MAURY USCG vessel records Sign in
← All vessels

DIVEMASTER

DIVEMASTER is a 1978 passenger vessel (inspected). The Coast Guard has recorded 34 inspections since 1985, most recently in February 2018, along with 73 deficiencies and 1 casualty investigation in 2005.

Records from 1985 to 2018. Most recent: inspection, 12 February 2018.

Built
1978
Last inspected
12 February 2018
Documentation
Not in the documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

WDD7761
Flag
UNITED STATES
367190960 (licence lapsed)
Maury page id
psix-55021

Inspections, by type

…with no type recorded2
Years with a record 24 calendar years (1985–2018)
The 34 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

This record may be incomplete: the most recent inspection recorded for this vessel was 8 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 1977.

Documentation record

Tonnage as PSIX records it18 - Regulatory (Subpart C or D), Gross Ton
12 - Regulatory (Subpart C or D), Net Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.

Radio station licence

WDD7761MMSI 367190960 · expired · compulsorily equipped · granted 31 May 2007, cancelled 5 August 2017
WCW6636MMSI not assigned · expired · compulsorily equipped · granted 14 June 1996, cancelled 19 August 2006
FCC Universal Licensing System ship-station file of 6 September 2026, matched to this hull on its US Official Number. Status and dates are the file’s own. The licensee is not read from the file and is not shown. A lapsed licence’s MMSI is still the number the vessel transmitted under while it was valid.

Inspection history · 34

12 February 2018 Administrative Inspection
Administrative · Sector Mobile · USCG Heartland District (CGD-H) · Activity 6353825
24 May 2007 COI Inspection · Deficiency Check
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 2914093
9 May 2007 Internal Structural Exam · Hull Examination · Deficiency Check
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 2914091
5 April 2007 Administrative Inspection · Simplified Stability Test
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 2902173
16 March 2007 Administrative Inspection
Administrative · Sector Mobile · USCG Heartland District (CGD-H) · Activity 2889179
19 January 2007 In-Service Inspection · Administrative Inspection
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 2862213
16 August 2006 Re-Inspection
Physical examination · Sector Northern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 2751831
28 May 2005 Type not recorded
No type recorded · Sector Northern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 2461462
6 May 2005 Hull Examination
Physical examination · MSO SAULT STE MARIE · USCG Great Lakes District (CGD-GL) · Activity 2350202
14 July 2004 Simplified Stability Test · Examination of Repairs · Periodic Inspection
Physical examination · MSO SAULT STE MARIE · USCG Great Lakes District (CGD-GL) · Activity 2133054
12 June 2003 Periodic Inspection
Physical examination · MSO SAULT STE MARIE · USCG Great Lakes District (CGD-GL) · Activity 1816640
30 May 2002 Deficiency Check · COI Inspection
Physical examination · MSO SAULT STE MARIE · USCG Great Lakes District (CGD-GL) · Activity 1630494
22 May 2001 COI Inspection
Physical examination · MSO SAULT STE MARIE · USCG Great Lakes District (CGD-GL) · Activity 1461409
4 June 2000 Re-Inspection · Hull Examination
Physical examination · MSO SAULT STE MARIE · USCG Great Lakes District (CGD-GL) · Activity 1393427
1 July 1999 Re-Inspection
Physical examination · MSO SAULT STE MARIE · USCG Great Lakes District (CGD-GL) · Activity 1369290
5 June 1998 COI Inspection
Physical examination · MSO SAULT STE MARIE · USCG Great Lakes District (CGD-GL) · Activity 792974
12 June 1997 Administrative
Administrative · MSO SAULT STE MARIE · USCG Great Lakes District (CGD-GL) · Activity 775683
11 June 1997 Re-Inspection
Physical examination · MSO SAULT STE MARIE · USCG Great Lakes District (CGD-GL) · Activity 778020
22 May 1996 Re-Inspection · Hull Examination
Physical examination · MSO SAULT STE MARIE · USCG Great Lakes District (CGD-GL) · Activity 1186240
20 June 1995 Plan Review "T" Boat · COI Inspection
Physical examination · MSO SAULT STE MARIE · USCG Great Lakes District (CGD-GL) · Activity 877550
30 June 1994 Re-Inspection
Physical examination · MSO SAULT STE MARIE · USCG Great Lakes District (CGD-GL) · Activity 863595
23 June 1993 Re-Inspection
Physical examination · MSO SAULT STE MARIE · USCG Great Lakes District (CGD-GL) · Activity 1152617
30 June 1992 COI Inspection
Physical examination · MIO ST. IGNACE · USCG Great Lakes District (CGD-GL) · Activity 944717
17 June 1991 Re-Inspection
Physical examination · MIO ST. IGNACE · USCG Great Lakes District (CGD-GL) · Activity 1247844
22 May 1991 Hull Examination
Physical examination · MIO ST. IGNACE · USCG Great Lakes District (CGD-GL) · Activity 1228266
14 June 1990 Re-Inspection
Physical examination · MIO ST. IGNACE · USCG Great Lakes District (CGD-GL) · Activity 912857
24 May 1989 COI Inspection
Physical examination · MIO ST. IGNACE · USCG Great Lakes District (CGD-GL) · Activity 1353012
25 May 1988 Re-Inspection
Physical examination · MIO ST. IGNACE · USCG Great Lakes District (CGD-GL) · Activity 897048
27 May 1987 Re-Inspection
Physical examination · MIO ST. IGNACE · USCG Great Lakes District (CGD-GL) · Activity 1322507
3 July 1986 Deficiency Check
Physical examination · MIO ST. IGNACE · USCG Great Lakes District (CGD-GL) · Activity 998566
29 May 1986 COI Inspection
Physical examination · MIO ST. IGNACE · USCG Great Lakes District (CGD-GL) · Activity 1302586
24 April 1986 Credit Drydock
Administrative · MSO MILWAUKEE · USCG Great Lakes District (CGD-GL) · Activity 1296585
27 August 1985 Deficiency Check
Physical examination · MSO MILWAUKEE · USCG Great Lakes District (CGD-GL) · Activity 1293582
8 July 1985 Type not recorded
No type recorded · MSO MILWAUKEE · USCG Great Lakes District (CGD-GL) · Activity 1291502

Deficiency record · 73

Lifesaving › Lifefloat › Markings
Issued 24 May 2007 Resolved
Properly mark the 22 person life float in accordance with 46 CFR 185.604.
Action required: 705 - Other - as specified
Due 24 June 2007
Resolved 13 June 2007
Resolution: Life float was properly marked.
Lifesaving › Lifefloat › Floating Electric Waterlight
Issued 24 May 2007 Resolved
Prove proper operation of the water light for the 22 person life float in accordance with 46 CFR 180.175.
Action required: 705 - Other - as specified
Due 24 June 2007
Resolved 13 June 2007
Resolution: Water light operated properly.
Lifesaving › Lifefloat › Paddle
Issued 24 May 2007 Resolved
Properly mark and attach the paddles to the 22 person life floats and provide a 4' paddle for the 22 person life float in accordance with 46 CFR 180.175 and 185.604.
Action required: 705 - Other - as specified
Due 24 June 2007
Resolved 13 June 2007
Resolution: Paddles were all accounted for and properly marked and attached.
Lifesaving › Lifefloat › Serviceable
Issued 24 May 2007 Resolved
Properly repair the hole in the 12 person life float in accordance with 46 CFR 180.205.
Action required: 705 - Other - as specified
Due 24 June 2007
Resolved 13 June 2007
Resolution: Hole was properly repaired.
Lifesaving › Lifefloat › Paddle
Issued 24 May 2007 Resolved
Properly mark and attach the paddles to the 12 person life float in accordance with 46 CFR 180.175 and 185.604.
Action required: 705 - Other - as specified
Due 24 June 2007
Resolved 13 June 2007
Resolution: Paddles were properly marked an attached.
Lifesaving › Lifebuoys › Buoyant Lifeline
Issued 24 May 2007 Resolved
Properly mark the life ring and attach the lifeline to the life ring in accordance with 46 CFR 180.70 and 185.604.
Action required: 705 - Other - as specified
Due 24 June 2007
Resolved 13 June 2007
Resolution: Life ring was properly marked and lifeline was attached.
Lifesaving › Lifebuoys › Self-igniting Lights
Issued 24 May 2007 Resolved
Provide approved battery for the water light to the life ring in accordance with 46 CFR 180.10.
Action required: 705 - Other - as specified
Due 24 June 2007
Resolved 13 June 2007
Resolution: Water light included approved battery.
Communications › Radio Communications › EPIRB
Issued 24 May 2007 Resolved
Provide an EPIRB and proof of registration in accordance with 46 CFR 180.64.
Action required: 705 - Other - as specified
Due 24 June 2007
Resolved 13 June 2007
Resolution: Registered EPIRB was provided.
Construction/Loadline › Markings › Vessel Name/Home Port
Issued 24 May 2007 Resolved
Properly mark the hull with the vessel name and homeport in accordance with 46 CFR 185.602.
Action required: 705 - Other - as specified
Due 24 June 2007
Resolved 13 June 2007
Resolution: Hull was marked with the vessels name and homeport.
Accommodation/Occupational Safety › Occupational Safety › Guards for Exposed Hazards
Issued 24 May 2007 Resolved
Replace the broken window in the pilothouse in accordance with 46 CFR 177.1010.
Action required: 705 - Other - as specified
Due 24 June 2007
Resolved 25 July 2007
Resolution: Window was replaced with safety glass.
Accommodation/Occupational Safety › Occupational Safety › Storm Rail
Issued 24 May 2007 Resolved
Provide signs prohibiting passengers from going on the bow in accordance with 46 CFR 177.900.
Action required: 705 - Other - as specified
Due 24 June 2007
Resolved 13 June 2007
Resolution: Prohibition signs were provided.
Lifesaving › Lifejacket/PFD (General) › Quantity
Issued 24 May 2007 Resolved
Provide four child lifejackets in accordance with 46 CFR 180.71.
Action required: 705 - Other - as specified
Due 24 June 2007
Resolved 25 July 2007
Resolution: 4 child lifejackets were provided.
Lifesaving › Lifejacket/PFD (General) › Marking
Issued 24 May 2007 Resolved
Provide a lifejacket donning placard for both types of lifejackets on board in accordance with 46 CFR 185.516.
Action required: 705 - Other - as specified
Due 24 June 2007
Resolved 25 July 2007
Resolution: Lifejacket donning placard was provided.
Stability › Watertight Integrity › General
Issued 24 May 2007 Resolved
Prove proper operation of the lazarette hatch and properly attach to the vessel in accordance with 46 CFR 179.360.
Action required: 705 - Other - as specified
Due 24 June 2007
Resolved 13 June 2007
Resolution: Hatch operated properly and was attached to the vessel.
Engineering › Fuel Oil Service System › Piping
Issued 24 May 2007 Resolved
Provide a fuel cap for the starboard fuel fill line in accordance with 46 CFR 176.800.
Action required: 705 - Other - as specified
Due 24 June 2007
Resolved 13 June 2007
Resolution: Fuel cap was provided.
Fire Fighting › Portable CO2 Fire Extinguisher › Number
Issued 24 May 2007 Resolved
Provide 1 B-II fire extinguisher in accordance with 46 CFR 181.500.
Action required: 705 - Other - as specified
Due 24 June 2007
Resolved 13 June 2007
Resolution: 1 B-II extinguisher was provided.
Engineering › Steering Gear System › Hydraulic Hose
Issued 24 May 2007 Resolved
Properly support the hydraulic lines for the steering system in accordance with 46 CFR 176.800.
Action required: 705 - Other - as specified
Due 24 June 2007
Resolved 25 July 2007
Resolution: Hydraulic lines were supported.
Engineering › Fuel Oil Service System › Valve
Issued 24 May 2007 Resolved
Properly label the emergency fuel shut-off for the port and starboard aft fuel tanks and replace the handles in accordance with 46 CFR 185.608 and 176.800.
Action required: 705 - Other - as specified
Due 24 June 2007
Resolved 13 June 2007
Resolution: Emergency fuel shut-off was properly labeled.
Accommodation/Occupational Safety › Ventilation › General
Issued 24 May 2007 Resolved
Prove proper operation of the forced air ventilation for the engine room or remove in accordance with 46 CFR 176.800.
Action required: 705 - Other - as specified
Due 24 June 2007
Resolved 13 June 2007
Resolution: Forced air ventilation system was removed.
Electrical › Electrical Distribution System (service) › Wiring
Issued 24 May 2007 Resolved
Remove all dead end wires in the engine room in accordance with 46 CFR 183.340.
Action required: 705 - Other - as specified
Due 24 June 2007
Resolved 25 July 2007
Resolution: Dead end wires have been removed.
Engineering › Sea-water System (primary cooling) › Piping
Issued 24 May 2007 Resolved
Properly support the raw water cooling lines for both main engines in accordance with 46 CFR 176.800.
Action required: 705 - Other - as specified
Due 24 June 2007
Resolved 25 July 2007
Resolution: Cooling lines have been supported.
Electrical › Electric Supply System (service) › Battery Installation
Issued 24 May 2007 Resolved
Properly stow the batteries in battery boxes for both main engine starting batteries in accordance with 46 CFR 183.350.
Action required: 705 - Other - as specified
Due 24 June 2007
Resolved 13 June 2007
Resolution: Batteries have been stowed in their boxes.
Operations/Management › Bilge/Bilge System Management › Control of Oil Mixtures
Issued 24 May 2007 Resolved
Remove all used oil filters from the engine room in accordance with 46 CFR 176.800.
Action required: 705 - Other - as specified
Due 24 June 2007
Resolved 25 July 2007
Resolution: Used oil filters have been removed.
Accommodation/Occupational Safety › Occupational Safety › Guards for Exposed Hazards
Issued 24 May 2007 Resolved
Provide guards over rotating machinery in the engine room in accordance with 46 CFR 177.960.
Action required: 705 - Other - as specified
Due 24 June 2007
Resolved 25 July 2007
Resolution: A gate has been installed in the engine room prohibiting access to the moving parts while the engines are running.
Electrical › Electrical Distribution System (service) › Switch
Issued 24 May 2007 Resolved
Provide a battery disconnect switch between the batteries and starters for both main engines in accordance with 46 CFR 183.380.
Action required: 705 - Other - as specified
Due 24 June 2007
Resolved 25 July 2007
Resolution: Battery disconnect switches have been installed.
Accommodation/Occupational Safety › Occupational Safety › Portable Electric Equipment/Appliances
Issued 24 May 2007 Resolved
Properly stow all loose gear throughout the vessel and make ready for inspection in accordance with 46 CFR 176.800.
Action required: 705 - Other - as specified
Due 24 June 2007
Resolved 13 June 2007
Resolution: All loose gear has been stowed.
Documentation › Certificates/Documents › FCC SSL
Issued 24 May 2007 Resolved
Provide FCC station license, safety certificate, and marine radio operator permit in accordance with 46 CFR 184.502.
Action required: 705 - Other - as specified
Due 24 June 2007
Resolved 25 July 2007
Resolution: All FCC certificates have been provided.
Personnel › Certificates/Documents/Licenses › License, Master
Issued 24 May 2007 Resolved
Provide a master's license in accordance with 46 CFR 185.402.
Action required: 705 - Other - as specified
Due 24 June 2007
Resolved 25 July 2007
Resolution: Master''s license provided.
Navigation › Piloting/Steering › US Coast Pilot
Issued 24 May 2007 Resolved
Provide updated charts, and current Coast Pilot [name withheld], Tide tables, and Tidal Current tables in accordance with 46 CFR 184.420.
Action required: 705 - Other - as specified
Due 24 June 2007
Resolved 13 June 2007
Resolution: All updated editions of the navigation publications have been provided.
Operations/Management › Drills/Instruction › Man Overboard Recovery
Issued 24 May 2007 Resolved
Properly post the emergency instruction list in accordance with 46 CFR 185.510.
Action required: 705 - Other - as specified
Due 24 June 2007
Resolved 13 June 2007
Resolution: Emergency instructions have been posted.
Operations/Management › Drills/Instruction › Making Voice Radio Distress Call
Issued 24 May 2007 Resolved
Properly post the emergency broadcast placard in accordance with 46 CFR 184.506.
Action required: 705 - Other - as specified
Due 24 June 2007
Resolved 13 June 2007
Resolution: Emergency broadcast placard has been posted.
Engineering › Bilge Water Management System › Valve
Issued 9 May 2007 Resolved
Provide positive shut-off valves at the hull penetration for all independent bilge pump overboard discharges in accordance with 46 CFR 182.520.
Action required: 705 - Other - as specified
Due 9 June 2007
Resolved 24 May 2007
Resolution: provided positive shut-off valves at the hull penetration
Engineering › Diesel Engine (propulsion-reduction gear) › Governor
Issued 9 May 2007 Resolved
Replace the throttle cable for the starboard engine in accordance with 46 CFR 176.804.
Action required: 705 - Other - as specified
Due 9 June 2007
Resolved 24 May 2007
Resolution: Replaced the throttle cable
Stability › Watertight Integrity › General
Issued 9 May 2007 Resolved
Replace the hinges for the hatch cover to the collision forepeak space in accordance with 46 CFR 179.360.
Action required: 705 - Other - as specified
Due 9 June 2007
Resolved 24 May 2007
Resolution: Replaced the hinges for the forepeak hatch cover
Stability › Watertight Integrity › Coaming
Issued 9 May 2007 Resolved
Provide a 6 inch coaming on the hatch to the forepeak space and make hatch weathertight in accordance with 46 CFR 179.360.
Action required: 705 - Other - as specified
Due 9 June 2007
Resolved 24 May 2007
Resolution: Provided a 6 inch coaming on the forepeak hatch
Lifesaving › Lifejacket/PFD (General) › Lights
Issued 13 April 2007 Resolved
Provide lifejacket lights for all lifejackets as required by 46 CFR 180.75 prior to carrying passengers to the USS Oriskany artificial reef dive site
Action required: 705 - Other - as specified
Due 13 May 2007
Resolved 9 May 2007
Resolution: Provided lifejacket lights for all lifejackets.
Lifesaving › Lifejacket/PFD (Type I) › Condition
Issued 13 April 2007 Resolved
Provide 14 Coast Guard approved lifejackets as required by 46 CFR 180.71. The vessel is restricted to carrying 21 passengers until cleared by an attending Coast Guard Marine Inspector.
Due 13 May 2007
Resolved 9 May 2007
Resolution: Provided 14 Coast Guard approved lifejackets.
Lifesaving › Lifejacket/PFD (Type I) › Marking
Issued 13 April 2007 Resolved
Properly label lifejackets as required by 46 CFR 185.604
Action required: 705 - Other - as specified
Due 13 May 2007
Resolved 9 May 2007
Resolution: Properly labeled lifejackets.
Lifesaving › Lifejacket/PFD (Type I) › Storage
Issued 13 April 2007 Resolved
Proprerly stow all lifejackets as required by 46 CFR 180.78
Action required: 705 - Other - as specified
Due 13 May 2007
Resolved 9 May 2007
Resolution: Properly stowed all lifejackets.
Operations/Management › Equipment Service/Testing › EPIRB
Issued 16 August 2006 Resolved
Install updayed registration sticker.
Condition: Unknown
Due 23 August 2006
Resolved 18 August 2006
Engineering › Fuel Oil Storage/Transfer System › Piping
Issued 16 August 2006 Resolved
Install conductor to both fuel fill pipe flexible section.
Condition: Improper Installation
Due 23 August 2006
Resolved 18 August 2006
Engineering › Diesel Engine (propulsion-reduction gear) › Silencer (exhaust)
Issued 16 August 2006 Resolved
Seal exhaust leak on STBD engine.
Condition: Unknown
Due 23 August 2006
Resolved 18 August 2006
Fire Fighting › Portable Dry Chemical Fire Extinguisher
Issued 12 June 2003 Resolved
Provide servicing report for fire extinguishers and fixed fire fighting system. LEGACY COMPONENT DESC: Service
Due 12 July 2003
Resolved 11 July 2003
Navigation › Electronic Positioning
Issued 12 June 2003 Resolved
Replace expired hydrostatic release on EPIRB.
Due 12 July 2003
Resolved 11 July 2003
Operations/Management › Drills/Instruction › Fire
Issued 30 May 2002 Resolved
Conduct crew training and drills for fire and manoverboard situations and provide records of this training to the OCMI.
Condition: Improper/Lack of Maintenance
Due 7 June 2002
Resolved 6 June 2002
Operations/Management › Drills/Instruction › Fire
Issued 30 May 2002 Resolved
Demonstrate crew proficiency in fire and man-overboard drills in the presence of a CG marine inspector.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 30 June 2002
Resolved 27 June 2002
Resolution: Witnessed fire and man-overboard drills, sighted minimum acceptable performance, much room for improvement, counselled owner/master on providing additional training.
Communications › Radio Communications
Issued 30 May 2002 Resolved
Post emergency radio broadcast instructions. LEGACY COMPONENT DESC: Emergency Broadcast Instructions
Condition: Improper/Lack of Maintenance
Due 30 June 2002
Resolved 27 June 2002
Construction/Loadline › Markings › Vessel Name/Home Port
Issued 30 May 2002 Resolved
Mark vessel stern with vessel name and hailing port.
Condition: Improper/Lack of Maintenance
Due 7 June 2002
Resolved 5 June 2002
Lifesaving › Buoyant Apparatus
Issued 30 May 2002 Resolved
Attach 6-person life float to vessel with sea painter. LEGACY COMPONENT DESC: Sea Painter
Condition: Improper Installation
Action required: 701 - Prior to carriage of passengers/cargo
Due 7 June 2002
Resolved 5 June 2002
Lifesaving › Lifebuoys › Quantity
Issued 30 May 2002 Resolved
Replace deteriorated ring life buoy.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 7 June 2002
Resolved 5 June 2002
Engineering › Gasoline Engine (propulsion) › Ventilation
Issued 30 May 2002 Resolved
Replace deteriorated and missing ventialtion hose/ducting in engineroom and fuel tank space.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 6 June 2002
Resolved 5 June 2002
Electrical › Electrical Distribution System (service) › Wiring
Issued 30 May 2002 Resolved
Properly support electrical wiring in passenger spaces.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 7 June 2002
Resolved 5 June 2002
Engineering
Issued 22 May 2001 Resolved
Replace power ventilation couling on port motor blower prior to the compliance date.
Condition: Unknown
Due 30 May 2001
Resolved 12 June 2001
Lifesaving
Issued 22 May 2001 Resolved
Re-mount waterlights for the life-floats prior to the compliance date.
Condition: Unknown
Due 30 May 2001
Resolved 12 June 2001
Lifesaving
Issued 22 May 2001 Resolved
Repair damages to life-floats prior to the compliance date.
Condition: Unknown
Due 30 May 2001
Resolved 12 June 2001
Lifesaving
Issued 22 May 2001 Resolved
Provide two (2) paddles for each life-float prior to carrying passengers and prior to the compliance date.
Condition: Unknown
Due 30 May 2001
Resolved 12 June 2001
Electrical
Issued 4 June 2000 Resolved
REMOVE DEAD-END WIRING AND ELIMINATE TAPED SPLICES IN WIRING IN WAY OF PORTAND STARBOARD GUNWALES, PROVIDE ADEQUATE SUPPORTS FOR SAME BEFORE THE COMPLIANCE DATE.
Condition: Unknown
Due 16 June 2000
Resolved 14 June 2000
Construction/Loadline
Issued 4 June 2000 Resolved
PROVE OPERATION OF AUDIBLE SIGNAL FOR BILGE HIGH LEVEL ALARMS BEFORE THE COMPLIANCE DATE.
Condition: Unknown
Due 16 June 2000
Resolved 14 June 2000
Construction/Loadline
Issued 4 June 2000 Resolved
HULL BOTTOM PLATING THINNED AND WASTED, REQUIRING RENEWAL IWO PORT ENGINE MOUNTINGS, FOR AREA 3FT BY 7FT. CORRECTED DURING HULL EXAM.
Condition: Unknown
Due 4 June 2000
Resolved 4 June 2000
Fire Fighting
Issued 4 June 2000 Resolved
PROVIDE SERVICING REPORT FOR FIXED CO2 SYSTEM BEFORE THE COMPLIANCE DATE.
Condition: Unknown
Due 16 June 2000
Resolved 14 June 2000
Engineering
Issued 1 July 1999 Resolved
PRIOR TO CARRYING PASSENGERS, INSTALL ADEQUATE SUPPORTS FOR EXHAUST SYSTEMSON BOTH MAIN ENGINES, BEFORE THE COMPLIANCE DATE.
Condition: Unknown
Due 27 July 1999
Resolved 27 July 1999
Lifesaving
Issued 1 July 1999 Resolved
PROPERLY ATTACH FLOAT LIGHT TO LIFE BOUY AS PER 46 CFR 180.70(D) BEFORE THECOMPLIANCE DATE.
Condition: Unknown
Due 27 July 1999
Resolved 27 July 1999
Accommodation/Occupational Safety
Issued 1 July 1999 Resolved
PERMANENTLY REPAIR PORT AND STARBOARD HAND RAIL STANCHIONS BEFORE THE COMPLIANCE DATE.
Condition: Unknown
Due 27 July 1999
Resolved 27 July 1999
Engineering
Issued 1 July 1999 Resolved
PRIOR TO OPERATING, REPAIR AND ADJUST BOTH PROPULSION SHAFT DRIVE COUPLING FLANGES BEFORE THE COMPLIANCE DATE.
Condition: Unknown
Due 27 July 1999
Resolved 27 July 1999
Lifesaving
Issued 1 July 1999 Resolved
BEFORE CARRYING PASSENGERS, PROVIDE REPLACEMENTS FOR 4 ADULT SIZE PFD'S REJECTED DURING INSPECTION, BEFORE THE COMPLIANCE DATE.
Condition: Unknown
Due 27 July 1999
Resolved 27 July 1999
Fire Fighting
Issued 1 July 1999 Resolved
PRIOR TO CARRYING PASSENGERS, PROPERLY MOUNT FIXED CO2 CYLINDER, BEFORE THECOMPLIANCE DATE.
Condition: Unknown
Due 27 July 1999
Resolved 27 July 1999
Lifesaving
Issued 1 July 1999 Resolved
PRIOR TO CARRYING PASSENGERS, PROVIDE REPLACEMENTS FOR 3 MISSING HAND DISTRESS FLARES BEFORE THE COMPLIANCE DATE.
Condition: Unknown
Due 27 July 1999
Resolved 27 July 1999
Documentation
Issued 1 July 1999 Resolved
COI IMPROPERLY POSTED, AS TO OBSCURE 2ND PAGE, CORRECTED.
Condition: Unknown
Due 27 July 1999
Resolved 27 July 1999
Engineering
Issued 1 July 1999 Resolved
PRIOR TO OPERATING ENGINES, REPAIR, CLEAN AND AJUST FLAME ARRESTERS ON BOTHMAIN ENGINES, BEFORE THE COMPLIANCE DATE.
Condition: Unknown
Due 27 July 1999
Resolved 27 July 1999
Construction/Loadline
Issued 24 April 1986 Resolved
PLUG WELD TWO(2) BOLT HOLES THROUGH HULL IN ENGINE COMPARTMENT APPROX. 3" ON BOTH SIDES OF KEEL.
Condition: Unknown
Due 24 April 1986
Resolved 24 April 1986
Construction/Loadline
Issued 24 April 1986 Resolved
REPAIR OR REPLACE WRAP AROUND STRINGER IN CHAIN LOCKER CONNECTED TO UPPER DECK.
Condition: Unknown
Due 24 April 1986
Resolved 24 April 1986
Lifesaving
Issued 8 July 1985 Resolved
RPLACE EXPIRED FLARES.
Condition: Unknown
Due 8 July 1985
Resolved 8 July 1985
Lifesaving
Issued 8 July 1985 Resolved
PROVIDE AND PROPERLY ATTACH A FLOAT FREE LINK FOR EXISTING BUOYANT APPARATUS
Condition: Unknown
Due 8 July 1985
Resolved 8 July 1985

Casualty record · 1

28 May 2005Routine · role: Involved in a Marine Casualty · activity 2461462
Each line is an incident investigation the Coast Guard recorded with this hull among the vessels involved, with the date and the classification the Coast Guard gave it, and the bridge, lock or dam the investigation names where it names one. Involvement is not fault. The investigation narrative is not published. Source: IIR, through 2026.

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.