MAURY USCG vessel records Sign in
← All vessels

MAGIC SPIRIT

MAGIC SPIRIT is a 1983 passenger vessel (inspected). The Coast Guard has recorded 109 inspections since 1985, most recently in October 2006, along with 271 deficiencies — 5 with no resolution recorded —, 2 operational controls and 3 casualty investigations between 2002 and 2006.

Records from 1985 to 2006. Most recent: inspection, 27 October 2006.

Built
1983
Last inspected
27 October 2006
Documentation
Not in the documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

WBW8479
Flag
UNITED STATES
367149250 (licence lapsed)
Maury page id
psix-55026

Inspections, by type

…with no type recorded44
Years with a record 21 calendar years (1985–2006)
The 109 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

This record may be incomplete: the most recent inspection recorded for this vessel was 20 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 1977.

Documentation record

Tonnage as PSIX records it97 - Regulatory (Subpart C or D), Gross Ton
59 - Regulatory (Subpart C or D), Net Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.

Radio station licence

WDD4800MMSI 367149250 · expired · compulsorily equipped · granted 7 November 2006, cancelled 7 January 2017
WCY7178MMSI not assigned · expired · compulsorily equipped · granted 29 September 1998, cancelled 29 November 2008
FCC Universal Licensing System ship-station file of 6 September 2026, matched to this hull on its US Official Number. Status and dates are the file’s own. The licensee is not read from the file and is not shown. A lapsed licence’s MMSI is still the number the vessel transmitted under while it was valid.

Inspected as a tow unit · 1

The Coast Guard recorded this vessel and the following in the same inspection activity — normally a tug and the barges in its tow. A recreational or unclassed hull in the same activity is held and not published, so it does not appear here: these lists are a floor, not a complete manifest.

HULL #78 Passenger (Inspected) · MISLE 506397 · 25 May 2001 · activity 66065

Inspection history · 109

27 October 2006 COI Inspection · Examination of Repairs
Physical examination · Marine Safety Unit Coram · USCG Northeast District (CGD-NE) · Activity 2809164
25 October 2006 Type not recorded
No type recorded · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 2807683
14 September 2006 Type not recorded
No type recorded · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 2778488
6 September 2006 Type not recorded
No type recorded · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 2773319
6 September 2006 In-Service Inspection
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 2773330
28 July 2006 Administrative Inspection
Administrative · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 2727380
27 January 2006 Administrative Inspection
Administrative · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 2574717
15 November 2005 In-Service Inspection
Physical examination · Marine Safety Unit Lake Worth · USCG Southeast District (CGD-SE) · Activity 2547717
14 November 2005 Administrative Inspection
Administrative · Marine Safety Unit Lake Worth · USCG Southeast District (CGD-SE) · Activity 2534409
26 July 2005 Hull Examination · Internal Structural Exam · Deficiency Check
Physical examination · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 2439096
31 January 2005 Annual Inspection · MTSA Verification
Physical examination · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 2284174
14 January 2005 Administrative Inspection
Administrative · Detached Duty Office Fort Myers · USCG Southeast District (CGD-SE) · Activity 2274726
27 January 2004 Administrative Inspection
Administrative · Marine Safety Unit Lake Worth · USCG Southeast District (CGD-SE) · Activity 1993993
1 January 2004 Type not recorded
No type recorded · Marine Safety Unit Lake Worth · USCG Southeast District (CGD-SE) · Activity 2024099
30 December 2003 Security Plan Review - VSP
Administrative · Marine Safety Center (MSC) · Activity 1980308
10 November 2003 COI Inspection
Physical examination · Marine Safety Unit Lake Worth · USCG Southeast District (CGD-SE) · Activity 1943912
1 August 2003 Administrative Inspection
Administrative · Detached Duty Office Fort Myers · USCG Southeast District (CGD-SE) · Activity 1864000
12 July 2003 Internal Structural Exam · Hull Examination
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1840422
30 December 2002 Administrative Inspection · Deficiency Check
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1721702
21 October 2002 In-Service Inspection
Physical examination · MSO CHARLESTON · USCG Southeast District (CGD-SE) · Activity 1693563
15 October 2002 Type not recorded
No type recorded · MSO CHARLESTON · USCG Southeast District (CGD-SE) · Activity 1693664
20 August 2002 Examination of Repairs
Physical examination · MSO CHARLESTON · USCG Southeast District (CGD-SE) · Activity 1663819
15 June 2002 Type not recorded
No type recorded · MSO CHARLESTON · USCG Southeast District (CGD-SE) · Activity 1634267
2 May 2002 Deficiency Check
Physical examination · MSO CHARLESTON · USCG Southeast District (CGD-SE) · Activity 1611766
15 April 2002 COI Inspection
Physical examination · MSO CHARLESTON · USCG Southeast District (CGD-SE) · Activity 1495690
15 February 2002 In-Service Inspection
Physical examination · MSO CHARLESTON · USCG Southeast District (CGD-SE) · Activity 1482668
31 January 2002 Examination of Repairs
Physical examination · MSO CHARLESTON · USCG Southeast District (CGD-SE) · Activity 1483706
23 January 2002 In-Service Inspection
Physical examination · MSO CHARLESTON · USCG Southeast District (CGD-SE) · Activity 1481050
24 October 2001 Deficiency Check
Physical examination · MSO CHARLESTON · USCG Southeast District (CGD-SE) · Activity 1075733
21 October 2001 Type not recorded
No type recorded · MSO CHARLESTON · USCG Southeast District (CGD-SE) · Activity 1624725
9 October 2001 Deficiency Check
Physical examination · MSO CHARLESTON · USCG Southeast District (CGD-SE) · Activity 1075336
30 August 2001 Deficiency Check
Physical examination · MSO CHARLESTON · USCG Southeast District (CGD-SE) · Activity 1071797
24 August 2001 Type not recorded
No type recorded · MSO CHARLESTON · USCG Southeast District (CGD-SE) · Activity 134250
23 July 2001 Type not recorded
No type recorded · MSO CHARLESTON · USCG Southeast District (CGD-SE) · Activity 82148
20 July 2001 Deficiency Check
Physical examination · MSO CHARLESTON · USCG Southeast District (CGD-SE) · Activity 1070929
4 June 2001 Type not recorded
No type recorded · MSO CHARLESTON · USCG Southeast District (CGD-SE) · Activity 1066260
2 June 2001 Type not recorded
No type recorded · MSO CHARLESTON · USCG Southeast District (CGD-SE) · Activity 158726
29 May 2001 Deficiency Check
Physical examination · MSO CHARLESTON · USCG Southeast District (CGD-SE) · Activity 1066229
25 May 2001 Type not recorded
No type recorded · MSO CHARLESTON · USCG Southeast District (CGD-SE) · Activity 66065
15 May 2001 Re-Inspection
Physical examination · MSO CHARLESTON · USCG Southeast District (CGD-SE) · Activity 1418904
30 April 2001 Type not recorded
No type recorded · MSO CHARLESTON · USCG Southeast District (CGD-SE) · Activity 1064047
13 April 2001 Type not recorded
No type recorded · MSO CHARLESTON · USCG Southeast District (CGD-SE) · Activity 1444510
27 March 2001 Deficiency Check
Physical examination · MSO CHARLESTON · USCG Southeast District (CGD-SE) · Activity 1060918
23 March 2001 Hull Examination
Physical examination · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 1403303
27 January 2001 Type not recorded
No type recorded · MSO CHARLESTON · USCG Southeast District (CGD-SE) · Activity 13360
12 September 2000 Deficiency Check
Physical examination · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 1463612
29 August 2000 Damage Survey
Physical examination · MSO CHARLESTON · USCG Southeast District (CGD-SE) · Activity 822461
26 August 2000 Type not recorded
No type recorded · MSO CHARLESTON · USCG Southeast District (CGD-SE) · Activity 120532
17 August 2000 Type not recorded
No type recorded · MSO CHARLESTON · USCG Southeast District (CGD-SE) · Activity 159032
16 August 2000 Type not recorded
No type recorded · MSO CHARLESTON · USCG Southeast District (CGD-SE) · Activity 1410386
7 August 2000 Type not recorded
No type recorded · MSO CHARLESTON · USCG Southeast District (CGD-SE) · Activity 145164
8 May 2000 Re-Inspection
Physical examination · MSO CHARLESTON · USCG Southeast District (CGD-SE) · Activity 1421882
8 February 2000 Administrative
Administrative · MSO CHARLESTON · USCG Southeast District (CGD-SE) · Activity 1045704
20 January 2000 Type not recorded
No type recorded · MSO CHARLESTON · USCG Southeast District (CGD-SE) · Activity 1048041
5 November 1999 Type not recorded
No type recorded · MSO CHARLESTON · USCG Southeast District (CGD-SE) · Activity 805143
13 May 1999 COI Inspection
Physical examination · MSO CHARLESTON · USCG Southeast District (CGD-SE) · Activity 1415225
15 April 1999 Type not recorded
No type recorded · MSO CHARLESTON · USCG Southeast District (CGD-SE) · Activity 81449
15 April 1999 Damage Survey
Physical examination · MSO CHARLESTON · USCG Southeast District (CGD-SE) · Activity 1114423
14 April 1999 Type not recorded
No type recorded · MSO CHARLESTON · USCG Southeast District (CGD-SE) · Activity 3383
5 April 1999 Deadweight Survey
Physical examination · MSO CHARLESTON · USCG Southeast District (CGD-SE) · Activity 778371
17 March 1999 Type not recorded
No type recorded · MSO CHARLESTON · USCG Southeast District (CGD-SE) · Activity 1114422
2 February 1999 Hull Examination
Physical examination · MSO SAVANNAH · USCG Southeast District (CGD-SE) · Activity 1375631
21 January 1999 Deficiency Check
Physical examination · MSO CHARLESTON · USCG Southeast District (CGD-SE) · Activity 1365047
15 May 1998 Re-Inspection
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1126371
25 February 1998 Type not recorded
No type recorded · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1434685
16 July 1997 Re-Inspection · MARPOL Annex V Examination
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1115462
27 June 1997 Hull Examination
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1414827
9 October 1996 MARPOL Annex V Examination
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 840956
9 July 1996 Type not recorded
No type recorded · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 697300
13 May 1996 Deficiency Check · COI Inspection
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1464637
11 April 1996 Type not recorded
No type recorded · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 16406
1 February 1996 Type not recorded
No type recorded · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 107856
23 May 1995 COI Inspection
Physical examination · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 1360116
10 May 1995 Hull Examination
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 871139
20 October 1994 Type not recorded
No type recorded · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1172777
29 August 1994 Type not recorded
No type recorded · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1175743
29 August 1994 Type not recorded
No type recorded · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1176661
11 August 1994 Type not recorded
No type recorded · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 693567
22 July 1994 Type not recorded
No type recorded · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 155178
12 July 1994 Deficiency Check
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 863581
25 May 1994 COI Inspection
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1016523
1 May 1994 Type not recorded
No type recorded · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 4771
8 November 1993 Type not recorded
No type recorded · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1154770
11 August 1993 Deficiency Check
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 846312
6 August 1993 Deficiency Check
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 844348
7 July 1993 Type not recorded
No type recorded · MSO Mobile · USCG Heartland District (CGD-H) · Activity 844045
25 June 1993 COI Inspection
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1155923
16 June 1993 Hull Examination
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 845543
26 June 1992 Hull Examination
Physical examination · MSO DETROIT · USCG Great Lakes District (CGD-GL) · Activity 1154879
16 May 1990 Deficiency Check
Physical examination · MSO CHICAGO · USCG Great Lakes District (CGD-GL) · Activity 1243339
11 April 1990 Deficiency Check
Physical examination · MSO CHICAGO · USCG Great Lakes District (CGD-GL) · Activity 911212
5 April 1990 COI Inspection
Physical examination · MSO CHICAGO · USCG Great Lakes District (CGD-GL) · Activity 1235013
12 October 1989 Administrative
Administrative · MSO CHICAGO · USCG Great Lakes District (CGD-GL) · Activity 1341029
18 April 1989 COI Inspection
Physical examination · MSO CHICAGO · USCG Great Lakes District (CGD-GL) · Activity 889390
14 July 1988 Administrative
Administrative · MSO CHICAGO · USCG Great Lakes District (CGD-GL) · Activity 898665
26 April 1988 COI Inspection
Physical examination · MSO CHICAGO · USCG Great Lakes District (CGD-GL) · Activity 889546
18 March 1988 Type not recorded
No type recorded · MSO CHICAGO · USCG Great Lakes District (CGD-GL) · Activity 1342352
30 October 1987 Type not recorded
No type recorded · MSO CHICAGO · USCG Great Lakes District (CGD-GL) · Activity 1028713
8 May 1987 Type not recorded
No type recorded · MSO CHICAGO · USCG Great Lakes District (CGD-GL) · Activity 1332482
27 April 1987 COI Inspection
Physical examination · MSO CHICAGO · USCG Great Lakes District (CGD-GL) · Activity 1021054
16 March 1987 Type not recorded
No type recorded · MSO CHICAGO · USCG Great Lakes District (CGD-GL) · Activity 1323254
24 February 1987 Type not recorded
No type recorded · MSO CHICAGO · USCG Great Lakes District (CGD-GL) · Activity 1003845
31 October 1986 Credit Drydock
Administrative · MSO CHICAGO · USCG Great Lakes District (CGD-GL) · Activity 1012460
2 May 1986 Deficiency Check
Physical examination · MSO CHICAGO · USCG Great Lakes District (CGD-GL) · Activity 1297120
30 April 1986 COI Inspection
Physical examination · MSO CHICAGO · USCG Great Lakes District (CGD-GL) · Activity 1301076
24 July 1985 Type not recorded
No type recorded · MSO CHICAGO · USCG Great Lakes District (CGD-GL) · Activity 983266
30 May 1985 Type not recorded
No type recorded · MSO CHICAGO · USCG Great Lakes District (CGD-GL) · Activity 1289454
1 May 1985 Deficiency Check
Physical examination · MSO CHICAGO · USCG Great Lakes District (CGD-GL) · Activity 987562
3 April 1985 Type not recorded
No type recorded · MIO ST. IGNACE · USCG Great Lakes District (CGD-GL) · Activity 1286044

Deficiency record · 271

Electrical › Electrical Distribution System (service) › Junction Box
Issued 27 October 2006 Resolved
Reroute wiring at light fixture located at the stbd aft end of the engine room so that the fixture is not utilized as a junction box.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 30 November 2006
Resolved 13 November 2006
Resolution: Corrected
Accommodation/Occupational Safety › Ventilation › General
Issued 27 October 2006 Resolved
Clean oily debris and dirt from exhaust vents for engine room.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 30 November 2006
Resolved 20 November 2006
Resolution: Cleaned.
Electrical › Electric Supply System (service) › Battery Installation
Issued 27 October 2006 Resolved
Repair battery box in engine room.
Condition: Unknown
Due 30 November 2006
Resolved 20 November 2006
Resolution: Corrected.
Electrical › Electrical Distribution System (service) › Wiring
Issued 27 October 2006 Resolved
Remove electric conductor in engine room from stuffing tube designated for air pressure line and properly fit it thru a wiring stuffing tube.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 30 November 2006
Resolved 13 November 2006
Resolution: Corrected
Accommodation/Occupational Safety › Occupational Safety › Tripping/Falling Hazard
Issued 27 October 2006 Resolved
Repair damaged and worn deck plates in the engine room and insure they are secured in place.
Condition: Improper/Lack of Maintenance
Due 30 November 2006
Resolved 20 November 2006
Resolution: Corrected.
Electrical › Electrical Distribution System (service) › Switchboard
Issued 27 October 2006 Resolved
Prove ability to parallel ship service generators. Syncroscope not operating.
Condition: Unknown
Action required: 705 - Other - as specified
Due 30 November 2006
Resolved 20 November 2006
Resolution: Corrected. Wiring error.
Electrical › Electric Supply System (service) › Battery Installation
Issued 27 October 2006 Resolved
Repair battery gauges in the engine room.
Condition: Unknown
Due 30 November 2006
Resolved 20 November 2006
Resolution: Corrected.
Electrical › Electrical Distribution System (service) › Switchboard
Issued 27 October 2006 Resolved
Secure grab rail on main switchboard.
Condition: Improper/Lack of Maintenance
Due 30 November 2006
Resolved 13 November 2006
Resolution: Corrected
Electrical › Electrical Distribution System (service) › Panelboard
Issued 27 October 2006 Resolved
Close unused knock out holes with proper fittings accepted by NEC. (Multiple panels involved.)
Condition: Improper Installation
Due 30 November 2006
Resolved 13 November 2006
Resolution: Corrected
Electrical › Electrical Distribution System (service) › Wiring
Issued 27 October 2006 Resolved
Install proper size strain relief on conductors attached to engine room distribution panel.
Condition: Improper/Lack of Maintenance
Due 30 November 2006
Resolved 13 November 2006
Resolution: Corrected.
Electrical › Electrical Distribution System (service) › Switch
Issued 27 October 2006 Resolved
Install a proper sized NEC accepted hole cover in the open knockout located on the E/R exhaust fan motor controller.
Condition: Improper Installation
Due 30 November 2006
Resolved 13 November 2006
Resolution: Corrected
Electrical › Electric Generation Source (service) › Metallic Enclosure/Frame
Issued 27 October 2006 Resolved
Provide replacement of missing screws used to secure the conductor junction box cover plates for SSGens nos. 2 & 3.
Condition: Improper/Lack of Maintenance
Due 30 November 2006
Resolved 13 November 2006
Resolution: Corrected
Engineering › Diesel Engine (propulsion-reduction gear) › Gear/Clutch Starter (electric)
Issued 27 October 2006 Resolved
Clean wiring connections to starter #2 MDE.
Condition: Improper/Lack of Maintenance
Due 30 November 2006
Resolved 13 November 2006
Resolution: Completed.
Electrical › Lighting (service) › Lighting Fixture
Issued 27 October 2006 Resolved
Provide replacements for all missing lighting fixture covers in E/R.
Condition: Improper/Lack of Maintenance
Due 30 November 2006
Resolved 20 November 2006
Resolution: Corrected.
Electrical › Electrical Distribution System (service) › Wiring
Issued 27 October 2006 Resolved
Remove dead ended wiring next to the outboard side of the #2 MDE.
Condition: Unknown
Due 30 November 2006
Resolved 13 November 2006
Resolution: Corrected
Operations/Management › Bilge/Bilge System Management › Control of Oil Mixtures
Issued 27 October 2006 Resolved
Clean debris and oily waste from E/R bilges.
Condition: Improper/Lack of Maintenance
Due 30 November 2006
Resolved 13 November 2006
Resolution: Corrected
Engineering › Bilge Water Management System › Manifold
Issued 27 October 2006 Resolved
Provide labels for bilge manifold valves.
Condition: Damaged By Earlier Event
Due 30 November 2006
Resolved 13 November 2006
Resolution: Corrected
Electrical › Electric Generation Source (service) › Metallic Enclosure/Frame
Issued 27 October 2006 Resolved
Provide the cover for the junction box IWO the #1 SSG.
Condition: Improper/Lack of Maintenance
Due 30 November 2006
Resolved 13 November 2006
Resolution: Corrected
Fire Fighting › Means of Escape › Blocked
Issued 27 October 2006 Resolved
Prove operational condition of emergency escape from E/R.
Condition: Improper/Lack of Maintenance
Due 13 November 2006
Resolved 13 November 2006
Resolution: Corrected
Electrical › Electrical Distribution System (service) › Junction Box
Issued 27 October 2006 Resolved
Secure port forward junction box in galley to the bhd.
Condition: Improper/Lack of Maintenance
Due 30 November 2006
Resolved 13 November 2006
Resolution: Corrected
Engineering › Bilge Water Management System › Not Operational
Issued 27 October 2006 Resolved
Prove capability to pump bilge water from void space below galley.
Condition: Improper/Lack of Maintenance
Due 30 November 2006
Resolved 20 November 2006
Resolution: Corrected.
Electrical › Electrical Distribution System (service) › Metallic Enclosure/Frame
Issued 27 October 2006 Resolved
Replace missing electrical controller covers for all hot water heaters in galley space.
Condition: Improper/Lack of Maintenance
Due 30 November 2006
Resolved 13 November 2006
Resolution: Corrected
Accommodation/Occupational Safety › Other Accommodation Spaces › Recreation Space
Issued 27 October 2006 Resolved
Repair broken windows on second deck ladderway.
Condition: Damaged By Earlier Event
Due 30 November 2006
Resolved 13 November 2006
Resolution: Corrected
Electrical › Lighting (service) › Lighting Fixture
Issued 27 October 2006 Resolved
Replace missing glass globes for lighting fixtures in E/R.
Condition: Improper Installation
Due 30 November 2006
Resolved 13 November 2006
Resolution: Corrected
Engineering › Compressed Air System (control) › Compressor
Issued 27 October 2006 Resolved
Replace Fx glass on pressure gauge.
Condition: Damaged By Earlier Event
Due 30 November 2006
Resolved 13 November 2006
Resolution: Corrected
Fire Fighting › Fixed CO2 Fire Extinguishing System › Operating Instructions
Issued 27 October 2006 Resolved
Properly label fire suppression instruction placard on main deck.
Condition: Unknown
Due 30 November 2006
Resolved 13 November 2006
Resolution: Corrected
Electrical › Electrical Distribution System (service) › Junction Box
Issued 27 October 2006 Resolved
Properly secure junction box on main deck stbd side fwd, IWO slot machines, to bhd.
Condition: Improper Installation
Due 30 November 2006
Resolved 13 November 2006
Resolution: Corrected.
Electrical › Lighting (service) › Lighting Fixture
Issued 27 October 2006 Resolved
Replace broken glass globe on light in steering compartment.
Condition: Damaged By Earlier Event
Due 28 November 2006
Resolved 8 November 2006
Resolution: Corrected.
Communications › Alarms/Indicators › Lube Oil Low Pressure Alarm
Issued 27 October 2006 Resolved
Prove operation of PMDE oil pressure gauge on bridge engine monitor panel.
Condition: Improper Installation
Due 28 November 2006
Resolved 20 November 2006
Resolution: Corrected.
Engineering › Electric Propulsion System › Junction
Issued 27 October 2006 Resolved
Renew all worn ball and socket fittings on push-pull cables for mechanical control of clutches and engine throtles.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 28 November 2006
Resolved 20 November 2006
Resolution: Corrected.
Documentation › Certificates/Documents › Cargo Ship Safety Radio Certificate
Issued 27 October 2006 Resolved
Provide a current FCC radiotelephone safety cert.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 28 November 2006
Resolved 13 November 2006
Resolution: Corrected.
Documentation › Certificates/Documents › Certificate of Documentation (CG-1270)
Issued 27 October 2006 No resolution recorded
Maintain original COD aboard upon arrival from NVDC.
Condition: Unknown
Action required: 705 - Other - as specified
Documentation › Certificates/Documents › Stability Letter
Issued 27 October 2006 Resolved
Post Stability letter in pilot house so that all pages are visible.
Condition: Unknown
Due 4 December 2006
Resolved 20 November 2006
Resolution: Corrected.
Operations/Management › Passenger Operations › Safety Orientation
Issued 27 October 2006 Resolved
Update passenger safety orientation to reflect new name of vessel and circumstances of current operations.
Condition: Design Flaw
Due 4 December 2006
Resolved 13 November 2006
Resolution: Corrected.
Electrical › Electrical Distribution System (service) › Panelboard
Issued 27 October 2006 Resolved
Clearly label all galley electric panels.
Condition: Improper/Lack of Maintenance
Due 30 November 2006
Resolved 20 November 2006
Resolution: Corrected.
Fire Fighting › Ventilation Systems › Exhaust Ducts (Galley Ranges)
Issued 27 October 2006 Resolved
Clearly mark galley vent shut down.
Condition: Improper/Lack of Maintenance
Due 30 November 2006
Resolved 13 November 2006
Resolution: Corrected.
Accommodation/Occupational Safety › Washroom/Toilet › Toilet
Issued 27 October 2006 Resolved
Repair leak in water supply to toilet in men’s head below main deck.
Condition: Improper/Lack of Maintenance
Due 30 November 2006
Resolved 20 November 2006
Resolution: Corrected.
Fire Fighting › Fixed Gas Fire Extinguishing System › Operating Controls
Issued 27 October 2006 Resolved
Correct operating instructions for galley range fixed fire extinguishing system. Include location of controls and vent shut-downs.
Condition: Improper/Lack of Maintenance
Due 30 November 2006
Resolved 13 November 2006
Resolution: Corrected.
Electrical › Lighting (emergency) › Lighting Fixture
Issued 27 October 2006 Resolved
Prove operation of battery powered emergency light on main deck at the fwd bhd of the passenger accommodations.
Condition: Design Flaw
Due 30 November 2006
Resolved 20 November 2006
Resolution: Corrected. (note: This lamp is in addition to the build in "E" lighting system and is not connected to the emergency power bus. If the vessel is laid up for more than 24 hours as a cold ship the battery will run down.)
Accommodation/Occupational Safety › Medical/First Aid › Medicine Chest
Issued 27 October 2006 Resolved
provide a proper and complete first aid kit IAW regulations.
Condition: Improper/Lack of Maintenance
Due 30 November 2006
Resolved 13 November 2006
Resolution: Corrected.
Engineering › Lubricating Oil Service System › Gauge
Issued 27 October 2006 Resolved
Bridge PMDE oil pressure gauge is inoperable.
Condition: Unknown
Due 30 November 2006
Resolved 20 November 2006
Resolution: Repaired crossed wiring.
Electrical › Electrical Distribution System (service) › Metallic Enclosure/Frame
Issued 27 October 2006 Resolved
Repair distribution panel covers on second deck port side fwd.
Condition: Improper/Lack of Maintenance
Due 30 November 2006
Resolved 13 November 2006
Resolution: Corrected.
Accommodation/Occupational Safety › Occupational Safety › Deck Rail
Issued 27 October 2006 Resolved
Repair wasted deck rails.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 30 November 2006
Resolved 22 November 2006
Resolution: Sufficient replacement of wasted sections completed to permit the vessel to return to safe operation. All rails IWO passenger spaces found satisfactory but due to past wastage/maintenance history should be reexamined at next drydocking. Inspection note
Electrical › Lighting (service) › Lighting Feeder
Issued 27 October 2006 Resolved
Remove dead ended out of service conductor IWO the life raft stations on the third deck.
Condition: Improper Installation
Due 30 November 2006
Resolved 13 November 2006
Resolution: Corrected.
Accommodation/Occupational Safety › Ventilation › General
Issued 27 October 2006 Resolved
Remove out of service vent located port & stbd sides aft on main deck leading to vessel exterior from overhead of passenger space.
Condition: Improper Installation
Due 30 November 2006
Resolved 20 November 2006
Resolution: Corrected.
Stability › Weathertight Integrity › General
Issued 27 October 2006 No resolution recorded
Crop and Renew all wasted window frames at next drydock.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Accommodation/Occupational Safety › Occupational Safety › Tripping/Falling Hazard
Issued 27 October 2006 No resolution recorded
Crop and Renew wasted ladder way treads on aft ladder between main and second deck.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Lifesaving › Lifejacket/PFD (Type I) › Retroreflective Material
Issued 27 October 2006 Resolved
Replace three adult type I PFDs.
Condition: Improper/Lack of Maintenance
Due 30 November 2006
Resolved 20 November 2006
Resolution: Corrected.
Lifesaving › Lifejacket/PFD (Type I) › Retroreflective Material
Issued 27 October 2006 Resolved
Replace retroreflective material on five adult PFDs.
Condition: Improper/Lack of Maintenance
Due 30 November 2006
Resolved 20 November 2006
Resolution: Replaced.
Electrical › Electrical Distribution System (service) › Wiring
Issued 27 October 2006 Resolved
Tie up all loose wiring, replace missing cover plates and in general clean up wiring installation for security system in surveillance room.
Condition: Improper Installation
Due 30 November 2006
Resolved 20 November 2006
Resolution: Corrected.
Engineering › Electric Propulsion System › Circuit Breaker (overload/over current protection)
Issued 27 October 2006 Resolved
Prove operation of PMDE shut-down from pilot house.
Condition: Improper/Lack of Maintenance
Due 30 November 2006
Resolved 20 November 2006
Resolution: Corrected.
Construction/Loadline › Structures › Ventilators
Issued 27 October 2006 No resolution recorded
Repair port and starboard vent check valves as well as vent end housings for MSD tanks at next drydocking. (note: flame screens and temporary repairs are in place.)
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Engineering › Shafting/Propeller Arrangements › Propeller (fixed pitch)
Issued 14 September 2006 No resolution recorded
Provide new port propeller and rudder.
Condition: Damaged By Earlier Event
Action required: 17 - Rectify deficiencies prior to departure
Resolution: Vessel had new port rudder constructed and new port propeller and rudder were installed. Sea trials were conducted 19 Oct 2006 w/ sat results.
Accommodation/Occupational Safety › Occupational Safety › Deck Rail
Issued 14 September 2006 Resolved
Railing on aft stairwell 3rd deck rust through and loose. To be completed to the sat. of attending M.I. in Freeport, NY.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 20 November 2006
Resolved 20 November 2006
Lifesaving › Lifebuoys › Buoyant Lifeline
Issued 14 September 2006 Resolved
Provide lifelines for wheelhouse (port) and stern life ring buoys.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Resolved 20 November 2006
Lifesaving › Lifejacket/PFD (Type I) › Retroreflective Material
Issued 14 September 2006 Resolved
Inspect and replace retro-reflectrive tape on life jackets as needed.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Resolved 20 November 2006
Lifesaving › Inflatable Buoyant Apparatus › Quantity
Issued 14 September 2006 Resolved
Vessel was missing one IBA due to servicing issues to meet the lifesaving requirements.
Condition: Unknown
Action required: 705 - Other - as specified
Resolved 20 November 2006
Resolution: Vessel''s total passengers reduced to NMT 150 by request of the operator until the third IBA is provided.
Electrical › Electrical Distribution System (service) › Wiring
Issued 14 September 2006 Resolved
Ensure all electrical connection are of suitable type (barrel or 'butt' type) on all wiring circuits.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Resolved 6 November 2006
Resolution: Corrected.
Operations/Management › Drills/Instruction › Activating General Alarm
Issued 14 September 2006 Resolved
Prove proper operation of General Alarm/Public Address system.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Resolved 20 November 2006
Resolution: No gen alarm required. Pa tested sat.
Construction/Loadline › Hull › Side Shell
Issued 14 September 2006 Resolved
Provide Dive Survey to determine the condition of the hull after grounding.
Condition: Damaged By Earlier Event
Action required: 17 - Rectify deficiencies prior to departure
Resolved 19 October 2006
Resolution: Diver completed hull survey. All SAT.
Operations/Management › Navigation Safety › Navigation Underway, General
Issued 14 September 2006 Resolved
Prove proper operation of vsl's propulsion and steering system by means of a satisfactory sea trial.
Condition: Damaged By Earlier Event
Action required: 17 - Rectify deficiencies prior to departure
Resolved 19 October 2006
Resolution: Satisfactory sea trial was conducted with proper operation of machinery and steering witnessed.
Personnel › Manning/Qualifications › Minimum Safe Manning
Issued 14 September 2006 Resolved
Provide suitable manning proposal for remaining transit from Little River, SC to Freeport, NY.
Condition: Unknown
Action required: 17 - Rectify deficiencies prior to departure
Resolved 19 October 2006
Resolution: Manning proposal was submitted with 2 Licensed captains, 2 persons to act a deckhands, and one individual familiar with machinery on board.
Construction/Loadline › Penetrations › Weld
Issued 14 September 2006 Resolved
Properly repair aft main deck plates where rusted through or cut open.
Condition: Damaged By Earlier Event
Action required: 17 - Rectify deficiencies prior to departure
Resolved 19 October 2006
Resolution: Deck plating was cropped and renewed and rewelded where necessary.
Operations/Management › Pollution › Retention of Oily Mixture
Issued 14 September 2006 Resolved
Remove excessive oil in bilges in vessel's engine room
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Resolved 20 November 2006
Resolution: Corrected.
Lifesaving › Rescue Boat › Carriage Requirement
Issued 15 November 2005 Resolved
Provide rescue boat.
Condition: Placed in Improper Service
Due 1 December 2005
Resolved 20 November 2006
Resolution: Not required by virtue of successful MOB drills demonstrating the ability to retrieve a MOB via a rescue platform. 46 CFR 117.210(a)
Accommodation/Occupational Safety › Medical/First Aid › Medicine Chest
Issued 15 November 2005 Resolved
Provide approved first aid kit.
Condition: Placed in Improper Service
Due 1 December 2005
Resolved 20 November 2006
Electrical › Electrical Distribution System (service) › Outlet Box
Issued 15 November 2005 Resolved
Properly secure 110v outlet box and conduit above bar on upper deck.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 1 December 2005
Resolved 6 November 2006
Resolution: Corrected.
Lifesaving › Inflatable Buoyant Apparatus › Stowage
Issued 15 November 2005 Resolved
Correctly install sea painter on IBA.
Condition: Placed in Improper Service
Action required: 705 - Other - as specified
Due 16 November 2005
Resolved 20 November 2006
Electrical › Electrical Distribution System (service) › Metallic Enclosure/Frame
Issued 15 November 2005 Resolved
Renew A/C controller/circuit box located on 2nd deck aft port side.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 1 December 2005
Resolved 6 November 2006
Resolution: Corrected.
Electrical › Electrical Distribution System (service) › Outlet Box
Issued 15 November 2005 Resolved
repair outlet box located on maindeck starboard side, stainless column.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 1 December 2005
Resolved 6 November 2006
Resolution: Corrected.
Accommodation/Occupational Safety › Occupational Safety › Hand Grab
Issued 15 November 2005 Resolved
Install second hand rail in stairway between second and third decks aft on open deck.
Condition: Unknown
Action required: 705 - Other - as specified
Due 29 December 2005
Resolved 20 November 2006
Fire Fighting › Miscellaneous Items › A Class Division Penetrations
Issued 15 November 2005 Resolved
Provide means of securing ventilation to engineroom.
Condition: Unknown
Action required: 705 - Other - as specified
Due 29 December 2005
Resolved 20 November 2006
Resolution: Corrected.
Engineering › Diesel Engine (propulsion-electric) › Piping (exhaust)
Issued 15 November 2005 Resolved
Repair port main engine exhaust leak at aft bulkhead.
Condition: Unknown
Action required: 705 - Other - as specified
Due 29 December 2005
Resolved 6 November 2006
Resolution: Corrected.
Accommodation/Occupational Safety › Occupational Safety › Guards for Exposed Hazards
Issued 15 November 2005 Resolved
Install protective cover on port engine, outboard exhaust manifold.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 29 December 2005
Resolved 15 November 2005
Pollution Prevention/Response › Prevention Equipment › Drains/Scuppers (means of closure)
Issued 15 November 2005 Resolved
Install valve on urinal drain line leading overboard.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 29 December 2005
Resolved 30 December 2005
Fire Fighting › Structural Fire Protection - General › Structural Bulkhead Construction
Issued 15 November 2005 Resolved
Provide copy of approved structural fire protection plans reflecting modifications made in 1999. Provide approved plans showing windows on second deck in an A-0 boundary meet the boundary requirement.
Condition: Placed in Improper Service
Action required: 705 - Other - as specified
Due 29 December 2005
Resolved 6 November 2006
Resolution: Corrected.
Documentation › Safety/Response Plans/Programs › General Arrangement Plans
Issued 15 November 2005 Resolved
Provide approved plans for modifications made to vessel on main deck stairwell in 1993. Vessel has had modifications made without prior approval.
Condition: Unknown
Action required: 705 - Other - as specified
Due 29 December 2005
Resolved 6 November 2006
Documentation › Safety/Response Plans/Programs › General Arrangement Plans
Issued 15 November 2005 Resolved
Provide approved plans for ventilation systems to all below deck spaces that pass through accomodation spaces - Galley and engineroom.
Condition: Unknown
Action required: 705 - Other - as specified
Due 29 December 2005
Resolved 6 November 2006
Construction/Loadline › Hull › Stiffener
Issued 26 July 2005 Resolved
Conduct gauging in forepeak tank and provide report to CG marine inspector. Numerous angles and support member are wasted.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 28 July 2005
Resolved 1 August 2005
Resolution: Received Gauging report. Several angles and plating were wastage beyond the required limits. Damage steel crop and renewed to the satisfaction of the attending Marine Inspector.
Electrical › Electric Supply System (service) › Cable
Issued 26 July 2005 Resolved
Secure loose wiring in bow thruster space.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 26 August 2005
Resolved 29 July 2005
Resolution: Electrical cabling was properly secure.
Electrical › Electric Supply System (service) › Cable
Issued 26 July 2005 Resolved
Remove wire nuts from electrical conductors in bow thruster space.
Condition: Unknown
Action required: 705 - Other - as specified
Due 26 August 2005
Resolved 29 July 2005
Resolution: Wire nuts were removed and the electrical conductors properly installed.
Electrical › Electric Supply System (service) › Cable
Issued 26 July 2005 Resolved
Properly seal electrical thru hull bulkhead fittings and remove all dead end cables in midship void space.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 26 August 2005
Resolved 1 August 2005
Resolution: Bulkhead thru hull fitting were properly sealed and dead end cables removed.
Construction/Loadline › Structures › Transverse Bulkhead
Issued 26 July 2005 Resolved
Crop and renew vertical angle under potable water tank and repair fractured weld at frame 11 in the females head void space.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 28 July 2005
Resolved 29 July 2005
Resolution: Vertical angle replaced and bulkhead 11 was cropped and renewed.
Electrical › Electric Supply System (service) › Cable
Issued 26 July 2005 Resolved
Properly seal electrical thru hull bulkhead fittings.
Condition: Unknown
Action required: 705 - Other - as specified
Due 28 July 2005
Resolved 1 August 2005
Resolution: Thru hull fittings properly sealed.
Accommodation/Occupational Safety › Occupational Safety › Rubbish/Waste Materials
Issued 26 July 2005 Resolved
Ladies and Mens Head Voids: Remove all hazardous chemicals and trash from the spaces.
Condition: Unknown
Action required: 705 - Other - as specified
Due 26 August 2005
Resolved 29 July 2005
Resolution: Hazradous chemicals and trash was removed.
Electrical › Electrical Distribution System (service) › Distribution Panel Bus
Issued 26 July 2005 Resolved
Properly cover holes in the electrical switchboard.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 26 August 2005
Resolved 29 July 2005
Resolution: Holes were properly sealed.
Operations/Management › Bilge/Bilge System Management › Control of Oil Mixtures
Issued 26 July 2005 Resolved
Remove all oily hazards from engine room bilges.
Condition: Unknown
Action required: 705 - Other - as specified
Due 28 July 2005
Resolved 29 July 2005
Resolution: Hazards removed and bilges were cleaned to the satisfaction of the attending Marine Inspector.
Electrical › Electric Supply System (service) › Cable
Issued 26 July 2005 Resolved
Remove wire nuts from the lazarette bilge float.
Condition: Unknown
Action required: 705 - Other - as specified
Due 26 August 2005
Resolved 1 August 2005
Resolution: CORRECTED
Engineering › Diesel Engine (auxiliary) › Piping (exhaust)
Issued 26 July 2005 Resolved
Crop and renew port side exhaust cover in way of aft overhead (lazarette). Exhaust cover and coaming is completely wasted.
Condition: Unknown
Action required: 705 - Other - as specified
Due 28 July 2005
Resolved 1 August 2005
Resolution: Cover and coaming was renewed.
Operations/Management › Bilge/Bilge System Management › Control of Excess Water
Issued 26 July 2005 Resolved
Clean lazarette bilges for reinspection.
Condition: Unknown
Action required: 705 - Other - as specified
Due 28 July 2005
Resolved 1 August 2005
Resolution: Conducted a satisfactory inspection of bilges.
Engineering › Thrusters › Tunnel
Issued 26 July 2005 Resolved
Crop and renew bow thruster grating. (port side).
Condition: Unknown
Action required: 705 - Other - as specified
Due 28 July 2005
Resolved 1 August 2005
Resolution: Grating was properly welded.
Construction/Loadline › Hull › Weld
Issued 26 July 2005 Resolved
Port side engine room sea chest welds are fractured.
Condition: Unknown
Action required: 705 - Other - as specified
Due 28 July 2005
Resolved 1 August 2005
Resolution: Welds were grind down and properly welded.
Electrical › Electric Supply System (service) › Cable
Issued 26 July 2005 Resolved
Properly seal all electrical thru hull bulkhead fittings throughout the vessel.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 1 September 2005
Resolved 6 November 2006
Resolution: Corrected.
Construction/Loadline › Structures › Door
Issued 26 July 2005 Resolved
Replace exterior door framing on the astern.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 1 September 2005
Resolved 20 November 2006
Fire Fighting › Fire Pumps › Pressure
Issued 31 January 2005 Resolved
Prove proper operation of fire main system. Pump would not draw suction or discharge sufficient pressure.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 8 February 2005
Resolution: Conducted test of fire main system all sat
Fire Fighting › Structural - A Class Divisions › Machinery Spaces
Issued 31 January 2005 Resolved
Replace structural fire protection insulation in overhead over starboard main engine.
Condition: Improper Installation
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 4 February 2005
Resolution: USCG-approved structural fire protection insulation installed over starboard engine per 46CFR116.415.
Operations/Management › Drills/Instruction › Fire
Issued 31 January 2005 Resolved
Conduct satisfactory fire drill to verify that new hires can work together and are knowledgable with the vessel's fire plan.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 4 February 2005
Resolution: Conducted satisfactory fire drill: Class "C" fire in Galley using JACMS smoke generator and charged hoses secured at the hydrant valve.
Lifesaving › Inflatable Liferafts › Servicing
Issued 31 January 2005 Resolved
Provide inflatable liferafts and hydrostatic release units that are current in their inspection cycle. The inspection cycle of all 3 of vessel's liferafts and release units has expired.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 4 February 2005
Resolution: Verified USCG-approved facility inspection and servicing stamps on all of vessel''''s liferafts and hydrostatic release units, servicing receipts, including equipment provisions, and proper installation of liferafts and hydrostatic release units.
Electrical › Lighting (emergency) › Lighting Branch Circuit
Issued 31 January 2005 Resolved
Prove proper operation of all emergency lighting throughout vessel.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 4 February 2005
Resolution: Placed emergency lighting system on-line and witnessed proper operation of all branch circuits.
Accommodation/Occupational Safety › Medical/First Aid › Medicine Chest
Issued 31 January 2005 Resolved
Provide proper First Aid Kit per 46CFR121.710.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 4 February 2005
Resolution: Verified contents of equivalent First Aid Kit in watertight container properly marked "First-Aid Kit."
Communications › Audible Communications › SPD (Other)
Issued 31 January 2005 Resolved
Prove proper operation of Public Address system. Post Emergency Broadcast placard.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 4 February 2005
Resolution: Witnessed satisfactory operation of Public Address system. Located emergency broadcast placard detailing standard emergency broadcasts.
Documentation › Logs/Records › Logbook/Record (unofficial)
Issued 31 January 2005 Resolved
Provide current crew training log book, lifesaving equipment maintenance record, and test of internal communications.
Action required: 705 - Other - as specified
Due 15 March 2005
Resolved 16 February 2005
Resolution: Witnessed by Marine Inspector.
Documentation › Manuals/Policy Documentation › Emergency Instructions
Issued 31 January 2005 Resolved
Provide emergency evacuation plan.
Action required: 705 - Other - as specified
Due 15 March 2005
Resolved 21 March 2005
Documentation › Safety/Response Plans/Programs › Fire Control Plans
Issued 31 January 2005 Resolved
Provide fire control plan.
Action required: 705 - Other - as specified
Due 15 March 2005
Resolved 21 March 2005
Construction/Loadline › Structures › Door
Issued 31 January 2005 Resolved
Remove foam insulation around aft main deck tonnage door.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 5 March 2005
Resolved 1 March 2005
Electrical › Electrical Distribution System (service) › Cable
Issued 31 January 2005 Resolved
Replace elect cover on junction box stbd side after wheel house
Due 28 February 2005
Resolved 16 February 2005
Resolution: Witnessed by Marine Inspector.
Electrical › Lighting (service) › Lighting Fixture
Issued 31 January 2005 Resolved
Replace various safety globe through out vesse as marked
Due 28 February 2005
Resolved 4 February 2005
Resolution: checked light all sat
Construction/Loadline › Penetrations › Pipe Flange
Issued 31 January 2005 Resolved
Cap and or replace piping on sewage discharge line stbd side aft,
Due 28 February 2005
Resolved 16 February 2005
Resolution: Witnessed by Marine Inspector.
Electrical › Electric Supply System (service) › Cable
Issued 31 January 2005 Resolved
Locate and remove all house hold screw type wire nut from junction box in vessel.
Due 28 February 2005
Resolved 16 February 2005
Resolution: Witnessed by Marine Inspector.
Electrical › Electrical Distribution System (service) › Circuit Breaker
Issued 31 January 2005 Resolved
Replace breaker or place a blank in breaker panel B 01 deck
Due 28 February 2005
Resolved 4 February 2005
Resolution: Witnessed by Marine Inspector.
Electrical › Electric Supply System (service) › Battery Installation
Issued 31 January 2005 Resolved
Remove all tumb type wing nut's from service batteries
Due 28 February 2005
Resolved 4 February 2005
Resolution: Cleared
Engineering › Diesel Engine (propulsion-reduction gear) › Valve
Issued 31 January 2005 Resolved
Replace various valve hand wheels
Due 28 February 2005
Resolved 16 February 2005
Resolution: Witnessed by Marine Inspector.
Fire Fighting › Fixed CO2 Fire Extinguishing System › Operating Controls
Issued 31 January 2005 Resolved
Paint and label CO2 discharge horn
Due 28 February 2005
Resolved 4 February 2005
Resolution: Witnessed by Marine Inspector.
Fire Fighting › Structural Fire Protection - General › Hull Construction
Issued 31 January 2005 Resolved
Replace fire stop in bulkhead between engine room fwd , & voids space, also replace non-conductive mat in front of SSDG genset
Due 28 February 2005
Resolved 1 March 2005
Documentation › Certificates/Documents › Certificate of Inspection
Issued 14 January 2005 Resolved
SCHEDULE AND MAKE VESSEL AVAILABLE FOR AN ANNUAL INSPECTION PRIOR TO CARRYING PASSENGERS AND PLACING VESSEL BACK IN SERVICE.
Action required: 701 - Prior to carriage of passengers/cargo
Due 12 July 2005
Resolved 31 January 2005
Resolution: JACMS scheduled annual inspection and MTSA compliance examination for 01/31/2005.
Operations/Management › Drug and Alcohol Testing › Employee Coverage
Issued 10 November 2003 Resolved
Provide enrollment letter for DAPI program with employees listed, as per 46CFR part 16.
Due 14 November 2003
Resolved 14 November 2003
Personnel › Certificates/Documents/Licenses › License, Mate
Issued 10 November 2003 Resolved
Provide original Master and Mate licenses, as per 46CFR15.805 & 122.402.
Due 10 November 2003
Resolved 14 November 2003
Operations/Management › Drills/Instruction › Man Overboard Recovery
Issued 10 November 2003 Resolved
Conduct fire drill, man overboard drill, and abandon ship drill, as per NVIC 6-91.
Due 10 November 2003
Resolved 14 November 2003
Lifesaving › Inflatable Liferafts
Issued 10 November 2003 Resolved
Provide annual service report that life rafts have been serviced, as per 46CFR117.130.
Due 10 November 2003
Resolved 14 November 2003
Communications › Radio Communications › EPIRB
Issued 10 November 2003 Resolved
Register EPIRB with current owner, as per 46CFR122.728.
Due 10 November 2003
Resolved 14 November 2003
Fire Fighting › Structural - A Class Divisions › Doors
Issued 10 November 2003 Resolved
Adjust all fire doors so they fully close when released, as per 46CFR116.415.
Due 10 November 2003
Resolved 14 November 2003
Fire Fighting › Combustible Materials › Furniture/Furnishings
Issued 10 November 2003 Resolved
Provide evidence that all newly installed furnishing is fire resistant, as per 46CFR116.423
Due 10 November 2003
Resolved 14 November 2003
Navigation › Piloting/Steering
Issued 10 November 2003 Resolved
Swing compass as per 33CFR164.
Due 10 November 2003
Resolved 14 November 2003
Navigation › Collision/Grounding Avoidance › Navigation Lights
Issued 10 November 2003 Resolved
Install not under command lights, as per COLGRES.
Due 10 November 2003
Resolved 14 November 2003
Electrical › Electric Supply System (service)
Issued 10 November 2003 Resolved
Install blank cover in distribution panel in engine room.
Due 10 November 2003
Resolved 14 November 2003
Electrical › Electric Supply System (service)
Issued 10 November 2003 Resolved
Install non-metallic grab rail on main switchboard.
Due 10 November 2003
Resolved 14 November 2003
Electrical › Electric Supply System (service)
Issued 10 November 2003 Resolved
Install chaffing gear on all wiring and hoses that can chaff on the machinery.
Due 10 November 2003
Resolved 14 November 2003
Electrical › Electric Supply System (service)
Issued 10 November 2003 Resolved
Secure all wiring in engine room.
Due 10 November 2003
Resolved 14 November 2003
Engineering › Bilge Water Management System › Pump
Issued 10 November 2003 Resolved
Move high bilge alarm in engine room to a lower location.
Due 10 November 2003
Resolved 14 November 2003
Electrical › Electric Supply System (service)
Issued 10 November 2003 Resolved
Provide cover for port refrigerator and repair loose wiring.
Due 10 November 2003
Resolved 14 November 2003
Electrical › Electric Supply System (service)
Issued 10 November 2003 Resolved
Provide 6 protective covers for lights in galley.
Due 10 November 2003
Resolved 14 November 2003
Accommodation/Occupational Safety › Cooking Systems
Issued 10 November 2003 Resolved
Mount two tier stove in galley.
Due 10 November 2003
Resolved 14 November 2003
Fire Fighting › Fire Pumps › Pressure
Issued 10 November 2003 Resolved
Repair mechanical fire pump.
Due 10 November 2003
Resolved 14 November 2003
Electrical › Electric Supply System (service)
Issued 10 November 2003 Resolved
Remove extension cord at main deck ATM machine and install a marine cable.
Due 10 November 2003
Resolved 14 November 2003
Accommodation/Occupational Safety › Potable Water System
Issued 10 November 2003 Resolved
Repair potable water pump.
Due 10 November 2003
Resolved 14 November 2003
Stability › Watertight Integrity
Issued 9 July 2003 Resolved
Prior to the completion of your next Annual Inspection, repair all hatch covers as needed. LEGACY COMPONENT DESC: Deck Hatches
Condition: Improper/Lack of Maintenance
Due 9 July 2003
Resolved 10 November 2003
Stability › Weathertight Integrity
Issued 9 July 2003 Resolved
Prior to the completion of your next Annual Inspection, repair/replace all broken windows and wasted window frames as discussed. LEGACY COMPONENT DESC: Windows
Condition: Improper/Lack of Maintenance
Due 9 July 2003
Resolved 10 November 2003
Stability › Weathertight Integrity
Issued 9 July 2003 Resolved
Prior to the completion of your next Annual Inspection, replace pilot house doors and frames as discussed. LEGACY COMPONENT DESC: Pilot house doors
Condition: Improper/Lack of Maintenance
Due 9 July 2003
Resolved 10 November 2003
Stability › Watertight Integrity
Issued 9 July 2003 Resolved
Prior to the completion of your next Annual Inspection, open for inspection, ONLY if water tank is part of the hull. LEGACY COMPONENT DESC: Water tank/hull examination
Condition: Unknown
Due 9 July 2003
Resolved 10 November 2003
Stability › Weathertight Integrity
Issued 9 July 2003 Resolved
Prior to the completion of your next Annual Inspection, replace AFT main deck door frame. LEGACY COMPONENT DESC: AFT main deck door
Condition: Improper/Lack of Maintenance
Due 9 July 2003
Resolved 10 November 2003
Accommodation/Occupational Safety › Occupational Safety
Issued 19 December 2002 Resolved
MAKE TEMPORARY REPAIR TO PORT BOARDING DOOR WINDOW PRIOR TO CARRIAGE OF PASENGERS. MAKE PERMANENT REPAIR PRIOR TO 30DEC02. LEGACY COMPONENT DESC: Windows
Condition: Improper/Lack of Maintenance
Due 30 December 2002
Resolved 10 November 2003
Accommodation/Occupational Safety › Occupational Safety
Issued 19 December 2002 Resolved
MAKE TEMPORARY REPAIR TO AFT STEP PRIOR TO CARRIAGE OF PASSENGERS. MAKE PERMANENT REPAIR PRIOR TO 30DEC02. LEGACY COMPONENT DESC: Steps/ladder
Condition: Improper/Lack of Maintenance
Due 30 December 2002
Resolved 10 November 2003
Accommodation/Occupational Safety › Occupational Safety
Issued 19 December 2002 Resolved
PROPERLY LABEL EMERGENCY ESCAPES. LEGACY COMPONENT DESC: Emergency escape
Condition: Improper Installation
Due 30 December 2002
Resolved 10 November 2003
Electrical › Electrical Distribution System (service)
Issued 19 December 2002 Resolved
PROPERLY INSTALL TRANSDUCER CABLE PRIOR TO CARRIAGE OF PASSENGERS. LEGACY COMPONENT DESC: Wiring
Condition: Unknown
Due 30 December 2002
Resolved 10 November 2003
Engineering › Diesel Engine (propulsion-reduction gear)
Issued 21 October 2002 Resolved
Provide new engine mounts for both P/S MDE's
Condition: Unknown
Action required: 705 - Other - as specified
Due 31 March 2003
Resolved 10 November 2003
Engineering › Diesel Engine (propulsion-direct drive)
Issued 16 October 2002 Resolved
Re-weld broken temp main engine mounts.
Condition: Unknown
Due 6 November 2002
Resolved 7 November 2002
Resolution: Re-welded temp engine mounts.
Engineering › Diesel Engine (propulsion-direct drive)
Issued 16 October 2002 Resolved
Provide documentation on alignment of mains.
Due 30 January 2003
Resolved 19 December 2002
Engineering › Diesel Engine (propulsion-direct drive)
Issued 16 October 2002 Resolved
Provide information on brackets that were added to main engine mounts (print, work order etc...).
Due 21 November 2002
Resolved 25 November 2002
Pollution Prevention/Response
Issued 16 October 2002 Resolved
Remove excessive amounts of oil from engine room bilges.
Due 24 October 2002
Resolved 14 November 2002
Engineering › Generator (propulsion-electric)
Issued 20 August 2002 Resolved
Vessel engineer started noticing high temps on #1 ssg internal winding and notified capt. Capt. decided to leave #1 ssg in an off-line status until further troubleshooting could commence. Upon further troubleshooting, crew determined rotor needed to be re-wound. Issued (1) CG-835 to repair #1ssg. LEGACY COMPONENT DESC: Winding
Condition: Unknown
Due 13 September 2002
Resolved 20 September 2002
Resolution: Resolved. Rewound rotor and tested, all found satisfactory
Lifesaving › Lifejacket/PFD (Type I) › Retroreflective Material
Issued 15 April 2002 Resolved
170 out of 487 lifejackets needed retro replacement.
Condition: Unknown
Due 1 May 2002
Resolved 17 April 2002
Resolution: Replaced retro on 170 jackets.
Lifesaving › Lifejacket/PFD (Type I)
Issued 15 April 2002 Resolved
Fwd main deck lifejacket storage box markings worn/re-paint . LEGACY COMPONENT DESC: Storage
Condition: Unknown
Due 1 May 2002
Resolved 2 May 2002
Resolution: Re-painted boxes.
Lifesaving › Inflatable Liferafts
Issued 15 April 2002 Resolved
Vessel recently installed IBA's. Launching instructions missing. LEGACY COMPONENT DESC: Markings
Condition: Unknown
Due 1 May 2002
Resolved 2 May 2002
Resolution: Installed instructions.
Electrical › Electrical Distribution System (service)
Issued 15 April 2002 Resolved
Dead cable outboard #1 SSG and inboard #2 SSG. Cables need to be removed. LEGACY COMPONENT DESC: Wiring
Condition: Unknown
Due 1 May 2002
Resolved 2 May 2002
Resolution: Engineer removed cables.
Engineering › Diesel Engine (propulsion-direct drive) › Cylinder Head
Issued 31 January 2002 Resolved
Cracked right cylinder head on stbd engine, between #1 and #2 cylinders.
Condition: Unknown
Due 31 January 2002
Resolved 31 January 2002
Resolution: Recd fax from Covington Detroit Diesel mechanic stating new cylinder kits installed for both heads, engine tested sat.
Communications › Alarms/Indicators › Bilge Alarm
Issued 24 October 2001 Resolved
Prove proper operation of all high level bilge alarms.
Due 24 October 2001
Resolved 25 October 2001
Communications › Alarms/Indicators
Issued 24 October 2001 Resolved
Prove proper operation of fire alarm on bridge. LEGACY COMPONENT DESC: Fire Alarm
Due 24 October 2001
Resolved 25 October 2001
Electrical › Electric Supply System (service)
Issued 24 October 2001 Resolved
Prove proper operation of reverse power relay on #2 and #3 main generators. LEGACY COMPONENT DESC: Reverse Current Protection
Due 24 October 2001
Resolved 25 October 2001
Operations/Management › Vessel Safety Management › Plans for Shipboard Operations
Issued 24 October 2001 Resolved
Provide updated fuel management plan for vessel.
Due 24 October 2001
Resolved 31 October 2001
Personnel › Certificates/Documents/Licenses › Certificate, Radar Observer
Issued 24 October 2001 Resolved
Provide proof of valid MROPs for all vsl captains & mates.
Due 24 October 2001
Resolved 30 October 2001
Engineering
Issued 30 August 2001 Resolved
Port main engine #6 cooling injector failed due to normal wear.
Condition: Unknown
Due 30 August 2001
Resolved 6 September 2001
Engineering
Issued 4 June 2001 Resolved
Repair in kind vessel bow thruster.
Condition: Unknown
Due 20 June 2001
Resolved 20 June 2001
Electrical
Issued 15 May 2001 Resolved
MAKE ALL WIRE CONNECTIONS IN OVERHEAD ON BOTH DECKS AS PER 46 CFR 120.340(G).
Condition: Unknown
Due 15 May 2001
Resolved 15 May 2001
Lifesaving
Issued 15 May 2001 Resolved
SECURE PORT WATER LIGHT ON RING BUOY WITH CLIP AS PER 46 CFR 180.70 (D),
Condition: Unknown
Due 15 May 2001
Resolved 15 May 2001
Electrical
Issued 15 May 2001 Resolved
MAKE PERMANENT REPAIRS TO AIR CONDITIONING ELECTRICAL BOX.
Condition: Unknown
Due 15 May 2001
Resolved 15 May 2001
Electrical
Issued 15 May 2001 Resolved
REPLACE RECEPTICAL BOX COVER IN GALLEY.
Condition: Unknown
Due 15 May 2001
Resolved 15 May 2001
Accommodation/Occupational Safety
Issued 15 May 2001 Resolved
PROPERLY STENCIL 'E' ON ALL EMERGENCY LIGHTS.
Condition: Unknown
Due 15 May 2001
Resolved 15 May 2001
Electrical
Issued 15 May 2001 Resolved
FILL BLANKS IN CIRCUIT BREAKER BOXES IN GALLEY.
Condition: Unknown
Due 15 May 2001
Resolved 15 May 2001
Fire Fighting
Issued 15 May 2001 Resolved
ADJUST GALLEY FIRE DOORS.
Condition: Unknown
Due 15 May 2001
Resolved 15 May 2001
Construction/Loadline
Issued 15 May 2001 Resolved
MAKE PROPER REPAIRS TO PORT SEA STRAINER LEAK.
Condition: Unknown
Due 15 May 2001
Resolved 15 May 2001
Engineering
Issued 15 May 2001 Resolved
REMOVE EXCESS OIL AND WATER FROM BILGES.
Condition: Unknown
Due 15 May 2001
Resolved 15 May 2001
Electrical
Issued 15 May 2001 Resolved
MAKE PERMANENT REPAIRS TO #3 GENERATOR EXHAUST.
Condition: Unknown
Due 15 May 2001
Resolved 15 May 2001
Lifesaving
Issued 15 May 2001 Resolved
RENEW/ REPLACE RETROFLECTIVE TAPE ON PFDS AS NEEDED.
Condition: Unknown
Due 15 May 2001
Resolved 15 May 2001
Construction/Loadline
Issued 15 May 2001 Resolved
PROVIDE SEAL AND LOCKING DEVICE FOR BALLAST VOID.
Condition: Unknown
Due 15 May 2001
Resolved 15 May 2001
Accommodation/Occupational Safety
Issued 15 May 2001 Resolved
POST INSTRUCTIONS OF PROPER OPERATION OF ENGINE ROOM CO2 FIRE EXTINGUISHINGSYSTEM.
Condition: Unknown
Due 15 May 2001
Resolved 15 May 2001
Construction/Loadline
Issued 15 May 2001 Resolved
PROVIDE VISUAL ALARMS FOR EACH HIGH LEVEL BILGE ALARM.
Condition: Unknown
Due 15 May 2001
Resolved 15 May 2001
Documentation
Issued 15 May 2001 Resolved
PROVIDE PROOF OF DRUG AND ALCOHOL PROGRAM
Condition: Unknown
Due 15 May 2001
Resolved 15 May 2001
Construction/Loadline
Issued 23 March 2001 Resolved
Complete repairs in Lazarette compartment IWO Port and Starboard rudder tube support stanchions and swash frames.
Condition: Unknown
Due 23 March 2001
Resolved 23 March 2001
Accommodation/Occupational Safety
Issued 29 August 2000 Resolved
Crop and renew wasted metal iwo sewage holding tank at next credit drydock exam.
Condition: Unknown
Due 29 August 2000
Resolved 29 August 2000
Navigation
Issued 29 August 2000 Resolved
Make proper repairs to leaking rudder posts at next credit drydock exam.
Condition: Unknown
Due 29 August 2000
Resolved 29 August 2000
Engineering
Issued 8 May 2000 Resolved
Repair water temp gauge on port generator.
Condition: Unknown
Due 31 May 2000
Resolved 31 May 2000
Fire Fighting
Issued 8 May 2000 Resolved
Clean portable fire extinguisher in engine room - free of oily film.
Condition: Unknown
Due 31 May 2000
Resolved 31 May 2000
Electrical
Issued 8 May 2000 Resolved
Remove dead end cable in stbd side elec control box in engine room.
Condition: Unknown
Due 31 May 2000
Resolved 31 May 2000
Navigation
Issued 8 May 2000 Resolved
Tighten ram foundation bolts on port side steering ram.
Condition: Unknown
Due 31 May 2000
Resolved 31 May 2000
Fire Fighting
Issued 8 May 2000 Resolved
Obtain updated inspection of firefighting system.
Condition: Unknown
Due 9 May 2000
Resolved 31 May 2000
Fire Fighting
Issued 8 May 2000 Resolved
Post new fire control plan for passengers (46 CFR 116.530).
Condition: Unknown
Due 31 May 2000
Resolved 31 May 2000
Documentation
Issued 8 May 2000 Resolved
Provide inspector proof of CPR certification for one additional crewman.
Condition: Unknown
Due 31 May 2000
Resolved 31 May 2000
Lifesaving
Issued 8 May 2000 Resolved
remark two stowage areas for adult lifejackets to show "83" lifejackets.
Condition: Unknown
Due 31 May 2000
Resolved 31 May 2000
Lifesaving
Issued 8 May 2000 Resolved
install new retroreflective tape on first deck ring buoy.
Condition: Unknown
Due 31 May 2000
Resolved 31 May 2000
Construction/Loadline
Issued 8 May 2000 Resolved
Clean all oil & rags from bilge.
Condition: Unknown
Due 31 May 2000
Resolved 31 May 2000
Engineering
Issued 8 May 2000 Resolved
Repair exhaust leak on port engine in way of overhead support near vent blower.
Condition: Unknown
Due 31 May 2000
Resolved 31 May 2000
Lifesaving
Issued 8 May 2000 Resolved
Repair cracks on lifefloats as needed.
Condition: Unknown
Due 31 May 2000
Resolved 31 May 2000
Fire Fighting
Issued 8 May 2000 Resolved
Repair fire door on upper deck so door closes independently.
Condition: Unknown
Due 31 May 2000
Resolved 31 May 2000
Lifesaving
Issued 8 May 2000 Resolved
Replace retroreflective tape on lifejackets as needed.
Condition: Unknown
Due 9 May 2000
Resolved 31 May 2000
Accommodation/Occupational Safety
Issued 8 May 2000 Resolved
Replace overhead metal paneling in area of exhaust leak in engine room.
Condition: Unknown
Due 31 May 2000
Resolved 31 May 2000
Electrical
Issued 8 May 2000 Resolved
Label breaker panel in engine room.
Condition: Unknown
Due 31 May 2000
Resolved 31 May 2000
Construction/Loadline
Issued 8 May 2000 Resolved
Stencil maximum number of passengers on upper deck in way of aft ladder.
Condition: Unknown
Due 31 May 2000
Resolved 31 May 2000
Electrical
Issued 8 May 2000 Resolved
Install cover on electrical junction box in lazarette.
Condition: Unknown
Due 31 May 2000
Resolved 31 May 2000
Accommodation/Occupational Safety
Issued 20 January 2000 Resolved
Repair/replace valves for MSD overboard discharge so they function as new.
Condition: Unknown
Due 20 January 2000
Resolved 20 January 2000
Accommodation/Occupational Safety
Issued 20 January 2000 Resolved
Provide placard on deck in accordance with 33 CFR 159.59 near MSD station on deck.
Condition: Unknown
Due 20 January 2000
Resolved 20 January 2000
Electrical
Issued 13 May 1999 Resolved
Remove zipties in engineroom and surveillance and replace with metal wraps.
Condition: Unknown
Due 25 May 1999
Resolved 20 August 1999
Electrical
Issued 13 May 1999 Resolved
Remove all dead end wiring in engineroom.
Condition: Unknown
Due 25 May 1999
Resolved 20 August 1999
Electrical
Issued 13 May 1999 Resolved
Replace light covers in slot tech room.
Condition: Unknown
Due 25 May 1999
Resolved 20 August 1999
Documentation
Issued 13 May 1999 Resolved
Provide copies (fax) of Emergency Broadcast and 50 percent crew CPR/First Aid cards.
Condition: Unknown
Due 25 May 1999
Resolved 20 August 1999
Documentation
Issued 13 May 1999 Resolved
Renew vessel FCC safety certificate.
Condition: Unknown
Due 25 May 1999
Resolved 20 August 1999
Documentation
Issued 13 May 1999 Resolved
Provide FCC permit for all Captains.
Condition: Unknown
Due 25 May 1999
Resolved 20 August 1999
Electrical
Issued 13 May 1999 Resolved
Provide reverse power protection for all 3 generators, according to 46 CFR 111.12-11(f).
Condition: Unknown
Due 25 May 1999
Resolved 20 August 1999
Engineering
Issued 13 May 1999 Resolved
Replace/repair exhaust lagging wraps.
Condition: Unknown
Due 25 May 1999
Resolved 20 August 1999
Engineering
Issued 13 May 1999 Resolved
Set overspeed trips, all MDE and SSG engines.
Condition: Unknown
Due 25 May 1999
Resolved 20 August 1999
Engineering
Issued 13 May 1999 Resolved
Remove fuel soaked chaffing on engineroom fuel systems.
Condition: Unknown
Due 25 May 1999
Resolved 20 August 1999
Fire Fighting
Issued 13 May 1999 Resolved
Replace one 50 foot fire hose.
Condition: Unknown
Due 25 May 1999
Resolved 20 August 1999
Electrical
Issued 13 May 1999 Resolved
Install emergency lights in galley (repair), slot tech, fwd slots main deck, main deck cage, 1st deck bar area.
Condition: Unknown
Due 25 May 1999
Resolved 20 August 1999
Accommodation/Occupational Safety
Issued 5 April 1999 Resolved
Remove false overhead, including grillwork and brackets, from slot tech spaces, preventing accumulation of flammable materials and the chance of ceiling falling on personnel.
Condition: Unknown
Due 5 April 1999
Resolved 19 August 1999
Accommodation/Occupational Safety
Issued 17 March 1999 Resolved
Housekeeping general, remove or prevent accumulation of trash behind slot machines and cash cage 01 deck.
Condition: Unknown
Due 5 April 1999
Resolved 20 August 1999
Electrical
Issued 17 March 1999 Resolved
Rewire surveillance room so that surge suppressors are plugged into permanent outlets and not each other.
Condition: Unknown
Due 5 April 1999
Resolved 20 August 1999
Lifesaving
Issued 17 March 1999 Resolved
Provide and mount bracket for waterlight, portside bridge.
Condition: Unknown
Due 5 April 1999
Resolved 20 August 1999
Accommodation/Occupational Safety
Issued 17 March 1999 Resolved
Open aisles on main deck forward between slot machines so that a 30 inch aisle exists in accordance with 46 CFR 116.820(d)(2).
Condition: Unknown
Due 5 April 1999
Resolved 20 August 1999
Accommodation/Occupational Safety
Issued 17 March 1999 Resolved
Open black jack tables so that two 24 inch egress routes exist from behind tables for employees on 01 deck aft, without reducing passenger aisles.
Condition: Unknown
Due 5 April 1999
Resolved 20 August 1999
Electrical
Issued 17 March 1999 Resolved
Remove extension cord from ATM machine 01 deck.
Condition: Unknown
Due 5 April 1999
Resolved 20 August 1999
Engineering
Issued 2 February 1999 Resolved
Repair or replace starboard propeller due to fractures in trailing edges ofall four blades.
Condition: Unknown
Due 5 February 1999
Resolved 5 February 1999
Documentation
Issued 21 January 1999 Resolved
Vessel is required to conduct a deadweight survey prior to issuing vessels permanent stability letter.
Condition: Unknown
Due 21 January 1999
Resolved 21 January 1999
Fire Fighting
Issued 21 January 1999 Resolved
Provide servicing report for fixed fire fighting system in galley.
Condition: Unknown
Due 11 February 1999
Resolved 11 February 1999
Fire Fighting
Issued 21 January 1999 Resolved
Remove excess fire pull, forward port side in galley.
Condition: Unknown
Due 11 February 1999
Resolved 11 February 1999
Electrical
Issued 21 January 1999 Resolved
Ensure all covers to electrical panels are secure, specifically in galley.
Condition: Unknown
Due 11 February 1999
Resolved 11 February 1999
Documentation
Issued 21 January 1999 Resolved
Demonstrate ability of designated deckhand/mate to maneuver vessel safely back to the dock.
Condition: Unknown
Due 11 February 1999
Resolved 11 February 1999
Electrical
Issued 21 January 1999 Resolved
Remove all dead end wiring throughout vessel, specifically in galley.
Condition: Unknown
Due 11 February 1999
Resolved 11 February 1999
Accommodation/Occupational Safety
Issued 21 January 1999 Resolved
Label emergency escape hatch from engineroom and galley.
Condition: Unknown
Due 11 February 1999
Resolved 11 February 1999
Lifesaving
Issued 21 January 1999 Resolved
Donning instructions for lifejackets shall be posted at muster stations.
Condition: Unknown
Due 11 February 1999
Resolved 11 February 1999
Lifesaving
Issued 21 January 1999 Resolved
Replace batteries for waterlights in life floats.
Condition: Unknown
Due 11 February 1999
Resolved 11 February 1999
Fire Fighting
Issued 13 May 1996 Resolved
INSTALL MEANS OF LATCHING GALLEY DOORS CLOSED._x001C_ _x001C_ _x001C_ _x001C_
Condition: Unknown
Due 20 May 1996
Resolved 24 June 1996
Fire Fighting
Issued 13 May 1996 Resolved
ADJUST DOOR CLOSERS AND REPAIR LATCHES ON INTERIOR DOORS FROM 1ST TO 2ND DECK._x001C_ _x001C_ _x001C_
Condition: Unknown
Due 20 May 1996
Resolved 24 June 1996
Accommodation/Occupational Safety
Issued 13 May 1996 Resolved
RENEW GLASSES IN SEVERAL WEATHERDECK DOORS.
Condition: Unknown
Due 28 June 1996
Resolved 26 August 1996
Lifesaving
Issued 13 May 1996 Resolved
PRIOR TO CARRYING PASSENGERS, PROVIDE 6 ORANGE SMOKE FLARES._x001C_ _x001C_ _x001C_ _x001C_
Condition: Unknown
Due 20 May 1996
Resolved 24 June 1996
Fire Fighting
Issued 13 May 1996 Resolved
PRIOR TO CARRYING PASSENGERS, PROVIDE 1 50' FIRE HOSE._x001C_ _x001C_ _x001C_ _x001C_
Condition: Unknown
Due 20 June 1996
Resolved 24 June 1996
Accommodation/Occupational Safety
Issued 13 May 1996 Resolved
LABEL AFT STAIR FROM 2ND TO 3RD DECK 275 PERSONS MAXIMUM._x001C_ _x001C_ _x001C_ _x001C_
Condition: Unknown
Due 20 May 1996
Resolved 24 June 1996
Lifesaving
Issued 13 May 1996 Resolved
LABEL FLARE BOX DISTRESS SIGNALS._x001C_ _x001C_ _x001C_ _x001C_
Condition: Unknown
Due 20 May 1996
Resolved 24 June 1996
Accommodation/Occupational Safety
Issued 13 May 1996 Resolved
REPAIR/REPLACE DETERIORATED WEATHERDECK DOORS AFT MAIN DECK AND THE 2 FWD DOORS ON THE 2ND DECK._x001C_ _x001C_ _x001C_
Condition: Unknown
Due 13 May 1996
Resolved 13 May 1996
Lifesaving
Issued 23 May 1995 Resolved
PROVIDE 43 ADULT USCG APPROVED TYPE I LIFE PRESERVERS. VESSEL RESTRICTED TOA MAXIMUM OF 517 TOTAL PERSONS ONBOARD UNTIL THIS REQUIREMENT IS MET.
Condition: Unknown
Due 26 May 1995
Resolved 26 May 1995
Fire Fighting
Issued 23 May 1995 Resolved
PROVIDE ONE REPLACEMENT FIRE HOSE FOR FIRE STATION NO. 3. THIS REQUIREMENT TO BE MET PRIOR TO CARRIAGE OF PASSENGERS.
Condition: Unknown
Due 26 May 1995
Resolved 26 May 1995
Navigation
Issued 23 May 1995 Resolved
PROVIDE CURRENT NAVIGATION CHARTS FOR JACMS AREA OF OPERATION.
Condition: Unknown
Due 26 May 1995
Resolved 26 May 1995
Navigation
Issued 23 May 1995 Resolved
PROVIDE CURRENT COPY OF TIDE TABLES.
Condition: Unknown
Due 26 May 1995
Resolved 26 May 1995
Electrical
Issued 23 May 1995 Resolved
PROPERLY REMARK ELECTRICAL BREAKERS AND ATTACH CLOSURE MECHANISM TO DOOR OFFORWARD PORT DISTRIBUTION PANEL IN GALLEY.
Condition: Unknown
Due 26 May 1995
Resolved 26 May 1995
Accommodation/Occupational Safety
Issued 25 May 1994 Resolved
INSTALL FLAME SCREENS TO MSD TANK VENTS.
Condition: Unknown
Due 25 May 1994
Resolved 25 May 1994
Documentation
Issued 25 June 1993 Resolved
PROVIDE AND POST STABILITY LETTER BASED ON RESULTS OF 22JUN93 STABILITY TEST. VESSEL IS PROHIBITED FROM CARRYING PASSENGERS UNTIL SATISFACTORY COMPLETION OF THIS REQUIREMENT.
Condition: Unknown
Due 25 June 1993
Resolved 25 June 1993
Electrical
Issued 25 June 1993 Resolved
COMPLETE AND INSTALL ALL NEW WIRING FOR CASINO OPERATION TO THE SATISFACTION OF COAST GUARD MARINE INSPECTOR. THIS REQUIRMENET TO BE COMPLETED PRIOR TO THE CARRIAGE OF ANY PASSENGERS.
Condition: Unknown
Due 25 June 1993
Resolved 25 June 1993
Deck/Cargo
Issued 25 June 1993 Resolved
PERFORM OPERATIONAL TEST OF BOW THRUSTER IN PRESENCE OF CG MARINE INSPECTOR.
Condition: Unknown
Due 25 June 1993
Resolved 25 June 1993
Fire Fighting
Issued 25 June 1993 Resolved
PERFORM OPERATIONAL TEST OF REMOTE VENTILATION SHUTDOWNS. TEST TO BE CONDUCTED IN PRESENCE OF CG MARINE INSPECTOR.
Condition: Unknown
Due 25 June 1993
Resolved 25 June 1993
Electrical
Issued 25 June 1993 Resolved
PERFORM TEST OF PARALLEL OPERATION OF #1 AND #2 GENERATORS. TEST REVERSE CURRENT RELAYS. PERFORM TEST IN PRESENCE OF CG INSPECTOR. TEST TO BE CONDUCTED PRIOR TO CARRYING PASSENGERS.
Condition: Unknown
Due 25 June 1993
Resolved 25 June 1993
Electrical
Issued 25 June 1993 Resolved
PERFORM OPERATIONAL TEST OF #3 GENERATOR UNDER LOAD. PERFORM TEST OF REVERSE CURRENT RELAYS. TESTS TO BE CONDUCTED IN PRESENCE OF AND TO SATISFACTION OF CG MARINE INSPECTOR.
Condition: Unknown
Due 25 June 1993
Resolved 25 June 1993
Accommodation/Occupational Safety
Issued 25 June 1993 Resolved
THE SPACE BELOW THE RAILING ON THE UPPERMOST DECK IS TO BE FITTED WITH BULWARKS CHAIN LINK FENCING, WIRE MESH OR EQUIVALENT IN ACCORDANCE WITH 46CFR177.35-1(C). PASSENGERS ARE NOT PERMITTED ON UPPER DECK UNTIL SATISFACTORY COMPLETION OF THIS REQUIREMENT.
Condition: Unknown
Due 25 June 1993
Resolved 25 June 1993
Engineering
Issued 25 June 1993 Resolved
FABRICATE AND INSTALL NEW COOLING WATER PIPING FOR #3 GENERATOR. PIPE IS 11/2" BRASS RUNNING FROM RAW WATER PUMP TO HEAT EXCHANGER.
Condition: Unknown
Due 25 June 1993
Resolved 25 June 1993
Documentation
Issued 25 June 1993 Resolved
PROVIDE THE LOCAL CG MARINE INSPECTION OFFICE WITH AN APPROVED COPY OF ELECTRICAL PLANS AND STRUCTURAL FIRE PROTECTION PLANS.
Condition: Unknown
Due 25 June 1993
Resolved 25 June 1993
Documentation
Issued 25 June 1993 Resolved
PROVIDE AND POST FCC SAFETY INSTALLATION CERTIFICATE. VESSEL IS RESTRICTEDTO NOT MORE THAN 1000 FEET FROM SHORE WHEN CARRYING PASSENGERS UNTIL SATISFACTORY COMPLETION OF THIS REQUIREMENT.
Condition: Unknown
Due 25 June 1993
Resolved 25 June 1993
Accommodation/Occupational Safety
Issued 5 April 1990 Resolved
PROVE PROPER OPERATION OF VENTILATION SYSTEM REMOTE SHUTDOWNS.
Condition: Unknown
Due 5 April 1990
Resolved 5 April 1990
Fire Fighting
Issued 5 April 1990 Resolved
REPLACE NOZZLE CHAIN ON A.P. NOZZLE AT FIRE STATION #3.
Condition: Unknown
Due 5 April 1990
Resolved 5 April 1990
Fire Fighting
Issued 5 April 1990 Resolved
REPAIR LEAKY HOSE END COUPLING ON FIRE HOSE AT FIRE STATION #1, OR INSTALL NEW HOSE.
Condition: Unknown
Due 5 April 1990
Resolved 5 April 1990
Lifesaving
Issued 5 April 1990 Resolved
REPLACE 3 EACH MISSING ADULT PFD'S NOT LATER THAN 12APR90. A TOTAL OF 588 PERSONS MAY BE CARRIED OUT UNTIL 3 EACH MISSING PFD'S ARE INSPECTED AND STAMPED BY THE ATTENDING USCG INSPECTOR.
Condition: Unknown
Due 5 April 1990
Resolved 5 April 1990
Fire Fighting
Issued 18 April 1989 Resolved
INSTALL REMOTE RELEASES FOR 2ND DECK FIRE DOORS NOT LATER THAN COMPLIANCE DATE.
Condition: Unknown
Due 18 April 1989
Resolved 18 April 1989
Fire Fighting
Issued 18 April 1989 Resolved
REPLACE 50' SECTION OF 1.5" FIRE HOSE AT UPPER DECK FIRE STATION PRIOR TO GETTING UNDER WAY WITH PASSENGERS BUT NOT LATER THAN COMPLIANCE DATE.
Condition: Unknown
Due 18 April 1989
Resolved 18 April 1989
Fire Fighting
Issued 26 April 1988 Resolved
REPAIR AS ORIGINAL THE DEFECTIVE FIREHOSE PRIOR TO CARRYING PASSENGERS.
Condition: Unknown
Due 26 April 1988
Resolved 26 April 1988
Lifesaving
Issued 26 April 1988 Resolved
RENEW AS ORIGINAL THE LIFELINES ON ALL LIFE RINGS ON BOARD OR RENEW EACH ,LIFE RING.
Condition: Unknown
Due 26 April 1988
Resolved 26 April 1988
Lifesaving
Issued 26 April 1988 Resolved
ON FLOATLIGHTS ATTACHED TO THE 15 BUOYANT APPARATUSES AND ON FLOATLIGHTS ATTACHED TO RING BUOY, REMOVE BATTERIES AND REPLACE WITH CURRENT DATED BATTERIES.
Condition: Unknown
Due 26 April 1988
Resolved 26 April 1988
Lifesaving
Issued 26 April 1988 Resolved
RENEW AS ORIGINAL THE LIFELINES ON ALL 15 BUOYANT APPARATUSES.
Condition: Unknown
Due 26 April 1988
Resolved 26 April 1988
Lifesaving
Issued 27 April 1987 Resolved
VESSEL IS RESTRICTED TO 586 ADULTS ON BOARD UNTIL AN ADDITIONAL FIVE (5) ADULT PERSONAL FLOTATION DEVICES ARE INSPECTED AND APPROVED.
Condition: Unknown
Due 27 April 1987
Resolved 27 April 1987
Accommodation/Occupational Safety
Issued 30 April 1986 Resolved
GOUGE AND REWELD CRACKED WELDS ON THE FWD SIDE OF THE POTABLE WATER TANK INWAY OF THE VERTICAL EXTERNAL FRAMING. WELD TRANSVERSE FRAMING IN WAY OF BOTTOM PLATING PORT & STBD.TO BE COMPLETED PRIOR TO REFILLING TANK, AND/OR CARRYING PASSENGERS,BUT IN ANY CASE, NO LATER THAN THE COMPLIANCE DATE.
Condition: Unknown
Due 30 April 1986
Resolved 30 April 1986
Lifesaving
Issued 30 April 1986 Resolved
STENCIL LIFEFLOAT PADDLES WITH NAME OF VESSEL PRIOR TO COMPLIANCE DATE.
Condition: Unknown
Due 30 April 1986
Resolved 30 April 1986
Fire Fighting
Issued 3 April 1985 Resolved
RENEW GAUGE ON FIRE PUMP AND DEMONSTRATE PROPER OPERATION OF GAUGE.
Condition: Unknown
Due 3 April 1985
Resolved 3 April 1985
Fire Fighting
Issued 3 April 1985 Resolved
SHORTEN THE HASP ON THE PORT GALLEY DOOR TO PREVENT WEDGING THE DOOR IN THE OPEN PORTION.
Condition: Unknown
Due 3 April 1985
Resolved 3 April 1985
Fire Fighting
Issued 3 April 1985 Resolved
INSULATE THE ENGINEROOM HATCH TO AN A-60 STANDARD(EQUAL TO OVERHEAD IN ENGINEROOM).
Condition: Unknown
Due 3 April 1985
Resolved 3 April 1985
Lifesaving
Issued 3 April 1985 Resolved
PROVIDE A CLASS "C" EPIRB PRIOR TO CARRYING PASSENGERS. (VESSEL HAS A "B" EPIRB)
Condition: Unknown
Due 3 April 1985
Resolved 3 April 1985
Lifesaving
Issued 3 April 1985 Resolved
PROVIDE TWO (2) ADDITIONAL ADULT PFD'S FOR A TOTAL 599. VESSEL IS LIMITED TO 597 PERSONS UNTIL THIS REQUIREMENT IS COMPLETED.
Condition: Unknown
Due 3 April 1985
Resolved 3 April 1985

Casualty record · 3

15 June 2002Routine · role: Involved in a Marine Casualty · 1 dead · activity 1634267
1 January 2004Routine · role: Involved in a Marine Casualty · 1 injured · activity 2024099
25 October 2006Routine · role: Involved in a Marine Casualty · activity 2807683
Each line is an incident investigation the Coast Guard recorded with this hull among the vessels involved, with the date and the classification the Coast Guard gave it, and the bridge, lock or dam the investigation names where it names one. Involvement is not fault. The investigation narrative is not published. Source: IIR, through 2026.

Recorded names · 3

STARDANCER (2002), PROGRESSIVE (2004), MV PROGRESSIVE (2006). Names as the Coast Guard recorded them in incident records, with the years they appear; some are renames and some are spelling variants.

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.