIT ROOM VENTILATION.
Condition: Unknown
Due 18 July 1997
Resolved 18 July 1997
Fire Fighting
Issued 12 June 1997 Resolved
PROVIDE PROPER BOOTS FOR FIREMANS OUTFITS.
Condition: Unknown
Due 18 July 1997
Resolved 18 July 1997
Engineering
Issued 12 June 1997 Resolved
LABEL EMERGENCY GEN FUEL SHUT OFF VALVE.
Condition: Unknown
Due 18 July 1997
Resolved 18 July 1997
Lifesaving
Issued 12 June 1997 Resolved
LABEL ALL ALARM LIGHTS NOT ALREADY LABELLED THROUGHOUT RIG.
Condition: Unknown
Due 18 July 1997
Resolved 18 July 1997
Electrical
Issued 12 June 1997 Resolved
PROPERLY LABEL ALL BREAKERS IN BREAKERPANELS THROUGHOUT RIG.
Condition: Unknown
Due 18 July 1997
Resolved 18 July 1997
Fire Fighting
Issued 17 June 1996 Resolved
REPLACE BOTH FIRE PUMP PRESSURE GAUGES.
Condition: Unknown
Due 7 November 1996
Resolved 7 November 1996
Fire Fighting
Issued 17 June 1996 Resolved
INSTALL A TIME DELAY SYSTEM AS NECESSARY FOR EACH HALON SYSTEM ON BOARD. SUBMIT SYSTEM MODIFICATIONS TO CLASS SOCIETY FOR PLAN APPROVAL PRIOR TO INSTALLATION.
Condition: Unknown
Due 17 June 1996
Resolved 17 June 1996
Documentation
Issued 17 June 1996 Resolved
PROVIDE ORIGINAL LICENSES FOR REQUIRED NUMBER OF ABLE SEAMAN AND LIFEBOATMEN ON BOARD RIG.
Condition: Unknown
Due 7 November 1996
Resolved 7 November 1996
Electrical
Issued 17 June 1996 Resolved
CORRECTLY LABEL AND PROVIDE BLANKING PLATES FOR DISTRIBUTION PANELS BY #4 GENERATOR AND IN EMERGENCY GENERATOR SPACE.
Condition: Unknown
Due 7 November 1996
Resolved 7 November 1996
Fire Fighting
Issued 17 June 1996 Resolved
REPAIR COUPLING TO FIRE PUMP #1.
Condition: Unknown
Due 7 November 1996
Resolved 7 November 1996
Fire Fighting
Issued 17 June 1996 Resolved
RELABEL SIGN DESIGNATING HALON ACTUATION CABINET.
Condition: Unknown
Due 7 November 1996
Resolved 7 November 1996
Lifesaving
Issued 17 June 1996 Resolved
LABEL ALL SIRENS, ALARM, & WARNING DEVICES.
Condition: Unknown
Due 7 November 1996
Resolved 7 November 1996
Electrical
Issued 17 June 1996 Resolved
REPAIR INOPERABLE LOUVERS TO EMERGENCY GENERATOR SPACE.
Condition: Unknown
Due 7 November 1996
Resolved 7 November 1996
Fire Fighting
Issued 17 June 1996 Resolved
RECHARGE HALON CYLINDER IN STOREROOM/ELECTRICIAN'S SHOP.
Condition: Unknown
Due 7 November 1996
Resolved 7 November 1996
Lifesaving
Issued 17 June 1996 Resolved
PROVIDE DIRT CAPS ON ALL EYE WASH STATIONS.
Condition: Unknown
Due 7 November 1996
Resolved 7 November 1996
Documentation
Issued 17 June 1996 Resolved
PROVIDE FINAL COPIES OF FOLLOWING CERTIFICATES: IMO MODU CODE, IOPP, & LOADLINE.
Condition: Unknown
Due 17 June 1996
Resolved 17 June 1996
Lifesaving
Issued 12 June 1995 Resolved
PROVIDE PROPER ALARM TO PURGE SYSTEM ON VENT/GAS PANEL WHICH WILL ALERT DRILLER.
Condition: Unknown
Due 26 June 1995
Resolved 26 June 1995
Navigation
Issued 12 June 1995 Resolved
PROVIDE PROPER SIGNAL SEQUENCE ON FOG SIGNAL FOR U.S. WATERS. (2 SEC. ON 18SEC. OFF)
Condition: Unknown
Due 13 June 1995
Resolved 13 June 1995
Fire Fighting
Issued 12 June 1995 Resolved
MAKE BOTH PIT ROOM DOORS GAS TIGHT.
Condition: Unknown
Due 14 July 1995
Resolved 14 July 1995
Lifesaving
Issued 12 June 1995 Resolved
PROVIDE PROPER PURGE TO WMCO ROLLING TAPE BOX ON DRILLING CONSOLE.
Condition: Unknown
Due 13 June 1995
Resolved 13 June 1995
Engineering
Issued 16 June 1994 Resolved
REPAIR OWS NO LATER THAN 16JUL94.
Condition: Unknown
Due 16 July 1994
Resolved 12 July 1994
Documentation
Issued 16 June 1994 Resolved
RENEW LETTER OF COMPLIANCE NO LATER THAN 16JUN95.
Condition: Unknown
Due 16 June 1994
Resolved 16 June 1994
Engineering
Issued 11 April 1989 Resolved
PRESSURE VESSEL NOT INSPECTED WITHIN 24 MONTHS OF EXAM. REQUIRED TO BE INSPECTED INTERNALLY OR HYDRO TESTED.
Condition: Unknown
Due 11 April 1989
Resolved 11 April 1989
Lifesaving
Issued 28 April 1988 Resolved
REPLACE OR SHOW EVIDENCE OF A SATISFACTORY NON DESTRUCTIVE TEST OF THE WIRE ROPE UTILIZED AT BOTH OF THE DAVIT LAUNCH LIFERAFT STATIONS. PER IMO 10.1 (46 CFR 107.239).
Condition: Unknown
Due 28 April 1988
Resolved 28 April 1988
Electrical
Issued 28 April 1988 Resolved
REMOVE OR PROVE EX LOG EQUIP LOCATED IN MUD PIT ROOM SATISFACTORY FOR HAZARDOUS LOCATION. IF IT IS PROVEN TO BE SATISFACTORY APPROPRIATELY MOUNT PER IMO 6.6. (46 CFR 111.105)
Condition: Unknown
Due 28 April 1988
Resolved 28 April 1988
Electrical
Issued 28 April 1988 Resolved
PROVIDE EYS FITTINGS FOR ALL LEVEL INDICATE DEVICES IN MUD PIT. PER IMO 6.6 (46 CFR 111.105)
Condition: Unknown
Due 28 April 1988
Resolved 28 April 1988
Lifesaving
Issued 15 May 1987 Resolved
LAUNCH BOTH LIFEBOATS AND TEST RETRIVAL SYSTEM TO THE SATISFACTION OF THE ATTENDING CG INSPECTOR.
Condition: Unknown
Due 15 May 1987
Resolved 15 May 1987
Lifesaving
Issued 15 May 1987 Resolved
CONDUCT TEST OF EMERGENCY LIGHTING AND POWER SYSTEM TO THE SATISFACTION OF THE ATTENDING CG INSPECTOR.
Condition: Unknown
Due 15 May 1987
Resolved 15 May 1987
Fire Fighting
Issued 15 May 1987 Resolved
PROVIDE DOCUMENTATION OF/OR PROVIDE SERVICING FOR FIXED, SEMIPORTABLE AND PORTABLE FIRE FIGHTING SYSTEMS.
Condition: Unknown
Due 15 May 1987
Resolved 15 May 1987
Lifesaving
Issued 15 May 1987 Resolved
PROVIDE EPIRB WITH CURRENT BATTERY.
Condition: Unknown
Due 15 May 1987
Resolved 15 May 1987
Accommodation/Occupational Safety
Issued 15 May 1987 Resolved
STORE FOOD STUFFS OFF DECK IN PANTRY.
Condition: Unknown
Due 15 May 1987
Resolved 15 May 1987
Accommodation/Occupational Safety
Issued 15 May 1987 Resolved
PROVIDE COVER FOR ELECTRICAL CONNECTION RECEPTACLE ON DISHWASHER.
Condition: Unknown
Due 15 May 1987
Resolved 15 May 1987
Accommodation/Occupational Safety
Issued 15 May 1987 Resolved
CLEAN DECK, RANGE HOODS AND COUNTER TOPS OF GREASE IN GALLEY.
Condition: Unknown
Due 15 May 1987
Resolved 15 May 1987
Electrical
Issued 15 May 1987 Resolved
PROVIDE GLOBES FOR INTERIOR LIGHTS WHERE MISSING.
Condition: Unknown
Due 15 May 1987
Resolved 15 May 1987
Documentation
Issued 15 May 1987 Resolved
PROVIDE ROSTER OF ASSIGNED PERSONNEL FOR EACH LIFEBOAT/LIFERAFT TO DESIGNATE LIFEBOATMEN.
Condition: Unknown
Due 15 May 1987
Resolved 15 May 1987
Documentation
Issued 15 May 1987 Resolved
DESIGNATE CRANE OPERATORS IN WRITING.
Condition: Unknown
Due 15 May 1987
Resolved 15 May 1987
Lifesaving
Issued 15 May 1987 Resolved
POST HAZARDOUS LOCATIONS PLAN IN AREAS ACCESSIBLE TO CREW.
Condition: Unknown
Due 15 May 1987
Resolved 15 May 1987
Documentation
Issued 15 May 1987 Resolved
DESIGNATE PERSON IN CHARGE IN WRITING.
Condition: Unknown
Due 15 May 1987
Resolved 15 May 1987
Documentation
Issued 15 May 1987 Resolved
PROVIDE MEANS TO INFORM NEWLY ARRIVING PERSONNEL OF THIER EMERGENCY STATIONS AND LIFEBOAT ASSIGNMENTS.
Condition: Unknown
Due 15 May 1987
Resolved 15 May 1987
Lifesaving
Issued 15 May 1987 Resolved
CONDUCT FIRE AND BOAT DRILL TO THE SATISFACTION OF THE ATTENDING COAST GUARD INSPECTOR.
Condition: Unknown
Due 15 May 1987
Resolved 15 May 1987
Documentation
Issued 15 May 1987 Resolved
PROVIDE A LOG BOOK FOR ENTERING NOTATIONS OF REQUIRED TESTS & INSPECTIONS.
Condition: Unknown
Due 15 May 1987
Resolved 15 May 1987
Lifesaving
Issued 15 May 1987 Resolved
PROVIDE DOCUMENTATION OF/OR PROVIDE SERVICING FOR HYDROSTATIC RELEASES FOR LIFERAFTS.
Condition: Unknown
Due 15 May 1987
Resolved 15 May 1987
Fire Fighting
Issued 15 May 1987 Resolved
PROVIDE TWO FULLY EQUIPPED FIREMAN'S OUTFITS.
Condition: Unknown
Due 15 May 1987
Resolved 15 May 1987
Unknown
Issued 15 May 1987 Resolved
PROVIDE ONE STATION BILL VICE SEVERAL TYPES, WHICH ACCURATELY DEPICTS DUTY ASSIGNMENTS.
Condition: Unknown
Due 15 May 1987
Resolved 15 May 1987
Lifesaving
Issued 17 July 1984 Resolved
[withheld — contains personal information; the deficiency system, dates, and resolution status are shown above]
Condition: Unknown
Due 17 July 1984
Resolved 17 July 1984
Unknown
Issued 7 July 1983 Resolved
THE FOLLOWING DEFICIENCIES PERTAIN TO THE FOREIGN MODU SALENERGY V, PANAMANIAN REGISTRY 12007-82.
Condition: Unknown
Due 7 August 1983
Resolved 7 July 1983
Unknown
Issued 7 July 1983 Resolved
PROVIDE "LOSS OF PURGE AIR" ALARM FOR DRILLER'S CONSOLE.
Condition: Unknown
Due 7 August 1983
Resolved 7 July 1983
Unknown
Issued 7 July 1983 Resolved
PROVIDE INDENTIFICATION LABELS TO EMERGENCY SIGNALS (ROTATING LIGHTS, HORNSETC.)IN MUD PIT ROOM, MUD PUMP ROOM, MACHINERY SPACE & AIR COMPRESSOR ROOM.
Condition: Unknown
Due 7 August 1983
Resolved 7 July 1983
Unknown
Issued 7 July 1983 Resolved
PROVIDE ASME APPROVED 120 PSI RELIEF VALVES FOR DRILL FLOOR AIR RECEIVER; AIR RECEIVER IN AIR COMPRESSOR ROOM, & AIR RECEIVER IN MANCHINERY ROOM.
Condition: Unknown
Due 7 August 1983
Resolved 7 July 1983
Unknown
Issued 7 July 1983 Resolved
PROVIDE ONE (1) ASME APPROVED RELIEF VALVE (44 PSI) TO BULK AIR RECEIVER IN AIR COMPRESSOR ROOM.
Condition: Unknown
Due 7 August 1983
Resolved 7 July 1983
Unknown
Issued 7 June 1983 Resolved
THE FOLLOWIN DEFICIENCIES PERTAIN TO THE VESSEL SALEVERGY V, PANAMANIAN REGISTRY 12007-82
Condition: Unknown
Due 7 July 1983
Resolved 7 June 1983
Lifesaving
Issued 7 June 1983 Resolved
PROVIDE 1 FLASHLIGHT 3 SPARE BATTERIES, AND 2 SPARE BULBS IN EACH LIFEBOAT.
Condition: Unknown
Due 7 July 1983
Resolved 7 June 1983
Fire Fighting
Issued 7 June 1983 Resolved
PROVIDE ONE (1) 3 CELL EXPLOSION PROOF FLASHLIGHT FOR EACH FIREMAN'S OUTFIT.
Condition: Unknown
Due 7 July 1983
Resolved 7 June 1983
Lifesaving
Issued 7 June 1983 Resolved
PROVIDE ONE (1) ADDITIONAL RING LIFEBUOY TO TOTAL 8 ON BOARD VESSEL.
Condition: Unknown
Due 7 July 1983
Resolved 7 June 1983
Lifesaving
Issued 7 June 1983 Resolved
PROVIDE TWO (2) SMOKE BUOYS ON TWO (2) EXISTING RING LIFE BUOYS WITH WATER-LIGHTS.
Condition: Unknown
Due 7 July 1983
Resolved 7 June 1983
Lifesaving
Issued 7 June 1983 Resolved
PROVIDE TWO (2) BUOYANT LINES ON TWO (2) RING LIFE BUOY OF A LENGTH 1-1/2 TIMES THE DISTANCE TO THE WATER.
Condition: Unknown
Due 7 July 1983
Resolved 7 June 1983
Fire Fighting
Issued 7 June 1983 Resolved
REPAIR OR REPLACE EXISTING EXPLOSIVE GAS METER AND PROVIDE ONE ADDITIONAL SUCH UNIT ON BOARD.
Condition: Unknown
Due 7 July 1983
Resolved 7 June 1983
Fire Fighting
Issued 7 June 1983 Resolved
PROVIDE ONE (1) ADDITIONAL SELF-CONTAINED BREATHING APPARATUS FOR SECOND FIREMAN'S OUTFIT.
Condition: Unknown
Due 7 July 1983
Resolved 7 June 1983
Electrical
Issued 7 June 1983 Resolved
DEMONSTRATE PROPER OPERATION OF OVERSPEED TRIP, AND LOW LUBE OIL AND HIGH WATER TEMPERATURE ALARMS ON ENGINES NR. 1, 2 AND 3.
Condition: Unknown
Due 7 July 1983
Resolved 7 June 1983
Electrical
Issued 7 June 1983 Resolved
ITEMS 9 THRU 16 APPLY TO THE DRILL FLOOR HAZARDOUS AREA.
Condition: Unknown
Due 7 July 1983
Resolved 7 June 1983
Accommodation/Occupational Safety
Issued 7 June 1983 Resolved
PROVIDE PRESSURE RELIEF VALVE SET AT 120 PSI FOR RIG AIR TANK IN MACHINERY ROOM AND DEMONSTRATE PROPER OPERATION OF RELIEF VALVES ON 4 RIG AIR TANKS.
Condition: Unknown
Due 7 July 1983
Resolved 7 June 1983
Accommodation/Occupational Safety
Issued 7 June 1983 Resolved
MAKE FOUR RIG AIR RECEIVERS AVAILABLE FOR INTERNAL EXAMINATION.
Condition: Unknown
Due 7 July 1983
Resolved 7 June 1983
Electrical
Issued 7 June 1983 Resolved
PROVIDE EYS SEALS ON ALL LIGHT JUNCTION BOXES, THE PA HORN, THE LIGHT OVER THE CHOKE CONTROL AND AT BOTTOM OF LARGE SWITCH PANELS.
Condition: Unknown
Due 7 July 1983
Resolved 7 June 1983
Electrical
Issued 7 June 1983 Resolved
REMOVE SPLICE IN WIRE TO PA HORN.
Condition: Unknown
Due 7 July 1983
Resolved 7 June 1983
Electrical
Issued 7 June 1983 Resolved
REMOVE DEAD END CABLES BY ANNUNCIATOR PANEL AND ABOVE SWITCH PANELS AFT.
Condition: Unknown
Due 7 July 1983
Resolved 7 June 1983
Electrical
Issued 7 June 1983 Resolved
PROVIDE MISSING BOLTS AND TIGHTEN LOOSE BOLTS IN GAITRONICS PHONE BOX AND IN SWITCH PANELS.
Condition: Unknown
Due 7 July 1983
Resolved 7 June 1983
Electrical
Issued 7 June 1983 Resolved
PROVIDE CHICO AND A PLUG IN EYS SEAL FOR GENERAL ALARM BELL AFT OF DRILLERSCONSOLE.
Condition: Unknown
Due 7 July 1983
Resolved 7 June 1983
Electrical
Issued 7 June 1983 Resolved
PROVIDE CHICO IN DIVISION 2 EYS SEAL ON ALARM HORN ABOVE SWITCH PANELS.
Condition: Unknown
Due 7 July 1983
Resolved 7 June 1983
Electrical
Issued 7 June 1983 Resolved
REMOVE OR REPLACE NON-EXPLOSION PROOF OUTLET BY ANNUNCIATOR PANEL WITH TYPESUITABLE FOR HAZARDOUS AREA.
Condition: Unknown
Due 7 July 1983
Resolved 7 June 1983
Electrical
Issued 7 June 1983 Resolved
PROVIDE LOSS OF PURGE ALARM FOR DRILLER'S CONSOLE.
Condition: Unknown
Due 7 July 1983
Resolved 7 June 1983
Electrical
Issued 7 June 1983 Resolved
PROVIDE DOCUMENTATION AS TO EXPLOSION-PROOF DESIGN OF FITTINGS ON PORT BULKHEAD, SHALE SHAKER HAZARDOUS AREA, OR REPLACE WITH SUITABLE TYPE.
Condition: Unknown
Due 7 July 1983
Resolved 7 June 1983
Electrical
Issued 7 June 1983 Resolved
IN THE SHALE SHAKER AREA PROVIDE EYS SEALS ON PORT SHAKER MOTOR, PA HORN, AND ALL LIGHTS.
Condition: Unknown
Due 7 July 1983
Resolved 7 June 1983
Electrical
Issued 7 June 1983 Resolved
IN THE MUD PITS HAZARDOUS AREA PROVIDE EYS SEALS ON ALL LIGHT FIXTURES AS REQUIRED.
Condition: Unknown
Due 7 July 1983
Resolved 7 June 1983
Electrical
Issued 7 June 1983 Resolved
PROVIDE VENTILATION SUCH THAT A NEGATIVE PRESSURE EXISTS BETWEEN THE MUD PITS AND THE PUMP ROOM AND PROVIDE LOSS-OF-VENT ALARM AT MANNED STATION.
Condition: Unknown
Due 7 July 1983
Resolved 7 June 1983
Electrical
Issued 7 June 1983 Resolved
MAKE DOORS TO MUD PITS SELF-CLOSING AND GAS-TIGHT WITH NO LATCHBACK DEVICES
Condition: Unknown
Due 7 July 1983
Resolved 7 June 1983
Electrical
Issued 7 June 1983 Resolved
IN LIEU OF ITEMS 20 AND 21, MAKE THE MUD PUMP ROOM ELECTRICAL FITTINGS ALL SUITABLE FOR A HAZARDOUS AREA.
Condition: Unknown
Due 7 July 1983
Resolved 7 June 1983
Documentation
Issued 7 June 1983 Resolved
START AND MAINTAIN A VESSEL LOG IN ACCORDANCE WITH 46 CFR 109.433.
Condition: Unknown
Due 7 July 1983
Resolved 7 June 1983
Accommodation/Occupational Safety
Issued 7 June 1983 Resolved
REMOVE OR DISABLE LOCKS ON ALL DOORS IN ACCOMMODATION SPACES THAT SERVE AS MEANS OF ESCAPE.
Condition: Unknown
Due 7 July 1983
Resolved 7 June 1983

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.